Report (13) • if ® cir offrommis Real-World Geotechnical Solutions Investigation• Design•Construction Support October 13, 2015 Project No. 12-2704 Stonebridge Project No. 1840 Stonebridge Homes /‘%4T-2-€ l5- �'�7®5 4230 SW Galewood St., Ste. 100 Lake Oswego, OR 97035 Fax 503-387-7615 Email Andy @stonebridgehomesnw.com; Jim DOstonebridgehomesnw.com; kristen(rdmhholdingsco.corn RE: FOUNDATION EXCAVATION REVIEW SOUTH VIEW SUBDIVISION LOT 3 15180 HARVEY'S VIEW LANE TIGARD, OREGON References: GeoPacific Engineering, Inc., Geotechnical Explorations, Knauss Property Subdivision, 12035 Southwest Beef Bend Road, Washington County, Oregon, report dated August 10, 2012. GeoPacific Engineering Inc. visited the site on yesterday to review the single family home foundation layout on Lot 3. We understand that the proposed building is a two-story home. In our opinion, the observed subgrade is generally adequate for support to an allowable bearing pressure of 1,500 psf. The expected maximum anticipated total and differential footing movements (generally from soil expansion and/or settlement) are 1 inch and 3/4 inch, respectively, over a span of 20 feet. At the time of our site visit, the excavation was nearly complete. The excavation consisted of predominantly medium dense to dense, rocky fill soil that could be probed less than 4 inches with heavy pressure using a steel "T" bar probe. These soils are considered adequate to support the planned foundation loads. Footing-to-slope setbacks were adequate. Some structural backfilling may be required. Due to rocky and silty soils encountered throughout the site, all foundations should incorporate appropriate drainage measures. Crawlspaces should be provided with a low-point drain and pass through pipes should be installed through footings which would otherwise restrict water flow to the low-point drain. Care should be taken to avoid saturation or disturbance of footing subgrade soils during and after excavation. If footing bearing soils become saturated or disturbed, any softened soil or slough should be removed and replaced with crushed aggregate or additional concrete. 14835 SW 72nd Avenue Tel (503)598-8445 Portland, Oregon 97224 Fax (503)941-9281 {., Project No. 12-2704 South View Lot 3 Our work scope pertains to a geotechnical engineer's foundation excavation review only and the conditions existing and exposed at the time of our site visit. Within the limitations of scope, schedule and budget, GeoPacific attempted to execute these services in accordance with generally accepted professional principles and practices in the fields of geotechnical engineering and engineering geology at the time the report was prepared. No warranty, express or implied, is made. If you have any questions, please call. Sincerely, GEOPACIFIC ENGINEERING, INC. -e 0RROI �� ; GIN�F� !o Q 14 E// ORE ON MFS D.0.'3 EXPIRES:06/30/2017 James D. Imbrie, P.E., G.E. Geotechnical Engineer -2-