Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
2T Project: -Untitled87 12/19/2014 Prepared By: 01:30PM tECEIVEP DEC 3 0 2014 2T MY Y OF fIGARD BUILDING DIVISION Tag Cover Sheet - Unit Report 9_ -��' c) Certified Drawing Performance Report 3--(-7 -1-012: 4"1- -- —1-0 Unit Feature Sheet CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: [-r OTC: [ ] Permit#: ME,c-2.0 Address: f CI(7C)l.R.1 Suite#: R-3 By 1 Date: OFFICE COPY Packaged Rooftop Builder 1.39m Page 1 of 7 Unit Report For 2T Project: -Untitled87 12/19/2014 Prepared By: 01:30PM Unit Parameters Dimensions(ft. in.)&Weight(1b.)*** Unit Model: 48ES-A240403 Unit Length 4' 0.1875" Unit Size: 24 (2 Tons) Unit Width" 2' 8.625" Volts-Phase-Hertz:_____..._........ ........... Unit Height 3'4" Heating Type" Gas "'" Weights and Dimensions are approximate.Weight does not include roof Duct Cfg. Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory installed options. Approximate dimensions are provided primarily for 40,000 Btuh shipping purposes.For exact dimensions and weights,refer to appropriate Standard Unit product data catalog. Total Operating Weight: 311 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48ES-A240403 Rooftop Unit 1 Base Unit Accessories CPHSTART002A00 Compressor Hard Start Kit 1 CPCRKHTR008A00 240V Crankcase Heater 1 $3KALlV O3 8Q43 Boa UaWaWVaJI I I :l roiggA [ :3TO tiffrioci tea,ibb.A ssiu2 , Packaged Rooftop Builder 1.39m Page 2 of 7 1 Certified Drawing for 2T Project: -Untitled87 12/19/2014 Prepared By: 01:30PM UNITED P 0.NOV 40011 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION SRNI6410M OF THESE DAARINGS 0A DOCOMENTS TECHNOLOGIES SYRACUSE.NT AND IS DELIYUA[D UPON TT DEPRESS CONDITION THAT TIE DOES NOT CONSTITRTE PART PERfgIMANCE OR CARRIER T3771 CONTORTS NIIL NOT OE DISCLOSED OA REED R[TNOUL CURE/SP ACCEPTANCE Of CONTRACT. CORPORATION'S WRITTEN COMM. UNIT ELECTRICAL UNIT AT UNIT HEIGHT IN/MM CENTER OF GRAVITY IN/MN CHARACTERISTICS LB NG 'A" A Y 2 48ES1-/N1824f040/060130 208/230-1-60 304 137.8 40-1/8 1019 22-13/16 579.4 15-5/16 388.9 15-11/16 398.5 9-15/16 21-9716 9-15/76 4BES1-/N)A301040/0601(3/5)0 208/230-1, 208/230-3-60 309 140.0 42-1/8 1070 22-13/16 579.4 15-5/16 388.9 15.13/16 401.6 1252.41 1511.11 [252-41 48ES(-/N)A36(060I0901(3/5)0 208/230-1. 208/230-3-60 319 144.6 46-1/8 1172 22-13/16 579.4 15-5/16 388.9 15-5/8 422-3 3-7/16- 48ES1-/N14361060/090/60 460-3-60 333 150.9 46-1/6 1172 i.2-13/16 579.4_ 5-5/16 388.9_ 16-5/8 422.3 87.31 1111 lir CORNER WEIGHT LB/N6 UNITS VOLTAGE [601A[®CLEAR/KM 1Y)COMBUSTS/MAIL 2-3// RE7UR4 AI SI7FFLY INCHES 1MM] [69.91 © 48E51-/NI4244040/060130 208/230 45.6 20.7 60.8 21.6 91.1 41.4 106.3 48.3 TOP OF UNIT 11[355 67 48ES(-/N/A30(040/060113/5)0 208/230 46.3 21.0 61.8 28.0 92.6 42.1 108.1 49.1 DUCT SIDE OF UNIT 2[50.87 SIDE OPPOSITE DUCTS 14 1355.61 .�:- �. 48ESt-/N1A361060/090)13/5)0 208/230 47.8 21 7 63.8 28.9 95.6 43.4 111.6 50.6 BOTTOM OF UNIT 0 00.01 Y' �4 48E5(-/41436(060/090160 460 47.8 21,7 63.8 28.9104.647.5 116.6 52.9 FLUE PANEL 36 1914.41 OPTIONAL / \1 OPTIONAL 15-15/16 A[AURN �� ���, SUPPLY Et ILIIIAIL� [-15/1 OP ENIVG/3 \\,�,T INCHES[NMI /[ '- \ \Ty'EING NOTE. ALL TABLE DATA RELEVANT FOR ALL FACTORY INSTALLED BETWEEN UNITS,POWER ENTRY SIDE 42(1066.87 /, 4 \ ' 11 OPTIONS EXCEPT ECONOMIZER UNIT AND UNGROUNDED SURFACES,POWER ENTRY SIDE 36[914.01 !IIIil���I��IIIII Ii '161�11��!1M, UNIT AND BLOCK OR CONCRETE WALLS AND OTHER 1�1,�, 1\,ll'T �� VIII INII GROUNDED SURFACES,POWER ENTRY SIDE 42[1066.81 ,��\\\�� /'�7/1/ 3-3/16 \\\\� /�/ ( _1(81.0i [�M®F]EMRILE FOR OPFAATIM NO SERVCI I OUTDOOR COIL 1�\� =��I�� ■1 EVAP COIL ACCESS SIDE INCHES 6 1914 01 A�u,N [ - A POWER ENTRY BIDE 42(1066.83 I_�.:�W�__,P��' (EXCEPT FOR NEC REOUIREMENTSI UNIT TOP 48 1121 + , SIDE OPPOSITE DUCTS 36/9149011 El lir © _6 DUCT PANEL 12 1304.814 [152'47 INDOOR Gout •MINIMUM OISTANCES•IF UNIT IS PLACED LESS THAN 12 0304.81 FROM WALL TOP VIEW \--OUTDOOR COIL SYSTEM,THEN SYSTEM PERFORMANCE MAYBE COMPROMISED. DIMENSIONS IN[I ARE IN MN lilt 31-7116 - 1 47 4-1/2 1758.51 (25.41 [1193 81 [114.31 I'm` " 1-1/8' [28.61 DIA. A.O. """"■I ""..111111111 11111111111111111! 278" [22.21 DIA. VO ETRY lllllll1ll11�� 1111111 1111111�✓� - CONTROL ENTRY -'qq .A• •■ F1103.81 1 �,,aA.�e��1� 1 ,����]� 15-7/8 SUPPLY RETURN • 1 ®L'd I40�'2I OPENING OPENING 11 MI E LA i 19-15/t6 v 3.5/8 [506.17 t1-5/16 'Z' IS-518 _ [92.11 [363.51 1396.9]10-3/76 • 1258.87 1 - 6-9/16 4 N • '0r-i i�0•I Ma- � °A pilaw _ I -"O• [16,6.71 N00 I I I I 00] DRAIN OUTLET COMPRESSOR 311' [19.0]N.P.T. 12-13/16 PANEL PAR 1 -13/16 1/2" [12.71N.P.7. N 7/8'122.01 DEEP 1023.17 N LECTR[CAl !16.01 I GAS ENTRY 3-7/16 (87.31 ACCESS PANEL 32-5/8 18-3/16 2-1/16 3/16 1828.7] 17224.01 [52./I [4.01 9-1/8 ••-21-5/8 9-7/8 4-13/16 [250.81 1549.31 1250.81 VIEW [112.21 LEFT SIDE VIEW RIGHT SIDE VIEW REAR VIEW NAT[ 4UPFPCEO[6 SINGLE ZONE ELECTRIC COOLING WITH GAS REHEAT (SKI 48ES500214 REV 07/24/09 - 3. 0 Packaged Rooftop Builder 1.39m Page 3 of 7 Performance Summary For 2T Project: -Untitled87 12/19/2014 Prepared By: 01:30PM Part Number:48ES-A240403 ARI SEER:__ _ 13.20 Base Unit Dimensions Unit Length' 48.2 in Unit Width. 32.6 in Unit Height 40.0 in Total Operating Weight 311 lb Unit Unit Voltage-Phase-Hertz' 208-1-60 Air Discharge' Vertical Fan Drive Type' Direct Actual Airflow' 971 CFM Site Altitude' 0 ft Cooling Performance Condenser Entering Air DB' 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB' 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB- 62.4 F Evaporator Leaving Air WB• 59.5 F Evaporator Leaving Air Enthalpy 26.04 BTU/lb Net Cooling Capacity. 23.59 MBH Net Sensible Capacity' 18.46 MBH Total Unit Power Input 2.12 kW Coil Bypass Factor: 0.114 Heating Performance Heating Airflow. 971 CFM Entering Air Temp' 70.0 F Leaving Air Temp' 100.5 F Gas Input Capacity' 40.0 MBH Gas Heating Capacity' 32.00 MBH Temperature Rise' 30.5 F Supply Fan External Static Pressure. 0.50 in wg Options/Accessories Static Pressure Wet Coil: 0.04 in wg Total External Static' 0.54 in wg Fan RPM' 1050 Fan Power 0.31 BHP Fan Motor Size,hp' 1/2 NOTE High Motor Speed,Vert Electrical Data Minimum Voltage. 187 Maximum Voltage. 253 Compressor RLA' 12.8 Compressor LRA' 58.3 Outdoor Fan FLA(ea)' 1.2 Indoor Fan Motor FLA' 4.1 Power Supply MCA' 21.3 Power Supply MOCP(Fuse or HACR)' 30 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Packaged Rooftop Builder 1.39m Page 4 of 7 r Performance Summary For 2T Project: -Untitled87 12/19/2014 Prepared By: 01:30PM Sound Rating 76.0 db Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 66.0 250 Hz NA NA 66.0 500 Hz NA NA 70.5 1000 Hz NA NA 71.5 2000 Hz NA NA 67.5 4000 Hz NA NA 62.5 8000 Hz NA NA 58.5 Advanced Acoustics 1 • Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground- 5.7 ft 4. Height of obstruction:. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 66.0 66.0 70.5 71.5 67.5 62.5 58.5 76.2 Lw B - 49.9 57.4 67.3 71.5 68.7 63.5 57.4 74.8 LwA 26.2 C 0.0 33.6 33.6 38.1 39.1 35.1 30.1 26.1 43.8 Lp D - 17.5 25.0 34.9 39.1 36.3 31.1 25.0 42.4 LpA 26.2 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate Packaged Rooftop Builder 1.39m Page 5 of 7 Performance Summary For 2T Project: -Untitled87 12/19/2014 Prepared By: 01:30PM an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.39m Page 6 of 7 Unit Feature Sheet for 2T Project: - Untitled87 12/19/2014 Prepared By: 01:30PM There is no Certified Drawing available for this tag Packaged Rooftop Builder 1.39m Page 7 of 7