Specifications i1%E'2otr-oc,6.?7 I•zo 7k 54) GareecG, Pi. 7650 S. W.Beveland St. TM RIPPEY Tigard, Oregon 97223 ILA Phone: (503)443-3900 CONSULTING ENGINEERS Fax: (503)443-3700 STRUCTURAL CALCULATIONS PROJECT: 12078 SW GARDEN PL. —RTU LOCATION: TIGARD,OREGON CLIENT: WILLAMETTE HVAC DATE: OCTOBER 1,2015 PROJECT NUMBER: 15260 TABLE OF CONTENTS: ITEM SHEET NUMBER GENERAL NOTES N1 DETAIL SK1-SK3 CALCULATIONS Cl-C3 DESCRIPTION: THIS DESIGN PACKAGE INCLUDES SKETCHES AND CALCULATIONS FOR INSTALLATION OF NEW MECHANICAL RTU AND CURB. SKETCHES PROVIDE ATTACHMENTS OF UNIT TO CURB AND CURB TO EXISTING STRUCTURE. 40PROFt� �` ,�0I N.F te® Ceti w I O N , . . 'c1' s•t97 ° 'y ' `U4 KYLE $ ' GENERAL STRUCTURAL NOTES CODE REQUIREMENTS: CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS AMENDED BY TIIE 2014 OREGON STRUCTURAL SPECIALTY CODE. DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE 2012 INTERNATIONAL BUILDING CODE. IN ADDITION TO THE DEAD LOADS,THE FOLLOWING LOADS WERE USED FOR DESIGN,WITH LIVE LOADS REDUCED PER IBC: RTU MODEL:BRY ANTLEGACY 582J-04A (WT.490 LBS) CURB WEIGHT 94 LBS ROOF LIVE LOAD:25 PSF SNOW BASIC WIND SPEED(3-SEC GUST): 120 MPH(ULT) WIND EXPOSURE:B SEISMIC SITE CLASS:D SDS:0.610 ap:2.5 Rp:6.0 EXISTING CONDITIONS: THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS,DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS PRIOR TO THE START OF THE WORK TEMPORARY CONDITIONS; THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY OF THE NEW AND EXISTING STRUCTURES AND WALLS DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL,CONFIGURATION ONLY. CARPENTRY: SAWN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION,LATEST EDITION. SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. ALL LUMBER NOT SPECIFICALLY NOTED TO BE D.F.#2 OR BETTER.ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR CMU SHALL BE PRESSURE TREATED UNLESS AN APPROVED BARRIER IS PROVIDED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY(OR ENGINEER APPROVED EQUAL)AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND ATTACHED PER MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS UNLESS NOTED OTIERWISE. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL FRAMING NAILS SHALL BE COMMON NAILS. NO BOX NAILS ALLOWED. FASTENERS AND ACCESSORIES IN CONTACT WITH PRESERVATIVE TREATED WOOD MUST BE HOT DIPPED GALVANIZED OR HAVE 7,MAX COATING. MECHANICAL: TIIE CONTRACTOR SIIALL COORDINATE SEISMIC RESTRAINTS OF ELECTRICAL EQUIPMENT,MECHANICAL,PLUMBING,FIRE SPRINKLER, MACHINERY,AND ASSOCIATED PIPING WITH THE STRUCTURE. ANY CONNECTIONS TO STRUCTURE NOT CONFORMING TO SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION(SMACNA),OR SPECIFICALLY DETAILED ON THE MECHANICAL ENGINEER'S DRAWINGS,SHALL BE DESIGNED IN ACCORDANCE OF THESE GENERAL NOTES,BY AN ENGINEER REGISTERED IN THE STATE OF OREGON,AND SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO FABRICATION. FLASHING AND WATERPROOFING: ALL FLASHING AND WATERPROOFING SHAT J.BE BY OTHERS UNLESS NOTED OTHERWISE ON THE PLANS. � A TM tiuPrEY 12078 SW GARDEN PL. - RTU Consulting Engineers By: JW Date: 10-1-15 7650 SW Bcvcland Street Chic By: Date: Suite 100 Tigard,Oregon 97223 Job II: 15260 Phone:(503)443-3900 Sheet: N1 �, Z , \E g �F off, „ed..% . ' 7• :4,44' `.' i u asw ., , ,,,. ,,,,,,,1 s, 4:',t ,‘, \ ..,„. .,4 p,4104,,. 4, * 4,,,,,,,,,,,, "0 0 I 1°•'''.,,,,''''\!* ., .,‘, ''':if,":'''`A '''' 'v ,,,, ,.., ,-, , : .z s .. ,ny •�i a"" Say ' r .. ''r I s (E)4x1 1 Pt RI INS �� e .w h 7,„it4‘,.4,',„,,' rq (E)GL'BEAMS @ . A,—;10,:''.*/"*". NEW RTU AND SEE E 1/SK2 r RB,S ,�C 11,1 fli!I SITE PLAN AMMON JW/z N' TM RIPPEY BY W DATE \]L/11- CONSULTING ENGINEERS 01K BY 12078 SW GARDEN.PL. - RTU DATE 7650 S.W. Beveland St,Suite 100 JOB NO 15260 _ Tigard, Oregon 97223 SHEET SKl OF Phone(503) 443-3900 NEW RTU(BY SUPLLIER) WEIGHT(INCLUDING CURB)=584 LBS. ALIGN CURB EDGES OVER EXISTING FRAMING AS SHOWN. FOR EXACT LOCATION SEE MECHANIAL PLANS. EXISTING 4x PURLINS @ 8'-0" O/C. EXISTING GLULAM BEAM EXISTING 2x > I TYP. SUB-PURLINS @ 2'-0"0/C. I l_'I NEW 4x8 HEADER UNDER SHORT EDGE OF UNIT CURB. NEW 4x8 HEADER UNDER UNIT HANG AT EACH END WITH CURB. HANG FROM EXISTING SIMPSON LUS48 HANGER. PURLINS WITH SIMPSON LUS48 CUT EXISTING SUB-PURLINS HANGER. AS NECESSARY AND HANG FROM NEW HEADER WITH SIMPSON LUS HANGER. NOTES: -INSTALL ALL FRAMING PRIOR TO INSTALLING CURB. -ALL WATERPROOFING IS BY OTHERS. -SEE MECHANICAL PLANS FOR ALL OTHER INFORMATION. cS1 FRAMING PLAN AT RTU K2 TM RIPPEY BY JW DATE ]YL CONSULTING ENGINEERS 12078 SW GARDEN PL. -RTU CHK BY DATE 7650 S.W.Beveland St,Suite 100 SOB NO 15260 Tigard,Oregon 97223 Phone(503)443-3900 _ SHEET SK2 OF • 3i t EQ. SPACED MECANICAL UNIT BOTH WAYS BY OTHERS TYP. Ir( 16 GA. CLIPS W/ (8) *10 TEK SCREWS PER 16 GA. CLIP CLIP, (4) CLIPS REQ'D. N.T.S. SEE PLAN VIEW FOR r A CLIP LOCATION 1 i 1 I 1'-0" TYP WOOD BLOCKING �j CLIP REQUIRED LOCATION (4) TOTAL FLASHING AND INSULATION MECH. UNIT NOT SHOWN FOR CLARITY OUTLINE WATERPROOFING BY OTHERS PLAN VIEW N.T.S. CENTER CURB ON PROVIDE "lm SCREWS a OR EXISTING STRUCTNEW URAL 1'-0" O/C AND AT 6" FROM MEMBER ENDS OF CURB. MINIMUM 11/2" EMBED INTO STRUCTURAL MEMBER, TYP. 0 a:07 /o\ AT CUBE RTU-01 SCALE: 11/2" = 1'-0" TM RIPPEY BYJW DATE CONSULTING ENGINEERS 12078 SW GARDEN PL. - RTU CHK BY DATE 7650 SW Beveland,Suite 100 Tigard,Oregon 97223 JOB NO 15260 Phone: (503)443-3900 SHEET SK3 OF Fax: (503)443-3700 NCll• UNGi (An'. 4'9° 99 x 7�l k33 T > (Ain w 1,4 I—I BLS Aur-cn)! ovr (E) pti2wz ►` (E)6 c Cm-, v$ PLARA.NNS '•a / � d`L Mz (it-))(E).7� lse, IL F,7 6a(3� LAS HT-8 r , �. LtA s h1ANG �L E�rrCV+ CAPAt d t`I RJR FIA-5 tANr-c- (I/ADAP . a Pv ""' MPi,rsL )(i f •)(a-o)7$' ' I6000 Ft-I6 tix 19 Pia 4 (58L'1/ )(s/) - 1$3� 3(- )14' M ILA s1,rNttm )6,4Ua {--4I1, - ,V).6) TA-UWISk- C 5 Al-0wrro 3 Ob e� pt, s + t"kGlt 5,360 ) � .4 14 CAIASE. C 16 C.,14*-Cfc f'v Asa Psi (J" /1))/4 !wr- OANCtrsrrnAs C-oPA--rr-DN c,t-R.,s `op F(AAJ s can/ (S-s `/it APPF2RAWCE • I` WAND CAPk•ct-' = 3ROo12. O1<- () CA, RFivM Gera-S E V SS DiAnl S� �Y FBI S EGf �N OK fP ,.lour TM RI PE l i i BY 3l4 DATE YY CONSULTING ENGINEERS 12078 SW GARDEN PL. - RTU CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB NO 15260 Tigard,Oregon 97223 Phone (503) 443-3900 SHEET C-1 of Design Maps Summary Report http://ehpl-eartlquale.cr.usgs.gov/designmaps/us/sunmary.php?tempi.. . :US Design Maps Summary Report User-Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 45.432°N, 122.763°W Site Soil Classification Site Class D -"Stiff Soil" Risk Category I/II/III _ ) ,:RA' x!:'...,11 Aa t R. s a ` r. n y 2n1 i i 8 averto[l , . £ x �� -2 3 f I I SOOOm �Z k s . 1 0ti t� f 17b :0 r ` k 4 £ j 3 2 i f Y +:, cx 1 4 x S €f x f S: ,. .s £ re : 1E x £t s £ ,Y t 4 1 •! x f., s @" ('-c7 6TB3t1f :Flf _ :i tof z: A { {( �y 1,1 �:su.. I t,� ei x .2 ,, it ii f € gWfYS -i 3 flwaukg.o : J s s s S !- c�lY•fsx:v 3 �s : i rxc` £s �.� 'x_ t s, 3 �r s, s s s f 5 f �i y+F - 4 sk 3 f ) T k ;OsW o ' zy x xf k s. : n:_. 2:9 - 3 t x �'` y . iv t.,f il}' s ` if :0:U�7: 0 s -�xpf # x: x f ii 4 IwR i -:kr � s `?, � sir n 4ity-: Y s�IerseF .� - AL•'c .:: s. // c Y! ff, �Q }. Efi kC.. £ t�. 4 f �`}y f:! �E'��!, i C` 4 ' ,�' � Xtt a f � ,f ' s ,' � � �� c FSA;, �>fy� {f`�.< k[L 1 ,�{�'� �i s f x x ^._ s ; 1 F asx �; •g�.✓ Frlf'. :. �4, 't ,s� z� f ��x x✓ f o t' "k r-r 1f Ft 3 �'� €: -2 i : ? z�f11� ue5t t ct I `ka, ,,,, si } xx dx ,' t;:pt lri3� U 8 a2d, f.TS7: 3 .,.., .:..>:... :Xs..xf. ., >::...,.. ... . r .. .E-• � .;. !� + .. ...... +�MaµfQuesc USGS-Provided Output Ss = 0.975 g SMS = 1.083 g Sus = 0.722 g Si = 0.423 g SMl = 0.667 g SD1 = 0.445 g For information on how the SS and S1 values above have been calculated from probabilistic(risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP"building code reference document. MCER Response Spectrum Design Response Spectrum 0.139 1.10 0.90 0.93 0.72 0.22 0.64 0.77 0.56 Tin 0.66 'a 0.48 0.55 f N 0.40 r Ln 0.44 0.32 0.33 • 0.24 0.22 0.16 0.11 0.02 0.00 0.00 0.00 0.20 0.40 0,66 0.20 1.00 1.20 1.40 1.60 1.20 2.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.20 2.00 Period,T(sec) Period,T(sec} Although this information Is a product of the U.S.Geological Survey,we provide no warranty,expressed or Implied,as to the accuracy of the data contained therein.This tool is not a substitute for technical subject matter knowledge. c,a Wind and Seismic Loads on Mechanical Unit Worksheet Calculates the wind and seismic forces for a rooftop mounted mechanical unit based on the ASCE 7-10. Hold down forces are calculated based on 0.6D + (0.6W or 0.7E) load cases. Wind and Seismic Loads on Mechanical Unit Windspeed:= 120mph Exposure:= "B" asd = no (Is wind speed ASD?) Seismic Parameters SDS:_ .722 ap •= 2.5 Rp•.= 6.0 IE:= 1.0 Building Dimensions Category:_ "II" Roof Elevation:= 16ft Building_Width:= 441ft Building Depth:= 118ft Mechanical Unit Dimensions Displacement:_ "Fan Unit" Weight:= 4901b UnitHeight:= 33in Width:= 44in Length:= 74in Curb:= 14in Curb_Width:= 37in (Dimension for Calculating Overturning Uplift) SUMMARY(ALL VALUES ARE ASD) Method Used= "ASCE 7-10-Section 29.5.1" D = 490 lb _ – WWindUpliftASD= 409 lb Displacement= "Fan Unit" (From ACSE 29.5-3) EASD= 124 lb = 2.542ft eismic �— WWindASD = 553 lb (From ACSE 29.5-2) \ 1 h 1.958 ft X= 3.083 ft Wmd TWindTotalASD= 408 lb Notes: TseismicASD= –45 lb 1.Positive sign convention shown. Negative values indicate opposite direction 2.X equals the width between attachment points for overturning fr\alk - preovtLE. O-ti's FAC44 ect-AlRR- tAt4T O (,Ux g �.�� ('s) U W s raft (4'1-ty-s (LIU2/c )/t.t Sue.g.'s 5th'/cSUJ i Fvf 01D x" lL�<<,A 14,4 01' /sckf,,,, c24. cAARJ3 to rreAr-q—/c, Assam n-10 S09.,,, p I'•0"06 I Via„ &kit ((tt p>)E R /scferAvJ 141 (I'-)(I'S,.)(135 33(-1" 582J GAS HEAT/ELECTRIC COOLING Bryan t SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS Heating&Cooling Systems Product Data JI'iGACYTM L I N E m tosim ma I !11 � C08515 (Shown with optional Louvered Hail Guard) ASHRAE Peron COMPLIANT MODEL NUMBER NOMENCLATURE • Position: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Example: 5 8 2 J E 0 6 A 0 7 2 A 0 B 0 AA Unit Type Packaging and Control 582-Gas Heat RTU,Legacy Series A= Standard Packaging,electro mechanical controls that require W7212 EconoMi$er IV Model B= LTL Packaging,electro mechanical J Puron®(R 410A)Refrigerant controls that require W7212 EconoMi$er IV C= Standard Packaging,electro mechanical controls that require W7220 EconoMi$er X Voltage F = LTL Packaging,electro mechanical E = 460-3-60 controls that require W7220 EconoMi$er X J = 208/230-1-60 P = 208/230-3-60 Factory Installed Options T = 575-3-60 OA =None NOTE:See the 582J 3 to 5 ton Price Pages Cooling Tons for a complete list of factory installed N 04- 3 tons options. co 05- 4 tons 06- 5 tons Outdoor Air Options A= None Refrig.System/Gas Heat Options B = Temperature Economizer,Barometric Relief, A= Standard One Stage cooling models/Nat.Gas Heat Standard Leak(W7212 or W7220) B = Standard One Stage cooling models/Low NOx Heat E = Temperature Economizer, Barometric Relief, C= Standard One Stage cooling models/SS HX Heat Standard Leak w/CO2(W7212 or W7220) G= One-Stage cooling models/Alum Heat Exchanger H= Enthalpy Economizer,Barometric Relief, with Perfect Humidity TM' Standard Leak(W7212 or W7220) H= One-Stage cooling models/Low NOx Heat L = Enthalpy Economizer,Barometric Relief, with Perfect Humidity Standard Leak w/CO2(W7212 or W7220) J = One-Stage cooling models/Stainless Steel Exchanger Q= Motorized 2 Position Damper with Perfect Humidity U= Temperature Economizer,Barometric Relief, Ultra Low Leak(W7220) Heat Level Input W= Enthalpy Economizer,Barometric Relief,Ultra Low Leak (W7220) Standard/Stainless Steel 072=72,000 115=115,000 Indoor Fan Options 150=150,000 0 = Direct Drive ECM Low NOx 2 = Medium Static Option 060=60,000 3 = High Static Option 090=90,000 120=120,000 Coil Options(RTPF)(Outdoor-Indoor-Hail Guard) A= Al/Cu-Al/Cu B = Precoat Al/Cu-Al/Cu Note:On single phase(-J)voltage code)models,the C= E-coat Al/Cu-Al/Cu following are not available as a factory installed option: D= E-coat Al/Cu-E-coat Al/Cu -Perfect Humidity E = Cu/Cu-Al/Cu -Coated Coils or Cu Fin Coils F = Cu/Cu-Cu/Cu -Louvered Hail Guards M= Al/Cu-Al/Cu—Louvered Hail Guard -Economizer or 2 Position Damper N= Precoat Al/Cu-Al/Cu—Louvered Hail Guard -Powered 115 Volt Convenience Outlet P= E-coat Al/Cu-Al/Cu—Louvered Hail Guard Q= E-coat Al/Cu-E-coat Al/Cu—Louvered Hail Guard R= Cu/Cu-Al/Cu—Louvered Hail Guard S= Cu/Cu-Cu/Cu—Louvered Hail Guard C14337 4 Table 2-AHRI COOLING RATING TABLE NET NOM. TOTAL • UNIT COOLING CAPACITY COOLING POWER SEER EER STAGES (TONS) CAPACITY ( ) (MBH) 582J*04 1 3 35.4 3.0 14.0 12.00 582J*05 1 4 47.5 4.0 14.0 12.00 582J*06 1 5 58.5 4.9 14.1 12.00 LEGEND NOTES: AHRI - Air Conditioning,Heating and Refrigeration 1. Rated in accordance with AHRI Standard 210/240. Institute Test Standard 2. Ratings are based on: ASHRAE - American Society of Heating,Refrigerating Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor and Air Conditioning,Inc. air temp and 95°F(35°C)db outdoor air temp. EER - Energy Efficiency Ratio 3. All 582J units comply with ASHRAE 90.1 Energy Standard for SEER - Seasonal Energy Efficiency Ratio minimum SEER and EER requirements. 4. 582J units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes. N C r�+.�J CERTIFIED. co in US Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the ASHRAE program For verification of certification for individual products,go to www.ahridirectory.org. COMPLIANT Table 3-HEATING RATING TABLE - NATURAL GAS& PROPANE AL/SS HEAT EXCHANGER THERMAL TEMP RISE AFUE UNITS GAS HEAT INPUT/OUTPUT INPUT/OUTPUT (DEG F) EFFICIENCY (%) STAGE 1 (MBH) STAGE 2(MBH) (%) LOW - 65/50 25- 55 82.0% 81.0% 04 MED - 90/73 45- 85 82.0% 81.5% m HIGH - - - - - t LOW - 65/50 20- 55 82.0% 81.0% a m 05 MED - 90/73 30- 65 82.0% 81.2% _c HIGH - 130/105 45- 80 82.0% 81.0% to LOW - 65/50 10- 55 82.0% 81.0% 06 MED - 90/73 25- 65 82.0% 81.2% HIGH - 130/105 35- 80 82.0% 81.0% LOW - 72/56 25- 55 82.0% N/A 04 MED 82/66 115/89 55- 85 80.0% N/A HIGH - - - - - a) . r LOW - 72/56 25- 55 82.0% N/A w 05 MED - 115/90 35- 65 81.0% N/A t HIGH 120/96 150/117 50-80 80.0% N/A ~ LOW - 72/56 20- 55 82.0% N/A 06 MED - 115/90 30-65 81.0%• N/A HIGH 120/96 150/117 40- 80 80.0% N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m). For information on propane or altitudes above 2000 ft (610 m),see the Application Data section of this book.Accessory Propane/High Attitude kits are also available. In the USA the input rating for altitudes above 2000 ft(610m)must be derated by 4%for each 1000 ft(305 m)above sea level.In Canada, the input rating must be derated by 10%for altitudes of 2000 ft(610 m)to 4500 ft(1372 m)above sea level. 8 Table 6—MINIMUM - MAXIMUM AIRFLOW RATINGS- NATURAL GAS & PROPANE HEAT COOLING AL HX HEATING SS HX HEATING VOLTAGE UNIT LEVEL • MINIMUM MAXIMUM MINIMUM MAXIMUM MINIMUM MAXIMUM LOW 900 1970 900 1970 582J*04 MED 900 1500 800 1520 800 1520 HIGH - - - - LOW 900 2470 900 2470 SINGLE 582J*05 MED 1200 2000 1050 2280 1050 2280 PHASE HIGH 1230 2190 1230 2190 LOW 900 3290 900 3290 582J*06 MED 1500 2500 1050 2730 1050 2730 HIGH 1230 2820 1230 2820 LOW 990 2190 990 2190 582J*04 MED 900 1500 1000 1550 1000 1550 HIGH - - - LOW 990 2190 990 2190 co THREE in PHASE 582J 05 MED 1200 2000 1330 2460 1330 2460 HIGH 1390 2220 1390 2220 LOW 990 2730 990 2730 582J*06 MED 1500 2500 1330 2880 1330 2880 HIGH 1390 2780 1390 2780 10 Table 7-PHYSICAL DATA (COOLING) 3 - 5 TONS _ 582J*04 582J*05 582J*08 I Refrigeration System . #Circuits/#Comp./Type 1/1 /Scroll 1/1/Scroll 1/1 /Scroll Puron®refrig.(R-410A)1 phase (lbs-oz) 7.1 10.5 16.0 Puron®refrig.(R-410A)3 phase (lbs-oz) 7.1 10.5 14.5 Perfect Humidity Puron®refrig.charge(lbs-oz) 10.4 15.3 26.0 Metering Device(A) Acutrol Acutrol Acutrol Perfect Humidity Metering Device(B) Acutrol+TXV Acutrol+TXV Acutrol+TXV ' High-press.Trip/Reset(psig) 630/505 630/505 630/505 Low-press.Trip/Reset(psig) 54/117 54/117 54/117 Compressor Capacity Staging(%) 100% 100% 100% Evap.Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 3/15 3/15 4/15 Total Face Area(ft2) 5.5 5.5 7.3 Condensate Drain Conn.Size 3/4-in 3/4-in 3/4-in Perfect Humidity Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 3.9 3.9 5.2 Evap.Fan and Motor Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct CO Max BHP 1 1 1 tf) Standard RPM Range 600-1200 600-1200 600-1200 Static Motor Frame Size 48 48 48 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1 /Centrifugal • Fan Diameter(in) 10 x 10 10 x 10 I 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.2 1.2 1.2 Medium RPM Range 560-854 560-854 770-1175 Static Motor Frame Size 48 48 48 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1 /Centrifugal Fan Diameter(in) 10x10 10x10 10x10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.5 1.5 1.5 High RPM Range 770-1175 770-1175 1035-1466 Static Motor Frame Size 56 56 56 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1 /Centrifugal Fan Diameter(in) 10x10 10x10 10x10 Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct Standard Max BHP 1 1 1 Static RPM Range 600-1200 600-1200 600-1200 3 phase Motor Frame Size 48 48 48 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 11 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.7 1.7 2.9 Medium RPM Range 770-1175 920-1303 1035-1466 Static Motor Frame Size 48 56 56 3 phase Fan Qty/Type 1 /Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 2.9 2.9 2.9 High RPM Range 1035-1466 1208-1639 1303-1687 Static 3 phase Motor Frame Size 56 56 56 Fan Qty/Type 1/Centrifugal 1 /Centrifugal 1 /Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Cond.Coil 1 phase Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 16.5 16.5 21.3 3 phase Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows..Fins/in. 1 /17 2/17 2/17 Total Face Area(ft2) 16.5 14.6 18.8 Cond.fan/motor Qty/Motor Drive Type 1/Direct 1/Direct 1/Direct Motor HP/RPM 1/8/825 1/4/1100 1/4/1100 Fan diameter(in) 22 22 22 Filters ! RA Filter#/Size(in) 2/16x25x2 2/16x25x2 4/16x25x2 I 2 OA inlet screen#/Size(in) 1/20 x 24 x 1 1/20 x 24 x 1 1/20 x 24 x 1 11 Table 9-PHYSICAL DATA (HEATING - THREE PHASE UNITS) 3 - 5 TONS . 582JE/P/T04 582JE/P/T05 582JE/P/T06 Electrical Three Phase Three Phase Three Phase Gas Connection #of Gas Valves 1 1 1 Nat.gas supply line press(in.w.g.)/(PSIG) 4—13/0.18—0.47 4—13/0.18—0.47 4—13/0.18—0.47 LP supply line press(in.w.g.)/(PSIG) 11 —13/0.40—0.47 11 —13/0.40—0.47 11 —13/0.40—0.47 Heat Anticipator setting(Amps) 1st stage 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 Natural Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 —3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT QO MED Rollout switch opens/closes 195/115 195/115 195/115 in Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Liquid Propane Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Low NOx Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 20—50 20—50 15—50 #of stages/#of burners(total) 1/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 30—60 30—60 25—60 #of stages/#of burners(total) — 1/3 1/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 40—70 35—70 — Not applicable 13 • 582J ' NOTES, C UNITED P.D.DON ANDO THIS DOCUMENT IS THE PROPER,'Of CARRIER CORPORATION SUBMISSION OF THESE DRAWINGS OR DOCUMENTS iECNNOLOG IE$STRACUS[,Y1 NO IS DELIY(1(0 UPON THE WREST 00101/101 THAT THE DOES NOT CONSTITUTE PART PERFORMANCE OR 1. DIMENSIONS ARE IN INCHES, DIMENSIONS UNIT J N (1 PHASE) A (3 PHASE) CACHIER TD,,, 001/01/0 WILL 10T BE DISCLOSED 09 VS(5■)110*1 CARRIER A00107)NC[Of CONTRACT. IN [ I ARE IN MILLIMETERS. 33 3/8- 14 7/8 14 718 CORPORATION'S 11111[Y CONSENT. 2. CENTER OF GRAVITY 582J 04 B 18471 [3771 13771 - CONNECTION SIZES 582J 05 3[384W 74 7/8 ,8 5/8 3. DIRECTION OF AIR FLOW • [8471 [3111 - 14721 A / 3/8' (351 DIA FIELD POWER SUPPLY HOLE 582J 06 11 3/8 14 718 18 5/8 B 2' 1501 DIA POWER SUPPLY KNOCKOUT [10511 [3771 14721 C 1 3/1. 1511 DIA GAUGE ACCESS PLUG D 7/8' 122] DIA FIELD CONTROL WIRING HOLE 33.3/8 1848] E 3)4••14 NPT CONDENSATE DRAIN F 1/2'-14 NPT GAS CONNECTION • 1 ' G 2 1/2' [641 DIA POWER SUPPLY KNOCKOUT• 32.1)4 - 1 ECONOMIZER HOOD 18181 (OPTIONAL) 16 14061 FILTER ACCESS PANEL THRU.THE-BASE CHART (TOOL-LESS) COMP I ♦ THESE HOLES AEOUIRED FOR USE • • ACCESS COEDENSER •PANEL COIL �.� •• ___ �3 CRB iMPWR001A01, 003A01 THREADED WIRE RCO'D HOLE M•rI ell INDOOR COIL '1.iii -� I CONDUIT SIZE USE SIZES (MAX.) ��Y..1.�Y1� ACCESS PANEL I N 1/2' ACC. 178' [22.21 W 00 i 25.5/8 10•7/8 ♦ 0 1/2' 248 1/8' 122.21 •�, I /� [6521 12771 RETURN Y • 1/4' 1001,0011 POWER) 1/8' [28.1] 1 II \®�� RETURN AIR AIR 2.. (0031 1/2' FPT GAS 1 3/16' 130.01 44 p d [11171 J (((��� 2-518-1£ \�\--���� I 1 I FITTINGS UFOR EONLY E 0.7, 1AZTARE PROVIDED FOR MBACK [iYP1 ' \ E ALT. I SELECT EITHER 3/4'OR 1/2' CURB /'■ • CONDENSATE 17-3/4 ' FOR POWER. DEPENDING ON WIRE SIZE WIDTH I "K DRAIN OPENING [4511 1001) PROVIDES 3/1' FPi iHRU CURB �1)- O --1 IN BASE PAN SUPPLY . 26-1/2 1741j8 SUPPLY •� FLANGE d FITTING. 1►iT1y 18-118 , I - AIR 16731 11591 AIR 16-1/8 14'1// 12-1/4 _ 1 "—L-• < N CA I f11+11 136131 13111 SEE THRU • :'7M •� Cl) 1 1 [,571 . y A o ,_ 4 3-3/8 A 12-1/8 ---- 1851 ( 25 FLUE [307] IT (6361 41001 HOOD — 18-1/2 — �1 in' K TOP 14701 0,/2 �1.�Fy M — — [118] 12651 1-1/4 \'� [1161 f [321 (-" ELECTRICAL Kno O � _= DISCONNECT �I • •'7 I LOCATION ••• ���_1 I• N CONDENSER —— �I CONTROL BOK INDOOR BLOWER E STD FILTER )1 COIL B. ACCESS PANEL ACCESS CONDENSATE • O y I == J - -- [63818 LiriTh-11../._ OUTSIDE Z OPTIONAL ki!1= I 1 16-3/4 RETURN AIR IINSTALLED - , 19112 OFACIORI �F 1 .,.„,,-HANDLE [28918 I SUPPLY(AIA I AIR CONVENIENCE I 1491] INSTALLED I OUTLET 1 DISCONNECT _ 1 __ Q ; (53911•L __—__ 11 6 5/8 1 ��.�!Er e..( .� 11681 `c c II �. (](]g 1,5581 3-3/4 ' HANDLE L 8-3/8 6-5/8 L 7 6 4 1951 46-3/4 - 30-1/8 1213) [1691 [1771 11521 111871 [1641 713/8 26-7/8 16821 BAROMETRIC 118881 31-1/4 RELIEF [7931 FLOW LEFT AIRPIY I'RETURN FRONT AIR RIGHT 305(1 DATE SUPEKEDES 582J 04-06 SINGLE ZONE ELECTRICAL REM ,OF2 08-14-14 - COOLING WITH GAS HEAT 48KC000284 9 A N V 0 UNITED P.O.IOU OOP THIS DOCUMENT IS THE PROPERTY Of CARRIER COHPOUHTI N SUNNISSIOR 0,THESE DRAWINGS 011 DOCUMENTS TECHNOLOGIES SYRACUSE.NT ARE IS DELIVERED UPON TH[[RPRESS CORD111011 1x01 IHE DOES NOT CONSTITUTE PART PERFORMANCE OR STD. UNIT CORNER CORNER CORNER CORNER C G HEIGHT CARRIER IJMH1 CORPORAS OILS NOT B[D CONSENT.OR USFO NITxOUi CARRI[1 ACCEPTANCE Or CONTRACT. UNIT WEIGHT WEIGHT lA) WEIGHT CBI WEIGHT ICI WEIGHT (D1 CORPORATION'S WRITTEN CONSENT. LBS. NG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. 4 T Z 5822 04 490 222 120 54 111 50 125 56 135 61 35 3/4 19081 24 3/4 16281 18 7/8 1459I 582J 05 544 246 130 58 126 51 142 64 146 66 36 3/4 19331 24 3/4 16281 18 7/8 14191 5822 06 597 270 141 64 156 70 158 71 142 64 39 1/8 19931 23 1/2 15911 20 1/8 15111 •STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B 1 11;11%72=49.4 el llll(������riir T I .rill'- :.,,.. .)./-----2.'1 . CA N �. ril [ _ t■1 CS a S cil O con CORNER D , CORNER C co Ro o [ CA I TOP 1~y Os col ril N I. H 0 1 CA Z W9 .. ft 7__ Ili • Z FRONT SHEET DATE SUPEACEDES 582J 04-06 SINGLE ZONE ELECTRICAL HEY 20F2 08-14-14 - COOLING WITH GAS HEAT 486C000284 - 2 A N V . 582J . ROOF CURB A NOTES'. CONNECTOR PKG.ACC. GAS CONNECTION TYPE GAS FITTING POWER WIRING CONTROL WIRING ACCESSORY CONVENIENCE ACCESSORY# 1.ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. FITTING FITTING OUTLET WIRING CONNECTOR 2.INSULATED PANELS:25.4[11 THK.POLYURETHANE FOAM,44.5[1-3/4]#DENSITY. CRRFCURB001A01 14 3.DIMENSIONS IN(]ARE IN MILLIMETERS. CRBTMPWR001A01 THRU THE CURB 3/4'[19]NPT 1356] 4.ROOFCURB:18 GAGE STEEL. - 5.ATTACH DUCTWORK TO CURB.(FLANGES OF DUCT REST ON CURB). - - 3/4"119]NPT 12"112.7]NPT 1/2"[12.7)NPT CRRFCURB002A01 I8 01 6.SERVICE CLEARANCE 4 FEET ON EACH SIDE. CRBTMPWR003A01 THRU THE BOTTOM 1/2"[12.7]NPT 7.172ZI, DIRECTION OF AIR FLOW. 8.CONNECTOR PACKAGE CRBTMPWR001A01 IS FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWR003A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. 1-3/4" II 11.3/4 1.00' 11 3/41298.5]WIDE [137 5A2' 1.71 (3038] 125.1] INSULATED DECK PANELS, 1 LL _ 1 252' [ss2.z.z] (/1 8 5/161217.5]WIDE I ' INSULATED DECK PANEL 1 I r 1 N 1.7/4' • uQ• J ` / ` [4#41 I 1'4-13/16' SEE NOTE#2 til A 4 96' ii SECTION E-E GAS SERVICE PLATE [427]INSIDE I1 1 [126.0] 70.87' SCALE 0.250 THRU THE CURB I 216-311/6" [1800.2] DRILL HOLE QS I ,` OZ I 2"150.8]® I 1 0 - ASSEMBLY(IF �� REQUIRED) I 40.0.0/ (SEE NOTE#e) ./ RETURN AIR 110: OPENING .1 15.19" 701/3/4'[44.5] �y, Cr [386.8] E E �" RID [554.7] A - 1 32.19" lens] VIEW"B" L■1 �j CORNER DETAIL I� 1 14.00' SUPPLY AIR 16.03' / RETURN AI` •��4 1-3/4" I4 VI [35516] I OPENING ) 140721 / \' [44.41• CO tnil 1.7/4" , N �[ .� rzr� 1 1 V A A1.75' J 20.41' -3.00' GASKE NIT "A" ICI 1 [44.5] (518.3] 176.21 (SUPPLIED WITH CURB) O -.0 -13.78" 1350.0] j- -- 'll(FIELD SUPPLIED) II 5'7J/B' (103351 TYPICAL(4)SIDES [1711.3] Z (FIELD SUPPLIED) 7/16' CA 111 OECD ER FLASHING 3,1[9446] � `�/ A _ t 1 OOFING FELT SEE VIEW"B" (FIELD SUPPLIED) CERTIFIED DRAWING T STRIP IT1.o1 in (FIELD SUPPLIED) ,....„ 49116' DRAWN°RELEASE LEVEL.. PRODUCTION - -OOFING MATERIAL 1115.51 © \1` (FIELD SUPPLIED (///�}}}�}.4./_1 UNLESS OTHERWISE SPECIFIED ' \ �/` PRIOJECTION TAP J T` 1 DIMENSIONS TOLERANCES O INCHES DOCUMENT MD INF XPORINTION CONNIVED MORES I I 1 \\ ��ERMO \\IVII 10EL ]DEC ]OEL ANG RuT WRITNDUTIDR4Ano"Of COMA CawduTON. MATERIAL - - - t_ UNCOSEDTO TNEES S HOLE OR NPOR ` AUTHORIZATION NUMBER TIREC� SUPPLY AIR RETURN AIR \ / •IGID INSULATION - 1041738 CURB ASY,ROOF //�//////W/// / ‘‘i/I. (FIELD SUPPLIED) - ENGINEERING MANUFACTURING (004-007) s": ENGINEERING REOUIREMENIS - -- - SIZE DRAWING NUMBER REV \\, OVERALL DIM.5'-7 3/8'WAS 5'-7 7/8;18GA T-005,V-002 DRAFTER CHECKER D 48TC400427 B - A MATERIAL WA 16 GA.;NAIL FIELD SUPPLIED WAS 04/22/13 MMC - 1067898 WEIGHT - MMC 06/17/11- SLEET 5 O 5 WITH CURB SURFACE FINISH MFGIPURCH MODEL (INTERNAL USE ONLY) NEXT DRAWING SCALE OSTHIBUTION REV REVISION RECORD DATE ST CHICO APPD ECN NO. - PURCH - N/A MMC 0 8 0 582J N 1J1 r e Architectural & Engineering Specifications December 2007 DESCRIPTION QTRN Series BLOWER: • Plug-in, permanently lubricated motor-engineered for continuous operation Fans • Dynamically balanced centrifugal blower wheel for quiet, efficient on quiet performance MODELS QTRN050F QTRN080 QTRN110 • Low RPM for quiet operation , � • Resilient anti-vibration motor mounts HOUSING: • Rugged,26 gauge, galvanized steel construction • Polymeric,4"round duct connector with tapered sleeve and no metallic clatter • 7-5/8"height allows for 2"x 8"(nominal)joist installations ,111 • Sturdy,easy,four-point mounting directly to joist • Includes unique spacer(patent pending)for mounting to engineered"I"joists • Can be mounted in ceilings up to 12/12 pitch GRILLE: • Innovative design-tthn • Innovative design-the result of extensive research with designers and consumers BUILDER PACKS: • Model QTRNO5OF includes blower and grille only(packed 1 per carton) • Rough-in housing required-order NuTone Model QTXRN000HF(4 housings per carton) - Includes hanger bars to position housing anywhere ARCHITECT'S SPECIFICATION between 16"to 24"-on-center joists(4 sets of hangers per • Ceiling Ventilator shall be NuTone Model QTRNO5OF(QTRN080) carton) (QTRN110). - Two sets of mounting holes for hanger bars allow flush installation with bottom or top of drywall • Ceiling Ventilator shall have corrosion resistant galvanized steel CONTROLS (Purchase separately): housing with four-point mounting capability. It shall be ducted to • Refer to NuTone's catalog for a complete line of accessories a roof or wall cap using 4"round ductwork. to effectively adapt these fans to your construction • Blower assembly shall be removable, have a centrifugal-type requirements. blower wheel and a permanently lubricated motor designed for U.L. Listed for use over bathtubs and showers when connected continuous operation and mounted with resilient anti-vibration to a GFCI protected branch circuit(ceiling mount only). mounts. 3-Year Warranty ® • Non-metallic damper/duct connector shall be included. 2100 •� • Air delivery shall be no less than 50(80) (110) CFM and sound NV' level no greater than 0.4 (1.0) (1.5) Sones. All air and sound CERTIFIED ratings shall be certified by HVI. • Ceiling Ventilator shall be U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit. INSTALLATION Complete installation instructions are included with each Fan. Broan-NuTone LLC Hartford,Wisconsin www.nutone.com 888-336-3948 REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 70M 99044088A PERFORMANCE RATINGS QTRN SERIES FANS . HVI PERFORMANCE AIR FLOW PERFORMANCE Sones CFM Model @0.1"Ps @0.1"Ps MODEL QTRNO5OF QTRNO5OF 0.4 50 0.6 QTRN080 1.0 80 QTRN110 1.5 110 o.s • 0.4 ® Cii HVI-2100 CERTIFIED RATINGS comply with 2100 II, new testing technologies and procedures HVI prescribed by the Home Ventilating Institute,for v 0.3 off-the-shelf products,as they are available to consumers.Product performance is rated at 0.1 d 0.2 CERTIFIED in.static pressure,based on tests conducted in AMCA's state-of-the-art test laboratory.Sones area a measure of aboratory measurements.ements.loudness, 0.1 \ based on laboratory measurements. 0.0 0 10 20 30 40 50 60 70 Airflow(cfm) AMPS WEIGHT Model Amps Model Shipping MODEL QTRN080 QTRNO5OF 0.3 Weight 0.9 QTRN080 0.7 QTRNO5OF 5.9 lbs. 0.8 `_ QTRN110 0.9 QTRN080 10.6 lbs. 0.7 �� QTRN110 10.6 lbs. rn 0.6 0.5 (111111) 0.4 d 0.3 0.2 0.1 ` 018 �O.O O 10 20 30 40 s0 60 70 80 90 100 Airflow(cfm) -4 0-i-,-- o MODEL QTRN110 0.7 �� yny 0.6 IOI I � 0.4 ' h 0.3 0. 0.2 . \ 01 0.0 0 10 20 30 40 50 60 70 80 90 100 110 120 Airflow (cfm) NI. 13 IA. NuTo n e Broan-NuTone LLC Hartford,Wisconsin www.nutone.com 888-336-3948