Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
F(s),ot S-• 000S3 7315 Sw /c 4,/� 14795 S.W. 72nd Avenue PORTLAND, OR 97224 PHONE 503-620-4020 FIRE, INC. CCB# 64 670-1 058 Hydraulic Calculations FIRE PROTECTION CONTRACTORS DELT,L\., 1 ERE PROTECTION CONTRACTORS 14795 9,72nd, FORTL),I R 97224 (501}620-4fl20 DeltaFire, Inc 14795 Sw 72nd Ave Portland, OR 97224 503-620-4020 Job Name : 155400-QCD-FRZR-HIGHPILE-4 Building : SP1 Location : 7319 SW KABLE LANE, SUITE 500, TIGARD OR System : 1 Contract : 15-5400 Data File : 155400-QCD-FRZR-HIGHPILE-4 Area 1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C DeltaFire, Inc Page 1 155400-()CD-FRZR-HIGHPILE-4 Date City Water Supply: Demand: C1 - Static Pressure : 104 D1 - Elevation : 10.251 C2 - Residual Pressure: 92 D2- System Flow : 1109.15 C2- Residual Flow : 2599 D2- System Pressure : 84.422 Hose( Demand ) : 500 D3- System Demand : 1609.15 Safety Margin : 14.634 150 ■ 140 130 P 120 R 110 : Gf Q _ E 100 — -� - C2 C S 90 D 0 S 80 . D3 U 70 R 60 E 50 40 30 20 10 7 D1 300 600 900 1200 1500 1800 2100 2400 2700 FLOW NA1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary DeltaFire, Inc Page 2 155400-QCD-FRZR-HIGHPILE-4 Date Fitting Legend Abbrev. Name '/ ' 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 • Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a*show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a *will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD DeltaFire, Inc Page 3 155400-QCD-FRZR-HIGHPILE-4 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 23.67 11.2 14.06 na 42.0 0.42 100 7.0 2 26.0 22.53 na 3 26.0 22.55 na 4 26,0 23.45 na 5 26.0 25.37 na 6 26.0 36.64 na 7 24.12 41.24 na 8 24.12 41.4 na 9 24.12 41.89 na 10 24.12 42.25 na 11 26.0 41.74 na 12 26.0 46.62 na 13 24.12 47.74 na 14 24.12 48.09 na 15 24.12 48.59 na 16 24.12 49.37 na 17 24.12 50.67 na 18 24.12 52.43 na 19 24.12 54.56 na 20 24.12 57.11 na 21 24.12 72.15 na RSR 0.0 84.01 na HOSE 0.0 84.28 na 500.0 TEST 0.0 84.42 na 22 23.67 11.2 14.43 na 42.54 0.42 100 7.0 23 26.0 23.13 na .. 24 26.0 46.04 na 25 23.67 11.2 15.6 na 44.23 0.42 100 7.0 26 26.0 22.5 na 27 23.67 11.2 15.63 na 44.28 0.42 100 7.0 28 23.67 11.2 15.65 na 44.3 0.42 100 7.0 29 26.0 22.57 na 30 26.0 23.07 na 31 23.67 11.2 15.98 na 44.78 0.42 100 7.0 - 32 23.67 11.2 16.25 na 45.14 0.42 100 7.0 33 23.67 11.2 17.56 na 46.93 0.42 100 7.0 34 23.67 11.2 16.51 na 45.51 0.42 100 7.0 35 26.0 25.89 na 36 26.0 26.14 na 37 26.0 26.19 na 38 26.0 47.71 na 39 23.67 11.2 16.6 na 45.63 0.42 100 7.0 40 26.0 26.04 na 41 26.0 26.07 na 42 26.0 27.53 na 43 26.0 37.22 na 44 24.12 41.24 na 45 24.12 41.31 na 46 24.12 41.4 na 47 26.0 41.31 na 48 26.0 53.02 na 49 23.67 11.2 16.69 na 45.76 0.42 100 7.0 50 23.67 11.2 17.48 na 46.83 0.42 100 7.0 51 26.0 25.89 na 52 23.67 11,2 17.55 na 46.91 0.42 100 7.0 53 23.67 11.2 17.6 na 46.99 0.42 100 7.0 54 23.67 11.2 17.65 na 47.05 0.42 100 7.0 55 26.0 11.2 22.11 na 52.66 0.42 100 7.0 56 26.0 26.17 na 57 26.0 26.29 na 58 26.0 27.03 na 59 26.0 45.74 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard DeltaFire, Inc Page 4 155400-QCD-FRZR-HIGHPILE-4 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 60 26.0 11.2 22.14 na 52.7 0.42 100 7.0 61 26.0 26.2 na 62 26.0 26.64 na 63 26.0 28.0 na .64 26.0 37.41 na 65 26.0 11.2 22.21 na 52.79 0.42 100 7.0 66 26.0 11.2 22.52 na 53.14 0.42 100 7.0 67 26.0 11.2 22.85 na 53.53 0.42 100 7.0 68 26.0 11.2 23.67 na 54.5 0.42 100 7.0 69 23.67 11.2 24.41 na 55.34 0.42 100 7.0 70 26.0 40.29 na 71 26.0 40.67 na 72 26.0 50.69 na 73 23.67 11.2 24.64 na 55.6 0.42 100 7.0 74 26.0 40.44 na 75 24.12 41.43 na 76 26.0 41.48 na 77 26.0 55.43 na 78 26.0 41.42 na 79 26.0 46.94 na 80 24.12 42.52 na 81 26.0 41.98 na 82 26.0 46.38 na 83 24.12 47.47 na 84 24.12 42.71 na 85 26.0 42.15 na 86 26.0 46.21 na 87 24.12 47.27 na 88 24.12 42.85 na 89 26.0 42.27 na . 90 26.0 0 46.09 na 91 24.12 47.14 na 92 24.12 43.02 na 93 26.0 42,43 na • 94 26.0 45.93 na 95 24.12 46.96 na 96 24.12 43.08 na 97 26.0 42.47 na 98 26.0 45.89 na 99 24.12 46.91 na 100 24.12 43.1 na 101 26.0 42.49 na 102 26.0 45.86 na 103 24.12 46.89 na 104 24.12 43.11 na 105 26.0 42.5 na 106 26.0 45.86 na 107 24.12 46.88 na The maximum velocity is 24.97 and it occurs in the pipe between nodes 20 and 21 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 5 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 42.00 1.049 2E 4.0 9.460 14.062 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 2 42.0 0.5134 0.0 18.460 9.478 Vel= 15.59 2 18.43 2.067 0.0 0.500 22.531 to 120.0 0.0 0.0 0.0 3 60.43 0.0380 0.0 0.500 0.019 _ _Vel = 5.78 3 44.28 2.067 0.0 8.830 22.550 to 120.0 0.0 0.0 0.0 4 104.71 0.1023 0.0 8.830 0.903 Vel= 10.01 4 45.15 2.067 0.0 9.670 23.453 to 120.0 0.0 0.0 0.0 5 149.86 0.1987 0.0 9.670 1.921 Vel= 14.33 -- 5 46.93 2.067 T 10.0 24.270 25.374 to 120.0 0.0 10.000 0.0 6 196.79 0.3287 0.0 34.270 11.265 Vel= 18.82 _ 6 0.0 2.157 T 12.307 1.880 36.639 to 120.0 0.0 12.307 0.814 7 196.79 0.2671 0.0 14.187 3.790 Vel= 17.28 7 30.25 4.26 0.0 12.080 41.243 to 120.0 0.0 0.0 0.0 8 - 227.04 0.0127 0.0 12.080 0.153 Vel= 5.11 8 178.62 4.26 0.0 13.420 41.396 to 120.0 0.0 0.0 0.0 9 405.66 0.0370 0.0 13.420 0.497 Vel= 9.13 9 -53.57 4.26 0.0 12.500 41.893 to 120.0 0.0 0.0 0.0 10 352.09 0.0285 0.0 12.500 0.356 Vel= 7.93 10 -301.94 2.157 T 12.307 1.880 42.249 to 120.0 0.0 12.307 -0.814 11 50.15 0.0213 0.0 14.187 0.302 _ Vel= 4.40 11 0.0 2.067 2T 20.0 166.370 41.737 to 120.0 0.0 20.000 0.0 12 50.15 0.0262 0.0 186.370 4.884 Vel= 4.79 12 0.0 2.157 T 12.307 1.880 46.621 to 120.0 0.0 12.307 0.814 13 50.15 0.0214 0.0 14.187 0.303 Vet= 4.40 13 301.94 4.26 0.0 12.500 47.738 to 120.0 0.0 0.0 0.0 14 352.09 0.0285 0.0 12.500 0.356 Vel= 7.93 14 53.57 4.26 0.0 13.420 48.094 to 120.0 0.0 0.0 0.0 15 405.66 0.0370 0.0 13.420 0.497 Vel= 9.13 15 140.70 4.26 0.0 12.080 48.591 to 120.0 0.0 0.0 0.0 16 546.36 0.0642 0.0 12.080 0.776 Vel= 12.30 16 157.43 4.26 0.0 12.750 49.367 to 120.0 0.0 0.0 0.0 17 703.79 0.1026 0.0 12.750 1.308 Vel= 15.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 6 1 55400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes • Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 17 144.78 4.26 0.0 12.080 50.675 to 120.0 0.0 0.0 0.0 18 848.57 0.1450 0.0 12.080 1.752 Vel= 19.10 18 91.66 4.26 0.0 12.170 52.427 to 120.0 0.0 0.0 0.0 19 940.23 0.1753 0.0 12.170 2.134 Vel= 21.16 19 80.46 4.26 0.0 12.500 54.561 to 120.0 0.0 0.0 0.0 20 1020.69 0.2041 0.0 12.500 2.551 Vel= 22.98 20 88.46 4.26 E 13.167 50.000 57.112 to 120.0 0.0 13.167 0.0 21 1109.15 0.2381 0.0 63.167 15.037 Vel= 24.97 21 0.0 6.357 E 17.603 24.120 72.149 to 120.0 0.0 17.603 10.446 RSR 1109.15 0.0339 0.0 41.723 1.414 Vel= 11.21 RSR 0.0 8.27 E 28.468 10.000 84.009 to 140.0 0.0 28.468 0.0 HOSE 1109.15 0.0071 0.0 38.468 0.273 Vet= 6.62 HOSE 500.00 8.27 0.0 10.000 84.282 Qa=500 to 140.0 0.0 0.0 0.0 TEST 1609.15 0.0140 0.0 10.000 0.140 Vel= 9.61 0.0 1609.15 _ 84.422 K Factor= 175.13 22 42.54 1.049 2E 4.0 9.460 14.429 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 23 42.54 0.5258 0.0 18.460 9.706 Vel= 15.79 _ 23 114.88 2.067 T 10.0 95.360 23.126 to 120.0 0.0 10.000 0.0 24 157.42 0.2175 0.0 105.360 22.919 Vel= 15.05 24 0.0 2.157 T 12.307 1.880 46.045 to 120.0 0.0 12.307 0.814 16 157.42 0.1768 0.0 14.187 2.508 Vel= 13.82 0.0 157.42 49.367 K Factor= 22.40 25 44.23 1.049 2E 4.0 5.000 15.597 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 26 44.23 0.5651 0.0 14.000 7.911 Vel= 16.42 26 -25.80 2.067 0.0 7.830 22.499 to 120.0 0.0 0.0 0.0 2 18.43 0.0041 0.0 7.830 0.032 Vel= 1.76 0.0 18.43 22.531 K Factor= 3.88 27 44.28 1.049 2E 4.0 5.000 15.632 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 3 44.28 0.5662 0.0 14.000 7.927 Vel= 16.44 0.0 �. 44.28 22.550 K Factor= 9.32 • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 7 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 28 44.30 1.049 2E 4.0 5.000 15.646 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 29 44.3 0.5666 0.0 14.000 7.933 Vel = 16.45 29 25.80 2.067 0.0 10.170 22.570 to 120.0 0.0 0.0 0.0 30 70.1 0.0487 0.0 10.170 0.495 Vel = 6.70 30 44.78 2.067 0.0 0.500 23.065 to 120.0 0.0 0.0 0.0 23 114.88 0.1220 0.0 0.500 0.061 Vel= 10.98 0.0 114.88 23.126 _ K Factor= 23.89 _ 31 44.78 1.049 2E 4.0 5.000 15.983 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 30 44.78 0.5779 0.0 14.000 8.091 Vel= 16.62 • 0.0 44.78 23.065 K Factor= 9.32 32 45.14 1.049 2E 4.0 5.000 16.247 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 4 45.14 0.5868 0.0 14.000 8.215 Vel= 16.76 0.0 45.14 23.453 K Factor= 9.32 33 46.93 1.049 2E 4.0 5.000 17.557 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 5 46.93 0.6304 0.0 14.000 8.826 Vel= 17.42 0.0 46.93 25.374 K Factor= 9.32 26 25.80 2.067 0.0 9.250 22.499 to 120.0 0.0 0.0 0.0 29 25.8 0.0077 0.0 9.250 0.071 Vel= 2.47 0.0 25.80 22.570 K Factor= 5.43 34 45.51 1.049 2E 4.0 8.450 16.510 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 35 45.51 0.5956 0.0 17.450 10.394 Vel= 16.89 35 6.46 2.067 0.0 8.750 25.895 to 120.0 0.0 0.0 0.0 36 51.97 0.0280 0.0 8.750 0.245 Vel= 4.97 36 47.05 2.067 0.0 0.500 26.140 to 120.0 0.0 0.0 0.0 37 99.02 0.0920 0.0 0.500 0.046 Vel= 9.47 37 45.76 2.067 T 10.0 105.530 26.186 to 120.0 0.0 10.000 0.0 38 144.78 0.1863 0.0 115.530 21.527 Vel= 13.84 38 0.0 2.157 T 12.307 1.880 47.713 to 120.0 0.0 12.307 0.814 17 144.78 0.1514 0.0 14.187 2.148 Vel= 12.71 0.0 144.78 50.675 K Factor= 20.34 Computer Programs by Hydrated Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 8 155400-QCD-FRZR-HIG H PI LE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes """' Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 39 45.63 1.049 2E 4.0 8.450 16.600 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 40 45.63 0.5986 0.0 17.450 10.445 Vel= 16.94 40 40.36 2.067 0.0 0.500 26.036 to 120.0 0.0 0.0 0.0 41 85.99 0.0700 0.0 0.500 0.035 Vet= 8.22 41 46.99 2.067 0.0 9.170 26.071 to 120.0 0.0 0.0 0.0 42 132.98 0.1592 0.0 9.170 1.460 Vel= 12.71 42 46.92 2.067 T 10.0 24.780 27.531 to 120.0 0.0 10.000 0.0 43 179.9 0.2784 0.0 34.780 9.684 Vel = 17.20 43 0.0 2.157 T 12.307 1.880 37.215 to 120.0 0.0 12.307 0.814 44 179.9 0.2263 0.0 14.187 3.210 Vel= 15.80 44 -30.26 4.26 0.0 12.080 41.239 to 120.0 0.0 0.0 0.0 . 45 149.64 0.0059 0.0 12.080 0.071 Vel= 3.37 45 19.28 4.26 0.0 12.170 41.310 to 120.0 0.0 0.0 0.0 46 168.92 0.0073 0.0 12.170 0.089 Vel= 3.80 46_ v~ -88.46 2.157 T 12.307 1.880 41.399 to 120.0 0.0 12.307 -0.814 47 80.46 0.0510 0.0 14.187 0.724 Vel= 7.06 47 0.0 2.067 2T 20.0 166.380 41.309 to 120.0 0.0 20.000 0.0 48 80.46 0.0628 0.0 186.380 11.713 Vel= 7.69 48 0.0 2.157 T 12.307 1.880 53.022 to 120.0 0.0 12.307 0.814 19 80.46 0.0511 0.0 14.187 0.725 Vel= 7.06 0.0 80.46 54.561 _ K Factor= 10.89 49 45.76 1.049 2E 4.0 8.450 16.694 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 37 45.76 0.6018 0.0 17.450 10.501 Vel= 16.99 0.0 45.76 26.186 K Factor= 8.94 50 46.83 1.049 2E 4.0 6.000 17.480 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 51 46.83 0.6279 0.0 15.000 9.419 Vel= 17.38 51 -6.47 2.067 0.0 8.330 25.890 to 120.0 0.0 0.0 0.0 40 40.36 0.0175 0.0 8.330 0.146 Vel= 3.86 0.0 40.36 _ 26.036 K Factor= 7.91 52 46.91 1.049 2E 4.0 8.450 17.546 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 42 46.91 0.6300 0.0 17.450 10.994 Vel= 17.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 9 155400-QCD-FRZR-HIGH PI LE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 46.91 27.531 K Factor= 8.94 53 46.99 1.049 2E 4.0 6.000 17.601 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 41 46.99 0.6319 0.0 15.000 9.479 Vel= 17.44 0.0 46.99 26.071 K Factor= 9.20 54 47.05 1.049 2E 4.0 6.000 17.647 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 36 47.05 0.6335 0.0 15.000 9.502 Vel = 17.47 0.0 47.05 26.140 K Factor= 9.20 51 6.46 2.067 0.0 8.830 25.890 to 120.0 0.0 0.0 0.0 35 6.46 0.0006 0.0 8.830 0.005 Vel= 0.62 0.0 6.46 _ 25.895 K Factor= 1.27 55 52,66 1.049 T 5.0 0.200 22.110 K Factor= 11.20 to 120.0 0.0 5.000 0.0 56 52.66 0.7804 0.0 5.200 4.058 Vel= 19.55 _ 56 -18.28 2.067 0.0 9.250 26.168 to 120.0 0.0 0.0 0.0 57 34.38 0.0131 0.0 9.250 0.121 Vel= 3.29 . 57 52.79 2.067 0.0 10.170 26.289 to 120.0 0.0 0.0 0.0 58 87.17 0.0729 10.170 0.741 Vel = 8.33 58 53.54 2.067 T 10.0 95.860 27.030 to 120.0 0.0 10.000 0.0 59 140.71 0.1767 0.0 105.860 18.709 Vel= 13.45 59 0.0 2.157 T 12.307 1.880 45.739 to 120.0 0.0 12.307 0.814 15 140.71 0.1437 0.0 14.187 2.038 Vel= 12.35 0.0 140.71 48,591 K Factor= 20.19 60 52.70 1.049 T 5.0 0.200 22.139 K Factor= 11.20 to 120.0 0.0 5.000 0.0 61 52.7 0.7813 0.0 5.200 4.063 Vel= 19.56 61 18.28 2.067 0.0 8.830 26.202 to 120.0 0.0 0.0 0.0 62 70.98 0.0498 0.0 8.830 0.440 _ Vel= 6.7.9 62 53.14 2.067 0.0 9.670 26.642 to 120.0 0.0 0.0 0.0 63 124.12 0.1401 0.0 9.670 1.355 Vet= 11.87 63 54.50 2.067 T 10,0 24.270 27.997 to 120.0 0.0 10.000 0.0 64 178.62 0.2748 0.0 34.270 9.417 Vel = 17.08 - 64 0.0 2.157 T 12.307 1,880 37.414 to 120.0 0.0 12.307 0.814 8 178.62 0.2233 0.0 14.187 3.168 Vel= 15.68 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 10 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes """ • Point Qt Pf/Ft Eqv. Ln. Total Pf Pn • 0.0 178.62 41.396 K Factor= 27.76 65 52.79 1.049 T 5.0 0.200 22.213 K Factor= 11.20 to 120.0 0.0 5.000 0.0 57 52.79 0.7838 0.0 5.200 4.076 Vel= 19.60 0.0 52.79 26.289 K Factor= 10.30 66 53.14 1.049 T 5.0 0.200 22.515 K Factor= 11.20 to 120.0 0.0 5.000 0.0 62 53.14 0.7937 0.0 5.200 4.127 Vel = 19.73 0.0 53.14 26.642 K Factor= 10.30 67 53.53 1.049 T 5.0 0.200 22.847 K Factor= 11.20 to 120.0 0.0 5.000 0.0 58 53.53 0.8044 0.0 5.200 4.183 Vel = 19.87 0.0 53.53 27.030 K Factor= 10.30 68 54.50 1.049 T 5.0 0.200 23.674 K Factor= 11.20 to 120.0 0.0 5.000 0.0 63 54.5 0.8313 0.0 5.200 4.323 Vel= 20.23 0.0 54.50 27.997 K Factor= 10.30 56 18.28 2.067 0.0 8.330 26.168 vY _ to 120.0 0.0 0.0 0.0 61 18.28 0.0041 0.0 8.330 0.034 Vel = 1.75 0.0 18.28 26.202 K Factor= 3.57 69 55.34 1.049 2E 4.0 10.750 24.411 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 70 55.34 0.8551 0.0 19.750 16.889 Vel= 20-54 70 -19.29 2.067 0.0 26.840 40.291 -✓� to 120.0 0.0 0.0 0.0 71 36.05 0.0142 0.0 26.840 0.382 Vel= 3.45 71 55.60 2.067 T 10.0 115.270 40.673 to 120.0 0.0 10.000 0.0 72 91.65 0.0800 0.0 125.270 10.018 Vel= 8.76 72 0.0 2.157 T 12.307 1.880 50.691 to 120.0 0.0 12.307 0.814 18 91.65 0.0650 0.0 14.187 0.922 Vel= 8.05 0.0 91.65 52.427 K Factor= 12.66 73 55.60 1.049 2E 4.0 10.750 24.644 K Factor= 11.20 to 120.0 T 5.0 9.000 -1.009 71 55.6 0.8627 0.0 19.750 17.038 Vel= 20.64 _ ____ 0.0 55.60 40.673 K Factor= 8.72 - 70 19.28 2.067 T 10.0 24.270 40.291 to 120.0 0.0 10.000 0.0 74 19.28 0.0045 0.0 34.270 0.153 Vel = 1.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 11 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 74 0.0 2.157 T 12.307 1.880 40.444 to 120.0 0.0 12.307 0.814 45 19.28 0.0037 0.0 14.187 0.052 Vel= 1.69 0,0 19.28 41.310 K Factor= 3.00 44 30.25 4.26 0.0 12.750 41.239 to 120.0 0.0 0.0 0.0 7 30.25 0.0003 0.0 12.750 0.004 Vet= 0.68 0.0 30.25 _ 41.243 K Factor= 4.71 46 88.46 4.26 0.0 12.500 41.399 to 120.0 0.0 0.0 0.0 75 88.46 0.0022 0.0 12.500 0.028 Vel= 1.99 75 0.0 2.157 T 12.307 1.880 41.427 to 120.0 0.0 12.307 -0.814 76 88.46 0.0608 0.0 14.187 0.863 Vet= 7.77 76 0.0 2.067 2T 20.0 166.380 41.476 to 120.0 0.0 20.000 0.0 77 88.46 0.0749 0.0 186.380 13.959 Vel= 8.46 77 0.0 2.157 T 12.307 1.880 55.435 to 120.0 0.0 12.307 0.814 20 88.46 0.0608 0.0 14.187 0.863 Vel= 7.77 0.0 88.46 57.112 K Factor= 11.71 9 53.57 2.157 T 12.307 1.880 41.893 to 120.0 0.0 12.307 -0.814 78 53.57 0.0240 0.0 14.187 0.341 Vel= 4.70 78 0.0 2.067 2T 20.0 166.370 41.420 to 120.0 0.0 20.000 0.0 79 53.57 0.0296 0.0 186.370 5.518 Vel= 5.12 79 0.0 2.157 T 12.307 1.880 46.938 to 120.0 0.0 12.307 0.814 14 53.57 0.0241 0.0 14.187 0.342 Vel= 4.70 0.0 53.57 _ 48.094 K Factor= 7.72 10 301.94 4.26 0.0 12.500 42.249 to 120.0 0.0 0.0 0.0 80 301.94 0.0214 0.0 12.500 0.268 Vel= 6.80 80 -254.50 2.157 T 12.307 1.880 42.517 to 120.0 0.0 12.307 -0.814 81 47.44 0.0192 0.0 14.187 0.273 Vel= 4.17 81 0.0 2.067 2T 20.0 166.370 41.976 to 120.0 0.0 20.000 0.0 82 47.44 0.0236 0.0 186.370 4.407 Ve1= 4.54 82 0.0 2.157 T 12.307 1.880 46.383 to 120.0 0.0 12.307 0.814 83 47.44 0.0192 0.0 14.187 0.273 Vel= 4.17 • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 12 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's 'Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 83 254.50 4.26 0,0 12.500 47.470 to 120.0 0.0 0.0 0.0 13 301.94 0.0214 0.0 12.500 0.268 Vel= 6.80 -� 0.0 301.94 47.738 K Factor= 43.70 80 254.50 4.26 0.0 12.500 42.517 to 120.0 0.0 0.0 0.0 84 254.5 0.0156 0.0 12.500 0.195 Vel= 5.73 84 -209.12 2.157 T 12.307 1.880 42.712 to 120.0 0.0 12.307 -0.814 85 45.38 0.0177 _ 0.0 14.187 0.251 Vel= 3.98 85 0.0 2.067 2T 20.0 166.380 42.149 to 120.0 0.0 20.000 0.0 86 45.38 0.0218 0.0 186.380 4.060 Vel= 4.34 86 0.0 2.157 T 12.307 1.880 46.209 to 120.0 0.0 12.307 0.814 87 45.38 0.0177 0.0 14.187 0.251 Vel= 3.98 87 209.12 4.26 0.0 12.500 47.274 to 120.0 0.0 0.0 0.0 83 254.5 0.0157 0.0 12.500 0.196 Vel= 5.73 0.0 254.50 47.470 K Factor= 36.94 84 209.13 4.26 0.0 12.500 42.712 to 120.0 0.0 0.0 0.0 " 88 209.13 0.0109 0.0 12.500 0.136 Vel= 4.71 88 -165.24 2.157 T 12.307 1.880 42.848 to 120.0 0.0 12.307 -0.814 89 43.89 _ 0.0166 0.0 14.187 0.236 Vel= 3.85 89 0.0 2.067 2T 20.0 166.380 42.270 to 120.0 0.0 20.000 0.0 90 43.89 0.0205 0.0 186.380 3.818 Vel= 4.20 90 0.0 2.157 T 12.307 1.880 46.088 to 120.0 0.0 12.307 0.814 91 43.89 0.0166 0.0 14.187 0.236 Vel= 3.85 91 165.24 4.26 0.0 12.500 47.138 to 120.0 0.0 0.0 0.0 87 209.13 0.0109 0.0 12.500 0.136 Vel= 4.71 0.0 209.13 47.274 K Factor= 30.42 88 165.23 4.26 0.0 25.000 42.848 to 120.0 0.0 0.0 0.0 92 165.23 0.0070 0.0 25.000 0.176 Vel= 3.72 92 -123.32 2.157 T 12.307 1.880 43.024 to 120.0 0.0 12.307 -0.814 93 41.91 0.0153 0.0 14.187 0.217 Vel= 3.68 93 0.0 2.067 2T 20,0 166.380 42.427 to 120.0 0.0 20.000 0.0 94 41.91 0.0188 0.0 186.380 3.505 Vel= 4.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 13 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 94 0.0 2.157 T 12.307 1.880 45.932 to 120.0 0.0 12.307 0.814 95 41.91 0.0153 0.0 14.187 0.217 Vel= 3.68 95 123.32 4.26 0.0 25.000 46.963 to 120.0 0.0 0.0 0.0 91 165.23 0.0070 0.0 25.000 0.175 Vel= 3.72 0.0 165.23 47.138 K Factor= 24.07 92 123.32 4.26 0.0 12.500 43.024 to 120.0 0.0 0.0 0.0 96 123.32 0.0041 0.0 12.500 0.051 Vel= 2.78 96 -82.00 2.157 T 12.307 1.880 43.075 to 120.0 0.0 12.307 -0.814 97 41.32 0.0149 0.0 14.187 0.211 Vel= 3.63 97 0.0 2.067 2T 20.0 166.380 42.472 to 120.0 0.0 20.000 0.0 98 _ 41.32 0.0183 0.0 186.380 3.414 Vel= 3.95 98 0.0 2.157 T 12.307 1.880 45.886 to 120.0 0.0 12.307 0.814 99 41.32 0.0149 0.0 14.187 0.211 Vel = 3.63 99 82.00 4.26 0.0 12.500 46.911 to 120.0 0.0 0.0 0.0 95 123.32 0.0042 0.0 12.500 0.052 Vel= 2.78 0.0 123,32 46.963 K Factor= 18.00 96 82.00 4.26 0.0 12.500 43.075 to 120.0 0.0 0.0 0.0 100 82.0 0.0019 0.0 12.500 0.024 Vel= 1.85 100 -40.96 2.157 T 12.307 1.880 43.099 to 120.0 0.0 12.307 -0.814 101 41.04 0.0147 0.0 14.187 0.209 Vel= 3.60 101 0.0 2.067 2T 20.0 166.380 42.494 to 120.0 0.0 20.000 0.0 102 41.04 0.0181 0.0 186.380 3.371 Vel= 3.92 102 0.0 2.157 T 12.307 1.880 45.865 to 120.0 0.0 12.307 0.814 103 41.04 0.0147 0.0 14.187 0.208 Vel= 3.60 _______ 103 40.96 4.26 0.0 12.500 46.887 to 120.0 0.0 0.0 0.0 99 82.0 0.0019 0.0 12.500 0.024 Vel= 1.85 0.0 82.00 46.911 K Factor= 11.97 100 40.96 4.26 0.0 12.500 43.099 to 120.0 0.0 0.0 0.0 104 40.96 0.0006 0.0 12.500 0.007 VeI= 0.92 104 0.0 2.157 T 12.307 1.880 43.106 to 120.0 0.0 12.307 -0.814 105 40.96 0.0147 0.0 14.187 0.208 Vel= 3.60 Computer Programs by Hydratec Inc. Route 111 Windham N.H.USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 14 155400-QCD-FRZR-HIGHPILE-4 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes • Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 105 0.0 2.067 2T 20.0 166.380 42.500 to 120.0 0.0 20.000 0.0 106 40.96 0.0180 0.0 186.380 3.359 Vel = 3.92 106 0.0 2.157 T 12.307 1.880 45.859 to 120.0 0.0 12.307 0.814 107 40.96 0.0147 0.0 14.187 0.208 Vel= 3.60 107 0.0 4.26 0.0 12.500 46.881 to 120.0 0.0 0.0 0.0 103 40.96 0.0005 0.0 12.500 0.006 Vel= 0.92 0.0 40.96 46.887 K Factor= 5.98 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087