Loading...
Report , ivtu 20 I.Sq 9z/-0 6u) 1411 4IW Precisionaire NorthWest Independent H.V.A.C. Systems Testing and Balancing OR CCB #0111307 • WA PRECIN*915CS P.O. BOX 341, Canby, OR 97013 Office 503-651-3120 Facsimile 503-651-3122 TEST AND BALANCE REPORT WASHINGTON SQUARE MALL#K06 PROJECT: THE DUCK STORE LOCATION: Tigard, Oregon ARCHITECT: Ankrom Moisan Architects ENGINEER: HVAC, Inc. CONTRACTOR: Perlo Construction Company MECHANICAL: HVAC, Inc. iso PROJECT PERFO ' ; ANCE GUARANTY Pursuant to the agreement between: PRECISIONAIRE NORTHWEST And HVAC, Inc. The above testing and balancing agency will test and balance all systems in accordance with the plans and specifications as prepared by; Ankrom Moisan Architects, Inc. All systems as outlined in these specifications shall be balanced to optimum performance capabilities of the design and equipment. Testing and balancing shall be done in the accordance as published by the Industry Standards. { As part of this performance guaranty,the Engineer,or Architect may call upon Precisionaire Northwest to assist them with all technical or field problems pertaining to the final balanced condition of the system.No extra charges will be made for these services. PROJECT: THE DUCK STORE— WASHINGTON SQUARE MALL #K06 LOCATION: Tigard, Oregon ENGINEER: HVAC, Inc. GENERAL: Perlo Construction Company Guarantee Period: 1 Year Completion Date: September 15, 2015 OR CCB #111307 WA PRECIN*915CS PRECISIONAIRE NORTHWEST P.O. Box 341 Canby,OR 97013 Office(503)651-3120 Email: pnw(a�canby.com Facsimile(503)651-3122 1 BT , e; i 1 ! 1 cisionairo NorthWest Independent H.V.A.C.Testing &Balancing Project: THE DUCK STORE -WASHINGTON SQUARE MALL System: (E)VAV-1 DIRECT DRIVE FAN TEST Manufacturer: TRANE Model Number: YZD408A-VPEF Serial Number: R07L78412A Specified Actual Specified Actual !Total CFM 2000 1925 Static Pressure I (E) I Motor Amperage 4.3 1.6 Motor Voltage 115-1-60 119-1-60 Horse Power 1/3. ! 1/3. -' Service Factor ! 1 Speed Tap Set On I SPEED CONTROLLER ANNOTATION: ANNOTATION: VAV-1 DD 1 PRW precisionairo NorthWest Independent A.V.A_C.Testing &Balancing Project: THE DUCK STORE-WASHINGTON SQUARE MALL System (E)VAV-1 SUPPLY AIR DISTRIBUTION TEST SHEET Terminal Room Terminal Factor Design Test 1 Test 2 Final Number Number Code Size FPM CFM FPM CFM FPM CFM FPM CFM % 1 HALL CD-1 6" R 1 50 50 54 54 - 55 55 110% 2 Office CD-1 8" R 1 250 250 220 220 - 240 240 96% 3 Sales CD-2 12x12 1 250 250 240 240 - 245 245 98% 4 Sales CD-2 12x12 1 250 250 230 230 - 240 240 96% 5 Sales CD-2 12x12 1 250 250 230 230 - 230 230 92% 6 Sales CD-2 12x12 1 250 250 245 245 - 250 250 100% 7 Sales CD-2 12x12 1 250 250 225 225 - 230 230 92% 8 Sales CD-2 12x12 1 250 250 220 220 - 240 240 96% 9 Entry CD-2 8x8 1 1100 100 140 140 - 100 100 100% 10 Entry CD-2 8x8 1 100 100 130 130 - 95 95 95% TOTALS 2000 1934 0 1925 96% ANNOTATION: VAV-1 AD SA 1 P*iv Previsional,. North West Independent H,V.A.C.Testing &Balancing ,r Project THE DUCK STORE-WASHINGTON SQUARE MALL ELECTRIC COIL/DUCT HEATER TEST REPORT Rated Actual Volts/ Voltage Amperage Location Model No. KW Stages Phase Amps T1-T2 T2-T1 T3-T1 T1 T2 T3 (E)VAV-1 VPEF 11 2 208-3 30.5 212 215 213 30.7 31.1 30.6 VAV-1 EDH 1. N Precisiona e Bit orthWest _ Independent H.V.'.C.Testing&Balancing T B.AL.AN$1 LEGEND 0 = DENOTES SUPPLY AIR TERMINAL = D ENO IES RETURN AIR TERMINAL = 1 NOTES EXHAUST MR TERMINAL Email: pawl)canby.com P.O. Box 341 o Canby, OR 97013 o Office 503-6''i-3120 a Facsimile 503-651-3122 0 CCB# 111307