Loading...
Specifications FPS?-ol S',vo1 6,/ l i3 ytp sw 7 sie( RECEIVED OCT 7 2015 W Y A T T CITY OF TIGARD FIRE PROTECTION, INC. BUILDING DIVISION 9095 SW Burnham Street; Tigard, Oregon 97223 PHONE (503)684-2928 Leif's Paint Booths 14344 SW 72nd Avenue Tigard, Oregon ,(,0 PR OFess 12089PE 4t- �r OREGON • 46' ,1r20 4°J p� /q N C 5 EXPIRES: 12/31/2016 FIRE PROTECTION HYDRAULIC CALCULATIONS HYDRANT FLOW REQUEST FORM PROJECT: City Of Tigard flow ADDRESS: 6713 SW BONITA RD TIGARD OR CROSS STREET: FLOW HYDRANT LOCATION: 6713 SW BONITA STATIC: 105 RESIDUAL: 98 GPM: 1680 DATED: 06.17.13 RESIDUAL HYDRANT LOCATION: 6777 SW BONITA RD STATIC: 105 RESIDUAL: 103 GPM: DATED: 06.17.13 14160 14150 1 ' 14160 j 14200 IL 4. a U N 13280 6713 idp 671:3 6713 671:3 6713 • 4 . r•1 Flow Hydrant w > .: Q r 0 Z Q_ Io tom'N . „ 1 •1111 Monitor Hyd.r N 6777 6777 6777 6777 1225 N. U CL BONITA RD Ea -- - 16" DIP 24" DIP -- 14529 + > + 16"-DIP -- 14600 d a U tr) 41 6750 z w= - Feet cn ,1461 C 2=c fLl 6830 6' DIP ; I_■1 1 . . . . . . . • Water Availability Curve 110�— 100 l 90 an � 70 � p, *» D oo 40 30 ^ ` zo ` 18 | / / 'r-- / / | 800 1600 2400 3200 4000 4800 5600 *400 7200 800 Flow(GPM) ▪ Static=105 psi. • Residual 98 psi at a flow of 1680 gpm. Hydraulic Calculations for Project Name: Leifs Paint Booth Addition Location: 14344 SW 72nd Ave, Tigard, Oregon, Drawing Name: Leifs Il.cad Calculation Date: 10/7/2015 Design Remote Area Number: 1 Remote Area Location: Large Paint Booth Occupancy Classification: Extra Hazard Group II Density: 0.400gpm/ft2 Area of Application: 425.44ft2(Actual 425.44ft2) Coverage per Sprinkler: 72.25ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 13 Type of System: Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 500.00 at Node: 19 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 19: 1110.07 @ 88.244 Water Supply Information: Name of Contractor: Wyatt Fire Protection, Inc. ' Address: 9095 SW Burnham Street, Tigard, OR 97223 Phone Number: (503)684-2928 Name of designer: M. Walter, SET Authority Having Jurisdiction: Tualatin Valley F/R Notes: M.E.P.CAD, Inc. ���AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:05:37AM Page 1 Hydraulic Graph Job Name: Leifs Paint Booth Addition N 1.85 Remote Area Number: 1 150 135 120 Static Pressure 105.000 105 _T,1680.00 2 103.000— 1110.07 rg 104.071 90 610.07 @ 88.244 • •N 1110.07 with Hose Allowance at Source a 2 75 In In a 60 System demand curve 45 • 30 15 0 III11111111 1 111111111 I I I I 1 1 I I I I I I I I I I I I _ l I I I I 1 1 1 I I I I 11 I 11 I I 1 1 I 1 l 1 1 1 1 I 1 I 1 1 1 1 I 0350 700 1050 1400 1750 2100 2450 2800 Flow-gpm �©M.E.P.CAD, Inc. 'in AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:04AM Hydraulic Graph Job Name: Leifs Paint Booth Addition N 1 85 Remote Area Number: 1 150 135 120 Static Pressure 105.000 105 _� 1680.00 103.000 1110.07 104.071—∎ 90 610.07 88. .N 1110.07 with Hose Allowance at Source 75 U rn a 60 System demand curve 45 30 15 0 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IL 1 1 1 1 1 1 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0350 700 1050 1400 1750 2100 2450 2800 • Flow-gpm (N,©M.E.P.CAD, Inc. !;i5 AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:04AM 8011 Summary Of Outflowing Devices Job Number 15-1097-WF Report Description:Extra Hazard Group II(1) Actual Flow Minimum Flow K-Factor Pressure • Device (qpm) I (Wm) (K) (psi) c Sprinkler 101 28.90 F 28.90 5.6 26.633 Sprinkler 102 45.23 28.90 8 31.960 • Sprinkler 103 45.62 28.90 8 32.520 Sprinkler 104 45.84 28.90 8 1 32.836 _ Sprinkler 105 46.32 28.90 8 33.525 Sprinkler 106 46.82 28.90 8 34.254 _ Sprinkler 107 47.69 28.90 _ 8 I 35.537 Sprinkler 108 47.71 28.90 8 35.562 Sprinkler 109 48.00 28.90 8 36.002 Sprinkler 110 51.20 28.90 8 40.953 Sprinkler 111 51.60 28.90 8 41.602 Sprinkler 112 52.37 28.90 8 42.847 Sprinkler 113 52.78 28.90 8 43.524 Most Demanding Sprinkler Data bh,©M.E.P.CAD, Inc. Aid AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:19AM Page 3 Job Name: Leifs Paint BoothAddition Remote Area Number: 1 Date: 10/7/2015 Supply Analysis Anal sis Static Residual Flow Available Total Demand Required Pressure Node Name (Psi) (Psi) (gpm) (Psi) (gpm) (Psi) 19 Water Supply 105.000 103.000 1680.00 104.071 1110.07 88.244 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes • Node Node (Psi) (gpm) 19 -4'-0 Supply 88.244 610.07 101 19'-0 Sprinkler 26.633 28.90 102 9'-3 Sprinkler 31.960 45.23 103 10'-10 Sprinkler 32.520 45.62 104 10'-10 Sprinkler 32.836 45.84 105 10'-10 Sprinkler 33.525 46.32 106 9'-3 Sprinkler 34.254 46.82 107 10'-10 Sprinkler 35.537 47.69 108 10'-10 Sprinkler 35.562 47.71 109 10'-10 Sprinkler 36.002 48.00 110 9'-3 Sprinkler 40.953 51.20 111 9'-3 Sprinkler 41.602 51.60 112 9'-3 Sprinkler 42.847 52.37 113 9'-3 Sprinkler 43.524 52.78 1 19'-0 28.097 2 11'-4 33.906 3 11'-4 34.029 4 11'-4 34.360 • 5 11'-4 35.103 ,©M.E.P.CAD, Inc. qn AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:25AM Page 4 Job Name: Leifs Paint BoothAddition Remote Area Number: 1 Date: 10/7/2015 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 6 11'-4 35.224 7 10'-0 45.974 8 10'-0 46.701 9 16'-0 75.687 10 16'-0 75.766 11 16'-0 75.852 12 16'-0 75.937 13 16'-0 76.024 14 16'-0 76.112 15 16'-0 76.203 16 16'-0 77.300 17 10'-0 81.756 18 l'-0 85.899 20 11'-4 33.796 21 11'-4 34.125 22 11'-4 34.843 23 11'-4 37.793 24 11'-4 36.940 25 11'-4 37.219 26 11'-4 37.702 27 11'-4 36.966 28 11'-4 37.424 29 10'-0 44.881 &©M.E.P.CAD, Inc. AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:25AM Page 5 Job Name: Leifs Paint BoothAddition Remote Area Number: 1 Date: 10/7/2015 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 30 10'-0 45.592 31 10'-0 44.640 32 10'-0 45.347 33 16'-0 75.687 34 16'-0 75.687 35 16'-0 75.687 36 16'-8 75.406 37 16'-8 75.569 38 16'-0 75.865 39 16'-0 75.866 40 16'-0 75.866 41 16'-0 75.868 42 16'-0 75.870 43 16'-0 75.872 44 17'-8'/z 75.135 45 17'-8/ 75.194 46 16'-0 75.874 47 17'-11 75.050 48 17'-11 75.186 49 16'-0 75.875 50 18'-1'/: 74.965 51 18'-11/2 75.179 52 17'-6 75.203 (,©M.E.P.CAD, Inc. yy AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:25AM Page 6 Job Name: Leifs Paint Booth Addition Remote Area Number: 1 Date: 10/7/2015 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node • (Psi) (gpm) 53 17'-6 75.219 54 17-3',4 75.211 55 17'-3'/z 75.303 56 17'-1 75.225 57 17'-1 75.389 58 16'-10'/z 75.316 59 16'-10'/z 75.478 60 16'-0 75.875 61 18'-4 74.880 62 18'-4 75.175 ,©M.E.P.CAD, Inc. 4 AutoSPRINK®12 v12.0.29.0 10/7/2015 7:06:25AM Page 7 JODName: LeITs FaintbOotnAddition Remote Area Number: 1 Date: 10/7/2015 • Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) this step 1 (Foot) K-Factor p Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total Foot (psi) to(Pf)and shown as a (Foot) (Q) (Foot) (Foot) Friction(Pf) negative value. 101 19'-0 5.6 28.90 1 (See 0'-6 100 26.633 Route 1 Notes) Sprinkler, 3'-7 1 19'-0 28.90 1.0490 4 1 0.360266 1.464 T(3'-7) 1 19'-0 1 (See 7'-8 120 28.097 Notes) 2'-0 3.323 2 11'-4 28.90 1.0490 9 8 0.257121 2.485 E(2'-0) 2 11'-4 2 (See 2'-111/2 120 33.906 Notes) 10'-0 3 11'-4 28.90 2.0670 0.009454 T(10'-0) 12'-11/z 0.123 3 11'-4 45.62 2 6'-1 120 34.029 Flow(q)from Route 3 4 11'-4 74.52 2.0670 6 0.054533 '-1 0.332 4 11'-4 45.84 2 5'-7% 120 34.360 Flow(q)from Route 4 • 5 11'-4 120.36 2.0670 0.132391 5'-7/2 0.743 5 11'4 46.32 2 0'-6 120 35.103 Flow(q)from Route 5 6 11'-4 166.68 2.0670 0.241794 0'-6 0.121 6 11'-4 45.23 2 (See 7'-0 120 35.224 Notes) Flow(q)from Route 2 20'-0 0.577 0.376986 2E(5'0), PO(10'0) 7 10'-0 211.91 2.0670 27'-0 10.173 7 10'-0 103.56 3 8'-6 120 45.974 Flow(q)from Route 10 8 10'-0 315.47 3.2600 - 0.085578 8'-6 0.727 8 10'-0 190.22+104.3E 3 (See 41'-g 120 46.701 Notes) Flow(q)from Route 6 and 11 67-2% -2.601 0.289892 5fE(6'8'/2), BV(13' 5'h), 9 16'-0 610.07 3.2600 108' 11'/: 31.587 mecT(20'-2) 9 16'-0 6 7'-7 120 75.687 10 16'-0 588.34 6.3570 0.010486 7'-7 0.079 10 16'0 6 8'-4 120 75.766 11 16'-0 583.01 6.3570 0.010311 8'-4 0.086 bk,©M.E.P.CAD, Inc. in AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 8 JoD Name: LeI1S l'alnt1300tHHOUltlon Remote Area Number: 1 Date: 10/7/2015 Pipe Information Flow added Length C Factor Notes Elev I Fittings& Total(Pt) Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) - (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Loss Per Unit Elev 2 Total Flow qurv. (Foot) L P applicable,are added directly Node 2 Actual ID Length Total (Foot) (0) (Foot) Foot (psl) Friction(Pf) to(Pf)and shown as a ( ) negative value. 11 16'-0 6 8'-4 120 75.852 12 16'-0 580.95 6.3570 - 0.010244 - 8'-4 0.085 12 16'-0 4.19 6 8-4 120 75.937 Flow(q)from Route 14 13 16'-0 585.14 6.3570 8 0.010381 '-4 0.087 13 16'-0 6.56 6 8'-4 120 76.024 Flow(q)from Route 15 14 16'-0 591.69 6.3570 8 0.010597 '-4 0.088 14 16'-0 8.39 6 8'-4 120 76.112 Flow(q)from Route 16 - 15 16'-0 600.09 6.3570 0.010877 8'-4 0.091 15 16'-0 9.98 6 (See 75'-2% 120 76.203 Notes) Flow(q)from Route 21 22'-7% 16 16'-0 610.07 6.3570 0.011214 - 2LtE(11'-4) 97'-10 1.097 16 16'-0 6 (See 120'-1 120 77.300 . Notes) 45'-3 2.601 • 17 10'-0 610.07 6.3570 0.011214 -- 4LtE(11'-4) 165-4% 1.854 17 10'-0 6 (See 9'-0 120 81.756 Notes) 12'-7 3.902 0.011214 2f(-0.000),BV(12'-7) 18 1'-0 610.07 6.3570 21'_7 0.242 18 1'-0 8 (See 45'-0 150 85.899 Notes) 27'-2 2.168 19 -4'-0 610.07 7.9800 0.002452 E(27'-2), S 72'-2 0.177 500.00 88.244 Hose Allowance At Source 19 1110.07 Total(Pt) Route 1 102 9'-3 8 45.23 1 (See 2'-0% 120 31.960 Route 2 Notes) Sprinkler, 5'-0 -0.894 6 11'-4 45.23 1.0490 0.588781 T(5'-0) 7'-0/: 4.158 35.224 Total(Pt) Route 2 103 10'-10 8 45.62 1 (See 0'-6 120 32.520 Route 3 Notes) Sprinkler, 2'-0 -0.209 20 11'-4 45.62 1.0490 2'6 0.598315 1.485 E(2'-0) 0 M.E.P.CAD,Inc. y Auto SPRINKO 12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 9 Job Name: Leifs Paint BoothAddition Remote Area Number: 1 Date: 10/7/2015 Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) this step 1 (Foot) K-Factor p Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total Foot (psi) to(Pf)and shown as a (Foot) (Q) (Foot) (Foot) Friction(Pf) negative value. 20 11'-4 2 (See 0'-7 120 33.796 Notes) 10,-0 3 11'-4 45.62 2.0670 10'7 0.021999 0.233 T(10'-0) 34.029 Total(Pt) Route 3 104 10'-10 8 45.84 1 (See 0'-6 120 32.836 Route 4 Notes) Sprinkler, 2'-0 -0.209 21 11'-4 45.84 1.0490 0.603696 E(2'-0) 2'-6 1.498 21 11'-4 2 (See 0'-7 120 34.125 Notes) 10'-0 4 11'-4 45.84 2.0670 10'-7 0.022197 0.235 T(10'-0) 34.360 Total(Pt) Route 4 105 10'-10 8 46.32 1 (See 0'-6 120 33.525 Route 5 Notes) Sprinkler, 2'-0 -0.209 22 11'-4 46.32 1.0490 2 6 0.615396 1 527 E(2'-0) 22 11'-4 2 (See 1'-6 120 34.843 Notes) 10'-0 5 11'-4 46.32 2.0670 0.022627 T(10'-0) 11'-6 0.260 35.103 Total(Pt) Route 5 106 9'-3 8 46.82 1 (See 2'-0'% 120 34.254 Route 6 Notes) Sprinkler, 5'-0 -0.894 23 11'-4 46.82 1.0490 0.627771 T(5'-0) 7'-01/2 4.433 23 11'-4 143.40 2 (See 7'-0 120 37.793 Notes) Flow(q)from Route 7 20'-0 0.577 0.308723 2E(5'0), PO(10'0) 8 10'-0 190.22 2.0670 27'-0 8.331 46.701 Total(Pt) Route 6 • 107 10'-10 8 47.69 1 (See 0'-6 120 35.537 Route 7 Notes) Sprinkler, 2'-0 -0.209 24 11'-4 47.69 1.0490 2-6 0.649492 1.612 E(2'-0) 24 11'-4 2 (See 6'-8 120 36.940 Notes) 5'-0 - 25 11'-4 47.69 2.0670 0.023880 E(5'-0) 11'-8 0.279 �i ©M.E.P.CAD, Inc. 111 AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 10 Job Name: Leirs PaintBoothAddition Remote Area Number: 1 Date: 10/7/2015 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) - Length) Fitting Pf Friction Elev Pe ( ► Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 5'-7% 120 37.219 25 11'-4 47.71 2 Flow(q)from Route 8 26 11'-4 95.40 2.0670 0.086117 5'-7/2 0.483 0'-6 120 37.702 26 11'-4 48.00 2 Flow(q)from Route 9 - 23 11'-4 143.40 2.0670 0.183042 0'-6 0.092 37.793 Total(Pt) Route 7 108 10'-10 8 47.71 1 (See 0'-6 120 35.562 Route 8 Notes) Sprinkler, 2'-0 -0.209 27 11'-4 47.71 1.0490 2'6 0.649909 1.613 E(2'-0) 27 11'-4 2 (See 0'-7 120 36.966 Notes) 10,-0 25 11'-4 47.71 2.0670 10'-7 0.023896 0.253 T(10'-0) 37.219 Total(Pt) Route 8 109 10'-10 8 48.00 1 (See 0'-6 120 36.002 Route 9 Notes) Sprinkler, 2'-0 -0.209 28 11'-4 48.00 1.0490 2'6 0.657340 1.631 E(2'-0) 28 11'-4 2 (See 1'-6 120 37.424 Notes) 10'-0 26 11'-4 48.00 2.0670 11'6 _ 0.024169 0.278 1(10'-0) 37.702 Total(Pt) Route 9 ' 110 9'-3 8 51.20 1 (See 0'-9 120 40.953 Route 10 Notes) Sprinkler, 5'-0 -0.317 29 10'-0 51.20 1.0490 ._ - 0.740561 T(5'-0) 5'-9 4.245 '-11 120 44.881 29 10'-0 52.37 2 (See 0 Flow(q)from Route 12 Notes) 10'-0 7 10'-0 103.56 2.0670 0.100246 PO(10'0) 10'-11 1.093 45.974 Total(Pt) Route 10 111 9'-3 8 51.60 1 (See 0'-9 120 41.602 Route 11 Notes) Sprinkler, ` 5'-0 -0.317 - 30 10'-0 51.60 1.0490 5 9 0.751413 4.307 T(5'-0) �i,0 M.E.P.CAD,Inc. 4111 AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 11 Job Name: Leifs Paint Booth Addition Remote Area Number: 1 Date: 10/7/2015 Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 30 10'-0 52.78 2 (See 0,-11 120 45.592 Notes) Flow(q)from Route 13 10'-0 8 10'-0 104.38 2.0670 0.101713 P0(10.-0) 10'-11 1.109 46.701 Total(Pt) Route 11 112 9'-3 8 52.37 1 (See 0'-9 120 42.847 Route 12 Notes) Sprinkler, 2'-0 -0.317 0.772187 31 10'-0 52.37 1.0490 2,_9 2.109 E(2'-0) 8'-6 120 44.640 31 10'-0 2 29 10'-0 52.37 2.0670 0.028392 '-6 0.241 44.881 Total(Pt) Route 12 113 9'-3 8 52.78 1 (See 0'-9 120 43.524 Route 13 Notes) Sprinkler, 2'-0 -0.317 32 10'-0 52.78 1.0490 2'9 0.783466 2.140 E(2'-0) 8'-6 120 45.347 32 10'-0 2 30 10'-0 52.78 2.0670 0.028806 8'-6 0.245 45.592 Total(Pt) Route 13 9 16'-0 6 0'-9 120 75.687 Route 14 33 16'-0 21.73 6.3570 0.000023 0'-9 0.000 8'-4 120 75.687 33 16'-0 6 34 16'-0 14.48 6.3570 0.000011 8'-4 0.000 34 16'0 6 8'-4 120 75.687 • 35 16'-0 7.24 6.3570 0.000003 8'-4 0.000 35 16'-0 2 (See 0'-8 120 75.687 Notes) P0(10'-0) 10'-0 -0.289 36 16'-8 7.24 2.0670 0.000731 10'-8 0.008 36 16'-8 2 (See 213'0 120 75.406 Notes) E(5'-0) 10'-0 -37 16'-8 7.24 2.0670 0.000731 E(5'-0) 223'-0 0.163 ,,©M.E.P.CAD, Inc. In AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 12 Job Name: Leifs PaintBoothAddition Remote Area Number: 1 Date: 10/7/2015 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 37 16-8 2 (See 0'-8 120 75.569 Notes) 10'-0 0.289 38 16'-0 7.24 2.0670 10'-8 0.000731 0.008 P0(10.-0) 38 16'-0 4 8'-4 120 75.865 • 39 16'-0 7.24 4.2600 0.000022 8'-4 0.000 39 16'-0 7.24 4 8'4 120 75.866 Flow(q)from Route 20 40 16'-0 14.48 4.2600 0.000078 8'-4 0.001 40 16'-0 7.25 4 8'4 120 75.866 Flow(q)from Route 19 - 41 16'-0 21.73 4.2600 0.000165 8'-4 0.001 41 16'-0 5.32 4 8'-4 120 75.868 Flow(q)from Route 18 - • 42 16'-0 27.06 4.2600 0.000247 8'-4 0.002 42 16'-0 2.07 4 8'4 120 75.870 Flow(q)from Route 17 43 16'-0 29.12 4.2600 0.000283 8'-4 0.002 43 16'-0 2 (See 1'-81/2 120 75.872 Notes) P0(10'-0) 10'-0 -0.740 44 17'-8'/ 4.19 2.0670 0.000265 11'-8% 0.003 44 17'-8% 2 (See 213'-0 120 75.135 Notes) E(5'-0) 10'-0 45 17'-8Y: 4.19 2.0670 0.000265 - E(5'-0) 223'-0 0.059 45 17-8'/2 2 (See 1'-8% 120 75.194 • Notes) 10'-0 0.740 12 16'-0 4.19 2.0670 0.000265 PO(10'0) 11'-81/2 0.003 75.937 Total(Pt) Route 14 43 16'-0 4 8'-4 120 75.872 Route 15 - 46 16'-0 24.94 4.2600 0.000213 8'-4 0.002 46 16'-0 2 (See 1'-11 120 75.874 Notes) P0(10'-0) 10'-0 -0.831 47 17'-11 6.56 2.0670 0.000608 11'-11 0.007 (i,©M.E.P.CAD,Inc. ill AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 13 Job Name: Leifs PaintBoothAddition Remote Area Number: 1 Date: 10/7/2015 • Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 47 17'-11 2 (See 213'-0 120 75.050 Notes) E(5'-0) 10'-0 48 17'-11 6.56 2.0670 0.000608 E(5'-0) 223'-0 0.136 48 17'-11 2 (See 1'-11 120 75.186 Notes) 10'-0 0.831 • 13 16'-0 6.56 2.0670 — 0.000608 • P0(10'-0) 11'-11 0.007 76.024 Total(Pt) Route 15 46 16'-0 4 8'-4 120 75.874 Route 16 49 16'-0 18.38 4.2600 0.000121 8'-4 0.001 49 16'-0 2 (See 2'-1% 120 75.875 Notes) P0(10'-0) 10'-0 -0.921 50 18'-11/2 8.39 2.0670 0.000960 12'-1% 0.012 50 18'-11A 2 (See 213'-0 120 74.965 Notes) E(5'-0) 10'-0 51 18'-1% 8.39 2.0670 0.000960 E(5'-0) 223'-0 0.214 51 18'-1% 2 (See 2'-1% 120 75.179 Notes) 10'-0 0.921 14 16'-0 8.39 2.0670 0.000960 PO(10'-0) 12'-1% 0.012 76.112 Total(Pt) Route 16 11 16'-0 2 (See 1'-6 120 75.852 Route 17 Notes) PO(10'-0) 10'-0 -0.650 52 17'-6 2.07 2.0670 0.000072 11'-6 0.001 52 17'-6 2 (See 213'-0 120 75.203 Notes) E(5'-0) 10,-0 53 17'-6 2.07 2.0670 0.000072 E(5'-0) 223'-0 0.016 • 53 17'-6 2 (See 1'-6 120 75.219 Notes) 10'-0 0.650 42 16'-0 2.07 2.0670 11'6 0.000072 0.001 P0(10'-0) 75.870 Total(Pt) Route 17 10 16'-0 2 (See 1'-3% 120 75.766 Route 18 Notes) P0(10'-0) 10'-0 -0.560 54 17'-3% 5.32 2.0670 0.000413 11'-3% 0.005 (,©M.E.P.CAD, Inc. in AutoSPRINKO 12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 14 .JOD Name: LeltS FaintBootnAdaltlon Remote Area Number: 1 Date: 10/7/2015 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) J Length) Fitting Pe Pt Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 54 17'-3%2 2 (See 213'-0 120 75.211 E(5'-0) Notes) 10,-0 55 17'-3'/2 5.32 2.0670 0.000413 E(5'-0) 223'-0 0.092 55 17'-3% 2 (See 1'-3%2 120 75.303 Notes) 10'-0 0.560 • 41 16'-0 5.32 2.0670 0.000413 P0(10.-0) 11'-3'/2 0.005 75.868 Total(Pt) Route 18 33 16'-0 2 (See 1'-1 120 75.687 Route 19 Notes) P0(10.-0) 10'-0 -0.470 - 56 17'-1 7.25 2.0670 0.000732 11'-1 0.008 56 17'-1 2 (See 213'4) 120 75.225 Notes) E(5'-0) 10'-0 57 17'-1 7.25 2.0670 0.000732 E(5'-0) 223'-0 0.163 57 17'-1 2 (See 1'-1 120 75.389 Notes) 10'-0 0.470 40 16'-0 7.25 2.0670 11' 1 0.000732 0.008 P0(10'-0) 75.866 Total(Pt) Route 19 34 16'-0 2 (See 0'-10% 120 75.687 Route 20 Notes) P0(10.-0) 10'-0 -0.379 58 16'-10% 7.24 2.0670 10 0.000730 '-10% 0.008 58 16'-10% 2 (See 213'4) 120 75.316 Notes) E(5'-0) 10'-0 59 16'-10'/2 7.24 2.0670 0.000730 - E(5'-0) 223'-0 0.163 59 16'-10% 2 (See 0'-10% 120 75.478 Notes) 10'-0 0.379 • 39 16'-0 7.24 2.0670 0.000730 P0(10.-0) 10'-10% 0.008 75.866 Totel(Pt) Route 20 • 49 16'-0 4 8'-4 120 75.875 Route 21 • 60 16'-0 9.98 4.2600 0.000039 8'-4 0.000 60 16'-0 2 (See 2'-4 120 75.875 Notes) P0(10'-0) 10'-0 -1.012 - 61 18'-4 9.98 2.0670 - 0.001323 12'-4 0.016 &©M.E.P.CAD, Inc. .al AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 15 Job Name: Leifs Paint Booth Addition Remote Area Number: 1 Date: 10/7/2015 • Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit Node 2 Actual ID Length Total applicable,are added directly (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pt)and shown as a (Foot) negative value. 61 18'-4 2 (See 213'-0 120 74.880 Notes) E(5'-0) 10,-0 62 18'-4 9.98 2.0670 0.001323 E(5'-0) 223'-0 0.295 62 18'-4 2 (See 2'-4 120 75.175 Notes) 10'-0 1.012 — • 15 16'-0 9.98 2.0670 12 0.001323 0.016 P0(10'-0) 76.203 Total(Pt) Route 21 ki,®M.E.P.CAD, Inc. in AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 16 JOD Name: Lelts I-'alnttSOOtnHaaltlon Remote Area Number: 1 LL Date: 10/7/2015 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) r—lC Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90°Elbow EE 45°Elbow Eel 11YP Elbow Eel 221/2 Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve _ Z Cap • �i ®M.E.P.CAD,Inc. 4J AutoSPRINK®12 v12.0.29.0 1 10/7/2015 7:06:30AM Page 17 Hydraulic Calculations for , Project Name: Leifs Paint Booth Addition Location: 14344 SW 72nd Ave, Tigard, Oregon, Drawing Name: Leifs Il.cad Calculation Date: 10/7/2015 Design Remote Area Number: 2 Remote Area Location: Small Paint Booth Occupancy Classification: Extra Hazard Group II Density: 0.400gpm/ft2 Area of Application: 111.61ft2(Actual 111.61ft2) Coverage per Sprinkler: 81.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 4 Type of System: Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 500.00 at Node: 19 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 19: 686.00 @ 84.832 Water Supply Information: Name of Contractor: Wyatt Fire Protection, Inc. Address: 9095 SW Burnham Street, Tigard, OR 97223 Phone Number: (503)684-2928 Name of designer: M. Walter, SET Authority Having Jurisdiction: Tualatin Valley F/R Notes: A M.E.P.CAD, Inc. iAutoSPRINK®12 v12.0.29.0 2 10/7/2015 7:10:05AM Page 1 Hydraulic Graph Job Name: Leifs Paint Booth Addition N 1.85 Remote Area Number: 2 150 135 120 Available Supply 105 Static Pressure 105.000 1680.00 @ 103.000 686.00 @ 104.619 1 L 90 186.001 84.832 a 686.00 with Hose Allowance at Source 75 1n 1n w 60 =S stem demand curve 45 30 15 3 0 -Mu1uuuu1 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 1 1 1 1 1 1 0350 700 1050 1400 1750 2100 2450 2800 Flow-gpm ,,©M.E.P.CAD, Inc. 4 AutoSPRINK®12 v12.0.29.0 10/7/2015 7:10:08AM 111 Summary Of Outflowing Devices 1 Job Number: 15-1097-WF Report Description:Extra Hazard Group II(2) Actual Flow Minimum Flow K-Factor Pressure • Device (cum) (cmm) (K) (Psi) b Sprinkler 201 32.40 32.40 5.6 33.474 Sprinkler 202 50.92 32.40 8 40.512 • Sprinkler 203 51.08 32.40 8 40.767 Sprinkler 204 51.60 32.40 8 41.609 c> Most Demanding Sprinkler Data &©M.E.P.CAD, Inc. rinAutoSPRINK®12 v12.0.29.0 10/7/2015 7:10:10AM Page 3 JOD Name: Lelt'S t'alnt loomFiaaition Remote Area Number: 2 Date: 10/7/2015 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) (gpm) (psi) (gpm) (psi) 19 Water Supply 105.000 103.000 1680.00 104.619 686.00 84.832 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 19 -4'-0 Supply 84.832 186.00 201 19'-0 Sprinkler 33.474 32.40 202 8'-0 Sprinkler 40.512 50.92 203 8'-0 Sprinkler 40.767 51.08 204 9'-6 Sprinkler 41.609 51.60 10 16'-0 75.908 ' 11 16'-0 75.908 12 16'-0 75.908 13 16'-0 75.908 14 16'-0 75.908 15 16'-0 75.908 16 16'-0 75.908 17 10'-0 78.716 18 1'-0 82.644 33 16'-0 75.908 34 16'-0 75.908 35 16'-0 75.908 38 16'-0 75.908 39 16'-0 75.908 (,©M.E.P.CAD, Inc. •In Auto SPRINKO 12 v12.0.29.0 10/7/2015 7:10:12AM Page 4 Job Name: Leifs Paint Booth Addition Remote Area Number: 2 Date: 10/7/2015 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 40 16'-0 75.908 41 16'-0 75.908 42 16'-0 75.908 43 16'-0 75.908 46 16'-0 75.908 49 16'-0 75.908 60 16'-0 75.908 63 19'-0 35.284 64 9'-0 44.181 65 8'-6 44.601 66 8'-6 45.613 67 3'-2 75.491 68 17'-0 73.888 69 8'-6 44.323 70 10'-0 43.265 (A,©M.E.P.CAD, Inc. 9ygAutoSPRINKO12v12.0.29.0 10/7/2015 7:10:12AM Page 5 Job Name: Leifs Paint Booth Addition Remote Area Number: 2 Date: 10/7/2015 . Pipe Information Flow added Length C Factor Notes Elev 1 Fittings& Total(Pt) this step 1 (Foot) K-Factor p Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 (Q) Actual ID Length Total Foot (psi) to(Pf)and shown as a (Foot) ( ) (Foot) (Foot) Friction(Pf) negative value. 201 19'-0 5.6 32.40 1 (See 0'-6 100 33.474 Route 1 Notes) Sprinkler, 3'-7 63 19'-0 32.40 1.0490 4'-1 0.445113 1.809 T(3'-7) 63 19'-0 1 (See 10'-41/2 120 35.284 Notes) 4'-0 4.335 0.317676 2E(2'-0) 64 9'-0 32.40 1.0490 14'-41/2 4.562 64 9'-0 2 (See 2'-5 120 44.181 Notes) 15'-0 0.217 - 0.011680 - E(5'0),T(10'0) 65 8'-6 32.40 2.0670 17'-5 0.204 65 8'-6 51.08 2 (See 5'4)'/2 120 44.601 Notes) Flow(q)from Route 3 10'-0 66 8'-6 83.48 2.0670 - 0.067277 T(10'-0) 15'-0/2 1.012 66 8'-6 102.52 2 (See 32'-1 120 45.613 Notes) Flow(q)from Route 2 61'-0 2.312 0.296180 3E(5'-0), 3T(10'-0),BV(6'-0), • 67 3'-2 186.00 2.0670 93'-1 27.565 PO(10'-0) 67 3'-2 21/2 (See 36'-7 120 75.491 Notes) 11'-91/2 -5.997 68 17'-0 186.00 2.6350 48'-5 0.090795 4.395 2fE(5' 11) 68 17'-0 212 (See 1'-0 120 73.888 Notes) 16'-51/2 0.434 16 16'-0 186.00 2.6350 0.090795 mecT(16'-5'2) 17'-5/2 1.587 16 16'-0 6 (See 120'-1 120 75.908 Notes) 45'-3 2.601 0.001246 4 LtE(11'-4) 17 10'-0 186.00 6.3570 165.-41/2 0.206 17 10'-0 6 (See 9'-0 120 78.716 • Notes) 12'-7 3.902 0.001246 2f(-0.000), BV(12'-7) 18 1'-0 186.00 6.3570 21'-7 0.027 18 1'-0 8 (See 45'-0 150 82.644 Notes) 27'-2 2.168 19 -4'-0 186.00 7.9800 72'-2 0.000272 0.020 E(27'-2), S 500.00 84.832 Hose Allowance At Source • 19 686.00 Total(Pt) Route 1 k i,©M.E.P.CAD, Inc. • AutoSPRINK®12 v12.0.29.0 2 10/7/2015 7:10:16AM Page 6 Job Name: Leifs Paint Booth Addition Remote Area Number: 2 Date: 10/7/2015 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total Foot (psi) to(Pf)and shown as a (Foot) (Q) (Foot) (Foot) Friction(Pf) negative value. 202 8'-0 8 50.92 1 (See 0'-6 120 40.512 Route 2 Notes) Sprinkler, 5'-0 -0.209 69 8'-6 50.92 1.0490 5'-6 0.733181 4.019 T(5'-0) 69 8'-6 51.60 2 (See 3'-11/2 120 44.323 Notes) . Flow(q)from Route 4 10,-0 66 8'-6 102.52 2.0670 0.098394 T(10'-0) 13'-1 h 1.291 45.613 Total(Pt) Route 2 203 8'-0 8 51.08 1 (See 0'-6 120 40.767 Route 3 Notes) Sprinkler, 5'-0 -0.209 65 8'-6 51.08 1.0490 5'-6 0.737451 4.043 T(5'-0) 44.601 Total(Pt) Route 3 204 9'-6 8 51.60 1 (See 0'-6 120 41.609 Route 4 Notes) Sprinkler, 2'-0 -0.209 70 10'-0 51.60 1.0490 2'-6 0.751518 1.865 E(2'-0) 70 10'-0 2 (See 4'-9 120 43.265 Notes) 10'-0 0.650 69 8'-6 51.60 2.0670 14'-9 0.027632 0.407 2E(5'-0) 44.323 Total(Pt) Route 4 ,,©M.E.P.CAD, Inc. in AutoSPRINK®12 v12.0.29.0 2 10/7/2015 7:10:16AM Page 7 Job Name: Leif's PaintBoothAddition Remote Area Number: 2 Date: 10/7/2015 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) r IC Value Multiplier II Actual Inside Diameter N 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90°Elbow EE 45°Elbow Eel 11W Elbow Ee2 22Y2° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap • k,©M.E.P.CAD, Inc. +•in AutoSPRINK®12 v12.0.29.0 2 10/7/2015 7:10:16AM Page 8