Specifications (16)
i %2 '1 S 6010' cett/ 72 "w RECEIVED OCT 7 2015 CITY OF TIGARD BUILDING DIVISION WYATT FIRE PROTECTION, INC. 9095 SW Burnham Street; Tigard, Oregon 97223 PHONE (503)684-2928 Leif's Paint Booths 14344 SW 72nd Avenue Tigard, Oregon _. -co G 0NINEFR (3/ 1 1 2089P yr OREGON <.4/ '9Y 20, 1g� 0� qN C. 0G' EXPIRES: 12/31/2016 FIRE PROTECTION EQUIPMENT SUBMITTAL Leif's Paint Booths 14344 SW 72nd Avenue Tigard, Oregon FIRE PROTECTION EQUIPMENT SUBMITTAL INDEX PRODUCT MAKE MODEL/DESCRIPTION 1. SPRINKLERS TYCO Series TY-B Standard Response SSP SIN #TY4251 Bronze Finish TYCO Series DS-1 Std Response Dry HSW SIN#TY3255 Bronze Finish 2. PIPING BULLMOOSE TUBE Schedule 10, Black Steel, ASTM A795 BULLMOOSE TUBE Eddyflow, Black Steel, ASTM A795 BULLMOOSE TUBE Schedule 40, Black Steel, ASTM A795 BULLMOOSE TUBE Eddythread40, Black Steel, ASTM A795 3. PIPE FITTINGS SMITH COOPER Ductile Iron, Grooved, ASTM A536 SMITH COOPER Cast Iron, Threaded, ASME B16.4 SMITH COOPER Ductile Iron, Threaded, ASTM A536 4. HANGERS COOPER B-LINE Figure 2NFPA Band Hanger Ring COOPER B-LINE Figure ATR All Thread Rod SAMMY Fasteners for Steel 5. SEISMIC EQUIP COOPER B-LINE Figure 4L Longitudinal Attachment COOPER B-LINE Figure 980 Sway Brace Attachment **The above listed items are the proposed equipment to be used on this project, however we reserve the right to use an 'equivalent'product or manufacturer at our discretion. ticsWorldwide www.tyco-fire.com Fire Protection Contacts Products Series TY-B - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General ambient temperature, concentration of chemicals, and gas/chemical velocity, Description should be considered, as a minimum, ,—. along with the corrosive nature of the TYCO Series TY-B, 2.8, 5.6, and 8.0 chemical to which the sprinklers will be K-factor, Upright and Pendent Sprin- exposed. klers described in this technical data An intermediate level version of the sheet are standard response, standard Series TY-B Pendent Sprinkler can be coverage decorative 5 mm glass bulb obtained by utilizing the Series TY-B type spray sp rinklers designed for use in Pendent Sprinkler in combination with light,ordinary,or extra hazard,commer- the Model S2 Shield. cial occupancies such as banks,hotels, ''• shopping malls,factories,refineries,and NOTICE - chemical plants. The Series TY-B Sprinklers described The recessed version of the Series TY-B herein must be installed and maintained Pendent Sprinkler, where applicable, is in compliance with this document, as intended for use in areas with a finished well as with the applicable standards of ceiling. It uses a two-piece Style 10(1/2 the National Fire Protection Association inch NPT) or Style 40 (3/4 inch NPT) (NFPA), in addition to the standards of Recessed Escutcheon. The Recessed any other authorities having jurisdiction. I / Escutcheon provides 1/2 inch(12,7 mm) y gl pr ( ) Failure to do so may impair the perfor- of recessed adjustment or up to 3/4 inch mance of these devices. (19,1 mm)of total adjustment from the flush pendent position.The adjustment The owner is responsible for maintaining provided by the Recessed Escutcheon their fire protection system and devices -� reduces the accuracy to which the fixed in proper operating condition. Contract pipe drops to the sprinklers must be cut. the installing contractor or product manufacturer with any questions. Corrosion resistant coatings, where applicable,are utilized to extend the life of copper alloy sprinklers beyond that Sprinkler which would otherwise be obtained Identification when exposed to corrosive atmo- Identification spheres. Although corrosion resistant coated sprinklers have passed the Numbers (SINs) r corrosion t t f th standard tests of the appli- cable approval agencies, the testing TY1151 - Upright 2.8K, 1/2"NPT is not representative of all possible TY1251 - Pendent 2.8K, 1/2"NPT corrosive atmospheres. Consequently, TY3151 - Upright 5.6K, 1/2"NPT it is recommended that the end user TY3251- Pendent 5.6K, 1/2"NPT be consulted with respect to the suit- TY4151 - Upright 8.0K,3/4"NPT ability of these coatings for any given TY4251 - Pendent 8.0K,3/4"NPT corrosive environment. The effects of TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.0K, 1/2"NPT IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components.Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 NOVEMBER 2014 TFP151 , TFP151 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 7 3 - Sealing 6 - Deflector* 1,ri , i1 �\ Assembly 7 - Bushing �: If 1 4 - Bulb ' 7/1 mm) (11,1 2-1/4" 3 NOMINAL l (57,2 MAKE IN 2 *Temperature rating is 1-' 10 2 3/16" ' 1-9/16" 4 indicated on Deflector. j (55,6 mm) i (39,7 mm) �' 5 ** Pipe thread connections \ E+�,,,_ 6* per ISO 7-1 can be ��•�� "� �`� 6 provided on special 1/2" NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE • 7/16" uu 3 ' (11,1 mm) NOMINAL I 2 3/16" �- -"` 2 MAKE-IN (55,6 mm) `- i k i i i 2-3/16" - - (38,1 mm) - - 5 6*ir 1/2" NPT** t WRENCH STYLE 10 2-7/8"(73,0 mm)DIA. —.- FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE M TFP151 Page 3 of 8 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE ,,,-,- -,-,,, 1 ff 1/2" 3 gril (12,7 mm) ,� A NOMINAL } 2 5/16" tal V 1 P 4 2 nit Ai MAKE IN I (58,7 mm) `-i 2-1/4" 4 S ! ' 1 9/16" (57,2 mm) (39,7 mm) `��_5 3/4" NPT** f WRENCH STYLE 40 2-7/8"(73,0 mm)DIA. —.– FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT, STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* r17'}"r'r'S'`t __ Assembly 4 - Bulb ' 7/16" 2-1/4" ,3� (11,1 mm) (57,2 mm) d4_ +4 2 NOMINAL } — MAKE-IN I *Temperature rating is III I I I 2-3/16" I 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) . '=��5 ** Pipe thread connections r,`I� " 6* per ISO 7-1 can be 6 provided on special 1/2" NPT** f WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE TFP151 Page 4 of 8 BULB SPRINKLER FINISH(8) K SPRINKLER TEMPERATURE LIQUID TYPE RATING COLOR NATURAL CHROME POLYESTER*** LEAD WAX WAX-OVER-LEAD BRASS PLATED COATED COATED COATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red 2 8 (TY1151) and 175°F(79°C) Yellow 1,2,3 NPT PENDENT 200°F(93°C) Green N/A (TY1251) Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (T and 1) 175°F(79°C) Yellow 1,2,3,5 1,2,3,5 PENDENT 1,2,3,4,5,6,7 1,2,3,5 (TY3251) 200°F(93°C) Green — Figure 2 286°F(141°C) Blue 5.6 1/2" 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 1,2,3,4,5 (TY3251)* 175°F(79°C) Yellow N/A Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (T and 1) 1,2,3,5 1,2,5 175°F(79°C) Yellow PENDENT 1,2,3,4,5,6,7 1,2,5 PEN (ENDEN) 200°F(93°C) Green Figure 3 286°F(141°C) Blue 8.0 3/4" 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 1,2,3,4,5 (TY4251)* 175°F(79°C) Yellow N/A Figure 6 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red 8.0 (T and 1) 175°F(79°C) Yellow 1/2 PENDENT (93°C) 1,2,3,4,5,6 N/A NPT (TY4951) 200°F 93°C) Green Figure 4 286°F(141°C) Blue 360°F(182°C) Mauve Notes: 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) 3. Approved by FM Global(FM Approvals) 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) 5. Approved by the City of New York under MEA 354-01-E 6. VdS Approved(For details contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion- Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2"NPT)or Style 40(3/4-NPT)3/4-Total Adjustment Recessed Escutcheon,as applicable ** 150°F(66°C)maximum ceiling temperature ***Frame and deflector only N/A-Not Applicable TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME LEAD WAX WAX-OVER-LEAD BRASS PLATED POLYESTER* COATED COATED COATED 2.8 UPRIGHT(TY1151) 1/2" and 175 psi(12,1 bar) N/A NPT PENDENT(TY1251) UPRIGHT(TY3151) and 5.6 PENDENT(TY3251) 250 psi(17,2 bar)(a) 1/2" OR NPT 175 psi(12,1 bar) RECESSED PENDENT (TY3251) UPRIGHT(TY4151) and 175 psi(12,1 bar) 8.0 PENDENT(TY4251) 3/4" NPT RECESSED PENDENT 175 psi(12,1 bar) N/A (TY4251) 8.0 UPRIGHT(TY4851) 1/2" and 175 psi(12,1 bar) NPT PENDENT(TY4951) Notes: a. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL),the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL),and the Approval by the City of New York. Frame and deflector only N/A—Not Applicable TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Physical Characteristics Design Frame Bronze Data Button Brass/Copper Criteria Sealing Assembly Beryllium Nickel Approvals w/TEFLON TYCO Series TY-B, 2.8, 5.6, and UL and C-UL Listed Bulb Glass 8.0 K-factor, Upright and Pendent FM Approved Compression Screw Bronze Sprinklers are intended for fire protec- LPCB Approved Deflector Copper tion systems designed in accordance VdS Approved Bushing(K=2.8) Bronze with the standard installation rules NYC Approved recognized by the applicable Listing (Refer to Table A for complete ap- Operation or Approval agency(e.g., UL Listing is proval information, including corro based on the requirements of NFPA sion-resis-tant status.) The glass bulb contains a fluid which 13, and FM Approval is based on the expands when exposed to heat.When requirements of the FM Global Loss Maximum Working Pressure the rated temperature is reached, the Prevention Data Sheets).Only the Style Refer to Table B. fluid expands sufficiently to shatter the 10 or 40 Recessed Escutcheon, as Discharge Coefficient glass bulb, allowing the sprinkler to applicable, is to be used for recessed K=2.8 gpm/psi1/2 (40,3 Ipm/bar1/2) activate and water to flow. pendent installations. K=5.6 gpm/psil/2 (80,6'pm/bail/2) K=8.0 gpm/psi112 (115,2 Ipm/bars/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black,Chrome Plated,or Natural Brass TFP151 Page 6 of 8 2-7/8"DIA. _ G- 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4" (6,4 mm) W RECESS FACE OF (57,2 mm) MOUNTING (END"A" USED FOR SPRINKLER PLATE / RENCH 1/2" NPT MODELS) FITTING / 1/8" (3,2 mm) WRENCH RECESS ��� (END "B" USED FOR j �, % j 3/4" NPT MODELS) ∎ � FIGURE 7 \ `,1 W-TYPE 6 MOUNTING SPRINKLER WRENCH SURFACE - CLOSURE SERIES 1-1/4"(31,8 mm) WRENCH TY-B 3/4" (19,1 mm) RECESS FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY �,1 WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT •I t STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. y �' 5/811/4" (73,0 mm) 3/4" (19,1 mm) 1......• (15,9±6,4 mm) 2-1/4"DIA. 1/4" (6,4 mm) PUSH WRENCH FACE OF (57,2 mm) MOUNTING IN TO ENSURE ENGAGEMENT SPRINKLER PLATE WITH SPRINKLER FITTING WRENCHING AREA 1/8" / (3,2 mm) FIGURE 8 W-TYPE 7 RECESSED T ill SPRINKLER WRENCH —\ � � Installation MOUNTING �■ I TYCO Series TY-B, 2.8, 5.6, and 8.0 SURFACE - -- K-factor, Upright and Pendent Sprin- CLOSURE SERIES 1-5/16" (33,3 mm) klers must be installed in accordance TY-B 13/16" (20,6 mm) with this section. FIGURE 6 General Instructions SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY Do not install any bulb type sprinkler if WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT the bulb is cracked or there is a loss of STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT liquid from the bulb.With the sprinkler - - held horizontally, a small air bubble should be present.The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-Ibs.(13,4 to 26,8 Nm).Higher levels of torque may distort - the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. TFP151 Page 7 of 8 Upright and Pendent Sprinklers Recessed Pendent Sprinklers Care must be exercised to avoid dam- . The Series TY-B Upright and Pendent The Series TY-B Recessed Pendent age to the sprinklers before,during,and Sprinklers must be installed in accor- Sprinklers must be installed in accor- after installation. Sprinklers damaged dance with the following instructions: dance with the following instructions: by dropping, striking, wrench twist/ Note: Install pendent sprinklers in the Step A. After installing the Style 10 slippage,or the like, must be replaced. pendent position;install upright sprin- or 40 Mounting Plate, as applicable, Also, replace any sprinkler that has a klers in the upright position. over the sprinkler threads and with cracked bulb or that has lost liquid from pipe thread sealant applied to the pipe its bulb. (Refer to Installation Section.) Step 1.With pipe thread sealant applied threads, hand-tighten the sprinkler into The owner is responsible for the inspec- to the pipe threads, hand tighten the the sprinkler fitting. tion, testing, and maintenance of their sprinkler into the sprinkler fitting. fire protection system and devices in Step 2. Tighten the sprinkler into the Step B. Tighten the sprinkler into the compliance with this document, as sprinkler fitting using only the W-Type 7pRecessed fitting Wry (Fiyupe well as with the applicable standards 6 Sprinkler Wrench (Figure 7). For 8) With reference to Figure 3 or 4,the of the National Fire Protection Asso- wax-coated sprinklers, use an 8 or 10 W-Type 7 Recessed Sprinkler Wrench ciation (e.g., NFPA 25), in addition to inch adjustable wrench.With reference the standards of any other authorities to Figures 1 through 4, the W-Type is to be applied to the sprinkler wrench having jurisdiction.Contact the installing 7 Recessed Sprinkler Wrench or an flats. contractor or product manufacturer with adjustable wrench, as applicable, is to Step C.After the ceiling is installed or any questions. be applied to the sprinkler wrench flats. the finish coat is applied, slide on the Automatic sprinklers are recommended Style 10 or 40 Closure over the Series When installing wax-coated sprinklers to be inspected,tested,and maintained with an adjustable wrench, exercise TY-B Sprinkler and push the Closure by a qualified Inspection Service in care to prevent damage to the wax over the Mounting Plate until its flange accordance with local requirements coating on the sprinkler wrench flats contacts the ceiling. and/or national codes. or frame arms and, consequently, exposure of bare metal to the corrosive Care and environment. Open the jaws of the wrench sufficiently wide to pass over Maintenance the wrench flats without damaging the wax coating. Before wrench tightening TYCO Series TY-B, 2.8, 5.6, and 8.0 the sprinkler, adjust the jaws of the K-factor, Upright and Pendent Sprin- wrench to contact only the sprinkler klers must be maintained and serviced wrench flats.After wrench tightening the in accordance with this section. sprinkler, loosen the wrench jaws before Before closing a fire protection system removing the wrench. main control valve for maintenance After installation, inspect the sprinkler work on the fire protection system that wrench flats and frame arms and it controls, obtain permission to shut retouch (repair)the wax coating when- down the affected fire protection system ever the coating has been damaged and from the proper authorities and notify all bare metal is exposed. Retouch the wax personnel who may be affected by this coating on the wrench flats by gently action. applying a heated 1/8 inch diameter The owner must assure that the steel rod to the damaged areas of wax, sprinklers are not used for hanging to smooth it back over areas where bare any objects and that the sprinklers are metal is exposed. only cleaned by means of gently dust- ing with a feather duster; otherwise, NOTICE non-operation in the event of a fire or Only retouching of the wax coating inadvertent operation may result. applied to the wrench flats and frame Absence of an escutcheon, which is arms is permitted,and the retouching is used to cover a clearance, may delay to be performed only at the time of the the time to sprinkler operation in a fire initial sprinkler installation. situation. The steel rod should be heated only Sprinklers which are found to be leaking to the point at which it can begin to or exhibiting visible signs of corrosion melt the wax, and appropriate precau- must be replaced. tions need to be taken when handling the heated rod in order to prevent the Automatic sprinklers must never be installer from being burned. painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. TFP151 Page 8 of 8 P/N 57 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE RATING FINISH 530 2.8K UPRIGHT(1/2"NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2"NPT) TY1251 3 PURE WHITE(RAL9010)` 155 155°F(68°C) POLYESTER 570 5.6K UPRIGHT(1/2"NPT) TY3151 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 571 5.6K PENDENT(1/2"NPT) TY3251 5 JET BLACK(RAL9005)" 200 200°F(93°C) POLYESTER 590 8.OK UPRIGHT(3/4"NPT) TY4151 6 WAX COATED 286 286°F(141°C) 286°F(141°C)MAX 591 8.0K PENDENT(3/4"NPT) TY4251 7 LEAD COATED 360 360°F(182°C) WAX-OVER-LEAD 000 OPEN*** 560 8.0K UPRIGHT(1/2"NPT) TY4851 8 286°F(141°C)MAX 561 8.0K PENDENT(1/2"NPT) TY4951 9 CHROME PLATED Notes: Eastern Hemisphere sales only " Available in only 8.0K,155°F(68°C)or 200°F(93°C); requires lead time to manufacture "'Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ("OPEN" indicates sprinkler assembly without glass bulb, button,and sealing assembly) TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Wax Sticks Ordering (for retouching wrench-damaged Warranty Procedure wax coating) Y Specify: (specify color, below)Colored For warranty terms and conditions,visit Contact your local distributor for Coded Wax Stick for retouching(specify www.tyco-fire.com. availability. When placing an order, temperature rating)temperature-rated indicate the full product name and Part Series TY-B Sprinklers, P/N(specify) Number(P/N). Black for 135°F(57°C) P/N 56-065-1-135 Red for 155°F(68°C) P/N 56-065-1-155 Sprinkler Assemblies with Yellow for 175°F(79°C) P/N 56-065-1-175 Blue for 200°F(93°C) NPT Thread Connections and 286°F(141°C) P/N 56-065-1-286 Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright Note: Each wax stick is suitable for or Pendent) Sprinkler with (specify) retouching up to 25 sprinklers. temperature rating, (specify) finish or coating, P/N(Refer to Table C) Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F(93°C) Recessed Escutcheon sprinklers,and,therefore,the286°F(141°C) Specify: Style (10 or 40) Recessed sprinkler is limited to the same maximum Escutcheon with (specify)finish, P/N* ceiling temperature as the 200°F(93°C) *Refer to Technical Data Sheet TFP770 sprinkler(i.e., 150°F 166°C1). Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. TEFLON is trademark of the DuPont Corporation. -NCO _ ti,co Worldwide Fire Protection Contacts www.tyco-fire.com Products Series DS-1 - 5.6 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General The owner is responsible for main- taining their fire protection system A., OW Description and devices in proper operating con- Q p dition. Contact the installing contrac- tor or product manufacturer with any Upright,and Horizontal Sidewall,Stan- questions. dard Response (5 mm bulb), Standard Series DS-1 Dry-type Sprinklers must [` Coverage Dry-type Sprinklers are dec- only be installed in fittings that meet orative glass bulb automatic sprinklers the requirements of the Design Crite typically used where: ria section. • pendent sprinklers are required on ,- . '-TM dry pipe systems that are exposed Sprinkler , to freezing temperatures(e.g.,sprin- 1.1; kler drops from unheated portions of Identification -- buildings) Numbers (SINS) • sprinklers and/or a portion of the =, connecting piping may be exposed TY3255- Pendent to freezing temperatures(e.g.,sprin- TY3155-Upright `' kler drops from wet systems into TY3355-Horizontal Sidewall W' freezers, sprinkler sprigs from wet a systems into unheated attics,or hor- izontal piping extensions through a wall to protect unheated areas of a Data building such as loading docks,over- hangs,and building exteriors) Physical Characteristics Approvals Inlet Copper • sprinklers are used on systems that UL and C-UL Listed Plug Copper are seasonably drained to avoid FM Approved Yoke Stainless Steel freezing(e.g.,vacation resort areas) VdS Approved Casing Galvanized Carbon Steel TY3255 w/Standard Escutcheon only Insert Bronze NYC Approved B NOTICE under MEA 352-01-E Bulb Seat Stainless Steel Series DS 1 Dry-type S Sprinklers LPCB Approved Bulb(5 mm dia.) Glass p Reference No.094a/11 Compression Screw Bronze described herein must be installed CE Certified Deflector Bronze and maintained in compliance with this Certificate of Conformity No.0832- Frame Bronze document, as well as with the applica- CPD-2015 Guide Tube Stainless Steel ble standards of the National Fire Pro- (Refer to Tables A and B for details.) Water Tube Stainless Steel tection Association(NFPA), in addition Maximum Working Pressure Spring Stainless Steel to the standards of any other authori- 175 psi(12,1 bar) Sealing Assembly Beryllium Nickel ties having jurisdiction.Failure to do so w/TEFLON may impair the performance of these Inlet Thread Connections Escutcheon Carbon Steel devices. 1 inch NPT ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psiv2(80,6 Ipm/barli2) IMPORTANT Temperature Ratings Always refer to Technical Data Refer to Tables A and B. Sheet TFP700 for the "INSTALLER Finishes WARNING" that provides cautions Sprinkler:Refer to Table D. - with respect to handling and instal- Escutcheon: Refer to Table D. lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 JANUARY 2015 TFP500 TFP500 Page 2 of 10 SPRINKLER ESCUTCHEON TEMPERATURE BULB SPRINKLER FINISH TYPE TYPE RATING COLOR CODE NATURAL CHROME POLYESTER* BRASS PLATED 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow 1,2,3,4,5,6 1,2,4,5,6 STANDARD 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3,6 1,2,6 135°F(57°C) Orange 155°F(68°C) Red 1,2,3,5 1,2,5 175°F(79°C) Yellow RECESSED 200°F(93°C) Green 286°F(141°C) Blue 1,2 PENDENT 360°F(182°C) Mauve N/A (TY3255) 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow DEEP 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3,4,5 1,2,4,5 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow WITHOUT 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3 1,2 135°F(57°C) Orange 155°F(68°C) Red UPRIGHT 175°F(79°C) Yellow 1,2,3,4,5 1,2,4,5 (TY3155) WITHOUT 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3 1,2 Notes: 1. Listed by Underwriters Laboratories,Inc.(UL),maximum order length of 48 inches 2. Listed by Underwriters Laboratories for use in Canada(C-UL),maximum order length of 48 inches 3. Approved by FM Global(FM Approvals),maximum order length of 48 inches 4. Loss Prevention Certification Board(LPCB)and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E 6. Approved by VdS • Frame and deflector only N/A-Not Applicable TABLE A SERIES DS-1 PENDENT& UPRIGHT DRY-TYPE SPRINKLERS,5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER FINISH ' SPRINKLER ESCUTCHEON TEMPERATURE BULB TYPE TYPE RATING COLOR CODE NATURAL CHROME POLYESTER*** BRASS PLATED 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow STANDARD 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 135°F(57°C) Orange 155°F(68°C) Red HSW* 175°F(79°C) Yellow 1°° 2°° 3»»' 4,5 1",2°°,4,5 (TY3355) DEEP 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 135°F(57°C) Orange - 155°F(68°C) Red 175°F(79°C) Yellow WITHOUT 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve Notes: 1. Listed by Underwriters Laboratories,Inc.(UL),maximum order length of 48 inches 2. Listed by Underwriters Laboratories for use in Canada(C-UL),maximum order length of 48 inches 3. Approved by FM Global(FM Approvals),maximum order length of 48 inches 4. Loss Prevention Certification Board(LPCB)and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E • Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches(100 to 300 mm) •• Light and ordinary hazard occupancies only •*• Light hazard occupancies only ••••Frame and deflector only TABLE B SERIES DS-1 HORIZONTAL SIDEWALL(HSW)DRY-TYPE SPRINKLER, 5.6K,STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS PLUG WITH C• O INLET SEALING r Y ASSEMBLY F f YOKE WRENCH r SPRING �� RECESS ,1� lk/ 4 INLET 1��1 BAND 1e.- ir 1 of WATER 1 1 WRENCH �1„ TUBE k i t CASING FLAT , - O 1 TUIBE ;I INSERT PUSH WRENCH 1 ; INTO ENSURE ENGAGEMENT $ l � BULB WITH SPRINKLER FRAME ! 6 01 SEAT WRENCHING AREA IlkIlk. FIGURE 2 . 5 mm BULB W-TYPE 7 VENT HOLE III 1p, WRENCH COMPRESSION DEFLECTOR .y SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER,5.6K, STANDARD RESPONSE ASSEMBLY TFP500 Page 4 of 10 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN CRITERIA SECTION) CRITERIA SECTION) CRITERIA SECTION) FACE OF FACE OF FACE OF SPRINKLER SPRINKLER SPRINKLER FITTING FITTING FITTING \ \ ' I I I ORDER LENGTHS: ORDER LENGTHS: ORDER LENGTHS: 3-1/2" DIA. 2-3/4"to 48" 1-3/4"DIA. 3-3/4"to 48" 1/2"to 46" x(88,9 mm) (69,9 to 1219,2 mm) ,5 mm 44 (95,3 to 1219,2 mm) (12,7 to 1168,4 mm) ( mm) 2-1/2"DIA. IN 1/4" (6,4 mm) -_ IN 1/4"(6,4 mm) 2-1/4"DIA. IN 1/4"(6,4 mm) (63,5 mm) INCREMENTS INCREMENTS (57,2 mm) INCREMENTS i_ -_I �jI �� , FACE OF ! ! . M!% FACE OF CEILING FACE OF' CEILING Tit f I /�i I% CEILING I lir Ik 0 1 � � 4-1/4"t 1/8"Ili - III 1 (108,0±3,2 mm) 2-3/16" ±1/8" 3"DIA. 1-3/8"It 1/8" 2-7/8"DIA. I rig' (55,6±3,2 mm) _(76,2 mm) (34,9±3,2 mm) (73,0 mm) 11 �:� FIGURE 4 FIGURE 3 PENDENT(TY3255) FIGURE 5 PENDENT(TY3255) WITH STANDARD PENDENT(TY3255) WITH STANDARD ESCUTCHEON RECESSED ESCUTCHEON WITH DEEP ESCUTCHEON SPRINKLER FITTING / (REFER TO DESIGN TOP OF CRITERIA SECTION) DEFLECTOR FACE OF SPRINKLER FITTING - \ ORDER LENGTHS: 1 5"to48" (127,0 to 1219,2 mm) ORDER LENGTHS: IN 1/4" (6,4 mm) 5"to 48" INCREMENTS (127,0 to 1219,2 mm) IN 1/4"(6,4 mm) INCREMENTS FACE OF I SPRINKLER 1 FITTING MINIMUM ' \ 1-3/4"(44,5 mm) �l DEFLECTOR TO CEILING SPRINKLER FITTING (REFER TO DESIGN } CRITERIA SECTION) FIGURE 6 FIGURE 7 PENDENT(TY3255) UPRIGHT(TY3155) WITHOUT ESCUTCHEON WITHOUT ESCUTCHEON TFP500 Page 5 of 10 ORDER LENGTHS: Operation 2-3/4"to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm)INCREMENTS When TYCO Series DS-1 5.6K Pendent, - _ __ 2-3/8"±3,2 1/8" Upright,and Horizontal Sidewall,Stan (60,3±3,2 mm) dard Response, Standard Coverage FACE OF FACE OF Dry type Sprinklers are in service, — SPRINKLER MOUNTING — water is prevented from entering the FITTING SURFACE \ assembly by the Plug with Sealing Assembly(Ref. Figure 1) in the Inlet of the sprinkler. l I Mill: _e,I 3" DIA. 'II,II�IIIIII�,III (76,2 mm) The glass bulb contains a fluid that expands when exposed to heat.When s--- f7 3.5° the rated temperature is reached, the SPRINKLER FITTING 1-3/4"DIA. fluid expands sufficiently to shatter (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16" the glass bulb, and the Bulb Seat is CRITERIA SECTION) OF WATERWAY (7,9 mm) released. FIGURE 8 The compressed Spring is then able HORIZONTAL SIDEWALL(TY3355) to expand and push the Water Tube as WITH STANDARD ESCUTCHEON well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with ORDER LENGTHS: Sealing Assembly from the Inlet,allow- . 1/2"to 45-3/4"(12,7 to 1162,1 mm) ing the sprinkler to activate and flow IN 1/4" (6,4 mm)INCREMENTS water. 1 _ 4-1/4"± 1/8" 2-1/2"DIA. FACE OF (108,0 t 3,2 mm) Design FACE OF (63,5 mm) MOUNTING SPRINKLER SURFACE Criteria FITTING t TYCO Series DS-1 5.6K Pendent, �■ _ + Upright,and Horizontal Sidewall,Stan- 'IIIIIIIIIIIIII��III 3-1/2" DIA. dard Response, Standard Coverage �_ (88,9 mm) Dry-type Sprinklers are intended for -_L ,,, 3.5° I use in fire sprinkler systems designed SPRINKLER FITTING in accordance with the standard instal- (REFER TO DESIGN \ CENTERLINE 5/16" lation rules recognized by the applica- ble listing or approval agency(e.g., UL Listing is based on NFPA 13 require- FIGURE 9 ments). For more information on LPCB HORIZONTAL SIDEWALL(TY3355) Approval, contact Tyco Fire Suppres- WITH DEEP ESCUTCHEON sion&Building Products at the follow- ing office: ORDER LENGTHS: Kopersteden 1 5-1/2"to 48"(139,7 to 1219,2 mm) 7547 TJ Enschede IN 1/4" (6,4 mm)INCREMENTS MINIMUM The Netherlands 2-1/4"(57,2 mm) Tel: +31-(0)53-428-4444 DEFLECTOR TO Fax: +31-(0)53-428-3377 FACE OF MOUNTING Sprinkler Fittings SPRINKLER SURFACE Install 1 inch NPT Series DS-1 Dry-type FITTING Sprinklers in the 1 inch NPT outlet or 1 run of the following fittings: VI"Il } tee fittings that meet the dimen- `_� 3.5° 5/16" sional requirements of ANSI B16.3 SPRINKLER FITTING (7,9 mm) (Class 150) (REFER TO DESIGN CENTERLINE • cast iron threaded tee fittings that . CRITERIA SECTION) OF WATERWAY meet the dimensional requirements FIGURE 10 of ANSI B16.4(Class 125) HORIZONTAL SIDEWALL(TY3355) Do not install Series DS-1 Dry-type WITHOUT ESCUTCHEON Sprinklers into elbow fittings.The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. TFP5OO Page 6 of 10 Temperatures for Heated Area(1) Drainage - In accordance with the minimum Ambient Temperature 40°F 50°F 60°F requirements of the National Fire Pro- Exposed to (4°C) (10°C) (16°C) tection Association for dry pipe sprin- Discharge End of Sprinkler Minimum Exposed Barrel Length(2), kler systems, branch, cross, and Inches feed-main piping connected to Dry (mm) Sprinklers and subject to freezing tem- peratures must be pitched for proper 40°F 0 0 0 drainage. (4°C) Exposure Length 30°F 0 0 0 When using Dry Sprinklers in wet pipe (-1°C) sprinkler systems to protect areas 20°F a subject to freezing temperatures, use (-7°C) (100) 0 0 Table C to determine a sprinkler's 10°F 8 1 appropriate exposed barrel length to 10° (-12° F (200) (1 0 prevent water from freezing in the con- necting pipes due to conduction. The 0°F 12 3 exposed barrel length measurement (-18°C) (305) (75) 0 must be taken from the face of the -10°F 14 4 1 sprinkler fitting to the surface of the (-23°C) (355) (100) (25) structure or insulation that is exposed to the heated area. Refer to Figure 11 -20°F 14 6 3 for an example. (-29°C) (355) (150) (75) For protected area temperatures -30°F 16 8 4 between those given above, the (-34°C) (405) (200) (100) minimum recommended length from -40°F 18 8 4 the face of the fitting to the outside of (-40°C) (455) (200) (100) the protected area may be determined by interpolating between the indicated -50°F 20 10 6 values. (-46°C) (510) (255) (150) -60°F 20 10 6 Clearance Space (150) In accordance with Section 8.4.9.2 of (-51°C) (510) (255) the 2010 edition of NFPA 13,when con- Notes: necting an area subject to freezing and 1. For protected area temperatures that occur between values listed above,use the next cooler temperature. an area containing a wet pipe sprinkler 2. These lengths are inclusive of wind velocities up to 30 mph(18,6 kph). system, the clearance space around TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS the sprinkler mst be barrel sealed.. dry-type pera- MINIMUM RECOMMENDED LENGTHS tune must be sealed. Due to tern s,the ture differences between two areas,the potential for the formation of conden- You can also install Series DS-1 Dry- For dry pipe system installations, use sation in the sprinkler and subsequent type Sprinklers in the 1 inch NPT outlet only the side outlet of maximum 2-1/2 ice build-up is increased. If this con- of a GRINNELL Figure 730 Mechanical inch reducing tee when locating Series densation is not controlled,ice build-up Tee and GRINNELL G-FIRE Figure 522; DS-1 Dry-type Sprinklers directly can occur that might damage the dry- however,the use of the Figure 730 Tee below the branchline; otherwise, use type sprinkler and/or prevent proper and Figure 522 for this arrangement is the configuration shown in Figure 12 to operation in a fire situation. limited to wet pipe systems. assure complete water drainage from The confi uration shown in Fi ure 13 above Series DS-1 Dry-type Sprin- Use of the Model DSB-2 Dry Sprinkler g 9 klers and the branchline. Failure to do Boot,described in technical data sheet is only applicable for wet pipe systems so may result in pipe freezing and water TFP591 and shown in Figures 14 and where the sprinkler fitting and water- damage. 15,can provide the recommended seal. filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the NOTICE - minimum exposure length depicted in Do not install Series DS-1 Dry-type Figure 11.Refer to the Exposure Length Sprinklers into any other type fitting section. without first consulting the Tyco Fire For wet pipe system installations of 1 Protection Products (TFPP) Technical inch NPT Series DS-1 Dry Type Sprin Services. Failure to use the appropriate klers connected to CPVC piping, use fitting may result in one of the following: only the following TYCO CPVC fittings: • failure of the sprinkler to operate • 1" x 1" NPT Female Adapter (P/N properly due to formation of ice 80145) over the Inlet Plug or binding of the Inlet Plug • 1" x 1" x 1" NPT Sprinkler Head • insufficient engagement of the Adapter Tee(P/N 80249) Inlet pipe-threads with consequent leakage TFP500 Page 7 of 10 RUN FACE OF OUTLET TO WET SIDE • SPRINKLER O _1 PLUGGED SYSTEM OUTLET FITTING 7 f\SPRINKLER PLUGGED TO DRY FITTING HEATED HEATED EXPOSURE SYSTEM (SEE DESIGN AREA AREA LENGTH CRITERIA (SEE DESIGN SECTION) DSB-2 CRITERIA AREA DSB-2 SPRINKLER INTENDED SECTION) SUBJECT DSB-2 INTENDED FITTING FOR FREEZER TO INTENDED FOR FREEZER (SEE DESIGN STRUCTURES FREEZING FOR FREEZER STRUCTURES CRITERIA STRUCTURES SECTION) ili • 7777 T .T � ' T� FIGURE 12 FIGURE 13 FIGURE 11 SPRINKLER FITTING SPRINKLER FITTING EXPOSURE LENGTH UNHEATED AREA HEATED AREA STRAP TIES 1-3/4"DIA. • (ENDS ON (44,5 mm) . OPPOSING CLEARANCE INSULATED SIDES OF HOLE FREEZER BOOT) ADHESIVE STRUCTURE __ DSB-2 BOOT DSB-2 i ..,,k, y IADHESIVE BOOT i�4$ 1-3/4" DIA. 1 r (44,5 mm) I I ,I III CLEARANCE HOLE i� �j INSULATED i,��E FREEZER J-, STRUCTURE STRAP TIES IMM DS-1 (ENDS ON SHOWN WITH FilSHOWN WITH OPPOSING SO STANDARD STANDARD SIDES OF ESCUTCHEON ESCUTCHEON BOOT) FIGURE 14 FIGURE 15 MODEL DSB-2 DRY SPRINKLER MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER DS-1 DRY-TYPE SPRINKLER TFP5OO Page 8 of 10 Installation Note: If sprinkler removal becomes have not operated,should be replaced necessary, remove the sprinkler using if they cannot be completely cleaned TYCO Series DS-1 5.6K Pendent, the same wrenching method noted by wiping the sprinkler with a cloth or Upright,and Horizontal Sidewall,Stan- above.Sprinkler removal is easier when by brushing it with a soft bristle brush. a non-hardening sealant was used dard Response, Standard Coverage Care must be exercised to avoid Dry-type Sprinklers must be installed and torque guidelines were followed. damage to the sprinklers before, in accordance with this section. After removal, inspect the sprinkler for during, and after installation. Sprin- damage. klers damaged by dropping, striking, General Instructions Step 3. After installing the ceiling or wrench twist/slippage,or the like,must Series DS-1 Dry-type Sprinklers must wall and applying a ceiling finish, slide be replaced. Also, replace any sprin- only be installed in fittings that meet on the outer piece of the escutch- kler that has a cracked bulb or that has the requirements of the Design Crite eon until it comes in contact with the lost liquid from its bulb (Ref. Installa- riasection. Refer to the Design Criteria ceiling/wall. Do not lift the ceiling panel tion section). section for other important require- out of its normal position. ments regarding piping design and The owner is responsible for the sealing of the clearance space around When using the Deep Escutcheon, inspection,testing,and maintenance of the Sprinkler Casing. hold the outer piece in contact with the their fire protection system and devices Do not install mounting surface(ceiling or wall).Then in compliance with this document, as D t all any bulb-type sprinkler if the bulb cracked lb there is a loss rotate the inner piece approximately 1/4 well as with the applicable standards turn with respect to the outer piece, of the National Fire Protection Asso- of liquid held d horizontally,the bulb. Witlly,a small h the sprin-air bubble to hold the Deep Escutcheon firmly ciation (e.g., NFPA 25), in addition to should be present.The diameter of the together. the standards of any other authorities air bubble is approximately 1/16 inch having jurisdiction.Contact the install (1,6 mm) for the 135°F (57°C) rating to Care and ing contractor or product manufacturer 1/8 inch(3,2 mm)for the 360°F(182°C) with any questions. rating. Maintenance Automatic sprinkler systems are rec- ommended a leak-tight 1 inch NPT sprinkler TYCO Series DS-1 5.6K Pendent, nd maintained to be inspected,qualiied tested, joint by applying a minimum-to-maxi- Upright, and Horizontal Sidewall, and Service in c a qualified with mum torque of 20 to 30 lbs.-ft.(26,8 to tion Service in accordance with local q ( Standard Response, Standard Cover- requirements and/or national codes. 40,2 Nm). Higher levels of torque may age Dry-type Sprinklers must be main- distort the sprinkler Inlet with conse- tained and serviced in accordance with quent leakage or impairment of the this section. sprinkler. Before closing a fire protection system Do not attempt to compensate for main control valve for maintenance insufficient adjustment in an Escutch- work on the fire protection system eon Plate by under or over-tightening that it controls, obtain permission to the Sprinkler. Re-adjust the position of shut down the affected fire protection the sprinkler fitting to suit. systems from the proper authorities Notes: and notify all personnel who may be • Install pendent sprinklers only in affected by this action. the pendent position; install upright Absence of the outer piece of an sprinklers only in the upright posi- escutcheon, which is used to cover a tion. The deflector of a pendent or clearance hole, may delay the time to upright sprinkler is to be parallel to sprinkler operation in a fire situation. the ceiling. A Vent Hole is provided in the Bulb • Install horizontal sidewall sprinklers Seat(Ref.Figure 1)to indicate if the Dry in the horizontal position with their Sprinkler is remaining dry. Evidence of centerline of waterway perpendicu- leakage from the Vent Hole indicates lar to the back wall and parallel to potential leakage past the Inlet seal • the ceiling. Ensure the word "TOP" and the need to remove the sprinkler on the Deflector faces the ceiling. to determine the cause of leakage; Step 1. With a non-hardening pipe- for example, an improper installation thread sealant such as TEFLON applied or an ice plug. Close the fire protec- to the inlet threads, hand-tighten the tion system control valve and drain the sprinkler into the sprinkler fitting. system before removing the sprinkler. Step 2. Wrench-tighten the sprinkler Sprinklers which are found to be using either: leaking or exhibiting visible signs of • a pipe wrench on the Inlet Band or corrosion must be replaced. the Casing (Ref. Figure 1) Automatic sprinklers must never be • the W-Type 7 Sprinkler Wrench on painted, plated, coated, or other- the Wrench Flat(Ref. Figure 2) wise altered after leaving the factory. Modified sprinklers must be replaced. Apply the wrench recess of the W-Type Sprinklers that have been exposed to 7 Sprinkler Wrench to the wrench flat. corrosive products of combustion,but TFP500 Page 9 of 10 - P/N* 60 - XXX - X - XXX I I SIN SPRINKLER ESCUTCHEON FINISH FINISHII) Pendent with TY3255 SIGNAL WHITE 96 Standard Escutcheon(1"NPT) (Figure 3) 0 PLATED (RAL9003) POLYESTER 93 Pendent with TY3255 Deep Escutcheon(1"NPT) (Figure 5) NATURAL SIGNAL WHITE 97 Pendent with TY3255 1 BRASS (RAL9003)OLYESTE Recessed Escutcheon(1"NPT) (Figure 4) Pendent without TY3255 NATURAL BRASS 92 Escutcheon(1"NPT) (Figure 6) 2 BRASS PLATED Sidewall with TY3355 SIGNAL WHITE SIGNAL WHITE 94 Standard Escutcheon(1" NPT) (Figure 8) 4 (RAL9003) (RAL9003)OYESTE 53 Sidewall with TY3355 CHROME CHROME Deep Escutcheon(1"NPT) (Figure 9) 9 PLATED PLATED 54 Sidewall without TY3355 Escutcheon(1"NPT) (Figure 10) I TEMPERATURE ORDER RATING(2) LENGTH(3) 98 Upright without TY3155 Escutcheon(1"NPT) (Figure 7) 0 135°F(57°C) 055 5.50" Notes: 1 155°F(68°C) 082 8.25" 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 2. 360°F(182°C)temperature rating applies to non-recessed sprinkler assemblies. 2 175°F(79°C) 180 18.00" 3. Dry-type Sprinklers are furnished based upon"Order Length"as mea- sured per Figures 3 through 10,as applicable,and for each individual 3 200°F(93°C) 187 18.75" sprinkler where it is to be installed.After the measurement is taken, round it to the nearest 1/4 inch increment. • Use Prefix"I"for ISO 7-R 1 Connection(e.g.,1-60-961-1-180). 4 286°F(141°C) 372 37.25" 5 360°F(182°C) 480 48.00" TABLE D SERIES DS-1 DRY-TYPE SPRINKLERS,5.6K, STANDARD RESPONSE PART NUMBER SELECTION Limited • SIN: • P/N from Table D TY3255—Pendent Part numbers are for 1 inch NPT Warrant TY3155— Upright standard order sprinklers. Orders Y TY3355—Horizontal Sidewall for all other sprinkler assemblies For warranty terms and conditions,visit • Order Length: must be accompanied by a complete www.tyco-fire.com. Dry-type Sprinklers are furnished description. • based upon Order Length as mea- Sprinkler Wrench Ordering sured per Figures 3 through 10, as Specify W-Type 7 Sprinkler Wrench, applicable.After the measurement is P/N 56-850-4-001 Procedure taken,round it to the nearest 1/4 inch Sprinkler Boot increment. Specify Model DSB-2 Dry Sprinkler Contact your local distributor for avail- • Inlet Connections: Boot, P/N 63-000-0-002 ability. When placing an order, indi- 1 Inch NPT cate the full product name, including (Standard) This part number includes one(1)Boot, . description and part number(P/N). two(2)Strap Ties,and 1/3 oz.of Adhe- ISO 7-R 1 sive (a sufficient quantity for installing Dry-type Sprinklers (For information on ISO Inlet Thread one boot). When ordering Series DS-1 5.6K Connections, contact your Tyco Pendent, Upright,and Horizontal Side- Sales Representative.) wall, Standard Response, Standard Coverage Dry-type Sprinklers,specify • Temperature Rating the following information: • Sprinkler Finish • Escutcheon Type and Finish, as applicable TFP500 Page 10 of 10 GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. t TEFLON is trademark of the DuPont Corporation. �'/ . ,. Schedule 10 and Schedule 40 _ . FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. . other fine pipe products. Schedule 10 Pipe Nominal Pipe Size O.D. I.D. Nom. Wall Weight/Ft Bundle (in) (in) (in) (in) Size 1 1 .315 1.097 0.109 1 .40 lbs/ft 61 1-1/4 1.660 1.442 0.109 1 .81 lbs/ft 37 1-1/2 1.900 1.682 0.109 2.08 lbs/ft 37 2 2.375 2.157 0.109 2.64 lbs/ft 37 2-1/2 2.875 2.635 0.120 3.53 lbs/ft 37 3 3.500 3.260 0.120 4.33 lbs/ft 24 4 4.500 4.260 0.120 5.62 lbs/ft _ 19 Schedule 40 Pipe Nominal Pipe Size O.D. I.D. Nom. Wall Weight/Ft Bundle (in) (in) (in) (in) Size 1 1.315 1.049 0.133 1.68 lbs/ft 61 1-1/4 1.660 1.380 0.140 2.27 lbs/ft 37 - 1-1/2 1.900 1.610 0.145 2.72 lbs/ft 37 2 2.375 2.067 0.154 3.65 lbs/ft 37 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's . instructions for the specific fitting used. • 1819 Clarkson Road For additional information, U iik Nom"/) Chesterfield, MO 63017 contact your salesperson today at C I us , n i)o BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED FAX:(636)537-2645 in the USA, from Canada \N-ww.bullmoosetube.com call(800)882 2-4666 41> AL Am company e-mail:into(n bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. Eddy Flow The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems for roll grooving and welding. Please check with in commercial and residential construction, Bull appropriate sources for up-to-date listings and Moose Tube has added Eddy Flow to its approval information. comprehensive line of sprinkler pipe products. As an added benefit, it is more economical to use than Eddy Flow is a specially engineered replacement for schedule 10 due to reduced delivery costs and ease schedule 10, offering better flow characteristics while of handling. Furthermore, Eddy Flow's larger ID providing design flexibility. This product is FM provides an opportunity for downsizing and further approved, as well as UL listed (for U.S. and Canada) cost savings. COMPARISON Inside Diameter C.R.R.* NPS O.D. Eddy Flow Sch. 10 Sch. 40 Eddy Flow Schedule 40 (in) (in) (in) (in) (in) 1-1/4 1.660 1.515 1.442 1.380 2.93 1.00 1-1/2 1.900 1.734 1.682 1.610 3.44 1.00 2 2.375 2.209 2.157 2.067 2.78 1.00 2-1/2 2.875 2.729 2.635 2.469 1.09 1.00 3 3.500 3.342 3.260 3.068 1.00 1.00 4 4.500 _ 4.316 4.260 4.026 1.00 1.00 * Corrosion Resistance Ratio BENEFITS Dual Certified to ASTM A135 and A795. ? FM approved for roll grooving and welding for use in wet systems. ? UL listed(for U.S.and Canada)for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction,and deluge type sprinkler systems. '? Lightweight-saves shipping costs,and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 175 psi. ? Floor stock available in various lengths produced in Trenton(GA), Gerald(MO),and Masury(OH).Also can be ordered in custom lengths. ' Can be supplied roll grooved,or plain end for use with Victaulic"Flt Fittings. Can be used for wet and dry*systems. *Eddy Flow can be hot dipped galvanized to meet FM's requirement for dry systems. PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be • free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road Chesterfield, For additional information, C turn us ,A field,MO 63017 contact your salesperson today at a■ M009E TUBE CO�I�ANy (800)325-4467 (800)325 4467 or(636)537-2600 FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41> A(CAPRPQcompany e-mail:in fo@.bullmoosetube.corn *rrwovec All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product spedfications without notice and without incurring obligation. Eddyth read 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1 .0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS x3 Ip I 5; i t«. =9 i^ r,sue, 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, U Chesterfield,MO 63017 contact your salesperson today at c L US `(qk (� BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED _. j � V FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 11:* A LPR O company e-mail:salesnbullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 SMITH-COOPER' INTERNATIONAL CORPORATE OFFICE TEL(800) 766-0076 LOCAL (323) 890-4455 FAX(323) 890-4456 WWW.SMITHCOOPER.COM -- - -a 0 ., . -,.. • . . • .. '.c., , lb • , A oak „ .-.•, ,,: , .A .------ _ -- tilt '4100 / '' , .,. I il Is 1 i 0 a :','■ . , ',..........e is . ,:. . . . ..f • .,,,. . .... sir , ., . , o\fr, _ _ ., _...... Grooved Col pl* igs & Fit ii gs SMITHCOOPER® I N T E R N A T I O N A L GROOVED COUPLINGS & FITTINGS TABLE OF CONTENTS Lightweight Couplings 1-2 Concentric Reducers & Reducing Tees 10 Standard Weight Couplings 3-4 Threaded Mechanical Tees 11-12 Reducing Couplings 5 Grooved Mechanical Tees 13 Hinged Flange Adapters 6 Strap Tees 14 Short Radius Fittings 7 Adapter Elbow 15 Drain Cap 7 COUPLET®Adapter Nipples. 16 • Drain Elbow 7 Standard Roll Groove Specifications 17 Standard Radius Elbows 8 Standard Cut Groove Specifications 18 Tee 9 UL Listed/FM Approved Sprinkler Pipe Cross 9 and Warranty Information 19 Caps 9 Installation Instructions 20 Grooved x Flange Adapter 9 Housing • Ductile Iron Conforming to ASTM A536 Coating •Orange Paint • Hot Dipped Galvanized Conforming to ASTM A153 Hardware • Electroplated Track Bolts Conforming to ASTM A183 with a minimum tensile strength of 110,000 psi • 100%Magnetic Particle Inspection of Each Bolt • Gaskets •Grade E EPDM(Green Stripe) Temperature Range:—30°F(-34°C)to+230°F(+110°C) • Grade T Nitrile (Orange Stripe) Temperature Range:—20°F(-29°C)to+180°F(+82°C) Grooves • Dimensions to AWWA C606 All COOPLOKTM Grooved products c us UL Listed and FM Approved. LISTED APPROVED SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smithcooper.com (1( _: .:) 500 Series Lightweight Flexible Couplings NI /I ...7 IT cOus jrtIVE ri, IIIIII Ili .... l'illirl . , APP® 11111 _ = ,1 - Fig. 65LF& 66LF-Lightweight Flexible Couplings C B Part Number Max Pipe Max Working Dimensions Pipe Size Pipe OD End Gap Pressure A B C Bolt Size Deflection Weight Painted Galy IN/mm IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm Degrees LB/kg 1-1/4 1.66 1/8 500 2.58 4.09 1.85 3/8" x 2 1.2 85113012 66113012 2.1° 32 42.2 3.2 34.5 65.5 103.9 47.0 M10 x 52 0.5 1-1/2 1.900 1/8 500 2.85 4.37 1.85 3/8" x 2 1.3 65113014 66113014 1.9' 40 48.3 3.2 34.5 72.4 111.0 47.0 M10 x 52 0.6 2 2.375 1/8 500 3.37 4.8 1.85 3/8" x 2-1/2 1.7 65113020 66113020 2.0° 50 60.3 3.2 34.5 85.6 121.9 47.0 M10 x 60 0.8 2-1/2 2.875 1/8 500 3.88 5.28 1.85 3/8" x 2-1/2 1.9 65113024 66113024 2.3° 65 73.0 3.2 34.5 98.6 134.1 47.0 M10 x 65 0.9 3 3.500 1/8 500 4.4 5.91 1.85 3/8" x 2-1/2 2.1 65113030 66113030 2.0° 80 88.9 3.2 34.5 111.8 150.1 47.0 M10 x 65 0.9 4 4.500 1/4 500 5.75 7.44 2.01 1/2" x 3-1/4 3.6 65113040 66113040 2.2° 100 114.3 6.4 34.5 146.1 189.0 51.1 M12 x 80 1.6 5 5.563 1/4 500 6.79 9.13 2.01 5/8" x 3-3/4 5.1 65LF3050 66113050 1.8° 125 141.3 6.4 34.5 172.5 231.9 51.1 M16 X 95 2.3 6 6.625 1/4 500 7.95 10.31 2.01 5/8" x 3-3/4 6.0 65113060 66113060 1.6° 150 168.3 6.4 34.5 201.9 261.9 51.1 M16 X 95 2.7 8 8.625 1/4 500 10.8 13.07 2.52 3/4" X 5-1/4 10.6 65113080 66113080 1.4° 200 219.1 6.4 34.5 274.3 332.0 64.0 M19 X 110 4.8 NOTES: 1. All bolts and gaskets identified by SCI logo. 2. 100%Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. • 4. Gasket Grade E EPDM(green stripe): • Temperature range: -30°F(-34°C) to+230°F(+110°C). 5. Gasket Grade T Nitrile(orange stripe): • Temperature range: -20°F(-29°C) to+180°F(+82°C). 6. See Installation Instructions on Page 20. 7. SMITH-COOPER Warranty(see page 19) only applies to assemblies made up using gaskets, housings, and bolts with the 4e. logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 1 - z. (i t -1.ok 500 Series Lightweight Rigid Couplings (` )t'1i , ILS, , 7 ---- 1111N f. /.• . .!**, N , •{ APPROVED r b.„,1 IF, ,..,.. t■ ■ xa r C Fig. 65LR & 66LR-Lightweight Rigid Couplings Part Number Max Pipe Max Working Dimensions Pipe Size Pipe OD End Gap Pressure A B C Bolt Size Weight Painted Galv i IN/mm IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm LB/kg - 1-1/4 1.660 1/8 500 2.66 4.09 1.85 3/8" x 2 1.2 65113012 66113012 32 42.2 3.2 34.5 67.6 103.9 47.0 M10 x 52 0.5 1-1/2 1.900 1/8 500 2.93 4.37 1.85 3/8" x 2 1.3 65113014 661/3014 40 48.3 3.2 34.5 74.4 111.0 47.0 M10 x 52 0.6 2 2.375 1/8 500 3.44 4.8 1.85 3/8" x 2-1/2 1.7 65113020 66113020 50 60.3 3.2 34.5 87.4 121.9 47.0 M10 x 60 0.8 2-1/2 2.875 1/8 500 3.96 5.28 1.85 3/8" x 2-3/4 1.9 651R3024 66113024 65 73.0 3.2 34.5 100.6 134.1 47.0 M10 x 65 0.9 3 3.500 1/8 500 4.55 5.91 1.85 3/8" x 2-3/4 2.1 65113030 66113030 80 88.9 3.2 34.5 115.6 150.1 47.0 M10 x 65 1.0 4 4.500 1/4 500 5.83 7.28 2.01 3/8" x 2-3/4 3.6 65113040 66113040 100 114.3 6.4 34.5 148.1 184.9 51.1 M10 x 65 1.6 5 5.563 1/4 500 6.87 8.62 2.01 1/2"x 3-3/4 5.1 65113050 66113050 125 141.3 6.4 34.5 174.5 218.9 51.1 M12 x 95 2.3 6 6.625 1/4 500 8.03 9.76 2.01 1/2" x 3-1/4 6.0 65113060 66113060 150 168.3 6.4 34.5 204.0 247.9 51.1 M12 x 95 2.7 8 8.625 1/4 500 10.16 12.52 2.52 5/8" x 4-1/2 10.6 65113080 66113080 200 219.1 6.4 34.5 258.1 318.0 64.0 M16 x 120 4.8 NOTES: 1. All bolts and gaskets identified by SCI logo. - 2. 100%Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): •Temperature range: -30°F(-34°C) to+230°F(+110°C). _ 5. Gasket Grade T Nitrite (orange stripe): • Temperature range: -20°F(-29°C) to+180°F(+82°C). 6. See Installation Instructions on Page 20. 7. SMITH-COOPER Warranty(see page 19) only applies to assemblies made up using gaskets, housings, and bolts with the ® logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Avmoveo A c'( II! . _ 500 Series Reducing Couplings B . Pt / cOus 1 ../ .. ,a,. --� Iflui1I it pi.r p I.E. i ,. _. w,._, , r Fig. 65RC & 66RC-Reducing Couplings Part Number Max Pipe Max Working Dimensions Pipe Size End Gap Pressure A B C Bolt Size Deflection Weight . Painted _ Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm Degrees LB/kg 2 x 1-1/2 1/8 300 3.43 4.88 1.85 3/8 x 2-1/4 1.9 65RC3020014 66RC3020014 2.00 50 x 40 3.2 20.7 87.1 124.0 47.0 M10 x 57 0.9 2-1/2 x 2 1/8 300 3.98 5.35 1.85 3/8x2-l/2 2.3 65RC3024020 66RC3024020 1.5° 65 x 50 3.2 20.7 101.1 135.9 47.0 M10 x 64 1.0 3 x 2 1/8 300 4.59 6.34 1.85 3/8x2-1/2 3.1 65RC3030020 66RC3030020 1.8 80 x 50 3.2 20.7 116.6 161.0 47.0 M10 x 64 1.4 3 x 2-1/2 1/8 300 4.51 6.34 1.85 3/8x2-1/2 2.9 65RC3030024 66RC3030024 1,8° 80 x 65 3.2 20.7 114.6 161.0 47.0 M10 x 64 1.3 4 x 2 1/4 300 5.83 7.52 2.01 1/2 x 3 4.8 65RC3040020 66RC3040020 1.2` 100 x 50 6.4 20.7 148.1 191.0 51.1 M12 x 76 2.2 4 x 2-1/2 1/4 300 5.83 7.52 2.01 1/2 x 3 4.8 65RC3040024 66RC3040024 1.20 100 x 65 6.4 20.7 148.1 191.0 51.1 M12 x 76 2.2 4 x 3 1/4 300 5.83 7.52 2.01 1/2 x 3 4.4 65RC3040030 66RC3040030 1.2° 100x80 6.4 20.7 148.1 191.0 51.1 M12x76 2.0 6 x 4 1/4 300 7.99 10.35 2.01 5/8 x 3-3/4 9 65RC3060040 66RC3060040 0.9° 150 x 100 6.4 20.7 202.9 262.9 51.1 M16 x 95 4.1 8 x 6 1/4 300 10.12 13.15 2.48 5/8 x 3-3/4 14.6 65RC3080060 66RC3080060 0.8° 200 x 100 6.4 20.7 257.0 334.0 63.0 M19 x 108 6.6 NOTES: 1. All bolts and gaskets identified by SCI logo. 2. 100%Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): • Temperature range: -30°F(-34°C) to+230°F(+110°C). 5. Gasket Grade T Nitrile(orange stripe)available: • Temperature range: -20°F(-29°C) to+180°F(+82°C). 6. See Installation Instructions on Page 20. 7. SMITH-COOPER Warranty(see page 19)only applies to assemblies made up using gaskets, housings, and bolts with the<>logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com r i: i, , 500 Series Hinged Flange Adapter U • ---- '.'• ---,, i r C0US N111 N I p' ED syN �� 0 APPROVED ,?6 III .,4491 ' 4 0 • lb _�� • 4: a,; 0 A -.- C -.- Fig. 65FH& 66FH-Hinged Flange Adapter Part Number Max Working Dimensions Flange Bolt Number Pipe Size Pipe OD Pressure A B C Size of Flange Weight . Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm Bolts LB/kg 2 2.375 300 6.00 4.75 0.75 5/8 x 3 3.6 65F113020 66FH3020 4 50 60.3 20.7 152.4 120.7 19.1 M16 x 76 1.6 • 2-1/2 2.875 300 7.00 5.50 0.88 5/8 x 3 3.6 65FH3024 66FH3024 4 65 73.0 20.7 177.8 139.7 22.4 M16 x 76 1.6 3 3.500 300 7.50 6.00 0.94 5/8 x3 4.8 65FH3030 66FH3030 4 80 88.9 20.7 190.5 152.4 23.9 M16 x 76 2.2 4 4.500 300 9.00 7.50 0.94 5/8 x 3 6.6 65FH3040 66FH3040 8 100 114.3 20.7 228.6 190.5 23.9 M16 x 76 3.0 6 6.625 300 11.00 9.50 1.00 3/4 x 3-1/2 8.4 65FH3060 66FH3060 8 150 168.3 20.7 279.4 241.3 25.4 M19 x 89 3.8 _ 8 8.625 300 13.50 11.75 1.12 3/4 x 3-1/2 14.3 65FH3080 66FH3080 8 200 219.1 20.7 342.9 298.5 28.4 M19 x 89 6.4 NOTES: - 1.All bolts and gaskets identified by SCI logo. 2. 100%Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): •Temperature range:-30°F(-34°C) to+230°F(+110°C). 5. Gasket Grade T Nitrile(orange stripe): •Temperature range:-20°F(-29°C) to+180°F(+82°C). 6. Matches class 125/150 flange dimensions. 7. See Installation Instructions on Page 17 8. SMITH-COOPER Warranty(see page 19)only applies to assemblies made up using gaskets, housings, and bolts with the<>logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com ® C (i� , IA)h 500 Series Short Radius Grooved Fittings ( j)1.II c0us .. APPROVED III 1 .----A 7 1 .40._ -� 13_j 1 • 1. ° lY'. A NPT C Ii DRAIN 1 NPT °•!' I________ I-A-'I I B--� DRAIN DRAIN 90° Elbow Tee Drain Cap Drain Elbow Fig. 65ES & 66ES- 90°Elbow, Short Radius Fig. 65TS & 66TS- Tee, Short Radius Part Number Nominal Actual Part Number Nominal Actual Pipe Size Pipe OD A Weight Pipe Size Pipe OD A Weight Painted Galv IN/mm IN/mm IN/mm LB/kg Painted Galv IN/mm IN/mm IN/mm LB/kg 65ES3020 66ES3020 2 2.375 2.75 1.7 2 2.375 2.75 2.4 65183020 66183020 50 60.3 69.9 0.8 50 60.3 69.9 1.1 65E83024 66E83024 2-1/2 2.875 3.00 3.1 65183024 66183024 2-1/2 2.875 3.00 3.6 65 73.0 76.2 1.4 65 73.0 76.2 1.6 65ES3030 66ES3030 3 3.500 3.38 4.0 3 3.500 3.38 5.3 65183030 66183030 80 88.9 85.9 1.8 80 88.9 85.9 2.4 65E83040 ` 66E83040 4 4.500 4.00 6.5 4 4.500 4.00 8.7 65183040 66183040 100 114.3 101.6 2.9 100 114.3 101.6 3.9 65E83050 66E83050 5 5.563 4.88 12.6 65183050 66183050 5 5.563 4.88 15.7 125 141.3 124.0 5.7 125 141.3 124.0 7.1 65E83060 66E83060 6 6.625 5.50 18.3 65183060 66183060 6 6.625 5.50 22.7 150 168.3 139.7 8.2 150 168.3 139.7 10.2 65E83080 66ES3080 8 8.625 6.81 25.5 8 8.625 6.94 38.7 65183080 66183080 200 219.1 173.0 11.5 200 219.1 176.3 17.4 500 Series Grooved Fittings w/ Drains Fig. 65DC & 66DC-Drain Cap Fig. 65DE & 66DE-Drain Elbow Part Number Nominal Actual Part Number Nominal Actual Pipe Size Pipe OD A Weight Pipe Size Pipe OD A B C Weight Painted Galv IN/mm IN/mm IN/mm LB/kg Painted Galv IN/mm IN/mm IN/mm IN/mm IN/mm LB/kg 65DC3020 660C3020 2 2.375 0.88 0.6 650E3020 660E3020 2 2.375 3.25 2.76 1.30 2.1 50 60.3 22.4 0.3 50 60.3 82.6 70.1 33.0 0.9 650C3024 66DC3024 2-1/2 2.875 0.88 1.0 650E3024 660E3024 2-1/2 2.875 3.75 2.70 1.68 5.2 65 73 22.4 0.5 65 73.0 95.3 68.6 42.7 2.3 - 650C3030 66DC3030 3 3.500 0.88 1.2 650E3030 660E3030 3 3.500 4.25 2.70 2.10 5.5 88.9 88.9 22.4 0.5 80 88.9 108.0 68.6 53.3 2.5 65DC3040 68DC3040 4 4.500 1.00 2.5 650E3040 66E1E3040 4 4.500 5.00 2.75 2.60 8.8 100 114.3 25.4 1.1 100 114.3 127.0 69.9 66.0 4.0 650C3050 660C3050 5 5.563 1.00 4.6 65013060 860(3060 6 6.625 6.50 2.75 3.65 18.7 125 141.3 25.4 2.1 150 168.3 165.1 69.9 92.7 8.4 650C3060 660C3060 6 6.625 1.00 6.1 650E3080 660E3080 8 8.625 7.75 2.75 4.57 28.6 . 150 168.3 25.4 2.7 _ 200 219.1 196.9 69.9 116.1 12.9 650C3080 660C3080 8 8.625 1.20 13.1 200 219.1 30.5 5.9 c UE us SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smithcooper.com '(r: ,V. :, 500 Series Mechanical Tee, Threaded 'tr t)v'. ) pm C � US • `` B APPROVED v. :: jilt 4 ma+ x A /AR ) c ,.fi ,. . f. it MY MY 11141/4, . .,,. ..,, .._ . ..)/pm- •3• Fig. 65MT& 66MT-Mechanical Tee, Threaded Part Number Size Hole Diameter Max Working Dimensions Equivalent Run x Branch +1/8, -0/+3.2, -0 Pressure A B C Length in Weight Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm Feet* LB/kg 65M13020004 66MT3020004 2 x 1/2 1-1/2 500 2.50 4.96 2.80 3.1 50 x 15 38 34.5 64.0 126.0 71.1 1.4 M113020006 66MT3020006 2 x 3/4 1-1/2 500 2.50 4.96 2.80 3.1 50 x 20 38 34.5 64.0 126.0 71.1 1.4 65M13020010 66M13020010 2 x 1 1-1/2 500 2.50 4.96 2.80 2 3.0 50 x 25 38 34.5 64.0 126.0 71.1 1.4 2 x 1-1/4 1-3/4 500 2.80 4.96 2.80 3.5 65M13020012 66M13020012 4 50 x 32 45 34.5 70.1 126.0 71.1 1.6 2 x 1-1/2 1-3/4 500 2.80 4.96 2.87 3.6 65MT3020014 66MT3020014 9 50 x 40 45 34.5 70.1 126.0 72.9 1.6 65MT3024004 66M13024004 2-1/2 x 1/2 1-1/2 500 2.80 5.20 2.80 3.0 65 x 15 38 34.5 70.1 132.1 71.1 1.4 65MT3024006 66MT3024006 2-1/2 x 3/4 1-1/2 500 2.80 5.20 2.80 3.0 65 x 20 38 34.5 70.1 132.1 71.1 1.4 2-1/2 x 1 1-1/2 500 2.80 5.20 2.80 3.0 65MT3024010 66MT3024010 65 x 25 38 34.5 70.1 132.1 71.1 2 _ 1.4 65M13024012 66M13024012 2-1/2 x 1-1/4 1-3/4 500 3.00 5.20 3.03 4 3.5 65 x 32 45 34.5 75.9 132.1 77.0 1.6 65MT3024014 66MT3024014 2-1/2 x 1-1/2 2 500 3.00 5.20 3.27 9 3.6 65 x 40 51 34.5 75.9 132.1 83.1 1.6 65MT3030010 66M13030010 3 x 1 1-1/2 500 3.10 5.91 2.80 2 3.3 80 x 25 38 34.5 78.0 150.1 71.1 1.5 3 x 1-1/4 1-3/4 500 3.27 5.91 3.03 3.8 65M13030012 66M13030012 4 80 x 32 45 34.5 83.1 150.1 77.0 1.7 3 x 1-1/2 2 500 3.50 5.91 3.27 4.1 65MT3030014 66M13030014 80 x 40 51 34.5 88.9 150.1 83.1 3 • 1.8 65M13030020 66MT3030020 3 x 2 2-1/2 500 3.50 5.91 3.78 5 4.9 80 x 50 64 _ 34.5 88.9 150.1 96.0 2.2 65M13040010 66MT3040010 4 x 1 1-1/2 500 3.54 7.09 2.80 2 3.6 100 x 25 _ 38 34.5 _ 89.9 180.1 71.1 1.6 4 x 1-1/4 1-3/4 500 3.78 7.09 3.03 4.0 65MT3040012 66M13040012 4 100 x 32 45 34.5 96.0 180.1 77.0 1.8 • 65MT3040014 66M13040014 4 x 1-1/2 2 500 4.02 7.09 3.27 3 4.2 100 x 40 51 34.5 102.1 180.1 83.1 1.9 NOTES: 1. All bolts and gaskets identified by SCI logo. 5. Gasket Grade T Nitrite(orange stripe): 2. 100%Magnetic particle inspection of each bolt. Each • Temperature range: -20°F(-29°C) to +180°F(+82°C). bolt has a minimum tensile strength of 110.000 psi. 6. See Installation Instructions on Page 17 3. Gaskets are pre-lubricated. 7. SMITH-COOPER Warranty(see page 19) only applies to assemblies 4. Gasket Grade E EPDM(green stripe): made up using gaskets, housings, and bolts with the 4 logo. /�•Temperature range: -30°F(-34°C) to+230°F(+110°C). ci IM. us SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smithcooper.com FM - - 4, t (, -wa is 500 Series Mechanical Tee, Grooved • C43 US ________1 APPROVED • 1 1 tem A mi y NI I I II I lil I I ki I\N i...c.. I 1- . . - 4.1 . 1 NirrN W ,•• 1 Fig. 65MG & 66MG-Mechanical Tee, Grooved Part Number Size Hole Diameter Max Working Dimensions Equivalent Run x Branch +1/8, -07+3.2, -0 Pressure A B C Length in Weight Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm Feet* LB/kg 3 x 1-1/4 1-3/4 500 3,50 5.90 3.00 3.7 65MG3030012 66MG3030012 4 80x32 45 34.5 89.9 150.1 77.0 1.7 3 x 1-1/2 2 500 3.50 5.90 3.30 3.8 65MG3030014 66MG3030014 80x40 51 34.5 89.9 150.1 83.1 3 1.7 65MG3030020 66M03030020 3 x 2 2-1/2 500 3.50 5.90 3.80 5 4.6 80 x 50 64 34.5 89.9 150.1 96.0 2.1 65MG3040012 66MG3040012 4 x 1-1/4 3/4 500 4.00 7.10 3.00 4 3.6 100 x 32 45 34.5 102.1 180.1 77.0 1.6 65M03040014 66MG3040014 4 x 1-1/2 2 500 4.00 7.10 3.30 3 3.9 • 100 x 40 51 34.5 102.1 180.1 83.1 1.8 65MG3040020 66MG3040020 4 x 2 2-1/2 500 4.00 7 10 3 90 5 4.6 100 x 50 64 34.5 102.1 180.1 100.1 2.1 65MG3040024 66M63040024 4 x 2-1/2 2-3/4 500 4.00 7 20 4 20 11 5.0 100 x 65 70 34.5 102.1 183.9 106.9 2.3 65M03040030 66MG3040030 4 x 3 3-1/2 500 4.10 7.20 4.80 13 6.4 100 x 80 _ 89 34.5 104.9 183.9 120.9 2.9 65MG3050014 66MG3050014 5 x 1-1/2 2 500 4.80 8 00 3 30 3 7.6 125 x 40 51 34.5 _ 120.9 202.9 83.1 3.4 65MG3050020 66MG3050020 5 x 2 2-1/2 500 4.80 8 70 3 90 5 _ 8.0 125 x 50 64 34.5 120.9 220.0 100.1 3.6 65MG3050024 66M63050024 5 x 2-1/2 2-3/4 500 4.80 8.70 4.20 11 8.0 125 x 65 70 34.5 120.9 220.0 106.9 3.6 65MG3050030 66M03050030 5 x 3 3-1/2 500 4.80 8.70 4.90 13 8.8 125 x 80 89 34.5 120.9 220.0 125.0 4.0 65MG3060012 66MG3060012 6 x 1-1/4 1-3/4 500 5.10 9.10 3.00 4 4.8 150 x 32 45 34.5 130.0 231.9 77.0 2.2 65M03060014 66MG3060014 6 x 1-1/2 2 500 5.10 9.10 3.30 3 5.1 150 x 40 51 34.5 130.0 231.9 83.1 2.3 65MG3060020 66MG3060020 6 x 2 2-1/2 500 5 10 9.80 3.90 5 5.6 150 x 50 64 34.5 130.0 247.9 100.1 2.5 65MG3060024 66M13060024 6 x 2-1/2 2-3/4 500 5.10 9.80 4.20 11 7 6 150 x 65 70 34.5 130.0 247.9 106.9 3.4 65M63060030 66M63060030 6 x 3 3-1/2 500 5.10 9.80 4.90 13 8.4 150 x 80 89 34.5 130.0 247.9 125.0 3.8 - 65M63060040 66M63060040 6 x 4 4-1/2 500 5.40 9.80 5.90 15 10.1 150 x 100 114 34.5 136.9 247.9 150.1 4.5 65M63080020 66M63080020 8 x 2 2-1/2 500 6.26 11.81 3.94 5 11.6 200 x 50 64 34.5 159.0 300.0 100.1 5.2 65MG3080024 66M63080024 8 x 2-1/2 2-3/4 500 6.26 1 81 4.21 11 11.6 200 x 65 70 34.5 159.0 300.0 106.9 5.2 65MG3080030 66M63080030 8 x 3 3-1/2 500 6.26 11.81 4.92 13 11 6 200 x 80 89 34.5 159.0 300.0 125.0 5.2 65MG3080040 66M63080040 8 x 4 4-1/2 500 6 38 11.81 5.91 15 12.5 200 x 100 114 34.5 162.1 300.0 150.1 5.6 NOTES: 1. All bolts and gaskets identified by SCI logo. 5. Gasket Grade T Nitrite(orange stripe): 2. 100%Magnetic particle inspection of each bolt.Each •Temperature range:-20°F(-29°C)to+180°F(+82°C). bolt has a minimum tensile strength of 110,000 psi. 6. See Installation Instructions on Page 20. 3. Gaskets are pre-lubricated. 7. SMITH-COOPER Warranty(see page 19)only applies to assemblies 4. Gasket Grade E EPDM(green stripe): made up using gaskets, housings,and bolts with the. .logo. •Temperature range:-30°F(-34°C)to+230°F(+110°C). 8. Equivalent Length in Feet of Schedule 40 Outlet Pipe with a Hazen-Williams Coefficient of 120 per UL 213. c aL us SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com ■ , (it i•t)h 500 Series Strap Tee, Threaded B \ C 0 US + ` APPROVED . . '` r i 0 i I § �� � �' �i�� nw.,I I ' (9 „ t. Or 1 c k 1 1 .,r�Fy� W #.,.,,.,.. y, Fig. 65MU& 66MU-Strap Tee, Threaded Part Number Size Hole Diameter Max Working Dimensions Equivalent Run x Branch +1/8, -0/+3.2, -0 Pressure A B C Lenght in Weight Painted GaIv IN IN/mm PSI/bar IN/mm IN/mm IN Feet* LB/kg 65MU3012004 66MU3012004 1-1/4 x 1/2 1-1/4 300 1.65 3.54 2.28 3.1 32 x 15 32 20.7 41.9 89.9 57.9 1.4 - 65MU3012006 66MU3012006 1-1/4 x 3/4 1-1/4 300 1.85 3.54 2.28 3.1 32 x 20 32 20.7 47.0 89.9 579 1.4 65MU3012010 66MU3012010 1-1/4 x 1 1-1/4 300 2.13 3.54 2.28 5 3.0 32 x 25 32 20.7 54.1 89.9 579 1.4 65MU3014004 66MU3014004 1-1/2 x 1/2 1-1/4 300 1.77 3.54 2.28 3.1 40 x 15 32 20.7 45.0 89.9 579 1.4 65MU3014006 66MU3014006 1-1/2 x 3/4 1-1/4 300 1.97 3.54 2.28 3.1 40 x 20 32 20.7 50.0 89.9 57.9 1.4 65MU3014010 66MU3014010 1-1/2 x 1 1-1/4 300 2.24 3,54 2.28 5 3.0 40 x 25 32 20.7 56.9 89.9 57.9 1.4 651003020004 66MU3020004 2 x 1/2 1-1/4 300 2.01 3.74 2.28 3.1 50 x 15 32 _ 20.7 51.1 95.0 57.9 1.4 65MU3020006 661%403020006 2 x 3/4 1-1/4 300 2.20 3.74 2.28 3.1 50 x 20 32 20.7 55.9 95.0 57.9 1.4 65M03020010 66MU3020010 2 x 1 1-1/4 300 2.48 3.74 2.28 5 3.0 50 x 25 32 20.7 63.0 95.0 57.9 1.4 65MU3024004 66MU3024004 2-1/2 x 1/2 1-1/4 300 2.26 4.29 2.28 3.0 65 x 15 32 20.7 57.4 109.0 579 1.4 65MU3024006 66=024006 2-1/2 x 3/4 1-1/4 300 2.50 4.29 2.30 3.0 65 x 20 32 20.7 62.5 109.0 57.9 1.4 _ - 65MU3024010 66MU3024010 2-1/2 x 1 1-1/4 300 2.70 4.29 2.30 5 3.0 65 x 25 32 20.7 69.6 109.0 57.9 1.4 NOTES: 1.All bolts and gaskets identified by SCI logo. " 2. 100%Magnetic particle inspection of each bolt. Each bolt - has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): • •Temperature range: -30°F(-34°C) to+230°F(+110°C). 5. Gasket Grade T Nitrile(orange stripe): •Temperature range:-20°F(-29°C) to+180°F(+82°C). 6. See Installation Instructions on Page 17. 7 SMITH-COOPER Warranty(see page 19)only applies to assemblies made up using gaskets, housings, and bolts with the sC logo. 8. Equivalent Length in Feet of Schedule 40 Outlet Pipe with a Hazen-Williams Coefficient of 120 per UL 213. 9. 1"outlets not listed by UL for direct connection to 1"sprinkler heads. c 6.L us SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com ® _ _ ,. f ark: ink UL Listed/FM Approved Sprinkler Pipe and Warranty Information ( ;± ,)vi ► SCI COOPLOKTM Grooved Couplings are UL Listed and FM Approved for use on the following types of sprinkler pipe:* c ® us APPROVED PIPE NAME MANUFACTURER Dyna-Thread®, Central-Thread®, XL°, XL-II®, Dyna-Flow®, Allied Tube and Conduit Corp. Super 401 Super-Flo°,TL°, Central 7®, BLT® Eddylite®, Eddy Flow®, Eddy Thread 40® Bull Moose Tube Co. — Gal-7® IDOD Systems Co. EZ-Flow® Northwest Pipe & Casing Co. WLS®, Mega-Flow®, Mega-Thread®, MLT®, GL® Wheatland Tube Company Steady Flow®, Steady Thread® Welded Tube Corp. . Fire-Flo°, EZ-Thread® Youngstown Tube Co. Tex-Flow® Tex-Tube International SPSF® Yieh Phui Enterprise Co. Ltd. *NOTE: Includes any manufacturer of Schedule 10 or Schedule 40 steel pipe. Check www.SmithCooper.com for updated list of UL Listed/FM Approved sprinkler pipe manufacturers. WARRANTY AND LIMITATIONS OF LIABILITY SMITH-COOPER INTERNATIONAL(SCI)warrants to its initial purchaser only,that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of five years from the date of delivery to our initial purchaser. Should any failure to conform to this warranty appear within five years after the date of the initial delivery to our initial purchaser,SCI will,upon written notification thereof and substantiation that the goods have been stored,installed,maintained and operated in accordance with recognized engineering and piping practices and industry standards,correct such defects by suitable repair or replacement(which alternative shall be at the discretion of SCI)of product at SCI's own expense upon return of the defective part to SCI. In the event that SCI elects to replace the defective product,SCI shall pay up to$50 per defective product for total cost of replacement. In the event of multiple claims, such payment shall be no greater than$1,000 for each installation project. This warranty applies only during normal use that meets the above referenced conditions of installation and operation and is absolutely void if the product has been damaged after purchase or if it has been misused,repaired,altered or modified in any manner whatsoever. SCI shall not warranty any of its products if any portion of the product including without limitation,any component,gasket,housing or bolt has been modified,altered,remanufactured or replaced in any manner by any customer, user of the product or third party. Correction of non-conformities,in the manner and for the period of time provided above,shall constitute fulfillment of all liabilities of SCI to our initial purchaser,with respect to the goods,whether based on contract,negligence,strict tort,or otherwise. It is the intention of SCI that no warranty of any kind,whether expressed or implied - shall pass through our initial purchaser to any other person or corporation. No returns will be allowed unless prior written permission of SCI is first obtained. Buyers shall be responsible for all costs of transportation as well as a restocking charge. This warranty is exclusively for the benefit of the initial purchaser of this product from SCI and,except to the extent prohibited by applicable law,the foregoing warranty is in lieu of all other warranties,express or implied,including but not limited to warranties of fitness or merchantability. LIMITATIONS OF LIABILITY:SCI shall not under any circumstances be liable for special or consequential damages such as,but not limited to damage to loss of other property or equipment,loss of profits or revenue,cost of capital,cost of purchased or replacement goods,claims of customers of our initial purchaser,any labor cost for repair or replacement of the product or damage caused by the product. The remedies of our initial purchaser,and all others,set forth herein are exclusive,and the liability of SCI with respect to same shall not,except as expressly provided herein,exceed the price of the SCI products on which such liability is based. DISCLAIMER:Smith-Cooper International cannot be held responsible for omissions or errors in this catalog. Please refer to www.smithcooper.com for current information. c 4L us SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Iron Threaded Fittings ast ____________________ . .. . .. . . . • , .„," . „ ,..,,,„„„...,„ , .. .. ,, ..... , , .. . . , • Y ( .%::t< !• 1i� V • • R l. x k :.* 4 1 l •V - . 1 SMITH t COOPER® I N T E R N A T I O N A L Cast Iron Threaded Fittings Specifications • 4' branded cast iron threaded fittings are UL Listed and FM Approved at 300psi • Rated to 125# WSP • Casting date on each fitting C 13 US • Grey iron castings conform to ASTM A126 LISTED • Cast iron fitting dimensions conform to ASME B16.4 Class 125 • NPT threads on fittings conform to ASME B1.20.1 APPROVED • Cast iron fittings have SCI Trademark and are 100% air tested • Manufacturing facility is ISO 9001:2008 and ISO 14001 ' Cast Iron Fittings - Class 125 UL/FM I Warn'?LW; C ® US 41101.. APPROVED _ • Fig. 37E 1 - 90°Elbow LISTED A Size Part Number A Packing Weight 1` IN IN Inner Master LB 1/2 37E 1004 1.13 90 180 0.3 --r- 3/4 37E 1006 1.31 50 100 0.5 1 37E 1010 1.50 35 70 0.8 A ��■■I 1-1/4 37E 1012 1.75 20 40 1.3 1-1/2 37E 1014 1.94 15 30 1.7 2 37E 1020 2.25 7 14 2.7 2-1/2 37E 1024 2.70 4 8 4.3 Fig. 37RE1 - 90°Reducing Elbow Size A B Pack ing Weight 1111 A � IN Part Number IN IN Inner Master LB 1 x 1/2 37RE1010004 1.36 1.26 50 100 0.5 I 1 x 3/4 37RE1010006 1.45 1.38 40 80 0.7 1-1/4 x 1/2 37RE1012004 1.53 1.34 32 64 0.8 B 1-1/4 x 3/4 37RE1012006 1.63 1.45 28 56 0.9 1 1/4 x 1 37RE1012010 1 67 1.58 25 50 1.0 1-1/2 x 1/2 37RE1014004 1.75 1.52 25 50 1.0 1-1/2 x 3/4 37RE1014006 1.75 1.52 20 40 1.1 1-1/2 x 1 37RE1014010 1.80 1.65 18 36 1.3 1-1/2 x 1-1/4 37RE1014012 1.88 1.82 14 28 1.5 2 x 1/2 37RE1020004 1.97 1.60 15 30 1.4 2 x 3/4 37RE1020006 1.97 1.60 15 30 1.6 2 x 1 37RE1020010 2.02 1.73 12 24 1.8 2 x 1-1/2 37RE1020014 2.16 2.02 10 20 2.3 Fig. 37F 1 -45° Elbow Illi Size A Packing Weight Part Number A� IN IN Inner Master LB 1 37F 1010 1.26 40 80 0.7 \ � 1-1/4 37F 1012 1.29 22 44 1.2 1-1/2 37F 1014 1.44 16 32 1.5 ��I IA 2 37F 1020 1.69 8 16 2.6 Fig. 37T 1 - Tee Size A Packing Weight IN Part Number IN _ Inner Master LB 1 ��-1� IA 1/2 37T 1004 1.13 60 120 0.4 3/4 37T 1006 1.31 30 60 0.7 NMI 1 37T 1010 1.50 20 40 1.1 �" 1-1/4 37T 1012 1.75 12 24 1.8 f 1-1/2 37T 1014 1.94 8 16 2.4 A A 2 _ 37T 1020 2.25 5 _ 10 3.8 • Fig. 37RC1 -Hex Coupling • itSize Part Number A Packing Weight itvip IN IN Inner Master LB 1 x 1/2 37RC1010004 1.69 60 120 0.5 A 1 x 3/4 37RC1010006 1.69 50 100 0.6 1E111 x 1 (not hex) 37RC1020010 I 2.81 I 16 I 32 I 1.5 Q7 CUM-LC(11PFR INJTPRNA'I'IflNAI.® •_ Tni.1. PR PP 1-Rn(1-7AA-(H17h • FAX 1122.1 R9(1-44SA • wwwcmirhrooner_cnm '_( Cast Iron UL/FM Fittings - Class 125 UL g / 141111l'Y P1U:: C ® US 4114> APPROVED Fig. 37RT1 -Reducing Tee LISTED - I Size Part Number A B C Packing Weight _ awl. T IN IN IN IN Inner Master LB C 1 x 1/2 37RT1010004 1.26 1.26 1.36 25 50 0.9 1 x 1/2 x 1 37RT1010004010 1.50 1.36 1.50 24 48 0.9 __� 1 x 3/4 37RT1010006 1.38 1.38 1.45 22 44 1.0 1 x 3/4 x 1 37RT1010006010 1.50 1.45 1.50 20 40 1.0 1 x 1-1/4 37RT1010012 1.67 1.67 1.58 15 30 1.4 B A 1-1/4 x 1/2 37RT1012004 1.34 1.34 1.53 18 36 1.3 1-1/4 x 1/2 x 1-1/4 37RT1012004012 1.75 1.53 1.75 18 36 1.4 1-1/4 x 3/4 37RT1012006 1.45 1.45 1.62 15 30 1.4 1-1/4 x 3/4 x 1-1/4 37RT1012006012 1.75 1.62 1.75 15 30 1.5 1-1/4 x 1 37RT1012010 1.58 1.58 1.67 15 30 1.6 1-1/4 x 1 x 1/2 37RT1012010004 1.34 1.26 1.53 20 40 1.1 1-1/4 x 1 x 3/4 37RT1012010006 1.45 1.38 1.63 16 32 1.2 1-1/4 x 1 x 1 37RT1012010010 1.58 1.50 1.69 15 30 1.4 1-1/4 x 1 x 1-1/4 37RT1012010012 1.75 1.69 1.75 12 24 1.6 1-1/4 x 1 x 1-1/2 37RT1012010014 1.88 1.80 1.82 12 24 1.8 1-1/4 x 1-1/2 37RT1012014 1.88 1.88 1.82 10 20 2.0 1-1/2 x 1/2 37RT1014004 1.41 1.41 1.66 12 24 1.6 1-1/2 x 1/2 x 1-1/4 37RT1014004012 1.81 1.56 1.88 12 24 1.7 1-1/2 x 1/2 x 1-1/2 37RT1014004014 1.94 1.66 1.94 12 24 1.8 1-1/2 x 3/4 37RT1014006 1.52 1.52 1.75 12 24 1.8 1-1/2 x 3/4 x 1-1/4 37RT1014006012 1.94 1.66 1.88 12 24 1.7 1-1/2 x 3/4 x 1-1/2 37RT1014006014 1.94 1.75 1.94 12 24 1.9 1-1/2 x 1 37RT1014010 1.65 1.65 1.80 10 20 1.9 1-1/2 x 1 x 1/2 37RT1014010004 1.44 1.25 1.69 18 36 1.3 1-1/2 x 1 x 3/4 37RT1014010006 1.50 1.44 1.75 15 30 1.4 1-1/2 x 1 x 1 37RT1014010010 1.65 1.50 1.80 12 24 1.6 1-1/2 x 1 x 1-1/4 37RT1014010012 1.82 1.67 1.88 10 20 1.8 1-1/2 x 1 x 1-1/2 37RT1014010014 1.94 1.80 1.94 8 16 2.1 1-1/2 x 1-1/4 37RT1014012 1.82 1.82 1.88 8 16 2.2 1-1/2 x 1-1/4 x 1/2 37RT1014012004 1.41 1.34 1.66 15 30 1.5 1-1/2 x 1-1/4 x 3/4 37RT1014012006 1.52 1.45 1.75 12 24 1.6 1-1/2 x 1-1/4 x 1 37RT1014012010 1.65 1.58 1.80 12 24 1.8 1-1/2 x 1-1/4 x 1-1/4 37RT1014012012 1.82 1.75 1.88 10 20 2.1 1-1/2 x 1-1/4 x 1-1/2 37RT1014012014 1.94 1.88 1.94 8 16 2.3 1-1/2 x 1-1/4 x 2 37RT1014012020 2.16 2.10 2.02 6 12 2.7 1-1/2 x 2 37RT1014020 2.16 2.16 2.02 5 10 2.9 2 x 1/2 37RT1020004 1.49 1.49 1.88 8 16 2.6 2 x 3/4 37RT1020006 1.60 1.60 1.97 8 16 2.6 C 2 x 1 37RT1020010 1.73 1.73 2.02 6 12 2.9 A 2 x 1 x 2 37RT1020010020 2.25 2.02 2.25 5 10 3.1 s ' 2 x 1-1/4 37RT1020012 1.90 1.90 2.10 5 10 3.2 T 2 x 1-1/4 x 2 37RT1020012020 2.25 2.10 2.25 5 10 3.2 2 x 1-1/2 37RT1020014 2.02 2.02 2.16 5 10 3.3 - 2 x 1-1/2 x 1/2 37RT1020014004 1.49 1.41 1.88 8 16 2.1 R 2 x 1-1/2 x 3/4 37RT1020014006 1.60 1.52 1.97 8 16 2.2 2 x 1-1/2 x 1 37RT1020014010 1.73 1.65 2.02 8 16 2.4 0 2 x 1-1/2 x 1-1/4 37RT1020014012 1.90 1.82 2.10 7 14 2.7 N 2 x 1-1/2 x 1-1/2 37RT1020014014 2.02 1.94 2.16 7 14 2.9 2 x 1-1/2 x 2 37RT1020014020 2.25 2.16 2.25 5 10 3.4 2 x 2-1/2 37RT1020024 2.60 2.60 2.39 3 6 4.6 SAII'I'11-COOPER INTERNA'1'IONAI® • TOIJ.FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithc000er.com 9S Ductile Iron Threaded Fittings • .,. ...., . . ,..h.,,, _____ ......,._. ... ,....:.,„:,...„......, ,,,..., h. ...,..„,. ,-...:„. ,,:,:.;„.... ... ... .. .,,,,,h. .td'x.. ..., . .,.... , ... .. h,. ,, t ' k .„....4.' ' '..'''' '--'•.4'.-.,41,... .,";Ai', `'---,-"Y' ;',A-ih,f',*'14.,11:,..1--'.'-;.-' 'tt r x.-, ol �fv ,J e '¢ .v . a. y -_ x4;7.....:..'., SMITHCOOER� I N T E R N A T I O N A L Ductile Iron Threaded Fittings Specifications • branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP 41) Ductile iron castings conform to ASTM A536 C US • LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 44:; • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 • 350 420 400 400 450 380 500 360 550 340 600 320 • 650 300 • - Ductile Iron Fittings-Class 300 UL/FM I QUALITY PLUS C (11) US APPROVED - Fig. 35E 3- 90° Elbow LISTED A • Size Part Number A Packing Weight in in Inner Master lb t4111111. 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 ' A 1 35E 3010 1.50 40 80 0.5 1=x! 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow 1 B Size Part Number A B Packing Weight ■,,_.� in in in Inner Master lb 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 I� 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 '�II' 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 I 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 1 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 - 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow i Size Part Number A Packing Weight A in in Inner Master lb /' , /� 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 "tiIIMM t1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 • 1 1/2 35F 3014 1.44 20 40 1.0 I IA 1-1/2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size part 35T Number A Packing Weight . • -a--sti, [li I in Inner Master Ib 1i/n2 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 II 1-1/4 35T 3012 1.75 10 20 1.1 0 35T 3010 1 50 25 50 A A 1-1/2 35T 3014 1.94 0 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 Q!41'I`LT r'r C 1)I'D 1■T'I'RRN A'1'Tr1MA I® • 'IY11 I 1.:111:1 Li/1_7ij,_1I17! • 1:1V ,2721 52011 ;11 z. • ..............:.�,,.,.,..,,_r • s.CI 3 Ductile Iron Fittings- Class 300 UL/FM I QUALITY PLUS c ® uS APPROVED Fig. 35RT3-Reducing Tee LISTED • 'Elam Size part Number A B C Packing Weight in in in in Inner Master Ib C 3/4x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 I- 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 I 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 • 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1--.'"•; 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 0;1 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 E 1-1/2 x 1-1/4 x 1/2 35 RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 h` 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 . 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 ',? 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 A. 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x 1-1/2x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35RT3-Bull Head Tee Size Part Number A B C Packing Weight i..tr IC in in in in Inner Master lb 3/4 x 1 35BT3006010 1.45 1.45 1 37 30 60 0.6 �1�1 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A B 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 CA 111.1-1_r()(11,1;R IN'I'FRNA'I'l(INA I.69 • 'I'()1 I. FRF ■ 1_S21111_7kt;_l1(17(, • I:A\11,115:g11_11S(, • ...... cnnirhrn,n,•r∎•iu,1 111 • `Zy I ucti e ron fittings- ass I I . .,QUALM PLUS c ® us APPROVED A_ Fig. 35CP3 -Straight Coupling with Ribs LISTED Size A Packing Weight 6r�" in Part Number in Inner Master lb 1/2 35C P3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight p, in in Inner Master lb \ A 1 x 1/2 35RC3010004 1.69 80 160 0.3 - 1 x 3/4 35RC3010006 1.69 60 120 0.4 • ; 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight in in Inner Master lb B 1 x 1/2 35HB3010004 1.06 180 360 0.2 it : I 1 x 3/4 35HB3010006 1.06 180 360 0.1 A 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 rk I 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 C i: 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 1 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug „..._. Size A Packing Weight Part Number in in Inner Master Ib 1/2 35SP3004 0.94 600 1200 0.07 . "I 3/4 35SP3006 1.12 350 700 0.1 IA 1 35SP3010 1.25 200 400 0.1 1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight / to in Part Number in Inner Master lb .�� um • . . 1 35U 3010 2.19 20 40 1 0 1111 I 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 '�`� 2 35U 3020 3.12 6 12 2.4 11 2 l'\11'1`1I (`(\(\III:U IT%J'I'I:I?TvAvI'I(iN'AI , - 'I'(\l I 1:1)1:I: 1 l'1111 71,i_ 111171. - 1:\V i1111 I Imo/ - .. .. ...:.I,,. .,.. < CJ - Ductile Iron Fittings- Class 300 UL/FM JUAL1T7 PLUS C ® US APPROVFO - Fig. 35X 3— Cross LISTED y - T—SIT--� Size A Packing Weight Part Number �– I�I � in in Inner Master lb `� A 1 35X 3010 1.50 20 1-1/4 35X 3012 1.75 12 24 1 4 • �� ---I--- �I A 1-1/2 35X 3014 1.94 2 35X 3020 2.25 6 12 2 8 �IIi - B B Fig. 35RX3—Reducing Cross `--'_�� Size Part Number A B Packing Weight A !� �A in in in Inner Master lb 1 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 i 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 I IA 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3— Cap Size part Number A Packing Weight I 1 A i. in Inner Master . '� ? 35C 3004 (!;;7 600 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1 1 6 1 1 0 220 0.2 D 1-1/4 35C 3012 1 28 70 140 0.4 U 1-1/2 35C 3014 1 33 100 0.5 C 2 35C 3020 1.45 25 50 0.8 T 2-1/2 35C 3024 1.70 _ °.8 1.6 I L E Fig. 35BC3—Beam Clamp MI Size Part Number A Packing Weight A_ , ■ in . 35BC3003 0175 Inner Maooer olb ■t 1/2 35BC3004 0.75 80 160 0.5 1k, i■—■ era e'tI'l-IJ Onnrnr:R 1 ?'l'1-u1TA'I'TJIXTAI ® - •IVNI I I:IJI:I: 1 cnn '7r_! n0'4. - L`AY VI/21 40/1 AA C4 ..... .. %A. 11 A Pipe Hangers Fig. 2 - Adjustable Band Hanger (B-Line B3170) c UL us Fig. 2F - Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line B3170F) LISTED `* Size Range: ®TOLCO Fig. 2 - 21/2"(65mm)thru 6"(150mm)pipe ' Fig. 2F - 21/2"(65mm)thru 6"(150mm)pipe '.'k " • Material: Pre-Galvanized Steel B . 0 Function: Recommended for the suspension of non- I/ insulated pipe or insulated pipe with B3151 shield. D Fig. 2NFPA accomodates the reduced rod schedule of the National Fire Pretection Association Pamphlet 13. Approvals: Factory Mutual Engineering Approved. -J Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E&A-A-1192A Type 10 and Fig.2 Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. _ Standard Finish: Pre-Galvanized � ,f Note: Available in Stainless Steel material. `-s.r- . Order By: Part number and finish. c B /0( 41, D 141100.,... kiloil0 Fig.2 Fig.2F Nominal Pipe Size Rod Size B C D Max.Rec.Loa Approx Wt./100 Part No. in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (Ids lbs. (kg) 2-21/2 21/2" (65) 1/2"-13* 53/4' (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) 2-3 3" (75) 1/2" 13* 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2-31/2 31/2" (90) 1/2"-1 3* 73/8" (187.3) 51/4" (133.3) 21/8 (54.0) 600 (2.67) 52 (23.6) 2-4 4" (100) 5/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2-5 5" (125) 5/8" 11 ** 9" (228.6) 61/8 (155.6) 21/4 (57.1) 1250 (5.56) 97 (44.0) 2-6 6 (150) 3/4"-10** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) Fig.2F Nominal Pipe Size Rod Size B C D Max.Rec.Load Approx Wt./100 s Part No. in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 2F-21/2 21/2 (65) 1/2"-13* 53/4" (146.0) 41/4 (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) *' 2F-3 3" (75) 1/2"-13* 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) • 2F-31/2 31/2" (90) 1/2"-13* 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6) 2F-4 4" (100) 5/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2F-5 5" (125) 5/8"-11 ** 9 (228.6) 61/8 (155.6) 21/4 (57.1) 1250 (5.56) 97 (44.0) 2F-6 6" (150) 3/4"-10** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) *3/8 nut is used when requested. **1/2 nut is used when requested. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line h„ ie.41F_1111 59 Pipe Hangers&Supports Threaded Accessories Fig. B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) ®TOLCO Fig. B3205L - Threaded Rod (right& left hand threads) • - Size Range: 3/8"-16 thru 3"-4 rod TL Ill A Specify Length lllllllll�� Material: Steel • Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown.Also TL l available with left and right hand threads-specify Fig. B3205L when ordering. 1��1h1 A Maximum Temperature: 750°F(399°C) % Thread Size Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'1' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 133205-7/8 x'L' 7/8"-9 31/2 (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. Fig. ATR - All Threaded Rod (TOLCO Fig.99&Fig. 100) Size Range: 3/8"-16 thru 11/2"-6 rod in 10'(3.05m) lengths � ���" 1� Material: Steel Maximum Temperature: 750°F(399°C) :,'',\���1 Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. '���` �111� Order By: Figure number, rod size, length and finish 1 Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. r • Part No. Threads Recommended Load Approx.Wt/100 FL Lbs.Size Per Inch Lbs. (kN) bs. (kg) }- ATR 1/4"x'1' 20 240 (1.07) 12 (5.44) ATR 3/8"x'1' 16 730 (3.24) 29 (13.15) . :-t ATR 1/2"x'L' 13 1350 (6.00) 53 (24.04) ATR 5/8"x'L' 11 2160 (9.60) 89 (40.37) ATR 3/4"x'L' 10 3230 N' 123 55.79 ATR 7/8"x'L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. VERTICAL MOUNT SAMMYS® SAMMYS® for Steel Installs VERTICALLY into the bottom of steel structures easily and quickly/ ti Product Features eO aril in9 •Made with Tekse self-drilling fasteners- p req unreel no pre-drilling required. •Install into steel range from ( 22 gauge—1/2"thicknesses. •Saves time from traditional methods. UAADE 1a •Reduces installation cost. sAL •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. FM Test Approvals Rod Part Model Screw Ultimate UL Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) bs Thick Thick Qty Qty _ 1/4" 8024957 DSTR 100• 1/4-20 x 1"TEKS 3 1510(20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4' 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970(16 ga.) .036"-20 ga 3/16' 25 125 • 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8030957 TEK 500 12-24 x 1-1/2"TEKS 5 3125(3/16") .187"-3/16" 1/2" 25 125 _ Q 3/8" 8038957 DSTR 1• 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 44.Q 3/8" 8037957 DSTR 1-1/2. 12-24 x 1-1/2"TEKS 5 1510(3/16") 1500 1475 .060'-16 ga. 1/2" 25 125 Q 3/8" 8039957 DSTR 516' 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446(20 ga.) .036"-20 ga 3/16" 25 125 #14 Black 970(16 ga.) Nut Driver 446 (20 ga.) Part#8113910 3/8" 8077925 DST 10-SS 1/4-14 x 1"TEKS 3 970(16 ga) .036"-20 ga 3/16" 25 125 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446(20 g a.) .036"-20 g a 3/16" 25 125 970(16ga.) 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2"TEKS 3 446(20 ga.) .036"-20ga 3/16" 25 125 970(16ga.) 3/8• 8042957 DST 20 1/4-14 x 2 TEKS'3 446(20 ga.) .036'-20 ga 3/16' 25 125 970(16 ga.) 3/8" 8043957 DST 25 1/4-14 x 2-1/2"TEKS 3 446(20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4.14 x 3"TEKS 3 446(20 ga.) .036"-20 ga 3/16' 25 125 970(16 ga.) Q 3/8" 8045957 DST 516 5/16-18 x 1-1/4"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 1/8" 25 125 +Q•4 3/8" 8046957 TEK 50 12-24 x 1-1/2"TEKS 5 3125(3/16") 1500 1475 .187"-3/16' 1/2" 25 125 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446(20 ga.) .188"-3/16" 1/4" 25 125 970(16 ga.) 1/2" 8033925 DSTR 1.0• 1/4-20 x 1"TEKS 3 1510(20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16' 5/16-18 x 1-1/4"TEKS 3 2220(20 ga.) .036"-20 ga 1/8" 25 125 1/2" 8035925 DST 5.16 5/16-18 x 1-1/4"TEKS 3 1500(3/16") .125"-1/8" 1/8" 25 125 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125(3/16") .187"-3/16" 1/2" 25 125 #14 SW Red Nut Driver 'Includes retaining nut Part#8114910 SAMMY Swivel Head® for Steel Installs VERTICALLY and swivels up to 17° in steel structure 1 Product Features • •Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hang plumb. •Accommodates 3-1/2 x 12 pitch. •Allows 17°deflection from vertical Rod Part Screw Ultimate UL Test FM Test Min Max Box Case Approvals Size Number Model Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty �' 3/8" 8137957 SH-DSTR 1• 1/4-20 x 1" 3220(3/161 1500 1475 .035' 3/16' 25 125 } 'Includes retaining nut (Does not campy with ROHS requirements) #14 Black " Nut Driver SPECIAL NUT DRIVER SYSTEM The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. • • SAMMYS HORIZONTAL MOUNT SIDEWINDERS® for Steel Malls HORIZONTALLY into the side of steel structures easily and quickly.! IP , N * 0 WO /8.10/110 rs ling •Made with Teks®self-drilling fasteners-no pre-drilling required. PCe required Product Features •Install into steel range from 22 gauge—12"thicknesses •Saves time from traditional methods •Reduces installation cost •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ib). ts) Thickness Thickness Qty Qty 1/4" 8047957 SWD100 1/4-14 x 1'TEKS 3 1477(16ga.) .060"-16 ga 3/16' 25 125 1/4" 8049957 SWDR 100' 1/4-20 x 1"TEKS 3 1900 (20 ga.) .036"-20 ga 3/16" 25 125 3/8' 8050957 SWD10 1/414x1-TEKS 3 1477(16ga.) .060"-16ga 3/16" 25 125 . 3/8" 8080925 SWD 10-SS 1/4-14 x 1"TEKS 3 1477 (16 ga.) 060"-16 ga 3/16" 25 125 3/8" 8051957 SWD 15 1/4-14 x 1-1/2"TEKS 3 1477(16 ga.) .060'-16 ga 3/16" 25 125 i _ 3/8" 8081925 SWD 15-SS 1/4-14x1-1/2"TEKS 3 1477 (16 ga.) 060"-16 ga 3/16" 25 125 3/8" 8052957 SWD 20 1/4-14x2"TEKS 3 1477(16 ga.) .060"-16 ga 3/16' 25 125 3/8" 8053957 SWD 516 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) 036"-20 ga 1/8" 25 125 #14 SW Red Q'4 3/8" 8055957 SWDR 1* 1/4-20 x 1'TEKS 3 1900(20 ga.) 1500 1475 .036'-20 ga 3/16" 25 125 Nut Driver Q-0 3/8" 8054957 SWDR 1-1/2' 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .187"-3/16" 1/2" 25 125 Part#8114910 Q-© 3/8" 8056957 SWDR 516' 5/16-18 x 1-1/4"TEKS 3 2480(20 ga.) 1500 1475 .036'-20 ga 1/8' 25 125 t,;, 3/8" 8057957 SWT 15 12-24 x 1-1/2"TEKS 5 237(3/16") .187"-3/16" 1/2" 25 125 'Includes retaining nut ti Performance Data - Steel Sheet Steel Gauges 1 I Gauge No. mm® 20 conm®erni Nominal Decimal Equivalent 018 024 030 .036 048 .060 .075 105 E 250 Ultimate Pullout Values(avg.lbs.ultimate)-SAMMYS E Aluminum Curtain Wall Extrusion Ultimata Pusout Yawn Fastener Steel Gauge(lbs.) Model Dia. Pt. 20 18 16 14 12 3/16 114 Fastener Thickness DST 1/4 #3 446 613 970 1145 1544 3190 Model Dia. 1:11E1 .092 ri® DST 516 5/16 #3 457 568 1209 1712 2422 DST 10 El El EIS. 2750 - TEK 50 #12 #5 487 699 913 1527 3270 3593 SWD 10 Ella. 1120 - 1420 - DSTR 1.1/2" #12 #5 3270 3593 M DSTR 1" 1/4 #3 1510 DSTR 516 5/16 #3 2200 'la ;P I. tValues(avg.lbs.ulti'" : . Fastener Steel Gauge(lbs.) Model Dia. Pt. 20 18 16 14 12 3/16 1/4 SWD 1/4 #3 1477 SWDR 1.1/2" #12 #5 2375 SWDR 1" 1/4 #3 1900 1900 SWDR 516 5/16 #3 2480 2480 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free,Installation is then complete Warranty requires the use of the appropriate nut driver for installations. 7 To find a distributor near you,call 800-BUILDEX Seismic Bracing • Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment ®TOLCO Size Range: 2" (50mm)through 8" (200mm)IPS. glill .. Material: Steel C US s Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA(UL)and �.• Canada(cUL)2" (50mm)through 8" (200mm)pipe. For FM Approval information refer to page 47. �% ?41Installation Instructions: Fig.4L is the "braced pipe" attachment . component of a longitudinal sway brace assembly. It is intended to be Set Bolt&Hardware Included LISTED combined with the "bracing pipe" and Cooper B-Line/TOLCO structural A attachment component to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig.4L over the pipe to be braced and tighten D bolts.Then engage "bracing pipe" into jaw opening and tighten set bolt until head snaps off.Jaw attachment can pivot for adjustment to proper brace angle. lk,NI lb.. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. • Order By: Figure number, pipe size and finish. C % QI1 ,w .411111".. Illf E.• Ilig ,. ao, 4-Way Riser Brace r„ (plan view) Longitudinal Brace Pipe Max.Rec.Load Approx. Part Size A C D Bolt Size (cULuc) Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 41-2 2" (50) 53/8" (136.5) 21/16 (52.4) 21/16" (52.4) 1/2"-13 2015 (8.96) 247 (112.0) 4L-21/2 21/2" (65) 67/16" (163.5) 21/2" (63.5) 23/4" (69.8) 1/2"-13 2015 (8.96) 253 (114.7) 41-3 3 (80) 7" (177.8) 23/4" (69.8) 31/16 (77.8) 1/2"-13 2015 (8.96) 268 (121.5) ,, 4L-4 El (100) 81/2" (215.9) 33/8' (85.7) 311/16" (93.7) 1/2"-13 2015 (8.96) 348 (157.8) \ 4L-5 5" (125) 93/4" (247.6) 31/s" (98.4) 43/8" (111.1) 1/2"-13 2015 (8.96) 380 (172.3) 41-6 6" (150) 111/2" (292.1) 5" (127.0) 51/8" (130.2) 1/2"-13 2015 (8.96) 640 (290.3) 41-8 8 (200) 131/4" (336.5) 55/8" (142.8) 55/8" (142.9) 1/2"-13 2015 (8.96) 728 (330.2) *The loads listed are axial loads on the brace.The horizontal load capacity, H,of the • brace is: H = F x sin ?, where?the installation angle measured from the vertical. • Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Seismic Bracing Fig.4L - Longitudinal "In-Line" Sway Brace Attachment ®TOLCO' Size Range: 21/2"(65mm)through 8"(200mm)IPS. Material: Steel APPROVED Function: For bracing pipe against sway and seismic disturbance. Set sops Hardware Inducted Approvals: Approved by Factory Mutual Engineering(FM), 21/2" (65mm) *I t through 8" (200mm)pipe. A_,,,..:,For UL Listed information refer to page 46. _'- ' Installation Instructions: Fig.4L is the"braced pipe"attachment component of a longitudinal sway brace assembly. It is intended to be A combined with the "bracing pipe"and Cooper B-Line/TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig.4L over the pipe to be braced and tighten D bolts.Then engage"bracing pipe" into jaw opening and tighten set bolt until head snaps off.Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. c Order By: Figure number,pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8. ril* Fr / •‘ . / ft .'411. , L ',..:;"''' ...,. .. \:. _ y/. r ..,z4 .:. Alk.. II E mi 4' it, 4-Way Riser Brace ly„ L .. (plan view) Longitudinal Brace Pipe *Max.Design Load(FM) Approx. Part Size A C D Bolt Size 300-44° 450-59° 60°44° 750-900 WtJ100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs. (kg) 4L-21/2 21/2" (65) 67/16" (163.5) 21/2" (63.5) 23/4" (69.8) 1/2"-13 1030(4.58) 1180(524) 1420(6.31) 1590(7.07) 253 (114.7) 41-3 3" (80) 7" (177.8) 23/4" (69.8) 31/16" (77.8) 1/2"-13 1030(4.58) 1180(5.24) 1420(&31) 1590(7.07) 268 (121.5) 41-4 4" (100) 81/2" (215.9) 33/8" (85.7) 311/16" (93.7) 1/2"-13 530(236) 730(3.25) 890(3.96) 990(4.40) 348 (157.8) • f 41-5 5" (125) 93/4" (247.6) 37/8" (98.4) 43/8" (111.1) 1/2"-13 530(2.36) 730(3.25) 890(3.96) 990(4.40) 380 (172.3) ". 41-6 6 (150) 111/2" (292.1) 5" (127.0) 51/8" (130.2) 1/2"-13 530(2.36) 730(3.25) 890(3.96) 990(4.40) 640 (290.3) 41-8 8" (200) 131/4" (336.5) 55/8" (142.8) 53/8" (142.9) 1/2"-13 490(2.18) 680(3.02) 830(3.69) 930(4.13) 728 (330.2) FM Approved when used with 1", 11/4", 11/2" or 2"Sch.40 brace pipe. FM Approved design loads are based on ASD design method. • Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. IIIMIIIMMICIIIMO1lMllIllIllIlWMIMMIa0 Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - 3/8" to 3/4" ®TOLCO- Size Range: One size fits bracing pipe 1" (25mm)thru 2" (50mm), Cooper C (0) US B-Line 12 gauge(2.6mm)channel, and all structural steel up to 1/4" (31.7mm)thick. LISTED Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment � � opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on 980 \� concentric loading. Mounts to any surface angle. Break off bolt head assures �1� verification of proper installation. ® 0 Installation: Fig.980 is the structural or transitional attachment component ' \, of a longitudinal or lateral sway brace assembly. It is intended to be combined A �� with the "bracing pipe" and Cooper B-Line/TOLCO "braced pipe" attachment, B Fig. 1000, 1001,2002,4L,4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. Set Bolt To Install: Place the Fig.980 onto the "bracing pipe".Tighten the set bolt until Included the head breaks off.Attachment can pivot for adjustment to proper brace angle. Mounting Hardware Is Not Included Approvals: —Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). For FM Approval information refer to page 61. , Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002,4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of k, ` Underwriters Laboratories and the National Fire Protection Association(NFPA) A Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. "'"° Pat. #6,273,372, Pat. #6,517,030, Pat.#6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat.#7,441,730, Pat. #7,669,806 Fig.980 Fig.4L 7� ® Lateral Brace I Longitudinal Brace ` Part Mtg.Hdw. Mounting Hole Max.Design Approx. ,4 Number Size A B D Load(cULus) Wt/100 • in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 980-3/8 Ei (9.5) 51/4" (133.3) 17/a" (47.6) 13/32" (10.3) 2765 (12.30) 133 (60.3) 980-1/2* ® (12.7) 51/4" (133.3) 17/8" (47.6) 17/32" (13.5) 2765 (12.30) 132 (59.7) 980-5/8 El (15.9) 51/4" (133.3) 17/8" (47.6) 11/16" (17.5) 2765 (12.30) 131 (59.4) • 980-3/4 El (19.0) 51/4" (133.3) 17/8" (47.6) 13/16" (20.5) 2765 (12.30) 130 (58.9) *Standard size. • Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 60