Report
Pfc c SL0 SA)v tdc€s L1 Sq M WYAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 SEE ' S CANDIES : WASHINGTON SQUARE 9585 SW WASHINGTON SQUARE ROAD #H-15 TIGARD, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL tI.ICa Worldwide Fire Protection Contacts www.tyco-fire.com Products • Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described ,� Description herein must be installed and maintained 1 of'�C.;.. in compliance with this document,as The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards - Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- 1 Sprinklers described in this data sheet tion,in addition to the standards of any 't' are standard response,standard cover- other authorities having jurisdiction. age,decorative 5 mm glass bulb type Failure to do so may impair the perfor- . spray sprinklers designed for use in mance of these devices. '-t4- light, ordinary, or extra hazard, corn- mercial occupancies such as banks, The owner is responsible for maintain- _ - hotels, shopping malls, factories, ing their fire protection system and — 4i { refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with Am TY-B Pendent Sprinkler, where appli- any questions. cable,is intended for use in areas with a I finished ceiling.This recessed pendent Sprinkler sprinkler uses one of the following: prinkler `' • A two-piece Style 15 Recessed Identification 'Jr . 4,I) Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from Numbers (SINs) - --. , the flush pendent position. • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT 3_ ment up to 1/2 inch (12,7 mm)from the flush pendent position. Technical The adjustment provided by the Temperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM, LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler: Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)° 'The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sealing Assembly Stainless Sheet TFP700 for the "INSTALLER Discharge Coefficient Steel w/TEFLON WARNING" that provides cau- K=5.6 GPM/psi1/2(80,6 LPM/bar��z) Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page 2 of 4 - Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* 1 6 :r;ri1�`r'\ iirirr_i—�_ -% = '— 7/16" ss 5 cl (11,1 mm) �� iuI c, 4 NOMINAL ell 2" 0� . MAKE-IN (50,8 mm) �-- 2 �• 2" 1-3/8' 3 ��, (50,8 mm) (34,9 mm) J `_J WRENCH I I FLATS 1 . 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE 41C..., Operation Installation WRENCH RECESS ...../1 The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to FIGURE 2 activate and water to flow. General Instructions Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubble is approximately 1/16 inch Upright(TY315)and Pendent(TY325) inc mm)for the 135 F (57°C)to 3/32 inch (2,4 mm) for the 360°F (182°C) Pit Sprinklers are intended for fire protec temperature ratings. tion systems designed in accordance 7n with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 S� is based on the requirements of NFPA ft.-Ibs. (9,5 to 19,0 Nm). Higher levels I..., 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- pendent AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3.Tighten the sprinkler into the sprinkler fitting using only the W-Type —2 ,0"DIA. — 6 Sprinkler Wrench (Figure 2). With (7733,o mm) reference to Figure 1,apply the W-Type 2-1/4"DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs. (9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i \ _ No FLUSH The Series TY-B Recessed Pendent 3/8±5/16" _1 Sprinklers must be installed in accor- (9,5±7,9 mm) 11�`L` 1' dance with the following instructions. } / , Step A.After installing the Style 15 or MOUNTING `�' 1/8" i Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm) over the sprinkler threads and with — pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into TY-B PLATE 3/4"(19,1 mm) the sprinkler fitting. FIGURE 4 Step B.Tighten the sprinkler into the SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) sprinkler fitting using only the W-Type WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER 2-1/4"DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" 1/2"(12,7 mm)TY-B Sprinkler and push the (7,9±6,4 mm) ( ) Closure over the Mounting Plate until + - FLUSH its flange contacts the ceiling. 7I)Care and f - MOUNTIN 1/8" i Maintenance SURFAC , (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion,but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav The owner must assure that the age to the sprinklers- before, during, ing jurisdiction. Contact the installing sprinklers are not used for hanging and after installation. Sprinklers dam- contractor or sprinkler manufacturer p g e aged by dropping, striking, wrench regarding any questions. any objects and that the sprinklers are only cleaned by means of gently dust—twist/slippage, or the like, must be Automatic sprinklers are recommended ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. NFPA 25 are required;however,instead of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page 4 of 4 P/N* 77 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010)"" 155 155°F(68°C) POLYESTER *Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-I 4 POLYESTER 175 175°F(79°C) 9 CHROME PLATED 200 200°F(93°C) **Eastern Hemisphere sales only 286 286°F(141°C) 360 360°F(182°C) 000 OPEN*** "`OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent (specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating, (specify)finish, P/N (specify, refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N (specify`) Specify:Style 20 Recessed Escutcheon with(specify")finish, P/N (specify") "Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. Vi co Protection Products CO Worldwide Contacts www.tyco-fire.com Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General stallation or finish. The tip of the Pro- tective Cap can be used to mark the Description center of the ceiling hole into plaster — p board or ceiling tiles by gently push- The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- j "Royal Flush II" Concealed Pendent tective Cap. When ceiling installation Sprinklers Quick Response (3 mm is complete, the Protective Cap is re- moved and the Cover Plate/Retainer bulb) and Standard Response (5-mm - bulb), are decorative sprinklers featur- Assembly is installed. ing a flat cover plate designed to con- As an option,the Series RFII Standard ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal. ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust • TY3531 (3-mm Bulb) is UL Listed, Each sprinkler includes a Cover Plate/ Seal is intended for sensitive areas C-UL Listed, Approved (Certif- Each irate No. G4090007),07), and NYC Ap- Retainer Assembly and a Sprinkler/ where it is desirable to prevent air and proved (MEA 353-01-E) as Quick Support Cup Assembly. The separa- dust from the area above the ceiling to Response. ) ble, two-piece assembly design pro- pass through the cover plate. vides the following benefits: • TY3531 (3-mm Bulb) is FM and NOTICE LPCB Approved (Ref. No. 094a/10) • Allows installation of the sprinklers Approved as Standard Response. and ressure testing of the fire pro- The Series RFII Concealed Pendent p g p Sprinklers described herein must be Factory Mutual and LPCB do not tection system prior to installation installed and maintained in compli approve any concealed sprinklers of a suspended ceiling or applica- ance with this document and with the cll for quick response. tion of the finish coating to a fixed applicable standards of the National • TY3551 (5-mm Bulb) is UL Listed, ceiling. Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and ceiling panels for access to building ties having jurisdiction. Failure to do so NYC Approved (MEA 353-01-E) as service equipment without having may impair the performance of these Standard Response. to first shut down the fire protection devices. Approvals for Air and Dust Seal system and remove sprinklers. The owner is responsible for maintain- • Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de- UL and C-UL Listed for use with the vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551). length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure sprinkler drops. with any questions. Maximum 250 psi (17,3 bar) by UL, The Series RFII Sprinklers are shipped C-UL,and NYC with a Disposable Protective Cap.The Sprinkler Protective Cap is temporarily removed Maximum 175 psi (12,1 bar) by FM, during installation and replaced to help Identification VdS,and LPCB protect the sprinkler during ceiling in- Temperature Rating Number (SIN) 155°F(68°C)Sprinkler with IMPORTANT TY3531 — 3 mm bulb 139°F(59°C)Plate Always refer to Technical Data Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200°F(93°C)Sprinkler with WARNING" that provides cautions 165°F(74°C)Plate with respect to handling and instal- Technical Discharge Coefficient lation of sprinkler systems and com- ponents. Improper handling and in- Data K.5.6 GPM/psi (80,6 LPM/bar ) stallation can permanently damage Adjustment a sprinkler system or its components Sprinkler Approvals 1/2 inch(12,7 mm) and cause the sprinkler to fail to Approvals apply only to the service operate in a fire situation or cause it conditions indicated in the Design Cri- to Finishes operate prematurely. teria section. See the Ordering Procedure section. Page 1 of 4 MARCH 2013 TFP181 TFP181 Page 2 of 4 Physical Characteristics 1/2"NPT Ir, SEALING Frame Bronze , ASSEMBLY Support Cup Chrome Plated Steel !__________.______.---------- Guide Pins Stainless Steel FRAME �j�Deflector Bronze , '- CAP Compression Screw Brass / i • 4 i Bulb Glass �� Cap Bronze or Copper SUPPORT Sealing Assembly Beryllium Nickel w/TEFLON CUP WITH I BULB Cover Plate Brass ROLL FORMED Retainer Brass THREADS Ejection Spring Stainless Steel — R Design I I I COMPRESSION GUIDE - }� SCREW Criteria PINS(2) n Fp The TYCO Series RFII 5.6 K-factor, _ DEFLECTOR "Royal Flush II" Concealed Pendent — I (DROPPED Sprinklers are intended for fire protec- DEFLECTOR i c=--,:'_'-., J-L--3� POSITION) tion systems designed in accordance r with the standard installation rules rec- ognized by the applicable Listing or I SPRINKLER/SUPPORT CUP Approval agency;for example,UL List- ASSEMBLY ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. THREAD INTO II RETAINER SUPPORT J I WITH THREAD For more information on LPCB and CUP UNTIL . 0 0 DIMPLES VdS Approvals, contact Tyco Fire Pro- MOUNTING tection Products at the following office: SURFACE IS EJECTION Enschede,Netherlands FLUSH WITH SPRING Telephone:31-53-428-4444 CEILING Fax: 31-53-428-3377 The Series RFII Concealed Pendent J L '---- a Sprinklers are only listed and approved rr with the Series RFII Concealed Cover / Plates having a factory applied finish. SOLDER J COVER TABS(3) COVER PLATE/RETAINER PLATE NOTICE ASSEMBLY Do not use the Series RFII in applica- FIGURE 1 tions where the air pressure above MODEL RFII CONCEALED SPRINKLER the ceiling is greater than that be- ASSEMBLY low. Down drafts through the Sprin- kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in- sprinkler operation in a fire situation. sufficient adjustment in the Sprinkler The TYCO Series RFII 5.6 K-factor, by under- or over-tightening the Sprin- OperaO tion "Royal Flush II" Concealed Pendent kler/Support Cup Assembly. Re-adjust pSprinklers must be installed in accor- the position of the sprinkler fitting to When exposed to heat from a fire, the dance with this section. suit. Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the Retainer at three points, falls away to pendent position with the center-line expose the Sprinkler/Support Cup Do not install any bulb-type sprinkler if o.f the sprinkler perpendicular to the Assembly. the bulb is cracked or there is a loss mounting surface. of liquid from the bulb.With the sprin- Step 2. Remove the Protective Cap. The Deflector — supported by the kler held horizontally, a small air bub- Guide 3. With pipe t sealant ap- operational Pins — then drops down to its ble should be present. The diameter Step 3. the pipe pipe thread h ea, hand-tighten position. of the air bubble is approximately 1/16 the sprinkler into the sprinkler fitting. - The glass bulb contains a fluid that ex- inch (1,6 mm)for the 155°F(68°C)and pands when exposed to heat. When 3/32 inch(2,4 mm)for the 200°F(93°C) Step 4. Wrench-tighten the sprinkler temperature ratings. using only the RFII Sprinkler Wrench. the rated temperature is reached, the (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as glass bulb, activating the sprinkler and should be obtained by applying a min- shown in Figure 3. allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap ft.-Ibs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms of torque can distort the sprinkler In- out against the Support Cup. (Refer let with consequent leakage or impair- to Figure 4.)The Protective Cap helps ment of the sprinkler. prevent damage to the Deflector and TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER - DIAMETER HOLE FITTING DIMENSION C J . SPRINKLER =� SUPPORT CUP 1iiii ASSEMBLY I 1/2"(12,7 mm) 1 - THREADED D ADJUSTMENT 1j AI ,���, �i FACE / 1.11 OF CEILING, )' RETAINING RING \ MOUNTING /7 l , / SURFACE II \ FIGURE 4 II DISPOSABLE PROTECTIVE CAP , ‘.\--; _ i i Arms during ceiling installation and/or finish.You can also use the Protective c -'-r-� Cap to locate the center of the clear- 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE ance hole by gently pushing the ceiling (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY the Protective Cap. COVER PLATE COVER PLATE NOTICE -PROFILE DEPTH DIAMETER As long as the Protective Cap remains DIMENSION B DIMENSION A in place, the system is considered A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service" Step 6.After the ceiling has been com- B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) pleted with the 2-1/2 inch(63,5 mm)di- ameter clearance hole and in prepa- FIGURE 2 ration for installing the Cover Plate/ SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis- card the Protective Cap.Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the VAIllitt FRAME ij=i, Deflector does not move up and down ARM % �_ % ' freely, replace the entire Sprinkler. II111 / Do not attempt to modify or repair a damaged sprinkler. SUPPORT Step 7. When installing an Air and CUP I - I Dust Seal, refer to Figure 5;otherwise, i proceed to Step 8. To attach the Air i and Dust Seal, verify the angle of the •'•' i�,!•"�� I■I outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of --- — —- 0 the Retainer in the grooved slot of the 7/8"(23 mm) Air and Dust Seal and continue around SQUARE the retainer until the entire Air and Dust / Seal is engaged. / Step 8. Screw on the Cover Plate/ ALIGN / L.. Retainer Assembly until the Retainer ARROWS WITH i 1 i (shown in Figure 2)or the Air and Dust FRAME ARMS \_ Seal (shown in Figure 5) contacts the l r ceiling. Do not continue to screw on i i the Cover Plate/Retainer Assembly ACCEPTS `�,_r�� so that it lifts a ceiling panel out of its 0 1/2"SOCKET \\ normal position. If you cannot engage - DRIVE — the Cover Plate/Retainer Assembly FIGURE 3 with the Support Cup or you cannot As- RFII SPRINKLER WRENCH engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Care and SUPPORT — _ SPRINKLER FACE OF ORIENT CUP CEILING ��SEAL Maintenance BEVEL AS l�l__ j� SHOWN The TYCO Series RFII 5.6 K fac COVER - tor, "Royal Flush II" Concealed Pen- 1 PLATE _ RETAINER dent Sprinklers must be maintained 1 ASSEMBLY and serviced in accordance with this 1 section. _ _ . : ) Before closing a fire protection system `j ' - I �� AIR main control valve for maintenance �►.' work on the fire protection system that / ,� „■" 1��� �� AND DUST■it controls, obtain permission to shut ,=---ICI--- ` SEAL p �� LIP OF COVER down the affected fire protection sys- RETAINER PLATE tern from the proper authorities and FIGURE 5 notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) ed by this action. Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Ordering Assembly can delay sprinkler opera- reinstall it or a replacement without re- tion in a fire situation. installing the Cover Plate/Retainer As- Procedure When properly installed, there is a As- sembly. If a Cover Plate/Retainer As /� Y nominal 3/32 inch (2,4 mm)air gap be- sembly becomes dislodged during Contact your local distributor for tween the lip of the Cover Plate and the service, replace it immediately. availability. When placing an order, ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the full product name. This air gap is necessary for proper their f fire testing, and maintenance of Sprinkler/Support Cup Assembly operation of the sprinkler. If the ceil- their fire protection system and devic- op requires a ion of repainting er. f sprinkler es in compliance with this document, Specify: Series RFII (specify SIN), installation, ensure that after new paint as well as with the applicable stan- K=5.6, "Royal Flush II" Pendent Sprin- installation, not seal off any a the air gap. dards of the National Fire Protection klers (specify) temperature rating and Association(e.g.,NFPA 25), in addition (specify)finish, P/N(specify). Do not pull the Cover Plate relative to to the standards of any other authori- the Enclosure.Separation may result. ties having jurisdiction.Contact the in- 155°F(68°C) 200°F(93°C1 Sprinklers which are found to be leak- stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200 p facturer regarding any questions. TY3551 51-790-1-155 51-790-1-200 ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/ inspected,tested,and maintained by a Retainer Assembly: Automatic sprinklers must never be qualified Inspection Service in accor- painted, plated, coated, or other- dance with local requirements and/or Specify: (temperature rating from be- wise altered after leaving the factory. national code. low) Series RFII Concealed Cover Modified sprinklers must be replaced. Plate with(finish), P/N(specify). Sprinklers that have been exposed to 139°F(59°C)(a) 165°F(74°C)(b) corrosive products of combustion, but Grey White have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165 if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165 by wiping the sprinkler with a cloth or Pure White(c) by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165 Care must be exercised to avoid dam- Signal white (RAL9003) 56-792-4-135 56-792-4-165 age to the sprinklers - before, during, Jet Black and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165 aged by dropping, striking, wrench Brushed twist/slippage, or the like, must be re- Chrome 56-792-8-135 56-792-8-165 placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165 has a cracked bulb or that has lost Custom 56-792-X-135 56-792-X-165 liquid from its bulb. (Ref. Installation (a) For use with 155°F(68°C)sprinklers. Section.) (b) For use with 200°F(93°C)sprinklers. Exercise care to avoid damage to (c) Eastern Hemisphere sales only. sprinklers before, during, and after in- Sprinkler Wrench stallation.Replace sprinklers damaged • by dropping, striking, wrench twisting, Specify:RFII Sprinkler Wrench, P/N 56-000-1-075. wrench slipping, or the like. Also, re- place any sprinkler that has a cracked Air and Dust Seal bulb or that has lost liquid from its bulb.(Refer to the Installation section.) Specify:Air and Dust Seal, P/N 56-908-1-001. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. t co TEFLON is trademark of The DuPont Corporation. y Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1 .0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE (in) '' HT(lbs/ft) I.D. ' BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS �� •!- ►..�.:�� ®l��i!�' . "� r_1'µ._._! ' '! 1 1.00 1.00 1 1/4 1.00 1.00 • 1 1/2 1.00 1.00 2 1.00 1.00 Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems ,. (N 1819 Clarkson Road For additional information, C 0 us Chesterfield,MO 63017 contact your salesperson today at BULL MOOSE TUBE COMPANY 8 (800)325-4467 (800)325-4467 or(636)537-2600 LISTED FAX:FAX:(636)537-2645 in the USA,or from Canada www.h.btiul lmoosetu tube.com call(800)882-4666 41> A LARD company e-mail:sales a bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 • SC1 Ductile Iron Fittings- Class 300 UL/FM I QLL LrTY PWS • c ® us APPROVED Fig. 35E 3-90°Elbow LISTED A Size A Packing Weight • wh....,„,ii in Part Number in Inner Master lb __ \ 1/2 35E 3004 1.13 100 200 0.2 ' 3/4 35E 3006 1.31 70 140 0.3 i �i ' A 1 35E 3010 1.50 40 80 0.5 ��l 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B Size A B Packing Weight ice; in Part Number in in Inner Master lb \ 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 IS A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 ��q! 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 -Cl 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 ° C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 T / Fig. 35F 3-45°Elbow Size Part Number A Packing Weight F ' A in in Inner Master lb /11\ 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 � 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 35F 3014 I��� .,A 1 2/2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 -• 8 2.7 • Fig. 35T 3- Tee Size A Packing Weight : al Part Number in in Inner Master- 160 .j__ _ TEE�IA 1/2 35T 3004 1.13 80 160 0 3 3/4 35T 3006 1.31 30 60 0.5 I �I 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 < A ��� A 1-1/2 35T 3014 1.94 10 20 1 5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com , . ut '- Ductile Iron Fittings- Class 300 UL/FM I QUALITY PLUS t -- c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size part Number A Packing Weight . °' in in Inner Master lb _ . 35CP3004 1 3H 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 s. 1 35CP3010 175 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight N in in Inner Master Ib ® IA 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 0.6 1-1/4 x 3/4 35RC3012006 2.06 40 80 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing II i Size part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 III A 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 i 1-1/2 x 1 35HB3014010 125 75 150 0.4 1-1/2x 1-1/4 35HB3014012 1.25 75 150 0.3 k-.. .l) 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packing Weight in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 8 A 3/4 35SP3006 1.12 350 700 0.1 Mk 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 _ 45 90 0.6 Fig. 35U 3-Union with Brass Seat - A Size A Packing Weight Part Number in Inner Master lb �... 1 35U 3010 2.19 20 40 1.0 -191111k 0 1-1/4 35U 3012 2.50 15 30 1.2 3..;, 1-1/2 35U 3014 2.62 10 20 1.7 '� � 2 _ 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • "POLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Pipe Hangers . Fig.200- "Trimline" Adjustable Band Hanger (B-Line Fig.B3170NF) ®TOLCO . Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) c CL us Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) USTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut ' Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications y Function: For fire sprinkler and other general piping purposes. Knurled - . u swivel nut design permits hanger adjustment after installation. Features: m • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe 4`�'► /� �f' ',i types and protect CPVC plastic pipe from abrasion. Captured design C-'� keeps adjusting nut from separating with hanger. Hanger is easily ;' B fr installed around pipe. A For hanger with non-captured nut order Fig.200S. • (21/2" (65mm)thru 8" (200mm))Spring tension on nut holds it securely in / k ��- hanger before installation.Adjusting nut is easily removed. ' /I Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) f` s Fig.200-1/z.200-3/4 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.2001to2002 Fig.20O21/zto200.8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) -a- Finish: Pre-Galvanized. Stainless Steel ar materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of i FM DS 2-0. 4 & Fig.200 d Fig. Fig.200F ig.200C w Pipe Size Rod Size A B Approx.WtJ100 .4, Part No. in. (mm) in. Imm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8'-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4" 132) 3/8"-16 33/4" (94.01 21/8' (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/e"-16 37/8" (98.4) 27/8" 173.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.31 15 (6.91 4 200-21/2 21/2' (65) 3/e"-16 55/e" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/e"-16 57/8" (149.1) 4" (101.61 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.31 34 (15.6) ' 200-4 4" (100) 3/8'-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" 1158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 80 (2001 1/2"-13 131/8" (333.4) 83/4" 1222.21 136 (623) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. p Fire Protection Solutions B-Line 21 by E:T•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) ,� , B3205L - Threaded Rod (right& left hand threads) / TL Size Range: 3/8"-16 thru 3"-4 rod Specify Length • 1 Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Ti. , Rod is threaded on both ends with right hand threads of the length shown.Also \�11\l�h A available with left and right hand threads-specify Fig. B3205L when ordering. Thread Sae Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/e"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/e x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 83205-1 x'L' 1"-8 4" (101.6) 5900 _ (26.24) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) _ 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33,09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 _ (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 - All Threaded Rod Cut To Length � � i∎ a°11��11113 Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length sin),,,,,l��i Material: Steel V'" N V CO Maximum Temperature: 750°F(399°C) o `o Finish: Plain.Contact B-Line for alternative finishes and materials. d d r u Order By: Part number, rod diameter and finish a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/e"x length 16 730 (3.24) 29 (13.15) _ ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"x 120 99-7/a"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 236 Revised 4/28/2014 by E_T•N SAMMY X-PRESS® SAMMYSJ '. s`;= Sammy X Press® Installs into Metal Deck. Purlin. or Tubular Steel r0\ it //°��' , Product Features r.7 Ii' r •The Sammy X-Press expands to provide •Installs in seconds,saving time& (XP) II direct vertical attachment in: installation costs. I . Patent No.6,935,821 -Metal Deck(22-16 gauge) -Z-Purlin(18-16 gauge) •Use in applications where access • A to the back of the installed fastener is •The Sammy X-Press Swivel allows you prohibited.ie.metal roof deck,tubular /1 to hang plumb in extreme roof pitches: steel,or vapor barrier fabric. (SWXP) -89°in in metal 45°in metal deck for 12/12 pitch •Less jobsite material needed. Patent Pending for to The Sammy X-Press Sidewinder expands •No retaining nut required. (SXP) extreme to provide horizontal attachment in: -16 ga-3/16'steel-puffin,tubular •Provides design flexibility. °f steel. Patent Pending variant roof Pitches I; Approvals Rod Part Y timate UL Test FM Test Min Max Box Case Model Descripti Application,ilYetbpr,: _-- ,.-4 Lo (Ibs) a LWti Ls) Thick Thick ay VERTICAL MOUNT Q. 1/4" 8181922 XP 200 X-Press 200 1146(22ga) 185(Luminare) 250(Luminare) 027" .056' 125" 25 125 Metal Deck 850(2'/,"Pipe) 940(2'Pipe) .027" 185(Luminaire) Q.- . 3/8' 8150922 XP 20 X-Press 20 1146(22 ga) 1475(4'Pipe) 027" 125" 25 125 Metal Deck .'5 q.. 250(Luminare) 056' �). , 283(Conduit&Cable) 1500(4'Pipe) .060' 85(Luminare) 940 (2'Pipe) 105' r 4 p., Q.0 3r8' 8153922 XP 35 X-Press 35 1783(16 ga) .125' 25 125 Purlin S 250(Luminaire) 1475(4'Pipe) .027' 4i 416(Conduit&Cable) 056- 750(2'Pipe) P) 1061(22 ga Ve tics) 170 vertical(Luminaire) .Q.' 3/8' 8294922 SXP 20 Swivel X-Press 20 829(45°OR Vertical) 80 @ 45•(Luminaire) 635(2'Pipe) .027' .125' 25 125 Metal Deck 283 vertical(Conduit&Cable) 233 @ 45•(Conduit&Cable) ffi 1500(4'Pipe) 1675(16 ga Vertical) 250 vertical(Lunt nave) Q-0 3/8' 8295922 SXP 35 Swivel X-Press 35 1558(89.Off Vertical) 80 @ 90•(Luminaire) 635(2'Pipe) 060- 125' 25 125 Purlin 500 vertical(Conduit&Cable) 333 @ 89°(Conduit&Cable) Pre-Pour Structural Concrete@ 3000 psi Metal Deck — Q 3/8' 8150922 XP 20 Sammy X-Press 20 1146(22 ga) 850(2''/Pipe) 25 125 (Pre-Pour) Post-Pour Range II LWCs 35 PCF(lbs./IN) Metz)Deck (Past-Pour) — t HORIZONTAL MOUNT 1250(3W Pipe) Q 3/8' 8293957 SWXP 35 Sidewinder X-Press 35 1798(16 ga) 80(Luminaire) 060' 125' 25 125 Purlin 416(Conduit&Cable) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(lbsl It') :ark, �_.. - _ t..r. . 0 ...r\----r\— --ritr\— -; :: 7 -`:-.:. J s ;". Sammy X Press It® INSTALLATION TOOL wit UXPIT ��• { Patent ,� 81. 949 0 UXPIT' Universal X-Press It Tool 1 s 1 w• 8195910 RXPIT Retro Socket for 8151910 1 8152910 XPDB 25/64'Drill Bt 1 To watch a video demonslrafon of the Sammy X-Press,visit http:/Mww.sammysuperscrewcom/sammyxpress.hbn _ 'Tool Includes.Sleeve.Bit Receiver,Hex Wrench.and 25/64'Drill Bit For the most up to date information,visit www.sammysuperscrew.com 8 ``?p// HS - ,. 1- A •/