Permit q CITY OF TIGARD MASTER PERMIT Ill E ' COMMUNITY DEVELOPMENT Permit#: MST2015-00170 T IGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/01/2015 Parcel: 1 S133DA04800 Jurisdiction: Tigard Site address: 12630 SW GLACIER LILY CIR Subdivision: AMART SUMMER LAKE Lot: 70 Project: KOEPKE Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $0.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio 8 Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other N Other Description: Ecompasing N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: KOEPKE,BRUCE B&JANET G SOLARCITY CORPORATION Required Items and Reports(Conditions) 12630 SW GLACIER LILY CIR 6132 NE 112TH AVE TIGARD,OR 97223 PORTLAND,OR 97220 PHONE: PHONE: 503-894-6903 FAX: 866-445-7459 Total Fees: $366.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through•,-.:52-001-0090. You may ob.•• •• - rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. rlaillb ' 1 Issued By: .i�s� ..•■• •- • ittee Signature: ' i , _�_ Call.' !'.41 5 by 7:00 a.m.for the next available Inspection date. This permit card shall b,Rep in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 0 ! Building Permit Application Residential GE��ED l Uit (,, i II I l •,i 4)\1 4 City of Tigard RE 2015 r �' Permit Na: ©(tj ( ,i 13125 SW Hall Blvd.,Tigard,OR 97223 CC P ti p Plan R ' .1 lr1ri Phone: 503.718.2439 Fax: 503.598.1961iv7�1 p Dwe/i : off��f�, Permit Inspection Line: 503.639.4175 �F T,3P Date Ready/By. 0 Sec Page 2 fee Internet: www.n rd-or. v G O 1 • : r ga 8o CO w1S`O r.t� �j1 Supplemental Iwtartwwtlaw TV'S OF ' :.' ?Ati- `Y ❑New construction ❑Demolition Permit fees'are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the T T ' L work indicated on this application.CAO O E ! C Valuation: S 6000 ®1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: 0 Master builder ❑Other: Number of bathrooms: N'1 TION , LOCATION Total number of floors: Job site address: 12630 SW Glacier Lily Cir, New dwelling area: square feet City/State/ZIP: TIGARD OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: 1 Project name: Koepke, Bruce B. Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet INIQWNW 1t irrAr ' • Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,Tabor,overhead,and the profit for the 'ossaw apt OV WORK work indicated on this application. Valuation: $ PV ROOF MOUNT Existing building area: square feet New building area: square feet , IIKRINITT OW J 13 taktirr Number of stories: Name: Koepke, Bruce B. Type of construction: Address: 12630 SW Glacier Lily Cir, Occupancy groups: City/State/ZIP: TIGARD OR 97223 Existing: Phone:( ) 503 524 7432 Fax:( ) New: gi:A1'P ICA' T' Business name: SolarCit Corp Y Structural plan review fee(or deposit): Contact name: Melissa Farias FLS plan review fee(if applicable): Address: 6132 NE 112th Ave. Total fees due upon application: City/State/ZIP: Portland OR 97220 Amount received: Phone'(503)894-6903 1 Fax::(1868 445-7459 I',° ; , ate E-mail:Melissa.Farias @SolarCitr.com °° � � x Commercial and residential ,�..�, .. . -�� .._ m _., prescriptive installation of -, roof-top mounted PhotoVoltaic Solar Panel System. Business name:SolarCity Corp. Submit two(2)sets of roof plan with connection details and Address: 613 2 NE 112th Ave /aster l department access,along with the 2010 Oregon Specralry Code checklist. City/State/ZIP: Permit Fee(includes plan review Portland OR 97220 and administrative fees): 5180.00 Phone:( 503) 894-6903 I Fax:(1866 445-7459 Statesurcharge(12%ofpermit fee): $21.60 CCB lic.: 1_80498 • Total fee due upon application: $201.60 Authorized signature: A •+. irk / This permit application expires if a permit is not obtained r within 180 days after it has been accepted as complete. I Print name: Melissa Fail il Data 9.21.15 •Fee methodology set by Tri-County Building Industry Service Baud. 1:1Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440.4613T(I 1/02/COM/WEB) • Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received ■ 13125 SW Hall Blvd..Tigard,OR 97223 - Phone: 503.718.2439 Fax: 503.598.1960 Associated permits: 1 uC;kitD 24-Hour Inspection Line: 503.639.4175 O cicc[rical ❑ flutabiug ❑ Mcrhanicul Internet: www,tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW '.'es No N/A I Land use actions completed. Sec jurisdiction criteria for concurrent reviews. • I • 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ■ 3 Verification of approved plat/lot. ❑ j I< 4 Fire district approval required. Name of district: ❑ j S 5 Septic system permit or authorization for remodel. Existinksystem capacity 0 • • 6 Sewer permit ❑ S 7 Water district approval. 0 • i• 8 Soils re ort. Must ca oriinal a. licablc st . and signature on file or with a..lication. • II ill 9 Erosion control 0 plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ • IN basin protection,etc. 10 3 Complete sets of legible plans. Must be drown to scale,showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if cops'riRht violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if El ❑ ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-It.intervals);location ofcasotnents and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage ofcoverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor pians. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 Cl furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sins and spacing such as floor beams,headers,joists,sub- ❑ ❑ 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is.grcatcr than four foot at building envelope. Full-size shed addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive patch)and/or lateral analysis plans, Must indicate details and locations;for non- ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering.standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member si zing,spacing,and bearing 0 0 ❑ locations. Shaw attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems,sec item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. 21 Energy Code compliance. identify the prescriptive path or provide calculations. A gas-piping schematic is required for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Ore on and shall be shown to be a livable to the. .'ea under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required f o r Item 11 above. Site plans must be 8-1/2"x 1 1"or I 1"x 17". 1-M• ■ 24 Two(2)sets each arc required for Items 16. 19,20 and 22 above. BEEN • 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. • • • 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ■ ■ 27 "Drawn to scale"indicates standard architect or engineer scale. • 28 Site plan to include tree size,typo and location per approved project street tree plan(if applicable),and City of Tigard ❑ • El Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, El ❑ ❑ t and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9,_1995. I:Ulnitd ngtPermias\RUP-RESPrnnitArp_doe 02/24/2011 440.4613T(I 1102/COM/WEB) f 1 Electrical Permit Application FOR oi•i ILF 1 SF ON1.1 City of Tigard EcE e ��� Permit No.:r�sTov2x 5-__ :I "t 13125 SW Hall Blvd.,Tigard,OR 205 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 1 I atc/By: Other Permit: I I I. K t? Inspection Line: 503.639.4175 Date e Ready/By: J.ris: l 0 Sec Page 2 for Internet: www.tigard-or.gov ^�. Notified/Method: —c> 11 Supplemental Information TYPE OF wrIY OG©Ivo$1O— PLAN REVIEW ❑New construction ®Addilion/alte0ment Please check at that apply(submit 2 sets of plans w!itcros checked below): ❑Service or feeder 400 amps or nwre ❑Building over three 51011cs. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONST'RUCT'ION exceeds 10,000 amps at 150 volts or ❑Floating buildings. — less to ground,or exceeds 14,000 ❑Commercial-use agricultural ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Multi-ramily ❑Master builder ❑Other: ❑fire pump. ❑Installation of 150 KVA or ❑Emergency system. larger separately derived system. JOB SITE INFORMATION AND LOCATION El Addition of new motor load of ❑'A "E","t-2","i-3", Job no.: 9723010 Job site address: 12630 SW Glacier Lily Cir, IOOHPormore. occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZiP: TIGARD OR 97223 ❑Health-care facilities. ❑Supply voltage for more than ❑Hazardoas locations. 600 volts nominal. Suite/bldg./apt.no.: Project name: Koepke, Bruce B. 0 Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: uperawion -- "" i Qiy. I Fee. i T.1e1 I • New residential single-or multi-family dwelling unit. Includes attached garage. q•ft.or less 168,54 1 4 1,000 s Subdivision: 1 Lot no.: Fa.add'!500 sq.ft.or portion 33.92 1 Tax map/parcel nn.: Limited energy,residential DESCRIPTION OF WORK (with above sq.ft.) 75'00 2 _ — Limited energy,multi-family 75.00 2 PV ROOF MOUNT residential(with above sq.It.) Renewable Energy ® See Page 2 Services or feeders installation,alteratlon,and/or relocation i®" PROPERTY OWNER ❑ TENANT 200 amps or less 100.70 2 201 amps to 400 amps 133.56 2 Name: Koepke, Bruce B. 401 amps to 600 amps 200.34 2 Address: 12630 SW Glacier Lily Cir, 601 amps to 1.000 amps 301.04 2 TIGARD OR 97223 Over 1,000 amps or volts 552.26 2 City/State/ZIP: Temporary services or feeders installation,alteration,and/or Phone:( 503) 524 7432 Fax:( ) relocation 200 amps or less 59.36 I Owner installation:This installation is being made on property that i own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits-new alteration,ur extension,per panel lgi APPLICANT I.... ® CONTACT PERSON A.Fix for branch circuits with above service or feeder fee. 7 4) 2 Business name:SOIarCity COrp. each branch circuit B.Fee for branch circuits without Contact name: Melissa Farias service or feeder fcc,first 56.18 2 branch circuit Address: 6132 NE 112th Ave Each add'I branch circuit i 7.42 2 City/State/ZIP: Miscellaneous(service or feeder not included) Portland, OR 97220 Each mattufacturrtil or modular 67.84 2 Phone:(503 ) 894-6903 Fax. :(1866) 445-7459 dwelling,service and/or feeder Reconnect only 67.84 2 E-mail: Melissa.Farias @SolarCity.com Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name: Signal circuits)or limited-energy See SolarCity Corp. panel,alteration,or extension. Paget 2 Address: Each additional inspection over allowable in any of the above 6132 NE 112th Ave -------- —' Additional inspection(I hr min) 66.25/hr City/State/ZIP: Portlari d.Q,R 97220 Investigation hr min) 66.25/hr Phone:(503) 894-6903 I Fax:(1866) 445-7459 lndttstnal plant(1 hr min) 78.18/hr Inspections for which no fee is 9000'hr CCB Lic.: 180498 Electrical Lic.: C562 Suprv.Lie.: 5873S specifically listed(,In tinn) ELECTRICAL PERMII FEES Suprv.Electrician signature,required:k' "�..w---„r..---•-" Subtotal —^ Print name: Nicholas Armstrong Date: 9/21/15 Plan review(25%of permit fee): State surcharge(12a/of permit fee): Authorized signature: c/ -•- , S TOTAL PERMIT FEE: t 'Phis permit application expires if a permit is not obtained within 180 Print name: Melissa Faria ` t Date: 9/21/15 days after it has been accepted as complete. • Number of inspections allowed per permit. 1..\3mklingiPermts\ELC_PermitApp_ELR_ERE.doc Rev 0521/2013 410.46157(11/051COMiWE13 Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDiENTIA WORK ONLY; Fee for all residential systems combined $75.00 Desteipthea Qt.. I Pee I Tart 1 • Renewable electrical energy systems: Check Type of Work Involved: s kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* I5.01 to 25 kva 200.34 2 H Burglar Alarm Wind generation systems in excess of 25 km 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 >100 kva(fee in accordance with 552.26 2 ❑ Heating,Ventilation and Air Conditioning OAR 91 8-309-0040) System* Solar generation systems In excess of 25 kva; Each additional kva over 25 7.42 3 fJ Vacuum Systems* >100 kva-no additional charge 0.0 3 ❑ Each additional inspection over allowable in any of the above_: Other: rich additional inspection is charged at an hourly(1 hr min) 66•25/lu I Inspections for which no fee is 90AOr hr spcctficaliy latest('h hr min) COMMERCIAL WORK ONLY: :04.s rit10 rElOgf i s Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if requires!(25%ofpermit fee): Slade surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT PEE: 111 Audio permit application expires if a permit is not obtained within 180 Audio and Stereo Systems days after it has been accepted as complete. " Number of instructions al owed per penTun, ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm installation ❑ HVAC ❑ Instrumentation El Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical n Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:V3uildeterermeeTI.C,ecraarApp CI.1t f:RE.doe Ree U6r2 I 201 City of Tigard Building Division RECEIVED _ 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 SEP 2 2.2015 TIGARD Inspection Line: 503.639.4175 CITY OF TIGARD www.tigard-or.gov BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12630 SW Glacier Lily Cir, TIGARD OR 97223 City: Zip: Owner's Name: Koepke, Bruce B. Date: 09/21/15 Contractor's Name: SOLAR CITY CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation El qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure ® Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:/B u i l di ng/Forms/Photovoltaic-Check l i st.docx Is the construction material wood and does Yes Type of the construction qualify If"Yes", qualifies for Construction "conventional light ❑ No the prescriptive path. as frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ® If"Yes",qualifies for Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or n No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of Li No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max.two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Bui lding/Forms/Photo V oltaic-Checkl ist.docx Is the gauge 26 or less? Yes If"Yes", qualifies for No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. n No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ❑ Yes If"Yes",qualifies for fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 (:Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and,as applicable,flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Model Number: 260 Listing Agency: UL1703 4 I:Building/Forms/PhotoVoltaic-Checklist.docx Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12630 SW GLACIER LILY CIR, TIGARD, OR, 97223 Residential - Master Permit 199 Electrical final PASS MST2015-00170 Jeff Grove Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12630 SW GLACIER LILY CIR, TIGARD, OR, 97223 Residential - Master Permit 299 Final inspection PASS - No C of O MST2015-00170 Jeff Grove Violation Summary: Inspector Contractor