Plans Aug 27 15 03:07p Honke Heating 503-666-0589 p.2 X10 lt�C. czude; `fIDO 5uw-F ups RA- w Ue "I • t.• Aug 27 15 03:07p Honke Heating 503-666-0589 p.3 i SPECIFICATIONS General Model No. 13ACX-018 13ACX-024 13ACX-030 13ACX-036 13ACX-042 13ACX-048 13ACX-060 Data Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Connections Liquid line o.d.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line o.d.-in. 5/8 5/8 3/4 3/4 3/4 7/8 7/8 'Refrigerant(R-410A)furnished 3 lbs.15 oz.3 lbs.15 oz. 5 lbs.2 oz. 5 lbs.4 oz. 6 lbs.8 oz. 7 lbs. 12 oz. 9 lbs.0 oz. RFCIV Metering Orifice Size 0.051 0.057 0.065 0.072 0.076 r 0.082 0.090 Outdoor Net face area Outer coil 11.33 11.33 13.22 13.22 16.33 18.67 16.33 Coil sq.ft. Inner coil --- --- --- --- --- --- 15.71 Tube diameter-in.I 5116 5/16 5/16 5/16 5/16 5/16 5/16 Number of rows 1 1 1 1 1 1 2 Fns per inch 26 26 26 26 26 26 22 Outdoor Diameter-in. 18 18 18 18 22 22 22 Fan Number of blades 3 3 4 4 4 4 4 Motor hp 1/10 1/10 115 1/5 1/4 1/4 114 Cfm 2350 2350 2400 2400 3500 3670 3600 Rpm 1010 1010 1090 1090 825 835 830 Watts 165 165 185 185 300 295 _ 285 Shipping Data-lbs.1 package 138 138 144 151 188 195 218 ELECTRICAL DATA Line voltage data-60 hz-1ph 208/230V 208/230V 208/230V 2081230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection(amps) 20 30 30 35 45 50 60 3 Minimum circuit ampacity 12.0 17.6 18.7 22.0 28.1 31.9 34.6 Compressor Rated load amps 9.0 13.5 14.1 16.7 21.2 24.2 26.3 Locked rotor amps 48 58.3 73 ! 70 .90 100 125 Power factor 0.98 0.98 0.98 0.99 0.99 0.99 0.99 Condenser Full load amps 0.7 0.7 1.1 1 1.1 1.7 1.7 1.7 Fan Motor Locked rotor amps 1 1.3 1.3 2.0 2.0 3.2 3.2 3.2 OPTIONAL ACCESSORIES- ORDER SEPARATELY Compressor Crankcase Heater 93M04 • • • 93M05 • • • Compressor Hard Start Kit 10J42 88M91 • Compressor Low Ambient Cut-Off 45F08 • Compressor Sound Cover 69J03 • Compressor Time-Off Control 47J27 • Freezestat 3/8 in.tubing 93G35 • 5/8 in.tubing 50A93 1 • • Indoor Blower Off Delay Relay 58M81 • Loss of Charge Switch Kit 84M23 • 'Low Ambient Kit 34M72 • • • • • • • Mounting Base 69J06 - 69J07 • • • Refrigerant L15-41-20,L15-41-30, Line Sets L15-41-40,L15-41-50 L15-65-30,L15-65-40, • • • L15-65-50 Unit Stand-Off Kit 94J45 _ • NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. 'Refrigerant charge srdriaent for 15 ft.kngth of refrigerant lines.For longer line set requirements see the Instalatlon Instructions for information about ine set length and additional refrigerant charge required. 'HACR type circuit breaker GI-fuse. 'Refer to National or Canadian Electrical Code manual to determine wire,'use and disconnect size requirements. 'Crankcase Heater and Freezestat are recommended with Low Ambient Kt. 13ACX-1.5 to 5 Ton Air Conditioner /Page 6 Aug 27 15 03:07p Honke Heating 503-666-0589 p.4 SOUND DATA Octave Band Linear Sound Power Levels dB,re 10.72 Watts 'Unit Center Frequency-HZ 'Sound Rating Model No. Number(dB) 125 250 500 ,1000 2000 4000 8000 13ACX-018 53 60 64.5 68.5 67 61.5 54.5 76 13ACX-024 51.5 62 64.5 168.5 67 60.5 53.5 76 13ACX-030 52.5 62 67.5 69 67 61.5 54.5 76 13ACX-036 52.5 61 67 69 67 61.5 52.5 76 13ACX-042 58 68 73.5 :75.5 74 69.5 62.5 79 13ACX-048 57.5 67 73 74.5 71 64 58.5 79 13ACX-060 57 63 69.5 '71.5 71 65.5 60.5 79 _ NOTE-tie octave sound power data does not include tonal correctiol_ 'Tested according toAHRI Standard 27C-2008 test conditions. FIELD WIRING INSTALLATION CLEARANCES - IN.(MM) 4 r DISCONNECT 1 r THERMOSTAT-II r DISCONNECT 1 See NOTES SWITCH (Optional) I I SWITCH L�Hy Others) J L J L (By Others) J CIA i CD 0 (Al ri," ' . +4 See- — O 'fSee liw NOTES % NOTES LENNOX LENNOX ` `, AIR / HEATING UNIT CONDITIONER OR AIR HANDLER CONTROL UNIT See NOTES BOX A -Two Wire Power NOTES: B -Two Wire Power(See Electrical Data) Service clearance of 30 in. (762 mm)must be maintained on C -Two Wire Low Voltage(18 ga.minimum) one of the sides adjacent to the control box. D -Four Wire Low Voltage(Electro-Mechanical)18 ga.mini- Clearance to one of the other three skies must be 36 in.(914 mum. mm) Five Wire Low Voltage(Electronic) 18 ga. minimum Clearance to one of the remaining two sides may be 12 in.(305 mm)and the final side may be 6 in. (152 mm). NOTE-Field Wiring Not Furnished A clearance of 24 in. must be maintained between two units. All wiring must conform to NEC or CEC and local electrical codes. 48 in. (1219 mm)clearance required on top of unit. 13ACX-1.510 5 Ton Air Conditioner /Page 8