FIRE PROTECTION
EQUIPMENT SUBMITTAL
tLICQWorldwide www.tyco-fire.com
Fire Protection Contacts
_ Products
. Series TY-B, 5.6 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Standard Response, Standard Coverage
General NOTICE
The Series TY-B Sprinklers described I jai • r.,� I
Description herein must be installed and maintained T j t k.`
in compliance with this document, as "
The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards t `i
Upright (TY315)and Pendent(TY325) of the National Fire Protection Associa-
Sprinklers /��
described in this data sheet tion,in addition to the standards of any d�"�
are standard response,standard cover- other authorities having jurisdiction. fp
age,decorative 5 mm glass bulb type Failure to do so may impair the per for-
spray sprinklers designed for use in mance of these devices. ,;
light, ordinary, or extra hazard, corn- - " l�
mercial occupancies such as banks, The owner is responsible for maintain
hotels, shopping malls, factories, ing their fire protection system and
refineries, and chemical plants. devices in proper operating condition.
The installing contractor or sprinkler
The recessed version of the Series manufacturer should be contacted with
TY-B Pendent Sprinkler, where appli- any questions.
cable,is intended for use in areas with a
finished ceiling.This recessed pendent S
pr sprinkler uses one of the following: p "_ 1
T74.
• A two-piece Style 15 Recessed Identification r 1
Escutcheon with recessed adjust-
ment up to 5/8 inch (15,9 mm) from Numbers (SINs)
the flush pendent position.
• A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2""NPT
Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT ,' •.
ment up to 1/2 inch (12,7 mm)from
the flush pendent position. Technical
The adjustment provided by the Temperature Ratings
Recessed Escutcheon reduces the Data 135°F(57°C)
accuracy to which the fixed pipe drops 155°F(68°C)
to the sprinklers must be cut. Approvals 175°F(79°C)
UL and C-UL Listed 200°F(93°C)
Intermediate level versions of Series FM, LPCB,and VdS Approved 286°F(141°C)
TY-B Sprinklers are described in CE Certified 360°F(182°C)t
Technical Data Sheet TFP352.Sprinkler
guards and shields are described in Sprinklers with Polyester Finish are t UL.C-UL,and VdS Approved only
Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion-
Resistant Sprinklers. Finishes
Sprinkler: Refer to Table A
Maximum Working Pressure Recessed Escutcheon:White Coated,
175 psi(12.1 bar) Chrome Plated,or Brass Plated
250 psi(17.2 bar)`
'The maximum working pressure of 250 psi Physical Characteristics
(17.2 bar)only applies to the listing by Un- Frame Bronze
IMPORTANT derwriters Laboratories, Inc.(UL). Button Brass/Copper
Always refer to Technical Data Sealing Assembly Stainless
Sheet TFP700 for the 'INSTALLER Discharge Coefficient Steel w/TEFLON
WARNING" that provides cau- K= 5.6 GPM/psis 2(80,6 LPM/bar 2) Bulb Glass
tions with respect to handling and Compression Screw Bronze
installation of sprinkler systems and Deflector Bronze
components. improper handling and
installation can permanently dam-
age a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 4 FEBRUARY 2014 TFP152
TFP152
Page 2 of 4
Components: *Temperature rating is ** Pipe thread connections per ISO 7-1
1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request.
' 2 - Button 5 - Compression STYLE 15 or 20
3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED
Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON
6
--- /
5 'mil 7/16--i "
I !-_
(11,1 mm) —� i• _
4 NOMINAL ' 2" I
MAKE-IN �_ (50,82'm'
I 2 r- `` q 2" 1-3/8"OP
�1 0.` (50,8 mm) (34,9 mm) I ` r
o 1 7
ri
WRENCH
1/2"NPT** DEFLECTOR* [ 2-7/8"(73,0 mm)DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 1
SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE
�, Operation Installation
The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor,
WRENCH RECESS expands when exposed to heat.When Upright(TY315)and Pendent (TY325)
(USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor-
END"A") fluid expands sufficiently to shatter the dance with this section.
^ glass bulb, allowing the sprinkler to
FIGURE 2 activate and water to flow. Do General Instructions
not install any bulb type sprinkler if
W-TYPE 6 the bulb is cracked or there is a loss of
SPRINKLER WRENCH _ Design liquid from the bulb.With the sprinkler
held horizontally, a small air bubble
_
WRENCH Criteria should be present.The diameter of the
WREN
RRCNS air bubble is approximately 1/16 inch
The TYCO Series TY-B, 5.6 K-factor, (1,6 mm)for the 135°F (57°C) to 3/32
Upright(TY315)and Pendent(TY325) inch (2,4 mm) for the 360°F (182°C)
� Sprinklers are intended for fire protec temperature ratings.
/I—� tion systems designed in accordance
with the standard installation rules A leak-tight 1/2 inch NPT sprinkler
recognized by the applicable Listing joint should be obtained by applying a
or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14
`� is based on the requirements of NFPA ft.-Ibs. (9,5 to 19,0 Nm). Higher levels
N.r, 13, and FM Approval is based on the of torque may distort the sprinkler inlet
PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the
IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler.
ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for
WITH SPRINKLER applicable,is to be used for recessed insufficient adjustment in the escutch-
WRENCHING AREA pendent installations. eon plate by under-or over-tightening
FIGURE 3 the sprinkler. Readjust the position of
W-TYPE 7 RECESSED
the sprinkler fitting to suit.
SPRINKLER WRENCH Upright and Pendent Sprinklers
The Series TY-B Upright and Pendent
Sprinklers must be installed in accor-
dance with the following instructions.
Step 1. Install pendent sprinklers in
the pendent position; install upright
sprinklers in the upright position.
. Step 2. With pipe-thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
TFP152
Page 3 of 4
Step 3.Tighten the sprinkler into the 2-7/8"DIA.
sprinkler fitting using only the W-Type – (73,0 mm)
. 6 Sprinkler Wrench (Figure 2). With
reference to Figure 1,apply the W-Type 2-1/4"DIA.
6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) —
Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER
- 19,0 Nm). FITTING
5/8"(15,9 mm)
Recessed Pendent Sprinklers i \ - FLUSH
The Series TY-B Recessed Pendent 3/8±5/16" =_1 1
Sprinklers must be installed in accor- (9,5±7,9 mm) _api. . 1/ i
dance with the following instructions. + ' g� }
Step A.After installing the Style 15 or MOUNTING
1/8" J
Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm)
over the sprinkler threads and with -- —
pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm)
threads,hand-tighten the sprinkler into TY-B PLATE 3/4"(19,1 mm)
the sprinkler fitting.
Step B.Tighten the sprinkler into the FIGURE 4
sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325)
7 Recessed Sprinkler Wrench -Type WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15
3).With reference to Figure 1,apply the RECESSED ESCUTCHEON
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats. Torque 2-7/8"DIA.
sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm)
Nm). FACE OF
Step C.After the ceiling is installed or SPRINKLER —2-1/4"DIA.
the finish coat is applied,slide on the FITTING (57,2 mm) —�
Style 15 or Style 20 Closure over the 5/16±1/4"
Series TY-B Sprinkler and push the (7,9±6,4 mm) 1/2"(12,7 mm)
Closure over the Mounting Plate until - FLUSH
its flange contacts the ceiling. 1
Care and t I }
MOUNTING 1/8 J Mainteance SURFACE (3,2 mm)
The TYCO Series TY-B, 5.6 K-factor,
Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm)
Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm)
viced in accordance with this section. FIGURE 5
Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325)
main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20
work on the fire protection system RECESSED ESCUTCHEON
that it controls, obtain permission to
shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the
system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of
and notify all personnel who may be corrosive products of combustion,but their fire protection system and devices
affected by this action. have not operated,should be replaced in compliance with this document, as
Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards
escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa-
a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the
operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav-
ing
owner must assure that the age to the sprinklers- before, during, ing jurisdiction. Contact the installing
and after installation. Sprinklers dam- contractor or sprinkler manufacturer
sprinklers are not used for hanging regarding any questions.
any objects and that the sprinklers are aged by dropping, striking, wrench
only cleaned by means of gently dust- twist/slippage, or the like, must be Automatic sprinklers are recommended
ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained
non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in
inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements
Section.) and/or national codes.
Sprinklers which are found to be leak Thereafter, annual inspections per
ing or exhibiting visible signs of corro NFPA 25 are required;however,instead
sion must be replaced. of inspecting from the floor level, a
Automatic sprinklers must never be random sampling of close-up visual
painted, plated, coated, or otherwise inspections should be made.
altered after leaving the factory.
- - ---
TFP152
Page 4 of 4
P/N* 77 - XXX - X - XXX
SIN SPRINKLER TEMPERATURE
FINISH RATINGS
570 5.6K UPRIGHT(1/2'NPT) TY315 1 NATURAL BRASS 135 135°F(57°C)
571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010)" 155 155°F(68°C)
POLYESTER
•Use suffix 1"for ISO 7-1 connection; SIGNAL WHITE(RAL9003)
for example,77-570-4-175-I 4 POLYESTER 175 175°F(79°C)
9 CHROME PLATED 200 200°F(93°C)
'*Eastern Hemisphere sales only 286 286°F(141°C)
360 360°F(182°C)
000 OPEN***
*"OPEN indicates sprinkler
assembly without Glass Bulb,
Button,and Sealing Assembly
TABLE A
SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS
PART NUMBER SELECTION
Limited Ordering
Warranty Procedure
For warranty terms and conditions,visit Contact your local distributor for avail-
www.tyco-fire.com. ability.When placing an order,indicate
the full product name and Part Number
(P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify: Series TY-B Upright or Pen-
dent(specify)Sprinkler, SIN (specify),
K=5.6, Standard Response, (specify)
temperature rating,(specify)finish,P/N
(specify,refer to Table A)
Recessed Escutcheon
Specify:Style 15 Recessed Escutcheon
with(specify*)finish, P/N(specify*)
Specify:Style 20 Recessed Escutcheon
with(specify')finish, P/N(specify')
•Refer to Technical Data Sheet TFP770
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700
Copyright®2014 Tyco Fire Products,LP. All rights reserved. t cc
TEFLON is trademark of The DuPont Corporation. Fire Protection Products
I. Ductile Iron Fittings- Class 300 UL/FM
I QUALM PLUS
c ® us
APPROVED
A
Fig. 35CP3 -Straight Coupling with Ribs
LISTED
Size Part Number A Packing Weight
�'`"�`"-' in in Inner Master lb
1/2 35CP3004 1.38 200 400 0.1
3/4 35CP3006 1.63 100 200 0.2
1 35CP3010 1.75 60 120 0.4
1-1/4 35CP3012 2.00 35 70 0.5
1-1/2 35CP3014 2.19 25 50 0.7
2 35CP3020 2.62 15 30 1.2
2-1/2 35CP3024 3.00 9 18 2.2
Fig. 35RC3 -Hex Reducing Coupling
111 .
Size A Packing Weight
N\ in Part Number in Inner Master lb
7® A 1 x 1/2 35RC3010004 1.69 80 160 0.3
1 x 3/4 35RC3010006 1.69 60 120 0.4
-
i
1-1/4x3/4 35RC3012006 2.06 40 80 0.6
2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0
Fig. 35HB3 -Hex Bushing
Size Part Number A Packing Weight
B in in Inner Master lb
( ) 1 x 1/2 35HB3010004 1.06 180 360 0.2
kIA 1 x 3/4 - 35HB3010006 1.06 180 360 0.1
1-1/4x1 35HB3012010 1.19 90 180 0.2
1111 .
i 35H83014010 1.25 75 11150 0.4
1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3
D . -..x' 35HB3020010 1.38 40 80 0.6
U 2 x 1-1/4 35H B3020012 1.38 40 80 0.6
C 2 x 1-1/2 35HB3020014 1.38 40 80 0.6
T
I Fig. 35SP3 -Square Head Plug
E Size A Packing Weight
in Part Number in Inner Master lb
1/2 35SP3004 0.94 600 1200 0.07
�. A 3/4.41.. 35SP3006 1.12 350 700 0.1
•. AN I 1 35SP3010 1.25 200 400 0.1
1-1/4 35SP3012 1.37 100 200 0.3
1-1/2 35SP3014 1.44 80 160 0.4
2 35SP3020 1.50 45 90 - 0.6
Fig. 35U 3-Union with Brass Seat
0 A Size A Packing Weight
Part Number
in _ in Inner Master lb
�-: ....r 1 35U 3010 2.19 20 40 1.0
1-1/4 35U 3012 2.50 15 30 1.2
1-1/2 35U 3014 2.62 10 20 1.7
2 35U 3020 3.12 6 12 2.4
113 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com
• ,;:,, . . _ 10.52
FireLock® Outlet-T `®us O VdS 9?�B
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 922
The Style 922 Outlet-T provides a convenient method of incorporating V,/,and 1/15,20
and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and
• other outlet products.Available for 11/2 through 76.1 mm/32 to 76.1 mm piping systems,Style
922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS r
Approved for direct sprinkler connection only on wet and dry systems.
The locating collar engages into the hole prepared in the pipe.When tightened,the assembly
compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up
to 300 psi/2068kPa and VdS rated up to 16bar at the ambient temperatures typical for fire
protection systems.
Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.*
Contact Victaulic for other optional coatings.
*Consult Section 10.01 for specific listings/approvals.
•
MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to
ASTM A-395,grade 65-45-15,is available upon special request.
Gasket:
• Grade"E"EPDM-Type A
(Violet color code).FireLock products have been Listed by Underwriters Laboratories Inc.and
Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the
rated working pressure using the Grade"E"Type A Gasket System.
Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical
requirements of ASTM A-449 and physical requirements of ASTM A-183.
Housing Coating:
• Orange enamel(North America,Latin America,Asia Pacific)
• Red enamel(Europe)
JOB/OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulid
FEV G 10.52 1
•
. 1
IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52
•
FireLock® Outlet-T
STYLE 922
DIMENSIONS Size Hole A
• pprox.
mchrelmni Dimensions-incheshnillimeters ' Weight Each
Rim X Brach-1 EPTI Y Z
0.001.0.0 T. V W Y Z 1 Ihslkg
154 X 11 13/16 1.30 1.83 1.10 3.87 2.56 1.0
��� \ 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45
ift Illira. 20 1 0.2 1.28 6.5 1.10 98.3 65.0 .5� Zd 30.2 32.5 46.5 279 98.3 65.0 0.50
1 ■ u��� � VV
ill 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2
�� I I 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54
11/2 K 13/16 1.42 1.95 1.22 4.08 2.56 1.2
40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54
114 1 3/16 1.40 1.95 1.22 4.08 2.56 1.2
20 30.2 35.6 49.5 31.0 103.6 65.0 0.54
1 13/16 1.64 2.30 1.22 4.08 2.56 1.3
25 30.2 41.7 58.4 31.0 103.6 65.0 0.59
2 54 13/16 1.66 2.19 146 4.60 2.56 1.3
50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59
14 13/16 1.64 2.19 1.46 4.60 2.56 1.4
20 30.2 41.7 55.6 37.1 116.8 65.0 0.64
1 13/16 1.88 2.54 146 4.60 2.56 1.5
25 30.2 47.8 645 371 116.8 65.0 0.68
211 lh 13/16 1.91 2.44 1.71 5.40 2.56 1.6
65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73
14 1 3/16 1.89 2.44 1.71 5.40 2.56 1.6
20 30.2 48.0 62.0 43.4 137.2 65.0 0.73
1 13/16 2.13 2.79 1.71 5.40 2.56 1.6
25 30.2 54.1 70.9 43.4 137.2 65.0 0.73
76.1 mm X N 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6
15 30.2 48.5 62.0 43.4 139.7 65.0 0.73
14 1 3/16 1.89 2.44 1.71 5.50 2.56 1.6
20 30.2 48.0 62.0 43.4 139.7 650 0.73
1 13/16 2.13 2.79 1.71 5.50 2.56 1.7
25 30.2 54.1 70.9 43.4 139.7 65.0 0.80
t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional)
male pipe threads only.Use of male threaded products with special features,such as probes,dry pen-
dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify
suitability in advance may result in assembly problems or leakage.
"Center of run to engaged pipe end for NPT threads(dimensions are approximate).
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. gCVlgr..A •
72.52 2 REV G
•
IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 10.52
FireLock® Outlet-T
STYLE 922
PERFORMANCE
Equivalent Length of 1 inch
Schedule 40 Steel Pipe(per UL
Run Size x Outlet Size 213,Section 16)(C=120)•,FT
114 x 8.5
32 S 2.6
115 1 8.5
40 x 25 2.6
2 x 1 8.5
50 25 2.6
21.4 X 1 8.5
65 25 2.6
76.1 mm X 1 8.5
25 2.6
•Hazen-Williams coefficient of friction is 120
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaUIuC.'
REV G 10.52 3
FireLock® Outlet
STYLE 922
INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product
you are installing.Handbooks are included with each shipment of Victaulic products for complete
installation and assembly data,and are available in PDF format on our website at www.victaulic.com.
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
•
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be
installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the
right to change product specifications,designs and standard equipment without notice and without
incurring obligations.
For complete contact information,visit www.victaulic.com
10.52 3355 REV G UPDATED 12/2009 iCtui`.P
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED.
10.52