Report Version#48.9 SolarCity RU RECEI\/ED August 11, 2015 AUG 3 2015 Project/Job # 9722862 RE: COVER LETTER CITY OF 'r 1(.1A-10 BUILDING Div f;�nN Project: Menzalji Residence 12773 SW Morning Hill Ct Tigard,OR 97223 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: - Applicable Codes = 2010 OSISC&2010 OSSC,ASCE 7-05, and 2005 NDS - Risk Category = II - Wind Speed = 95 mph, Exposure Category C - Ground/Roof Snow Load = 25 psf(Unreduced) - MP1: Roof DL = 12 psf, Roof LL/SL = 25 psf - MP2: Roof DL = 10 psf, Roof LL/SL = 25 psf On the above referenced project, the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure requires structural upgrades as detailed in the plan set to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. The structural roof framing including the specified upgrades and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the 2010 OSISC&2010 OSSC. sisEO PROFFS Please contact me with any questions or concerns regarding this project. �\co �GINEFR cS/O Digitally signed by <4./ �y John Calvert iFt5PE,/ r Date:2015.08.1 1 John A. Calvert, P.E. 11:42:49-06'00' Professional Engineer Exp: 12/31/15 OREGO T: 888.765.2489 x51508 0;14 y 16 20 J��� email: jcalvert @solarcity.com N A. CA\ 3055 Clearview Way San Mateo,CA 94402 t(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com 08.11.2015 So ar i . PV System Structural Version #48.9 Design Software PROJECT INFORMATION &TABLE OF CONTENTS k, ,.,_ , „ , Project Name: Menzalji Residence AHJ: Tigard Job Number: 9722862 Building Code: 2010 OSISC& 2010 OSSC Customer Name: Menzalji, Mohammad Based On:! IRC 2009/IBC 2009 Address: 12773 SW Morning Hill Ct ASCE Code: ASCE 7-05 IMIIIIIMIFa City/State: Tigard, OR Risk Category: II Zip Code 97223 Upgrades Req'd? Yes Latitude/ Longitude: 45.427957 -122.811142 Stamp Req'd? Yes SC Office: Portland PV Designer: Derrick Olds Cover Letter 1 Project Information,Table Of Contents, &Vicinity Map 2 Seismic Considerations 3 Structure Analysis (Loading Summary and Member Check) 4 Hardware Design (PV System Assembly) 5 1 2-MILE VICINITY MAP .,_ SW Walnut St . . _ l • �'Gl, - gym s - i A.11/c9/nut -- 3. . 0 -, <. `D i .. a•e(.19i ' Digital..lobe, Metro, Portland Oregon. State ofOre•on, U.S. Geological Surve 12773 SW Morning Hill Ct, Tigard, OR 97223 Latitude: 45.427957, Longitude: -122.811142, Exposure Category: C SEISMIC CONSIDERATIONS ' Seismic Design Criteria (per USGS) Seismic Design Code ASCE 7-05 Latitude iffillailinialM AIM 45.4280 MEW Longitude -122.8111 SRA at Short Period 11111111111111111 SS MUM 0.971 USGS SRA at is Period 51 0.347 USGS Soil Site Class Alll 111111 IBC 1613.5.2 Seismic Design Category SDC D USGS Seismic Check Required(Ss a Yes IBC 1613.1 0.4g&SDC a D)? ALTERATION LATERAL DESIGN 10% EXCEPTION CHECK Weight of Proposed PV System Area _ Dead Load Weight PV System Weight 533 sf 3 psf 1,599 lbs Total Weight of PV System W(PV) I 1 1,599 lbs Weight of Roof on Existing Building Sum Area of MPs with PV 1134 sf Portion of Roof Weight Area Dead Load Weight Roof 1,134 sf 10.0 psf 11,341 lbs Ceiling 1,134 sf 7.0 psf 7,939 lbs Interior Walls (Top Half) 539 sf _ 5.0 psf 2,694 lbs Exterior Walls(Top Half) 539 sf 8.5 psf 4,580 lbs Net Weight of Roof Under PV W(e%i ) 26,555 lbs Check % Increase of Roof Weight / Seismic Shear Load Increase of DCR of Lateral 6.0% W W IBC Sect. 3404.4 Force Resisting System �PV�� ce=' > Increase Seismic Shear Load < 10%, -> [OK] Note: Seismic base shear is directly proportional to roof weight. STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 g " Member Properties Summary MP1 Horizontal Member Spans Upgraded Rafter Properties Overhand 1.16 ft Net W _ 3.00" Roof System Properties Span 1 17.41 ft Equiv D 9.25" _ Number of Spans(w/o Overhang) 1 Span 2 _ Nominal _ Yes - Roofing Material Comp Roof Span 3 A 27.74 in.^2 _ Re-Roof No _ Span 4 _ S. 42.77 in.^3 - Plywood Sheathing Yes Span 5 I. 197.80 in.^4 Board Sheathing None Total Span 18.57 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 0.75 ft Wood Species DF Ceiling Finish 1/2"Gypsum Board PV 1 End 15.58 ft Wood Grade #2 Rafter Slope 26° PV 2 Start_ Ft, 900 psi Rafter Spacing 24"O.C. PV 2 End F„ 180 psi Top Lat Bracing Full PV 3 Start E 1600000 psi Bot Lat Bracing At Supports PV 3 End Em;" 580000 psi Member Loading Summary Roof Pitch 6/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 12.0 psf x 1.11 13.4 psf 13.4 psf PV Dead Load PV-DL 3.0 psf x 1.11 3.3 psf Roof Live Load RLL 20.0 psf x 0.90 18.0 psf Live/Snow Load LL/SL1'2 25.0 psf x 1 1 X 1 25.0 psf 25.0 psf Total Load(Governing LC) TL 38.4 psf 41.7 psf Notes: 1. ps = Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(Cr)(IS)p9; Ce=0.9,Ci=1.1, I5=1.0 Member Design Summa (per NDS) Governing Load Comb CD CL(+) CL(-) 1 CF Cr D + S 1.15 1.00 0.89 1.1 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 36 psi 1.2 ft. 207 psi 0.18 D + S Bending(+)Stress 875 psi 9.9 ft. 1309 psi 0.67 D+S Bending(-)Stress -15 psi 1.2 ft. -1160 psi 0.01 D + 5 Total Load Deflection 0.66 in. I L/350 9.9 ft. _ 1.94 in. I L/120 0.34 _ D+S CALCULATION OF DESIGN WIND LOADS - MP1 Mountin• Plane Information Roofing Material Comp Roof PV System Type miimmei SolarCity SleekMountTM ■ Spanning Vents No ■ I Standoff Attachment Hardware ,u I Me n T .- Roof Slope 26° Rafter Spacing ow 24" O.C. " Framing' T .e Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA < I Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA r' " Standing, Seam Ira. 5.acin. SM Seam Onl NA Wind Design Criteria . ` Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig. 6-1 Exposure Category SIMMOPIIIIMMEMI MISSEIMMI C MI11111,111111 Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 11k_AIEIEIIIIIIr 15 ft__AMIIIIIIIIIIL. Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor ® IC s IMINWRIWAIMIN 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I ® 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd) (VA2)(I)16.7 psf Equation 6-15 Wind Pressure Ext. Pressure Coefficient(Up) GCo -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GC, °` 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh (GC,) Equation 6-22 Wind Pressure Up P uo) -14.6 psf Wind Pressure Down P(down) 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction V-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib _ sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual ==-c; ,.' ,:'.?. -253 lbs .11 MOM Uplift Capacity of Standoff T-allow 500 lbs - Standoff Demand/Capacity DCR IV_____ n____r 50.6% MEMBEINEllr X-Direction _'` V-Direction Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait ISMOSNXIO 20" diniall.m. mg NA Standoff Configuration Portrait Sta eyed Max Standoff Tributary Area Trib sf 11111111111.111. 111111111.1111 PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff illE 1 T-actual 2'- •.,,. 2 -283 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 56.7% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP2 Member Properties Summary MP2 Horizontal Member Spans Rafter Properties Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 10.58 ft Actual D 7.25" Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A 10.88 in.^2 Re-Roof No Span 4 Sx 13.14 in.^3 Plywood Sheathing Yes Span 5 Ix 47.63 in.^4 Board Sheathing None Total Span 11.74 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 0.92 ft _ Wood Species DF Ceiling Finish 1/2"Gypsum Board PV 1 End 9.83 ft Wood Grade #2 Rafter Slope _ 26° PV 2 Start Fb 900 psi Rafter Spacing 24"O.C. PV 2 End F„ 180 psi Top Lat Bracing Full PV 3 Start E 1600000 psi Bot Lat Bracing At Supports PV 3 End Emi„ 580000 psi Member Loading Summary Roof Pitch 6/12 Initial Pitch Adjust , Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.11 11.1 psf 11.1 psf PV Dead Load PV-DL 3.0 psf x 1.11 3.3 psf Roof Live Load RLL 20.0 psf x 0.90 18.0 psf Live/Snow Load LL/SL1'2 25.0 psf x 1 I x 1 25.0 psf 25.0 psf Total Load(Governing LC) TL - 36.1 psf 39.5 psf Notes: 1. ps = Cs*pf; Cs-roof, Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(Ct)(Is)p9; Ce=0.9,Cr=1.1,IS=1.0 Member Design Summa (per NDS) Governing Load Comb CD CL(+) CL(-) CF Cr D + 5 1.15 1.00 0.56 1.2 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 56 psi 1.2 ft. 207 psi 0.27 D + Bending(+)Stress 980 psi 6.5 ft. 1428 psi 0.69 _ D+S Bending (-)Stress -45 psi 1.2 ft. _ -804 psi 0.06 D -+ S Total Load Deflectbn 0.35 in. I L/404 6.5 ft. 1.18 in. I L/120 0.30 -- CALCULATION OF DESIGN WIND LOADS - MP2 INIMMINIMMIIIMEMMEMEINIMIN Mounting Plane Information ' ' Roofing Material Comp Roof PV System Type SolarCity SleekMount' Spanning Vents No Standoff(Attachment Hardware) _ Comp Mount Tvoe C T Roof Slope 26° Rafter Spacing — 24"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only Mansamm NA IMMINUIf Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method gam. • . Partially/Fully Enclosed Method IIIII Basic Wind Speed V 95 mph Fig. 6-1 Exposure Category MN MN C _.111111 Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B _ Mean Roof Height h 15 ft.A11111111.1r Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor sommEN Krt misasommismann 1.00 ummaisomor Section 6.5.7 - Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I ingiumemmasimaimmiti 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt) (Kd)(V^2)(I) Equation 6-15 16.7 psf Wind Pressure Ext. Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GC,)(Down) 0.45 —"IL; Fig.6-11B/C/D-14A/B Design Wind Pressure p p — (1,, (GC ) Equation 6-22 Wind Pressure Up Pun) -14.6 psf Wind Pressure Down Pmown) 10.0 psf ALLOWABLE STANDOFF SPACINGS y I X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area 111Pm0m Trib 20 sf ma PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff EN T-actual =w= -253 lbs '"Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 50.6% I` X-Direction ',;, Y-Direction Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" nalliffintr NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff I T-actual -283 lbs =MUM Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 56.7%