Specifications 0 MILLER CONSULTING ENGINEERS STRUCTURAL CALCULATIONS Mod Pizza Signage 12196 SW Scholls Ferry Road, Tigard, Oregon Ramsay Signs July 21, 2015 Project No. 150829 6 pages Principal Checked: It*/ _ ,<&5) PRO,c� o ss/ qr 4` 72525PE P Ali 9 �lcy'/ o a .PrQIQ •SEPH k EXPIRES:12-31-2016 *** LIMITATIONS *** Miller Consulting Engineers, Inc. was retained in a limited capacity for this project. This design is based upon information provided by the client, who is solely responsible for accuracy of same. No responsibility and or liability is assumed by or is to be assigned to the engineer for items beyond that shown on these sheets. Engineering Practical,Diverse Structural Solutions Since 1978 9570 S W Barbur Blvd.,Suite 100, Portland,Oregon 97219-5412 Phone:(503)246-1250 Fax:(503)246-1395 www.miller-se.com WIND LOADING ANALYSIS-Wall Components and Cladding Scope of work is for the design of the connection of the wall sign to the existing structure only. . Input Data: — -- , ASCE 7-10 Wind Speed,V= 120.00 mph Bldg.Classification= II (Table 1-1 Occupancy Category) Exposure Category= B B Ridge Height,hr= 30.00 ft.(hr>.he) Eave Height,he= 30.00 ft.(he<=hr) Building Width= 200.00 ft.(Normal to Building Ridge) - Building Length= 200.00 ft.(Parallel to Building Ridge) I L Roof Type= Monoslope (Gable or Monoslope) N Topo.Factor,Kzt= 1.00 Plan Direct.Factor,Kd= 0.85 Enclosed?(YIN) Y nr, the Resulting Parameters and Coefficients: 14 L Elevation Roof Angle,0= 0.00 deg. Mean Roof Ht.,h= 30.00 ft.(h=he,for roof angle<=10 deg.) Wall External Pressure Coefficients,GCp: GCp Zone 4 Pos.= 0.81 GCp Zone 5 Pos.= 0.81 GCp Zone 4 Neg.= -0.90 GCp Zone 5 Neg.= -1.08 If z<=15 then: Kz=2.01•(15/zg^(2/a), If z>15 then: Kz=2.01*(z/zg)^(2/a) a= 7.00 (Note:z not<30'for Exp.B,Case 1) zg= 1200 Kb= 0.70 (Kh=Kz evaluated at z=h) Velocity Pressure: • qh= 13.17 psf qh=0.00256*Kh*KzYKd•V^2*0.6 (qz evaluated at z=h) Wall Pressure for Anchor Design (allowable) Design Net External Wind Pressures. F= -11.88 psi Sign Dead Load= 4.00 psf(max) Fastener Capacities: Tc= 195 lb Vc= 140 lb offset= 0.00 in o.d.of spacer= 0.00 in Max trib.area= 11.17 ft2 =1/(((-11.88'-1)/1951b+4/140lb) Provide 0.375"dia.Powers Toggle Bolt for every 11.17 sqft.of trib. 16'-0.314' F O O O O O O O° 0 0 0 0 0 0 O 0 00 °O °° ° 0 ° 0 °'G C 0 0 0 o O ° 0 ° O°'° 0000 O O o WS IMGoN u A nt ed° °° ° ° O O ° O O °O° O 0 O 0 0 0 0 0 0 0 0 O 0 O _ SUPER FAST Mod Pizza Signage 150829 9570 SW Barbur Blvd Project Name Project# at Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM 7/21/15 1 of 6 www.miller-se.com By - Ck'd Date Page _ ENGINEERS • WIND LOADING ANALYSIS -Parapet Loading Per ASCE 7-10 Code for Bldgs.of Any Height with Gable Roof 8<=45°or Monoslope Roof 0<=3° Using Method 2:Analytical Procedure Input Data: . Wind Speed,V= 120.00 mph Risk Category= II Exposure Category= B B Ridge Height, hr= 20.00 ft. (hr>=he) Eave Height, he= 20.00 ft. (he<=hr) Building Width= 100.00 ft. (Normal to Building Ridge) 1 ' Building Length = 100.00 ft. (Parallel to Building Ridge) I L Roof Type= Monoslope (Gable or Monoslope) h �I Topo. Factor, Kzt= 1.00 Plan Direct. Factor, Kd= 0.85 Enclosed?(Y/N) Y Effective Area.Ae= 18.28 ft2 (Area Tributary to C&C) 0 ki . Resulting Parameters and Coefficients: hr Roof Angle, 0= 0.00 deg. he Mean Roof Ht., h = 20.00 ft. (h=he,for roof angle<=10 deg.) ' L Elevation If z<=15 then: Kz=2.01*(15/zg ^(2/a) , If z> 15 then: Kz=2.01*(z/zg)^(2/a) (Case la) a= 7.00 zg= 1200 (Note:z not<30, Exp. B,Case 1) Kh= 0.70 (Kh=Kz evaluated at z= h) Velocity Pressure:qz=0.00256*Kz*Kzt*Kd*V2*0.6 qh(qp)= 13.17 psf Roof External Pressure Coefficients,GCp: GCp Zone 2 Neg.= -1.62 Wall Pressure Coefficients, GCp: GCp Zone 4 Pos. 0.86 GCp Zone 4 Neg. = -0.95 Load Case A-loads acting towards the building qp= 13.17 psf GCp= 2.48 =0.86+1.62(positive wall load on face of parapet and negative roof edge zone load to back of parapet) Gcpi= 0 p= 32.7 psf Load acting towards the building Load Case B-loads actin• awa from the building qp= 13.17 psf GCp= 1.81 =0.86+0.95(postive wall load on back of parapet and negative wall load on face of parapet) Gcpi= 0 p= -23.8 psf Load acting away from building 13'-4-314' _I 0 0 0 0 0 0 0 0 000 000 00 SIGN C 00 00 ° ° o ° 0'0 0 0 0 00 0 00 0 o Q 0 0 0110 0 0 0 010 0 0 0 0 0 0 0 0 0 0 0 0 000 0 0 ° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000 000 0 0 �____3 � SUPER FAS� Mod Pizza Signage 150829 9570 SW Barbur Blvd Project Name Project# Art Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJMJ 7/21/15 2of6 www.milier-se.com By Ck'd Date Page ENGINEERS Sign Geometry: Width= 160.75 in IIU L22a1/4,TVP. Height= 50 in s/s D1 B°LT• Trib.to brace= 45 in TYP. • w= 123 plf =32.7psf*45"/12 x1 = 24 in 112'DIA.POWERS 3 O•D, x2= 26 in : TOGGLE BOLT,TYP, �yp. Mvertical angle= 289 ft-lb = 123*(26"/12)^2/2 . SIN• i See next page for an le check, Use L2X2X3/16 tv0� R2= 534 lb =123*(50"112)^2/21(24"/12) ' rv. p� R1 = -22 lb =123*50"/12-534 Brage angle 1= 45 deg.from vertical(min.) — a -''r Pbrace angle= 755 lb =534/SIN(45deg.) 11r See page after next for angle check, Use L1 X1 X1/8(min.) 7 (E)ROOF. III'. VERIFY SLOPE Horiz.angle span= 36 in location of brace conn.= 18 in Mhonzontal angle= 401 ft-lb =534/TAN(45deg.)*(18"*18)"/36"/12 See last pa.e for an.le check, Use L2X2X1/4(min.) Weight= 4 psf Fastener Checks: #of anchors= 3 at each end of connection spacing= 36 in Vanchors= 85 lb =123*50/12/(6 fasteners) Tanchore= 98 =(123*(50"/12)^2/2/(36"/12)-4*45/12*50/12)/(3 fasteners) Vc= 160 lb Tc= 230 lb Comb.= 0.96 <1.00 OK Use 112"dia.Powers toggle bolts • Mod Pizza Signage 150829 9570 SW Barbur Blvd Project Name Project# 4114 Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM 7/21/15 3of6 www.miller-se.com By Ck'd Date Page ENGINEERS Steel Column/Beam Design-AISC 13th Addition Vertical Bracket Angle Shape: L Shape Capacity=0.72 <1.0 Size: L2X2X3/16 ASD Axial Capacities,Chapters D and E Pr= 0.06 K axial compression load Equal Legged Angle Mr,= 0.29 ft-k,strong axis moment Mr„= 0.00 ft-k,weak axis moment Tension Capacity,Chapter D N/A Vr,= 0.53 k,strong axis shear Connection: Welded connnection Vr3= 0.00 k,weak axis shear U= 0.81 Table D3.1,pg 16.1-29 Tr= 0.00 in-k,torsion Ae= 0.58 in2 Vt= 0.00 k,shear due to torsion Pn= 25.74 k K= 2.10 (Table C-C2 2,pg 16 1-240) Comp.Capacity,Chapter E Lb,= 2.17 ft KUr= 140.4 Lb1= 2.17 ft Ur= 42 E= 29000 ksi Fcr= 12.74 ksi Fy= 36 ksi Pn= 9.11 k.(Section E3 pg 16 1-33) Fu= 58 ksi Flexural Capacity,Chapter F Ag= 0.72 in2 Strong Axis: lx= 0.271 in4 Max.compression at toe ly= 0.271 in4 Mnx=4 0.67 ft-k r,= 0.612 in Weak Axis. ry= 0.612 in Max.compression at toe rz= 0.389 in Mny=I 0.67 Ift-k b= 2 in Shear Capacity,Chapter G d= 2 in Cv= 1 t= 0.1875 in Awx= 0.38 in2 S,= 0.188 in' Awy= 0.38 in2 J= 0.0092 in4 kv= 1.2 bI= 2 in Vnx= 8.10 k equation G2-1 bs= 2 in Vny= 8.10 k bl/bs= 1.00 leg length ratio Allowable Capacties Rn/S 1(ASD);Rn• h(LRFD) bl/t= 10.67 (LRFD) Pc,k Pc,k Mc,ft-k Vc,k bs/t= 10.67 x-axis 5.46 15.41 0.40 4.9 O,= 1.67 (Section El.pg 161-32) y-axis (compression) (tension) 0.40 4.9 fib= 1.67 (Section F1,pg 16.1-46) Interaction Equations: Qv= 1.67 (Section Fl,pg 16146) Shear capacity=0.11 < 1.0 OK h�= 0.9 (Section El,pg 16.1-32) Pr/Pc= 0.01 <0.2,Equation Hl-lb controls hb= 0.9 (Section Fl,pg 16.146) 0.72 <1.0 OK J $„= 0.9 (Section FI.pg 16 1-46) Equation Hl-lb,AISC 13 ed.,pg 16.1-70 Section is Compact in the leg for flexure I Use L2X2X3/16 Section is Compact in the long leg for compression Section is Compact in the short leg for compression at 9570 SW Barbur Blvd Project Name Mod Pizza Signage 150829 Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Project# Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM1,) 7/21/15 4of6 www.miller-se.com BY Ck'd Date Page ENGINEERS Steel Column/Beam Design-AISC 13th Addition Diagonal Bracket Angle(brace angle) Shape: L Shape Capacity=0.64 <1.0 Size: L1X1X1/8 ASD Axial Capacities,Chapters D and E Pr= 0.76 k,axial compression load Equal Legged Angle Mr,= 0.00 ft-k,strong axis moment Mry= 0.00 ft-k,weak axis moment Tension Capacity,Chapter D N/A Vry= 0.00 k,strong axis shear Connection: Welded connnection Vry= 0.00 k,weak axis shear U= 0.90 Table D3.1,pg 16.1-29 Tr= 0.00 in-k,torsion Ae= 0.21 in2 Vt= 0.00 k,shear due to torsion Pn= 8.42 k K= 1.00 (Table C-C2.2,pg 16 1-240) Comp.Capacity.Chapter E Lb,= 2.82 ft KL/r= 172.7 Lby= 2.82 ft L/r= 111 E= 29000 ksi Fcr= 8.42 ksi Fy= 36 ksi Pn= 1.97 k,(Section E3 pg 16.1-33) Fu= 58 ksi Flexural Capacity,Chapter F N/A Ag= 0.23 in2 Strong Axis: lx= 0.022 in4 Max.compression at toe ly= 0.022 in` Mnx= 0.11 ft-k rx= 0.304 in Weak Axis: ry= 0.304 in Max.compression at toe ry= 0.196 in Mny=1 0.11 jft-k b= 1 in Shear Capacity,Chapter G N/A d= 1 in Cv= 1 t= 0.125 in Awx= 0.13 in2 S„= 0.031 in3 Awy= 0.13 in2 J= 0.0013 in4 kv= 1.2 bl= 1 in Vnx= 2.70 k equation G2-1 bs= 1 in Vny= 2.70 ,k bl/bs= 1.00 leg length ratio Allowable Capacties Rn/ ](ASD);Rn*<I (LRFD) • bl/t= 8.00 (LRFD) Pc,k Pc,k Mc,ft-k Vc,k bs/t= 8.00 x-axis 1.18 5.04 0.07 1.6 t/c= 1.67 (Section El,pg 16.1-32) y-axis (compression) (tension) 0.07 1.6 t 2b= 1.67 (Section Fl,pg 16.1-46) Interaction Equations: f 1 = 1.67 (Section Fl,pg 161-46) = 0.9 (Section El,pg 16.1-32) Pr/Pc= 0.64 >0.2,Equation H1-la controls = 0.9 (Section F1,pg 16.1-46) 0.64 <1.0 OK rh„= 0.9 (Section Fl,pg 161-46) Equation H1-1a.AISC 13 ed.,pg 16.1-70 Section is Compact in the leg for flexure I Use L1X1X1/8(min.) 1 Section is Compact in the long leg for compression Section is Compact in the short leg for compression at 9570 SW Barbur Blvd Project Name Mod Pizza Signage 150829 Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Project# Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 B CJM Ck'd Date 7/21/15 Page 5 of 6 www.miller-se.com Y 9 ENGINEERS Steel Column/Beam Design-AISC 13th Addition Horizontal Bracket Angle Shape: L Shape Capacity=0.77 <1.0 Size: L2X2X1/4 ASD 'Axial Capacities,Chapters D and E Pr= 0.26 k,axial compression load Equal Legged Angle Mr,= 0.40 ft-k,strong axis moment Mr,= 0.00 ft-k,weak axis moment Tension Capacity,Chapter D N/A Vr,= 0.00 k,strong axis shear Connection: Welded connnection Vry= 0.00 k,weak axis shear U= 0.80 Table 03.1.pg 16.1-29 Tr= 0.00 in-k,torsion Ae= 0.75 in2 Vt= 0.00 k,shear due to torsion Pn= 33.77 k K= 1.00 (Table C-C2.2,pg 16 1-240) Comp.Capacity.Chapter E Lb,= 3.00 ft KL/r= 93.0 Lby= 3.00 ft Ur= 60 E= 29000 ksi Fcr= 22.83 ksi Fy= 36 ksi Pn= 21.41 k.(Section E3 pg 16.1-33) Fu= 58 ksi Flexural Capacity,Chapter F Ag= 0.94 in2 Strong Axis: lx= 0,346 in4 Max.compression at toe ly= 0.346 in4 Mnx= 0.88 ft-k = 0.605 in Weak Axis: ry= 0.605 in Max.compression at toe r,= 0.387 in Mny=I 0.88 1ft-k b= 2 in Shear Capacity,Chapter G N/A d= 2 in Cv= 1 t= 0.25 in Awx= 0.50 in2 S,= 0.244 in3 Awy= 0.50 in2 J= 0.0209 ins kv= 1.2 bl= 2 in Vnx= 10.80 k equation G2-1 bs= 2 in Vny= 10.80 k bl/bs= 1.00 leg length ratio Allowable Capacties Rn/i)(ASD);Rn* b(LRFD) bl/t= 8.00 (LRFD) Pc,k Pc,k Mc,ft-k Vc,k bs/t= 8.00 x-axis 12.82 20.22 0.53 6.5 1.?°= 1.67 (Section El,pg 16.1-32) y-axis (compression) (tension) 0.53 6.5 = 1.67 (Section Fl,pg 16.1-46) Interaction Equations: = 1.67 (Section Fl,pg 16.1-46) ho= 0.9 (Section El,pg 16.1-32) Pr/Pc= 0.02 <0.2,Equation H1-lb controls hn= 0.9 (Section Fl,pg 16.1-46) 0.77 <1.0 OK = 0.9 (Section F1.pg 16.1-46) Equation H1-1b,AISC 13 ed.,pg 16.1-70 Section is Compact in the leg for flexure I Use L2X2X1/4(min.) Section is Compact in the long leg for compression Section is Compact in the short leg for compression Mod Pizza Signage 150829 9570 SW Barbur Blvd Project Name Project# Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJMl,j 7/21/15 6of6 www.miller-se.com By Ck'd Date Page ENGINEERS 3/8"DIA.POWERS TOGGLE BOLT THROUGH(E)PLYWOOD, TYP.(10)LOCATIONS AROUND I 16'-0-314' PERIMETER OF SIGN 00 O 0 0 0 0 0 O 000000 0 0 0 00 0 O0 ODo O O• o o O O 0 0 °0 O ° 0 0 0 0 0 0 0 0 0 0 O 0 O 0 0 0 00 0 0 0 0 0 0 O 0 0 O 0 0 0 0 ° 0 0000 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SUP R FAST EDSIGN ELEVATION SIGN A, WALL MOUNTED N.T.S. NOTES: 1. SCOPE OF WORK IS FOR THE CONNECTION OF THE WALL SIGN TO THE EXISTING STRUCTURE. 2. SEE PAGES 53-S4 FOR STRUCTURAL NOTES. .\<* I N s�/o ,c� 72525PE Ali 1. 0 'SEPH ��' EXPIRES:1241-2018 9570 SW Barber Blvd Project Name Mod Pizza Signage Project# 150829 Si Suite One Hundred Mk Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax By CJM Ck'd Date 7/21/15 Page S1 of 4 ENGINEERS • ®, 13'-4-314' I ',,,'3 PROFFs, , TYP' 72525PE PId -- -- 'y' ' ' ° ti O 0 0 0 0 0 00 0 0 0 0 000 00 q�'�� L° Q 00 00 0 0 O Io 0 O 0 0 0 0 0 l� 09 . e O 0 0 0 o a 0 ° 011 0 0 0 0 010 S 'SEP0 0 0 0 0 0 0 o 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 1212016 O 0 0 0 0 0 0 000 0 0 0 0 0 Li P FR FAST 12 SIGN ELEVATION S2 SIGN C 3/4"=1'-0" V L2x2x1/4,TYP. 3/8"DIA. BOLT, TYP. NOTES: \ 1/2"DIA. POWERS 3.1,10 C, 1. SCOPE OF WORK IS FOR THE -1.. \ TOGGLE BOLT,TYP. BRACKET SUPPORTING THE \ SYP N w SIGN AND ITS CONNECTION M��1. �, TO THE EXISTING STUCTURE. — N \ „ �i•' 2. SEE PAGES S3-S4 FOR 3/4" STRUCTURAL NOTES. TYP Q% -U " mi ji;. 10" c4n 2" 3 (E)ROOF, T(P• VERIFY SLOPE C- BRACKET SECTION 9570 SW Barbur Blvd Mod Pizza Signage 150829 li Project Name Project# St Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road,Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM 7/21/15 S2 of 4 www.miller-se.com By Ck'd Date Page ENGINEERS • GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD. ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2012 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. �\5,<��p PRO o 47:; . 41 72525PE r 9 •r • �° ti � 1* `k•''.. %),p,SEPH EXPIRES:12-31-2016 Mod Pizza Signage 150829 9570 SW Barbur Blvd Project Name Project# at Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJMU 7/21/15 S3of4 www.miller-se.com By Ck'd Date Page ENGINEERS DESIGN LOADS THE FOLLOWING ARE THE DESIGN REQUIREMENTS: STRUCTURAL DESIGN CRITERIA RISK CATEGORY II WIND DESIGN DATA BASIC WIND SPEED(3 SEC GUST) 120 MPH EXPOSURE B ALUMINUM ALL STRUCTURAL ALUMINUM SHAPES AND PLATES TO BE 6061-T6. ALL WELDS TO USE 4043 ALUMINUM FILLER ALLOY.A PROTECTIVE BARRIER SHALL BE PROVIDED BETWEEN ALL STEEL AND ALUMINUM TO PREVENT CORROSION. ALL WELDING TO CONFORM TO AMERICAN WELDING SOCIETY (AWS) D1.2. WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE ALUMINUM DESIGN MANUAL. WELDING SHALL BE BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED. WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS. ALL WELDS TO RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED.ALL FASTENERS IN CONTACT WITH ALUMNIUM TO BE TYPE 304 STAINLESS STEEL WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION. \ccSe PROF /o Fs� 72525PE oa • Q�Q 1SEPH wns EXPIRES:12-31-2016 Mod Pizza Signage 150829 9570 SW Barbur Blvd Project Name Project# Suite One Hundred Portland,OR 97219 12196 SW Scholls Ferry Road, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM ) 7/21/15 S4of4 www.miller-se.com By Ck'd Date Page ENGINEERS