Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
IL CITY OF TIGARD MECHANICAL PERMIT '' 1 II • COMMUNITY DEVELOPMENT Permit#: MEC2015-00523 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/03/2015 Parcel: 1 S 126BC01506 Jurisdiction: Tigard Site address: 9020 SW WASHINGTON SQUARE RD 550 Project: LoanStar Lending Subdivision: 2005-035 PARTITION PLAT Lot: 3 Project Description: Relocate grills Contractor: OREGON HEATING&AIR CONDITIONING Owner: WISCO REAL ESTATE EQUITY FUND I 19300 SW 118TH AVE 1501 SW TAYLOR ST STE 100 TUALATIN, OR 97062 PORTLAND, OR 97205 PHONE: 503-691-9699 PHONE: FAX: 503-691-8556 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 08/03/2015 $96.69 Class of Work: ALT Type of Const: Plan Review 08/03/2015 $24.17 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 08/03/2015 $11.60 Stories: Info Process/Archiving-Sm$0.50(up to 08/03/2015 $0.50 11x17) Project Valuation: $1,400.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $132.96 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notifi - - enter. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direc •uestions to O• C b -- ing 503.232.1987 or 1.800.332.2344. . Issued By: / Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspectio ate. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Appl on CEIV ED FOR OFFICE USE ONIA' Received Him/5 oo5a3 City of Tigard II 2 t Permit No.: ,INI • 13125 SW Hall Blvd.,Tigard,OR 972 3 L U`) Plan -: 1 Phone: 503.718.2439 Fax: 503.598.1960 Date/By: ew Other Permit: ,� �'!7 FIG A R D Inspection Line: 503.639.4175 I #(*-,.►Z® ® See Page 2 for Internet: www.ti ard-oI. OV CITY 0 I Date Ready/By: Juris: S g B1J*t DIN1 t ,')1ON Notified/Method: Supplemental Information Mechanical permit fees'are based on the value of the work ['New construction /. Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor verhe d,and profit. 1 Value:$ ❑ 1-and 2-family dwelling ►:1 Commercial/industrial ❑Accessory building For special Information use checklist. ❑Multi-family • Master builder ❑Other: Description I Qty. I Ea. I Total Heating/cooling: Job site address: "'V Sly Air conditioning 46.75 /� k 4V- 1 1� Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: fr'l � (f a Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: _Cs I Project flame:Mgt( ?yam //�� , I Heat pump 61.06 f2 `G Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 / 7 Residential boiler(radiator or ,� L hydronic) 23.32 ma. Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: I Lot no.: Other. 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK 11 Gas fireplace/insert 33.39 Flue vent for water heater or gas // r'fili. fireplace 23.32 . Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 +., Other: 23.32 ❑ PROPER Y OWNE' ' Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 • Other: 23.32 • or�l Fuel piping: t Business name: /'3 a $14.15 for first four;$4.03 for each additional Contact name: (;t 4t / )L14' Furnace,etc. Address: . Gas heat pump _- WalUsuspended/unit heater City/State/ZIP: Water heater Phone:(03) �J S'/e7-7."- I Fax::( ) Fireplace _ Range E-mail: f O / /1l� 1 i� J Levi. Barbecue x Clothes dryer(gas) 1 Business name: LA 6-..'- Other: 14 Address: f/) y��� -1 / Subtotal City/State/ZIP: v 7 N,p�e. ��� f/�S Minimum permit fee($90.00) Phone:( �) �/ Fax: Plan review(25%of permit fee) �tJ3 d t e,,„�' ( ) State surcharge(12%of permit fee) CCB lic.: /1 1 7, TOTAL PERMIT FEE /5 ..9,la/ / ! This permit application expires if a permit is not obtain within 180 days after it has been accepted as complete. Authorized signature: 7 t_./i.---1 • Fee methodology set by Tri-County Building Industry Service Board Print name: �� !� jr/ Date: fj 11Building\Permits\MEC_PerniitApp_040113Ldoe 61 (11/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Famil Fee Schedule: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 O HAC CCB # 172126 scone of Work RECEIVEP Oregon Heating and Air Conditioning will perform the following scope of work: AUG 3 2015 i 1. Ducting and air distribution modifications as drawn. CITYOFTIGAitli BURIN G DIVISI01k.— <� ,,-t L-J , ■ Equipment Schedule vy 1 ou ' �� VAV- Existing variable volume boxes. Exterior with reheat. co �� in 1 64 3 I C SCI �--I Ventilation Requirements- based on 2014 OMSC table 403.3 II fr i` 1 - - No change-existing office on VAV - Omit L _ 4 y < ti • . Mechanical General Notes: N (n O 1. All steel ducting will be 26 ga minimum galvanized. Flex per Mfg. 2. Heating and cooling ducting to be designed to not exceed 0.5 wc positive(supply) and 0.5 wc negative(return). i 0 S. 3. Seal ducting with UL listed mastic or mastic tape. (0 0)j 1 I L____:_t 7/7- ,, .. i v 194ipip __, 1 A , . . , , , . . . - _ i O at, __ v r cf- _.. R . - ' - - __ _ —.� ._� : -_._. ....i.�af ..��..� —- -.-'mod. r \ / I- —I t A 1 l>< HVAC SUPPLY a IV1yl 1 ( I/ f / , <, - = -- —IV h "±fr I Ii � � 1 ‘v1 ( 1 I.: 1 I l HVAC RETURN Ivl il �i 4-7 7 -5 _IIcI . F.77.--,.- - i ! lA A ; 1 i r��� I .., i if_ 1 r I 1 r—Th L - ,,_ TP: I . .-- ..• . • ''..- r I I-Oregon Heating & A/C, Inc. PHONE NUMBERS MAILING ADDRESS OPERATIONS CONTRACTOR LICENSE C "' 503-691-9699 PO Box 241 ' 41 1930- _.,- SW 118" .Ave Oregon CCB 172126 503-691-8556(Fax) Dundee,OR 97115 Tualatin,OR 97062 Washington OREGOHC900BN www.oregonheating.com M 1 L OHAC CCB # 172126 Scope of Work RECEIVE!) Oregon Heating and Air Conditioning will perform the following scope of work: AUG 3 2015 1. Ducting and air distribution modifications as drawn. CITYOFTIGAKU • . • — _ - i- BUDDING DIVISI tom .� I ;� ,� _ ■ Equipment Schedule " VAV- Existing variable volume boxes. Exterior with reheat. . . - ........ It z in ,, I c - ! I� Ventilation Requirements- based on 2014 OMSC table 403.3 Ct I a) No change-existing office on VAV i /� f= . ~ k. G Mechanical General Notes: -0 cr ate alikrir., I I 1. All steel ducting will be 26 ga minimum galvanized. Flex per Mfg. J _ . _ _ ______- _ - 2. Heating and cooling ducting to be designed to not exceed 0.5 wc positive(supply) and 0.5 wc negative(return). . 0 '� �� t ��, ` 3. Seal ducting with UL listed mastic or mastic tape. v C d)• -I— Nx1- a I —.�— o u) r, _ p - [ i- i� ._ Tom` `:E colipG4M1 J • i _ © 1 CO + �.� i % % I N CD 4L.f c9 Ofex _ 1 , ___ . _ ■ ___J- ear /.. f `� l I HVAC SUPPLY 1- - n r ^ _n � f I Ii -,\ /.�.._... , 1 w ( /11' I r HVAC RETURN 1 r, III 1-— . 011, fii--- - _. _ ,_ - 1 \ 4 I, ._ _._ i ° Oregon Heating & A/C. Inc. : PHONE NUMBERS MAILING ADDRESS OPERATIONS CONTRACTOR LICENSE !' X7:7 503-691-9699 PO Box 241 19300 SW 118th Ave Oregon CCB 172126 - r 503-691-8556(Fax) Dundee,OR 97115 Tualatin, OR 97062 Washington OREGOHC900BN www.oregonheating corn M I Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 9020 SW WASHINGTON SQUARE RD 550, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2015-00523 George Heimos Violation Summary: Inspector Contractor