Report McTZait / eô / 6y
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, leoe 44€256/0€25X/0 , am the general contractor or the owner-builder
at the following address:
Site Address: 5-61) seg_v6e
city: a-O
Permit#: ool z-f--,O N V
Subdivision/Lot#: /2j c
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature:
1,4
„,`► Date:
Ge-- . Contractor or Owner-Builder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: /(I._ )/ f Jurisdiction: / 6-4p /a
Site Address: 092o J�c 5j �-l/Q/4 , ,C� Cam.
Subdivision/Lot#: PP/- re_ /At7f-(7-C'
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: Date: —
O eneral ontractor/Authorized lent
Print Name: fi
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfticiencyLighting.doc 07/01/08
a Form 6405 -01-31
CertificatIon—Site Inspection
New Ho mes Program—Single Family EnergyTrust
To be completed by Verifier of Oregon
Portland Energy Conservation,Inc.(PECI)is•Propriety Management Contractor for Energy Trust of Oregon.Inc.
Payment Infonrratlon II1Mti FOR EPS SHEET
Incentive Payee Company Name: I Performance Insulation I Is this payment redirected',: I No REQUIRED FOR QA/QC
Builder or Company. Wantland Industries 'Contact Name III IF HOUSE HAS COMPONENT
Verifier Payee Company Name. Performance Insulation Technician Name: 'fames hays. IF HOUSE HAS ADDITIONAL R VALUES
Energy Trust Pathway: Low Income No doesn't meet Low Income requirements
Incentive:
Solar Ready Solar Ready
Builder Incentive: Nan Verifier Incentive: Nora
Site lotonnaRlan
Development: 'Spruce 'Lot Axis ID'. I 'REM/RateP:ID
Address: 8820 SW Spruce St
Apt/Suite (Custom Home City I Tigard !Slate IOR Zip 97223
Unattached 'Number of Stories: 3 Total conditioned area 12.852 'soft 'e of BRs 14
Foundation Type. Crewlapace
Electric Provider: Portland General Electric Gas Provider: NW N.Wral
Solar installed None Solar Installer Name/Company:
Electric Meter Number I must be permanent meter number): Gas Meter Number(must be permanent meter number)
32 822 702 90585022
Verification Type Actual Modal JEquipment Details d Note.
Insulation Flat Ceiling R. Insulation Type Blown-in
Framing Type. Above Grade Wall R. Insulation Type Blown-in
Intermediate
Frame R-
Insulation Type Batts
Doors Door R-
Window. Windows U- SHGC:0.3
Skylights U- SHGC
Window Area(Glaring) % Total window area'.
Lighting Indoor and Outdoor % 0 Fixtures:141 it ENERGY STAR fixtures or CFLs: 115 36.5854
Appliances ENERGY STAR Diswasher Yes EF. Model#
Cooling Air Conditioning SEER Btu/Hr.
Primary Heat Source/Type. AFUE Brand Lennox
Source HSPF Model 0 tg9s060atOmp11 b
SEER Serial it W 1H4072008
Comment. COP:
Location =3 Outdoor Unit for heat pumps)
ECM: No Model ti
Serial et-
Water Heelsr Type EF #Brand. Ri 5r-r _ -_---
Gas EF: Model rI75i reu-vc252(dfud-us
Location Conditioned Serial#: FL CA-130545
Ventilation
Energy Trust of Oregon's Mechanical Ventilation on Ventlation Type Meets Energy Trust Mechanical Ventilation Requirements, Yee System
Requirement
Ethan! HRV/ERV Model#.
Ducts Ducts Inside: No %ducts inside. 50.0
Ducts in Conditioned Space Ducts Insulation: 8.0 Duct Seal w/Mastic 'Yen
If claiming incentive for ducts Inside,check one of the following: 'Duds Tested 159.12
EXH.FAN(t 48 CFM
Panormanoe Ten- r&Duet ,_W 705 BD
Duct Leakage Whole House Air Changes per
(CFM)@ 50Pa: Leakage Hour(ACHI C' House Volume. 23073
50Pa: 23072A Volume
1.83336 ACH
Notes:
Insulation Details
6=11galiall =NM
112171; 11111 1=1EM
111;112. Iri=M
Appliances
MIIIM
Rerraaaeralor % Model
Clods Washer MU' Mode.
Dryer X Model: