Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT N £ ' COMMUNITY DEVELOPMENT Permit#: FPS2015-00119 T!GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/30/2015 Parcel: 1S136DCO2504 Jurisdiction: Tigard Site address: 7297 SW DARTMOUTH ST Project: Party Fair Subdivision: FRUITLAND ACRES Lot: 16 Project Description: Adding(2)sprinkler heads for TI. Affidavit submitted. Contractor: WYATT FIRE PROTECTION INC. Owner: AMERICAN INDUSTRIES INC 9095 SW BURNHAM 1750 NW FRONT AVE STE#106 TIGARD,OR 97223 PORTLAND,OR 97209 PHONE: 503-684-2928 PHONE: FAX: 503-684-9657 FEES Description Date Amount Specifics: Permit Fee-COM 07/30/2015 $64.54 12%State Surcharge-Building 07/30/2015 $7.74 Type of Use: COM Plan Review-Fire Life Safety-COM 07/30/2015 $25.82 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 07/30/2015 $3.00 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: No Hazard: LT Density: .10 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $101.10 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $975.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow t' des adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-0.1-0090. Yo obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: mittee Signature: L ' - T`� A Ai A Airy Call 50 .• 9.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until compteti• of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System RECEIVED Received FOR OFFICE USE ONLY City of Tigard MAW Date/B .L Permit No.: is-. f. • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Is 7— Phone: 503.718.2439 Fax: 503.598.1960 JUL 3 0 2015 Date/B . Other Permit: t ; ,9O` • a. i 1P I I( A It 1) Inspection Line: 503.639.4175 Date Ready/By: ® See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: Supplemental Information BUILDING DIVISION TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING El New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation:1-and 2-family dwellin g ®Commercial/industrial $ El Accessory building ❑Multi-family Number of bedrooms: 111 Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:7297 SW Dartmouth St New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Party Fair Dartmouth Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Add fire sprinklers for TI Valuation: $$975.00 Existing building area: square feet New building area: 0 square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: 1 Name: Type of construction: IIIB Address: Occupancy groups: City/State/ZIP: Existing: Light Phone:( ) Fax:( ) New: APPLICANT CO CONTACT PERSON NOTICE Business name:Wyatt Fire Protection All contractors and subcontractors are required to be Contact name:Ashley Payne licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:9095 SW Burnham Rd jurisdiction in which work is being performed.If the City/State/ZIP:Tigard,OR 97223 applicant is exempt from licensing,the following reasons apply: Phone:(503)684-2928 Fax: :( E-mail:a.payne @wyattfire.com CONTRACTOR BUILDING PERMIT FEES* Business name:Wyatt Fire Protection (Please refer to fee schedule Permit fee: Address: City/State/ZIP: State surcharge(12%of permit fee): FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application.) CCB lie.:64077 Total permit fees: //ti J Authorized signature: Amount received: This permit application expires es if a permit is not obtained Print name:Ashley Payne Date:7/15/15 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:Building PennitsJPS-PevnitApp.doc Rev 01/05,2012 440-4613T(I I.02/COM/W EB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ® Addition ® 1-10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: 2 Additional description of work: • Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ® Wet ❑ Dry Additional Standpipes 0 Information: Hazard Group Light Density 0.10 Design Area 1500 K. Factor 5.6 l5 Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component El Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal(see A,B &C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage(see D above): $ State Surcharge(12%of permit fee): $ FLS Plan Review (40%of permit fee): $ TOTAL: $ Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. C:\Users\Ashley\Desktop\Permit Applications\Tigard App.doc Rev 01/05/2012 2 City of Tigard RECEIVED PermitNo.: F P J t5 -cool . • 13125 SW Hall Blvd.,Tigard,OR 97223 JUL 3 0 2015 Phone: 503.718.2439 Fax: 503.598.1960 Date Received: 7�?d`6-- I C A It i) Inspection Line: 503.639.4175 �- Internet: www.tigard-or.gov CITY OF TIGARD By: oA4,f,4„ / v9- BUILDING DIVISION FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: Party Fair Occupancy: Light Job Address: 7297 SW Dartmouth St Type of Construction: IIIB Suite: Contractor: Wyatt Fire Protection Phone: 503-684-2928 Number of Proposed or Altered Heads: 2 Type: SSP Hazard: Light Density: 0.10 I, Ashley Payne, Wyatt Fire Protection Oregon Construction Contractors Board No. 64077 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits, beams, partitions, walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop (exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads (see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: itr -/ Date: 7/15/2015 Print Name: Ashley Payne I:\Building\Forms\FireSprinklerAffidavit_071514.docx Page 1 of I Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 7297 SW DARTMOUTH ST, TIGARD, OR, 97223 Commercial - Fire Protection System 999 Sprinkler final PASS - No C of O FPS2015-00119 Chip Barnett Violation Summary: Inspector Contractor