Loading...
Plans 48'-0" Sign Face ` EL NOTES Equal 12'-6" 12'-6" 12-6" Equal C 1) Contractor is res onsible to verif all field conditions a m (upright s acin �, P Y and existing E E spacing) member sizes as detailed on this drawing. Upon completion, the sign N J V 1 G 2014 structure shall be in compliance with all aspects of this drawing. Contractor is also responsible to notify Engineer of any discrepancies CITY 01-116411) found. III Rear Catwalk (exist.) 9iJr l tki niiimor 2) Existing knee braces are to be removed. I § .§ - 3) Add new 400 watt metal halide lights (4 req'd/face) � I g Stringers Existing ^ Lv (4 exist./face) CITY Op TIGARD 14' x 48' Centermount x 3 I REVIEWED FOR CODE COMPLIANCE GENERAL NOTES Back to Back Sign Structure I * i��Rear Catwalk (exist) Approved: f`4 • ALL NUTS AND BOLTS ARE TO BE ZINC PLATED. (except A-490 bolts, which are QTC:. — �t— ll— not to be plated, but primed and painted after installation) I J _ • THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN FEU) BEFORE Permit#: (� 2 I✓� � FABRICATION OR CONSTRUCTION, AND NOTIFY ENGINEER OF ANY DISCREPANCIES _ i • ANY DEVIATIONS FROM THIS PRINT MUST BE APPROVED BY ENGINEER. 'III Address: �d( J D C. `- • STRUCTURAL STEEL SHAPES d: PLATES SHALL CONFORM TO THE REQUIREMENTS OF / C12 x 30 Reinf. 20'd x .250" A.S.T.M. A-36 and WIDE FLANGES TO A.S.T.M. A992. Apron \\\ I / / Channels (2 exist.) 1 Torsion Pipe Suite#: (except shucturol tubing, which shall conform to A-500, grade B) N / / I (exist.) Front Catwalk (exist) By: -, ) (r3ftd,_I ( ) y �' DatNcS ALL STEEL PIPE SHALL CONFORM TO THE REQUIREMENTS OF A.S.T.M. A-53, GRADE B a OR A-252, GRADE 2; UNLESS OTHERWISE NOTED. 1 )= \.\ //I/� ,� I • ALL STRUCTURAL STEEL SHALL BE PRODUCED, FABRICATED, AN ERECTED IN ACCORDANCE TO THE LATEST A.I.S.C. SPECIFICATIONS AND STANDARD PRACTICES. / / —jam- ALL WELDING SHALL BE IN ACCORDANCE WITH A.W.S. STANDARDS. WELDING TO BE Add new 400 \\ I /i/ Remow existing P_— OFF CE COPY PEORMED BY CERTIFIED WELDERS U�NG E-70 ELECTRODES. metal halide hb • CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH aF Fe = 3000 p s 1. (4 req d/face) as — — / ! IN 28 DAYS, UNLESS OTHERWISE NOTED. I • CONTRACTOR TO ENSURE THAT ALL WORK IS PERFORMED IN ACCORDANCE WITH I — — FEDERAL, STATE, d LOCAL CODES I ORDINANCES; AND O.S.H.A. SAFETY REGULATIONS. • VERIFY WITH OWNER AU.SIGN HEAD ACCESS REQUIREMENTS. (i.e. COLUMN &ACCESS I I LADDER(S), CROSSOVER/WALK—AROUND CATWALKS, ect..) • VERIFY CORRECT STRINGER SPACING WITH OWNER PRIOR TO FABRICATION. iL— -- —it I I • H A GA = Height Above Ground Level F 1: APPLICABLE BUILDING CODE AND WIND SPEED: 36'0 x .600" 2009 I.B.C. (90 mph — Exp. C) Column Pipe (exist.) o 1 Effective Engineering Solutions, LTD. 61 White Water Court I I I I New Lenox, IL 60451 -4 (815) 485-1470 PROJECT: Knee Brace Removal/Light Addition on a 14' x 48' N Centermount Structure 0 60'-0" Overall Height 42"I x .500" 11 x L J Column Pipe CLIENT: exact I I I I LAMAR — Eugene #407 c '� •s, THIS PRINT CONTAINS PROPRIETARY INFORMATION AND SHALL NOT BE < C `9� USED, REPRODUCED, OR ITS CONTENTS DISCLOSED, IN WHOLE OR IN I It PART, WITHOUT WRITTEN CONSENT FROM THE ABOVE CLIENT. CL. — THE UNDERSIGNED ENGINEER WILL NOT SUPERVISE THE FABRICATION AND ERECTION OF ae E. a iN / N I ( ) AFFIX SEAL ft..E P�� LOCATION:j 1 ,d� TION. V 0 �; N w`Q �r‘ 138 ele it"-:- Panel Panel #3006 CL [ ) T Tigard, OR Q ±� Front Elevation ,c, Catwalk 1 N Catwalk CANON ENGINEERED BY:wai W6 x 9 !edger II r W6 "9 Ledger t j� `'4at 16� '�y CWL ,:'h,, T7, DRAWN BY: