Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT III g ' COMMUNITY DEVELOPMENT Permit#: FPS2015-00109 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/16/2015 Parcel: 2S 112AA00400 Jurisdiction: Tigard Site address: 14280 SW 72ND AVE Project: Leifs Autobody Subdivision: MILLMONT PARK Lot: 49 Project Description: Installing(1)pendent sprinkler head. Affidavit submitted. Contractor: DELTA FIRE INC Owner: ICON OWNER POOL 1 WEST LLC 14795 SW 72ND AVE BY RYAN PORTLAND,OR 97224 PO BOX 460169 HOUSTON,TX 77056 PHONE: 503-620-4020 PHONE. FAX: 503-620-1058 FEES Description Date Amount Specifics: Permit Fee-COM 07/16/2015 $56.47 12%State Surcharge-Building 07/16/2015 $6.78 Type of Use: COM Plan Review-Fire Life Safety-COM 07/16/2015 $22.59 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 07/16/2015 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: .10 Design Area: 1500 K Factor: 5.62 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Gales Provided: Cut Sheets Required: Total $86.34 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $694.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or g.'' . 44. Issued By: •. ittee Signature: Call 503.6 175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Fire Protection System Building Permit Application FOR OFFICE USE ONLY City of Tigard BC CEP ED Received �m Permit No.: —aa 13125 SW Hall Blvd.,Tigard,OR 97 BE Plan Review Phone: 503.639.4171 Fax: 503.598.1960 6 2015 Date/B : Other Permit: I I c,A It I) Inspection Line: 503.639.4175 �UL 1 Date Ready/By: Juris: See Page 2 for Internet: www.tigard-or.gov Y M1,..10 Notified/Method: .7�.c Supplemental Information GTv ri._ TYPE OF } D;lv°-a 1-J o,t.,'v REQUIRED DATA: 1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 3 Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling j Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 14280 SW 72nd Ave. New dwelling area: square feet City/State/ZIP: Tigard, OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Leif s Auto Collision TI Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Install Sprinkler Pendent for existing room in building with valuation: $694.00 existing fire protection that did not have a sprinkler previously. _ Existing building area: square feet New building area: square feet PROPERTY OWNER ❑ TENANT Number of stories: Name: Leif s Auto Collison Type of construction: Address: 14280 SW 72nd Ave. Occupancy groups: City/State/ZIP: Tigard, OR 97224 Existing: Phone:( ) Fax:( ) New: ❑ APPLICANT ❑ CONTACT PERSON NOTICE Business name:Delta Fire, Inc. All contractors and subcontractors are required to be Contact name: Heidi Scarbrough licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 14795 SW 72nd Ave. jurisdiction in which work is being performed.If the City/State/ZIP: applicant is exempt from licensing,the following reasons Portland, OR 97224 apply: Phone:( 503) 620-4020 Fax::( 503)620-1058 E-mail: heidis @deltafire.com CONTRACTOR BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Delta Fire, Inc. Permit fee: Address: 14795 SW 72nd Ave. State surcharge(8%of permit fee): City/State/ZIP: Portland, OR 97224 FLS plan review(40%of permit fee): Phone:(503)620-4020 Fax:( 503) 620-1058 (Due upon application.) CCB lic.: 64174 Total permit fees: O(P,_ / '��// Amount received: ,t)..()( Authorized signature: (I,rl �l This permit application expires if a permit is not obtained Print name: Heidi Scarbrough Date: 7-16-15 Within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:/BuildingPennits'FPS-PermitApp.doc 03/23/06 440-4613T(II/02!COM-WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ® 1-10 heads: No plan review required. ® Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: 1 Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ® Wet ❑ 1)r■ Additional Standpipes N/A Information: Hazard Group Light Density 0.10 Design Area 1500 K. Factor 5.62 Sprinkler Project Valuation: $694.00 B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: _ $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A,B&C above): $ Permit fee based on project valuation(see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (8%of permit fee): $ FLS Plan Review(40% of permit fee): $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New"fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer,or NICET level"3"technicians. I:1Building\Permits\PPS-PezmitApp.doc 03/23/06 440.4613T(11/02/COM/WEB) City of Tigard ECE,!a' ) Permit No.: P'S 01-0 r S— 9 • 13125 SW Hall Blvd.,Tigard,OR 972 3 r Qd(� 1,1 Phone: 503.718.2439 Fax: 503.598.1960 1 1 6 2015 Date Received: 7/b/i s Inspection Line: 503.639.4175 JUL T I G n I.Il Internet: www.tigard-or.gov OF TIGARO By: ,�e$' CITY r��.f4i�i G DIVISION FIRE SPRIW AFFIDAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: Leif's Auto Collision TI Occupancy: Job Address: 14280 SW 72nd Ave. Type of Construction: Suite: Contractor: Delta Fire, Inc. Phone: 503-620-4020 Number of Proposed or Altered Heads: 1 Type: Hazard: Light Density: 0.10 1 Heidi Scarbrough Oregon Construction Contractors Board No. 64174 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits, beams,partitions, walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop (exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this documei t with a copy of the sketch attached shall be available for all inspections. Signature: ; Date: 7'16-15 Print Name: Heidi Scarbrough / I:\Building\Forms\FireSprinklerAffidavit_071514.docx Page 1 of 1 I 4.e ■•••74 ,.................„..7‹ 1 r 1 N• , . , _ .___ ,......____...._._14k • 4 0/1 PIPING PLAN SCALE-h-.1'-0" ADD SPRINKLER TO EXISTING ROOM SPRINKLER TO BE SUPPLIED BY EXISTING FIRE SPRINKLER SYSTEM 2'X 1"MECH.TEE 1"X AS REQ. �1, ..__w....1AREAOFWOR •• �_ ,� EXISTING 2"PIPE f o .t NO MORE THAN 1 > c.:. ca '°:"""" SPRINKLER TO BE SUPPLIED BY MECH. a X T / EE a ,,,, 1"X%R.C.400 " .. ,..... - SSP �_n r - DROP DETAIL KEY PLAN SCALE-N.T.S. SCALE-N.T.S. SYM. TYPE MFG.IMOOEL SINE TEMP. SIZE FINISH CANOPY FINISH QTY. LEI F'S • SSP RELIABLE Fl iRS6 RA1414 15SF •1/2 CHROME AEC CHROME 1 AUTO COLLISION DELT 14280 SW 72ND AVE,TIGARD OR 97224 FIRE,INC. TITLE COMPUTER ROOM SPRINKLER 71 FIRE PROTECTION CONTRACTORS DATE 7/18 2013 SCALE 1/S" 1'-0" SHEET 1 OF 1 tnse 9w.12ro.PORnun.oR 9722" 190)120.W20 CONT. 15-5475 DRWM. MG SYSTEM VET