Structural Modification Report
116' Monopole
Prepared for:
Crown Castle
BU No. 874140
Progress
Verizon Wireless
CITY OF TIGARD
SPECIAL INSPECTION REQUIRED REVIEWED a'OR CODE COMPLIANCE
State of Oregon Structural Specialty Qode
B roject Nub i L
❑ Concrete and Reinforcing Steel 7 875.003.01/wroth# 1:30>240(.7._— 'C»C-72_.-
0 Bolts Installed in Co rx;rete Address: lQ(e5- U)C
❑ Special Moment-Resisting Concrete Frame Suite#
P Steel Tendon A ri 1 8, 2015By= ,�C% Data ,2" [C�"
❑ ,��oing SNeI ii<Prestressing[i�.�;tnicturai Waking
❑ "Iglu-strenght Bolting
OFFICE COPY
❑ Structural Masonry
❑ Reinforced Gypsum Concrete
❑ Insulating Concrete Fill B+T G R P
❑ Spray Applied Fire-Resistive Materials
0 Pilings,Drilled Piers and Caissons g T Group
❑ Shotcrete 1717 S. B ulder, Suite 300
❑ Special Grading,Excavation and Filling Tuls , OK 74119
❑ Smoke-Control Systems (91 1)3 587-4630
ModDw s @btgrp.com
❑ other Inspections
• dip B+T GRP
• April 8, 2015
Mr. Paul Anzini B+T Group
Crown Castle 1717 S. Boulder, Suite 300
5350 North 48th Street, Suite 305 Tulsa, OK 74119
Chandler, AZ 85226 (918) 587-4630
(602) 845-1753 ModDwgs @btgrp.com
Subject: Structural Modification Report
Carrier Designation: Verizon Wireless Co-Locate
Carrier Site Number: N/A
Carrier Site Name: POR Cascade
Crown Castle Designation: Crown Castle BU Number: 874140
Crown Castle Site Name: Progress
Crown Castle JDE Job Number: 326369
Crown Castle Work Order Number: 1033165
Crown Castle Application Number: 285805 Rev. 3
- Engineering Firm Designation: B+T Group Project Number: 78875.003.01
Site Data: 10185 SW Cascade Avenue, Portland, OR, Washington County
Latitude 45°26'48.46", Longitude -122°47'2.41"
116 Foot-Monopole
Dear Mr. Anzini,
B+T Group is pleased to submit this "Structural Modification Report" to determine the structural integrity of
the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural
`Statement of Work' and the terms of Crown Castle Purchase Order Number 770428, in accordance with
application 285805, revision 3.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC4.5: TSA specified load case with proposed modifications Sufficient Capacity
Note:See Table 1 and Table 2 for the proposed and existing loading,respectively.
The analysis has been performed in accordance with the 2012 International Building Code based upon an
ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per
section 1609.3.1 as required for use in the TIA-222-G standard per Exception#5 of Section 1609.1.1. Exposure
Category C and Risk Category II were used in this analysis.
All modifications and equipment proposed in this report shall be installed in accordance with the attached
drawings for the determined available structural capacity to be effective.
We at B+T Group appreciate the opportunity of providing our continuing professional services to you, "Crown
Castle. If you have any questions or need further assistance on this or any other project,,:u-se Ji--' call.
Respectfully submitted by: , G
B+T Engineering, Inc. � `�9 �,r•
/ 9 69 6PE r"
.. /5
OREGON
Braden Tabb, E.I. Chad E. Tuttle, P.E. 414. 13, 24c�
Project Engineer President CHAD Tlf11\-4
tnxTower Report-version 6.1.4.1 fExpiratio � � -=-�l
April 8, 2015
116 Ft Monopole Structural Modification Report CCI BU No 874140
Project Number 78875.003.01, Application 285805, Revision 3 Page 2
TABLE OF CONTENTS
1) INTRODUCTION
2)ANALYSIS CRITERIA
Table 1 -Proposed Antenna and Cable Information
Table 2-Existing Antenna and Cable Information
Table 3-Design Antenna and Cable Information
3)ANALYSIS PROCEDURE
Table 4- Documents Provided
3.1)Analysis Method
3.2)Assumptions
4)ANALYSIS RESULTS
Table 5-Section Capacity (Summary)
Table 6-Tower Components vs. Capacity
4.1) Recommendations
5)APPENDIX A
tnxTower Output
6)APPENDIX B
Base Level Drawing
7)APPENDIX C
Additional Calculations
8)APPENDIX D
Tower Modification Drawings
tnxTower Report-version 6.1.4.1
April8, 2015
116 Ft Monopole Structural Modification Report CCI BU No 874140
Project Number 78875.003.01,Application 285805, Revision 3 Page 3
1) INTRODUCTION
This tower was originally a 100 ft. monopole designed by Valmont in December of 1995. The monopole was
originally designed for a wind speed of 85 mph per TIA/EIA-222-E. The monopole was later extended to 116 ft.
by Valmont in August of 2006.
2) ANALYSIS CRITERIA
The structural analysis was performed for this monopole in accordance with the requirements of TIA-222-G
Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind
speed of 93 mph with no ice, 30 mph with 1 inch ice thickness and 60 mph under service loads, exposure
category C.
Table 1 - Proposed Antenna and Cable Information
1 Center
Mounting Line Number Antenna Number Feed
of Antenna Model of Feed Line Note
Level (ft) Elevation Manufacturer
lft) Antennas Lines Size (in)
8 Amphenol WBX045T19X000
8 CSS ( X7C-FRO-840-V
4 Ericsson [ RRUS 12 B2
- 4 Ericsson I RRUS 12 B4
4 Ericsson RRUS A2 B13
75.0 75.0 4 1-1/4 —
4 Ericsson [ RRUS A2 B2
4 Ericsson RRUS A2 B4
4 Ericsson I RRUS B13
4 Raycap I RCMDC-3315-PF-48
1 I -- 1 Platform Mount[LP 301-1]
Table 2- Existing Antenna and Cable Information
Center Number Number Feed
Mounting Line of Antenna Antenna Model of Feed Line Note
Level (ft) Elevation Antennas Manufacturer Lines Size(in)
(ft)
114 0 j 117.0 l 1 l Axxcelera AB-ACCESS 6 1-5/8 ' 1
115.0 3 KMW Comm I HB-X-ID-19-65-00T 1 3/8
6 Andrew I ETW200VS12UB
3 Andrew I TMBX-6516-R2M
6 Andrew I TMBXX-6516-R2M
97.0 100.0 3 Nokia FRIG 1 1-1/4
I
2 Nokia FXFB
1 Raycap RNSDC-7771-PF-48
I 97.0 1 -- Platform Mount[LP 713-1]
I 87.0 2 Radiowaves I HP2-23
85.0 1 -- I Side Arm Mount[SO 103-3] 6 5/16
85.0 3 Kathrein I 840 10057 2 1/2
1
83.0
I 3 I Nextnet Wireless' BTS-2500
Notes:
1) Existing Equipment
tnxTower Report-version 6.1.4.1
April 8, 2015
116 Ft Monopole Structural Modification Report CCI BU No 874140
Project Number 78875.003.01, Application 285805, Revision 3 Page 4
Table 3 - Design Antenna and Cable Information
Center Number Number Feed
Mounting Line Antenna Antenna Model of Feed Line
Level (ft) Elevation Antennas Manufacturer Lines Size (in)
(ft)
97 97 1 Generic 1 Platform I -- --
12 DB978S 1
85 j 85 1 Generic 4' Dish I — --
75 75 �, 1 Generic Platform
9 Swedcom SP9014-DIN
-- —
50 50 1 Generic 4' Dish I
3)ANALYSIS PROCEDURE
Table 4- Documents Provided
1
Document Remarks I Reference I
I 111 Source
Online Application Verizon Wireless, Co-Locate Revision #3 285805 CCI Sites
Tower Manufacturer Drawings Valmont, Order No. 12317-95 1353528 CCI Sites]
Foundation Drawing Portland General Electric Co., Date: 03/04/96 1354428 CCI Sites
Geotect Report Northwest Geotech, Inc., Project No. 705.2.1 1353413 CCI Sites
Tower Modification Drawir-is—E Valmont, Order No. 19351-06 I 2248976 CCI Sites
Modification Inspection Report 1 TEP#061169 1956214 CCI Sites
Antenna Configuration Crown CAD Package rDate: 03/09/15 CCI Sites
3.1) Analysis Method
tnxTower(version 6.1.4.1), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer's specifications.
2) The tower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
4) Mount areas and weights are assumed based on photographs provided.
This analysis may be affected if any assumptions are not valid or have been made in error. B+T
Group should be notified to determine the effect on the structural integrity of the tower.
tnxTower Report-version 6.1.4.1
April 8, 2015
116 Ft Monopole Structural Modification Report CCI BU No 874140
Project Number 78875.003.01, Application 285805, Revision 3 Page 5
4) ANALYSIS RESULTS
Table 5 -Section Capacity (Summary) - LC4.5
Section Elevation(ft) Component Size Critical P(K) SF*P_allow °7° Pass I Fail
No. Type Element (K) Capacity
L1 116-100 Pole TP14.14x11.26x0.188 I 1 1 -0.622 - 10.4 Pass' 1
L2 100-67.5 Pole TP19.987x14.14x0.219 2 ( -9.843 - 1 87.6 1 Pass'
L3 i 67.5 51.083 Pole + TP22.94x19.987x0.631 3 -12.411 ' - 68.3 Pass' I
L4 1 51.083-32.25 Pole TP25.894x21.798x0.625 4 -18.374 - + 90.2 Pass'
L5 32.25-0 Pole TP31.7x25.894x0.655 ( 5 -27.664 - 94.9 i Pass'
I Summary l___ J
T- I Pole(L5) 94.9 I Pass'
•
- I I 1 T Rating= 94.9 Pass'
Table 6 -Tower Component Stresses vs. Capacity - LC4.5
Notes Component Elevation (ft) % Capacity Pass/ Fail
1 Flange Bolts 100 8.9 Pass
1 — j Flange Plate 100 1 6.6 Pass
1 I Anchor Rods Base I 91.5 Pass
1 Base Plate Base 61.4 Pass
1 Base Foundation Base 72.7 Pass
(Soil Interaction) f
•
1 Base Foundation Base 71.9 Pass I
(Steel)
Structure Rating (max from all components) = I 94.9%
Notes:
1) See additional documentation in"Appendix C-Additional Calculations"for calculations supporting the%capacity listed.
4.1) Recommendations
1) All modifications proposed in this report shall be installed in accordance with the attached
drawings (Appendix D) for the determined available structural capacity to be effective.
tnxTower Report-version 6.1.4.1
APPENDIX A
tnxTOWER OUTPUT
w
116.0e DESIGNED APPURTENANCE LOADING
TYPE ELEVATION TYPE ELEVATION
h Lightning Rod 518"x 6'(E) 119 BTS-2500(8) 85
ELEVATION
wl Mount 114 BTS-2500(E) 85
§ m g $ Pi Pe(E) BTS-2500(E) 85
6 "- Q f c HB-X-ID-19-65-007 wl Mount 114 6'x 2-1/2"Mount Pipe(E) 85
Pipe(E) 6 x 2-1/2" _.
Mount Pipe(E) 85
HB X•1619-65-0177 wl Mount 114 6•x 2-1/2"Mount Pipe(E) 85
Pipe(E)
AB-ACCESS(E) 114 ,.Side Arm Mount[SO 103-3j(E) 85
100.0 A (2)TMBXX-6516-R2M w/Mount 97 HP2.23(E) 85
Pipe(E) HP2-23(E) 85
liii (2)TMBXX-6516-R2M wl Mount 97 (2) x�`TI9X000(P) 75
Pipe(E) (2)X7C-FRO-840-V(P) 75
(2)TMBXX-6516-R2M w/Mount 97 (4)X7C-FRO-840-V w/Mount 75
RPe(E) PPe(p)
1 TMBX-6516-R2M w/Mount Pipe 97 (2)X7C-FRO-840-V(P) 75
(E) RRUS 12 B4(P) 75
TMBX-6516•R2M w/Mount Pipe 97 (2)RRUS 12 64(P) 75
(E) -RRUS 12 B4(P) 75
Q TMBX-6516-R2M w/Mount Pipe 97 RCMDC-3315-PF-48(P) 75
15
n V- N m R (E) (2)RCMDC•3315•PF-48(P) 75
ei o ' of (2)ETWZOOVSI2UB(E) 97 RCMDC-3315-PF-48(P) 75
(2)E7W200VS12UB(E) 97 RRUS A2 84(P) 75
(2)ETW200VS12UB(E) 97
FRIG(E) 97 (2)RRUS A2 94(P) 75
i" 1 I I FRIG(E) 97 RRUS A2 84(P) 75
'.�li l I' FRIG(E) 97 RRUS A2 813(P) 75
(2)G FXFB(E)(E) 97 (2)RRUS A2 B13(P) 75
I I I I RNSDC-7771-PF-48(E) 97 RRUS A2 913(P) 75
(4)8'x2"Mount Pipe(E) 97 RRUS B13(P) 75
(4)8'x2"Mount Pipe(E) 97 (2)RRUS B73(P) 75
67.511 RRUS B13(P) 75
(4)8'x2"Mount Pipe(E) 97
RRUS A2 82(FO 75
6'x2"Mount Pipe(E) 97
6'x2"Mount Pipe(E) 97 '(2)RRUS A2 B2(P) 75
6'x 2"Mount Pipe(E) 97 RRUS A2 82(P) 75
Platform Mount[LP 713-1)(E) 97 RRUS 12 132(P) 75
" ^ ° (2)RRUS 12 B2(P) 75
m a ^+ a,
Of or 7 840 10057 w/Mount Pipe(E-per 85
- `_° o io °•' r O Photo) RRUS 12 92(P) 75
840 10057 wl Mount Pipe(E-per 85 Platform Mount[LP 301-1](P-4 75
/ -
photo) per sector)
840 10057 w/Mount Pipe(E-per 85 (2)(�WBX045T79X000(P) 75
51.1 6 photo) (4)WBXO45T19X000(P) 75
Pi
MATERIAL STRENGTH
GRADE Fy Fu GRADE Fy Fu
ai
ei
A572-65 65 651 80 kai 40.064294ksi 40 ksi 55 Iasi
^ ,39.820679611 40 kal 55 ksi
40.86911 ksi 41 ksi 56 651
gi N m
Y � m r m
c4 M TOWER DESIGN NOTES
1. Tower is located in Washington County,Oregon.
2. Tower designed for Exposure C to the TIA-222-G Standard.
3. Tower designed for a 93 mph basic wind in accordance with the TIA-222-G
32.3 R Standard.
a 4. Tower is also designed for a 30 mph basic wind with 1.00 in ice.Ice is considered
to increase in thickness with height.
ALL REACTION:5. Deflections are based upon a 60 mph wind.
ARE FACTOREL6. Tower Structure Class II.
7. Topographic Category 1 with Crest Height of 0.000 ft
AXIAL 8. TOWER RATING:94.9%
65 K
SHEAR MOMENT
01 0 m $ +- ' 3 K ( J 237 kip-ft
g o 4 �, $ a:
3 TORQUE 1 kip-ft
30 mph WIND-1.000 in ICE
AXIAL
28 K
SHEAR I \ MOMENT
25 K ` 1862 kip-ft
. - 0.0 6 I
8 .4 TORQUE 6 kip-ft
v 5 REACTIONS-93 mph WIND
c `o n .3 - _ g
• 4 % a o a "
y
N fZ H N ifi° r$ g 3
F
�
- B+T Group Job.78875.003.01-Progress, OR(BLitt 874140)
1717 S. Boulder, Suite 300 project
cbent.Crown Castle Drawn b':SChougule App'd:
B*T Tulsa,OK 74119 Phone:(918)587-4630 Code: TIA-222-G Date:03/27/15 Scale' NTS
FAX:(91 B)587-4630 Path: „,,,,.. ..... a®,.............m....n p p Dwg 1411 E_1
f
TIA-222-G -93 mph/30 mph 1.000 in Ice Exposure C Maximum Values
Vx -Vz - Mx - Mz
1-
Global Mast Shear(K) Global Mast Moment(kip-ft)
0 5 10 15 20 25 0 500 1000 1500 2000
116.O1,..: 116.000
100.000 + _i�___�__F�_- +_- -�+�- -4_+-I-4___ti 4_�.____�__+_�__+_1-� 100.000
Iri
1
(
I
l
1
I
I
I
I
I
- 67.50( +-1_1-+__I-+-I-1- 4--44__I-4__I -I_1-+-I_ 67.500
...
C
0
W
CD
W 51.08 _51.083
32.25C 32.250
I
11
1
1
I •
{pi{
.\
I1 I,.
0.000 :I
0.000
0 5 10 15 20 25 0 500 1000 1500 2000
t B+T Group Job 78875.003.01-Progress, OR(BU#874140)
1717 S. Boulder,Suite 300 P"*"1.:
Tulsa, OK 74119 °Ib°1.Crown Castle Drawn by:SChougule APO':
Phone:(918)587-4630 code: TIA-222-G Date:03/27/15 scale: NTS
FAX.(918)587-4630 Path:
.ws,..R.,.,-.n. .. ca 1.6,5.,.14.0. . t.t. m DwgNO.E-4
TIA-222-G - Service - 60 mph Maximum Values
Deflection (in) Tilt (deg) Twist(deg)
0 5 10 15 20 25 0 0.5 1 1.5 2 0 0.05 0.1
118.000 I I 116.000
■ i I [ III I I I I I I I I I 1 I (I I I I I I
IIII II1 II1 111 I I 1 I I I I
III 1111 II1 I II I I I I I I I
IIII III 1111 1 II I I I I 1 1 1
1111 IIII IIII I II I I I I I I I
IIII IIII IIII I II I I I I I I I
IIII IIII IIII I II I I I I I I I
1°1°-°C 1----- - 1 1 1 4_I- I----I-I-I_ 1 1
II I I I I I I I I I I I I I I I I I I 100.000
IIII III IIII I I I I I I I I 1
1111 II1 IIII 1 I I I l I 1 1 1
1111 II1 IIII III I I 1 I 1 1 1
1111 1111 IIII IIII I I I I 11 1
II II IIII IIII IIII I I I I 1 1 1
II II IIII IIII IIII I I 1 1
II II IIII IIII IIII I I I I I 1
II II 1111 III IIII 1 1 1 1 I I I
III I IIII III III I I I I I I I I
III I IIII IIII III I I I I I I I I
III I IIII II 1 III I I I I I I I I I
III 1 IIII IIII III I I I I I I I I I
III I IIII I II III I I I I I I I I I
II I I I II I II I I I I I I I I I I I
III I IIII IIII III I I I I I I I I
IIII IIII III III I I I I I I I I
87. LL--JJ -I- 4 -1-1-1-1-----I.1_ _L1J-I__L11J_ 1_1_11--1-LL1_ _I__i_-L_1____ __I_-I-- _ 57.500
IIII II1 IIII III I 1 1 1 I I I
de. 1111 1111 IIII III I I I I I I I
.� III I 1111 IIII III I I I I I I 1
C 0
III I 1111 IIII III I I I I I I I I
i+ III I III IIII III I I I I I I I
a II II III IIII III I I I I I I I I
m 1111 1111 1111 1111 I I I I I I I
W 51.088 I I I I I I I I I I I I 1 1 1 1 I I I 1 1 1
rr -1-1'17-7 -rrrr---17- -r 11-i--rt '1--rrT1--I-rri- T--I--r-7
III II 1 1111 1111 1 1 1 1 1 1
Ill 1111 IIit III I 1 1 1 I I
111 1 II 1111 1111 I I I I 1 1 1
111 I II 1111 1111 I I I I I I I
III I 1111 1111 1111 I I I 1 1 1
111 1111 1111 1111 1 1 1 1 1 1 1
III III 1111 1111 I I I I 1 1 1
111 IIll 1111 1111 1 I I 1 1 1 1
32.25C1 I I I I I I 1 1 1 I I 1 1 I 11 I I I I I I I 1 32 250
IIII II1 II1 IIII I I I I I I 1
IIII II1 II1 IIII I I I I I I
IIII 1111 IIII 1111 I 1 I I
III IIII II1 1111 I I 1 1
IIII III IIII IIII I I I I I I
IIII II1 II1 IIII 1 1 1 1 1 1
II I II1 1111 III I 1 1 1 1
II 1 II1 III III I 1 1 1
IIII IIII IIII III I I I I I I I I
II IIII IIII III I I . 1 I
II 1111 1111 III I I I I I I I I I
IIII IIII IIII III I I I I I
IIII IIII IIII III I I I I I I
III IIII IIII 1111 I I I I I I I I
. IIII IIII IIII III I I I I I I I I I
IIII IIII 1111 III I I I I I I I I
a I I 1 1 I I I I 1 1 1 1 1 1 1 1 1_ I I I I I I 0.000
0 5 10 15 20 25 0 0.5 1 1.5 2 0 0.05 0.1
B+T Group 10°
� 78875.003.01-Progress, OR(BU#874140)
j� 1717 S. Boulder,Suite 300 Pnc1:
B.T GRr' Tulsa,OK 74119 Gam'Crown Castle Drawn nY:SChougule APP'd`
Phone:(918)587-4830 Cod°'TIA-222-G Date:03/27115 scale: NTS
FAX:(918)587-4830 Path: Dwq No E-5
Feed Line Distribution Chart
0' - 116'
Round Flat app In Pace App Out Face. ,• Truss Leg
1•
116 00o Face A Face B Face C 116.000
114.000 I 114.000
I
I
100.000 I 100.000
97.000 • 97.000
I F •
ii 1
I I I
f r 85.000 85.000
I I I •
I I I
_ I I 75000 I 75.000 I I I
I I I I I I
I _ _ 70.000 L 70.000 ` • • •
I
_ 67500 __ _I I I
__ ____ .__ _ 87.500
I I I I I I
a I I 1
I I I
Z. I I M 1 • c g s
I
al M
LL d h 81 d d
tuI WI LL E 0. I I I N LL LL
W 51.063 Co- _-�.� _ 7 51.083
r I I IP 1 o1 of
. . . ..
�I $ I . 1 e � p� 0
n aN
_ o
- 1I ml
I I I �I -IKI
N • 4• g,•
-- I I -`i� -- 35.000 I 35.000 1-gi-gl
32.250 . • • • 32.250
I I I
I I I I I I 2 2
a I LL
LL
I I I I I a 0.
LL LL LL
I I I I I I
N N N N
I I u I u I
U U
I 1 I I I I
1 1 I I I 1
0.000 I I I I I I _ 0.000
m- B+T Group ° 78875.003.01 Progress, OR(BU#874140)
j 1717 S. Boulder,Suite 300 Project
13-T cr;t, Tulsa,OK 74119 Chen`Crown Castle Drawn by:SChougule App'd
Phone:(918)587-4630 Code: TIA-222-G Date:03/27/15 Scale: NTS
FAX:(918)587-4630 Path: Dwg NO.E-7
Job Page
tnx owes 78875.003.01 - Progress, OR (BU#874140) 1 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)587-4630 SChougule
Tower Input Data
There is a pole section.
This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Tower is located in Washington County,Oregon.
Basic wind speed of 93 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0.000 ft.
Nominal ice thickness of 1.000 in.
Ice thickness is considered to increase with height.
Ice density of 56.000 pcf.
A wind speed of 30 mph is used in combination with ice.
Temperature drop of 50.000°F.
Deflections calculated using a wind speed of 60 mph.
A non-linear(P-delta)analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not
considered.
Tapered Pole Section Geometry
Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade
Length Length of Diameter Diameter Thickness Radius
ft ft ft Sides in in in in
L 1 116.000-100.00 16.000 0.000 12 11.260 14.140 0.188 0.750 A572-65
0 (65 ksi)
L2 100.000-67.500 32.500 0.000 12 14.140 19.987 0.219 0.875 A572-65
(65 ksi)
L3 67.500-51.083 16.417 3.917 12 19.987 22.940 0.631 2.524 39.820679ksi
(40 ksi)
L4 51.083-32.250 22.750 0.000 12 21.798 25.894 0.625 2.501 40.064294ksi
(40 ksi)
L5 32.250-0.000 32.250 12 25.894 31.700 0.655 2.619 40.86911ksi
(41 ksi)
Tapered Pole Properties
Section Tip Dia. Area I r C 1/C J It/Q w wit
in in2 in4 in in in3 in' i in
LI 11.657 6.685 104.612 3.964 5.833 17.935 211.972 3.290 2.515 13.414
14.639 8.424 209.314 4.995 7.325 28.577 424.128 4.146 3.287 17.531
L2 14.639 9.806 242.563 4.984 7.325 33.117 491.498 4.826 3.203 14.644
20.692 13.924 694.498 7.077 10.353 67.081 1407.240 6.853 4.770 21.806
L3 20.692 39.328 1880.628 6.929 10.353 181.649 3810.663 19.356 3.665 5.809
23.749 45.329 2879.526 7.987 11.883 242.325 5834.699 22.310 4.457 7.063
IA 23.297 42.634 2439.414 7.580 11.291 216.044 4942.914 20.983 4.166 6.662
26.807 50.882 4146.694 9.046 13.413 309.156 8402.326 25.042 5.264 8.417
L5 26.807 53.215 4326.774 9.036 13.413 322.582 8767.218 26.191 5.185 7.918
32.818 65.458 8052.570 11.114 16.421 490.394 16316.690 32.216 6.741 10.294
Page
m xT ower Job 78875.003.01 -Progress, OR(BU#874140) 2 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle SChougule
FAX.(918)587-4630 I
• Tower Gusset Gusset Gusset Grade Adjust.Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness A/ Factor Stitch Bolt Stitch Bolt
(per face) A, Spacing Spacing
Diagonals Horizontals
ft ftz in in in
LI 1 1 1
116.000-100.0
00
L2 1 1 1
100.000-67.50
0
L3 I 1 0.898781
67.500-51.083
L4 1 1 0.925865
51.083-32.250
L5 1 1 0.929768
- 32.250-0.000
r Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Component Placement Total Number Start/End Width or Perimeter Weight
Type Number Per Row Position Diameter
ft in in klf
LDF7-50A(1-5/8") A Surface Ar 114.000-0.000 6 6 0.000 1.980 0.001
(E) (CaAa) 0.350
RFA 1206-24S26-}X!Q{(1-1/4") A Surface Ar 75.000-0.000 4 4 -0.250 1.310 0.001
(P) (CaAa) -0.050
Safety Line 3/8 C Surface Ar 116.000-0.000 1 1 0.000 0.375 0.000
(E) (CaAa) 0.000
as @ss
CCI-1.25"x6.5"-FP A Surface Af 35.000-0.000 1 1 0.000 6.500 15.500 0.000
(P-Mod) (CaAa) 0.000
CCI-1.25"x6.5"-FP B Surface Af 35.000-0.000 1 1 -0.250 6.500 15.500 0.000
(P-Mod) (CaAa) -0.250
CCI-1.25"x6.5"-FP C Surface Af 35.000-0.000 I 1 -0.500 6.500 15.500 0.000
(P-Mod) (CaAa) -0.500
CCI-1.25"x6.5"-FP C Surface Af 35.000-0.000 1 1 0.250 6.500 15.500 0.000
(P-Mod) (CaAa) 0.250
rf
CCI-1"x6"-FP A Surface Af 70.000-35.000 I 1 0.000 6.000 14.000 0.000
(P-Mod) (CaAa) 0.000
CCI-1"x6"-FP B Surface Af 70.000-35.000 I 1 -0.250 6.000 14.000 0.000
(P-Mod) (CaAa) -0.250
CCI-1"x6"-FP C Surface Af 70.000-35.000 I 1 -0.500 6.000 14.000 0.000
(P-Mod) (CaAa) -0.500
CCI-1"x6"-FP C Surface Af 70.000-35.000 I 1 0.250 6.000 14.000 0.000
(P-Mod) (CaAa) 0.250
•r @.•
c.
Pa ge
tnxTower 78875.003.01 -Progress, OR(BU#874140) 3 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)587-4630 SChougule
Feed Line/Linear Appurtenances - Entered As Area
Description Face Allow Component Placement Total C4A;1 Weight
or Shield Type Number
Leg ft le/ft klf
LDF2-50(3/8") B No Inside Pole 114.000-0.000 1 No Ice 0.000 0.000
(E) 1/2"Ice 0.000 0.000
1"Ice 0.000 0.000
LDF5-50A(7/8") A No Inside Pole 97.000-0.000 18 No Ice 0.000 0.000
(E) 1/2"Ice 0.000 0.000
1"Ice 0.000 0.000
ASU9323TYP01(1-1/4) A No Inside Pole 97.000-0.000 1 No Ice 0.000 0.001
(E) 1/2"Ice 0.000 0.001
1"Ice 0.000 0.001
......s
2"Rigid Conduit C No Inside Pole 85.000-0.000 3 No Ice 0.000 0.003
(E) 1/2"Ice 0.000 0.003
1"Ice 0.000 0.003
. LDF4-50A(1/2") C No Inside Pole 85.000-0.000 2 No Ice 0.000 0.000
(E(Inside Conduit)) 1/2"Ice 0.000 0.000
1"Ice 0.000 0.000
9207(5/16") C No Inside Pole 85.000-0.000 6 No Ice 0.000 0.001
(E(Inside Conduit)) 1/2"Ice 0.000 0.001
1"Ice 0.000 0.001
..@a.
Feed Line/Linear Appurtenances Section Areas
Tower Tower Face AR AF CAAA CAAA Weight
Section Elevation In Face Out Face
ft ft2 ftz fie le K
LI 116.000-100.000 A 0.000 0.000 16.632 0.000 0.069
B 0.000 0.000 0.000 0.000 0.001
C 0.000 0.000 0.600 0.000 0.004
L2 100.000-67.500 A 0.000 0.000 45.040 0.000 0.410
B 0.000 0.000 2.500 0.000 0.003
C 0.000 0.000 6.219 0.000 0.222
L3 67.500-51.083 A 0.000 0.000 44.523 0.000 0.293
B 0.000 0.000 16.417 0.000 0.001
C 0.000 0.000 33.450 0.000 0.206
L4 51.083-32.250 A 0.000 0.000 51.304 0.000 0.336
B 0.000 0.000 19.062 0.000 0.002
C 0.000 0.000 38.831 0.000 0.236
L5 32.250-0.000 A 0.000 0.000 90.150 0.000 0.575
B 0.000 0.000 34.938 0.000 0.003
C 0.000 0.000 71.084 0.000 0.404
Feed Line/Linear Appurtenances Section Areas - With Ice
Tower Tower Face Ice AR AF CAAA C.4A_4 Weight
Section Elevation or Thickness In Face Out Face
ft Leg in fr2 ft' fig ft1 K
LI 116.000-100.000 A 2.251 0.000 0.000 28.669 0.000 0.497
B 0.000 0.000 0.000 0.000 0.001
C 0.000 0.000 7.804 0.000 0.119
Pa
tnxTower 78875.003.01 -Progress, OR(BU#874140) Page
4 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)587-4630 SChougule
Tower Tower Face Ice AR AF CAAA CAAA Weight
Section Elevation or Thickness In Face Out Face
ft Leg in ft2 ft' ft' fi2 K
L2 100.000-67.500 A 2.193 0.000 0.000 78.704 0.000 1.547
B 0.000 0.000 3.597 0.000 0.050
C 0.000 0.000 22.668 0.000 0.541
L3 67.500-51.083 A 2.120 0.000 0.000 75.912 0.000 1.319
B 0.000 0.000 23.378 0.000 0.299
C 0.000 0.000 54.332 0.000 0.908
L4 51.083-32.250 A 2.046 0.000 0.000 87.313 0.000 1.517
B 0.000 0.000 27.047 0.000 0.347
C 0.000 0.000 62.786 0.000 1.048
L5 32.250-0.000 A 1.860 0.000 0.000 145.944 0.000 2.326
B 0.000 0.000 46.935 0.000 0.528
C 0.000 0.000 107.077 0.000 1.619
Feed Line Center of Pressure
Section Elevation CP1 CPz CP.- Cl',
-
Ice Ice
ft in in in in
LI 116.000-100.000 -0.559 -0.662 -0.470 .0401
L2 100.000-67.500 -0.689 -0.781 -0.638 -0.538
L3 67.500-51.083 -0.609 -0.865 -0.646 -0.710
LA 51.083-32.250 -0.660 -0.943 -0.709 -0.783
L5 32.250-0.000 -0.727 -1.068 -0.801 -0.921
Shielding Factor Ka
Tower Feed Line Description Feed Line Ka K„
Section Record No. Segment Elev. No Ice Ice
LI 2 LDF7-50A(1-5/8") 100.00- 1.0000 1.0000
114.00
L 1 13 Safety Line 3/8 100.00- 1.0000 1.0000
116.00
L2 2 LDF7-50A(1-5/8") 67.50-100.00 1.0000 1.0000
L2 11 RFA1206-24S26-XXX(1-1/4 67.50-75.00 1.0000 1.0000
")
L2 13 Safety Line 3/8 67.50-100.00 1.0000 1.0000
L2 20 CCI-1"x6"-FP 67.50-70.00 1.0000 1.0000
L2 21 CCI-1"x6"-FP 67.50-70.00 1.0000 1.0000
L2 22 CCI-1"x6"-FP 67.50-70.00 1.0000 1.0000
L2 23 CCI-1"x6"-FP 67.50-70.00 1.0000 1.0000
L3 2 LDF7-50A(1-5/8") 51.08-67.50 1.0000 1.0000
L3 11 RFA 1206-24526-XXX(1-1/4 51.08-67.50 1.0000 1.0000
")
L3 13 Safety Line 3/8 51.08-67.50 1.0000 1.0000
L3 20 CCI-1"x6"-FP 51.08-67.50 1.0000 1.0000
L3 21 CCI-1"x6"-FP 51.08-67.50 1.0000 1.0000
L3 22 CCI-1"x6"-FP 51.08-67.50 1.0000 1.0000
L3 23 CCI-1"x6"-FP 51.08-67.50 1.0000 1.0000
L3 15 CCI-1.25"x6.5"-FP 51.08-35.00 1.0000 1.0000
L3 16 CCI-1.25"x6.5"-FP 51.08-35.00 1.0000 1.0000
L3 17 CCI-1.25"x6.5"-FP 51.08-35.00 1.0000 1.0000
L3 18 CCI-1.25"x6.5"-FP 51.08-35.00 1.0000 1.0000
L5 2 LDF7-50A(1-5/8") 0.00-32.25 1.0000 1.0000
L5 11 RFA 1206-24S26-XXX(1-1/4 0.00-32.25 1.0000 1.0000
")
k
Page
Pa g
tnxTower Jo 78875.003.01 - Progress, OR (BU#874140) 5 of 10
B+T Group Project Date
17175 Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX(918)587-4630 SChougule
Tower Feed Line Description Feed Line ' K. A,
Section Record No. Segment Elev. No Ice Ice
L5 13 Safety Line 3/8 0.00-32.25 1.0000 1.0000
L5 15 CCI-1.25"x6.5"-FP 0.00-32.25 1.0000 1.0000
L5 16 CCI-1.25"x6.5"-FP 0.00-32.25 1.0000 1.0000
L5 17 CCI-1.25"x6.5"-FP 0.00-32.25 1.0000 1.0000
L5 18 CCI-1.25"x6.5"-FP 0.00-32.25 1.0000 1.0000
Discrete Tower Loads
Description Face Offset Offsets: Azimuth Placement CAA CAA Weight
or Type Hor_ Adjustment Front Side
Leg Lateral
Vert
ft 0 ft fl= ft' K
ft
ft
Lightning Rod 5/8"x 6' C None 0.000 119.000 No Ice 0.375 0.375 0.033
_ (E) 1/2"Ice 0.989 0.989 0.037
I"Ice 1.619 1.619 0.045
*******
HB-X-ID-19-65-00T w/ A From Leg 1.000 0.000 114.000 No Ice 4.519 4.519 0.051
Mount Pipe 0.000 1/2"Ice 5.425 5.425 0.094
(E) 1.000 1"Ice 6.210 6.210 0.144
HB-X-ID-19-65-00T w/ B From Leg 1.000 0.000 114.000 No Ice 4.519 4.519 0.051
Mount Pipe 0.000 1/2"Ice 5.425 5.425 0.094
(E) 1.000 1"Ice 6.210 6.210 0.144
HB-X-ID-19-65-00T w/ C From Leg 1.000 0.000 114.000 No Ice 4.519 4.519 0.051
Mount Pipe 0.000 1/2"Ice 5.425 5.425 0.094
(E) 1.000 1"Ice 6.210 6.210 0.144
AB-ACCESS B From Leg 1.000 0.000 114.000 No Ice 1.944 0.622 0.011
(E) 0.000 1/2"Ice 2.143 0.777 0.022
3.000 1"Ice 2.351 0.940 0.035
(2)TMBXX-6516-R2M w/ A From Leg 4.000 0.000 97.000 No Ice 6.176 4.525 0.054
Mount Pipe 0.000 1/2"Ice 6.655 5.205 0.103
(E) 3.000 1"Ice 7.137 5.899 0.158
(2)TMBXX-6516-R2M w/ B From Leg 4.000 0.000 97.000 No Ice 6.176 4.525 0.054
Mount Pipe 0.000 1/2"Ice 6.655 5.205 0.103
(E) 3.000 1"Ice 7.137 5.899 0.158
(2)TMBXX-6516-R2M w/ C From Leg 4.000 0.000 97.000 No Ice 6.176 4.525 0.054
Mount Pipe 0.000 1/2"Ice 6.655 5.205 0.103
(E) 3.000 1"Ice 7.137 5.899 0.158
TMBX-6516-R2M w/Mount A From Leg 4.000 0.000 97.000 No Ice 3.598 3.241 0.030
Pipe 0.000 1/2"Ice 3.998 3.914 0.064
(E) 3.000 1"Ice 4.435 4.564 0.103
TMBX-6516-R2M w/Mount B From Leg 4.000 0.000 97.000 No Ice 3.598 3.241 0.030
Pipe 0.000 1/2"Ice 3.998 3.914 0.064
(E) 3.000 1"Ice 4.435 4.564 0.103
TMBX-6516-R2M w/Mount C From Leg 4.000 0.000 97.000 No Ice 3.598 3.241 0.030
Pipe 0.000 1/2"Ice 3.998 3.914 0.064
(E) 3.000 1"Ice 4.435 4.564 0.103
(2)ETW200VS12UB A From Leg 4.000 0.000 97.000 No Ice 0.184 0.472 0.011
(E) 0.000 1/2"Ice 0.248 0.567 0.015
3.000 1"Ice 0.322 0.670 0.019
(2)ETW200VS 12UB B From Leg 4.000 0.000 97.000 No Ice 0.184 0.472 0.011
(E) 0.000 1/2"Ice 0.248 0.567 0.015
3.000 1"Ice 0.322 0.670 0.019
(2)ETW200VS 12UB C From Leg 4.000 0.000 97.000 No Ice 0.184 0.472 0.011
(E) 0.000 1/2"Ice 0.248 0.567 0.015
3.000 1"Ice 0.322 0.670 0.019
s
ilL
Page
_
tnxTower Jib g 78875.003.01 - Progress, OR (BU#874140) 6 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)587-4630 SChougUle
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Hon Adjustment Front Side
Leg Lateral
Vert
ft ft fie ft' K
ft
ft
FRIG A From Leg 4.000 0.000 97.000 No Ice 2.793 1.103 0.057
(E) 0.000 l'Ice 3.018 1.268 0.075
3.000 1"Ice 3.252 1.443 0.095
FRIG B From Leg 4.000 0.000 97.000 No Ice 2.793 1.103 0.057
(E) 0.000 1/2"Ice 3.018 1.268 0.075
3.000 1"Ice 3.252 1.443 0.095
FRIG C From Leg 4.000 0.000 97.000 No Ice 2.793 1.103 0.057
(E) 0.000 1/2"Ice 3.018 1.268 0.075
3.000 I"Ice 3.252 1.443 0.095
(2)FXFB A From Leg 4.000 0.000 97.000 No Ice 4.128 1.123 0.055
(E) 0.000 1/2"Ice 4.400 1.304 0.077
3.000 1"Ice 4.681 1.493 0.103
RNSDC-7771-PF-48 A From Leg 4.000 0.000 97.000 No Ice 3.708 1.376 0.020
(E) 0.000 1/2"Ice 3.965 1.557 0.043
3.000 1"Ice 4.231 1.746 0.069
(4)6'x 2"Mount Pipe A From Leg 4.000 0.000 97.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
(4)6'x 2"Mount Pipe B From Leg 4.000 0.000 97.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
(4)6'x 2"Mount Pipe C From Leg 4.000 0.000 97.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
6'x 2"Mount Pipe A From Leg 4.000 0.000 97.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
3.000 1"Ice 2.294 2.294 0.048
6'x 2"Mount Pipe B From Leg 4.000 0.000 97.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
3.000 1"Ice 2.294 2.294 0.048
6'x 2"Mount Pipe C From Leg 4.000 0.000 97.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
3.000 1"Ice 2.294 2.294 0.048
Platform Mount[LP 713-1] C None 0.000 97.000 No Ice 31.270 31.270 1.510
(E) 1/2"Ice 39.680 39.680 1.929
1"Ice 48.090 48.090 2.348
•sss*ss
840 10057 w/Mount Pipe A From Leg 2.000 0.000 85.000 No Ice 2.718 2.351 0.026
(E-per photo) 0.000 1/2"Ice 3.095 2.883 0.053
-2.000 1"Ice 3.483 3.431 0.084
840 10057 w/Mount Pipe B From Leg 2.000 0.000 85.000 No Ice 2.718 2.351 0.026
(E-per photo) 0.000 1/2"Ice 3.095 2.883 0.053
-2.000 I"Ice 3.483 3.431 0.084
840 10057 w/Mount Pipe C From Leg 2.000 0.000 85.000 No Ice 2.718 2.351 0.026
(E-per photo) 0.000 1/2"Ice 3.095 2.883 0.053
-2.000 1"Ice 3.483 3.431 0.084
BTS-2500 A From Leg 2.000 0.000 85.000 No Ice 2.120 0.957 0.035
(E) 0.000 1/2"Ice 2.323 1.119 0.048
-2.000 1"Ice 2.534 1.291 0.064
BTS-2500 B From Leg 2.000 0.000 85.000 No Ice 2.120 0.957 0.035
(E) 0.000 1/2"Ice 2.323 1.119 0.048
-2.000 1"Ice 2.534 1.291 0.064
BTS-2500 C From Leg 2.000 0.000 85.000 No Ice 2.120 0.957 0.035
(E) 0.000 1/2"Ice 2.323 1.119 0.048
-2.000 1"Ice 2.534 1.291 0.064
6'x 2-1/2"Mount Pipe A From Leg 2.000 0.000 85.000 No Ice 1.725 1.725 0.035
(E) 0.000 1/2"Ice 2.088 2.088 0.047
Job e
g Pa
tnxTower 78875.003.01 - Progress, OR (BU#874140) 7 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)587-4630 SChougule
Description Face Offset Offsets: A:imuth Placement CAAA CAAA Weight
or Type Harz Adjustment Front Side
Leg Lateral
Vert
ft ft ft' ft' K
ft
f
0.000 1"Ice 2.460 2.460 0.064
6'x 2-1/2"Mount Pipe B From Leg 2.000 0.000 85.000 No Ice 1.725 1.725 0.035
(E) 0.000 1/2"Ice 2.088 2.088 0.047
0.000 1"Ice 2.460 2.460 0.064
6'x 2-1/2"Mount Pipe C From Leg 2.000 0.000 85.000 No Ice 1.725 1.725 0.035
(E) 0.000 1/2"Ice 2.088 2.088 0.047
0.000 1"Ice 2.460 2.460 0.064
Side Arm Mount[SO 103-3] C None 0.000 85.000 No Ice 9.500 9.500 0.224
(E) 1/2"Ice 11.800 11.800 0.317
1"Ice 14.100 14.100 0.410
s•ssssr
(2)WBX045T19X000 A From Leg 4.000 0.000 75.000 No Ice 7.996 0.576 0.037
(P) 0.000 1/2"Ice 8.437 0.708 0.074
0.000 1"Ice 8.887 0.848 0.116
(4)WBX045T19X000 B From Leg 4.000 0.000 75.000 No Ice 7.996 0.576 0.037
(P) 0.000 1/2"Ice 8.437 0.708 0.074
0.000 I"Ice 8.887 0.848 0.116
(2)WBX045T19X000 C From Leg 4.000 0.000 75.000 No Ice 7.996 0.576 0.037
(P) 0.000 1/2"Ice 8.437 0.708 0.074
0.000 1"Ice 8.887 0.848 0.116
(2)X7C-FRO-840-V A From Leg 4.000 0.000 75.000 No Ice 17.267 9.056 0.057
(P) 0.000 1/2"Ice 18.013 9.655 0.152
0.000 I"Ice 18.768 10.263 0.255
(4)X7C-FRO-840-V w/ B From Leg 4.000 0.000 75.000 No Ice 17.504 11.193 0.090
Mount Pipe 0.000 1/2"Ice 18.354 12.721 0.208
(P) 0.000 I"Ice 19.214 14.273 0.337
(2)X7C-FRO-840-V C From Leg 4.000 0.000 75.000 No Ice 17.267 9.056 0.057
(P) 0.000 1/2"Ice 18.013 9.655 0.152
0.000 I"Ice 18.768 10.263 0.255
RRUS 12 B4 A From Leg 4.000 0.000 75.000 No Ice 3.667 1.483 0.049
(P) 0.000 1/2"Ice 3.924 1.668 0.073
0.000 1"Ice 4.189 1.861 0.099
(2)RRUS 12 B4 B From Leg 4.000 0.000 75.000 No Ice 3.667 1.483 0.049
(P) 0.000 1/2"Ice 3.924 1.668 0.073
0.000 1"Ice 4.189 1.861 0.099
RRUS 12 B4 C From Leg 4.000 0.000 75.000 No Ice 3.667 1.483 0.049
(P) 0.000 1/2"Ice 3.924 1.668 0.073
0.000 1"Ice 4.189 1.861 0.099
RCMDC-3315-PF-48 A From Leg 4.000 0.000 75.000 No Ice 4.326 2.557 0.032
(P) 0.000 1/2"Ice 4.609 2.794 0.062
0.000 1"Ice 4.901 3.040 0.097
(2)RCMDC-3315-PF-48 B From Leg 4.000 0.000 75.000 No Ice 4.326 2.557 0.032
(P) 0.000 1/2"Ice 4.609 2.794 0.062
0.000 1"Ice 4.901 3.040 0.097
RCMDC-3315-PF-48 C From Leg 4.000 0.000 75.000 No Ice 4.326 2.557 0.032
(P) 0.000 1/2"Ice 4.609 2.794 0.062
0.000 1"Ice 4.901 3.040 0.097
RRUS A2 B4 A From Leg 4.000 0.000 75.000 No Ice 2.562 0.578 0.022
•
(P) 0.000 1/2"Ice 2.777 0.716 0.035
0.000 1"Ice 3.000 0.861 0.051
(2)RRUS A2 B4 B From Leg 4.000 0.000 75.000 No Ice 2.562 0.578 0.022
(P) 0.000 1/2"Ice 2.777 0.716 0.035
0.000 1"Ice 3.000 0.861 0.051
RRUS A2 B4 C From Leg 4.000 0.000 75.000 No Ice 2.562 0.578 0.022
(P) 0.000 1/2"Ice 2.777 0.716 0.035
0.000 1"Ice 3.000 0.861 0.051
RRUS A2 B13 A From Leg 4.000 0.000 75.000 No Ice 3.256 2.011 0.075
I
Job Page
tarTower 78875.003.01 -Progress, OR (BU#874140) 8 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle SChou ule
FAX:(918)587-4630 9
Description Face Offset Offsets: Azimuth Placement CAAA CiA., Weight
or Type Hor_ Adjustment Front Side
Leg Lateral
Vert
ft ° ft fry ft' K
ft
ft
(P) 0.000 1/2"Ice 3.498 2.211 0.100
0.000 1"Ice 3.749 2.420 0.128
(2)RRUS A2 B13 B From Leg 4.000 0.000 75.000 No Ice 3.256 2.011 0.075
(13) 0.000 1/2"Ice 3.498 2.211 0.100
0.000 1"Ice 3.749 2.420 0.128
RRUS A2 B13 C From Leg 4.000 0.000 75.000 No Ice 3.256 2.011 0.075
(P) 0.000 1/2"Ice 3.498 2.211 0.100
0.000 1"Ice 3.749 2.420 0.128
RRUS B13 A From Leg 4.000 0.000 75.000 No Ice 3.256 1.379 0.051
(P) 0.000 1/2"Ice 3.498 1.558 0.072
0.000 1"Ice 3.749 1.745 0.096
(2)RRUS B13 B From Leg 4.000 0.000 75.000 No Ice 3.256 1.379 0.051
(P) 0.000 1/2"Ice 3.498 1.558 0.072
0.000 1"Ice 3.749 1.745 0.096
RRUS B13 C From Leg 4,000 0.000 75.000 No Ice 3.256 1.379 0.051
(P) 0.000 1/2"Ice 3.498 1.558 0.072
0.000 1"Ice 3.749 1.745 0.096
RRUS A2 B2 A From Leg 4.000 0.000 75.000 No Ice 2.562 0.578 0.022
(P) 0.000 1/2"Ice 2.777 0.716 0.035
0.000 1"Ice 3.000 0.861 0.051
(2)RRUS A2 B2 B From Leg 4.000 0.000 75.000 No Ice 2.562 0.578 0.022
(P) 0.000 1/2"Ice 2.777 0.716 0.035
0.000 1"Ice 3.000 0.861 0.051
RRUS A2 B2 C From Leg 4.000 0.000 75.000 No Ice 2.562 0.578 0.022
(P) 0.000 1/2"Ice 2.777 0.716 0.035
0.000 1"Ice 3.000 0.861 0.051
RRUS 12 B2 A From Leg 4.000 0.000 75.000 No Ice 3.667 1.483 0.049
(P) 0.000 1/2"Ice 3.924 1.668 0.073
0.000 1"Ice 4.189 1.861 0.099
(2)RRUS 12 B2 B From Leg 4.000 0.000 75.000 No Ice 3.667 1.483 0.049
(P) 0.000 1/2"Ice 3.924 1.668 0.073
0.000 1"Ice 4.189 1.861 0.099
RRUS 12 B2 C From Leg 4.000 0.000 75.000 No Ice 3.667 1.483 0.049
(P) 0.000 1/2"Ice 3.924 1.668 0.073
0.000 1"Ice 4.189 1.861 0.099
Platform Mount[LP 301-1] C None 0.000 75.000 No Ice 30.100 30.100 1.589
(P-4 M.P per sector) 1/2"Ice 40.800 40.800 2.029
I"Ice 51.500 51.500 2.470
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horn Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft ° ft ft fiz K
I1P2-23 B Paraboloid From 2.000 40.000 85.000 2.042 No Ice 3.274 0.027
(E) w/Shroud(HP) Leg 0.000 1/2"Ice 3.547 0.045
2.000 1"Ice 3.819 0.063
HP2-23 C Paraboloid From 2.000 90.000 85.000 2.042 No Ice 3.274 0.027
(E) w/Shroud(HP) Leg 0.000 1/2"Ice 3.547 0.045
2.000 1"Ice 3.819 0.063
Pa
tilxTower 78875.003.01 - Progress, OR (BU#874140) Page
9 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)587-4630 SChougUle
Compression Checks
Pole Design Data
Section Elevation Size I. E. KI/r A P„ OP„ Ratio
No. P.
ft ft ft in' K K 4IP„
LI 116-100(1) TPI4.14x11.26x0.188 16.000 0.000 0.0 8.424 -0.622 620.920 0.001
L2 100-67.5(2) TPI9.987x14.14x0.219 32.500 0.000 0.0 13.924 -9.843 1014.200 0.010
L3 67.5-51.083 TP22.94x19.987x0.631 16.417 0.000 0.0 43.897 -12.411 1982.250 0.006
(3)
L4 51.083-32.25 TP25.894x21.798x0.625 22.750 0.000 0.0 50.882 -18.374 2311.700 0.008
(4)
L5 32.25-0(5) TP31.7x25.894x0.655 32.250 0.000 0.0 65.457 -27.664 3033.670 0.009
Pole Bending Design Data
Section Elevation Size M. 0M Ratio M 4M,,,. Ratio
No. M. Mo,
ft lap ft 16P ft 4M lap-f bp-ft GM,,,.
LI 116-100(1) TPI4.14x11.26x0.188 18.150 175.536 0.103 0.000 175.536 0.000
L2 100-67.5(2) TP19.987x14.14x0.219 354.057 407.174 0.870 0.000 407.174 0.000
L3 67.5-51.083 TP22.94x19.987x0.631 603.983 854.417 0.707 0.000 854.417 0.000
(3)
LA 51.083-32.25 TP25.894x21.798x0.625 1093.700 1170.492 0.934 0.000 1170.492 0.000
(4)
L5 32.25-0(5) TP31.7x25.894x0.655 1861.567 1893.967 0.983 0.000 1893.967 0.000
Pole Shear Design Data
Section Elevation Size Actual 4V„ Ratio Actual $T„ Ratio
No. V, V 7u T„_
ft K K sV kV-ft IaP-f 07;
LI 116-100(I) TP14.14x11.26x0.188 1.653 310.460 0.005 0.016 355.932 0.000
L2 100-67.5(2) TPI9.987x14.14x0.219 19.532 507.101 0.039 3.144 825.622 0.004
L3 67.5-51.083 TP22.94x19.987x0.631 20.645 991.124 0.021 0.181 1732.492 0.000
(3)
L4 51.083-32.25 TP25.894x21.798x0.625 22.372 1155.850 0.019 0.180 2373.383 0.000
(4)
L5 32.25-0(5) TP31.7x25.894x0.655 25.375 1516.830 0.017 5.519 3840.375 0.001
Job Page
m xTower 78875.003.01 -Progress, OR (BU#874140) 10 of 10
B+T Group Project Date
1717 S.Boulder,Suite 300 18:04:38 03/27/15
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle SChou ule
FAX:(918)587-4630 g
Pole Interaction Design Data
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. P. M. M y V. T Stress Stress
ft $P„ OM.,, 4M,,. OK, 4T Ratio Ratio
LI 116-100(1) 0.001 0.103 0.000 0.005 0.000 0.104 1.000
4.8/
V
L2 100-67.5(2) 0.010 0.870 0.000 0.039 0.004 0.881 1.000
4.8/ ✓
V
L3 67.5-51.083 0.006 0.707 0.000 0.021 0.000 0.714 1.000
4.8/ V
(3) ✓
L4 51.083-32.25 0.008 0.934 0.000 0.019 0.000 0.943 1.000 482 ✓
(4) ✓
L5 32.25-0(5) 0.009 0.983 0.000 0.017 0.001 0.992 1.000 482 V
_ ✓
Section Capacity Table
Section Elevation Component See Critical P oPdu„ % Pass
No. .t Type Element K K Capacity Fail
LI 116-100 Pole TPI4.14x11.26x0.188 I -0.622 620.920 10.4 Pass
L2 100-67.5 Pole TP19.987x14.14x0.219 2 -9.843 1014.200 87.6 Pass
L3 67.5-51.083 Pole TP22.94x19.987x0.631 3 -12.411 1982.250 68.3 Pass
L4 51.083-32.25 Pole TP25.894x21.798x0.625 4 -18.374 2311.700 90.2 Pass
L5 32.25-0 Pole TP31.7x25.894x0.655 5 -27.664 3033.670 94.9 Pass
Summary
Pole(L5) 94.9 Pass
RATING- 94.9 Pass
Program Version 6.1.4.1-12/18/2013 File:78875_003_01_Progress_OR_Modified.eri
APPENDIX B
BASE LEVEL DRAWING
(INSTALLED)
(6) 1-5/8' TO 114 FT LEVEL -
(PROPO1%D)TO 75 FT LEVEL l -_A.1 r
O
OO • 4
(INSTALLED) {. ---(1) 1-1/4'TO 97 FT LEVEL I \
- (18) 7/8' TO 97 FT LEVEL \
N
_ / / \ • LEVEL/ 3/8' TO 114 FT EL
/ / \
I I oR I I
I o`� o�' I I
1 \ / /
\ \
� � _ � � / /
N //
® (INSTALLED-BUNDLED IN (3) 2 CONDUITS)
(8) 5/16'TO 85 FT LEVEL
(2) 1/2' TO 85 FT LEVEL
BUSINESS UNIT: 874140
- APPENDIX C
ADDITIONAL CALCULATIONS
1111T.A11111"00,S01006«.:,NFEtreamcammAamalsziammanamammariam.vmasanumcmaanzamix. 131021•7=1.1..J',AM..MMIMMISMY...-MMI.MM,ALtUNIIILLINIIILUM•04MILMMOMEILIMMLMMIIMMZEMEZIMMILMULIMIMIMMXIMNISMJI+,,MM.=
1111LUMVA.MV00,X011.,,It MUMMIAML.:1:1••itill IIILIZMUMLUALLNIMMISLOILIWIM.1111.1A1114111.1MIC.MIIC.M....71auMnaMMME4MLIMIlitilLINIIIIIMICILZMILLUAR
111AVAINS ,10.11,4.0.:-ALIIIICSINIMILIMMLM.....1[MCWANNIMMIIMELLIMMIMM= IMMIGINIMIAMMILMIKI111111KIIMMEIMMIMMUNIMOINIE'LMILUMIntilfillIIMII.JIM.I.MMIMItiuMIX4M ' , 10-1.M.1
wir:2,ztzt, 11PAIIMIEMIKIEMMEMIMIMME111 .1MLE.417,111MOIMIKLAIMISMIMLIMMIIIMCIMCIMIISUIN 7 PICA fl Sa1anfl. rna
'1161.1111M,1:.W.g.,:eleM:.073msamilummtamaamem■■■■•■■■er.agamitanimmonsmaimmimamuccEmmuumsasizmaawssuaLF,ammarammummaciumaeuantimoummlicomm•znamarzonimmanwannuamass
1111a3310 , W.:.1.-"ElliMIIIIELNIINZI/11111111•111=11.■•■,lel■■■■■111W1,nEi.g.=.14MMEM11.171•Z•1114M1•1111L91ALMILi.l.M#1,leM11.111VAIMEM.L_MUMILLIMW,WEIcilettIMIIERINIMLINISeE54•11, ====.71MIMEMIEIM
AlliiiIN11111.1111111111111111111111111111111111111111111111110111111111111111.111.111101111110101111.11181111111iliblibliMilliN10110111111111111111111110111111E111101111
P043...1,141a.Paia Pu•
,,saorrovosav
ssans alodl...1°1•11
.
Reins Flats(Used for relative orientation only.Actual flat numbers may vary.)
Bottom Top Qty Model Position T or T&C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
0 32.25 4 CI-1.25x6.5 F T&C *, � v
32.25 67.5 4 CCI-1x6 F T&C � n 1�.
F T&C
F T&C *s,
F T&C
F T&C
F T&C
F T&C
F T&C r."I.�.€ :, ,,N
Rein2
Bottom Top Qty Model Position T or T&C
0 F T&C ,. p
F T&C
F T&C s do- 't ��1.
Rein3
Bottom Top Qty Model Position T or T&C
0 F T&C :'
F T&C �#
R.
is
F T&C ` s ,
F T&C �'
F T&Cf
F T&C t
F T&C ,,.__.-.L......:,;'_„. .. . ". a.
•
•
Reinforcement Capbcity a
( Ar eroSdufions�.LCP
�/ SSoo Flalirom Parkw,v,was 100
Booklet,co eons
720,301,6962
Dimensions and Properties Compression Axial
i i 1 1 i ASD-9 LRFD
■
Centroid Centroid Allowable
from from Bolt Web Flange Hole Sender. Slender. Axial w/ Design Axial
Weight Moment of MOmentOf Mating Edge HoleCenter Thickness Flange Thickness Diameter Yield Stress Ultimate Ratio Unbraced Ratio Unbracen Allowable i� Governing Strength Governing
Model moo Area(As') Inertia(in')I Inertia(in) kin) (in) (in) Width fin) Width(in) (in) (in) (15i) Stress(ksi) Coefficient Length(in) Coefficient Length)nl A.:al(kip) pi qt) ) Axial (kip) Axial
CCI.1x6 20.4 6.00 0.50 18.00 0.5 0 1 6 0 0 1.21875 65 80 0.80 16 1.00 16 188.8 251.7 i Rupture 283.1 Ruelurr
CCI-1.25x6.5 27.6 8.13 1.06 1861 L 0.615 0 3.25 6.5 0 0 1.21875 65 80 D.80 19 1.00 19 26060.4 347.2 � Compress. 391.4 '' Rupiu�■•
C:)Userx)SUChin Desktop)78875_003_01_AeroColcs)Reinforcement Capacityxlsm 1 of 3 3/27/2015 11:06 AM
Stiffened or Unstiffened, Exterior Flange Plate - Any Bolt Material TIA Rev G
Reactions Bolt Threads:
Site Data Mu 18.15 ft-kips X-Excluded
BU#: 874140 Axial, Pu: 0.622 kips TVn=cp(0.55*Ab*Fu)
Site Name: Progress, OR Shear, Vu: 1.653 kips T=0.75, cp*Vn (kips):
App#: 285805;Revision#3 Elevation: 100 feet 38.88
Pole Manufacturer:I Other If No stiffeners,Criteria I TIA G <-Only Applcable to Unstiffened Cases
Flange Bolt Results _ Rigid
Bolt Data Bolt Tension Capacity,(p*Tn,B1: 54.54 kips w*Tn
Qty: 10 Adjusted cp*Tn (due to Vu=Vu/Qty), B: 54.54 kips ,9Tn[(1-(Vu/9Vn)^2]^0.5
Diameter(in.): 1 Bolt Fu: 120 Max Bolt directly applied Tu: 4.85 Kips
Bolt Material: A325 Bolt Fy: 92 Min. PL"tc"for B cap.w/o Pry: 1.193 in
N/A: <-- Disregard Min PL"treo"for actual T w/Pry: 0.268 in
N/A: <-- Disregard Min PL"t1"for actual T w/o Pry: 0.356 in
Circle(in.): 17.75 _ T allowable w/o Prying: 54.54 kips a'<0 case
Prying Force,q: 0.00 kips
Plate Data Total Bolt Tension=Tu+q: 4.85 kips
Diam: 20.375 in Non-Prying Bolt Stress Ratio,Tu/B: 8.9% Pass
Thick,t: _ 1.5 in
Grade(Fy): 36 ksi Exterior Flange Plate Results Flexural Check Rigid
Strength, Fu: 50 ksi Compression Side Plate Stress: 2.1 ksi TIA G
Single-Rod B-eff:_ 4.55 in Allowable Plate Stress: 32.4 ksi __ 9*Fy
Compression Plate Stress Ratio: 6.6% Pass Comp.Y . Length:
Stiffener Data(Welding at Both Sides) No Prying 10.73
Config: 0 * Tension Side Stress Ratio, (treq/t)^2: 3.2% Pass
Weld Type:
Groove Depth: in ** n/a
Groove Angle: degrees Stiffener Results
Fillet H. Weld: <-- Disregard Horizontal Weld : n/a
Fillet V. Weld: in Vertical Weld: n/a
Width: in Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a
Height: in Plate Tension+Shear,ft/Ft+(fv/Fv)^2:n/a
Thick: in Plate Comp. (AISC Bracket): n/a
Notch: in Pole Results
Grade: ksi Pole Punching Shear Check: n/a
Weld str.: ksi
, - ,-_
Po le Data
Diam: 14.14 in _ Q
Thick: 0.1875 in
Grade: 65 ksi . i,
#of Sides: 12 "0"IF Round a.
Fu 80 ksi r. ' I
Reinf. Fillet Weld 0 "0" if None J
*0=none, 1 =every bolt,2=every 2 bolts,3=2 per bolt
**Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes
CClplate 1.5-Ext Flange G 1.3, Effective March 19,2012 Analysis Date:3/27/2015
■
Anchor Rod Information for TIA/EIA-222-F and TIA-222-G-2
Site Information Base Reactions Design Information
ID: 874140 Moment: 1862 ft-kip TIA Code: G
Name: Progress AerOSOIUt10i)S LLC Axial: 28 kip ASIF: 1.000
App.#: 285805;Revision#3 Optimizing Your Tower Infrastructure Shear: 25 kip Failure: 102%
Base Plate Type: Circular eta Factor: 0.50
Original Anchor Rod Data First Added Anchor Rod Data Second Added Anchor Rod Data Third Added Anchor Rod Data
Quantity: 8 Quantity: 3 Quantity: Quantity:
Diameter: 2.25 in Diameter: 1.75 in Diameter: in Diameter: in
Material: A615 GR 75 Material: A193 B7 Material: Material:
Bolt Circle: 39.3 in Bolt Circle: 45.8 in Bolt Circle: in Bolt Circle: in
Bolt Spacing: in
Bolt Group Area: 31.81 in' Bolt Group Area: 7.22 in2 Bolt Group Area: 0.00 in2 Bolt Group Area: 0.00 in2
Bolt Group MOIx: 6150 in° Bolt Group MOIx: 1628 in° Bolt Group MOIx: 0 in° Bolt Group MOIx: 0 in°
Reactions Seen by Original AR Group Reactions Seen by First Added AR Group Reactions Seen by Second Added AR Group Reactions Seen by Second Added AR Group
Moment: 1472.0 kip-ft Moment: 389.6 kip-ft Moment: 0.0 kip-ft Moment: 0.0 kip-ft
Axial: 27.7 kip Axial: 0.0 kip Axial: 0.0 kip Axial: 0.0 kip
Shear: 25.4 kip Shear: 0.0 kip Shear: 0.0 kip Shear: 0.0 kip
Original AR Capacity Check First Added AR Capacity Check Second Added AR Capacity Check Second Added AR Capacity Check
Combined Load: 237.7 kip Combined Load: 149.3 kip Combined Load: 0.0 kip Combined Load: 0.0 kip
Allowable load: 259.8 kip Allowable load: 189.9 kip Allowable load: 0.0 kip Allowable load: 0.0 kip
AR Capacity: 91.5% Pass AR Capacity: 78.6% Pass AR Capacity: 0.0% AR Capacity: 0.0%
Rev.4.1
Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material
TIA Rev G Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding (1)*(Rod
Diameter)
Site Data Reactions
BU#: 874140 Mu: 1471.9593 ft-kips
Site Name: Progress Axial,Pu: 27.6639 kips
App#: 285805;Revision#3 Shear,Vu: 25.375405 kips
Pole Manufacturer:I Other I Eta Factor, n 0.5 TIA G(Fig.4-4)
Anchor Rod Data If No stiffeners,Criteria: I AISC LRFD <-Only Applcable to Unstiffened Cases
Qty: 8
Diam: 2.25 in
Rod Material: A615-J Anchor Rod Results Rigid
Strength (Fu): 100 ksi Max Rod (Cu+Vu/rj): 234.4 Kips AISC LRFD
Yield (Fy): 75 ksi Allowable Axial, m*Fu*Anet: 260.0 Kips cp*Tn
Bolt Circle: 39.32 in Anchor Rod Stress Ratio: 90.2% Pass
Plate Data
Diam: 45.32 in Base Plate Results Flexural Check Rigid
Thick: 2.25 in Base Plate Stress: 33.2 ksi AISC LRFD
Grade: 60 ksi Allowable Plate Stress: 54.0 ksi cp*Fy
Single-Rod B-eff: 12.74 in Base Plate Stress Ratio: 61.4% Pass Y.L.Length:
23.26
Stiffener Data(Welding at both sides) n/a
Config: 0 * Stiffener Results
Weld Type: Horizontal Weld : n/a
Groove Depth: in ** Vertical Weld: n/a
Groove Angle: degrees Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a
Fillet H.Weld: <-- Disregard Plate Tension+Shear,ft/Ft+(fv/Fv)^2:n/a
Fillet V.Weld: in Plate Comp. (AISC Bracket): n/a
Width: in
Height: in Pole Results
Thick: in Pole Punching Shear Check: n/a
Notch: in
Grade: ksi
Weld str.: ksi
Pole Data
Diam: 31.7 in -
-3 r
Thick: 0.28125 in
Grade: 65 ksi
#of Sides: 12 "0"IF Round
Fu 80 ksi
Reinf.Fillet Weld 0 "0"if None
,i a.
*0=none, 1 =every bolt,2=every 2 bolts,3=2 per bolt
**Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes
CClplate 1.5 -Circular Base G 1.3, Effective March 19, 2012 Analysis Date: 4/7/2015
tCl Foundation Tool Suite-Monopole Pier-Beta Release
CCI Foundation Tool Suite-v1.0 Date: 3/27/2015
BU: 874140
Site Name: _ Progress,OR M CROWN
App Number: 285805;Revisiontl 3 �1,,O.K �'Work Order: 1033165 LAS fJ L f
Monopole Drilled Pier
Input
3"C.C.
Criteria
TIA Revision: G
ACI 318 Revision: 2008
Seismic Category: D
. A
Forces ='I
Compression 28 kips
Shear 25 kips
Moment 1862 k-ft
Swelling Force 0 kips
Foundation Dimensions •1
Pier Diameter: 5 ft \ aS Tie Size
Ext.above grade: 1 ft
Depth below grade: 25 ft I (20)-#10
Material Properties
Number of Rebar: 20
Rebar Size: 10
Tie Size 5
Rebar tensile strength: 60 ksi
Concrete Strength: 4000 psi
Ultimate Concrete Strain 0.003 in/in
- Clear Cover to Ties: 3 in
• •
Soil Profile: Soil ,
Ultimate Ultimate Ultimate
Friction Uplift Skin Comp.Skin Bearing
Thickness From To Unit Weight Cohesion Angle Friction Friction Capacity SPT'N'
Layer (ft) (ft) (ft) (pcf) (psf) (deg) (ksf) (ksf) (ksf) Counts
1 2.5 0 2.5 55 0 0 0 0
2 2.5 2.5 5 60 32 0
3 15 5 20 60 31 0
4 5 20 25 60 34 -3
Analysis Results
Concrete/Steel Check
Soil Lateral Capacity Mu(from soil analysis) 1999.77 k-ft
Depth to Zero Shear: 5.97 ft cPMn 2780.88 k-ft
Max Moment,Mu: 1999.77 k-ft RATING: 71.9%
Soil Safety Factor: 1.83
Safety Factor Req'd: 1.33
RATING: 72.7% rho provided 0.90
rho required 0.50 OK
Soil Axial Capacity
Skin Friction(k): 94.75 kips Rebar Spacing 6.82
. End Bearing(k): 581.70 kips Spacing required 20.32 OK
Comp.Capacity(k),¢Cn: 676.45 kips
- Comp.(k),Cu: 28.00 kips
RATING: 4.1% Dev.Length required 18.78
Dev.Length provided 48.19 OK
Overall Foundation Rating: 72.7%
Page 1 of 1