Loading...
Plans (4) NOTE 1. ALL CONTROL WIRING AND CONDUIT BETWEEN CSS PANELS UTL MCP AND EQUIPMENT ON CSS SKID IS NOT SHOWN FOR CLARITY. 42"lip CLEAR LINE CONTROL FLIGHT INFEED THIS WORK IS TO BE DONE UNDER SEPARATE CONTRACT = TYP CONTROLS EQUIPMENT o PER Estimated BY THE ELECTRICAL CONTRACTOR. .� w TFL5727-PREUM g PROJECT __� _ ; ��\��I �ii�111.1 �� CKDED �)`' I ( el fillil (TMP CRANE RAIL. //////���W Awl I - ____ CCABINETS '�� ^I I ( ( _MI�T SCADA _ J _I � — nal _I RI El 1,1 I ------ IM� I )( el�■ - ------ -- - _--- ups.- _ — _ I COLUMNS rn BUILDING L J NEW CONDUIT 1 - " , TRENCH °° PRU GEN 5 CSS GEN 6 / (FUTURE OPTION) n i_.. , In Er. — 1 // VV aet ` HOLD FOR FURTHER INFORMATION ��' N11 fY• II - W 1-1�h a1 A. /� e. i '_.•!e W •ii.,_, . _,• ��I19 Il=. ', `�� T '� ‘-17-7:11 l♦�I .'4 jS fir CD '4 —\ RECEIVING HOPPER -- - - PRU GEN 6 V� I'I:!jt i V METERING BIN 'te (102) �-r I JP-010 jjEED ,�dr--i _.. __-. -_.___ ,l<.9l�h�l ' IR JP-01 _ ,14� �II� :=St. I, ID6 - ���� r1r. . ea us 1 ii PRIMARY CONVEYOR ,e C.\ mII�I I �_ ;, SANI—TECH • ' �ww� Itia n.n� II��Jik� 1 COMPACTOR 'w',•��1� ., 1 IIl�I 11.11 ve_ •••I: U ' DOOR I' OD ■ �F- ` 11 WEIGH PORTABLE COMPACTOR CONTAINER �� "�'� Milli • ' _)I, I I� SURGE AUGER BE\ji_!'_I1ii�� ' V III) AIRLOCK ,. iINF!a i!r .I VALVES e "In g g4.7.1.$1,144 � �il -.■��I_- �'G UENGH TOWER W QUENCH •II I _ _ _� IT TOWER �. �� •• ...swam — ��Or - wuw; •, INCLINE BELT a. � . w �� _..,, y.. ,...w,.I T.: — , - ICS •/ a' 1���1 � IIE,1#*]_• (I !-!'.110:![7I I - O- NEW CONDUIT TRENCH ^ / / p \A f\,\ O - VACUUM PUMPS a __A _` ^ ELECTRICAL PANEL P4 (`'�//" (E) SECONDARY �RnEQUIRED CLEARANCE, ME litil lad © - - --- ------ © ----------- - -- W A ITY{,,pp�FTIGARD t �; - �w�, (E) UPS �—(E) CONTROL PANEL /y,l,'�t;.'=�lr"II""...........:. I 1: — CONDENSER — W - -. .-- d."�- ' :1 — 'I,; — — — — © — FBI tSFyI nt bYvti k escnbO� e: I � — ___ n iI I[ ( — PE4�tt41YhtO See Lent to 'Prhow 4 3, V \\1\VSS DRIVES PSS DRIVE, DISCONNECT PS UPS (E) SWITCH GEAR (E) DISTRIBUTION (E) NATURAL GAS METER , AND DISCONNECTS AND HEATER CONTROLS PANELS I- -- - - - WITH WIREWAY ABOVE WTTH WIREWAY ABOVE EXHAUST FAN CONTROLS INFEED DISCONNECTS I I W IR DRIVES AND WIREWAY ABOVE _0 O , O - —. - INFEED HYDRAULIC PUMP oF�'ICE COP �,I,� _ COMBINATION STARTER (E) EMERGENCY ---i GENERATOR (!• ') ' ' ` COOL MCP (E) COOLING TOWER ���1��� (E) PRODUCT TANK (E) CHILLER (E) ENVIRONMENTAL CONTROL DEVICE II��II PLAN WWII (El FOAC6 (E) POWER POLE B ADDED DEVICES AND RELOCATED CONTROL PANELS CMT X/XX/2013 A ISSUED FOR CONSTRUCTION CMT 3/06/2013 (E) PL . L SCH IC\ BV '�, I - y,FMR THIS DRAWING IS CONSIDERED CONFIDENTIAL AND PROPRIETARY, a I H DUPLICATION OR TRANSFER, AND COMMUNICATION TO OTHERS IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF AGILYX DRAWN BY: CMT DWG#: AGI06-ELECTRICAL LOCATION PLAN REV: agu I y }-c DATE: DESC B 2/15/13 LOCATION PLAN AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE SCALE: FILE NAME: SHEET: LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE NONE 1 OF 1. 0 Ca C D 9 H C D GEN 6 . 0 HUNZIKER CONSTRUCTION ONE LINES ELECTRICAL DRAWING PACKAGE DRAWI \ G LIST REV DRAWING NUMBER DRAWING TITLE NUMBER DATE AG106 CONSTRUCTION ONE COVER SHEET - SHEET 1 L 4/ 11 /2013 LINE AG106 CONSTRUCTION ONE CONSTRUCTION ONE LINE - SHEET 2 E 4/11 /2013 LINE AG106 CONSTRUCTION ONE CONSTRUCTION ONE LI \E - SHEET 3 D 4/ 11 /2013 LINE AG106 CONSTRUCTION ONE CONSTRUCTION ONE LINE - SHEET 4 G 3/29/2013 LINE AG106 CONSTRUCTION ONE CONSTRUCTION ONE LINE - SHEET 5 H 3/29/2013 LINE AG106 CONSTRUCTION ONE CONSTRUCTION ONE LINE - SHEET 6 E 4/ 11 /2013 LINE AG106 LOCATION PLAN ELECTRICAL LOCATION PLAN A 3/06/2013 H REVISED AS NOTED CMT 3/20/2013 a gi I y}-{ L , REVISED AS NOTED CMT 4/11/2013 K REVISED AS NOTED CMT 4/3/2013 AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE J REVISED AS NOTED CMT 3/29/2013 APPROVA_S DESC RIFTCIN ev b.. R,AH- EET N',C..h Eel SICNA I,HE SEEcIE THIS DRAWING IS CONSIDERED e Era. (F ocess E € !ENTIIETARY,R, AND rcM :hERS IS I yH E�c. !I&C/Flec.j PROHIBITED WITHOUT THE WRITTEN . CONSENT OF AGILYX rrroo CpercJor"s DRAWN BY: CMT DWG#: AGIO6 CONSTRUCTION ONE LINE REV: F1,rchosMc DATE: DESC: L 2/27/13 COVER SHEET Sc I c s SCALE: FILE NAME: SHEET: • C Es:Er-er NONE 1 OF 6 r -1 r 1 r 7 EQUIPMENT ON EAST WALL EQUIPMENT ON CONTROL PLATFORM EQUIPMENT ON THERMA-FLITE SKID C249 LEGEND 1"C, 3-#4 AWG & 1-#8 GND POWER SUPPLIES FOR CAMERAS C251 CAMERAS THREE) © NEMA 1 ENCLOSED FUSED SWITCH - CONTRACTOR SUPPLIED NEW PANEL P15 3/4"C, 6 #14 AWG W/ 1 #14 GND 20/1 -� WIREWAY NEMA 1 WIREWAY SIZE AS REQUIRED - CONTRACTOR SUPPLIED 00 C250 OUTLETS AS READ. _ POWER SUPPLIES C252 O 0 E.) FOR CAMERA LIGHTS I LIGHTS (TYP. FOR THREE) 3/4"C, 2-#12 AWG & 1-#12 GND FOR CAMERA SYSTEM 3/4"C, 3-3/C-#18 SHLD BELDEN 833ME 1 1 SIZE 1 FVNR STARTER SIZE 1 FVNR ENCLOSED COMBINATION STARTER WITH FUSED C235 I COIL NEMA 1 SWITCH, 24VDC COIL, NEMA 1 ENCLOSURE FOR 7.5 HP MOTOR 15kVA XFMR PP-010 I � JP-010 - CONTRACTOR SUPPLIED. 2"C, 6-#2 AWG & 1-250MCM NEUTRAL W/ 1-#2 GND C236 PANEL P5 i 15kVA XFMR. 15 kVA 480-120/240V 1 PH/3W DRY TYPE TRANSFORMER - 2„C, 6 #2 AWG & 1 250MCM NEUTRAL W/ 1 #2 GND I CONTRACTOR SUPPLIED. 500/3 C237 3W I D r. C201 & C202 O 0 I I 1 1/4"C, 3-#2 AWG W/ 1-#8 GND 1 20 CKT PANELBOARD 1PH/3W 100AMP W 60A MCB. FILL WITH 2 - 2 1/2"C, W/4-250MCM & 1 #2 GND IN EACH C238 I PANEL P15 / / 20 AMP ' BR :.ERS - CONTRACTOR SUPPLIED. PANEL SBH 1 1/4"C, 3-#2 AWG W/ 1-#8 GND 30/3 C239 A SIip 1 FVNR COMBO STR SIZE 1 FVNR ENCLOSED COMBINATION STARTER WITH FUSED 1 OVAC COIL NEMA 3R SWITCH, 12OVAC COIL, NEMA 3R ENCLOSURE FOR .5 HP MOTOR O Cl 1 1/4"C, 3-#2 AWG W/ 1-#8 GND - CONTRACTOR SUPPLIED.I 1"C, 3-#10 AWG & 1-#10 GND 7.5 HP 20/3 C240 VFD XF13109 C241 I M0101 �� PART OF C203 3/4"C, 3-#10 AWG W/ 1-#10 GND 3/4°C, 3-#10 AWG W/ 1-#10 GND /1 PYROLIZER SCREW DRIVE A O 0 I . 3/4"C, 3-#12 AWG 7.5 HP C242 C243 MO102 VFD XF13121 PANEL UPS-L 3/4"C, 3410 AWG W/ 1-#10 GND 3/4"C, 3-#10 AWG W/ 1-#10 GND M PYROLIZER SCREW DRIVE B 20/1 --------. PART OF C203 _ 2 HP O O C244 C245 © M0201 13/4"C, 2-#12 AWG & 1-#12 GND - VFD XF13133 COOLING SCREW DRIVE 3/4"C, 3-#12 AWG WI 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND 20/1 1 HP 0 C204 - C246 M0211 I 3/4°C, 2-#12 AWG & 1-#12 GND 1"C, 6-#12 AWG W/ 2-#12 GND I - I EEIII:; PYROLIZER DISCHARGE KNIFE GATE 20/1 1 HP r.0 C205 - i CP-010 M0221 I 20/1 3/4"C, 2 412 AWG & 1 412 GND ASH DISCHARGE KNIFE GATE O O / ` L J 0^O / \ C247 I I•� QUAD OUTLET r EQUIPMENT ON CSS SKID 20/1 3/4"C, 3-#12 AWG & 1-#12 GND I FOR SCADA POWER 1.5 HP �� I C2 1----- P302A O 0- CSS GEN 1 M J COALESCER/SETTLER OIL TRANSFER PUMP 20/1 3/4"C, 3-#12 AWG W/ 1-#12 GND -' C206 1.5 HP O 0 3/4"C, 3 #12 AWG & 1 #12 GND C3 P302B ALL POWER WIRING AND CONDUIT BETWEEN CSS PANELS 20/1 COALESCER/SETTLER OIL TRANSFER PUMP r. 3/4"C, 3 #12 AWG W/ 1 #12 GND AND EQUIPMENT ON CSS SKID TO BE DONE UNDER SEPARATE O O CONTRACT BY THE ELECTRICAL CONTRACTOR. 30/2 1.5 HP O 0 ` C207 C4 �� "' J COLD FINGER BASIN TRANSFER PUMP 1"C, 3-#10 AWG, 2-#12 AWG & 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND �� 20/1 C208 O 0 - - CSS-MCP 3/4"C, 2-#12 AWG & 1-#12 GND 7.5 HP Z ATE FROM PNL SBL CSS-UPS C12 - C13 P101A PANEL UPS-H 3/4"C, 3-#12 AWG W/ 1-#12 GND VFD XF13109 13/4"C, 3-#12 AWG W/ 1-#12 GND I M QUENCH TOWER BASIN TRANSFER PUMP 80/3 7.5 HP C14 VFD V13121 C15 P1016 ' 0 0 Cll - - 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND QUENCH TOWER BASIN TRANSFER PUMP 30/3 I 1 1/4°C, 3-#4 AWG & 1-#8 GND 1 15 HP 3/4'C, 3 #10 AWG & 1 #10 GND C16 VFD XF13133 C17 . .D P303A 3/4"C, 3-#10 AWG W/ 1-#10 GND 3/4"C, 3-#10 AWG W/ 1410 GND l�M/ COALESCER/SETTLER PRIMARY PUMP 15 HP C18 C19 1 P303B I CONTRACTOR SUPPLIED 3/4"C, 3-#10 AWG W/ 1-#10 GND VFDXF13153 3/4t, 3-#10 AWG WI 1-#10 GND M/ COALESCER/SETTLER PRIMARY PUMP PANEL P4 0 0 c.D e 15/1 GTL HEATERS C210 0 0 - I I I I 15/1 3/4"C, 6-#12 AWG & 1-#12 GND r,0-i a CSS HCP C22 (Th XCR13052 0 � H COALESCER TANK OIL HEATER 15/1 3/4"C, 3-#12 AWG W/ 1-#12 GND \.__J 00 0 0 C25 I (----...\ XCR13063 1 H i QUENCH BASIN VESSEL HEATER 100/3 3/4 C, 3-#10 AWG W/ 1-#10 GND 1 C21 - - - C37 i DV13812 0 60/3 0 1 1/2°C, 3-#1/0 AWG & 1-#8 GND 3/4"C, 2-#12 AWG W/ 1-#12 GND 0 PUMP 303A/PIPING/STRAINERS HEAT TRACE 0 C211 C38 i DV13816 C ADDED 3RD GTL HEATER, CHG TO DTS CONTROLLER CMT 3/19/2013 40/3 1"C, 3-#6 AWG & 110 GND 3/4"C, 2-#12 AWG W/ 1 #12 GND 0 PUMP 3038/PIPING/STRAINERS HEAT TRACE B ADDED SHEET 6 CMT 3/08/2013 C212 • 0 C39 i i DV13830 E ADDED COOLING TOWER PUMP STARTER CMT 4/11/2013 20/2 I 1"C, 3-#6 AWG & 1410 GND 3/4"C, 2-#12 AWG W/ 1 #12 GND i i H ) PUMP 302A/PUMP 3028/PIPING HEAT TRACE ,-----.. 1 1 D ADDED SCADA UPS POWER & CAMERA SYSTEM CMT 3/20/2013 O 0 • C40 i i 0 DV13821 HL DESCRIPTION G� E 3/4"C, 2-#12 AWG W/ 1-#12 GND PUMP 101A/PIPING HEAT TRACE CONTRACTOR SUPPLIED rC218 C41 i i H DV13825 THIS PROPRIETARY, • 3/4"C, 2-#12 AWG & 1412 GND 3/4"C, 2-#12 AWG W/ 1-#12 GND I C PUMP 1018/PIPING HEAT TRACE DUPLICATION OR TRANSFER, AND _, I L I J- COMMUNICATION TO OTHERS IS agIlyH \ 4�r -I- �/1 r / PROHIBITED WITHOUT THE WRITTEN \/ L J CONSENT OF AGILYX CONTINUED ON SHEET 3 DRAWN BY: DWG#: REV: a giIyH CMT AGI06-CONSTRUCTION ONE LINE DATE: 2/8/13 oast: POWER ONE LINE E AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE SCALE: •FILE NAME: SHEET: LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE NONE 2 OF 6 CONTINUED ON SHEET 2 / A 7 1 r Y/ -7 V I - I PART OF C206 I INFEED MCP - 3/4"C, 2-#12 AWG & 1-#12 GND PART OF C206 UTILITY PANEL 3/4"C, 2-#12 AWG & 1-#12 GND EQUIPMENT ON CONTROL PLATFORM r EQUIPMENT IN COOLING TOWER AREA L J C203 l COOL MCP 3/4"C, 5 #12 AWG & 1 #12 GND rieri C254 a a. 3/4"C, 6-#12 AWG & 1-#12 GND L -� J I A NEMA 3R C253 (Th 1.5 HP C255 15A FUSE 3/4"C, 3-#12 AWG & 1-#12 GND �� COOLING TOWER FAN C212 \ 3/4"C, 3-#12 AWG & 1-#12 GND T C257 .5 HP 1"C, 3-#6 AWG W/ 1-#10 GND I 3/4"C, 3-#12 AWG & 1-#12 GND COOLING TOWER PUMP C256 SIZE 1 FVNR COMBO STR C258 M .5 HP 3/4"C, 312 AWG & 1 #12 GND 120VAC COIL NEMA 3R 3/4"C, 3-#12 AWG & 1412 GND COOLING TOWER PUMP \\\ "ABU N 6 E) ' ' • •NTROLDEVICE C206 ECD I 1"C, 3-#10 AWG, 2-#12 AWG & 1-#12 GND L J r 15A FUSE EQUIPMENT IN INFEED CONVEYOR AREA F J T C2113 VFD C214 — 5 HP 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND ED PRIMARY CONVEYOR 106 /� 10A FUSE / B\ J > m C215 VFD C216 M 1.5 HP O 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND METERING BIN DRIVE 110A v 10A FUSE F J T C217 VFD C218 — E) 1.5 HP 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND METERING BIN DRIVE 110B E 10A FUSE J -r- C219 VFD C220 M 1 .5 HP 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND TRANSFER CONVEYOR 112 0 10A FUSE (M)F J C221 C222 T _ 1.5 HP 3/4"C, 3-#12 AWG W/ 1-#12 GND VFD 13/4"C, 3-#12 AWG WI 1-#12 GND INCLINE CONVEYOR 114 10A FUSE F -I T C223 VFD C224 — ( 1:4: 1.5 HP 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND SURGE AUGER 118 C225 SIZE 1 FVNR STARTER i C226 7.5 HP 3/4"C, 3 #12 AWG W/ 1 #12 GND 24VDC COIL NEMA 1 3/4"C, 3 #12 AWG W/ 1 #12 GND 1EIII:) FEEDER ASSEMBLY HYDRAULIC PUMP 120 I L J CL j C209 U 3/4"C, 3-#10 AWG W/ 1-#10 GND 15A FUSE r EQUIPMENT ON VACUUM SKID -1 m —IFN 5 HP < C227 C228 �� UVA A - B101A ✓ VFD M VACUUM PUMP A IL 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND \,__,/ • 15A FUSE 0 IF -J 3 5 HP C229 VFD C230 UVA 81016 3/4"C, 3-#12 AWG W/ 1-#12 GND 3/4"C, 3-#12 AWG W/ 1-#12 GND C;) VACUUM PUMP B C211 L J rg j 1°C, 3-#6 AWG W/ 1-#10 GND u 10A FUSE r EQUIPMENT FOR PSS TANK J c .5.5 HP C ADDED SHEET 6 CMT 3/08/2013 M C231 C232 0 UFA-P102 a 3/4"C, 3-#12 AWG W/ 1-#12 GND VFD 3/4"C, 3-#12 AWG W/ 1-#12 GND PSS TANK RECIRCULATING PUMP B CHANGED DESIGNATION CMT 3/06/2013 r w A ISSUED FOR CONSTRUCTION CMT 2/27/2013 Z D ADDED COOLING TOWER POWER CMT 4/11/2013 35 KW R.P. E ESC, =r=-1 L .,_ LI ce C233 PSS HCP C234 0 UFA-JHE106 1°C, 3-#6 AWG W/ 1-#10 GND 1"C, 3-#6 AWG W/ 1-#10 GND PSS OIL HEATER CTH ID RAWIIL AND CONSIDED DUPLICATION OR TRANSFER, AND EQUIPMENT ON EAST WALL COMMUNICATION WITHOUT TO OTHERS THE IS agIIyH L COMMUNICATION TO ORS IS L J CONSENT OF AGILYX DRAWN BY: DWG#: REV: CMT ��I I�V AGI06-CONSTRUCTION ONE LINE fl DATE: 2/8/13 DESC: POWER ONE LINE D AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE SCALE: FILE NAME: SHEET: LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE NONE 3 OF 6 r -I r i EQUIPMENT ON EAST WALL EQUIPMENT ON CONVEYOR SYSTEM C291 I PART OF C291 t UTA-HS106A & B I 3/4"C, 16-#14 AWG (4 SPARE) n - 3/4°C, 2-#14 AWG B - PART OF C291 r 13/4"C, 2 #14 AWG UTA-HS110A - EQUIPMENT ON CONTROL PLATFORM - PART OF C291 I UTA-HS110B / C270 PRIM. CONY. 106 II _ INFEED MCP 3/4"C, 2-#14 AWG 3/4°C, 6-CAT 6E CABLES BELDEN 7852A - PART OF C291 I) UIA-HS112A & B VFD — -4 F- - 3/4"C, 2-#14 AWG - PART OF C291 I IV UTA-11S114A & B METERING BIN 108 I _ PA4RT OF C291.AWG VFD _ _1 I- 3/4°C, 2-#14 AWG UTA-H5118 C292 METERING BIN110 I 3/4°C, 2-#14 AWG + #14 AWG GND VFD — PART OF C293 I UTA LSH 102 - 3/4"C, 2-#14 AWG - PART OF C293 XFER. CONY. 112 I - 3/4"C, 2-#14 AWG I UTA LSL102 EQUIPMENT FOR INFEED CONVEYOR AREA VFD — 1 - C293 - PART OF C293 I 3/4"C, 6-#14 AWG 13/4"C, 2-#14 AWG UTA SS106 INCLINE CONY. 114 I 007 UTA-SSE106 VFD — 1- 1/2" S/T FLEX, 1 PR #18 TW/SH CABLE BELDEN #8760 A SURGE AUGER 118 VFD SIZE 1 FVNR STARTER C271 24VDC COIL NEMA 1 3/4"C, 10-#14 AWG (4 SPARE) C294 3/4"C, 2-#14 AWG + #14 AWG GND PART OF C295 I UTA LSH110 • - A 3/4"C, 2-#14 AWG- OF C295 - 3/4"C, 2-#14 AWG I_ UTA LSL110 - PART OF C295 - I3/4"C, 2-#14 AWG I UTALSH110A - PART OF C295 I I) I UTA-LSH 110B - 3/4"C, 2-#14 AWG C295 I - PART OF C295 ¶308 UTA-SS112 I 3/4"C, 10-#14 AWG 3/4"C, 2-#14 AWG (� 1/2" Sr FLEX, 1 PR #18 TW/SH CABLE BELDEN #8760 ® UIA-SSE112 C296 A3/4"C, 1 PR #18 TW/SH CABLE BELDEN #8760 UTA LT110 A C297 3/4"C, 2-#14 AWG + #14 AWG GND PART OF C298 3/4"C, 2-#14 AWG I UTA LSH112 PART OF Cg72 - PART OF C298 I UTA-SS114 3/4"C, 1-CAT 6E CABLE BELDEN #7852A - 3/4"C, 2-#14 AWG C309 1/2" S/T FLEX, 1 PR #18 TW/SH CABLE BELDEN #8760 ® UIA-SSE114 PART OF C298 UTA LSH118 A 3/4"C, 2-#14 AWG - PART OF C298 - 1 UTA LSL118 3/4"C, 2-#14 AWG I C298 I I I I PART OF C298 t I - UTA-LSH118A 3/4"C, 10-#14 AWG 3/4"C, 2-#14 AWG C299 - 3/4"C, 2-#14 AWG + #14 AWG GND - C300 UTA WT118 e 3/4"C, 1 PR #18 TW/SH CABLE BELDEN #8760 /1 J1 - 1r V r1 , _sill 1 J— /i L r J/1 J 1 r 1 �/ 1 r 1 1/ CONTINUED ON SHEET 5 G ADDED POWER TO UTA-WT118 CMT 3/08/2013 F CLARIFIED INFEED CONTROLS CMT 3/20/2013 E REROUTED C271 TO INFEED MCP CMT 3/15/2013 D FINALIZED INFEED CONTROLS CMT 3/12/2013 RE✓ D CR.!P-lC;\ D' r ,-_ THIS DRAWING IS CONSIDERED e CONFIDENTIAL PRITARY, O H DULICATION OR ANT TRANSFERROPE AND COMMUNICATION TO OTHERS IS PROHIBITED WITHOUT THE WRITTEN O CONSENT OF AGILYX DRAWN BY: DWG#: AGI06-CONSTRUCTION ONE LINE REV: CMT a gi I yH DATE: DESC G 2/11/13 CONTROLS ONE LINE AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE SCALE: FILE NAME: SHEET: LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE NONE 4 OF 6 CONTINUED ON SHEET 4 -r A ` C271 I NOTE 1 3/4"C, 10-#14 AWG (4 SPARE) 1. ALL CONTROL WIRING AND CONDUIT BETWEEN CSS PANELS `, 301 REMOTE I/O t AND EQUIPMENT ON CSS SKID IS NOT SHOWN FOR CLARITY. 3/4"C, 2-#12 AWG + #12 AWG GND THIS WORK IS TO BE DONE UNDER SEPARATE CONTRACT INFEED MCP C302 BY THE ELECTRICAL CONTRACTOR. 3/4"C, 1- CAT 6E CABLE BELDEN #7852A C303 3/4"C, 6-#14 AWG C304 3/4"C, 1 PR #18 TW/SH CABLE BELDEN #8760 C305 3/4"C, 16-#14 AWG C306 3/4"C, 1 PR #18 TW/SH CABLE BELDEN #8760 A t UTA-WT122 PART OF C305 3/4"C, 2-#14 AWG - PART OF C305 - I 3/4"C, 2-#14 AWG UTA-ZSC122 - PART OF C305 It - I 3/4"C, 2-#14 AWG UTA SV123 - I PART OF C305 t UTA-ZSC123 - 3/4"C, 2-#14 AWG - PART OF C305 - 3/4"C, 2-#14 AWG UTA ZS0123 - PART OF C305 - I 3/4"C, 2-#14 AWG - UTA SV124 - PART OF C305 - I 3/4"C, 2-#14 AWG UTA ZSC124 " PART OF C305 It 3/4"C, 2-#14 AWG UTA ZS0124 It UTA-ZT125 - PART OF C303 - 3/4°C, 2-#14 AWG UTA SV125 A -I PART OF C303 It UTA SV130 C273 - 3/4"C, 2-#14 AWG EXHAUST FANS 3/4"C, 2-#14 AWG - I PART OF C303 ® UTA-ZSC130 MCP C274 - 3/4"C, 2-#14 AWG 3/4"C, 16-#14 AWG (8 SPARE) PART OF C303 Z UTA-ZS0130 3/4"C, 2-#14 AWG EQUIPMENT ON CONVEYOR SYSTEM L J ✓ 1 - PART OF 472 C278 PART OF C278 1EQUIPMENT NEAR THERMA-FLITE SKID - 3/4"C, 1-CAT 6E CABLE BELDEN #7852A CSS MCP 1 1/4"C, 9-1PR#18 TW/SH BELDEN #8760 I - 13/4"C, 1PR#18 TW/SH BELDEN #8760 ABA-PT132 - PART OF C278 I ABA-PT133 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 - PART OF C278 I It ABA-PT134 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 - PART OF C278 I It ABA-PCV132 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 - PART OF C278 I Z ABA-PCV133 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 - PART OF C278 I It ABA-PCV134 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 - PART OF C278 I Z ABA-TT135 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 - PART OF C278 I Z ABA-TT136 - 3/4"C, 1PR#18 TW/SH BELDEN #8760 PART OF C278 It 3/4"C, 1PR#18 TW/SH BELDEN #8760 ABA-TT137 J r 1 EQUIPMENT ON THERMA-FLITE SKID A COMPUTER/DISPLAY C307 ® CAMERAS FOR CAMERAS 3/4"C, 3-CAT 6E CABLES BELDEN #7852A (TYPICAL FOR THREE) - PART OF 472 C279 13/4"C, 1-CAT 6E CABLE BELDEN #7852A CP-010 1 1/4"C, 40-TYPE K TC CABLES BELDEN #8390 (8 SPARE) 7P-o11 - EQUIPMENT ON EAST WALL C280 I G ADDED CAMERA SYSTEM CMT 3/20/2013 1"C, 2-10 PR/TW #24 BELDEN #9510 + 4-#14 IAWG F REROUTED C271 TO INFEED MCP CMT 3/15/2013 I C281 I 1 1/4"C, 60-#14 AWG (12 SPARE) E FINALIZED INFEED CONTROLS CMT 3/12/2013 C282 H CHANGED WT120 TO WT122 CMT 3/29/2013 3/4", 2 #14 AWG (E STOP) REV DESC RIPTION B" E.,±,--F r a ✓ EQUIPMENT ON CONTROL PLATFORM J,i J r 1 J `� A EQUIPMENT IN OFFICE THIS DRAWING IS CONSIDERED CONFIDENTIAL AND PROPRIETARY, agilyH ti N EXH FAN EMERGENCY DUPLICATION OR TRANSFER, AND COMMUNICATION TO OTHERS IS \ U / L SHUTDOWN J PROHIBITED WITHOUT THE WRITTEN CONTINUED ON SHEET 6 CONSENT OF AGILYX DRAWN BY: DWG#: AGI06-CONSTRUCTION ONE LINE REV: CMT a gi I Y H DATE: DESC: H 2/11/13 CONTROLS ONE LINE AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE SCALE: FILE NAME: SHEET: LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE NONE 5 OF 6 r CONTINUED ON SHEET 5 EQUIPMENT NEAR COOLING TOWER PART OF C283 / \ 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 I UCA-TT102 �; r 1 -r - PART OF C283 J 1 r ry n.. /I H I j UCA-TT107 -T V J I r — 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 - PART OF C283 - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 UCA TT108 - PART OF C283 I UCA TCV108 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 I - - I PART OF C283 UCA-PT118 - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 - PART OF C283 / - 13/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 UCA-TT203 - PART OF C283 I UCA-PT204 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 I - - I PART OF C283 ® UCA-TT209 1 Ull MCP - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 C283 I - I PART OF C283 I ® UCA-FS r" 1 1/4"C, 8-1 PR#18 TW/SH CABLES BELDEN 0760 3/4"C, 4-#14 AWG (2 SPARE) + 4-#14 AWG I C284 I I COOL MCP C308 SIZE 1 COMBO STR 3/4"C, 1-CAT 6E CABLE BELDEN #7852A I 3/4"C, 8-#14 AWG + GND 120VAC COIL NEMA 3R L J NEAR FIRE WATER FL S , - C308 A 3/4"C, 2-#14 AWG + GND I t CR-4566 1 1 L N r EQUIPMENT ON ECD CONTRACTOR TO PROVIDE AND INSTALL 2PDT COIL RELAY WITH 120 VOLT COIL IN SURFACE MOUNTED ENCLOSURE NEXT TO C285 I I PART OF C285 ECD FIRE WATER FLOW SWITCH AND WIRED IN PARALLEL WITH HORN. 1"C, 22-#16 AWG + 3-1PR#18 TW/SH BELDEN #8760 - 1"C, 15-#16 AWG (4 SPARE) + 3-1PR#18 TW/SH 4 L J r EQUIPMENT NEAR ECD - I PART OF C285 j UEA-EV104 C272 - 3/4"C, 2-#16 AWG + GND 3/4"C, 3-CAT 6E CABLES BELDEN #7852A - PART OF C285 I UEA-ZSO104 - 3/4"C, 2-#16 AWG PART OF C285 3/4"C, 2-#16 AWG UEA ZSC104 L J C274 r EQUIPMENT NEAR AIR COMPRESSOR1 3/4°C, 16-414 AWG (8 SPARE) PART OF C286 I 3 /4"C, 2-#14 AWG I URA PSH110 1 C286 - PART OF C286 3/4"C, 8-#14 AWG (4 SPARE) I 13/4"C, 2-#14 AWG L URA PSL109 J GENERATOR I C275 r i ATS 3/4"C, 8-#14 AWG (4 SPARE) C287 EQUIPMENT FOR VACUUM SYSTEM UVA-EV106 3/4"C, 6-#14 AWG (4 SPARE) PART OF C288 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 UVA PT101A - PART OF C288 - 1 UVA PT1016 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 - PART OF C288 I UVA TT102 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 - UVA - B101A C276 - I PART OF C288 UVA-PT102 VFD I - 13/4"C, 3-CAT 6E CABLES BELDEN #7852A - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 - PART OF C288 - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 UVA PT103 EQUIPMENT FOR VACUUM SYSTEM /� - PART OF C288 Z UVA-FT106 I UVA B101B - / \ - 3/4"C, 2 PR#18 TW/SH CABLE BELDEN #8760 VFD - C288 - I PART OF C288 1-10 UVA-PCV119 1. 1/4"C, 8 PR#18 TW/SH CABLE BELDEN #876p 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 L J r I EQUIPMENT FOR PSS TANK C289 I I 1 UFA-LS226 3/4"C, 6-#14 AWG (2 SPARE) - PART OF C289 I / U \ 3/4"C, 2-#14 AWG PART OF C290 I UFA TE103A 3/4"C, 1 TYPE J T/C CABLE BELDEN #83900 C290 - PART OF C290 I UFA TE110A UFA-P102 3/4"C, 1 BELDEN #83900 & 1 BELDEN #83905 I 3/4"C, 1 TYPE K T/C CABLE BELDEN #83905 D ADDED POWER TO UFA-FT102A CMT 4/3/2013 VFD PART OF C277 UFA-LT101B C ADDED FIRE WATER FLOW SWITCH CMT 3/29/2013 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 B ADDED POWER TO UVA-FT106 CMT 3/20/2013 EQUIPMENT FOR PSS TANK - PART OF C277 I - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 t UFA-FT102A E ADDED COOLING TOWER PUMP CONTROLS CMT 4/11/2013 PSS HCP PART OF C277 I C277 - PART OF C277 UFA TT101A REV DESC RIPTION BY DATE UFA 3C111A 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 - 1"C, 5 PR#18 ?W/SH CABLES BELDEN #8760 - 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 II PART OF C277 - PART OF C277 THIS DRAWING IS CONSIDERED I I z UFA-LT101A CONFIDENTIAL AND PROPRIETARY, agiIyH 1"C, 4 PR#18 TW/SH CABLES BELDEN #8760 3/4"C, 1 PR#18 TW/SH CABLE BELDEN #8760 L DUPLICATION OR TRANSFER, AND J EQUIPMENT ON EAST WALL COMMUNICATION TO OTHERS IS L- J PROHIBITED WITHOUT THE WRITTEN EQUIPMENT ON CONTROL PLATFORM CONSENT OF AGILYX , J DRAWN BY: DWG#: AGI06-CONSTRUCTION ONE LINE REV: CMT agi I y- DATE: DESC: E 3/08/2013 CONTROLS ONE LINE AGILYX PROJECT NUMBER: MASTER CUSTOMER: NONE SCALE: FILE NAME: SHEET: LOCATION: HUNZIKER CUSTOMER PROJECT ID: NONE NONE I 6 OF 6