Loading...
Plans DOLAN TIGARD ALL TECH 1 • Ti . NOISWG 9 MEW Qt M40 A.I,I3 boa a a Too / w r� ► wD • I aaaAIHJat `1.7' sit• TIGARD , OR DOLAN BUILDING OWNER SUMMARY OF WORK 1919 NW 19TH STREET ADDITION OF OFFICE PARTITION WALLS, TWO TOILET ROOMS, AND A BREAKROOM AREA WITH COUNTER AND SINK. RELEASES PORTLAND, OREGON 97209 TELEPHONE: (503) 225-9009 < ,, CONTACT: DAN DOLAN (ddolan©dolanco.com) LEGAL DESCRIPTION _ e_ N O U O .- TAX LOT: 600 & 700 a w N CIDA, INC. ARCHITECT ��� ARCHITECTURAL o z TAX MAP: 02S 01W 02AC ° Z • G1 GENERAL NOTES a a NOTES 15895 SW 72ND AVE, SUITE 200 • • T�.IGFLOOR PLAN/ DETAILS w N PORTLAND, OREGON 97224 ZONING CODE INFORMATION • T1.2 ARCHITECTURAL DETAILS TELEPHONE: 503-226- 1285 ZONING: CBD (CENTRAL BUSINESS DISTRICT) FAX: 503-226- 1670 CONTACT: TARA W. LU N D (taral@cidainc.com NO NEW BUILDING AREA, IMPERVIOUS AREA OR CHANGE OF USE PROPOSED. nn 11 / lJ" I SUMMIT CONSTRUCTION CONTRACTOR `'S BUILDING CODE INFORMATION : , PO BOX 10345 cmoF�c� n—A-- y REVIEWED FOR CODE COII�PLIANCL► , PORTLAND, OREGON 97296 OCCUPANCY CLASSIFICATION: M (MERCANTILE), B (BUSINESS) y +SPRINKLERS: NON-SPRINKLERED " APPtO I TELEPHONE: 503-223-9703 CONSTRUCTION TYPE: III-N OTC:FAX: 503-242-3841 BUILDING AREA (OSSC TABLE 503): Pctmit#: RGlp�o�y-rOc t/L1 Q , EXISTING: 16,995 SF Address: [2) r Q AAPd S ITECT• CONTACT: TIM STROUD (tstroud©sumconst.com) AREA of WORK: 2,743 SF ARCHITECTURE z n Suite#: CCB#: 63249 MEANS OF EGRESS (OSSC CHAPTER 10): By. Data 10( r4 ENGINEERING OCCUPANT LOAD: SEE OCCUPANT LOAD TABLE BELOW P L A N N N G NUMBER OF EXITS REQUIRED: 2 NUMBER OF EXITS PROVIDED: 2 OFFICE COPY INTERIORS LA\ DSCAPE -- - o TRAVEL DISTANCE LIMITATIONS: \ 140.0( 15895 SW 72ND AVE SUITE 200 M OCCUPANCY: 200 FT (71 Fr MAX. PROPOSED) PORTLAND. OREGON 97224 \ S.W. MAIN STREET TEL : 503 . 226 . 1285 %■ 0 \` 0 O O W WxW C 10 D A2I N C .1C O M \\____7— _�■— - - —� — WV� �_ 0 1 -I_ �— lM`-+--�vw -.s' _ -.. a-' r-.�-r r ` OCCUPANCY LO TABLE C = .,.. -Ji e,: s, $ . ' - I . w t� A' cV •I --.11-i uaa-.�®®1u®enoroc .i®s<�ovs. --�_ D, .:. I. s� 7 1 AD T g 1 ( ��= ,1_, i 1 " Ira d z z ' I LOAD FACTOR \ ', I ': r I 1, . -': Pe irtrC RETAIL BUILDING ;y(FUTURE ' — NAME f j pg Wen) A( OCC)I REQUIRED PROVIDED , ; Cl I Grp>_� PHASE 2 II \ \ I1 1 IN! II.ADDITION i SALES 101 M 30 694 24 i 2 M® 1 I %. 5800 SF FIRST FLOOR II II i r \ , i i '105i , PHASE 3 1i I CONFERENCE 102 B 100 204 3 1 2 \; NOM E. MATERIALS: x u WOOD SPECIES . r -�.k•.:. � g;�Et., �N 1. EC ES AND CUT FOR TRANSPARENT FINISH: REFER TO DRAWINGS OR AS•SELECTED BY DIVISION 9: FINISHES K. FLOOR POUSH. REMOVE SOIL VISIBLE ADHESIVE, AND SURFACE BLEMISHES FROM RESILIENT STAIR DIVISION '• ARCHITECT 9.1 NON-STRUCTURAL METAL FRAMING TREADS BEFORE APPLYING LIQUID FLOOR POLISH. • . GENERA. REQUIREMENTS 2. WOOD SPECIES FOR OPAQUE FINISH: ANY CLOSED-GRAIN HARDWOOD r • • A. FRAMING MEMBERS, GENERAL: COMPLY WITH ASTM M C 754 FOR CONDITIONS INDICATED. 1. APPLY THREE COATS. �, 1.1 THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON 3. HARDBOARD: AHA .135.4. B. STEEL SHEET COMPONENTS: COMPLY WITH ASTM C 645 REQUIREMENTS FOR METAL, UNLESS �� t THE DRAWINGS AND GENERAL NOTES AS WELL AS THE PHYSICAL CONDITIONS OF THE BUILDING AND SITE. 4. MEDIUM-DENSITY FIBERBOARD: ANSI .208.2, GRADE MD, MADE WITH BINDER CONTAINING NO 9.8 RESIDENT SHEET FLOORING w. L1�0 `.2 UREA FORMALDEHYDE. OTHERWISE INDICATED. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OF WORK. 5. PARTICLEBOARD: ANSI .208.1, GRADE M-2-EXTERIOR GLUE. C. PROTECTIVE COATING: MANUFACTURER'S STANDARD CORROSION-RESISTANT ZINC COATING, UNLESS A. VINYL SHEET FLOOR COVERING: •6. SOFTWOOD PLYWOOD: DOC PS 1, MEDIUM DENSITY OVERLAY. OTHERWISE INDICATED. 1. UNBACKED VINYL SHEET FLOOR COVERING: ASTM F 1913 0.080 INCH (2.0 MM) THICK. �� 1.2 ALL WORK TO CONFORM TO THE LATEST ADDITION OF THE INTERNATIONAL BUILDING CODE AND ( . ) 7. THERMOSET DECORATIVE PANELS: PARTICLEBOARD OR MEDIUM-DENSITY. FIBERBOARD FINISHED D. WHERE STUDS ARE INSTALLED DIRECTLY AGAINST EXTERIOR MASONRY WALLS OR DISSIMILAR METALS OR APPUCABLE STATE AND FEDERAL SAFETY ORDERS, INCLUDING ADA ACCESSIBILITY- REQUIREMENTS. D. HARDNESS: MANUFACTURER'S STANDARD HARDNESS, MEASURED USING SHORE, TYPE A DUROMETER FORAM, WITH THERMALLY FUSED, MELAMINE-IMPREGNATED DECORATIVE PAPER COMPLYING WITH LMA SAT-1. AT EXTERIOR WALLS, INSTALL ISOLATION STRIP BETWEEN STUDS AND EXTERIOR WALL PER ASTM D 2240. 141 •.% 1.3 THE DESIGN/BUILD SUBCONTRACTORS WILL BE RESPONSIBLE FOR COORDINATION OF ALL WORK WITH THE 8. HIGH-PRESSURE DECORATIVE LAMINATE: NEMA LD 3, GRADES AS INDICATED OR, IF NOT E. INSTALL TRACKS (RUNNERS) AT FLOORS AND OVERHEAD SUPPORTS. EXTEND FRAMING FULL A. WEARING SURFACE: AS SELECTED FORM MANUFACTURER'S FULL RANGE. E�+ OTHER SUBCONTRACTORS INCLUDING THOSE HIRED DIRECTLY BY IONBOND, INC. FOR ALL PHASES OF THE INDICATED, AS REQUIRED BY WOODWORK QUALITY STANDARD. HEIGHT TO STRUCTURAL SUPPORTS OR SUBSTRATES ABOVE SUSPENDED CEIUNGS, EXCEPT WHERE B. SHEET WIDTH: AS STANDARD WITH MANUFACTURER. PROJECT INCLUDING DESIGN, CONSTRUCTION AND CLOSE-OUT. 9. SOLID-SURFACING MATERIAL HOMOGENEOUS SOUD SHEETS OF FILLED PLASTIC RESIN COMPLYING PARTITIONS ARE INDICATED TO TERMINATE AT SUSPENDED CEIUNGS. CONTINUE FRAMING AROUND WITH ISSFA-2. DUCTS PENETRATING PARTI1TONS ABOVE CEIUNG. C. COLORS AND PATTERNS: AS SELECTED BY TENANT FROM FULL RANGE OF INDUSTRY COLORS. F. SUP-TYPE HEAD JOINTS: WHERE FRAMING EXTENDS TO OVERHEAD STRUCTURAL SUPPORTS, D. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY MANUFACTURER TO SUIT FLOOR COVERING 1.4 THE DESIGN/BUILD SUBCONTRACTORS WILL TURN-OVER ALL EQUIPMENT WARRANTY INFORMATION, ALL F. CABINET HARDWARE AND ACCESSORIES: INSTALL TO PRODUCE JOINTS AT TOPS OF FRAMING SYSTEMS THAT PREVENT AXIAL LOADING OF AND SUBSTRATE CONDITIONS INDICATED. FINAL AS-BUILT AUTOCAD INFORMATION, FINAL MUNICIPAL INSPECTION CERTIFICATES, EQUIPMENT 1. BUTT HINGES: 2-3/4-INCH (70-MM), 5-KNUCKLE STEEL HINGES MADE FROM 0.095-INCH- FINISHED ASSEMBLIES. E. INTEGRAL-FLASH-COVE-BASE ACCESSORIES: MANUFACTURER'S OPERATION CHECK-LISTS, QUALITY CONTROL REPORTS, AIR BALANCE REPORTS AND (2.4-MM-) THICK METAL 1. COVE STRIP: 1-INCH (25-MM) RADIUS PROVIDED OR APPROVED BY MANUFACTURER. MAINTENANCE INSTRUCTIONS. 2. FRAMELESS CONCEALED HINGES (EUROPEAN TYPE): BHMA A156.9, B01602. 9.2 GYPSUM WALLBOARD 3. BACK-MOUNTED PULLS: BHMA .156.9 602011. A. GENERAL COMPLYING WITH ASTM C 36/C 36M OR ASTM C 1396/C 1396M AS APPLICABLE TO 2. CAP STRIP: SQUARE METAL, VINYL, OR RUBBER CAP PROVIDED OR APPROVED BY MANUFACTURER. A. THE HEATING VENTILATION AND AIR CONDITIONING SUBCONTRACTOR MUST PROVIDE TYPE WRITTEN 4. WIRE PULLS: BACK MOUNTED, SOLID METAL 4 INCHES (100 MM) LONG, 5/16 INCH (8 MM) IN TYPE OF GYPSUM BOARD INDICATED AND WHICHEVER IS MORE STRINGENT. 3. CORNERS: METAL INSIDE AND OUTSIDE CORNERS AND END STOPS PROVIDED OR APPROVED BY EQUIPMENT MANUFACTURE'S STANDARD START-UP CHECK-LIST FOR EACH PIECE OF EQUIPMENT MANUFACTURER. FURNISHED. IF ANY UNE ITEM ON THE MANUFACTURE'S START-UP CHECK UST HAS NOT BEEN DIAMETER. B. THICKNESS: 5/8 INCH (15.9 MM). LONG EDGES: TAPERED. F. PREPARE SUBSTRATES ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE ADHESION OF FILLED OUT, A REASON MUST BE PROVIDED AS BACK-UP. 5. CATCHES: MAGNETIC CATCHES, BHMA .156.9, 603141, PUSH-IN MAGNETIC CATCHES, C. TRIM: ASTM BHMA A156.9, B03131, ROLLER CATCHES, BHMA A156.9, B03071, BALL FRICTION CATCHES, D. JOINT TREATMENT: COMPLY WITH ASTM C 475/C 475M. G. DO NOT INSTALL FLOOR COVERINGS UNTIL THEY ARE SAME TEMPERATURE AS SPACE WHERE THEY ARE TO 1.5 PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY NEW WORK TO EXISTING CONDITION OR NEW BHMA A156.9, 803013. E. JOINT TAPE: PAPER. BE INSTALLED. CONDITION, WHICHEVER IS MOST APPROPRIATE. 6. DRAWER SLIDES: BHMA A156.9, 805091. F. STEEL DRILL SCREWS: ASTM C 1002, UNLESS OTHERWISE INDICATED. 7. DOOR LOCKS: BHMA A156.11, E07121. G. APPLYING AND FINISHING PANELS, COMPLY WITH ASTM C 840. H. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALUNG FLOOR COVERINGS. 8. DRAWER LOCKS: BHMA A156.11, E07041. H. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW: I. INTEGRAL-FLASH-COVE BASE: COVE FLOOR COVERINGS 6 INCHES (152 MM) OR DIMENSION INDICATED UP A. COMPLY WITH REQUIREMENTS FOR AND LIMITATIONS ON CUTTING AND PATCHING OF CONSTRUCTION } DE ELEMENTS. 9. EXPOSED HARDWARE FINISHES: AS SELECTED BY ARCHITECT OR AS INDICATED ON DRAWING LEVEL 1: CEILING PLENUM AREAS, CONCEALED AREAS, AND WHERE INDICATED. VERTICAL SURFACES. SUPPORT FLOOR COVERINGS AT HORIZONTAL AND VERTICAL JUNCTION BY COVE T B. OPERATIONAL ELEMENTS: DO NOT CUT AND PATCH OPERATING ELEMENTS AND RELATED COMPONENTS LEVEL 2: PANELS THAT ARE SUBSTRATE FOR TILE. STRIP. BUTT AT TOP AGAINST CAP STRIP. INSTALL METAL CORNERS AT INSIDE AND OUTSIDE CORNERS. IN A MANNER THAT RESULTS IN REDUCING THEIR CAPACITY IN PERFORM AS INTENDED OR THAT G. AWI TYPE OF CABINET CONSTRUCTION: AS INDICATED. LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW, UNLESS OTHERWISE INDICATED. J. FLOOR POLISH: REMOVE SOIL, VISIBLE ADHESIVE, AND SURFACE BLEMISHES FROM FLOOR COVERING 3. N RESULTS IN INCREASED MAINTENANCE OR DECREASED OPERATIONAL LIFE OR SAFETY. 1• EDGE TREATMENT: AS INDICATED. PROVIDE TEXTURE TO MATCH EXISTING. BEFORE APPLYING LIQUID FLOOR POLISH. o C. OTHER CONSTRUCTION ELEMENTS: DO NOT CUT AND PATCH OTHER CONSTRUCTION ELEMENTS OR 2. FABRICATE TOPS IN ONE PIECE WITH SHOP-APPLIED BACKSPLASHES OR LOOSE BACKSPLASHES 1. APPLY THREE COAT(S). U) COMPONENTS IN A MANNER THAT COULD CHANGE THEIR LOAD-CARRYING CAPACITY, THAT RESULTS IN FOR FIELD APPLICATION. w c N REDUCING THEIR CAPACITY TO PERFORM AS INTENDED, OR THAT RESULTS IN INCREASED MAINTENANCE H. SHOP FINISHING: TRANSPARENT FINISH 9.5 ACOUSTICAL PANEL CEILINGS a z OR DECREASED OPERATIONAL LIFE OR SAFETY. A. SURFACE-BURNING CHARACTERISTICS: ACOUSTICAL PANELS COMPLYING WITH ASTM E 1264 FOR CLASS v 1. GRADE: PREMIUM. 9.10 CARPETING ($30/YARD ALLOWANCE) Q it D. VISUAL ELEMENTS: DO NOT CUT AND PATCH CONSTRUCTION IN A MANNER THAT RESULTS IN VISUAL A MATERIALS, WHEN TESTED PER ASTM E 84. w EVIDENCE OF CUTTING AND PATCHING. DO NOT CUT AND PATCH EXPOSED CONSTRUCTION IN A 2. AWI FINISH SYSTEM: CONVERSION VARNISH. " A CARPET TILE: PROVIDE PRODUCTS, STYLE, AND COLOR AS SELECTED BY TENANT. o a 3. STAINING: MATCH APPROVED SAMPLE FOR COLOR. B. SEISMIC STANDARD: COMPLY WITH CISCA'S GUIDELINES FOR SEISMIC RESTRAINT OF DIRECT-HUNG w MANNER THAT WOULD, IN ARCHITECT'S OPINION, REDUCE THE BUILDING'S AESTHETIC QUALITIES. SUSPENDED CEIUNG ASSEMBUES--SEISMIC ZONES 3 & 4" AND ASCE 7, "MINIMUM DESIGN LOADS FOR 1• FIBER CONTENT: 100 PERCENT NYLON 6 OR AS SELECTED. N �" REMOVE AND REPLACE CONSTRUCTION THAT HAS BEEN CUT AND PATCHED IN A VISUALLY DIVISION 7: THERMAL AND MOISTURE PROTECTION BUILDINGS AND OTHER STRUCTURES": SECTION 9, "EARTHQUAKE LOADS." 2. PRIMARY BACKING/BACKCOATING: MANUFACTURER'S STANDARD COMPOSITE MATERIALS. UNSATISFACTORY MANNER. 7.1 BUILDING INSULATION C. ACOUSTICAL PANEL STANDARD: COMPLY WITH ASTM E 1264. 3. SECONDARY BACKING: MANUFACTURER'S STANDARD MATERIAL E. PROTECTION: PROTECT IN-PLACE CONSTRUCTION DURING CUTTING AND PATCHING TO PREVENT A. UNFACED, GLASS-FIBER BLANKET INSULATION: ASTM C 665, TYPE I (BLANKETS WITHOUT D. METAL SUSPENSION SYSTEM STANDARD: COMPLY WITH ASTM C 635. 4. SIZE: 24 BY 24 INCHES (610 BY 610 MM). DAMAGE. PROVIDE PROTECTION FROM ADVERSE WEATHER CONDITIONS FOR PORTIONS OF PROJECT MEMBRANE FACING); CONSISTING OF FIBERS; WITH MAXIMUM FLAME-SPREAD AND SMOKE-DEVELOPED E. ATTACHMENT DEVICES: SIZE FOR FIVE TIMES THE DESIGN LOAD INDICATED IN ASTM C 635, TABLE 1, 5. APPLIED SOIL-RESISTANCE TREATMENT: MANUFACTURER'S STANDARD MATERIAL THAT MIGHT BE EXPOSED DURING CUTTING AND PATCHING OPERATIONS. INDEXES OF 25 AND 50, RESPECTIVELY; PASSING ASTM E 136 FOR COMBUSTION "DIRECT HUNG," UNLESS OTHERWISE INDICATED. COMPLY WITH SEISMIC DESIGN REQUIREMENTS. F. ADJACENT OCCUPIED AREAS: AVOID INTERFERENCE WITH USE OF ADJOINING AREAS OR INTERRUPTION CHARACTERISTICS. - F. WIRE HANGERS, BRACES, AND TIES: ZINC-COATED CARBON-STEEL WIRE; ASTM A 641/A 641M, CLASS 1 6. ANTIMICROBIAL TREATMENT: MANUFACTURER'S STANDARD MATERIAL OF FREE PASSAGE TO ADJOINING AREAS. B. FACED, GLASS-FIBER BLANKET INSULATION: ASTM C 665, TYPE III (BLANKETS WITH REFLECTIVE ZINC COATING, SOFT TEMPER. B. TUFTED BROADLOOM CARPET: PROVIDE PRODUCTS, STYLE, AND COLOR AS INDICATED ON DRAWINGS G. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS: WHERE EXISTING MEMBRANE FACING), CLASS A (MEMBRANE-FACED SURFACE WITH A FLAME-SPREAD INDEX OF 25 G. METAL EDGE MOLDINGS AND TRIM: TYPE AND PROFILE INDICATED OR, IF NOT INDICATED, 1. FIBER CONTENT: 100 PERCENT NYLON 6. SERVICES/SYSTEMS ARE REQUIRED TO BE REMOVED, RELOCATED, OR ABANDONED, BYPASS SUCH OR LESS); CATEGORY 1 (MEMBRANE IS A VAPOR BARRIER), FACED WITH FOIL-SCRIM-KRAFT, MANUFACTURER'S STANDARD MOLDINGS FOR EDGES AND PENETRATIONS THAT COMPLY WITH SEISMIC 2. PRIMARY BACKING: MANUFACTURER'S STANDARD MATERIAL. SERVICES/SYSTEMS BEFORE CUTTING TO MINIMIZE INTERRUPTION TO OCCUPIED AREAS. FOIL-SCRIM, OR OIL-SCRIM-POLYETHYLENE VAPOR-RETARDER MEMBRANE ON 1 FACE. WHERE DESIGN REQUIREMENTS; FORMED FROM SHEET METAL OF SAME MATERIAL, FINISH, AND COLOR AS THAT 3. SECONDARY BACKING: MANUFACTURER'S STANDARD MATERIAL H. CUTTING: CUT IN-PLACE CONSTRUCTION BY SAWING, DRILLING, BREAKING, CHIPPING, GRINDING, AND GLASS-FIBER BLANKET INSULATION IS INDICATED BY THE FOLLOWING THICKNESSES, PROVIDE USED FOR EXPOSED FLANGES OF SUSPENSION SYSTEM RUNNERS. SIMILAR OPERATIONS, INCLUDING EXCAVATION, USING METHODS LEAST UKELY TO DAMAGE ELEMENTS BLANKETS IN BATT OR ROLL FORM WITH THERMAL RESISTANCES INDICATED. H. ACOUSTICAL PANELS FOR ACOUSTICAL PANEL CEIUNG: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, 4. BACKCOATING: MANUFACTURER'S STANDARD MATERIAL. RETAINED OR ADJOINING CONSTRUCTION. IF POSSIBLE, REVIEW PROPOSED PROCEDURES WITH C. THERMAL INSULATION: 3-1/2 INCHES (89 MM) THICK WITH A THERMAL RESISTANCE OF 13 PROVIDE PRODUCTS FROM ONE OF THE FOLLOWING: 5. WIDTH: 12 FEET (3.7 M). ORIGINAL INSTALLER; COMPLY WITH ORIGINAL INSTALLER'S WRITTEN RECOMMENDATIONS. DEG F X H X SQ. FT./BTU AT 75 DEC F (2.3 K X SQ. M/W AT 24 DEC C). H.1. ARMSTRONG WORLD INDUSTRIES, INC. OR APPROVED. 6. APPLIED SOIL-RESISTANCE TREATMENT: MANUFACTURER'S STANDARD MATERIAL. 1. PATCHING: PATCH CONSTRUCTION BY FlWNG, REPAIRING, REFINISHING, CLOSING UP, AND SIMILAR " I. TYPE AND FORM: TYPE 111, MINERAL BASE WITH PAINTED FINISH. OPERATIONS FOLLOWING PERFORMANCE OF OTHER WORK. PATCH WITH DURABLE SEAMS THAT ARE AS D. SOUND INSULATION: 3 1/2 SOUND ATTENUATION INSULATION AT ALL INTERIOR WALLS AND AS 7. ANTIMICROBIAL TREATMENT: MANUFACTURER'S STANDARD MATERIAL. NOTED ON PLANS. 1.1. COLOR, EDGE, THICKNESS: MATCH EXISTING. C. PERFORMANCE CHARACTERISTICS: AS FOLLOWS: INVISIBLE AS PRACTICABLE. PROVIDE MATERIALS AND COMPLY WITH INSTALLATION REQUIREMENTS 1.2. MODULAR SIZE: AS INDICATED ON DRAWINGS. SPECIFIED IN OTHER SECTIONS, WHERE APPUCABLE. E. BATT INSULATION INSTALLED IN METAL OR WOOD FRAMED WALLS SHALL BE INSULATED THE FULL °• J. CLEANING: CLEAN PROJECT SITE AND WORK AREAS DAILY, INCLUDING COMMON AREAS. ENFORCE DEPTH OF THE. CAVITY, UP TO 6 INCHES IN DEPTH PER TABLE 13E OF THE IBC. J. COMPLY WITH ASTM C 636 AND SEISMIC DESIGN REQUIREMENTS INDICATED, PER MANUFACTURER'S 1. CRITICAL RADIANT FLUX CLASSIFICATION: NOT LESS THAN 0.45 W/SQ. CM. > 7.2 SEALANTS: SILICON INTERIOR SEALANT. WRITTEN INSTRUCTIONS AND CISCA'S "CEILING SYSTEMS HANDBOOK." 2. DRY BREAKING STRENGTH: NOT LESS THAN 100 LBF (445 N) PER ASTM D 2646. { REQUIREMENTS STRICTLY. DISPOSE OF MATERIALS LAWFULLY. ' A.1. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS, PLUMB AND FREE FROM 3. TUFT BIND: NOT LESS THAN 5 LBF (22 N) PER ASTM D 1335. 61 .., ,,......„..,_„. ,,.. K. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS THAT ENSURE INSTALLED WORK IS WITHOUT DMSbN 8: DOORS AND y CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM. SPLAY HANGERS ONLY WHERE 4. DELAMINATION: NOT LESS THAN 4 LBF/IN. (18 N/MM) PER ASTM D 3936. DAMAGE OR DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. ,. 8.1 HOLLOW METAL DOORS AND FRAMES REQUIRED TO MISS •OBSTRUCTIONS; OFFSET RESULTING HORIZONTAL FORCES BY BRACING, 5. DIMENSIONAL TOLERANCE: WITHIN 1/32 INCH (0.8 MM) OF SPECIFIED SIZE DIMENSIONS, AS ' ._, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. DETERMINED BY PHYSICAL MEASUREMENT. DMSION 2: SELECTIVE DID A. STANDARD HOLLOW METAL FRAMES: COMPLY WITH ANSI/SDI A250.8. A.2. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION WITHIN CEIUNG PLENUM PRODUCES HANGER r , B. INTERIOR FRAMES: FABRICATED FROM COLD-ROLLED STEEL SHEET. SPACINGS THAT INTERFERE WITH LOCATION OF HANGERS, USE TRAPEZES OR EQUIVALENT DEVICES. 6. DIMENSIONAL STABILITY: 0.2 PERCENT OR LESS PER ISO 2551 (AACHEN TEST). 2.1 GENERAL DEMOUSH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW 1. FABRICATE FRAMES WITH MITERED OR COPED CORNERS. . A3. WHEN STEEL FRAMING DOES NOT PERMIT INSTALLATION OF HANGER WIRES AT SPACING REQUIRED, 7. RESISTANCE TO INSECTS: COMPLY WITH AATCC 24. - ,_ CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE THE WORK WITHIN 2. FABRICATE FRAMES AS KNOCKED DOWN UNLESS OTHERWISE INDICATED. INSTALL CARRYING CHANNELS OR. OTHER SUPPLEMENTAL SUPPORT FOR ATTACHMENT OF HANGER WIRES. 8. COLORFASTNESS TO CROCKING: NOT LESS THAN 4, WET AND DRY, PER MTCC 165. - E LIMITATIONS OF GOVERNING REGULATIONS AND AS FOLLOWS: 3. FRAMES FOR WOOD DOORS: 16 GA. S I ILL SHEET. . A.4. DO NOT SUPPORT CEIUNGS DIRECTLY FROM PERMANENT METAL FORMS OR FLOOR DECK; ANCHOR 9. COLORFASTNESS TO LIGHT: NOT LESS THAN 4 AFTER 60 AFU (MTCC FADING UNITS) PER HARDWARE REINFORCEMENT: ANSI/SDI A250.6. INTO CONCRETE SLABS. MTCC 16, OPTION E. _a L, C A. NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO DIMENSIONS REQUIRED. USE D. FABRICATION: A.5. DO NOT ATTACH HANGERS TO STEEL DECK TABS OR TO STEEL ROOF DECK. 10. ANTIMICROBIAL ACTIVITY: NOT LESS THAN 2-MM HALO OF INHIBITION FOR GRAM-POSITIVE CUTTING METHODS LEAST UKELY TO DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING 1. HOLLOW METAL FRAMES: WHERE FRAMES ARE FABRICATED IN SECTIONS, PROVIDE ALIGNMENT B. INSTALL EDGE MOLDINGS AND TRIM OF TYPE INDICATED AT PERIMETER OF ACOUSTICAL CEIUNG AREA AND 15895 SW 72ND AVE SUITE 200 BACTERIA; NOT LESS THAN 1-MM HALO OF INHIBITION FOR GRAM-NEGATIVE BACTERIA; NO FUNGAL PORT:PORTLAND. OREGON 97224 CONSTRUCTION. USE HAND TOOLS OR SMALL POWER TOOLS DESIGNED FOR SAWING OR GRINDING, PLATES OR ANGLES AT EACH JOINT, FABRICATED OF SAME THICKNESS METAL AS FRAMES. WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL PANELS. SCREW ATTACH MOLDINGS TO GROWTH; PER MTCC 174. 5 NOT HAMMERING AND CHOPPING, TO MINIMIZE DISTURBANCE OF ADJACENT SURFACES. TEMPORARILY 2. PROVIDE COUNTERSUNK, FLAT- OR OVAL-HEAD EXPOSED SCREWS AND BOLTS FOR EXPOSED SUBSTRATE AT INTERVALS NOT MORE THAN 16 INCHES (400 MM) O.C. AND NOT MORE THAN 3 INCHES T 5 0 0 3 . z 2 2 a . 2 8 0 COVER OPENINGS TO REMAIN. FASTENERS UNLESS OTHERWISE INDICATED. (75 MM) FROM ENDS, LEVELING WITH CEILING SUSPENSION SYSTEM TO A TOLERANCE OF 1/8 INCH IN 11. ELECTROSTATIC PROPENSITY: LESS THAN 2 KV PER MTCC 134. Fax : 5 0 3 . 2 2 s . 1 a 7 0 B. CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED SURFACES TO AVOID 3. DOOR SILENCERS: EXCEPT ON WEATHER-STRIPPED DOORS, DRILL STOPS TO RECEIVE DOOR 12 FEET (3.2 MM IN 3.6 M). MITER CORNERS ACCURATELY AND CONNECT SECURELY. E. TACKLESS CARPET STRIPPING: WATER-RESISTANT PLYWOOD, IN STRIPS AS REQUIRED TO MATCH CUSHION W W w . C I D A I N c . c o W MARRING EXISTING FINISHED SURFACES. SILENCERS. C. INSTALL SUSPENSION SYSTEM RUNNERS SO THEY ARE SQUARE AND SECURELY INTERLOCKED WITH ONE THICKNESS AND THAT COMPLY WITH CRI 104, SECTION 12.2. C. DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF FLAMMABLE MATERIALS. AT 4. HARDWARE PREPARATION: FACTORY PREPARE HOLLOW METAL WORK TO RECEIVE TEMPLATED ANOTHER. REMOVE AND REPLACE DENTED, BENT, OR KINKED MEMBERS. F. SEAM ADHESIVE HOT-MELT ADHESIVE TAPE OR SIMILAR PRODUCT RECOMMENDED BY CARPET MANUFACTURER CONCEALED SPACES, SUCH AS DUCT AND PIPE INTERIORS, VERIFY CONDITION AND CONTENTS OF MORTISED HARDWARE ACCORDING TO THE DOOR HARDWARE SCHEDULE. FOR SEALING AND TAPING SEAMS AND BUTTING CUT EDGES AT BACKING TO FORM SECURE SEAMS AND TO D. INSTALL ACOUSTICAL PANELS WITH UNDAMAGED EDGES AND FIT ACCURATELY INTO SUSPENSION SYSTEM HIDDEN SPACE BEFORE STARTING FLAME-CUTTING OPERATIONS. MAINTAIN WATCH AND PORTABLE 5. STOPS AND MOLDINGS: PROVIDE STOPS AND MOLDINGS AROUND GLAZED LITES WHERE INDICATED. PREVENT PILE LOSS AT SEAMS. ARE-SUPPRESSION DEVICES DURING FLAME-CUTTING OPERATIONS. FORM CORNERS OF STOPS AND MOLDINGS WITH BUTTED OR MITERED HAIRUNE JOINTS. A AND EDGE MOLDINGS. SCRIBE AND CUT PANELS AT BORDERS AND PENETRATIONS TO PROVIDE G. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX-MODIFIED, HYDRAULIC-CEMENT-BASED FORMULATION D. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS NOT TO E. STEEL FINISHES: A NEAT, PRECISE FIT. PROVIDED OR RECOMMENDED BY CARPET TILE MANUFACTURER. IMPOSE EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS, OR FRAMING. 1. PRIME FINISH: APPLY MANUFACTURER'S STANDARD PRIMER IMMEDIATELY AFTER CLEANING AND 9.6 PAINTING H. ADHESIVES: WATER-RESISTANT, MILDEW-RESISTANT, NONSTAINING, PRESSURE-SENSITIVE TYPE TO SUIT • E. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. PRE-TREATING. C. MATERIAL COMPATIBIUTY: PROVIDE MATERIALS FOR USE WITHIN EACH PAINT SYSTEM THAT ARE PRODUCTS AND SUBFLOOR CONDITIONS INDICATED, THAT COMPLIES WITH FLAMMABILITY REQUIREMENTS FOR 2. FACTORY-APPUED PAINT FINISH: ANSI/SDI A250.3. COLOR AND GLOSS: GRAY (ALTERNATE 17) COMPATIBLE WITH ONE ANOTHER AND SUBSTRATES INDICATED, UNDER CONDITIONS OF SERVICE AND INSTALLED CARPET TILE AND IS RECOMMENDED BY CARPET TILE MANUFACTURER FOR RELEASABLE !'r 2.2 REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR !TENS TO FUNCTIONAL CONDITION ADEQUATE FOR APPLICATION AS DEMONSTRATED BY MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCE. INSTALLATION. INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. 8.2 OVERHEAD STEEL SECTIONAL DOORS- WAYNE DALTON " D. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN 'MPI ARCHITECTURAL I. FOR CARPET TILE COMPLY WITH CRI 104, SECTION 14, "CARPET MODULES," AND WITH CARPET TILE A. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW A. MODEL C24, NON-INSULATEED COMMERCIAL STEEL ON 2" ANGLE MOUNT, OR APPROVED SUBSTITUTION PAINTING SPECIFICATION MANUAL' APPUCABLE TO SUBSTRATES INDICATED. APPLY ALL PAINTS IN STRICT MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. 5 MATERIALS AND EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS B. STANDARD UF? TRACK ACCORDANCE WITH MANUFACTURER'S CAN LABEL REGARDING COVERAGE, THINNING AND DRYING TIMES. NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED. 1. VERIFY MINIMUM 19" HEADROOM AND 4.5" EACH SIDE OF DOOR E. COLORS AND SHEEN: AS SELECTED BY OWNER C. SIZE 1O'-0" X 10'-0" F. SUBMIT DRAW DOWNS FOR COLOR VERIFICATION. 2.3 EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND D. EACH DOOR TO HAVE ON FULL VIEW GLASS SECTION W/ 1/8" CLEAR ANNEALED GLASS IN THE FOURTH G. COMPLY WITH ALL LOCAL AND STATE ORDINANCES REGARDING VOC CONTENT OF PRODUCTS FOR INDOOR SOIUNG DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, STEMS MAY BE REMOVED TO A PANEL UP FROM BOTTOM. - OR OUTDOOR APPLICATIONS. / 12 1... SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION CLEANED AND REINSTALLED IN E. ELECTRIC OPERATORS: UFT MASTER MODEL MT5011, 1/2HP 115V MD1UM DUTY TROLLEY STYLE. H. PAINT ALL EXPOSED FACES' OF ELECTRICAL AND MECHANICAL ITEMS IN PAINTED AREAS INCLUDING PANEL THEIR ORIGINAL LOCATIONS AFTER, SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. ACTIVATED FROM OPEN/CLOSE/STOP PUSH BUTTON STATIONS. ONE SET OF RETRO REFLECTIVE PHOTO BOXES, EXPOSED DUCTWORK, EXPOSED PIPING, ETC. _ W DIVISION EYES WILL BE LOCATED 6" OFF THE FLOOR. I. F. MAXIMUM MOISTURE CONTENT OF SUBSTRATES: WHEN MEASURED WITH AN ELECTRONIC MOISTURE p: M COLD FORMED METAL FRAMING: METER AS FOLLOWS: `p H Cr (V NG INDUSTRY STANDARD ASTM A 446, GRADE A 1. GYPSUM BOARD: 12 PERCENT. . • , 8.3 HARDWARE COMPLY WITH RECOMMENDATIOSN OF AISI NORTH AMERICAN SPECIFlCAITONS FOR THE DESIGN OF A. HARDWARE SCHEDULE SUBMITTALS: PREPARED BY OR UNDER THE SUPERVISION OF INSTALLER, G. VERIFY SUITABILITY OF SUBSTRATES, INCLUDING SURFACE CONDITIONS AND COMPATIBEUTY WITH EXISTING I- < tn N COLD--FORMED STEEL DETAILING FABRICATION AND ASSEMBLY OF DOOR HARDWARE, AS WELL AS PROCEDURES AND FINISHES AND PRIMERS. Z STRUCTURAL C-STUDS: PUNCHED LOAD BEARING STEEL, 1.250 AND 1.375 INCH FLANGE DIAGRAMS. H. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN "MPI ARCHITECTURAL Z B. GENERAL: PROVIDE DOOR HARDWARE FOR EACH DOOR TO COMPLY WITH REQUIREMENTS IN THIS PAINTING SPECIFICATION MANUAL" APPLICABLE TO SUBSTRATES AND PAINT SYSTEMS INDICATED. W WITH 1/4 TO 1/2 INCH STIFFENING UP, SIZE AND GAGE AS INDICATED ON DRAWINGS • SECTION AND DOOR HARDWARE SETS INDICATED IN DOOR AND FRAME SCHEDULE. I. PAINT SCHEDULE: - > CI: El ni m 0 NON-STRUCTURAL C-STUDS: PUNCHED STEEL, 1.250 INCH FLANGE C. ACCESSIBILITY REQUIREMENTS: PROVIDE LEVER TYPE OPERATING DEVICES THAT DO NOT REQUIRE INTERIOR OFFICE AREA: NEW WALLS (MPI INT 9.2A): ONE COAT LATEX OR PVA GYPSUM PRIMER AND WITH 1/4 INCH STIFFENING UP, SIZE AND GAGE AS INDICATED ON DRAWINGS TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST AND THAT OPERATE WITH A FORCE OF NOT TWO COATS EGGSHELL LATEX - COLOR: TBD STRUCTURAL JOISTS: PUNCHED LOAD BEARING STEEL C-SHAPED JOISTS, 1.625 INCH RANGE MORE THAN 5 LBF.(22 N). EXISTING WALLS: TWO COATS EGGSHELL LATEX - COLOR: TBD 3 Q WITH 1/4 TO 1/2 INCH STIFFENING LIP, SIZE AND GAGE AS INDICATED ON DRAWINGS D. LATCHES AND LOCKS FOR MEANS OF EGRESS DOORS: COMPLY WITH NFPA 101. LATCHES SHALL f= < cn ce ACCESSORIES: MANUFACTURER'S STANDARD STEEL TRACK, CUP ANGLES, REINFORCEMENTS, BRIDGING, ETC. NOT REQUIRE MORE THAN 15 LBF (67 N) TO RELEASE THE LATCH. LOCKS SHALL NOT REQUIRE USE 9.7 RESIUENT BASE AND ACCESSORIES POWER DRIVEN ANCHORS: BY HILTT OR ITW RAMSET OF A KEY, TOOL, OR SPECIAL KNOWLEDGE FOR OPERATION. A. RESILIENT BASE STANDARD: ASTM F 1861. ' - Z Q SCREW FASTENERS: SELF TAPPING BY HILT1 OR ELCO INDUSTRIES. E. BUTTS AND HINGES: BHMA A156.1. LI Q (' 1. MATERIAL REQUIREMENT: TYPE TS (RUBBER. VULCANIZED THERMOSET) OR TYPE TP (RUBBER, r1� ::c F. TEMPLATE HINGE DIMENSIONS: BHMA .156.7. THERMOPLASTIC). I - FABRICATION TO COMPLY WITH SPECIFICATIONS FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL G. BORED LOCKS: BHMA A156.2, GRADE 1. MEMEBERS H. MANUAL FLUSH BOLTS: BHMA A156.16, GRADE 1; DESIGNED FOR MORTISING INTO DOOR EDGE. 2. MANUFACTURING METHOD: GROUP I (SOUD, HOMOGENEOUS). Cl BY AMERICAN INRON AND STEEL INSTITUTE I. STANDARD LOCK CYLINDERS: BHMA A156.5, GRADE 1. 3. STYLE: COVE (BASE WITH TOE) OR STRAIGHT (FLAT OR TOELESS). APPLY TOUCH-UP PRIME PAINT FOR GALVANIZED STEEL FRAMING OVER WELD AREAS AFTER COMPLETION OF J. MATERIALS: FABRICATE FROM STAINLESS STEEL UNLESS OTHERWISE INDICATED. 4. MINIMUM THICKNESS: 0.125 INCH (3.2 MM). WELDING K. DOOR CLOSERS FOR MEANS OF EGRESS DOORS: COMPLY WITH NFPA 101. DOOR CLOSERS SHALL 5. HEIGHT: AS INDICATED ON DRAWINGS. INSTALLATION: TO COMPLY WITH ASTM C 754. INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUDS. NOT REQUIRE MORE THAN 30 LBF (133 N) TO SET DOOR IN MOTION AND NOT MORE THAN 15 LBF SECURE TO 6. LENGTHS: COILS IN MANUFACTURER'S STANDARD LENGTH. NOTE: SURFACE MOUNTS MAY NOT (67 N) TO OPEN DOOR TO MINIMUM REQUIRED WIDTH. I g FLOOR AS RECOMMENDED BY MANUFACUTER, NOT MORE THAN 72 INCHES ON CENTER. L. SURFACE CLOSERS: BHMA .156.4, GRADE 1. PROVIDE TYPE OF ARM REQUIRED FOR CLOSER TO BE 7. CORNERS: JOB FORMED OR PREFORMED. PROJECT MORE THAN 4" INTO AISLE SECURE STUDS TO TOP AND BOTTOM TRACKS BY EITHER WELD, RIVET. OR SCREW AT BOTH FLANGES. LOCATED ON NON-PUBLIC SIDE OF DOOR, UNLESS OTHERWISE INDICATED. 8. COLORS AND PATTERNS: AS SELECTED BY ARCHITECT FROM FULL RANGE OF INDUSTRY COLORS. IF MOUNTED 27" TO 80" A.F.F. DMSION B � PLASTICS AND M. METAL PROTECTIVE TRIM UNITS: BHMA A156.6; BEVELED TOP AND 2 SIDES; FABRICATED FROM B. COLORS AND PATTERNS: AS SELECTED BY ARCHITECT FROM FULL RANGE OF INDUSTRY COLORS. 0.050-INCH- (1.3-MM-) THICK STAINLESS STEEL - C. RESIDENT MOLDING ACCESSORIES: 6.1 ROUGH CARPENTRY 1; STOPS AND BUMPERS: BHMA A156.16, GRADE 1. 1. MATERIAL: RUBBER. A. GENERAL: ALL LUMBER AND PLYWOOD TO BE GRADE MARKED IN ACCORDANCE WITH ONE OF THE 2. SILENCERS FOR DOOR FRAMES: BHMA A156.16. GRADE 1; NEOPRENE OR RUBBER; FABRICATED 2. PROFILE AND DIMENSIONS: COVE. • FOLLOWING AGENCIES: WEST COAST LUMBER INSPECTION BUREAU "STANDARD GRADING RULES FOR FOR DRILLED-IN APPLICATION TO FRAME. 3. COLORS AND PATTERNS: AS SELECTED BY TENANT FROM FULL RANGE OF INDUSTRY COLORS. FIRE EXTINGUISHER WEST COAST LUMBER"; WESTERN WOOD PRODUCTS ASSOCIATION "GRADING RULES FOR WESTERN N. DOOR GASKETING: BHMA .156.22. F. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY MANUFACTURER TO SUIT RESIUENT PRODUCTS LUMBER" OR AMERICAN PLYWOOD ASSOCIATION. O. THRESHOLDS: BHMA A156.21. AND SUBSTRATE CONDITIONS INDICATED. oo 1. ACCESSIBILITY REQUIREMENTS: BEVEL RAISED THRESHOLDS WITH A SLOPE OF NOT MORE THAN •a• in B. ALL NAILING TO BE IN ACCORDANCE WITH OSSC 2010 TABLE .2304.9.1, UNLESS NOTED OTHERWISE. 1:2. PROVIDE THRESHOLDS NOT MORE THAN 1/2 INCH (13 MM) HIGH. G. PREPARE SUBSTRATES ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE ADHESION OF C. ALL FRAMING HARDWARE IN CONTACT WITH PRESSURE TREATED LUMBER TO BE HOT DIPPED P. INSTALLATION: RESILIENT PRODUCTS. r- GALVANIZED. 1. STEEL DOORS AND FRAMES: COMPLY WITH DHI A115 SERIES. DRILL AND TAP DOORS AND H.' DO NOT INSTALL RESILIENT PRODUCTS UNTIL THEY ARE SAME TEMPERATURE AS•THE SPACE WHERE THEY GENERAL NOTES SHEET ' D. LUMBER GRADES: FRAMES FOR SURFACE-APPLIED DOOR HARDWARE ACCORDING TO ANSI A250.6. ARE TO BE INSTALLED. 1. ALL SOUD SAWN LUMBER GRADES NOT SPECIFIED TO BE DF12 OR BETTER. 2. WOOD DOORS: COMPLY WITH DHI A115-W SERIES. I. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALUNG RESILIENT PRODUCTS. 2. ALL WOOD IN PERMANENT CONTACT WITH CONCRETE TO BE PRESSURE TREATED. J. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CLEANING AND PROTECTION OF RESIUENT 6.3 INTERIOR CASEWORK 8.4 GLAZING: COMPLY WITH RECOMMENDATIONS SET FORTH IN GANA 'GLAZING MANUAL', UNLESS MORE PRODUCTS. Gal A. GENERAL- REFER TD DRAWINGS FOR LOCATION, SPECIES, FINISH, AND PROFILE CASEWORK ITEMS: STRINGENT REQUIREMENTS ARE INDICATED ON PLANS. "ARCHITECTURAL A. WHERE SAFETY GLAZING IS INDICATED, PERMANENTLY MARK GLAZING WITH CERTIFICATION LABEL OF B. QUALITY STANDARD: UNLESS OTHERWISE INDICATED, COMPLY W111.1 AW1 S ARCHITECTURAL WOODWORK THE SGCC OR ANOTHER CERTIFICAITON AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICATTON, 'I2 FIRE EXTINGUISHER HEIGHT 40,75 0, QUALITY STANDARDS." OR THE MANUFACTURER. LABEL SHALL INDICATE MANUFACTURER'S NAME, TYPE OF GLASS, 1 C. PROVIDE AWI QUALITY CERTIFICATION PROGRAM LABELS AND CERTIFICATES FOR WOODWORK, INCLUDING THICKNESS, AND SAFETY GLAZING STANDARD WITH WHICH GLASS COMPUES. 41 1" = 1'-D" 104413-02 O 20t3 OLY�PC/gd1 ALL RI61{IS ReTiEMIED INSTALLATION. B. FULLY TEMPERED GLASS: ASTM C 1040, KIND FT, TYPE II, CLASS I, FORM 3, QUALITY 06.8.1 D. GRADE "CUSTOM" UNLESS NOTED OTHERWISE. HOLLOW METAL DOORS AND FRAMES ., µ`,4----} MIER& NOTES CONTINUED: J. FOR BROADLOOM CARPET COMPLY WITH CRI 104 AND CARPET AND CARPET CUSHION MANUFACTURERS' ti).12 WRITTEN INSTALLATION INSTRUCTIONS FOR THE FOLLOWING: 1. DIRECT—GLUE—DOWN INSTALLATION: COMPLY WITH CRI 104, SECTION 9, "DIRECT GLUE—DOWN -- INSTALLATION." • ....+;' • 2. DOUBLE—GLUE—DOWN INSTALLATION: COMPLY WITH CRI 104, SECTION 10, "DOUBLE tj PORDJOIQ I GLUE—DOWN INSTALLATION." 3. CARPET WITH ATTACHED—CUSHION INSTALLATION: COMPLY WITH CR1 104, SECTION 11, "ATTACHED—CUSHION INSTALLATIONS." 4. PREAPPUED ADHESIVE INSTALLATION: COMPLY WITH CRI 104, SECTION 11.4, "PRE-APPLIED ADHESIVE SYSTEMS (PEEL AND STICK).". 5. HOOK—AND—LOOP INSTALLATION: COMPLY WITH CRI 104, SECTION 11.5, "HOOK AND LOOP TECHNOLOGY." 6. STRETCH—IN INSTALLATION: COMPLY WITH CRI 104, SECTION 12, "STRETCH—IN INSTALLATION." 7. STAIR INSTALLATION: COMPLY WITH CR1 104, SECTION 13, "CARPET ON STAIRS" FOR GLUE—DOWN INSTALLATION. . DIVISION 1Z FUG 12.1 HORIZONTAL LOUVER BUNDS • A. SLATS: ALUMINUM; ALLOY AND TEMPER RECOMMENDED BY PRODUCER FOR TYPE OF USE AND . FINISH INDICATED; WITH CROWNED PROFILE AND RADIUSED CORNERS. _ 1. WIDTH: 1 INCH (25 MM). B. HEADRAIL FORMED STEEL OR EXTRUDED ALUMINUM; LONG EDGES RETURNED OR ROLLED; FULLY ENCLOSING OPERATING MECHANISMS ON THREE SIDES AND END PLUGS. C. BOTTOM RAIL: FORMED—STEEL OR EXTRUDED—ALUMINUM TUBE, WITH PLASTIC OR METAL CAPPED ENDS. ° o— D. LADDERS: EVENLY SPACED TO PREVENT LONG—TERM SLAT SAG. E, 1. FOR BLINDS WITH NOMINAL SLAT WIDTH 1 INCH (25 MM) OR MORE: BRAIDED STRING. c' N E. UFT CORDS: MANUFACTURER'S STANDARD. o F. TILT CONTROL ENCLOSED WORM—GEAR MECHANISM, SUP CLUTCH OR DETACHABLE WAND PREVENTING OVERROTAIION, AND UNKAGE ROD: . 0.� - G. UFT OPERATION: MANUAL. N N H. MOUNTING: AS INDICATED. I. HOLD—DOWN BRACKETS AND HOOKS OR PINS: MANUFACTURER'S STANDARD. J. COLORS, TEXTURES, PATTERNS, AND GLOSS: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE. K. UNIT SIZES: OBTAIN UNITS FABRICATED IN SIZES TO FILL WINDOW AND OTHER OPENINGS AS FOLLOWS: 1. BUND UNITS INSTALLED BETWEEN (INSIDE) JAMBS: WIDTH EQUAL TO 1/4 INCH (6 MM) PER SIDE . OR 1/2 INCH (13 MM) TOTAL, PLUS OR MINUS 1/8 INCH (3.1 MM), LESS THAN JAMB—TO—JAMB DIMENSION OF OPENING IN WHICH EACH BOND IS INSTALLED. LENGTH EQUAL TO 1/4 INCH (6 - • MM), PLUS OR MINUS 1/8 INCH (3.1 MM), LESS THAN HEAD—TO—SILL DIMENSION OF OPENING IN WHICH EACH BUND IS INSTALLED. 2. BUND UNITS INSTALLED OUTSIDE JAMBS: WIDTH AND LENGTH AS INDICATED, WITH TERMINATIONS BETWEEN BUNDS OF END—TO—END INSTALLATIONS AT CENTERLINES OF MULLION OR OTHER . • DEFINED VERTICAL SEPARATIONS BETWEEN OPENINGS. L PROVIDE INSTALLATION BRACKETS DESIGNED FOR EASY REMOVAL AND REINSTALLATION OF BOND, FOR SUPPORTING HEADRAIL, VALANCE, AND OPERATING HARDWARE, AND FOR HARDWARE POSITION AND BLIND MOUNTING METHOD INDICATED. M. INSTALLATION FASTENERS: NO FEWER THAN TWO FASTENERS PER BRACKET, FABRICATED FROM r } � K. METAL NONCORROSIVE TO BUND HARDWARE AND ADJOINING CONSTRUCTION; TYPE DESIGNED FOR ,, �s SECURING TO SUPPORTING SUBSTRATE; AND SUPPORTING BUNDS AND ACCESSORIES UNDER CONDITIONS OF NORMAL USE. ..K_.<.:.:; .:.:..,Y._ N. INSTALL HORIZONTAL LOUVER BLINDS LEVEL AND PLUMB AND AUGNED WITH ADJACENT UNITS a t ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS, AND LOCATED SO EXTERIOR SLAT EDGES • IN ANY POSITION ARE NOT CLOSER THAN 1 INCH (25 MM) TO INTERIOR FACE OF GLASS. INSTALL INTERMEDIATE SUPPORT AS REQUIRED TO PREVENT DEFLECTION IN HEADRAIL ALLOW CLEARANCES r BETWEEN ADJACENT BLINDS AND FOR OPERATING GLAZED OPENING'S OPERATION HARDWARE IF ANY. DIVISION 15: MECHANICAL 15895 SW 72ND AVE SUITE 200 15.1 ALL MECHANICAL WORK SHALL BE DESIGN BUILT, BY SEPARATE PERMIT. ALL WORK SHALL BE DESIGNED PORTLAND. O R E G O N 97224 IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS INCLUDING ASHRAE STANDARDS. T E L : 5 0 3 . 2 2 8 . 1 2 8 5 A. THE DESIGN—BUILD H V A C CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AND OPERATIVE FAX : 5 0 3 . 2 2 8 . 1 8 7 0 HVAC SYSTEM. WWW . CIDAINC . COIA B. MECHANICAL SUB—CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED APPROVALS AND . PURCHASING PERMITS FOR THE WORK PROVIDED UNDER THIS SECTION. DIVISION 16: aECTRICAVUGHnNG - • 16.1 ALL ELECTRICAL WORK SHALL BE DESIGN BUILT, BY SEPARATE PERMIT. ALL WORK SHALL BE DESIGNED IN ACCORDANCE WITH ALL APPUCABLE CODES AND STANDARDS.- r A. THE DESIGN—BUILD ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AND OPERATIVE ELECTRICAL SYSTEM. B. ELECTRICAL SUB—CONTRACTOR 1S RESPONSIBLE FOR OBTAINING ALL REQUIRED APPROVALS AND PURCHASING PERMITS FOR THE WORK PROVIDED UNDER THIS SECTION. - 16.4 UGHTING: A. PROVIDE BAIIti2Y OPERATED BALLASTS WITHIN BASE BUILDING STANDARD LIGHTING FIXTURES - LIU THROUGHOUT THE SPACE IN ORDER TO PRODUCE EGRESS LIGHTING LEVELS AS REQUIRED BY CURRENT UNIFORM BUILDING CODE AND OREGON STATE REQUIREMENTS. Fin B. PROVIDE HARDWIRED BATTERY BACK—UP OPERATED EXIT SIGN FIXTURES TO CLEARLY INDICATE THE �-- PATH OF EGRESS THROUGHOUT THE SPACE AS REQUIRED BY CURRENT UNIFORM BUILDING CODE (y� AND OREGON STATE REQUIREMENTS. W C. PROVIDE ENERGY COMPLIANCE CODE UGHTING CALCULATIONS WHERE REQUIRED BY CODE. O N MEZZ/ SHED: 60 FOOT CANDLE. - V„ D. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES SHALL BE USTED AND LABELED AS < N DEFINED IN NFPA 70, BY A. QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. L I Z E. FLUORESCENT FIXTURES SHALL COMPLY WITH UL 1598. WHERE LED IS SPECIFIED, TEST W ACCORDING TO NEMA LE 5 AND NEMA LE 5A AS APPLICABLE. MATCH EXISTING UGHT FIXTURES, AS Q LAC INDICATED ON DRAWINGS M 0 F. EMERGENCY FLUORESCENT POWER UNIT: INTERNAL TYPE: SELF—CONTAINED, MODULAR, tL. BATTERY—INVERTER UNIT, FACTORY MOUNTED WITHIN UGHTING FIXTURE BODY AND COMPATIBLE WITH •• BALLAST. COMPLY WITH UL 924. — Q G. EMERGENCY CONNECTION TO MEET ALL APPLICABLE CODES. TEST PUSH BUTTON AND INDICATOR 1— LIGHT SHALL BE VISIBLE AND ACCESSIBLE WITHOUT OPENING FIXTURE OR ENTERING CEIUNG SPACE. Z Q BATTERY SHALL BE SEALED, MAINTENANCE—FREE, NICKEL—CADMIUM TYPE. CHARGER SHALL BE Q FULLY AUTOMATIC, SOLID—STATE, CONSTANT—CURRENT TYPE WITH SEALED POWER TRANSFER RELAY. W INTEGRAL SELF—TEST SHALL BE FACTORY—INSTALLED ELECTRONIC DEVICE AUTOMATICALLY INITIATES H- Immo LL I-- CODE—REQUIRED TEST OF UNIT EMERGENCY OPERATION AT REQUIRED INTERVALS. TEST FAILURE IS N ANNUNCIATED BY AN INTEGRAL AUDIBLE ALARM AND A FLASHING RED LED. H. DESIGN REQUIREMENTS FOR SWITCHES AND DIMMERS: • EACH ROOM TO HAVE A SEPARATE UGHTING CONTROL SWITCH. Z I. EXIT SIGNS: COMPLY WITH UL 924; FOR SIGN COLORS, VISIBILITY, LUMINANCE, AND LETTERING SIZE, COMPLY WITH AUTHORITIES HAVING JURISDICTION. EXIT SIGNS TO MATCH EXISTING AND MEET ALL APPUCABLE CODE REQUIREMENTS. J. INSTALLATION OF UGHTING FIXTURES: SET LEVEL PLUMB, AND SQUARE WITH CEILINGS AND WALLS. .INSTALL LAMPS IN EACH FIXTURE. K. COMPLY WITH NFPA 70 FOR MINIMUM FIXTURE SUPPORTS. 16.4 SUBMITTALS: . A. SUBMIT PRODUCT DATA FOR ELECTRICAL PRODUCTS, EQUIPMENT, AND FIXTURES. B. PROVIDE PLAN SHOWING UGHTING LAYOUT. INDICATE DIMENSIONS, WEIGHTS, METHODS OF FIELD ASSEMBLY, COMPONENTS, FEATURES, AND ACCESSORIES. C. SUBMIT DESIGN CALCULATIONS TO DETERMINE POWER SERVICE REQUIREMENTS, OUTLET, AND LIGHT CIRCUIT LAYOUT, UGHT FIXTURES, AND LIGHTING LEVELS. GENERAL NOTES SHEET- . 2 140175.01 ©2013 ow,P.C./ca 41.Malts MOWED • 16'—6 1/2"/2" / 6'—O" 14'-10 1/2"/2" KEYNOTES _ . _ — FLOOR PLAN AL NOTES ., Y ,`. 0 0 NEW STOREFRONT UNDER SEPARATE PERMIT 1. CONTRACTOR TO REMOVE ALL FLOOR COVERINGS, ACOUSTICAL CEILINGS, TRADE • 0 FIXTURES AND EXTERIOR WALL-MOUNTED SIGNAGE AS NECESSARY. �w L� I 1 - 1-s o 1 © NOT USED 2. COORDINATE WITH TENANT/LANDLORD FOR EXISTING FIXTURES TO BE SALVAGED. W. WD ! ` 3. SERVICE EXISTING HVAC SYSTEM AND ADJUST AS NEEDED TO PROVIDE _�_ ._ a �...._. ...__ to " • - ....•.•-�_,..' I © EXISTING TENANT DEMISING WALL -- 600S125-54 STUDS 16 O.C. TO INDUSTRY STANDARD PERFORMANCE REQUIREMENTS FOR NEW TENANT SPACE - ' T UNDERSIDE OF EXISTING ROOF DECK. INSTALL (1) LAYER 5/8" GYPSUM COORDINATE TEMPERATURE RANGE AND HEATING/COOLING SCHEDULES WITH 3 FORAM, OR ----, :�......•-. ..__......_.. �L _ BOARD ALL--TECH TENANT SIDE (OTHER SIDE ALREADY FINISHED). TAPE, TENANT/LANDLORD. ANY MODIFICATIONS TO THE EXISTING MECHANICAL SYSTEM a�/ • �qt,` '' I PREP AND PAINT ALL-TECH SIDE. ARE TO BE DESIGN/BUILD BY CONTRACTOR UNDER SEPARATE MECHANICAL _._ ..__... u. s , . ' - " a EXISTING EXTERIOR STAIR TO REMAIN. . PERMIT I 101 A ^► 4. MODIFY EXISTING ELECTRICAL SERVICE AS NEEDED TO METER NEW TENANT -i -"° �! �� -+r.� ��++ �' °' SPACE INDEPENDENTLY FROM REMAINDER OF BUILDING. MODIFICATIONS TO ► ►/ ►/ ' 0 EXISTING COLUMN TO REMAIN. '...._.._..__j... `t ELECTRICAL SYSTEM ARE TO BE DESIGN/BUILD BY CONTRACTOR UNDER r SEPARATE ELECTRICAL PERMIT. .._...... ._..1..._._... ... 15'-83, 1/2" " 0 EXISTING CANOPY OVERHEAD 5. ALL NEW HARDWARE TO MEET REQUIREMENTS OF THE ADA. • 10'-0" 12 -0 6. APPLICABLE CODES: ALL WORK SHALL BE IN CONFORMANCE WITH ALL FEDERAL, I ►t - ►•41 B ELECTRICAL POST STATE, AND LOCAL CODES. SPECIFICATIONS AND STANDARDS SHALL MEAN,w. _' �___ ..__.___�_�' �-- ', a m AND ARE INTENDED TO BE, THE LATEST EDITION, AMENDMENT OR REVISION OF■ ____� ...- , ��'' � SUCH REFERENCE STANDARD IN EFFECT AS OF THE DATE OF THE CONTRACT• •EPIC - ,�o 0 EXISTING EXTERIOR WALLS. DOCUMENTS. ;... _ _....... .._- ...:. `; 7. S INDICATED OR IMPLIED AND ` ,t_ ► , 1 105 NOTIFY ARCHITECT OF ANY IDISCREPANCIES.N i_.__..__�. �+- •�- - TENANT ELECTRICAL PANEL - oo g N 8. CONTRACTOR TO VERIFY NEW DOT DISCHARGE NOBSTRUCTNOTIFY PATH TO PUBUC ARCHITECT OF ANY t._._.. .._ .....__ .._ f s S �• I OPEN 1 103 1 CONFERENCE DISCREPANCIES. .T.• �- ' , 1 OFF1 f 9. FIRE EXTINGUISHERS SHALL BE LOCATED AS REQUIRED BY SECTION 906, IFC. 4 : .=.a.. � 106 . ;,, COORDINATE LOCATION WITH FIRE MARSHALL. 10. GLASS USED IN DOORS OR GLAZING LOCATED WITHIN A 24" ARC OF THE • ,s.__..,._._ ........_._._. NEAREST VERTICAL EDGE OF A DOOR OR IN AREAS SUBJECT TO HUMAN a N B IMPACT OR OTHER HAZARDOUS LOCATIONS SHALL BE TEMPERED OR OF AN 4 ci _s,....._....._._. _ a r •+ T 10 -: APPROVED SAFELY GLAZING MATERIAL PER SECTION 2406, IBC. T _ - I & 0 11 VENTILATION NOT INDKATED ON THESE PLANS SHAl1 BE PROVIDED L -- -' WALL TYPES AER SECTION 1203 & 1205 OF THE IBC• u' F ._ A 12. `, - , ►�, ,. b OFFICE A TENANT DEMISING WALL -- REQUIREMENTS 1REMENTS iN SECTION 019, IBCS FOR SMOKE PDENSITY AND FLAME SPREAD- o v _.....4,__.... X07 li- % 1 ` ��•��t"� t� (X t _ . ....___.__ �r O 104-A �����-����-��-1 .! . 600S125-54 STUDS 0 16" O.C. TO UNDERSIDE 13. PROVIDE SIGN STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS D °- O. __.-I: ....:::a .._...._._..: "' _ ALL LOCKING ENTRANCE ..- cv OF EXISTING ROOF DECK WITH SOUND OCCUPIED" PER SECTION 1008.1 8.3, IBC ON N In —: - �;, --:•::-- ATTENUATION INSULATION FULL HEIGHT AND (1) DOORS--COORDINATE WITH DOOR SCHEDULE. _.. _.. _....__� _..-..__ — -- 1 — , LAYER 5/8" GYPSUM BOARD TENANT SIDE. TAPE, 14 EXIT ILLUMINATION SECTION 1006 & SIGNAGE PER SECTION 1011 S PROVIDE EX PER _.-I " "` B MANAG - S OFFICE PREP AND PAINT (ALL TECH TI SIDE ONLY). SEE OF THE IBC. .. ` ►ice. ►-.,,y♦ 8 1� DETAIL 10/T2.1 FOR MORE INFO. 15. CONTRACTOR SHALL COORDINATE ALL NECESSARY TESTING AND REQUIRED ,� _• NV W INSPECTIONS. N 16 LAN ARE TO CENTERLINE OF NEW PARTITION BREAK ROOM --- DIMENSIONS INDICATED ON P ;.... - - IN ,T. _ N (UNDERSIDE OF CEILING1 -- _ �`�' � ����l�l � M. B UNLESS NOTED OTHERWISE. i OFFICE PARITT1O �_._, �,_ --.71---- _.• - , .. NM 1 1o4-B I �' �..-.-- af�.�.!!!!l��. 362S125-33 OR 2 X 4 STUDS ® 16" O.C. TO I ►_— / C UNDERSIDE OF FINISH CEIUNG WITH (1) LAYER t . � ® �, 5/8" GYP. BD. EACH SIDE AND SOUND _..__ ._ _ _. _ u _ I ATTENUATION INSULATION FULL HEIGHT. PROVIDE - . -:ii-. -*S. ,..t.�,,: - ` I ' �` T.R. 17----'; ,. •-�--�-�-•'Y.���------•• :��"�•`-=<.•'.:�''i...=,•;,:.= = �.�. ( '—' ,os _ M WATER RESISTANT GYP BOARD 0 PLUMBING WALLS. rn SEE DETAIL 5/T1.2 FOR MORE INFO. _.-.t,----.4-------,.--.z.."1- .r ..;_:, 61 ;r, I �� I s I INTERIOR PARTION AT GYP, BD. CEILING -- .:. .:a•:. :. ,�f.; r --- I - !' Aik�ii�i�i�i�i�ii�iwti� 16"- _ 362S125 33 OR 2 X 4 STUDS � 1 O C O , =1Z,f;:.a;• ;,�.:I'll:. s `� TTI-f-,01 T.R._...._...._..__ �, r , 7 -11 1/2 UNDERSIDE OF FINISH CEIUNG WITH t LAYER 5/8" ;=i _� '►•, ►•� rn 1 -71' GYP• BD. EACH SIDE AND SOUND ATTENUATION ....---_._- :r:-r�-:--;-.1h.:;‘,;--1.-.-- �- �'� t { I ,i, j ' INSULATION FULL HEIGHT. PROVIDE WATER RESISTANT limillillim_ -tia'- ::.a.:.-4 b :'` .. 1 L ERVER GYP BOARD 0 PLUMBING WALLS. SEE DETAIL 6/T1.2 4 %--..!. .---:-.:::-'.;, ... li3:=--rze.c."5*.fa;-- , : ' ... ns. w�xsx 111 • FOR MORE INFO. ' ; ti. r 1111•'� SCHEDULE QOM FEES N um_ _.... _..._..._� ;::.,: �i:, r _ „2 - — 9- ' 1 _ . - ROOM FLASH HED O 1,g 2E-7) Q 0 NO. ROOM NAME FLOOR BASE N WALL E WALLS WALL W WALL CLNG HEIGHT NOTES a" F-1 CARPET, TBD " 7'-4 3/4" 10_i SALES F-1 B-1 W-1 W-1 W-1 W-1 C-2 11'-6" T_ F-2 SHEET VINYL, TBD . T _ G f, / . . 102 CONFERENCE ROOM F-1 B-1 W-1 W-1 W-1 W-1 _ C-2 9,-O -- F-3 VCT, TBD ` 103 OPEN OFFICE F-1 B-2 W-1 W-1 _ W-1 W-1 C-2 9'-0" r: ` :, F) L I I I 0 I 104 MANAGER'S OFFICE , F-1 B-2 W-1 W-1 W_1 W 1 G-2 9'-Cr e-1 4' sTRAtc�r1 RUBBER BASE, COLOR TBD I t 105 OFFICE F-1 8 1 W-1 W-1 W-1 1Y-1 C-2 9'-O" -- 8-2 6„ COVED RUBBER BASE, COLOR TBD 15895 SW 72ND AVE SUITE 200 I I 106 OFFICE F-1 B-1 W-1 - W-1 W-1 W-1 C-2 9'-Q$ -- PORTLAND. OREGON 97224 107 OFFICE F-1 B-2 W-1 W-1 W-1 W-1 C-2 9'-0' -- T EL : 3 0 3 . 2 2 8 . 1 2 8 5 NAM WAINSCOT 108 BREAK ROOM F-3 B-1 . W-i W-1 W-1 W-1 C-2 9'-Op - W'2 BOARD, Cam' F A X : 5 0 3 . 2 2 6 . , 8 o 0 109 _ TOILET ROOM F-2 8-2 W-1/W-2 W-t W-2 W-1/W-2 W-1/W-2� C-1 B'-O -- " w W w . C I D A ! N C . C 4 M 110 TOILET ROOM F-2 , B-2 W-1/W-2 W-1/W-2 W-1/W-2 W-1/W-2 C-1 , 8''-0 -- COLNIG FINISH NORTH NORTH 111 SERVER F-1 B-1 W-1 W-1 W-1 W-1 C-2 97-6" -- • c-1 PAMRED GYPSUM BOARD REFLECTED CEILING PLAN FLOOR PLAN •112 - VESTIBULE F-1 B-i W-1 W-1 W-1 W-1 C-1 9'-O" -- C-2 SUSPENDED ACOUSTICAL IILE 411 4go 1/8" = 1'-O" 4111 1/8" = 1'-O" r REFLECTED CEiING PLAN LEGEND FLOOR PLAN LEGEND DOOR , 1 c • (N) 1X4 SURFACE MOUNTED FLORESCENT • _ 101-A DOOR NUMBER DATA OUTLET W/ PULL STRING DOOR SCHEDULE• LIGHT FIXTURE CONNECTED TO EMERGENCY (N) GYPSUM BOARD CEILING--PAINT RP SEMI-RECESSED FIRE ' - 'A. FEC TYPE LOCATION OPENING DOOR FRAME ASSEMBLY POWER SUPPLY -- • _ EXTINGUISHER CABINET 5 I CT I (N) 1X4 SURFACE MOUNTED FLORESCENT �« & W OUTLET---CFI AT TOILET ROOM NO. T� R� mat � H R FIRE RATING NOTES NO. Ig EXISTING WALL TO REMAIN UGHT FIXTURE (N) SUSPENDED ACOUSTIC TILE 101-B• B SALES 3'-IT _ 7'--0" 1-3 4" - SC STAIN HMKD PRE�tN 1 --- 101-B (N) 2X4 LAY-1N 18 CELL PARABOLIC Imo■ CEILING---ARMSTRONG CORTEGA SECOND - -•_; - EXISTING WALL TO BE REMOVED 0 FOURPLEX WALL OUTLET 102-A B CONFERENCE ROOM 3'-0" 7'-0" 1-3 4' SC STAIN HMKD PREFIN 1 -- -- 102-A F- LOOK. 2 X 4 OR BL t 1 t.R 102-B B CONFERENCE ROOM 3'--0" 7'-0` 1-3 4" SC STAIN HMKD PREEN 4 ' -- 102-B W FLORESCENT LIGHT FIXTURE CONNECTED TO ��� . a 104-A B MANAGER'S OFFICE 6'--0" 7f 0" 1-3/4" SC STAIN HMKD PREFIN 1 , 104-A EMERGENCY POWER SUPPLY 1., .` .. ,.. NEW WALL--SEE WALL TYPES -- -- �"�� M 104-B B MANAGER'S OFFICE � 3'-0" 7'-0" t-3/4" SC STAIN HMKD PREFIN 1 104-8 (N) 2X4 LAY-IN 18 CELL PARABOLIC '1 es El EN EGRESS PATH 104-C B MANAGERS OFFICE 3'-O" - 7'-0" 1-3/4* SC STAIN HMKD PREFIN 1 -- -- 104-C O Ct Cl FLORESCENT LIGHT FIXTURE 109-A A TOILET` ROOM 3'-O" 7*0u , 1-3J4* ' SC STAIN HMKD , PREF1N 3 -- -- 109-A I L'- 1- N ® EXIT SIGN 110-A A TOILET ROOM 3-0 7 -0 1-3/4 , SC STAIN HMKD . PREFIN 3 1 •110-A Z 112-A A VESTIBULE 3'-0" 7'-0" 1 3,j4" SC STAIN HMKD PREFIN 2 -- . -- , 112-A Qy . 112-B A VESTIBULE 3'-0" , 7'-0" _ 1-3/4" SC STAIN HMKD . PREEN 2 - -- . -- . 112-8 w I Z w < lx - GENERAL DOOR NOTES HARDWARE GROUP 1: i-IADWARE GROUP 2: HARDWARE GROUP 3: a 0 M O • 1 EA. OFFICE LOCK SET 1 EA. EXIT DE1lICE 1 EA. PRIVACY LOCKSET ALL NEW HARDWARE TO MATCH EXISTING HARDWARE STYLE AND FINISH. 1-1/2 PR. BUTTS .7_ I 1 i r Q • NEW DOOR STAIN TO MATCH BUILDING STANDARD 1-1/2 PR BUTTS 1-1/2 PR BUTTS 1 EA. STRIKE 1 EA. FLOOR STOP 1 EA. OCCUPANCY INDICATOR IF- < Cl) fe 1 SET SILENCERS 1 EA. CLOSER 1 EA. WALL STOP 2 4C( ABBREVIATIONS NOTES 1 EA. WALL STOP 1 EA. CLOSER W 0 i0 V REFLECTED. CEIJNNG PLAN AL NOTES AB SOLID CORE WOOD 1, i- p to 1-- HMKD HOLLOW METAL KNOCK-DOWN HARDWARE GROUP 4: THIS DRAWING IS DIAGRAMMATIC AND FOR DESIGN PURPOSES ONLY. PREFIN PREFINISHED 1 EA. PASSAGE LATCH N 1L2wBUTTS CONTRACTOR TO VERIFY EXISTING CONDONS SHOWN OR IMPLIED PRIOR TO CONSTRUCTION. NOTIFY A/E OF ANY DISCREPANCIES. �'" 1" `""` '"1 ' "' AREA OF ALL STOP 0—. ,- • rn WORK ,, 1 EA. CLOSER ELECTRICAL AND UGHTING TO MEET ENERGY CODE AND ADA REQUIREMENTS. ? t. . _1-, . < 1r T ■ MECHANICAL AND ELECTRICAL BY SEPARATE PERMIT. a 1' I y J, y „ SEE FINISH SCHEDULE FOR CEIUNG HEIGHTS AND ADDITIONAL FINISH NOTES. PACIFIC 8,750 SF �" ..•� ' 1 'I 1 + 0 EGRESS PATH LIGHTING TO BE MINIMUM OF 1 FOOT CANDLE. ELECTRICAL SUBCONTRACTOR TO COORDINATE FINAL LOCATION, QUANTITY, O--' �_ ._ 4,,a, ?--.,.•.•. — —:. Nil AND TYPE OF EMERGENCY FIXTURES. ELECTRICAL SUBCONTRACTOR SHALL PROVIDE A/E CALCULATIONS OF AVERAGE AND MINIMUM UGHTING • LEVELS AT EGRESS PATHS. - T TEMPERED t ] I , GLASS CONTRACTOR TO PROVIDE SUBMITTALS TO ARCHITECT PRIOR TO WORK. SUBMITTALS TO INCLUDE HVAC EQUIPMENT-AND LOCATIONS, FINISH ( _��;,�_ • AND TRIM MATERIALS AND ELECTRICAL/UGHTING PRODUCTS INCLUDING LAYOUT AND ILLUMINATION LEVELS, AND FIRE SPRINKLER SUBMITTALS. I I �....� _� ' z COORDINATE SWITCHING WITH OWNER. 0'�' _ . CONTRACTOR TO PROVIDE DESIGN WITH FIXTURE LAMPING TO MEET INTERIOR ILLUMINATION LEVEL COMPLYING WITH INDUSTRY 4 .. _�. _ r 1 1 FLOOR PLAN/ DETAILS ELECTRICAL STANDARDS IN ALL ROOMS. PROVIDE ILLUMINATION LEVELS TO ARCHITECT SHOWING COMPLIANCE. 1 ( I I I I LIGHTING AND HVAC DRAWINGS TO BE COORDINATED BY CONTRACTOR PRIOR TO INSTALLATION. ° ``' ',moor — — — • • o 1 1 i 1 1 1 1 A (B)FLUSH REL17E • T1.1 EXTSTTNG LIGHT FIXTURES TO BE REMOVED. CONTRACTOR TO COORDINATE WITH LANDLORD REGARDING SALVAGE OF EXISTING LIGHT FIXTURES. NORTH . 9 KEY PLAN DOOR TYPES 140175.01 SI 11.1 N.T.S. 1531,1 1/4" = i'-o" ©}203 ODA PC./caw► P mans mum _ T _ • �yy� ,,,,,,,,:,,v„,,,,,, ,„• ______ ________ __ 12 GA. HANGER WIRES 0 4'-0" �L!IlIQ �� n._._.._......._.._. ... .. 9 O.C. (TYP.) , 416" . COMPRESSION BRACE 3/4` �e • .assi/w..,.....::...,.. ..tp..!H'n..4: ii:M+Y .„, i..,?..... t 7:n'v'd:::f 3d sa.:.i_.... \ 7C STANDARD PIPE �-�" "`� . j� 2" MIN. `►� • ,. -+ 12 GA. SPLAYED BRACE WIRES � n x _._....--_-----...... T.R. ��. (TYP.) ' �_. ._',-..� a SUSPENDED CEILING 1 II 109 �`� F( �s Al = PROVIDE METAL STUD BRACE AT - I " ' / '� CROSS TEE w ' 6'-0" O.C. TO STRUCTURE ABOVE -: 77041 i f ! AND TO TOP PLATE OF PARTITION • / z TRIM P2A)fVEL AS REQUIRED. - GYP. BD. ( ��' w I 1 ' A ' n °�`:,, '� / a CONT. TOP TRACK- ATTACH TO STEELn.nCa'.Y-r •:R...r.:a:e'''-'a`Y':4i:a:: rel?s:: 3 ,,.. �` 1" E S" "<. _ .. ..;...-,,.x.�.:�, :;;•,,:,y,.�:..,,,,.'T; i- CEILING GRID W/ TYPE " STUD----DOUBLE L--I MAIN TEE SCREWS AT 2'-0" O.C. STUD AT ALL �" - 3 JAMBS .__ � � #� / 0 TIMELY KNOCK . ' �" ,f x") TIMELY METAL STUD PARTITION PER PLAN DOWN FRAME • T.R. ' CO • - : ..• . ., ,. . - BASE w ,. % N BOTTOM TRACK TO FLOOR WITH ANCHORS AT Li,-O" O.C. (MAX) AND. CY', AT CORNERS D ENDS d Z ANMILMINIKII N. DOOR-SEE DOOR i a a CNEDULE r N TYPICAL HOLLOW __ ... . ...-. _._ – 0 METAL INTERIOR DOOR k4 ENLAR TOI T PLAN SEISMC BRACING FOR SUSPENDED CEO TYPICAL INTERIOR PARTITI ON . 3" = 1'-0" 3/8" = 1'-0" 0 3" = 1'-0" 095123-02 3/4" = 1'-0" 092900-04 I . s B ELEVATION 1 0 ELEVATION 2 ELEVATION 1 ELEVATION 2 3625125 30 STEEL JOISTS AT 16" O HEADER SECTION '- o o j 0.C. : • • - - . - - SPAN HEADER SECTION ,; ;• . ' . - 3•-6' 400 S137-33 ' • 11111 PI% 6'-9' 600 S135-33 9'-12' 600 S162-43 c a t }• i ._-- _ - KEYNOTES 4. c © A � ; 110 SMS EA. E AT HEADER 1ç: = DETAIL 9/T1.2 SUSPENDED CEIUNG bY O ���� M �i 3- " © ���.4. IGHT GAGE STUD WALL STUD PER PLAN ® GRAB BARS -- SEE DETAILS 9/T1.2 E% -:,,,,::_,P1‘, „ c� i►. 1/2 SOUND ATTENUATION BATT 20 GA MIN. AND 11/T1.2 Z �� WHERE SCHEDULED a " = (2} ROWS OF X10 HEADER BELOW COUNTER LAVATORY -- SEE DETAILS w TOILET i� 0 �` 5/8" GYP. BD. ELEVATION 3 ELEVATION 4 12" 9/f 1.2 AND 12 1.2 ~ o ROOM/ ELEVATION 3 ELEVATION 4 _ MS AT 12 O.C. �. r. ` ,; F- - Q 20 GA. TRACK TO MATCH WALL • MIRROR 24" X 36" HIGH MOUNTED AT 0 " " 15895 SW 72ND AVE SUITE 200 / gal , 3'-4" A.F.F. PORTLAND, OREGON 87224• SIVESTIBULE METAL STUD PARTITION PER PLAN _ FRAMING W/ X10 SMS AT Q �� - •. ! TEL : 503 . 228 . f 288% w �i : . . _ 2" O.C. EACH FLANGE // ligiki \ \ ��', j . __ - © WALL MOUNTED PAPER TOWEL FAX : s a s . 2 2 s . s 7 a DISPENSER WWW . CIDAINC . 00M �i BASE PER SCHEDULE I `'� �- . i! BOTTOM TRACK TO FLOOR WITH � !�1 �,i�� _ �' © \ © ��� ��; , 1'1 { O WALL MOUNTED LIQUID SOAP DISPENSER c _ '� 40011 00-33 EA. SIDE--COPE � m� EADER SECTION PER SCHEDULE '� . POWDER DRIVEN ANCHORS AT 4'-0" L!c-- ' J J 0 WALL MOUNTED TOILET PAPER w ►�i (� O GES AS REQ'D AT HEADER w , . (MAX) O.C. AND AT CORNERS AND \ O • jI`� ENDS , ' " --SEE 9/Ti.2 --,— 10 SMS AT 12 O.C. EA. SIDE. "•�� © Q� 9 10 SMS AT 8* Q.C. t A. SIDE ■ :s. N.T.S. 20 GA. TRACK BASE PER FINISH SCHEDULE r ROOM 109 ROOM 110 © 0 N.T.S. . PAINTED GYP BOARD PER FINISH 4) SCHEDULE X 48" PAM WAINSCOT PER FINISH SCHEDULE FRAM FOR NON—BEARING 0 6 TYP. IsiTERIOR PARTITION @ GYP. BD. CEIUNG 8 TOILET ROOM ELEVATIONS PARTITION WALLS 3/4" = 1'-0" 092900-07 1/4" = 1'-0" 1 1/2" = 1'-0" 08001-03 W o It M N MIRROR t-- < h. .. STEEL STUD WALL--PER PLAN La Z (fy � Et F.) O SEALANT a a 3/4"x6" PLYWOOD BACKSPLASH 3 CC a --ATTACHED TO EACH STUD W/ (2) #6x2" i- (/) Lt NOTE: WHEN SELF RIMMING BUGLE HEAD SCREWS (COUNTERSINK HEADS) Z 4:11 4gC I SINK IS USED, 2'-10" SET BACKSPLASH IN CAULK Z MEASUREMENT IS TO TOP OF FACE W/ PLASTIC LAMINATE. Z 0 0 SINK RIM RATHER THAN COUNTER. ,NOTE: ALL ACCESSIBLE TOILET • 3/4" PLYWOOD TOP AND EDGE ATTACHED ~ p 0 !—12" MAX. 42" MIN. • " " �., STALLS AND ACCESSORIES _ ATT TOP W tNi " 36 MIN. / • �� SHALL COMPLY WITH UBC SEC. �a ® 6 Q.G/(COUNTERSINK HEADS)CREWS �•- t39 —41 " !- 1109.10.5 AND ADAAG 30. �! FAGS W/ PLASTIC LAMINATE 24 MIN.1,1 2 `� , ♦ _ z '� MIN'S �� ( I SEE PLAN FOR FIXTURE I i {I1 NOTE: WHEN SELF RIMMING SINK IS Q ♦ \ PLACEMENT. PARTITIONS ■ " \ / ONS AS USED, 2 -10 MEASUREMENT IS TO TOP 1 "' �Iw_' INDICATED ON PLAN. OF SINK RIM RATHER THAN COUNTER. e� .=;:- i a' $T 0.--� ♦ • 4----1 MIRROR - —� I I 0 ----1 %% SEE FINISH 4 (2) 2x4 AT FACE OF COUNTER I 1 (Nil/ SCHEDULE °C `'� ` ,-f . . ♦ _ 1 1/4" TO 1 1/2" ._1 0 / m to v- ♦ \ 1 1/2" / - ♦=i a� -1 0 < < I Q 2x4--ATTACH TO WALL W 2) 8g SEE PLAN FOR o M �, 1 / FIXTURE z 7 K' ' ' o `� WOOD SCREWS FACH STE1D PLACEMENT. I n ♦ ,` ♦ ♦ \ ! ! CERAMIC TILE BASE PARTITIONS AS 7"--9'• r♦ ♦ i 1 " NO SCALE INDICATED ON l' 1 1 --3 MIN. PLAN. 6"-18" 1 1 VANITY SINK PAPER TOWEL �I ARCHITECTURAL DETAILS DISPENSER/ WASTE T11.2 s FIXTURE MOUNTING HEIGHTS RECEPTACLE GRAB BAR 12 TOILET ROOM COUNTER 3/8" = 1'-0" flii) 140175.01 NO SCALE 10800-01 1" = 1'-0" • ©2013 00A,P.C./OW ALL RICF05 RESERVID ''..`,'',:-:'-‘i4`',/ %^ `-' • 1 �F i