Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
1 a A 4 — - - Code Analysis General Notes — - _ BASED ON THE 2009 INTERNATIONAL BUILDING CODE (IBC) WITH A. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS NOTIFY / 2010 OREGON STRUCTURAL AND SPECIALTY CODE AMENDMENTS ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OF WORK. '' 4-00 / B. ALL HARDWARE IN ACCORDANCE WITH ANSI 117.1. MILDREN DESIGN GROUP, P.C. ti\ / OCCUPANCY AND CONSTRUCTION PER OSSC 304.1, 311.2 AND 602.3 C. PROVIDE (1) APPROVED FIRE EXTINGUISHER WITH RATING OF NOT LESS ARCHITECTURE • SPACE PLANNING \---�i `-__ OCCUPANCY: B THAN 2-A: 108 FOR EACH 3,000 SQ.FT. OF FLOOR AREA TRAVEL FROM 7650 S.W. Beveland, Suite 120 ANY PORTION OF BUILDING NOT TO EXCEED 75'. COORDINATE Tigard, Oregon 97223-8692 CONSTRUCTION TYPE: II-B LOCATION OF FIRE EXTINGUISHERS WITH FIRE MARSHAL. (503) 244-0552 D. 10090 SPRINKLERING TO BE MAINTAINED THROUGHOUT IN ACCORDANCE FIRE-RESISTANCE RATING WITH N.F.P.A. PAMPHLET #13 (BY SEPARATE PERMIT). I REQUIREMENTS PER OSSC TABLE 601 E. LEVEL 4 FINISHED WALLS, PAINT SYSTEM (1) COAT PRIMER, (2) COATS STRUCTURAL FRAME: 0 HRS. ---- ^ /-?-------so EXTERIOR BEARING WALLS: 0 HRS. ACRYLIC LATEX AT OFFICE SIDE OF WALLS AT NEW WALLS AND WALLS / 1 ) -•- EXTERIOR NON-BEARING WALLS: 0 HRS. DAMAGED OR MODIFIED DURING CONSTRUCTION. INTERIOR NON-BEARING WALLS: 0 HRS. F. FURNISH THREE SILENCERS FOR SINGLE ACTING SINGLE DOORS. DO — _ _ _ - '� FLOOR CONSTRUCTION: 0 HRS. NOT FURNISH SILENCERS FOR DOORS WITH WEATHERSTRIPPING OR — i _ _ _ �� ROOF CONSTRUCTION: 0 HRS. GASKETING. G. VERIFY POWER AND DATA REQUIREMENTS WITH OWNER AND TENANT. FIRE PROTECTION: BUILDING IS EQUIPPED WITH AN H. CLEAN BLINDS, REPAIR OR REPLACE DAMAGED BLINDS AUTOMATIC FIRE PROTECTION SYSTEM I. REPAIR DAMAGED OR STAINED SUSPENDED CEILING TILES. I 1 THROUGHOUT IN ACCORDANCE WITH OSSC J. RELOCATE EXISTING LIGHT FIXTURES FOR NEW WALLS. u �, 903.3.1.1 K. BALANCE HVAC FOR NEW WALLS/ROOMS. FLAME SPREAD INDEX: NOT MORE THAN 25 SMOKE DEVELOPED INDEX: NOT MORE THAN 450 CITY OFTIGAl D ,- B OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT �aevtl�o�anFVaco>warcaa�rx, t s 4 �� \ I EXCEED 100'-0" PER OSSC SECTION 1014.3 ATP ' '� \ \ \ EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 300'-O" wi, PER OSSC SECTION 1016.1 Pandt* icRj4-00/J5-g DANiE 45 r r , 1 Address: .�` �r`∎:��_..� � • • OREGON ; \ \ M. ■ Sint!#t `. ��� (- EGRESS ILLUMINATION: PER OSSC SECTION 1006 B -- ¢ --� ■: _ MEANS OF EGRESS, INCLUDING EXIT DISCHARGE, SHALL BE n _ rrr f OF CW i iiiIiiiiiiiiiliiiiiitiiiiiiiiiiiiiiiiiiiiiiii�:�1'�:� i - ILLUMINATED AT ALL TIMES THE BUILDING IS OCCUPIED. PROVIDE MINIMUM 1 FC ILLUMINATION AT THE FLOOR LEVEL. _ I EMERGENCY LIGHTING: IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY OFFICE COPY Client -- - -- ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE I PORTION OF THE EXTERIOR EXIT DISCHARGE IMMEDIATELY S`�zq l 1 pacific NW ADJACENT TO EXIT DISCHARGE DOORWAYS IN BUILDINGS CICA REQUIRED TO HAVE TWO OR MORE EXITS WITH THE EXIT ILLUMINATION SUPPLEMENTED WITH AN EMERGENCY POWER Properties SUPPLY CAPABLE OF PROVIDING POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES PER OSSC SECTION 1006.3. 1 I 1 N a Deferred Submittals I C 6600 S.W. 105th Avenue EXISTING BUILDING ELECTRICAL Beaverton, Oregon 97005 SPRINKLER j - Project Q I Room Symbol Legend TI for L I ROOM AREA/LOAD f ROOM NAME Superior FACTOR OFF! Ems` ROOM NUMBER CO -- FINISH Group -- \B29 _ —Ro0M PER IB OCCUPANCY GROUP _ _ _ PER IBC TABLE XXX/100:2�_NUMBER OF _ I - / 1004.1.2/NUMBER B:2 E ITS OCCUPANTS i 13535 SW 72nd-Suite 135 ` _ _ _ _ NUMBER OF ar — 1___ _ .f___ ______ ' -- --1. _ EXITS PROVIDED Tigard,d, Or eg on 1 0 ELEC LEcil Sheet Title Allk AREA OF WORK Mr Cover Sheet i _ 1 I I I / 0 ^^ \ — I M _w l .....• I ___.1 pr u .... r 1 dim • --, • t __ - -- �DFEC `` i Revisions: uui nui uuunum A'I 1 , I I u dr.-:!nu°O1 I c = /c, mi m ii, 0 / .... Pr I I A E 0111 .L.,..._ r Illp : • A Ard. 1 iremi .= ii - --- ---1 -c 1 .....=rie 0,-.w. i:;-= ip ! I IFI: L 7.... 1 _.....f. _ _ _ , I fi- if 1 . 1 \* - wI hAt III 1 Illi . I mil 1 r _= I MILDREN DESIGN GROUP, P.C., 2014, ALL LAW \ / ( I - , - RIGHTS RESERVE i I� D© Ni �� - _ _ _ _ .� 'i""' • „" THESE DRAWINGS ARE THE PROPERTY OF • —� II . MILDREN DESIGN GROUP, P.C., AND ARE �• • . NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION rawn by OF: MILDREN DESIGN GROUP, P.C. t 0 Date 17 July Checked 2014 by: o SW Cherry St At BK DAV First Floor Key Plan Job Number: 114131 yr Site Plan Sheet Mr 0 5 10 20 40 0 5 10 20 40 Permit Submittal - July 2014 AO Symbols Keynotes Q- . 6 O 9 9 © 1. EXISTING ACCESSIBLE COFFEE BAR . ...■•r•.,..., DOOR SYMBOL 2. ALIGN NEW WALL WITH EXISTING 3. (2) DUPLEX OUTLETS: 15A DEDICATED CIRCUITS MILDREN DESIGN GROUP, P.C. DFEC FIRE EXTINGUISHER IN SEMI-RECESSED CABINET ARCHITECTURE • SPACE PLANNING 7650 S.W. Beveland, Suite 120 Finish Schedule Tigard, Oregon 97223-8692 (503) 244-0552 �"- -- Wall Legend ROOM NAME I / Floor Finish - A4BB9 � 0 \\ I I EXISTING WALL TO REMAIN / \ X. EXISTING TO REMAIN Z ...m..•.,,., 3%3" METAL STUDS WITH %" GYPSUM BOARD TO BOTTOM OF CEILING Base III -------- I//I/I s�_�rr�rrrasrrrrr�sal// '���-----.. ��rrrrrrrrr�►rrr�,- / 4. 4" RUBBER BASE p T �' �' j/ X. EXISTING TO REMAIN B li r== ,__= _.r_m Door Types Wall Finish / CE RE NCE OFFICE _ PAINT UP � 5 � 106 ( � � X. EXISTING TO REMAIN■n _id XXX XXXXX N 204 S.F. 164.61 S.FW / 0 = 2.24 /100 = 1.65 !■. z BXITS 1 B:EXITS 1 i /a� I4r# 4uru --- -� / EXISTING TO REMAIN• ( OPEN OFFICE \ -- 451 I W! 103 DANIE , 41.ye,1 732.05 S.F. '41, OREGON f ! 100 = 7.32 A B LOUVERED VENT 1 � II II I 0 B:EXITS 1 II CO ! _ 104 Door Schedule Client At:' r� ®) X46XX NOMINAL SIZE DOOR FRAME I 50.98 S.F. (IITYP. MARK Type GLAZING HRDW. REMARKS --'-'-'-'-'------'-'-'-------7 IIiFEC i EXEPT MA 'L FINISH ML FISH� ( ,' � SST L 1111 Q ., 4 104 3 -0 8 -0 1 3/4 ML P[i i� t' , __ 8'-6 5'-0 1 i 1� i r LEGEND LOBBY MTL TIMELY METAL FRAME C• // ��� ! j i0i���-- 102 o FF FACTORY FINISH ST STAIN D Irror—. , —1.� J.� , X4BXX X4BXX 1 127.48 S.F.> I 262.8 S.F. N © II /i00 = 2.63 ! /100 = 1.2 iirJJp L_—_—_—_—_—_—_—_—_—_—_—_—_—_—___!_—_—_—_—_—_�—_—CO L DISTA TH_ —_—_—B_EXITS 1—_—_J = B:EXITS 1 Door Hardware Electrical Symbols 6600 S.W. 105th Avenue TRAVEL DISTANCE 96 5 I 4 ,' — — -- Beaverton, Oregon 97005 [�� f !iwi4r rG�-I;-- '°'• �I ' �� ; �► GROUP 1�? 2 PAIR BUTTS STAT1 LOCKSET SCHi mil, ---.;4 A, ��AO" Alit AI 1 1 STOP IVES 630 4073 NEW DUPLEX 120 VOLT OUTLET Project: N EXISTING TELEPHONE/DATA OUTLET WITH PULL STRING TO TI for Alt GROUP 2 ABOVE CEILING 2 PAIR BUTTS STANLEY 652 FBB179 4;6 X 41/6 Superior l First Floor Plan 1 LOCKSET SCHLAGE 626 DORMA ND8OPD N NEW TELEPHONE/DATA OUTLET WITH PULL STRING TO Nip Al 1,716 SF • 1 STOP IVES 630 407J ABOVE CEILING 0 4 8 16 16 OCCUPANTS 1 LOUVRE Group WHERE TOP OF WALL TO STRUCTURE (1) 20 GA. 35/8" NOMINAL METAL 13535 SW 72nd-Suite 135 ABOVE IS LESS THAN 5'-9" PROVIDE STUD BRACING TO STRUCTURE Tigard, Oregon (1) BRACE AT 8'-0" 0/C TO ONE WITH (2) #8 SHEET METAL SIDE ONLY, STAGGER SIDES. WHERE SCREWS AT EACH END; PROVIDE DISTANCE IS GREATER THAN 5'-9", DOUBLE STUD BRACE WHEN Sheet Title PROVIDE BRACES EACH DIRECTION AT DISTANCE TO STRUCTURE ABOVE First Floor IS GREATER THAN 5'-9". BRACING 8'-0" 0/C TO BE PROVIDED WHERE DISTANCE 450 BETWEEN PERPENDICULAR Plan INTERSECTING WALLS OR HORIZONTAL BRACING BETWEEN I 141" WALLS EXCEEDS 8'-0" (DO NOT I ,1 EXTEND BRACING INTO EXPOSED ' VP STRUCTURE AREAS) L 13/2" x 11/2" x 16 GA x �`3" WITH (4) #8 SCREWS ..`.jMt - 0I SUSPENDED CEILING EACH SIDE .1_441 : r CASING BEAD USG 200-A ATTACH STUD TRACK ;:J. Revisions: TO BRACING THROUGH '� �'` OVERSIZED HOLE IN . :;`� 1 5/e" GYPSUM BOARD EACH SIDE SECURE TO STUDS WITH TYPE 'S' GRID �' SCREWS AT 5" - 7" 0/C 3Y2" ACOUSTIC BAIT r 1 24" 0/C STUD CHART_ 1��'' •362 S 125-18 TO 9'-11" I( ., •362 S 137-33 TO 17'-6" r 1I;: • 400 S 162-33 TO 19'-10" �� :< 4" RUBBER BASE 1 •600 S 162-33 TO 27'-7" I TYPICAL , ) i;• FOR ALTERNATE SIZES !`► POWER-ACTUATED FASTENERS: 1- 4 a> 0.145 0 x MIN. EMBED AT t 12" 0/C, WALL TO 22'-0" 0.145 0 x i' MIN. EMBED AT 6" 0/C, WALL TALLER THAN MILDREN DESIGN GROUP, P.C., 2014, ALL RIGHTS RESERVED© ( Wall to Suspended Ceiling 22 -0 THESE DRAWINGS ARE THE PROPERTY OF I MILDREN DESIGN GROUP, P.C., AND ARE NOT TO BE USED OR REPRODUCED IN ANY A 3"=1'-0" MANNER, EXCEPT WITH THE PRIOR WRITTEN '.1.t / PERMISSION OF MILDREN DESIGN GROUP, P.C. 1a1d-r8 Date 17 July 2014 Drawn by: Checked by: BK DAV Job Number: 114131 Sheet Permit Submittal - July 2014 A 1