'S2013 --0002J4 RECEIVED tico Worldwide www.tyco-fire.com FEB 1 9 2013 Contacts CITY OFTIGARD BUILDING DIVISION Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE The TYCO Series TY-B Sprinklers - 1, `� " Description described herein must be installed and maintained in compliance with " : " The TYCO Series TY-B, 5.6 K-factor, this document, as well as with the Upright(TY315)and Pendent(TY325) applicable standards of the National i Sprinklers described in this data sheet Fire Protection Association, in addition ` are standard response,standard cover- to the standards of any other authori A � t air age,decorative 5 mm glass bulb type ties having jurisdiction. Failure to do so SIM spray sprinklers designed for use in may impair the performance of these light, ordinary, or extra hazard, corn- devices. mercial occupancies such as banks, The owner is responsible for maintain- :' • hotels, shopping malls, factories, ing their fire protection system and refineries,and chemical plants. devices in proper operating condition. The recessed version of the Series The installing contractor or sprinkler TY-B Pendent Sprinkler,where appli- manufacturer should be contacted with cable,is intended for use in areas with a any questions finished ceiling.This recessed pendent i sprinkler uses one of the following: Sprinkler ,4 • A two-piece Style 15 Recessed - - ilk Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm)from �. the flush pendent position. Numbers (S I N S) pi- • A �t,�r;-_ • TY315 Upright 5.6K, 1/2"NPT ,, Escutcheon with recessed adjust- TY325 Pendent 5.6K, 112"NPT 1rf ment up to 1/2 inch (12,7 mm)from ,. � the flush pendent position. Technical • • The adjustment provided by the Finishes Recessed Escutcheon reduces the Data Sprinkler:Natural Brass,Chrome accuracy to which the fixed pipe drops Plated, Pure White(RAL 9010)and to the sprinklers must be cut. Signal White(RAL 9003). Approvals Recessed Escutcheon:White Coated, Intermediate level versions of Series UL and C-UL Listed Chrome Plated,or Brass Plated TY-B Sprinklers are described in FM and VdS Approved Technical Data Sheet TFP352.Sprinkler CE Certified Physical Characteristics guards and shields are described in Frame Bronze Technical Data Sheet TFP780. Maximum Working Pressure Button Brass/Copper 175 psi(12.1 bar) Sealing Assembly Stainless 250 psi(17.2 bar)' Steel w/TEFLON "The maximum working pressure of 250 psi Bulb Glass (17.2 bar)only applies to the listing by Un- Compression Screw Bronze derwriters Laboratories,Inc.(UL). Deflector Bronze IMPORTANT Discharge Coefficient Always refer to Technical Data K=5.6 GPM/psi112(80,6 LPM/bar112 Sheet TFP700 for the `INSTALLER Temperature Ratings WARNING" that provides cautions 135°F(57°C) with respect to handling and 155°F(68°C) installation of sprinkler systems and 175°F(79°C) components. Improper handling and 200°F(93°C) . installation can permanently damage 286°F(141°C) a sprinkler system or its components 360°F(182°C)t and cause the sprinkler to fail to operate in a fire situation or cause it tUL.C-UL,and VdS Approved only to operate prematurely. Page 1 of 4 JANUARY 2013 TFPI52 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11.1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* ter.. 1 I 1 tii 5._...— I'! 7/16" t �_-.`. (11,1 mm) — , nor :- _.____ 4 NOMINAL 2" .j \ _ I I_/._...- MAKE-IN (50.82 mm) 1 _ del �l (50,8 mm) (34,9 mm) I `J _ I WRENCH ,_—,_. FLATS 1 • 1/2"NPT** DEFLECTOR* — 2-7/8"(73,0 mm)DIA. �- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE Operation Installation The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. o glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubble is approximately 1/16 inch Upright TY315 and Pendent(TY325) inch (2,4 for the for the 360°F (1 2°C) ( ) ( ) inch (2,4 mm) for the 360°F (182°C) Sprinklers are intended for fire protec temperature ratings. sue: tion systems designed in accordance ' with the standard installation rules A leak-tight 1/2 inch NPT sprinkler , -)'' t recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 ` is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels 13, and FM Approval is based on the of torque may distort the sprinkler inlet requirements of the FM Loss Preven- and cause leakage or impairment of the IN SO ENSURE tion Data Sheets). Only the Style 15 sprinkler. IN G ENSURE or Style 20 Recessed Escutcheon,as ENGAGEMENT y Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening the sprinkler. Readjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED Upright Sprinklers ht and Pendent S SPRINKLER WRENCH p g p The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type - a 6 Sprinkler Wrench (Figure 2). With (73,0 mm) reference to Figure 1,apply the W-Type 2-1/4"DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF ---. (57,2 mm) • Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15.9 mm) Recessed Pendent Sprinklers l \ Nu ` FLUSH The Series TY-B Recessed Pendent 3/8±5/16" .1 Sprinklers must be installed in accor- (9,5±7,9 mm) , / r \ Ir % 1 dance with the following instructions. } l / `-d Step A.After installing the Style 15 or MOUNTING, ■ 1/8" Style 20 Mounting Plate,as applicable, SURFACE \ (3.2 mm) over the sprinkler threads and with / 7"---- 1 -- ------- -- pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into TY-6 PLATE 3/4"Ti 9,1 mm) the sprinkler fitting. Step B.Tighten the sprinkler into the FIGURE 4 sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) 7 Recessed Sprinkler Wrench (Figure WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 ----- (73,0 mm) 1 Nm). FACE OF I, Step C.After the ceiling is installed or SPRINKLER — 2-1/4"DIA. i the finish coat is applied, slide on the FITTING (57,2 mm) I Style 15 or Style 20 Closure over the Series TY-B Sprinkler and push the 5/16±1/4" I I 1 1/2"(12,7 mm) Closure over the Mounting Plate until (7,9±6,4 mm) , 1 -------------------- its flange contacts the ceiling. j - FLUSH ,I t Care and r.- ; ‘10 Maintenance MOUNTING j -SURFACE (3,2/m' m) ■ The TYCO Series TY-B, 5.6 K-factor, / -�-_- ;-- C Upright(TY315)and Pendent (TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) /....................__... Sprinklers must be maintained and PL ser- TY-B ATE 7/8"(22,2 mm) viced in accordance with this section. Before closing a fire protection system FIGURE 5 main control valve for maintenance SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) work on the fire protection system WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 that it controls, obtain permission to RECESSED ESCUTCHEON shut down the affected fire protection ' system from the proper authorities Modified sprinklers must be replaced. random sampling of close-up visual and notify all personnel who may be Sprinklers that have been exposed to inspections should be made. affected by this action. corrosive products of combustion, but Absence of the outer piece of an have not operated,should be replaced The owner is responsible a for the m P inspection,testing,and maintenance of escutcheon, which is used to cover if they cannot be completely cleaned their fire protection system and devices a clearance hole, can delay sprinkler by wiping the sprinkler with a cloth or in compliance with this document, as operation in a fire situation. by brushing it with a soft bristle brush. well as with the applicable standards The owner must assure that the Care must be exercised to avoid dam- of the National Fire Protection Associa- sprinklers are not used for hanging age to the sprinklers- before, during, tion(e.g., NFPA 25), in addition to the any objects and that the sprinklers are and after installation. Sprinklers dam- standards of any other authorities hay- only cleaned by means of gently dust- aged by dropping, striking, wrench ing jurisdiction. Contact the installing ing with a feather duster; otherwise, twist/slippage, or the like, must be contractor or sprinkler manufacturer non-operation in the event of a fire or replaced. Also, replace any sprinkler regarding any questions. inadvertent operation may result. that has a cracked bulb or that has lost Automatic sprinklers are recommended liquid from its bulb. (Ref. Installation to be inspected,tested,and maintained Sprinklers which are found to be leak- Section.) to a qualified Inspection maintained in _ ing or exhibiting visible signs of corro- by q P sion must be replaced. Thereafter, annual inspections per accordance with local requirements NFPA 25 are required;however,instead and/or national codes. Automatic sprinklers must never be of inspecting from the floor level, a painted, plated, coated, or otherwise altered after leaving the factory. TFP152 Page 4 of 4 P/N* 77 - XXX - X - XXX I � SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 570 5.6K UPRIGHT(1/2"NPT) TY315 4 SIGNAL WHITE(RAL 9003) 155 155°F(68°C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL 9010)" 175 175°F(79°C) 'Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-570-4.175-1 Eastern Hemisphere sales only 286 286°F(141°C) 360 360°F(182°C) TABLE A SERIES TY-8 UPRIGHT AND PENDENT SPRINKLERS — PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (SIN), K=5.6, (Upright or Pendent)Sprinkler Standard Response,(specify)temperature rating, (specify)finish,P/N(Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify')finish,P/N(specify') Specify:Style 20 Recessed Escutcheon with(specify')finish,P/N(specify') Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 a GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. *yen TEFLON is trademark of The DuPont Corporation.