FIRE PROTECTION
EQUIPMENT SUBMITTAL
tqco Worldwide
Contacts www.tyco-fire.com
Series TY-B, 5.6 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
- Standard Response, Standard Coverage
General NOTICE
The TYCO Series TY B Sprinklers .,:i• - ----
Description described herein must be installed __`
and maintained in compliance with ':
The TYCO Series TY-B, 5.6 K-factor, this document, as well as with the i
Upright(TY315)and Pendent(TY325) applicable standards of the National ` k
Sprinklers described in this data sheet Fire Protection Association,in addition "±
are standard response,standard cover- to the standards of any other authori-
age,decorative 5 mm glass bulb type ties having jurisdiction.Failure to do so .. ,
spray sprinklers designed for use in may impair the performance of these - l '
light, ordinary, or extra hazard, corn- devices.
mercial occupancies such as banks, — '
maintain-
hotels, shopping malls, factories, The owner is responsible for maintain- —
pp g ing their fire protection system and
refineries,and chemical plants. devices in proper operating condition.
The recessed version of the Series The installing contractor or sprinkler
TY-B Pendent Sprinkler, where appli- manufacturer should be contacted with
cable,is intended for use in areas with a any questions. ,
finished ceiling.This recessed pendent
sprinkler uses one of the following: Sprinkler "-- -%
• A two-piece Style 15 Recessed
Escutcheon with recessed adjust- Identification r;; -
•ment up to 5/8 inch (15,9 mm)from
the flush pendent position. Numbers (SINs) , -
• A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT
Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT
ment up to 1/2 inch(12,7 mm) from -
the flush pendent position.
The adjustment provided by the Technical Finishes
Recessed Escutcheon reduces the Data Sprinkler:Natural Brass,Chrome
accuracy to which the fixed pipe drops Plated, Pure White(RAL 9010)and
to the sprinklers must be cut. Signal White(RAL 9003).
Approvals Recessed Escutcheon:White Coated,
Intermediate level versions of Series UL and C-UL Listed Chrome Plated,or Brass Plated
TY-B Sprinklers are described in FM and VdS Approved
Technical Data Sheet TFP352.Sprinkler CE Certified Physical Characteristics
guards and shields are described in Frame Bronze
Technical Data Sheet TFP780. Maximum Working Pressure Button Brass/Copper
175 psi(12.1 bar) Sealing Assembly Stainless
250 psi(17.2 bar)* Steel w/TEFLON
*The maximum working pressure of 250 psi Bulb Glass
(17.2 bar)only applies to the listing by Un- Compression Screw Bronze
derwriters Laboratories,Inc.(UL). Deflector Bronze
IMPORTANT Discharge Coefficient
Always refer to Technical Data K=5.6 GPM/psi��2(80,6 LPM/barli2
Sheet TFP700 for the "INSTALLER Temperature Ratings
WARNING" that provides cautions 135°F(57°C)
with respect to handling and 155°F(68°C)
installation of sprinkler systems and 175°F(79°C)
components. Improper handling and 200°F(93°C)
installation can permanently damage 286°F(141°C)
a sprinkler system or its components 360°F(182°C)t
and cause the sprinkler to fail to
operate in a fire situation or cause it tUL,C-UL,and VdS Approved only
to operate prematurely.
. Page 1 of 4 JANUARY 2013 TFP1 S2
TFP152
Page 2 of 4
Components: *Temperature rating is ** Pipe thread connections per ISO 7-1
1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request.
2 - Button 5 - Compression STYLE 15 or 20
3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED
Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON
6* — I i
1
5 �.I 7/16' �=
(11,1 mm) ��1
• 4 NOMINAL rel 2" ll (I I)
MAKE-IN (50,8 mm) i /,-
2 lit 2" ) 1 — (34,9/mm) I ``vi,
3 (50,8 mm WRENCH
/ 1 FLATS
1/2"NPT** DEFLECTOR* I–"– 2-7/8"(73,0 mm)DIA. --
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 1
SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE
L, Operation Installation
--/
WRENCH RECESS
The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor,
expands when exposed to heat.When Upright(TY315)and Pendent(TY325)
(USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor-
END"A") fluid expands sufficiently to shatter the dance with this section.
glass bulb, allowing the sprinkler to
FIGURE 2 activate and water to flow. General Instructions
Do not install any bulb type sprinkler if
W-TYPE 6 the bulb is cracked or there is a loss of
SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler
held horizontally, a small air bubble
WRENCH Criteria should be present.The diameter of the
RECESS The TYCO Series TY-B, 5.6 K-factor, air bubble is approximately 1/16 inch
Upright(TY315)and Pendent(TY325) inc (2,4 for the for the 135°F (6 C) ( 2
Sprinklers are intended for fire protec- temperature mm) fogy t 360 F (182°C)
p p tem erature ratin s.
/ r tion systems designed in accordance
with the standard installation rules A leak-tight 1/2 inch NPT sprinkler
recognized by the applicable Listing joint should be obtained by applying a
It or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14
is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels
........• 13, and FM Approval is based on the of torque may distort the sprinkler inlet
PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the
INTO ENSURE tion Data Sheets). Only the Style 15 sprinkler.
ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for
WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch-
WRENCHING AREA pendent installations. eon plate by under-or over-tightening
the sprinkler. Readjust the position of
FIGURE 3 the sprinkler fitting to suit.
W-TYPE 7 RECESSED
SPRINKLER WRENNCH H Upright and Pendent Sprinklers
The Series TY-B Upright and Pendent
Sprinklers must be installed in accor-
dance with the following instructions.
Step 1. Install pendent sprinklers in
the pendent position; install upright
sprinklers in the upright position.
Step 2. With pipe-thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
TFP152
Page 3 of 4
. Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type 2-7/8"DIA.
6 Sprinkler Wrench (Figure 2). With (73,0 mm)
reference to Figure 1,apply the W-Type 2-1/4"DIA.
• 6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm)
Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER
19,0 Nm). FITTING
5/8"(15,9 mm)
Recessed Pendent Sprinklers i \ in FLUSH
The Series TY-B Recessed Pendent 3/8±5/16'
- Sprinklers must be installed in accor- (9,517,9 mm) _______ ,v •r % 1 I
dance with the following instructions. } /
`�'Step A.After installing the Style 15 or MOUNTING 1/8'
Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm)
over the sprinkler threads and with - ----— I
pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8'(34,9 mm)
threads,hand-tighten the sprinkler into TY-B PLATE 3/4"(19,1 mm)
the sprinkler fitting.
Step B.Tighten the sprinkler into the FIGURE 4
sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325)
7 Recessed Sprinkler Wrench (Figure WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15
3).With reference to Figure 1,apply the RECESSED ESCUTCHEON
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats. Torque 2-7/8"DIA.
sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 - (73,0 mm)
Nm).
FACE OF
Step C.After the ceiling is installed or SPRINKLER —2-1/4'DR.
the finish coat is applied, slide on the FITTING (57,2 mm) —
Style 15 or Style 20 Closure over the
Series TY-B Sprinkler and push the 5/16±1/4' 1/2"(12,7 mm)
Closure over the Mounting Plate until (7,9±6,4 mm)
its flange contacts the ceiling. i - FLUSH
=, I ._1_Care and f -
Maintenance MOUNTING 1 1/8"
SURFACE -� (3,2 mm)
The TYCO Series TY-B, 5.6 K-factor, -----
Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm)
Sprinklers must be maintained and ser- TY-B PLATE
viced in accordance with this section. 7/8"(22,2 mm)
Before closing a fire protection system FIGURE 5
main control valve for maintenance SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325)
work on the fire protection system WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20
that it controls, obtain permission to RECESSED ESCUTCHEON
shut down the affected fire protection
system from the proper authorities Modified sprinklers must be replaced. random sampling of close-up visual
and notify all personnel who may be Sprinklers that have been exposed to inspections should be made.
affected by this action. corrosive products of combustion, but The owner is responsible for the
Absence of the outer piece of an have not operated,should be replaced inspection,testing,and maintenance of
escutcheon, which is used to cover if they cannot be completely cleaned their fire protection system and devices
a clearance hole, can delay sprinkler by wiping the sprinkler with a cloth or in compliance with this document, as
operation in a fire situation. by brushing it with a soft bristle brush. well as with the applicable standards
The owner must assure that the Care must be exercised to avoid dam- of the National Fire Protection Associa-
sprinklers are not used for hanging age to the sprinklers- before,during, tion (e.g., NFPA 25), in addition to the
any objects and that the sprinklers are and after installation.Sprinklers dam- standards of any other authorities hav-
only cleaned by means of gently dust- aged by dropping, striking, wrench ing jurisdiction. Contact the installing
ing with a feather duster; otherwise, twist/slippage, or the like, must be contractor or sprinkler manufacturer
non-operation in the event of a fire or replaced. Also, replace any sprinkler regarding any questions.
inadvertent operation may result. that has a cracked bulb or that has lost Automatic sprinklers are recommended
Sprinklers which are found to be leak- liquid rom its bulb. (Ref. Installation to be inspected,tested,and maintained
ing or exhibiting visible signs of corro- Section.)from
a qualified Inspection Service in
sion must be replaced. Thereafter, annual inspections per accordance with local requirements
NFPA 25 are required;however,instead and/or national codes.
Automatic sprinklers must never be of inspecting from the floor level, a
. painted, plated, coated, or otherwise
altered after leaving the factory.
TFP152
Page 4 of 4
P/N* 77 - XXX - X - XXX
J I
SPRINKLER TEMPERATURE
• FINISH RATINGS
SIN 1 NATURAL BRASS 135 135°F(57°C)
570 5.6K UPRIGHT(1/2"NPT) TY315 4 SIGNAL WHITE(RAL 9003) 155 155-F(68°C)
571 5.6K PENDENT(112"NPT) TY325 3 PURE WHITE(RAL 9010)" 175 175°F(79°C)
•Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200`F(93°C)
tor example,77-570-4-175-1
Eastern Hemisphere sales only
286 286°F(141°C)
360 360`F(182'C)
TABLE A
SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS
— PART NUMBER SELECTION-
Ordering
Procedure
Contact your local distributor for avail-
ability.When placing an order,indicate
the full product name and Part Number
(P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify: Series TY-B (SIN), K=5.6,
(Upright or Pendent)Sprinkler Standard
Response,(specify)temperature rating,
(specify)finish,P/N(Table A)
Recessed Escutcheon
Specify:Style 15 Recessed Escutcheon
with(specify)finish, P/N(specify")
Specify:Style 20 Recessed Escutcheon
with(specify*)finish,P/N(specify*)
•Refer to Technical Data Sheet TFP770.
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700
Copyright m 2013 Tyco Fire Products,LP. All rights reserved. t�CO
TEFLON is trademark of The DuPont Corporation.
Dyna-Thread® - M-SSAT®
Submittal Data Sheet
Q Full Line Sch-40 Replacement Dyna-Thread—M-COATSpecifications
Dyna-Thread'"'—M-Coat sprinkler pipe represents an engineering NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR
advancement for the spi inkier pipe industry.It combines the safety In;mm In;mm Lbs/Ft kg/m Lbs/Ft;kglm Unthreaded Threaded
and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00
hydraulic advantages. 25 27.4 2.0 2.60 — —
11/4" 1.408 1.870 2.54 9.50 1.00
O Comparison to Schedule 40 32 35.8 2.8 3.78 — —
1'/" 1.639 2.290 3.22 9.14 1.00
Dyna-Thread'—M-Coate'inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — —
giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00
Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — —
approved UL, ULC,and FM for fire sprinkler applications.The life expectancy
of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall ® c®
thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— ,,,q•VC,
M-Coat facilitates smooth threading and lower maintenance costs.The exterior
of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for 4 American Made
extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available
and lighter weight,Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and
is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America.
(Underwriters Laboratory)term for the estimated life expectancy of a pipe joint.
This is based on the calculated wall thickness at the base of the first exposed OO Specifications &Approvals
thread,assumed to be the weakest point of the pipe length.Dyna-Thread—
M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A
and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All
sizes of Dyna-Thread—M-Coat are rated at 300 psi working
4 Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet,
More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre-action sprinkler systems and FM Approved for
better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems.Dyna Thread—M-Coat is approved for all
M-Coat is approved for standard hanger spacing(15 ft.0.C.),can be used as threaded couplings and welded outlets and is suitable for all
earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information).
is safer to weld on than many zinc coated lightwall threadable pipe products.
Dyna-Thread—M-Coat is more widely accepted than lightwall threadable
where Sch-40 is specified.
Project: Sprinkler Contractor: Date:
Engineer: Specification Reference: System Type:
Locations: Comments:
■••• "�11 Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com led • 16100 S Lathrop Ave • 1 1350 Norcom Rd. • 2525 N 27th Ave.
TUBE&//CONDUIT Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009
"A'="S a e2013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301
CID
17:: ...„ ..,, . .,.,.: ,
'y � c`, q '3,,,j rtivw 0,r.'trt
1 I. k.1 $.. S '
ryy . x b- 5
II:: . .' - ',.r + , , wt d t. +' w ,e,,�.
t 4 ' htirso ' r{ `- ` � yr`
I ! }�1+acw. g
"., sue `i „ t t Ni ,t . CG � ' ' ,,
r: 7 C. a , .y' t t„ !1-t.r ,�. A a �y, ' �
1.1 r �t. d• ,,„1 t f .4 t x'[4 6 ♦H it„'..
P.= i' 1 '' . ' • , ' • '-,e ` r I, . t�J l''r Mf
El.* . I t 4 i.
y I e 1 1 `
1 'i l .t$7 ' ' 4`.��,yR5"h,.,,y,n..;� +�,',4M
�, 1 y ,ea .irt u'- lsw. r.r3�'�{G � . #" ' ,a x•
= ' 1.7�
V''' Vii.!F e, {t;;•,t .`3' �,y ∎.'lei•&' y 1J�4�' 4 T*ic=
[ ,ice xa x ns { / a ';' ,AA
1+� �itv:ityi 4, +tT ,n;ti 9'F M ,. r+'m `� y °r -T "'E,
O � \ `•jUVA',' r Ai tx� .a[e,,,�c-, 4 " kn Mfr° dr r r �gg -
~
" W ,,>,:` ,,"4,',;.,-,',,.,,,:;',,,,i,. pad` ,ti+ ;* .
_1
•1_I
Cm) .. . . . _}
CI
I N T E R N A T I O N A L C 0 DPEI .')
Ductile Iron Threaded Fittings
Specifications
• <0> branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi
• Rated to 300 WSP
• Ductile iron castings conform to ASTM A536 C �L !IS
LISTED
• Fitting dimensions conform to ASME B16.3
• Bushings and plugs conform to ASME B16.14 41:;
• Fittings are 100% air tested APPROVED
• NPT threads on all fittings conform to ASME B1.20.1
• Independent lab verification that fittings meet applicable chemical&physical properties
• Manufacturing facilities are ISO 9001:2008 and ISO 14001
Temperature Working Pressure, Nonshock psiG
Degrees F 300# Class Threaded Fittings
-20 to 100 500
150 500
200 480
250 460
300 440
350 420
400 400
450 380
500 360
550 340
600 320
650 300
i
l Wile ron dings- , : I i i T
C 0 US
• APPROVED
LISTED
Fig. 35E 3- 90'Elbow
A
:-7�. ,_._•: .. Size A Packing Weight
it _. . _1111111_ Part Number
in in inner Master lb
+I . _-� 1/2 35E 3004 1.13 100 200 0.2
E != ; " 3/4 35E 3006 1.31 70 140 0.3
-'`4H` I ` A 1 35E 3010 1.50 40 80 0.5
I��; 1-114 35E 3012 1.75 25 50 0.8
1-1/2 35E 3014 1.94 18 36 1.1
2 35E 3020 2.25 10 20 1.8
2-1/2 35E 3024 2.70 4 8 3.2
Fig. 35RE3- 90°Reducing Elbow
B Size A B Packing Weight
Part Number
in in in Inner Master lb
K�,1t‘`1 C`rr. I i 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3
t i IMI 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4
A 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4
1-1/4x 1/2 35RE3012004 1.34 1.53 35 70 0.5
1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6
1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7
1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6
1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7
1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8
1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0
2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0
2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0
2 x 1 35RE3020010 1.73 2.02 16 32 1.2
2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3
2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5
2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2
2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5
Fig. 35F 3-45°Elbow
Size Part Number A Pack_ing Weight
A in in Inner Master lb
• - `/\\ �, 1/2 35F 3004 0.88 150 300 0.2
� *' 314 35F 3006 0.98 80 160 0.3
- y.;"; • ;_ -� 1 35F 3010 1.13 40 80 0.5
'i 1-1/4 35F 3012 1.29 25 50 0.7•',.=,,,.7..", A 1-1/2 35F 3014 1.44 20 40 1.0
` :_' 2 35F 3020 1.69 10 20 1.6
2-1/2 35F 3024 1.95 4 8 2.7
Fig. 35T 3- Tee
Size A Packing Weight
1 __ in Part Number in Inner Master lb
0.�'fi D'O'e.I A 1/2 35T 3004 1.13 80 160 0.3
R`� 3/4 35T 3006 1.31 30 60 0.5
t I= 1 1 35T 3010 1.50 25 50 0.7•;;t -^ 3' .�... 1-1/4 35T 3012 1.75 10 20 1.1
A A 1-1/2 35T 3014 1.94 10 20 1.5
2 35T 3020 2.25 6 12 2.4
2-1/2 35T 3024 2.70 4 8 4.3
111 SMITH-COOPER INTERNATIONAL* • TOLL FREE 1-S00-7o6-0076 • FAX 1323)Si10-4456 • w .sminccooper.wm
FDLCCJ www.tolco.coim
NIBCO' Revision 12/18/2008
Fig. 200 - "Trimline" Adjustable Band Hanger
c Ous usTEo
• Fig. 200R (Import) - "Trimline" Adjustable Band Hanger
w/Retainer Ring
Size Range — 1/2' thru 8" pipe
Material — Carbon Steel, Mil. Galvanized to G90
specifications �
Function — For fire sprinkler and other general piping - t""�J 1 g /
purposes. Knurled swivel nut design permits hanger ,� 3 '
adjustment after installation.
Features — - / 1
• (1/2" thru 2") Flared edges ease installation for ! B
all pipe types and protect CPVC plastic pipe j= 1' 1, j; .r- ; I
from abrasion. Captured design keeps adjusting A i! ;i' '- , ,/,'
nut from separating with hanger. Hanger is eas- t; ", '',diii :„......._____ily installed around pipe. ''_ --: A
• (2I/2" thru 8") Spring tension on nut holds it - -
securely in hanger before installation. Adjusting
nut is easily removed. Fig.2001"-2" Fig.200 21"-8"
Approvals — Underwriters' Laboratories listed
(1/2" thru 8') in the USA(UL)and Canada(cUL)
for steel and CPVC plastic pipe and Factory Mutual _- -`4%
Engineering Approved (3/4" thru 8"). Conforms to
Federal Specifications WW-H-171 E,Type 10 and 44 --
Manufacturers Standardization Society SP-69,Type {
10. B
■I -
Maximum Temperature — 650°F ;; B
Finish — Mil. Galvanized. Stainless Steel materials will 1,• ,
be supplied with (2) hex nuts in place of a knurl nub. /1 ....4---- 1,'
It Order By — Figure number and pipe size �/ A ;;
Note — Figure 200R (import)with retainer ring and A „` --- Av __
non-captured knurl nut. --_
Fig.200R 21"-8" Fig.200R 1/2"-2"
Dimensions •Weights
Pipe Rod Size Max.Rec. Approx.
+' Size Inch Metric A B Load Lbs. WtJ100
1/2 3/8 8mm or 10mm 31/2 2% 400 11
3/4 3/8 8mm or 10mm 31/2 21 400 11
• 1 3/8 8mm or 10mm 33/8 2% 400 12
11/4 3/8 8mm or 10mm 33/4 21/2 400 13
11/2 3/8 8mm or 10mm 3% 2% 400 14
2 3/8 8mm or 10mm 41 3 400 15
21/2 3/8 10mm 5% 41 600 27
3 3/8 10mm 5 7/8 4 600 29
31/2 3/8 10mm 7% 51/4 600 34
4 3/8 10mm 73/8 5 1000 35
5 1/2 12mm 91 61/4 1250 66
6 1/2 12mm 101/a 63/4 1250 73
• 8 1/2 12mm 13/8 83/4 1250 136
• OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330
- CUSTOMER SERVICE•800.786.5256 II
www.tolco.com