Permit (27) S20! 3 RECEIVED PHILLIPS NOV 4 2013 ELECTRONICS EST. 1952 CITYOFTIGARD BUILDING DIVISION 3247 NW 29th Avenue phillipsalarm.com Voice: 503-222-5083 Portland,Oregon 97210 Fax: 503-227-4992 Scope of Work 1. Install a Fire Alarm Control Panel 2. Install one manual pull station at the riser 3. Connection to sprinkler company provided and installed water flow and tamper switches 4. Install one smoke detector above the five alarm control panel 5. Install an electronic bell FIRE ALARM ACCESSORY 106 SILENT 5104B Fire Control KNIGHT Communicator by Honeywell The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines—eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard—the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800-328-0103. Model 5104B the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a 60 seconds, it will automatically six-zone fire control communicator switch to the other to report the 0 ' • , r providing digital fire reporting over failure. I . ordinary telephone lines, The communicator will signal eliminating the need for costly activation, restoration and trouble leased lines. It's UL 864 and NFPA conditions on any of six inputs. Ifs, 72 approved for monitoring local an application requires a different • IS evacuation controls. input configuration, the individual As a stand-alone unit, it can be input styles may be changed by used to monitor: using a Model 7181 Fire Zone Model 5104B • Sprinkler systems for waterflow, Converter Module. The 7181 also allows use of two-wire type smoke • hone line interface Automatic supervisory, and gate valve detectors, instead of the normal p tamper conditions. self tests every 24 hours with report four-wire contact type, for sent to central station. • Automatic fire detection systems automatic fire detection •for structures that are not Reports in SIA and most major applications. communications formats. required to have a fire alarm system but want property Features • 60 hours of standby power. protection (e.g. to call the fire • UL 864 Listed as an NFPA 72 • Operates on loop start phone lines department after hours). Central Station or Remote Station ahead of the building PBX system. • Monitors dry contact alarms, protected premise unit. • A single, programmable output is ry provided for alarm or dialer failed •trouble and supervisory outputs, FM approved. p ry p • Can be used as a stand-alone or as conditions(cannot be used for then transmits a separate code a add-on DACT. evacuation purposes). for each. The Model 5104B is fully • Six fully supervised inputs: one Class A(Style D)input, and five . supervised. Its microprocessor Class B (Style A)inputs. constantly runs programs to • Downloadable for remote monitor AC, standby battery, zone programming. . inputs and telephone line • Fuseless overload protection with connections. If a fault condition is automatic reset circuitry and fault detected, it sounds a local trouble indicators—eliminates the cause of audible and reports the condition to most field calls. FIRE ALARM ACCESSORY 5104B Fire Control Communicator Specifications Mechanical: Electrical Dimensions: 12.25"W x 14.5"H x 3.0"D Add-on Applications-UL Listed (31.1cm W x 36.8 cm H x 7.6cm D) Input: 120 VAC 60 Hz 40 watts Weight: 15 lbs.(6.75 kg) Current Color: Red Standby 50 mA Alarm 135 mA Optional Accessories: Stand Alone Applications 5230 Remote Annunciator/Programmer Input: 120 VAC 60 Hz 40 watts 5561 Download Package Standby: 12 volt 7 amp hour rechargeable battery 7181 Fire Zone Converter Module 5230 Remote Annunciator(three maximum per system) 7860 Telephone Connecting Cord for RJ31X Jack(2 required) 6712 12 volt,7AH rechargeable battery Load: 60 mA standby 120 mA alarm Communication Formats: SIA,SK 3/1, Sescoa 3/1,Contact ID, Indicator Lights(LEDs): SK 4/2, Radionics BFSK Power On(Green) Approvals: Trouble Silenced(Yellow) UL Listed-UL864/NFPA 72 Central and Remote Supervising Until Trouble is Cleared/Flashing=Supervisory Station Fire Alarm System Service. Dialer Failure(Yellow) FM Approved Telephone Line Fault(2 Red) CSFM Approved Inside Cabinet at L1 and L2 Inputs MEA Telephone Requirements: FCC Registration#:AC698R-17462-AL-E RINGER EQUIVALENCE 0.0B Type of Jack: RJ31X(2 required) Model 5230 Remote The Model 5560 SKSS Alphanumeric Annunciator Downloading Package The 5104B can be programmed Allows for remote programming through the use of the optional and status checking of the 5104. ■ Model 5230 Remote Alphanumeric Includes a 3 1/2-inch disk and riffenrw Annunciator. Programming options Silent Knight proprietary modem. ..o include: telephone numbers, Allows the installing company to reporting format, account number, view the default programming, loop response times (electronic modify it, and if necessary, 011101. retard), test time, output activation, troubleshoot the system. Designed 110111110191111111 user and installer codes. System to be used on an IBM or programming is stored in a non- compatible PC. The downloading volatile EEPROM chip which is software also contains programs for reprogrammable hundreds of times. other Silent Knight downloadable Model 5230 The 5104B accommodates up to products. 5 1/4-inch disks available three remote annunciators via a upon request. four-wire connection.A quick- connect plug allows temporary connection of the annunciator for programming. FIRE ALARM ACCESSORY 5104B Fire Control Communicator 120VAC 60 Hz UL-LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 5104B 6 Channel Silent Knight Communicator Model 5230 (optional) Remote Annunciator Alarm Contact (3 max per system) (N.O.Typical) Trouble Contact Tel. Line#1 To RJ31X (N.C. Typical) I► Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Add-On DACT Application SILENT KNIGHT MODEL 5104B 120VAC 60 Hz I 6 Channel Silent Knight Class A Input Communicator Model 5230 (supervised) (optional) Max 5 waterflow devices as per NFPA 72 Remote Annunciator (3 max per system) 0 0 Class B Inputs Wheelock (supervised) MB-G10-12-R Gate valve tamper or PIV I• supervisor-must connect Tel. Line#1 TO RJ31X normally open Model 6712 12VDC 7 AH ` Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Stand-alone Waterflow Application FIRE ALARM ACCESSORY 5104B Fire Control Communicator - SILENT KNIGHT MODEL 5104B 120VAC 60 Hz Silent Knight 6 Channel Model 5230 Class A Input O Communicator (optional) (supervised) Remote Annunciator (3 max per system) 0 0 Class B Inputs Wheelock (supervised) MB-G10-12-R Heat detectors,manual IIIIb (optional) pull stations and Tel. Line#1 To RJ31X contact type Model 6712 smoke detectors _ 12VDC 7 AH On Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application (For Communication Only) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary telephone line(number)at alternating supply shall be capable of supplying approved digital communicator to 24-hour intervals in accordance with power, under maximum normal load, transmit the fire alarm and supervisory NFPA 72. It shall sound a local trouble for 24 hours for central station or and trouble signals to a central station. signal if the telephone service is proprietary applications or 60 hours for The digital communicator shall be UL interrupted for longer than 60 seconds remote supervising station system or FM listed for fire reporting to a and it shall transmit a signal indicating application in accordance with NFPA central station and shall conform to the the loss of phone line service to the 72. requirements of NFPA 72. central station over the remaining The communicator shall be able to The digital communicator shall provide phone line.A signal shall also be transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format(Security Industry Association). six supervised detection circuits. One phone service.The shall be Class A(Style D)and five shall control/communicator shall be able to The alarm signals transmitted to the be Class B (Style A). The detection report the loss of either phone line central station shall indicate which of circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches, gate valve supervisory failed first. If both lines fail, a local zones are in trouble. Restoral from switches, thermal detectors and signal shall sound. alarm or trouble shall be capable of contact-type smoke detectors communicating to Silent Knight, and intermixed as desired and permitted by The control/communicator shall have other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours.The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines, seize the phone line setting a program within the panel. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA �� KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are PN 350349, Rev C1 by Honeywell subject to change without notice. For more information,contact Silent Knight ©2010 Honeywell International Inc. 12 Clintonville Road,Northford,CT 06472-1610. Phone: (800)328-0103, Fax:(203)484-7118. www.silentknight.com r • INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM ib Series SENSOR® Photoelectric Smoke Detector 3825 Ohio Avenue,St. Charles,Illinois 60174 1-800-SENSOR2,FAX:630-377-6495 Models: 2W-B,2WT-B,4W-B,4WT-B www.systemsensor.com ELECTRICAL SPECIFICATIONS 2-WIRE 4-WIRE System Voltage-Nominal: 12/24 12/24 Volts Non-polarized Min.: 8.5 8.5 Volts Max.: 35 35 Volts Max.Ripple Voltage: 30 30% peak to peak of applied voltage Max.Standby Current: 50 50 pA average Peak Standby Current: 100 —pA Max.Alarm Current: 130 20 mA 12 Volt Systems (For 2W-B and 2WT-B,panel must limit current) 130 23 mA 24 Volt Systems Alarm Contact Ratings: — 0.5 Amp @ 30 V AC/DC Alarm Reset Time: 0.3 0.3 sec Max.Start-up Capacitance: 0.1 —pF Latching Alarm:Reset by momentary power interruption Maximum Initial Start-up Time: 45 15 sec Alarm Verification° Start-up Time: 15 15 sec Assumes the panel's alarm verification reset time is 10 seconds or less.Should the alarm verification reset exceed 10 seconds,use the maximum initial start-up time. PHYSICAL SPECIFICATIONS Heat Sensor(Model 2WT-B and 4WT-B): 135°F(57.2°C) Freeze Trouble(Model 2WT-B and 4WT-B): 41°F(5°C) Operating'Temperature Range: 2W-B and 4W-B: 32 to 120°F(0 to 49°C) 2WT-B and 4WT-B: 32 to 100°F(0 to 37.8°C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158°F(-20 to 70°C) Diameter(including base): 5.3 inches Height(including base): 2.0 inches Weight: 6.3 oz. BEFORE INSTALLING Please read thoroughly System Sensor manual A05-1003,Applications Guide Installation of the 2W-B,2WT-B,4W-B,and 4WT-B detectors is simplified by for System Smoke Detectors,which provides detailed information on detector the use of a mounting base that may be pre wired to the system,allowing the spacing, placement, zoning, wiring, and special applications. Copies of this detector to be easily installed or removed.The mounting base installation is manual are available from System Sensor at no charge. further simplified by the incorporation of features compatible with drywall fasteners. NOTICE:This manual shall be left with the owner/user of this equipment. TWo LEDs on the detector provide a local visual indication of the detector's status: IMPORTANT.This detector must be tested and maintained regularly following TABLE 1:DETECTOR LED MODES NFPA 72 requirements.At a minimum,cleaning should be performed annually. Green LED Red LED GENERAL DESCRIPTION �— Models 2W-B and 2WT-B are 2-wire photoelectric smoke detectors; models' Power-up Blink 10 sec Blink 10 sec 4W-B and 4WT-B are 4-wire photoelectric smoke detectors. All models in- Normal(standby) Blink 5 sec — corporate a state-of-the-art optical sensing chamber and an advanced micro- Out of sensitivity — Blink 5 sec processor.The microprocessor allows the detector to automatically adjust its Freeze Trouble — Blink 10 sec sensitivity back to the factory setting when it becomes more sensitive due to Alarm — Solid contaminants settling in its chamber. In order for this feature to work prop- erly,the chamber must never be opened while power is applied to the smoke detector.This includes cleaning,maintenance or screen replacement.Should After an initial power-up delay, the red and green LEDs will blink synchro- it become necessary, the screen/sensing chamber is field replaceable. Mod nously once every ten seconds. It will take approximately 80 seconds for the els 2WT-B and 4WT-B also feature a restorable, built-in, fixed temperature detector to finish the power-up cycle(see Table 2). (135°F)thermal detector and are also capable of sensing a freeze condition if TABLE 2:POWER-UP SEQUENCE FOR LED STATUS INDICATION* the temperature is below 41°F. Condition Duration All i3 Series detectors are designed to provide open area protection.Two-wire Initial LED Status Indication 80 seconds models must be used with compatible UL Listed panels only. Initial LED Status Indication 4 minutes When used with an i3 Series compatible control panel or the i3 Series 2W- (if excessive electrical noise is present) MOD2 module(refer to installation manual D500-46-00),the 2W-B and 2WT-B are capable of generating a"maintenance needed"signal.The 2W-MOD2 can 'Refer to Electrical Specifications for start-up time in conjunction with panel indicate a need for cleaning,replacement,or a freeze condition(2WT-B only) alarm verification. at the control panel or module. D100-96-00 1 156-1800-012R • NOTE:lf,during p, • g power-u the detector determines there is excessive electri- • In wet or excessively humid areas,or next to bathrooms with showers. cal noise in the system such as those caused by improper grounding of the • In dusty,dirty,or insect-infested areas. system or the conduit,both LEDs will blink for up to 4 minutes before display Near fresh air inlets or returns or excessively drafty areas.Air condition- ing detector status(see Table 2). • ers, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. After power-up has completed and the detector is functioning normally within Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or ap- its listed sensitivity range,the green LED blinks once every five seconds.If the plicable codes for specific information regarding the spacing and placement detector is in need of maintenance because its sensitivity has shifted outside of smoke detectors. • the listed limits,the red LED blinks once every five seconds.When the detec- tor is in the alarm mode,the red LED latches on.The LED indication must not PACAUTION I be used in lieu of the tests specified under Testing.In a freeze trouble condi- Smoke detectors are not to be used with detector guards unless the combina- tion,the red LED will blink once every 10 seconds(refer to Table 1). tion has been evaluated and found suitable for that purpose. To measure the detector's sensitivity, the i3 Series Model SENS-RDR Infrared Sensitivity Reader tool should be used. (See Figure 4.) WIRING INSTALLATION GUIDELINES Models 2W-B and 2WT-B also include an output that allows an optional Model All wiring must be installed in compliance with the National Electrical Code, RA100Z Remote Annunciator to be connected. applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction. MOUNTING • Each i3 Series detector is supplied with a mounting base that can be Proper wire gauges should be used. The conductors used to connect smoke mounted: detectors to the alarm control panel and accessory devices should be color- coded to reduce the likelihood of wiring errors. Improper connections can 1. lb a single gang box,or prevent a system from responding properly in the event of a fire. 2. To a 31/2-inch or 4-inch octagonal box,or 3. To a 4-inch square box with a plaster ring,or The screw terminals in the mounting base will accept 14-22 gauge wire. For 4. Direct mount or to ceiling using drywall fasteners(Figure 2). best system performance,all wiring should be installed in separate grounded FIGURE is MOUNTING OF DETECTOR conduit;do not mix fire alarm system wiring in the same conduit as any other electrical wiring. Twisted pair may be used to provide additional protection al■ms■mmi against extraneous electrical interference. O Wire connections are made by stripping approximately 1/4-inch of insulation from the end of the feed wire,inserting it into the proper base terminal, and tightening the screw to secure the wire in place. TWO-WIRE COMPATIBILITY e'� System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product.For two-wire models 2W-B and 2WT-B,connect detectors only to compatible alarm control panels Wit =I if as identified by System Sensor's compatibility chart.This chart contains the current list of detectors and UL Listed compatible control units.A copy of this 50111-00 list is available from System Sensor upon request. The i3 Series heads and bases are keyed so that a 2-wire head will only mount to a 2-wire base, and a 4-wire head will only mount to a 4-wire base. The WIRING DIAGRAMS heads and bases are clearly identified as either 2-wire or 4-wire.When mount- FIGURE 3A:WIRING DIAGRAM,2W-B AND 2WT-B ing the i3 Series,ensure that the head is mounted to the correct base. TAMPER-RESISTANT FEATURE 2-WIRE+ lir"The i3 Series detectors include a tamper-resistant feature that prevents removal ZONE - RESISTOR from the mounting base without the use of a tool.To engage the tamper-re- sistant feature,cut the small plastic tab located on the mounting base(Figure -{RA10021-1 C 2),and then install the detector.To remove the detector from the base once it I '■; has been made tamper resistant,use a small screwdriver to depress the square tamper release tab, located on the skirt of the mounting base, and turn the ����� D00©� 2-WIRE detector counterclockwise. CONTROL , N 1. T -43'n I T. CONTROL o 1 a a 1 a a FIGURE 2:TAMPER-RESISTANT FEATURE PANEL Z $ 3 s T. ` T. 21N-B or /I 2W-B a DIRECT MOUNT 2Wr-B/ 2WT B HOLES — S0133-01 iiu, FIGURE 3B:WIRING DIAGRAM 4W-B AND 4WT-B IAUX OR +SMOKE RELAY , (EOLR-11 POWER - �.y SNAP OFF TAB FOR TAMPER LOCK '.I 11111111 RESISTOR TAMPER Qi 0❑•00 C00000 RELEASE TAB _ ,., .., . w - v .., . ,- 50226-00 4-WIRE DO NOT INSTALL DETECTORS IN THE FOLLOWING AREAS: PANEL S E. • In or near areas where particles of combustion are normally present 4w-B or 4W-B or such as kitchens;in garages (vehicle exhaust);near furnaces,hot water 4Wr-B 4wr-B heaters,or gas space heaters. 50134-01 • In very cold or very hot areas. D100-96-00 2 • 156-1800-012R 2-WIRE 12 DETECTOR WIRED IN STYLE D CONFIGURATION: B.SMOKE ENTRY TEST Hold a smoldering punk stick or cotton wick at the side of the detector and ACAUTION I gently blow the smoke through the detector until it alarms. Any 2-wire P smoke detector (2W-B, 2WT-B, 2WTA-B, or 2WTR-B) wired C.DIRECT HEAT METHOD(MODELS 2WT-B AND 4WT-B ONLY) in the Style D initiating device circuit (IDC) configuration requires the use Using a 1000-1500 watt hair dryer,direct the heat toward either of the thermis- of a 2W-MOD2 module. This is because fire alarm control panels vary by tors.Hold the heat source about 12 inches from the detector to avoid damage manufacturer on the implementation of Style D circuits.Therefore,the only to the plastic. • way to insure proper operation of 2-wire i3 smoke detectors (2W-B, 2WT-B, 2WTA-B,or 2WTR-B)on Style D 1DC's is to use a 2W-MOD2 module.Refer to NOTE:For the above tests,the detector will reset only after the power source the 2W-MOD2 installation manual,document D500-46-00,for Style D wiring has been momentarily interrupted. diagrams. The 2W-MOD2 installation manual may be downloaded from the If a detector fails any of the above test methods,its wiring should be checked System Sensor web site at www.systemsensor.com. and it should be cleaned as outlined in the Maintenance section. If the detec- tor still fails,it should be replaced. INSTALLATION Notify the proper authorities when the system is back in service. AWARNING I LOOP VERIFICATION(MODELS 2W-B AND 2WT-B ONLY) Remove power from alarm control unit or initiating device circuits before in- Loop verification is provided by the EZ Walk loop test feature. This feature stalling detectors. is for use with i3 Series compatible control panels or the i3 Series 2W-MOD2 module only. The EZ Walk loop test verifies the initiating loop wiring and NOTE:To install units so that corresponding LEDs are lined up, refer to the Provides visual status indication at each detector. "Green LED"indicator on the base. I. Ensure proper wiring and power is applied.Wait approximately six min- 1. Wire the mounting base screw terminals per Figure 3a or Figure 3b, as utes before performing EZ Walk test. applicable. 2. Place control panel or module in EZ Walk Test mode(refer to panel man- 2. Place detector on the base and rotate clockwise.The detector will drop ufacturei s manual or 2W-MOD2 manual D500-46-00). into the base and lock into place with a"click". 3. Observe the LEDs on each detector: 3. After all detectors have been installed,apply power to the alarm control unit. TABLE 3:EZ WALK TEST DETECTOR MODES 4. Test each detector as described in Testing. Green LED Red LED S. Reset all the detectors at the alarm control unit. 6. Notify the proper authorities that the system is in operation. Proper Operation Double blink 5 sec • ACAUTION I Out of Sensitivity — Double Blink 5 sec Dust covers are an effective way to limit the entry of dust into the smoke detec- Freeze Condition — Double Blink 10 sec for sensing chamber.However,they may not completely prevent airborne dust particles from entering the detector. Therefore, System Sensor recommends NOTE:The EZ Walk loop test must ma be used instead of alarm the removal of detectors before beginning construction or other dust produc- testing. ing activity.When returning the system to service,be sure to remove the dust covers from any detectors that were left in place during construction. MAINTENANCE NOTE:Before performing maintenance on the detector, notify the proper au- TESTING thorities that maintenance is being performed and the system will be tem- Detectors must be tested after installation and following maintenance. porarily out of service. Disable the zone or system undergoing maintenance NOTE: Before testing,notify the proper authorities that maintenance is being to prevent any unwanted alarms. Power must be removed from the detector performed and the system will be temporarily out of service.Disable the zone before performing maintenance of any kind. or system undergoing maintenance to prevent any unwanted alarms. 1. Remove the detector cover by turning counterclockwise. (See Figure 6.) Ensure proper wiring and power is applied.After power up.allow 80 seconds 2. Vacuum the cover or use canned air to remove any dust or debris. for the detector to stabilize before testing. 3. Remove the top half of the screen/sensing chamber by lifting straight up Test i3 Series detectors as follows: (Figure 5). 4. Vacuum or use canned air to remove any dust or particles that are pres- A.TEST SWITCH ent on both chamber halves. 1. An opening for the recessed test switch is located on the detector hous 5. Replace the top half of the screen/sensing chamber by aligning the arrow ing(See Figure 4). on the screen/sensing chamber with the arrow on the housing. Press 2. Insert a small screwdriver or alien wrench (0.18- max.) into the test down firmly until the screen/sensing chamber is fully seated. switch opening;push and hold. 6. Replace the detector cover by placing it over the screen/sensing chamber 3. If the detector is within the listed sensitivity limits, the detector's red and turning it clockwise until it snaps into place. LED should light within five seconds. 7. Reinstall the detector and test. (See the Testing section.) FIGURE 4:RECESSED TEST SWITCH OPENING AND SENS-RDR POSITION 8. Notify the proper authorities when the system is back in service. AT AN A SENS-RDR AT AN ANGLE ON THE OVAL AREA OR AT THE ._ CHAMBER OPEIIWG C BYTHEWORDPAPAV'• LED PUSH RECESSED • SWOON WTIA 0.13•MAX 1E DIA4ETER TOOL RECESSED TEST SWITCH SO1 35-00 • • D100-96-00 3 156-1800-012R • FIGURE 5:REMOVING/REPLACING SCREEN/SENSING CHAMBER REMOVABLE DETECTOR • COVER SCREEN/SENSING CHAMBER (TOP HALF) DETECTOH HOUSING 50136-00 • Please refer to insert for the Limitations of Fire Alarm Systems THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed smoke detector to be free from defects in materials Department,RA a ,3825 Ohio Avenue,St.Charles,IL 60174.Please include a and workmanship under normal use and service for a period of three years from date note describing the malfunction and suspected cause of failure.The Company shall not of manufacture. System Sensor makes no other express warranty for this smoke detec- be obligated to repair or replace units which are found to be defective because of damage, tor. No agent, representative,dealer,or employee of the Company has the authority to unreasonable use,modifications,or alterations occurring after the date of manufacture. increase or alter the obligations or limitations of this Warranty.The Company's obligation In no case shall the Company be liable for any consequential or incidental damages for of this Warranty shall be limited to the repair or replacement of any part of the smoke breach of this or any other Warranty,expressed or implied whatsoever,even if the loss detector which is found to be defective in materials or workmanship under normal use or damage is caused by the Company's negligence or fault.Some states do not allow the and service during the three year period commencing with the date of manufacture. exclusion or limitation of incidental or consequential damages,so the above limitation After phoning System Sensor's toll free number 800-SENSOR2 (736-7672) for a Return or exclusion may not apply to you.This Warranty gives you specific legal rights,and you Authorization number, send defective units postage prepaid to: System Sensor, Repair may also have other rights which vary from state to state. FCC STATEMENT ' This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and(2)this device must accept any interference received,including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular instal- lation, If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. D100-96-00 4 I56.1800-012R July 14, 2004 DF-50628• F-200 er44 FI re•LiTee Alarms BG-8 Series Manual Fire Alarm Pull Stations www.firelite.com Section' Conventional Initiating Devices GENERAL California The Flre•Lite Alarms BG-8 Manual Fire Alarm Pull Station 1 State Fire provides a single-action, normally-open contact alarm ini- Marshal tiating point for use with UL listed Fire Alarm Control Pan- LISTED '4 7150-0075:148 els. CS115 S711 M EA FEATURES ADA • Complies with Americans with Disabilities Act. 28-93-E • Sturdy metal construction. • Simple operation. • Operation does not require replacement of parts. • Drawing of flames on cover helps communicate pur- pose of this device to people who do not read English words. • Designed to prevent false alarms when bumped,shaken, or jarred. • Listed to UL 38. APPLICATIONS Designed for indoor use in atmospheres which are not po- �f tentially explosive. Use as a means of allowing anyone on the premises to turn in a non-coded alarm quickly, without �1 i chance of error. Typical uses include: I 1. Schools. 2. Hospitals. 3. Retail stores. 4. Industrial plants. 5. Warehouses. Compatible with any appropriate control panel to 1. Initiate local alarm signals. 2. Trip a municipal fire alarm box. 3. Start fire pumps. 4. Any other function that can be initiated or controlled by the closing of a switch contact. IRE OPERATION The stations feature non-break-glass operation. They are operated by a pull on the pull cover.This causes a key latch to act against a retaining mechanism until adequate force £. is applied to open the station.As the station opens, a switch gyp, is released to initiate an alarm. The retainer in Model BG- F I r. 1Te agn S 8 is a permanent, high-tensile, flat spring,which eliminates the need for a glass retainer.When so operated,the cover hangs down (and cannot be reset without use of a reset BG-8(shown full size) key)indicating that the station was used to initiate an alarm. OPERATED STATIONS CAN BE SEEN UP TO 100 FEET AWAY. The attractive design of the stations highlights their engi- Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep ISO 9001 • our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. C R T I F I E to For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Q U AL UA L IT IIT 8 MAflUFA Y SYSTE E M MS S Made in the U.S.A. Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. Q DF-50628•07/14/04 — Page 1 of 2 neered simplicity and unusual dependability; bumping, PRODUCT LINE INFORMATION shaking, or jarring will not activate the switch or circuit. In- Model Description structions for operation of the station are clearly marked on the front of the pull cover. BG-8 Manual Fire Alarm Pull Station. Single-action. The BG-8 Station is die-formed from 1/8"thick satin finish Normally-open contact. aluminum, with the operating instructions in raised letters. BG-8SP SPANISH Manual Fire Alarm Pull Station, with BG-8 contacts rated at 1 amp., 30 VAC, and 30 VDC. FUEGO(FIRE)and JALE(PULL)in large capital Master key fits all stations used in an installation of the letters. Single-action. Normally-open contact. same series. BG-2R Surface mounting backbox for BG-8 Series sta- INSTALLATION tions. One end tapped for 1/2" conduit. Color: The station mounts with two screws (supplied) to a stan MATCHING RED. dard single-gang electrical switch box. It can also be 17003 Key. mounted to a surface mount box. 6" wire leads are pro- vided for making easy connections. ARCHITECT/ENGINEERING SPECIFICATIONS DALE Manual Fire Alarm Stations shall be non-code, non-break ti glass type equipment with a key operated reset, and so RU LL designed that after actual Emergency Operation,they can- not be restored to normal except by use of a key. An oper- + ated station shall be designed such that upon activation, ) ;: it will be visually detectable at a minimum distance of one hundred feet, front or side. Manual Stations shall be con- structed � of die-formed aluminum, with operating directions provided on the front cover in raised letters.The word FIRE shall appear on the front of the stations in raised letters, five-eights inch high or larger. Stations shall be suitable / f for surface mounting on matching backbox, or semi-flush FUEGO mounting on a standard single-gang box or switch plate, and shall be installed within the limits defined by the Ameri- cans with Disabilities Act(ADA)dependent on manual sta- .„.. tion accessibility or per local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. ALAR/Y! FireLiTe ALarms - 80-ASP O 5/8" (1.59) 1-3J8" 1-1/2" -125) �� `��(3.49) (3.81 cm) +1 (10.16) 01/40'41ui,,, 3-1/4" -. (8.25) From previous To next station or station or % fire alarm --- - end-of-line control panel. device. BG-8/BG-8SP(Rear View) BG Series Backbox Page 2 of 2 — DF-50628•07/14/04 SYSTEM SENSOR SSM/SSV Series s>sT�rv► Alarm Bells System Sensor's SSM and SSV series alarm bells are low current,high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features Reliable Performance.The SSM and SSV series provide loud Approved for indoor and outdoor use resonant tones.The SSM series operates on 24VDC and are motor driven,while the SSV series operates on 120VAC utilizing a vibrating •Low current draw mechanism. •High dB output •Available in six-inch,eight inch,and ten inch sizes Simplified Installation.For indoor use,the SSM and SSV series mount to a standard four-inch square electrical box.For outdoor •AC and DC models applications,weatherproof back box,model number WBB,is used. -DC models polarized for use with supervision circuitry •Mount directly to standard four-inch square electrical box indoors The SSM and SSV series come pre wired,to reduce installation time. The SSM series incorporates a polarized electrical design for use with •SSM and SSV series come pre-wired supervision circuitry. Agency Listings �g'((i. ■■■/RRRR, MEA LISTED ® I approved au'! �5av 3U657S5 7135-16530317 3]1-11-L SSM/SSV Specifications Architectural/Engineering Specifications Model shall be a SSM or SW Series alarm bell.Bells shall have underdome strikers and operating mechanisms.Gongs on said bells shall be no smaller than nominal 678710-(specify size)with an operating voltage of 24VDC or 120VAC(specify by part number).Bells shall be suitable for surface or semi-flush mounting.Outdoor surface mounted installations shall be weatherproof(using optional WBB weatherproof electrical box).Otherwise bells shall mount to • a standard 4-square electrical box having a maximum projection of 2'/2-.Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction.Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal,and approved by Factory Mutual and MEA. Physical/Operating Specifications Operating Temperature Range —31°F to 140°F Operating Voltage SSM series:24 VDC SW series:120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm,General Signaling.Burglar Alarm Warranty 3 years Electrical Specifications Model Gong Diameter Nominal Voltage Operating Voltage Maximum Current Sound Output(dBA) (inches) Limit SSM24-6 6 Regulated 24VDC 16 to 33VDC DC-31.1 mA/FWR-53.5mA 82 SSM24-8 8 Regulated 24VDC 16 to 33VDC DC-31.1 mA/FWR-535mA 80 SSM24-10 10 Regulated 24VDC 16 to 33VDC DC-31.1 mA/FWR-535mA 81 SSV120.6 6 Regulated 120VAC 96 to 132VAC 53mA 85 SSV120-8 8 Regulated 120VAC 96 to 132VAC 53mA 82 5SV120-10 10 Regulated 120VAC 96 to 132VAC 53mA 82 Sound output measured at Underwriter Laboratories,as specified in UL464 Ordering Information UL/FM Model No. ULC/Canadian Model No. Description 55M24-6 SSM24-6A Bell,6",24VDC,Polarized,82dBA SSM24-8 SSM24-8A Bell,8-,24VDC,Polarized,80dBA 55M24-10 SSM24-10A Bell,10 24VDC,Polarized,81 dBA SSV120-6 SSV120-6A Bell,6-,120VAC,85dBA SSV120-8 SSV120-8A Bell,8-,120VAC,82dBA SSV120-10 SSV120-10A Bell,10-,120VAC,82dBA WBB Weatherproof back box for SSM and SSV series,when installed outdoors .SYSTEM 02011 em Sensor 3825 Ohio Avenue•St.Charles,IL 60174 Amci rka„o„ssu�atto a> ,s,natt MOM Mot snta corn ■ SENSOR Phone:800-SENSOR2-Fax:630-377-6495 anent p4tl1"'i°"°°°`nc1i°'g the West ve ondtesd'"'s'"" AoSd_t6a-ola-O&M-/2Bro • _ rwbar Frolecevaiues: SILENT Project Name:I Snyder Roofing Standby Hours:I 24 I KNIGHT Project ID: Alarm Mins: 5 I Prepared By: Phillips Electronics I Derating Factor: 12 I 5104 Calculations Date: 10/31/2013 I Voltage Drop Warning Version 05.21.10 Threshold%: 10 Panel ID: 5104 Model: 5104 Fire Communicator Max NAC Current: 0.75 Amps Location: Volts: 12 VDC Max Panel Current: 1.3 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Qty Standby Alarm &Type 1000 Ft. One-Way Ohms EOL �aDrop 5104 5104 Fire Comm. 1 0.075 0.135 5230 5230 LCD Remote 0.000 0.000 IDC-1 Smoke Detector 0.050 0.130 — IDC-2 Initiating Device Ckt 2 0.000 0.000 IDC-3 Initiating Device Ckt 3 0.000 0_000 IDC-4 Initiating Device Ckt 4 0.000 0.000 IDC-5 Initiating Device Ckt 5 0.000 0.000 IDC-6 Initiating Device Ckt 6 0.000 0.000 NAC-1 Notification Appl Ckt 1 0.000 0.000 #12 Solid 1.59 I 0.00 I 20.40 1 0.00% Total Standby Current(Amps) 0.125 0.135 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 3.000 0.011 Total Alarm AH Required Total Combined AH Required 3.01 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required_ 3.61 Configure Circuits Print Page