Loading...
Report NA-€C201 3- cot(G -1 !o3.A SW D 1,107 MITSUBISHI 3S0 ELECTRIC , COOLING & HEATING M-SERIES SUBMITTAL DATA: MSY-GE12NA-8 & MUY-GE12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference [ 'Approval ❑Construction System Designation: Schedule No.: lir ll � t _ `:43. Indoor Unit MSY-GEI2NA-8 Z I I • ill I p Pill pr-.9 Most Efficient s ,u::, g"II 2013 Wireless Remote Outdoor Unit:MUY-GE12NA ENERGY STAR www,rrn�rpyshcor Controller GENERAL FEATURES • Wall-mounted indoor unit • Standard Hybrid Catechin Prefilter is included with indoor unit • Quiet operation • Auto fan speed control:Quiet,Low,Medium,High,and Super High; • Hand-held Wireless Remote Controller • Indoor unit powered from outdoor unit using A-Control • Auto restart following a power outage • Anti-allergy Enzyme Filter • Limited warranty:five years parts and seven years compressor ACCESSORIES Outdoor Unit ❑ Drain Socket Assembly(MAC-860DS) Indoor Unit ❑ Condensate Pump(230V;SI3100-230) Controller Options ❑ Wireless Wall-mounted Remote Controller Kit(MHK1)* ❑ Portable Controller(MCCH1)* ❑ Outdoor Air Sensor(MOS1)* 'See Submittal for information on each option. ❑ Wired Wall-mounted Controller (PAR-21MAAU requires MAC-3331F) ❑ System Control Interface(MAC-3331F) ❑ Remote Temperature Sensor(M21-JKO-307) ❑ Lockdown Bracket for Hand-held Controller(RCMKP1 CB) 410/ iR Specifications are subject to change without notice. C 2013 Mitsubishi Electric US,Inc. ,J •y SPECIFICATIONS: MSY-GE12NA-8 & MUY-GE12NA . 1 Cooling* Indoor Unit Rated Capacity 12,000 Btu/h MCA 1 A Minimum Capacity 3,800 Btu/h Blower Motor(ECM) 0.76 F.L.A. SEER 20.5 Btu/h/W Airflow(Quiet-Lo-Med-Hi-Super Hi) Total Input 960 W Cooling 145-170-237-321 -399 Dry CFM 109-134-201 -286-364 Wet CFM *Rating Conditions per AHRI Standard Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Cooling 19 22-30 37-45 dB(A) Cooling I Outdoor:95°F(35°C)DB/75°F(24°C)WB DIMENSIONS UNIT INCHES I MM W 31-7/16/799 D 9-1/8/232 Electrical Requirements H 11-5/8/295 Power Supply 208/230V, 1-Phase,60 Hz . Breaker Size 15 A Weight 22 lbs./10 kg External Finish Munsell No. 1.0Y 9.2/0.2 Voltage Field Drainpipe Size O.D. 5/8"/15.88 mm Indoor-Outdoor S1-S2 AC 208/230V Indoor-Outdoor S2-S3 DC±24V Outdoor Unit Indoor-Remote Controller MKH1 DC 3V Compressor DC Inverter-driven PAR-21MAAU DC 12V MCA 12 A PAR-FL32MA DC 3V Fan Motor(ECM) 0 50 F.L.A. Sound Pressure Level OPERATING RANGE Cooling 49 dB(A) Indoor Intake Air Outdoor Intake Air DIMENSIONS INCHES/MM Temp. Temp. 90°F(32°C)DB W 31-1/2/800 Maximum 73°F(23°C)WB 115°F(46°C)DB D 11-1/4/286 Cooling 67°F(19°C)DB H 21-5/8/549 Minimum 57°F(14°C)WB 14°F(-10°C)DB Weight 77 lbs./35 kg External Finish Munsell No.3Y 7.8/1.1 Refrigerant Type R410A Refrigerant Pipe Size O.D. Gas Side 3/8"/9.52 mm Liquid Side 1/4"/6.35 mm Max.Refrigerant Pipe Length 65 ft./20 m r Max.Refrigerant Pipe Height Difference 40 ft./12 m Connection Method Flared Notes Specifications are subject to change without notice. ©2013 Mitsubishi Electric US,Inc. e - §. DIMENSIONS: MSY-GE12NA-8 & MUY-GE12NA iMSY-GE12NA-8 Unit: inch 7/16x1 Oblong hole 7/16.13/16 Oblong hole 3-1/8 8-7/8 1 8-7/8 ` 3-1/6 m Installation plate — — 1; !:— r _ 31-7/16 -— — -- - 'r 30-15/16 1/4 °D o � _ d III • A � �' 11t _ 8.1/9 8-1/8 m ai ' '2- + 13-5/16 13-9/18 — 2.1/8 9-1/8 Air in Wall hole.2-9/16 3/16 ,01.1111 . --Indoor unit " Installation•late P1•In•_ i m m TO ._/ , Ir �, 1 7, 5 (II_ II •�= -.. 1-3/4 < 15/8 m m 1-15/16 24-3/8 5.1/8 '.---- :gm r N \Drain hose 0 4-3/8 2-5/16 I I"__ IF3/4 m Air out SInsulation e1-3/8 0.0 —IT) - - ( 1 r_ c Liquid line e1/4 19-11/16(Flared connection r1/4) a Gas line a3/8 16-15/16 2-3(16 1-15/161 I _ (Flared cornectlon:a3/8(0EOWDI1211A),.1/2(0815/16NA)) Drain hose Insulation e1-1/8 0.D Connected part e5/9 0.D MUY-GE12NA Unit: inch 15-3/4 Drain hole�1-5/8 REQUIRED SPACE ° Basically open 4 inch or more...s.i Air in without any obstruction in front II= and on both sides of the unit. coAir in cJ ( p . c.i t rn o11no1e �, IIi hi in a- 1/4 oroore b Air out Ai 1-9/16 ' xi 1. a v.I h• _ >> >� 7/8 \mot M°16 ,'t 147n•or�ore sin• r handle 29/32 11-1/4 17/32 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII itie IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Open two sides of left, IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I ( right,or rear side. co IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII M IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII : _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII - _ uguumuuuuuuuumunuuuu Y �� 2g(3y —' 6y :�= Gaslpip :3/8(flared)(GE09H2) _ � 1/2(flared)(GE15) 15.15/1§.4 19-11/16 — 31-1/2 > -x 2-23/32 6-23/32 ArtMITSUBISHI s, ELECTRIC ti' CERTIFIED,- COOLING & HEATING ....enndveae.y.erg PARTNER Live Better 1 Unitary 1 Small 2101240 1340 Satellite Boulevard c.mv......w.�,........w..r 1EGUS .-.e.-u.. rs Suwanee,GA 30024 Tele:678-376-2900•Fax:800-889-9904 Intertek Toll Free:800-433-4822 www.mehvac.com FORM#MSY-GE12NA-8–MUY-GE12NA-201304 Specifications are subject to change without notice. 0 2013 Mitsubishi Electric US,Inc.