Loading...
Specifications "FPS 2-012— Oo t Cs �la� a SW DL -hafl + /00 14795 S.W. 72nd t DELTA PORTLAND, OR 97224 PHONE 503-620-4020 -FIRE INC. CCBIt 641674 1058 0CT CITY OF TIGARD B DfNG DIVISION Pactrust Business Center Indio Inc. DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM • SHOP DRAWING AND SUBMITTAL REVIEW D CONFORMS TO DESIGN C MCEPT U =FORMS TO DESIGN CONCEPT EXCEPT AS NOTED NONCONFOININ4,WINE AND RESUBMIT O REVIEWED THIS SUBPQTTA& HAS BSI NEVEM rat OMAN. mMFORE+ANCE WITH THE DESDGN CONCEPT OF THE PIt)W AND GENBTAL COMPLIANCE WITH THE D*ORMATION G1YB1 N THE CONTRACT DOCUMENTS. ANY ACTION 9 15 SUIUEtT TO THE REQUIREMENTS OF THE IMAMS, SPECIFICATIONS AND APPEICAI E CODES,ALL OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS iIESFONSTBtE FOR QUALITY DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE OD SITE), FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, COORDINATION OF THE WORK WITH THAT OF AU. OTHER TRADES AND THE SATISFACTORY PERFORMANCE OF THE MAX_ PacTnj st DE-. /0/2 October 23, 2012 125049 FIRE PROTECTION CONTRACTORS D 14795 S.W. 72 Avenue PORTLAND, OR 97224 PHONE 503-620-4020 • FIRE, INC. CCB# 64 74 1058 S •rin kit e r e a s FIRE PROTECTION CONTRACTORS Bulletin 014 Rev. F co Re1iabI ModLiEies cp QuicStany Model Fl FR56 Sprinkler Types Standard Upright o ,; - Standard Pendent �� --~ Conventional ;, 40 1 Vertical Sidewall Horizontal Sidewall � ° Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Upright Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types - Standard Pendent OA . a it Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada(cULus). A 2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH UL Listing Category x£ Sprinklers, Automatic&Open (VNIV) C e___•_.e4 jk - Quick Response Sprinkler j , t l' IF. Product Description Reliable Models F1FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a Stan- Horizontal Sidewall Recessed dard sprinkler with the attractive low profile of a decorative Pendent/F1/F2 sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- ' "'=- ,. klers have demonstrated response times in laboratory tests r • , N.,T which are five to ten times faster than standard response t volt sprinklers. This quick response enables the Model F1FR56 P q P - k It. . 'Series sprinklers to apply water to a fire much faster than -.._°;, ...A` standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount Recessed Recessed of special fluid hermetically sealed inside a precisely manu- Horizontal Sidewall Pendent/FP factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Application At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be expands,forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec- uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lat- to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. ute the discharging water. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler IdenSfication Number (SIN) Orifice Size Height Organization • US Metric Upright r Pendent Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,2,3,4 RA142501 J RA1414 0x2) Conventional-Install in Upright or Pendent Position 15mm1'1 1/2"NPT(R'/2) 5.6 80 57mm 3,4 RA1475 (1)cULus listed corrosion resistant(Polyester coated)sprinkler. (2)Polyester coated FM approved sprinkler. 33 0 :. r - Upright Pendent Conventional Model Fl FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number • Orifice Size US Metric Height (SIN) 1"(15mm) 1/2" NPT(R1/2) 5.6 80 2.25"(57mm) RA1414 (" Refer to escutcheon data table for approvals and dimensions. 2 5/6"DIA. [66.7mm] 1 1/4•HOLE Du. HOLE IN CEILING ~ (572mm] r 75/16"DM 2 5/16"0L4. [58.7mm] F (49.2mmj CUP ___=_a L==t'_==— r I 1 7"K 1/2•REDUCER I _ _ I 1"X I/2 REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER I I I I WRENCH BOSS \1 III ///�/7J 1 r -l 1 `\ -- / -I—�� 1 t_„=�I.1=.1_.7 FACE OF FITTING ro('1 CEILING (11 CE/UNG DIMENSION AD/us7MEN llp`o !111/1//%L 1 t FACE OF G I`i II 'IiI 1 "&Ilid ONIp1W.,ION(1J 4 (J2mmJ IM I L (J , /. A r) ADJUSTMENT 1 27/31-D9L 014FGO7 ••-— -• -- (72.2mmJ 074Fa01 • L (1)REFER TO F1 k F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS (IJ REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Model F1FR56/F1 or F2 Model F1FR56/FP 2. - Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: ' Nominal Nominal K Factor Sprinkler Approval Sprinkler Orifice Thread Size US Metric Height Organizations Identification Numbers(SIN) 'h"(15mm) 1/2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 1,2,3,4 RA1485 15mm 'h"NPT(R1/2) 5.6 8.0 2.25"(57mm) 40) ")LPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance (Min. -Max.) ipit Upright 4"(102mm) 12"(305mm) Pendent 4"(102mm)-12"(305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Height and Type of Approval Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers(SIN) Hazard 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435 FACE OF FITTING(1) TO FACE OF CEILING DIMENSION 1 1/4"MIN. 2 1/4"HOLE DLA. [31.8mm] 4"-12" �. (57.2mm] 1/B" [101.6mm-304.8mm] (3.2mmJ CEILING TO 1"X 1/2"REDUCER DEFLECTOR -II% WV _ _ �_ a - r L C -f1� 1 15/16"DLA. l I I II (49.2mm] 1-i 1 I II - �4 2 27/32"DN. L I`-'----1---i -1--.Al [72.2mm] 1111 All Horizontal Sidewall l i TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER `\. WRENCH BOSS. II - -.I La-ADJUSTMENT ot,W50J4 (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. • (2) FM APPROVED FOR 4" - 6"(101.6MM - 152.41,114 CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model Fl FR56 Quick Response Concealed Pendent Sprinklers : Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Sprinkler Orifice Size Model Ambient Color Approvals Identification US Metric Sprinkler Cover Temp Number(SIN) '/z"(15mm) 5.6 80 '/" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1,2 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 2,4111 RA1414 1/2"(15mm) 5.6 80 '/2" NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1,2 RA1414 1/2"(15mm) 5.6 80 1/2"NPT F1FR 200°F/93°C 165°F/74°C 100°F/38°C ' Green 1,2 RA1414 (')For VdS only= 155°F/68°C Norbulb and 1/2"[12,7mm]adjustment. 7-x 1/2"REDUCING TEE OR ELBOW ---°----.. I"x 1/2"REDUCING -- s— m Tr-------- TEE OR ELBOW -- •—•----fN—'———'-------X44--'--- ---—..n. �.._..-- 1--1 i r--,— 2 5/8"DIA. --._..11 I •ll — —2 5/16"DIA — HOLE IN CEILING —,---1 _— 2 5/8`01A. 2 5/16"DIA — HOLE IN CEILING CUP -_�� I J— l'V•ul 1 1/2"MAX. CUP ��—�� 4 p I _-- ' 1 1 2"MAX. ,f I I FACE OF FITTING C!Z-1l / NI H �1 TO FACE OF CEILING ---•- ( I FACE OF FITTING T,-;T;� DIMENSION I'� �l TO FACE OF CEILING �. ; j..:,*,;;. :i 1T ::-...CEILING ! { `111�i1 _. D!M£0SION`Iii— CEILING \\. %�� -11111 ii 1/2" MAX. 15/16" 5/16"MAX. �^ 3/4" COVER ADJUSTMENT COVER ADJUSTMENT COVER PLATE— COVER PLATE— I t ASSEMBLY 3 5/16" DIA. t ASSEMBLY 3 5/16"DIA. ■SPRINKLER / SPRINKLER / 1/2" ADJUSTMENT 5/1 6" ADJUSTMENT 01"40: Figure 1 Figure 2 Installation Aid A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac- • important: The F1FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet- plate is not an FM Approved combination. ed by the installation of the attractive, low profile, 135°F Installation (57°C) or 165°F (74°C) rated Model CCP push on cover Quick response sprinklers are intended for installation plate assembly. The cover plate and sprinkler cup as- as specified in NFPA 13. Quick response sprinklers and semblies are joined using a cover plate skirt with flexible standard response sprinklers should not be intermixed. tabs for threaded engagement. A choice of two cover The Model F1FR56 Recessed Quick Response Sprin- plate assemblies provide either 1/2" (13mm)or 5/16" (8mm) klers are to be installed as shown.The Model Fl or F2 Es- of cover adjustment. cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have to be used with the Model F1FR56 Sprinklers. The use positive pressure in the space above. of any other recessed escutcheon will void all approvals After a 25/6" (67mm) diameter hole is cut in the ceil- and negate all warranties. ing, the sprinkler is easily installed with the Model RC1 When installing Model Fl FR56 Sprinklers, use the Mod- Wrench. A Teflon* based thread sealant should be el D Sprinkler Wrench. Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1 installing F1FR56 Recessed Pendent Sprinklers. Any Wrench is then used to engage the sprinkler wrenching other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting. When NOTE: A leak tight 1/2" NPT (R1/2) sprinkler joint can inserting or removing the wrench from the sprinkler/cup be obtained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). assembly, care should be taken to prevent damage to Do not tighten sprinklers over maximum recommended the sprinkler. DO NOT WRENCH ON ANY OTHER PART torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER. The cover plate is then pushed - klers. onto the cup. Final adjustment is made by hand turning The Model Fl FR56/CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact 1" orifice, 1/2" NPT (R1/2), 135°F (57°C), 155°F (68°C), with the ceiling. Cover plate removal requires turning in 175°F (79°C) or 200°F (93°C) Model F1FR56 Pendent the counter clockwise direction. *DuPont Registered Trade Mark 4. After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent impediment to the space above. Conventional Concealed cover plate/cup assemblies are listed only Recessed Pendent for use with specific sprinklers. The use of any other con- Vertical Sidewall cealed cover plate/cup assembly with the Model Fl FR56 Horizontal Sidewall Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation. REMOVE THIS PROTECTION AT THE TIME Finishes (1) THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this Standard Finishes time may leave the bulb vulnerable to damage. RASCO Sprinkler Escutcheon L Cover plate Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated(4)(5) White Painted THE PROTECTORS. Special Application Finishes Sprinkler Escutcheon Cover plate Temperature Ratings Bright Brass(3) Bright Brass Bright Brass Sprinkler Black Plated Black Plated Satin Max.Ambient Black Paint Black Paint Off White Classification , Temperature Temp. Bulb Color Off White(2) Off White Black Paint °C °F Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100°F(38°C) Orange (1) Other finishes and colors are available on special order. Ordinary 68 155 100°F(38°C) Red Consult the factory for details. Intermediate 79 175 150°F(66°C) Yellow (2) cULus Listed only. Intermediate 93 200 150°F(66°C) Green (3) 200°F(93°C)maximum. High(1) 141 286 225°F(107°C) Blue (4) cULus listed"corrosion resistance"applies to SIN Numbers ("Not available for recessed sprinklers. RA1425(Upright)and RA1414(Pendent)in standard black or white. (5) FM Approvals finish as"Polyester coated"applies to SIN Number Escutcheon Data (1) RA1414(Pendent)in standard black or white. Faced Esaicheon Approvals Adjustment Ceding W U Ordering Information Model Dknension Dimension Specify: Fl 1,3,4 Max Recess 11/2"(38.1m) 3/16"-15/16' 1. Sprinkler Model MiRecess 3/4"(19.1m) (5rrm-24mm) 2. Sprinkler Type F2 1,2,3,4 Max Recess 11"(38.1mm) 3/16'-"/16 3. Orifice Size min Recess 1"(25rrm) (arm 17m) 4. Deflector Type FP Push onl Max Recessed 7/16"(11m) 11/2" (38.1 mm) Thread-off 1,4 Min Recessed 75/16(24mm) 1"(25.4mm) 5. Temperature Rating (1)SIN:RA1435-cULus and FM permits use with Fl or F2 escutcheons for light 6. Sprinkler Finish hazard only. 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Maintenance 9. Cover plate Model The Models F1FR56 and F1FR56 Recessed Sprinklers 10. Cover plate Thread size should be inspected quarterly and the sprinkler system 11. Cover plate Temperature maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment sprinklers with soap and water, ammonia or any other 13. Cover plate Finish cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has Note:When Model F1FR56 Recessed sprinklers are ordered,the sprin- been painted (other than factory applied) or damaged klers and escutcheons are packaged separately. in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would • cause improper operation or non-operation. 5. - Reliable. . . For ProtectiOn Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices . • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gaugesldentification signs • Electrical sprinkler alarm switches • Fire department connection • Water flow detectors The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled (80000))4381-6105858 Sales Offices Paable aper per (8 848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 02/11 P/N 9999970300 Bulletin 153 Rev.L co Model F3 c ® Dry Sprinklers c r— Features --- -' 1. The Model F3 Sprinkler utilizes Belleville Spring I 0 fi, 1 Closure Technology 2. Styles available for Model F3 Dry Sprinklers: • Pendent • Recessed Pendent • Concealed • Horizontal Sidewall j • Recessed Horizontal Sidewall ir - 3. 11/2"" (38mm) escutcheon adjustment on pendent l sprinkler. `' 4. 1/2" (13mm)escutcheon adjustment on recessed sprin- Pendent Pendent/HB kler with push-on/thread-off FP Model escutcheon (See Fig. 1) (See Fig. 2) ring. _ 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push-on/thread-off CCP cover. 6. Attractive appearance. Employs 5mm frangible glass bulb and galvanized nipple. 7. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51mm - to- 1219mm), in I 1/4" (6mm) increments. 8. Available in a variety of plated and painted finishes. Ra ; 9. Polyester Coated Corrosion Resistant Sprinklers. - U.S. Patent Numbers 5,775,431 and 5,967,240. Recessed FP Pendent Concealed (See Fig. 3) (See Fig. 4) Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada(cULus). Style Response Sprinkler Hazard �`'` ,, System Type _ "...,::�€ Pendent 'r 4,,,, Recessed Pendent CCP Concealed Wet Pipe Light (R5314) Standard Dry Pipe Ordinary Horizontal Sidewall All Preaction Recessed Horizontal Sidewall Horizontal Sidewall Horizontal FP Sidewall (R5334) 2. Certified by FM Approvals (See Fig. 5) (See Fig. 7) Style Response Sprinkler Hazard System Type Pendent Light Recessed Pendent Wet Pipe Ordinary, CCP Concealed Standard Dry Pipe Groups (R5314) All Preaction 1&2 � Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Standard Dry Pipe Light i', (R5334) All Preaction 3. NYC MEA 258-93-E 4. LPCB Approved, CE listed 0832-CPD-2006 Horizontal Sidewall/HB (See Fig. 6) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3 Dry Pendent Sprinkler "A" Dim. 2"to 48"(51mm to 1219mm)in 14"(6mm)increments - Finishes',, Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. - I Bronze Brass(51 Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Rating Temp. White Polyester(4) White Ordinary 135°F (57°C) 100°F (38°C) Orange . Lead Plated(2) Ordinary 155°F (68°C) 100°F (38°C) Red Wax Coated[2][3) Intermediate[1) 175°F (79°C) 150°F (66°C) Yellow Wax Over Lead(2)(3) Intermediate 200°F (93°C) 150°F (66°C) Green (1)Other finishes and colors are available on special order.Consult factory High 286°F(141°C) 225°F(107°C) _ Blue for details. Sprinkler can and escutcheon fabricated of brass for better weather (2)155°F(68°C)to 200°F(93°C)rating only. resistance in exterior applications. (3) 212°F(100°C) brown wax may be used on 286°F(141°C)sprinklers when maximum ceiling temperatures do not exceed 150°F(66°C). [']Listed and Certified only by cULus. 14) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (5)Not available for HB escutcheons. Inlet Protrusion Elevated Above Inside R« bust Protn.yon Ele«ted F Above er:de One } I _ F-- --1 i [-- _ =.OA ___ -r,ll�o,1:::: _^g Syelem Tee `—_ 1‘--*eh.. ip et«n r« ■■ M� 'A'Dkeees.n 2 1/2•[63.5mm] t'NPT Adjustment Range Da.Mob Cai'ILp // 2 t/e'Ma. 1•NPf -t/2'[-tz.7mm]] E«u!n«n obsmm] •A•n.,t Ren [.in Cm] +1/2'(+tx.7mm] Ad -6 Renge Mob in CNllry IIII -1/4' -6.35mm] t/z•[t z.7mm] +1 1/0 [+31.75rnm] ,43/..ob. 1 l/2•[3e.t0mm] I -- Eeootn«n la]. [42.47mm] 'I�I total Aeluetmenl LClling 1'[25.4 s«Intl«Can 1r i c..on93 r 1 1/4•[31.75mm] Escutcheon total rnn Escutcheon ---.. I 1/4•[6.35mm] Escueneon Ad]. Ceieng, i2---'L'Tn,-I U Escutcheon Sprinkler Can Nominal Position MIEN-- Adjustment of Escutcheon Nominal Position 1-,/4•[31.7Smm] 1 S/e- e Escutcheon III �II i s/6• Namina gild on 001 [41.3mm] 1/0(6.35mm] Prolruebn [55.eemm) 2 13/64• 1371r048 3•[76.20mm] DIA IOSml-0 Do. Fig. 1 Fig. 2 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides 1/4"(-6mm)to+11/4" position. Escutcheon adjustment provides-1/2"(-12.7mm)to+1/2" (+32mm)"A"dimension adjustment range. (+12.7mm)"A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5314 Model F3 Dry Pendent FP Recessed Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Inlet Protrusion Elevated -rr~T----i•---y-f- ___5p, Above Inside Pipe Rq , , Finishes Sprinkler Escutcheonr_, r_ti ==j Bronze Brass ? == system Tee Chrome Plated Chrome Plated mr.■—• White Polyester(2) White NPT (1)Other finishes and colors are available on special order. Consult factory for details.Cu remainds unfinished. 2 1/2•oia. IIII rY Cup a•Dimension [63.wmm] Only the escutcheon will contain desired finish. Adjustment Range Hole in Ceiling (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or [t6.5mm] 2 19/64'Dta. White. [58.34mm] Standard Temperature Ratings —Nominal Position Sprinkler of Escutcheon Cup Assembly I Sprinkler Max. Classification Temperature Ambient Bulb Color + +rCeiltng' Escutcheon Rating Temp. `— El i ll►_ ceiling Ordinary 135°F (57°C) 100°F (38°C) Orange 1/e[6.35mm] i 1°/Ordinary 155°F (68°C) 150°F (66°C) Red Esa°tans°°Adjustment ntermediate(2) 175°F (79°C) 150°F (66°C) Yellow Escutcheon m Adjustment 3 7/32•oia. [61.76mm] -..- Intermediate 200°F (93°C) 150°F (66°C) Green 1/2•[12.7omm]- - High(1) 286°F(141°C) 225°F(107°C) Blue To1ol Adjustment 153CCO2-C Sprinkler cup and FP Escutcheon fabricated of steel and recommended Fig. 3 for interior applications. Note: Do not install the Model F3 Dry Pendent Recessed Sprinkler in . (l)Listed and Certified Only by LPCB and cULus. ceilings which have positive pressure in space above. [2]Listed and Certified Only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5314 2. Model F3 Dry Pendent Concealed Sprinkler "A"Dim. 372"to 48"(89mm to 1219mm)in 1/4"(6mm)increments net Protrusion Elevated == r�T----t----T" a, (1) (Z) Above Inside Pips HH, CCP Cover Plate ' F•nishes 1 Standard Finishes Special Application Finishes == r'; r.....,_` p`==_' Chrome Plated Bright Brass Plated ,== , system Tee White Black Plated ma Black Paint fl 1-NPT Off White 2 1/r Dia. 'H' Satin Chrome "A"Dimension [63.50mr^j Adjustment Range Hde in C.iling 11'Utilizes the 1/2"cover plate with 3/8"total adjustment. t 3/16" (2)Other finishes and colors are available on special order. [t4.76rnmj 2 19/64"Dia. Consult factory for details. [5e•34mmj Standard Temperature Ratings of Coverplate Nominal Position Sprinkler I Sprinkler Max. Cup Assembly Cover Plate '------ _� A`°.a.°.. Classification Temperature Ambient • ailing.Q. Rating Temp.Rating Temp. L.---...LI�1pi c«linyg� Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) 3/76'14.76 mm] MililV Cove slats Adjustment Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) 3/16•[4.76mm] Intermediate(1) 175°F (79°C) 165°F (74°C) 150°F (66°C) Coverplate Adjustment 3 5/16"Dia. Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) 3/6"[9.53mm] [64.13mm] High(1) 286°F(141°C) 165°F (74°C) 150°F (66°C) Total Adjustment 53sco3-c Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Fig. 4 brass and recommended for interior applications. Note:Do not install the Model F3 CCP Pendent Concealed Sprinkler in ceilings which have positive pressure in the space above. [')Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5314 Model F3 Dry Horizontal Sidewall Sprinkler "A"Dim. 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments Finishes['] Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. I Bronze Brass(5) Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Rating Temp. White Polyester(41 White Ordinary 135°F (57°C) 100°F (38°C) Orange Lead Plated(2) Ordinary 155°F (68°C) 100°F (38°C) Red Wax Coated(2)(3) Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Wax Over Lead(21(3) Intermediate 200°F (93°C) 150°F (66°C) Green '11 Other finishes and colors are available on special order. High 286°F(141°C) 225°F(107°C) Blue Consult factory for details. Sprinkler can and escutcheon fabricated of brass for better weather - (2) 155°F(68°C)to 200°F(93°C)rating only. resistance in exterior applications. (3)212°F(100°C)brown wax may be used on 286°F(141°C)sprinklers when maximum ceiling temperatures do not exceed 150°F(66°C). "]Listed and Certified only by cULus. (4) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (5)Not available for HB escutcheons. 1 /2• 38.10mm - 1"[25.4mm] [ l I Total Adjustment --_----------Ceiling------- Total Adjustment [- r Ceiling i --- - r iI i-r----------------i- 7/2•[12.7mm] T 1 I c T Escutcheon Adjustment •~ 4"[101.60mm] Min. L.-J 4"[101.60mm] Min. 1/2"[12.7mm] 12"[304.80mm] Mon. I ,/4"[3,.75mm] 12•[304.80mm] Max. Escutcheon Adjustment-six Escutcheon Adjustment 2 3/32" r i. 1/4"[6.35mm] System Tee [53.16mmj System Tee I Escutcheon Adjustment 1"NPT i - ," NPT t , I h 1 2 3/32' }r \-1-----.,, \-1' --- ' I [53.18mm] IF I a f�-,J1�{�RIIIIIIIII 2-1J/64" 3_1/2. IIIII I_---'--I -a . . 3 Oia �::::i..._.. .,-- [55.--°' E utcheon II'' D1 O' Escutcheon Dia. hnhIIIllrI f� [76.20mm] 7 `� if--1' 2 1/2" Dia. ``� -7- 1 [63.51mm] 2 1/8" Dia. - • Hole Wall 1-1/4"[31.75mm] Nominal [53.98mm] i I�3•J Protrusion Hole in Wall 1/4"[6.35mm] prmkler Con Sprinkler Can Protrusion .-"A'Dimension Escutcheon P Adjustment(+ Range 1/2"[ 12.7mm] Nominal Position v "A"Dimension ,� of Escutcheon Adjustment Nominal Position - 1/5"[-12.7mm] 15s1204-0 Range - 1/4" [-6.35mm] of Escutcheon rsr/cnr_a + I 1/4 [+31.75mm] Fig. 5 Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides 1/4"(-6mm)to+11/4" position. Escutcheon adjustment provides-1/2"(-12.7mm)to+1/2" (+32mm)"A"dimension adjustment range. (+12.7mm) "A"dimension adjustment range. Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5334 3. Model F3 Horizontal FP Recessed Sidewall Sprinkler "A"Dim. 1372"to 48"(89mm to 1219mm)in 1/4"(6mm)increments (— Ceiling _ Finishes`1' Sprinkler Escutcheon lr 3/32" Escutcheon I [35.7mm] Bronze Brass IT 4• 101.6mm Min. Cup o I *6"€152 4mm�Moe. Chrome Plated Chrome Plated System Tee i;; ' White Polyester(2) White 1'NPT 11'Other finishes and colors are available on special order, }-__ _r- i�_ Consult factory for details. 1 tL_ (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or "� 3 7/32"Dia IIII Q1-- [7/32' , White. i'% 1- I _ I 1 2 1/2' Dia. Sprinkler's can and FP Escutcheon are fabricated of steel and recom- [[63.5mm]] 13; Nominal Position H in wall Of Escutcheon mended for interior applications. 2 19/84'Dia. [58.3mm] Escutcheon Adju[6.35] I stment Standard Temperature Ratings Adjustment Range Escutcheon Adjustment 153F503-E 31/4' 1/4'[6.35] Sprinkler Max. (±6.35] Escutcheon Adjustment Classification Temperature Ambient Bulb Color ., Factory Mutual (FM) . ■" - 8" for Underwriters Laboratories (UL) Rating Temp. Fig. 7 Ordinary 135°F (57°C) 100°F (38°C) Orange Note: Do not install the Model F3 Dry Horizontal Recessed Sidewall Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Sprinkler in walls which have positive pressure in their side Intermediate 200°F (93°C) 150°F (66°C) Green space. High(1) 286°F(141°C) 225°F(107°C) Blue • Recessed Horizontal Sidewall sprinklers are listed by cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) (')Listed and Certified Only by LPCB or cULus. below ceiling, and FM approved for installation of min. 4" (100mm)-to-max. 12"(306mm). Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5334 Technical Data Ordering Information Orifice Size: 1/2" (15mm) Specify: Thread size: 1" NPT per ANSI B2.1 1. Sprinkler Type (select one): Working Pressure: 175 psi (12 bar) (a) Model F3 Dry Pendent . Nominal K Factor-US/(Metric): 5.6/(80) (b) Model F3 Dry Pendent/HB Product Description (c) Model F3 Dry Recessed Pendent Reliable Model F3 Dry Sprinklers are standard response (d) Model F3 Dry Concealed Pendent sprinklers utilizing a durable 5mm frangible glass bulb. (e) Model F3 Dry Horizontal sidewall Model F3 Dry Sprinklers are intended for use in dry and pre- (f) Model F3 Dry Horizontal sidewall/HB action systems and in areas subjected to freezing tempera- (g) Model F3 Dry Recessed Horizontal Sidewall tures, such as freezers and unheated portions inside and 2. Sprinkler Temperature Rating. outside buildings. 3. Sprinkler Finish. Environments wherein dry sprinklers are employed can 4. Cover Plate/FP Escutcheon Finish. be corrosive. For this reason, Model F3 Sprinklers have a 5. Length: "A" Dimension(face of tee to face of ceiling or special wax fillet placed in the gap between the cup that wall) in 1/4" (6.4mm) increments. supports the bulb and the wrenching boss.This wax will not 6. Model F3 Dry Pendent (a) is available without sprin- interfere with the operation of the sprinkler, and it prevents kler can and escutcheon. contaminents from entering the internal portion of the drop Note: nipple.The wax must not be removed. 1. The "A" dimension is based on a nominally gauged Operation pipe thread "make-up" of .600" (15mm) per ANSI The glass bulb consists of an accurately controlled amount B2.1 [7 '/2 threads approximately]. of special fluid hermetically sealed inside a precisely manu 2. All platings and paintings are decorative and intend- factured glass capsule. When the temperature increases ed for interior use. sufficiently due to a fire, the bulb shatters allowing operat- 3. Acceptable appearance in conditions such as park- - ing parts to clear the waterway. This enables the inlet seal ing garages is generally provided with bronze sprin- to release air or water and subsequently, cause water flow kler, brass cup and escutcheon for the Model F3 Pen- over the deflector in a uniform spray pattern, controlling or dent only. ' extinguishing the fire. 4. General Installation Instructions Maintenance Model F3 dry sprinklers must be installed only in stan- The Model F3 Dry Sprinklers should be inspected quar- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) terly and the sprinkler system maintained in accordance pipe tees in the horizontal position,even at branch line ends. with NFPA 25. Do not remove the factory applied thermally They should not be installed into elbows or pipe couplings sensitive wax fillet between the bulb supporting cup and the located on drop nipples to the sprinklers.For these and other wrenching boss. Do not replace this wax with a substitute fittings including CPVC,the dry sprinkler should be installed substance.An Alternate substance may interfere with proper into a fitting to allow protrusion into the fitting in accordance operation of the sprinkler. Do not clean sprinklers with soap with the diagrams. The "A" dimension of the dry sprinkler, and water, ammonia or any other cleaning fluids. Remove which extends into the freezers or a freezing zone from wet dust by using a soft brush or gently vacuuming. Remove pipe systems,should be selected to provide,as a minimum, any sprinkler which has been painted(other than factory ap- the specified lengths in inches shown in Fig.8. plied) or damaged in any way. A stock of spare sprinklers Caution; should be maintained to allow quick replacement of darn- Do not install Model F3 Dry sprinklers into CPVC adapter aged or operated sprinklers. Prior to installation, sprinklers fittings or tees that have an internal obstruction. This will should be maintained in the original cartons and packaging damage the sprinkler and/or the fitting. Refer to Fig. 9 until used to minimize the potential for damage to sprinklers During installation, the following steps must be followed: that would cause improper operation or non-operation. 1. Cut the specified size hole (see illustrations) for the sprinkler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push-on /thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3 Sprinklers is not recom- mended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F3 Concealed and Recessed Installation Instructions • The Model G3 R/C Wrench (Fig. 10) is designed to locate on the wrenching pads of the Recessed sprin- kler while centering in the cup. A standard 1/2" drive ratchet may be used to drive this wrench. Figures 11 and 12 show sequentially the insertion of the wrench. First, the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 12). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector with the wrench. • Model G3 Wrench (Fig. 13) is used for installation of Pendent and Horizontal sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 5. • RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER • WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT AMBIENT TEMPERATURE r` , OERCANSI IRON 16.3 (CLASS 15 )FITTING TEMPERATURE --- r - I�'--- PER ANSI 16.4 (CLASS 125) ONLY, OF PROTECTED 40T/4'C I 50'F/10'C I 60T/16T ' 1 AREA.AT THE -h-- -J—--4—- EXPOSED MINIMUM BARREL LENGTH•• !• ,I , li DISCHARGE END (FACE OF TEE TO TOP OF CEILING In 'I OF THE SPRINKLER ( ) Iw=== ,Ls,1 17--L J == IN. (MM) IN. (MM) IN. (MM) 1 L IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40'F (4'C) 0 0 0 =----=.---- CAUSES CONDENSATION ON THE EXPOSED DRY 30'F (-1'C) 0 0 0 SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION. FOAM INSULATING TAPE OR EQUIVALENT. 20'F (-TC) 4 (101) 0 0 10T (-1TC) 8 (203) 1 (25.1) 0 OT (-16'C) 12 (305) 3 (75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE -10'F (-23'C) 14 (356) 4 (101) 1 (25.1) EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED -20'F (-29'C) 14 (356) 6 (152) 3 (75) LENGTH AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH -30T (-34'C) 16 (406) 8 (203) 4 (101) COULD INHIBIT OPERATION OR CAUSE -40T (-40'C) 18 (457) 8 (203) 4 (101) RECOMMENDED PMETHODS.SEE BELOW FOR CLEARANCE -50-F (-ACC) 20 (508) 10 (254) 6 (152) DIMENSION HOLE 1111. -60T (-5rC) 20 (508) 10 (254) 6 (152) • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE /' �/ I ���/ END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES ' LISTED. USE THE NEXT COOLER TEMPERATURE. __ ••THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. ` I1 ESCUTCHEON NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH CEILING 1I�O�I� WIND VELOCITIES IN THE PROTECTED AREA. I�'IU1,/ (PROTECTED AREA) 3" DIA. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE rt 1-, rt II � u I s� ---tOr--i 'r--�{ - i r----inr--," -, -r--1 n- v.0 -2.--—iii I-'-t-i-IMF--` - I- - - ---ii-iii--IL' i n un I ""' I I --= I r ti. L J iM MN (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO 04003910 (SEE ABOVE) (RECOMMENDED) t / / , fAIPSMIACIIVAIPArdrAii 1 121121011151IIIII7 PArAPINIAPIVAIAIrAll 01/4121/4151/4/2 ' MI CLEARANCE HOLE INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING //////// I//////� '//////// IM IMII12112121/26 _- _- -- ■■ (PROTECTED AREA) `I�u�I+ IN COLD IAREAR (PROTECTED AREA) I IVII DRY COLD SPRIAREA NKLER hj Fig. 8 6. *CAUTION* • DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION II4 F i i1I, - _______l C FEMALE O � FEMALE �'PIPE / PIPE l �l THREAD '� THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE RELIABLE MANUFACTURES A FULL-LINE OF MODEL F3-PL, MODEL F3QR-PL, AND MODEL DH56 HSW-PL DRY SPRINKLERS THAT HAVE A SHORTER INLET FOR THESE APPLICATIONS. SHORTER LONGER IIII INLET INLET MALE MALE min" PIPE PIPE THREAD THREAD MODEL F3-PL, STANDARD MODEL F3QR-PL OR MODEL F3, MODEL DH56 HSW-PL MODEL F3QR OR DRY SPRINKLER MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fg08 Fig. 9 7. • • P S , /:. Fig. 10-G3 R/C Wrench Fig. 11 -G3 R/C Wrench Fig. 12-G3 R/C Wrench 4 Fig. 13-G3 Wrench The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co.,Inc. Recycled (800)431 1588 Sales Offices Paper (800)848 2051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 02/11 P/N 9999970146