Report LENNOX)
RECEIVED
JAN 2 6 2015
• Product Submittal CITYOFTIGARD
Project Information BUILDING DIVISION
Project Name: Battig
Project Number: 3000469017
Project Location: CLACKAMAS, OR 97015, US
Project Altitude: 1000
v 2C/ - 0 a
£s0 d Piro» s
Customer Information 300 •
Company Name: Arjae Sheet Metal Co Inc
Company Address: 8545 SE McLoughlin Blvd
Company Location: Milwaukie, OR 97222
Contact:
Phone: 503-231-7717
Engineering Information
Company Name:
Company Address:
Company Location:
Contact:
Phone:
We are pleased to provide the attached project submittal. If you have any questions or need additional
information,please feel free to call our office.
Project: 3000469017 Battig Last Changed:DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 1 of 8 Phone:503-231-7717
Lennox Industries Inc. - Product Submittal
Table of Contents
System ID Qty Model Description
4-TON GAS/ELECTRIC 1 KGA048S4D PKGGE/4 TON/150KB/460-3
•
Project: 3000469017 Battig Last Changed:DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 2 of 8 Phone:503-231-7717
Lennox Industries Inc. - Product Submittal
System ID: 4-TON GAS/ELECTRIC
Package Model: KGA048S4D Description: PKGGE/4 TON/150KB/460-3
'HEATING PERFORMANCE
Unit Type Packaged Gas
Ype Electric Gas Supply Connection 0.50 (in.)
H/E LowInput 113000 (Btuh) H/E Heat Rise 69.4 (°F)
H/E LowOutput 90000 (Btuh) AFUE/ThermalEff 80
H/E HighInput 150000 (Btuh) Number of Heating Stages 2
H/E HighOutput 120000 (Btuh) Gas Supply Pressure 7 (in.WC)
System HeatOutput 120000 (Btuh)
COOLING PERFORMANCE
Refrigerant R-410A Number Compressors 1
ARI EER 11.0 Number of Cooling Stages 1
ARI SEER 13.0 Condensate Drain Size 1.00 (in.)
ARI Total Power 4400 (W) Cooling OutdoorDB 95.0 (°F)
ARI GrossTotalCool 50000 (Btuh) Cooling CondenserDB 95.0 (°F)
ARI NetTotalCool 48000 (Btuh) Cooling MixedDB 80.0 (°F)
Coil GrossTotalCool 50591 (Btuh) Cooling MixedWB 67.0 (°F)
Unit NetTotalCool 50591 (Btuh) Coil DischargeDB 57.9 (°F)
Coil GrossSensCool 40243 (Btuh) Coil DischargeWB 57.6 (°F)
Unit NetSensCool 40243 (Btuh) Unit DischargeDB 57.9 (°F)
Tube/Fin Refrigerant Charge 8 LBS. 10 OZ. Unit DischargeWB 57.6 (°F)
Coil MoistureRemoval 9.8 (lb/hr)
System MoistRemoval 9.8 (lb/hr)
SUPPLY FAN PERFORMANCE
Supply AirFlow 1789 (cfm) TotalStaticPress 0.59 (in.WC)
ExtStaticPress Supply 0.50 (in.WC) Wet Coil Static Press 0.05 (in.WC)
- SupplyFan NomPower 0.50 (hp) Gas WE Static Press 0.04 (in.WC)
Supply Fan Type CAV Direct Drive Air Filter Qty 4
SupplyDrive Speed HIGH Air Filter Length 16.0 (in.)
Air Filter Width 20.0 (in.)
Air Filter Thickness 2.0 (in.)
ELECTRICAL
Voltage 460V 3Ph SupplyFan FLA 1.5 (amp)
Frequency 60 (Hz) CondensingUnit FLA 1.1 (amp)
System MCA 11.0 (amp) CondenserFan Power 250 (W)
System MOCP 15 (amp)
Compressors RLA 6.2 (amp)
Cooling FLA Total 8.8 (amp)
Unit Oper Range-Nom Voltage +/- 10%
DIMENSIONS
Cabinet Width 47.0 (in.) Downflow Supply Length 18.0 (in.)
Cabinet Length 83.3 (in.) Downflow Supply Width 20.0 (in.)
Cabinet Height 36.4 (in.) Downflow Return Length 11.0 (in.)
Total Weight 590 (lb) Downflow Return Width 29.0 (in.)
SOUND
Outdoor Sound Rating 75 (db)
Project: 3000469017 Battig Last Changed: DAN A. GIVENS
Quote: 4000557656 Battig Prepared On: 2015-01-14
Page 3 of 8 Phone: 503-231-7717
Lennox Industries Inc. - Product Submittal
System ID:4-TON GAS/ELECTRIC
Package Model:KGA048S4D Description:PKGGE/4 TON/150KB/460-3
SYSTEM FEATURES
Durable Outdoor Enamel Paint Finish See Limited Warranty Certificate included with unit for details
Scroll Compressor AGA-CGA Certified
High Capacity Driers Redundant Comb.Gas Control Valve
Separate Compressor and Controls Compartment Electronic Flame Sensor
Limited compressor warranty of 5 years Direct Spark Ignition
Limited warranty on all other components of 1 year
INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED
CONSTANT AIR VOLUME DIRECT DRIVE
2 IN MERV4 FILTER
INCLUDED SYSTEM OPTIONS - FIELD INSTALLED
53W34 1 C1DAMP11A-1 MANUAL OAD W/HOOD
•
Project: 3000469017 Battig Last Changed:DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 4 of 8 Phone:503-231-7717
I
Lennox Industries Inc. - Product Submittal
System ID: 4-TON GAS/ELECTRIC
Package Model: KGA048S4D Description: PKGGE/4 TON/150KB/460-3
• DIMENSIONS-INCHES(MM)
CORNER WEIGHTS CENTER OF GRAVITY
Model AA BB CC DD EE FF
No.
Base Max. Base Max. Base Max. Base Max. Base Max. Base Max.
lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm in. min in. mm
024 92 42 113 52 112 51 128 58 180 82 207 94 148 67 183 83 38-1/2 978 40 1016 18 457 18 457
030 92 42 114 52 112 51 129 58 180 82 207 94 149 68 183 83 36-1/2 978 40 1016 18 457 18 457
036 92 42 114 52 112 51 129 59 181 82 208 94 149 68 184 83 38-1/2 978 40 1016 18 457 18 457
048 99 45 123 56 120 55 139 63 193 88 223 102 159 72 197 90 38-1/2 978 40 1016 18 457 18 457
060 104 47 128 58 126 57 145 66 203 92 233 106 167 76 206 94 38-1/2 978 40 1016 18 457 18 457
072 121 55 143 65 147 67 162 74 237 108 261 119 195 89 231 105 38-1/2 978 40 1016 18 457 18 457
090 168 76 195 88 183 83 212 96 227 103 263 119 203 95 241 109_ 47 1194 47 1194 21 533 21 533
Base Unlit-The unit with Banda d heal exchanger NO OPTIONS.
Max.Unit-The unit with ALL OPTIONS Installed.(High Input Heat Exchanger.Economizer.etc.)
1438 e m 16-1/4 18
11 (413)(457)
A� (279) 1 I BB
7(178) BOTTOM 5(102)
tIR ARRN
BOTTOM (508) CENTER �(�� SfrfVf
(737) SUPPLY/ GRAVITY \m % //
47(1192)
OPENING
I `I,
FF
BASE I 25.314(654)
024 llru 072
_ � r 38-314(984)090�
f
6���0 (—+—)
1(241)
DO {—� CC
2612 BOTTOM —EE �{
(673) CONDENSATE
OUTLET BOTTOM POWER ENTRY
3X8(76%203)
TOP VIEW(Base)
4s 83-1/4(2115)024 thru 072 -1
�—(1143) 96-1/4(244 5)090 1
og is
III
I
D III
3 a
ELECTRIC
AL
•
8 o FLUE/VENT INLET
o e c
ms \ /GAS II.
CONDENSATE INLET
Em riri i OUTLET MBB •
�t A
(EITHER SIDE) ±1.1—
11 ) d I" i 5-1/2 15 I I±1
IOC = CI ooII"7(l 31/2(89) }0, (140) (381), 1(25)
-f— r—� i 001
a7(1192) 1 (6 3) 27 J
BASE I LIFTING HOLES (673)����-111 (686) ^1
(For rigging) 85-1/4(2165)024 thru072 BASE
END VIEW sa•va(2496)090 BASE
SIDE VIEW
11
�/11n�+163r8� _(279)_ �+--
(485) (467) 1 2(51)
II1IIII
ill I III t 29
2 1
'I I IIII I 1 37)
II II III (508). - C -L
�O \l I /_c. ..)17
FORKLIFT SLOTS 5.1/2 HORIZONTAL HORIZONTAL 5.1/2 Back• (FBlow'er End)and (140) SO ENINGR ROPEN GR (140)
(Without Economizer)
BACK VIEW
Project: 3000469017 Battig Last Changed:DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 5 of 8 Phone:503-231-7717
Lennox Industries Inc. - Product Submittal
System ID:4-TON GAS/ELECTRIC
Package Model: KGA048S4D Description: PKGGE/4 TON/I 50KB/460-3
OUTDOOR AIR DAMPER HOOD DETAIL FOR OPTIONAL MANUAL OR MOTORIZED OUTDOOR AIR DAMPERS
(Downtlow or Horizontal Applications)
10.11E
i "l 11 K 35
;267r
1111 I 1111 II HCOD DP11ONAL (889)� 4r
11 AIR DAMPERS ET25
H1 I ARID PAPANEL 13-L2
OUTDOOR AIR
L1 MP8t
OUTDOOR AIR MIIII aloo111111 '
DAMPER HOOD
fit"e"ecF SIDE VIEW 35
14
1889)
18-1/2
141 9) -10.1;)
Project: 3000469017 Battig Last Changed:DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 6 of 8 Phone:503-231-7717
,Lennox Industries Inc. - Product Submittal
System ID: 4-TON GAS/ELECTRIC
Package Model: KGA048S4D Description: PKGGE/4 TON/150KB/460-3
• UNIT CLEARANCES-INCHES(MM)
OUTDOOR AR J/J, B —NW
MOOD
D —�
t
1A
1
1 Unit Clearance A B C D Top
in. mm in. mm in. mm in. mm Clearance
Service Clearance 48 1219 36 914 36 914 36 914
Clearance to Combustibles 36 914 1 25 1 25 1 25 Unobstructed
Minimum Operation Clearance 36 914 36 914 36 914 36 914
NOTE-Entire perimeter of unit base requires support when elevated above the mounting surface.
1 Service Clearance-Required for removal of serviceable parts.
Clearance to Combustibles-Required clearance to combustible material.
Minimum Operation Clearance-Required dearance for proper unit operation.
Project: 3000469017 Battig Last Changed: DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 7 of 8 Phone:503-231-7717
Lennox Industries Inc. - Product Submittal
•
MISCELLANEOUS MATERIALS
20W05 CIACURB30A GCS/CHA/CHP16/20-511/653 TO T
Project: 3000469017 Battig Last Changed:DAN A.GIVENS
Quote: 4000557656 Battig Prepared On:2015-01-14
Page 8 of 8 Phone:503-231-7717
•
•
1msT>ato>s TTLERact4 PER ARM rlah>mn
REVISIONS
Attn: Tag: 2OWO5 REV. DESCRIPTION DATE APPROVED
Approval: 02 LOWERED CURB HEIGHT FROM 20'TO 1' 3/30/07
41111W
Ts7 w,a 1
n�2aF-
1 RETURN AIR
33 1 10"
22 15/113'
33 �.�
L i '�\ SUPPLY AIR
....„,, .....:
I L EXISTING CURB LAYOUT ��
ene
301 ��
nr /
D 11
2117• 20 1/193" 2111•
2 114" III
22�18• RETURN 2151W
SUPPLY
3017'
■
- 78 3/4"—- —-
—411
e1/• '•I + I I.. 7 .1 r_r
IT
- 701/2" 1 5 7
CD NOW HUmG. Ern1418 UIe Now UN Tonne,`,LN0 Rob.
.m Pop Possum Mop
I-2005-'.Ofi0 GCSICHA/CIO 11111MS ENNOX TCLASS A 800 2 �O,s 0.014 0.016
GCS2XCIVA.411m0 10 00Th 0022
0025 S05
030 0045
_ or 008
AMP,.AL> h>n ,•120W05
-CURB SHOWN IS CDI STANDARD CONFIGURATION T1 164.68 .�"%
Noun CDI RESERVES THE RIGHT TO CHANGE LAYOUT �Fr� QUOTE#:
1.15'ADDED TO OLD CURB 00 WITHOUT NOTIFICATION.IF CURB IS NEEDED IN A •45(33 Friday,E>hrw708.,'RORI Er/AM
2 MATERIAL 16 pp.GALVANIZED STEEL EXISTRJG SUMS •{!;k® 1TSa0 TYLER ST MY ^"'s' 1sSS
3.GASKET PROVIDED IMTH CURB DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED VEREAxv CHANGES RETURN OPENINGy e.^°' ELK RIVER. 55331 20VV05-1-2005-2060 L
4 INSULATION'.I.1 1/2 LB DENSITY PRIOR TO PLACING AN ORDER. Nr..m'm =�� CDI 17931341.7741 T<P.
,F•X SACK If DRAWING IS ON AS IS ire 1793134 scau 1251 1 r 3
C
•
W
J
EXISTING 2x6 SUB-PURLINS
AT 2'-0"O.C.,TYPICAL (E)PURLIN (E)PURLIN
WII KRJ
SISTER 2x6 TO EXISTING NEW HVAC UNIT TO
2x6 SUB-PURLIN BEAR ON NEW OR
EXISTING FRAMING
ON ALL SIDES
(WEIGHT=590#)
NEW 4x8 WITH SIMPSON
(E)PURLIN cc (E)PURLIN HANGERS PER SECTION,
Ui CUT BACK EXISTING
SUB-PURLINS AND
5 SECURE WITH SIMPSON
'LUS26'FACE MOUNT
5 HANGER
J
C)1 ENLARGED FRAMING PLAN
S-2 1/4"= 1-0"
DR BATTIG DENTAL HVAC 20140760 JAN,2015
PRO, DATE
PPER BOONES FERRY RD#300 ANK KMK
L M K 15800 U, OR 97224 DRAWN ""�°
ENGINEERING + 15800 UENLARGED FRAMING PLAN S-2
3933 SW Kelly Avenue Portland,Oregon 97239 I te1:503.222.4453 I fax:503.248.9263 I vrww.vlmk.com
SkEET
as
WNW
HVAC UNIT AND CURB
BY OTHERS
A
a El it izi
IM II- la
> /////A FRAMING PER PLAN,TYPICAL
k \
////\ SIMPSON'HUS48'FACE MOUNT
\\\`\\\ HANGER, TYPICAL
Q N.'
A EXISTING PURLIN BEYOND,TYPICAL
EXISTING GLULAM GIRDER
(19 HVAC SUPPORT DETAIL
-o"
DR BATTIG DENTAL HVAC 20140760 JAN,2015
N
■15800 UPPER BOONES FERRY RD#300 ANK KMK
V L M 15800 UPPER
OR 97224 DNA,V4 ENGINEERING + DESIGN HVAC SUPPORT DETAIL S-3
3933 SW Kelly Avenue Portland,Oregon 97239 I tel.503.222.4453 I fax:503.248.9263 I WNW.vlmk.wm yE „
UNIT CASING
UNIT BASE AND BASE RAIL
SECURE ANCHOR TO UNIT WITH
(4)#10 x 1/2"TEK SCREWS
V SECURE ANCHOR TO CURB
. WITH(4)#10 x 1/2"TEK
.
SCREWS,TYPICAL
min
ism
un
iii WOOD NAILER
16 GAUGE STEEL'CANFAB' ' '
i•n
OR EQUAL ANCHOR,(4) '..'
� UNIT MOUNTING CURB BY UNIT
TOTAL, (1)EACH CORNER lUl
ON LONG SIDES OF UNIT Iii MANUFACTURER(14"HEIGHT)
un
:
un
'un
'••' MINIMUM 2x P.T. LEVEL
GALVANIZED SHEET METAL ism
' ' PLATFORM BY CONTRACTOR
COUNTER FLASHING °m
un
un
�••' EXISTING ROOF SHEATHING,
un
iu'
ROOFING BY OTHERS IUi REMOVE UNDER UNIT AS REQUIRED
IlySECURE CURB TO SUPPORT FRAMING
WITH#14 WOOD SCREWS AT EACH
CORNER AND AT 2'-0"O.C. SUPPORT FRAMING PER PLAN
MAXIMUM SPACING,SCREWS MUST
BE LONG ENOUGH TO PENETRATE
SUPPORT FRAMING 2"MINIMUM
1 HVAC CURB DETAIL- NEW UNIT
S-4 1 1/2"= 1'-0"
II
`� DR BATTIG DENTAL HVAC 20140760 JAN,2015
15800 UPPER BOONES FERRY RD#300 ANK KMK
V L 11/1 K 15800 UPPER
OR 97224 140 CHECKED
ENGINEERING + DESIGN HVAC CURB - NEW UNIT S-4
3933 SW Kelly Avenue Portland,Oregon 97239 I Ie1:503.222.4453 I fax:503.248.9263 I www.vlmk.cam ET MO
UNIT CASING
UNIT BASE AND BASE RAIL
SECURE ANCHOR TO
UNIT WITH(4)#10 x 1/2"
TEK SCREWS
• U SECURE ANCHOR TO CURB
WITH(4)#10 x 1/2"TEK
`j SCREWS,TYPICAL
16 GAUGE STEEL'CANFAB' HVAC UNIT ADAPTER CURB
OR EQUAL ANCHOR, (4)
TOTAL, (1)EACH CORNER
ON LONG SIDES OF UNIT
rk
SECURE HVAC UNIT ADAPTER CURB
TO EXISTING CURB WITH MINIMUM IF/
(4)#10 x 1/2"TEK SCREWS EACH
CORNER AND AT 12"O.C.AT SIDES,
ism
TYPICAL ism
Ism
!um UNIT
ii MOUNTING CURB
mei
(APPROX 14"HEIGHT)
iul
EXISTING ROOF SHEATHING /
nn
EXISTING ROOFING
/
ih I•�
VERIFY THAT EXISTING CURB IS FASTENED TO v
EXISTING SUPPORT FRAMING WITH A#14 SCREW EXISTING FRAMING
MINIMUM AT EACH CORNER AND AT 24"O.C., PER PLAN
EACH SIDE. IF ANCHORAGE DOES NOT EXIST,
PROVIDE SIMPSON'LTP4'OR'A35'CLIPS AT
EACH CORNER AND AT 48"O.C. EACH SIDE
FROM THE INSIDE OF THE CURB TO THE
EXISTING ROOF FRAMING
HVAC CURB DETAIL- REPLACED UNIT
1 1/2"= 1'-0"
VV DR BATTIG DENTAL HVAC 20140760 JAN,"2015
15800 UPPER BOONES FERRY RD#300 ANK KMK
L M K 15800 U, OR 97224 °"""" °"""`°
ENGINEERING + DESIGN HVAC CURB - REPLACED UNIT S-5
SW Kelly Avenue Portland,Oregon 9/749 I le1:5032224453 I fax 503.248.9263 I www.1mk.00m s<< �,
RECEIVED
JAN 2 6 2015
CITY OF TIGARD
BUILDING DIVISION
DR. BATTIG DENTAL
HVAC ADDITION
15800 SW Upper Boones Ferry Road, Suite 300
Tigard, OR 97224
STRUCTURAL CALCULATIONS
VLMK Project Number: 20140760
Norwest Contractors
4820 SW Scholls Ferry Road
Portland, OR 97225
� RuCTof?
,cskE� PROF£ss<
pi�jf"G NfF,Q /,*
1g/
•�'EGON o
li
<<\ t 3 Z0 P�
IlkiViZ 0,
Q� 1-22-15
EXPIRES: 6-30-20 15
•
V VLMK
Prepared By: Amy Kordosky, E.I.T.
1/22/15
ENGINEERING + DESIGN
1
Structural Calculations:Dr.Battig Dental HVAC Addition DC 1
Dr Battig Dental
HVAC Addition
15800 Upper Boones Ferry Rd Suite 300
Tigard, OR 97224
VLMK JOB NO. 20140760
STRUCTURAL CALCULATIONS FOR BUILDING PERMIT
TABLE OF CONTENTS
Design Outline and Criteria DC-1 thru DC-2
Structural Details S-1 thru S-5
Structural Calculations C-1 thru C-10
Reference Documents R-1 thru R-2
DESCRIPTION OF STRUCTURAL SYSTEM
The 'Dr. Battig Dental HVAC Addition' project consists of the addition of one HVAC unit and the replacement of one
HVAC unit at the above noted building. The units have been designed to resist wind and seismic loads.
***LIMITATIONS***
VLMK Engineering + Design was retained in a limited capacity for this project. The design is based upon information
provided by the client, who is solely responsible for the accuracy of the information. No responsibility and/or liability is
assumed by, nor is any to be assigned to, VLMK Engineering + Design for items beyond that shown in this Structural
Calculation Package.
3933 SW Kelly Avenue Portland,OR 97239 te1:5O3.222.4453 VLMK.COM G4tcad2O14\2O14O16U alculations\2O14O76O DC.docx
Structural Calculations:Dr.Bottig Dental HVAC Addition DC-2
CODES
2014 Oregon Structural Specialty Code (Based on the 2012 International Building Code)
DESIGN LOADS
Live Loads
Roof Snow Load
Flat Roof Snow Load, Pf 25 psf
Dead Loads
Roof(Panelized)
Roofing (new and future) 4.0 psf
Insulation 1 .5 psf
Sheathing (5/8" plywood) 1.8 psf
Sub-purlins (2x6 at 24") 1.2 psf
Joists 3.0 psf
Girders 1.0 psf
Mechanical and Electrical 1.0 psf
Miscellaneous 1.5 psf
Total Roof Load 15.0 psf
Weight of HVAC Unit 590 lb
•
Weight of curb 165 lb
Wind
Ultimate Design Wind Speed, Vii, 120 mph
Risk Category II
Wind Exposure B
Internal Pressure Coefficient GOD, = +/-0.18
Seismic
Seismic Importance Factor, le 1 .0
Risk Category II
Mapped Spectral Response Accelerations S5 = 0.967
S, = 0.419
Site Class D
Spectral Response Coefficients Sds = 0.717
Sd1 = 0.442
Seismic Design Category D
Analysis Procedure Used Nonstructural Components
Component Anchorage Factors ap Rp 1p f2o
HVAC Equip 2.5 6.0 1 .0 1 .0
3933 SW Kelly Avenue Portland,OR 97239 te1:503.222.4453 VLMK.COM G:\ cod2014\20140164alculations\20140 760 DC.docz
\t,711v.„... , ot, r ► i 11
•
cu /,' 1, i • • ‘ 1
- - ./ -,. - _ It
AREA OF WORK
• f Ups,°er,Booynes Ferry Rd #3(,CP =. ... I' \ '
.,,. r -.
., ", ...
. i_
,, i .
. , 44, 4., . ..
i IL
■ OM 7 • 'A
•
■
p _ .
el.,1DR. BATTIG DENTAL
w , �� , E s-1
s
. , . , „ ,
(2) NEW 4-TON HVAC UNITS, (1)TO
REPLACE EXISTING UNIT(TOP) .
AND(1)ADDITION (BOTTOM),AND 'eta.-. �.�•�- -, .... f,
BE SUPPORTED ON ALL SIDES -, . : j'
WITH NEW OR EXISTING FRAMING
•
(WT=590 LBS). SEE 1/S-2 FOR e
ENLARGED FRAMING. °r a
®■
• r.e f
Li i1 -'-
•
. ; .+
44
1/4., CO 2 AREA OF WORK
�- , S-1
.. ,.
r
DR BATTIG DENTAL HVAC 20140760 1/2015
MIT
15800 UPPER BOONES FERRY RD#300 ANK KMK
V L NI K TIGARD, OR 97224
ENGINEERING + DESIGN AREA OF WORK S-1
3933 SW Kelly Avenue Portland,Oregon 97239 I bI:503.222.4453 I fax:503.248.9263 I www.Nmk.00m aEnw
• 1/22/2015 Design Maps Summary Report
��GS Design Maps Summary Report C"
-
- User-Specified Input
Report Title Dr Battig Dental HVAC
Thu January 22, 2015 17:12:49 UTC
- Building Code Reference Document 2012 International Building Code
(which utilizes USGS hazard data available In 2008)
Site Coordinates 45.4054°N, 122.7468°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category I/II/III
-SIR}' t r",i1, •' s• I jai _, ot#tr ►1'I;o - `ftttt or iUkI,-':1..I
S1 ' { ° '. tI +.J ,,•11 "z ` td .
"°rNft�i;1 �' I,f� ,�- F� ,, :, Lake OswOafbfi.Cti ,, .,
.:'!''•.:!:ail I I. 'ly` •-• .• ..E '1:F.:11:,',}�, it .'+ 4 �' r: �•
r I 1!114 i;'' �., t i :1..,' {I� 4 46: V 7 til, C I S c k t:
y U
�,." . '1 it.,1. i f• r, .T�j I j i, 7•i :I ...._ .,, . 7 C •,I ...
,. ..p: ;... sal••, ,x , • : ..•• � ' �a,,' pJ
ti i4.1 '; ;4,- 4;-i. l Li {.. n .0,;,-, .. < 6-.R T'1 14 titi. �' ° 'I
,:;;,•:,..,:: ; , l uI F alatin 1St iti'•
""I, •ii ti. Iqi. ,i I 'a•ii ! 'i I ii. >': I^•:f'` ' 1{l i;y
..• 8, . 1�,As ,w Q ii�,xn,E.'�:t' A r' I C %l :;01..,C*;
.• P-la :,N;, :q..;: ,l,2, 'd:.•`..��, •y 'ti„`�\
59 Itit� F� 1e1 {. ' .g(� y,P14 r` ,4 (I rtliµ
ail .'h, t -:N)! N •>,4r •�:a:,w.;:l.tG�i;,, !'t• ,t i i` j'iii 4y I•;.'
ll� t
• � U_ { :I. i a.,;Ithll R--F_III:H'IIM�"�1� �Z�,is t 1,00,4! ® QIIISY
USGS-Provided Output
55 = 0.967 g SMS = 1.076 g Sos = 0.717 g
S1 = 0.419 g SP,1 = 0.663 g Sol = 0.442 g
For information on how the SS and Si values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the"2009 NEHRP" building code reference document,
MCER Response Spectrum Design Response Spectrum
1.10 0.72
0.95
0.64
O.QC
0.56
0,77
0.48
fT 0,66 01
to 0.55 I D.40
0.44
0'32
0.33 0.24
0.22 0.16
0.11 0.08
0,00 0.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.50 1.80 2.00
Period, T(sec) Period, T(sec)
_
Although this information Is a product of the U.S.Geological Survey,we provide no warranty,expressed or implied,as to the
httpJ/ohp4-earthquake.cr,usgs.govldes i gnm apslus/s um mary.php?tem pl ate=minimal&1 ati tude=45.405481ongi lode=-122.7468&s i lecl ass=38ri skcategory=0&edit-.. 1/2
I
• VV L M K P,u;e,t: biz.fle .a.Airfet,u 2.a44076o Hy A►.1 K Lille: (yano Sheet it: G_Z
ENGINEERING•DESIGN
I ice. pri: s . . i ' . . .
2.x , •*0 AV12h i . .10 : .? •
•
. . e7E*t y. ,. Vb,`6s '. x�y2
! •: . . I . . :; ce•. . . 7 .. • . ... .c. .itr'.A
, .: . . ( -
B ' &• . �4!{�6045, pt=4it,
G/%)4. 4$0er. . ( 0 .. ..
J?- f.'T.. 4)2x6 .: ;Suppei r.. IT. .AIy1TJ... A'L T. . , . .
•
9acfG PWR4...Ini:.....; , • : .
: I
r
. . ;, . . (1. pf)(ii). �2 ?pfd - r
I
.. . i . ;. . - • ... •'.1 . . .:. I. 1 I ; 1 i 4LerAq-;..(0.0'."14 e(y-1
/�J
. ... .: .',..$)ci iti.0.7G_414.).tprOlt6_. 4! , ,.. .E.Cala. , Y.042..)*. L2d11.J.K.::i..t: - .I. 1 ._.....,. ..__,.....f. ...__....4....,....._....._.
H
ry w COND rpoN : i4 24.$ • . .. :: , :
: .
• .. . ... . .: •..... : • • : i....:... :• • • . :• 1 : : : • : : : :: : : IN : i. .: • . • . • i.: . I r: :• } : •:.: . ..• ••4 . . . . . .
. . .: .i. i: ..: .:••••:• ••••••-..: i . ••:. .: • :
. • • : : . [ : : :. f . •. it.A•isiG.: • zoi:•24k k.:A..-1.7t;iga 14
: .. . . t).1.1: . 4. i6 PU gi-w , . .t. . .. .der..To ?►JP !�ftC. 1//1/h:.. :
, I i 1. :..
{ •
• - •• • - - : ! • - • - • i• i::::?.• '4 i",:'%
„ . .. •. i.. I: .. 1 . . .... .... .. . . ,i. . ,, . . i . . , 1 i . .. , . , . :,, ... . .. . , 1„.\-14,,,,:iii„.:(,,Vi .
3933 SW Kelly Avenue Portland,OR 97239 tel: 503.222.4453 fax: 503.248.9263 www.vlmk.corn
C--3
Wood Bea L�p�'�� i File=GMead20t41201407501C7AMIC lfRIAKO7T C6:
m fit lF,.... ENERCALC,INC.i983-2015,auBd&154 19,;Vee8.13.1,19
- Lic.# :KW-06002726 Licensee:VLMK CONSULTING ENGINEERS
Description: 2x6 Sub PurlIn
. CODE REFERENCES .°I
Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10
Load Combination Set:ASCE 7-10
Material Properties
Analysis Method: Allowable Stress Design Fb-Tension 900.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-10 Fb-Compr 900.0 psi Ebend-xx 1,600.0ksi
Fc-Pril 1,350.0 psi Eminbend-xx 580.0ksi
Wood Species : Douglas Fir- Larch Fc-Perp 625.0 psi
Wood Grade :No.2 Fv 180.0 psi
Ft 575.0 psi Density 32.210 pcf
Beam Bracing Beam is Fully Braced against lateral-torsion buckling Repetitive Member Stress Increase
.................
n n} O.05)
D � + )5To
i * 1♦ * i
r1 ranm"791 1.1TF7'1 I,1l it ll 7111'1 1 ;1 1"7 :111.111 l ii
.LllAi,illdlitLh6ii.i,L...1..6t..n.... -,u'.- ..,Lli.d,la,tli.,,..,,,,.w..bt,Id...,.,1...I ...,,,.1.11htlatut.Ld&tiiillittuitali i,.,.;uu..tl..,L1.i i!dli�;li,1Uit •
• •
• •
2-2x6
•
Span=BAR .-... !
Applied Loads Service loads entered.Load Factors will be applied for calculations.
Uniform Load: 0=0.030, S=0.050, Tributary Width=1.0 f
Point Load: D=0.1890 k ca 3.910 f1
- Point Load: D=0.480 k A 3.910 ft < 5.0,V, OKAY
SIGN SUMMARY .: -,:::::
D -.-__- Desi"n N.G.
Maximum Bending Stress Ratio a 1.033 1 Maximum Shear Stress Ratio = 0.275 : 1
Section used for this span -2x6 Section used for this span 2-2x6
fb:Actual : 1,250.71 psi fv:Actual = 57.00 psi
FB:Allowable a 1,210.95 psi Fv:Allowable = 207.00 psi
Load Combination +D+H Load Combination +0+S+-F1
Location of maximum on span = 3.912ft Location of maximum on span = 0.000 ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward Transient Deflection 0.000 in Ratio= 0<360
Max Upward Transient Deflection 0.000 in Ratio• 0 <380
Max Downward Total Deflection 0.298 in Ratio= 322
Max Upward Total Deflection 0.000 in Ratio= 0<180
Maximum Forces&Stresses for Load Combinations
Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span# M V Cd C FN C i Cr CM C t CL M fb Pb V fv F'v
+D+H _ 0.00 0.00 0.00 0.00
Length=8.011 1 1.033 0.252 0.90 1.300 1.00 1.15 1.00 1.00 1.00 1.58 1,250.71 1210.95 0.45 40.81 162.00
+O+S+H 1.300 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=8.0 ft 1 1.013 0275 1.15 1.300 1.00 1.15 1.00 1.00 1.00 1.98 1,567.92 1547.33 0.63 57.00 207.00
Overall Maximum Deflections
Load Combination Span Max.'"Dell Location in Span Load Combination Max."+"Defl Location in Span
. +0+541 1 0.2976 4.000 0.0000 0.000
• C- 4
I II Y k4k 6'1.::1 Yi 17Y 1)a1R 41'114itP 44444444'7.td 1 17•f711:1]t ! 4 .
w}�od beam r1,1 I:;l r � 4�"i ' i;""' •iMT '.f}r+ 3 Ifk I f l�,�l'l� pl,rr��1�1 41p �lf�� a 1'i 1; phi i li4A&kF File. GA Aoad2014%201407601C7A4Y0-FT4HAKO TECB•
T �.�.d.� k'• °� Y� (�I i a�l:l.,ll l�t t 1 �� ct +•:��:�";�� 'ENERCAL0,;INC:,1903-2015;BuGd:6.15.1.19,Ver.6.15.1,19
...ii 'El tR,.,{kd�i 71 .9t' t•1 L
Lic.#. KW-06002728 Licensee:VLMK CONSULTING ENGINEERS
Description: 2x6 Sub Purlin
• Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 0.662 0.647
Overall MiNimum 0,462 0.447
+D+H 0.462 0.447
+D+S+H 0.662 0,647
G-5
eta B dm Analysis
If.'. I :41.11,-911,r El i1,11;41:14t MP HIM 4:1141141 I t 1 I.Prf ltiOr I%1.11i:i Pi;i V. File c G:LActid2014120140760107A0C7F1F4HAKO-T.ED3,
''!1‘1101'1.1111•F::!1.111i1r"rtir, ' ' , ''''' ''1'1'''''''''''''"I'I'I'I l' ' ENERC.ALC,INC.11983-2015BulkLi.15.1.19,'Ver.615.1.19•i
. , .
' Lic.1, : KW-06002 7 2 0 Licensee :VLMK CONSULTING ENGINEERS
Description: 4x16 Puffin
Genera,DOR.-:--r rOPO-a LI G'S! ;,];:!: ''':
;!!;::;:111,:,ii;i:!: :■..,:
Elastic Modulus 29,000.0 ksi
Span#1 Span Length = 24.420 ft Area 10.0 lin Moment of Inertia = 100.0 inA4
ofelsto.21
* * Ti IV
Span=24.420 0 2
1
1
1 .
..,..„, ...... .., ,...,:..:.,... .ip;iv 1.,::!9::
APPlied Load":• .4.41!1,.11.:!•-!!:'11::,,Ii„0,-.-,...-4- Service loads entered.Load Factors will be applied for calculations.
Uniform Load: D=0.120, S=0,20 kit Tributary Width=1.0 f
Point Load: D=0.2830 k 0 6.92011
'.
DESIGN SUMMARY ,, ,,•.i.:':!:•!.1'..'
. ... .
Maximum Bending= 24.843 ii-ft Maximum Shear= 1 4.110 ki
Load Combination •+S+H Load Combination -i-D-i-S-0-1
Location of maximum on span 11.966ft Location of maximum on span 0.000 ft
Span#where maximum occurs Span#1 Span#where maximum occurs Span#1
Maximum Deflection
Max Downward Transient Deflection 0.000 in 0
Max Upward Transient Deflection 0.000 in 0
Max Downward Total Deflection 0.929 in 315
Max Upward Total Deflection 0.000 in 0
_
Maximum Forces&Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span# M V Mmax+ Mmax. Ma-Max Mnx MrixlOmega Cb Rm Va Max Vnx Vnx/Omega
Overall MAXimum Envelope
Dsgn.L= 1.95 ft 1 7.42 7.42 4.11
Dsgn.L= 1.95 ft 1 13.62 7.42 13.62 3.48
Dsgn.L= 2.0811 1 18.86 13.62 18.86 2.86
Dsgn.L= 1.95 tl 1 22.25 18.66 22.25 2.20
Dsgn,L= 1.9511 1 24.16 22.25 24.16 1.29
Dsgn.L= 2.0811 1 24.84 24.16 24.84 0.66
Dsgn,L= 1,95 ft 1 24.84 24.23 24.84 0.63
Dsgn.L 2.08 ft 1 24.23 22.24 24.23 1.29
Dsgn.L= 1.95 11 1 22.24 19.10 22.24 1.92
Dsgn.L= 1.95 ft 1 19.10 14.75 19.10 2.54
Dsgn.L= 2.08 ft 1 14.75 8.78 14.75 3.21
Dsgn.L= 1.9511 1 8.78 1.91 8.78 3.83
Dsgn.L= 0.49 ft 1 1.91 1.91 3.99
4-D+H
Dsgn.L= 1.9511 1 3.03 3.03 1.67
Dsgn.L= 1.9511 1 5.60 3.03 5.60 1.43
Dsgn.L= 2.08.11 1 7.83 5.60 7.83 1.20
Dsgn.L= 1.9511 1 9.17 7,83 9.17 0.95
Dsgn.L= 1,9511 1 9.79 9.17 9.79 0.43
Dsgn.L= 2.08 ft 1 9.95 9.79 9.95 0.20
Dsgn.L= 1.95 ft 1 9.94 9.61 9.94 0.29
Dsgn.L= 2.0811 1 9.61 8.76 9.61 0.53
• Dsgn.L= 1.95 fl 1 8.76 7.49 8.76 0.77
Dsgn.L= 1.9511 1 7.49 5.76 7.49 1.00
Dsgn.L= 2.08 fl 1 5.76 3.42 5.76 1.25
Dsgn.L= 1.95 ft 1 3.42 0.74 3.42 1.49
• Dsgn.L= 0.49 ft 1 0.74 0.74 1.55
+D+S+H
Dsgn.L= 1.95 h 1 7.42 7.42 4,11
Dsgn.L= 1.95 ft 1 13.62 7.42 13.62 3.48
Dsgn.L-7- 2.08 ft 1 18.86 13.62 18.86 2.86
Dsgn.L= 1.95 ft 1 22,25 18,86 22.25 2.20
Dsgn.I= 1.95 ft 1 24.16 22.25 24.16 1.29
i
VV L M K prow s?rctiG,gym- lob n: 2,0.ryn�60 BY: AN K vote !//2�g Sheet n: C
CH IN!l RING t O!lION -_._..__.____,..._..._.. .,•=...__.._.__._�_ /
: •: j ; :.I GRLAV rrY. TNALititr6 Okrr. I
• i
nNO
25AK. 5:)g G-LB . .
•...:.... :..: . .
Pte. .. :' , ''fit,► ! wtt*wLL : .
------': �_____-_....- .• . ,,._ _ z(25 p5f)Cl 7. ' ' - ! • •
,1 C: \A1 \ .% t' k•. ,Y`. , 4, ` F . .. . . .
.f .cit W . . ornokr. Mry�A,K= 1 .q.C-14 .r ` .'- GrS�
SU LT:: CL:Z (Z...AVEqV r lb p a1 ` ti... ' ON1'Ml .:. •
: • . . . . .. .1
•
3933 SW Kelly Avenue Portland,OR 97239 tel: 503.222.4453 fox:503.248.9263 www.vlmk.com
A
Cr.'?•
` !'' l l Genera Beam Ana S., l,,s,,.. WW�iviitiiaft± a mre 1rk ok!..tr Fftibi . ildffri File.G:Vced2ot412t11407901C7A4YC F41AKQTE ,'
I.. i , ,:ENERCALC,•INC.19032015,Bdid.6,i5.1.19,Vei6.16.1,19+
Lic.#:KW-06002728 Licensee:VLMK CONSULTING ENGINEERS
Description: 25 112 x 5 1/8 GLB Existing
• Genoral Beam Properties
Elastic Modulus 29,000.0 ksi
Span#1 Span Length = 6.0 ft Area= 10.0 inA2 Moment of Inertia = 100.0 in04
Span#2 Span Length = 40.0 ft Area= 10.0 inA2 Moment of Inertia = 100.0 in04
Span#3 Span Length = 6.0 ft Area= 10.0 inA2 Moment of Inertia = 100.0 in"4
0(9304)5(0 0( 0(0 304)0 508) 0)03041$(0500) F
• 'i ♦ ♦ ♦ V V
stun e.0N X Span=40.ON Span-6.0N
i4
•
Applied Loads Service loads entered.Load Factors will be applied for calculations.
Load for Span Number 1
Uniform Load: D=0.3040, S=0.5060 k/ft, Tributary Width=1.0 f
Load for Span Number 2
Uniform Load: D=0.3040, S=0.5060 k/ft, Tributary Width=1.0 f
Load for Span Number 3
Uniform Load: D=0.3040, S=0.5060 k/ft, Tributary Width=1.0 f
DESIGN SUMMARY
Maximum Bending - 47.394 k-ft Maximum Shear= 16.20 k
Load Combination +D+S+f Load Combination +D+S+H
Location of maximum on span 20.253ft Location of maximum on span 6.000 ft
Span#where maximum occurs Span#2 Span#where maximum occurs Span#1
Maximum Deflection
Max Downward Transient Deflection 0.000 in 0
Max Upward Transient Deflection 0.000 in 0
Max Downward Total Deflection 14.635 in 32
Max Upward Total Deflection -6.601 in 20
Maximlim.Forces&Stresses for Load Combirfitthf'
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span# M V Mmax+ Mmax- Ma-Max Max Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Overall MAXirnum Envelope
Dsgn.L= 6.00 ft 1 -14.58 14.58 16,20
Dsgn.L= 1.52 ft 2 9.09 -14.58 14.58 16.20
Dsgn.L= 8.10 ft 2 103.79 9.09 103.79 14.97
Dsgn.L= 8.10 ft 2 145.32 103.79 145.32 8.41
Dsgn.L= 8.10 ft 2 147.39 133.69 147.39 4.72
Dsgn.L= 8.10 ft 2 133.69 68.90 133.69 11.28
Dsgn.L= 6.08 ft 2 68.90 -14.58 68.90 16.20
Dsgn.L= 1.97 ft 3 -0.00 -14.58 14.56 4.86
Dsgn.L= 4.03 ft 3 -6.56 6.56 3.26
+D+H
Dsgn.L= 6.00 ft 1 -5,47 5.47 6.08
Dsgn,L= 1.52 ft 2 3.41 -5.47 5.47 6.08
Dsgn.L= 8.10 ft 2 38.95 3.41 38.95 5.62
Dsgn.L= 8.10 ft 2 54.54 38.95 54.54 3.16
Dsgn.L= 8.10 ft 2 55.32 50.17 55.32 1.77
• Dsgn.L= 8.10 ft 2 50.17 25.86 50.17 4.23
Dsgn.L= 6.08 ft 2 25.86 -5.47 25.86 6.08
Dsgn.L= 1.97 ft 3 -0.00 -5.47 5.47 1.82
Dsgn.L= 4.03 fl 3 -2.46 2.46 1.22
+D+S+H
Dsgn.L= 6.00 ft 1 -14.58 14.58 16.20
Dsgn.L= 1.52 ft 2 9.09 -14.58 14.58 16.20
Dsgn.L= 8.10 ft 2 103.79 9.09 103.79 14.97
Dsgn.L= 8.10 ft 2 145.32 103.79 145.32 8.41
Dsgn.L= 8.10 tt 2 147.39 133.69 147.39 4.72
Dsgn.L= 8.10 ft 2 133.69 68.90 133.69 11.28
. •
c.- 1
. , ...i:,;:!,.i:A ,IN.... ilill+,F118 G.I.Acad2014120140760074Y07RF4HAKO-T.EC6
General BearnAnalysis, -..,.;!ii,iiiiit'ENERCAlle:INC,111:18312015,!Buildl8.15.1.:19,Vat:6,15.1.12
., . „„. .,.. .
Lic.if : KW-0600272e Licensee :VLMK CONSULTING ENGINEERS
Description: 25 112 x 5 1/8 GLB New
. .. . .. . . .
. General Beam Properties :!•..i•*,- c.: ' •. 1,,-.:.- ...
Elastic Modulus 29,000.0 ksi
Span#1 Span Length = 6.0 ft Area= 10.0 in62 Moment of Inertia = 100.0 inA4
Span#2 Span Length = 40.0 ft Area= 10.0 inA2 Moment of Inertia = 100.0 in64
Span#3 Span Length = 6.0 ft Area= 10.0 inA2 Moment of Inertia = 100.0 inA4
0(0 304)Sp 5(1.1 DIO 30.7(0 5061 Dia 304)S10 5?13I
V • • V • IP ir • • v i
DK/pm MO r8) 0(0178)
T I
Spin•to a X Spin•10.0 It g Span z 5.011
Applied Loads 111.. Service loads entered. Load Factors will be applied for calculations
Load for Span Number 1
Uniform Load: D=0.3040, S=0.5060 kilt, Tributary Width=1.0 f
Load for Span Number 2
Uniform Load: D=0.3040, S=0.5060 VI, Tributary Width=1.0 f
Point Load: 0 0.3780 k(al 4.0 fl
Point Load: D=0.3780 k R 20.0 ft
Point Load: D=0.3780 k(@.24.0 ft
. Load for Span Number 3
Uniform Load: D=0.3040, S=0.5060 MI Tributary Width=1.01
DESIGN SUMMARY
........
Maximum Bending= t 154.935 k-ft I Maximum Shear= 16.880 k
Load Combination +D+S+H Load Combination +D+S+H
Location of maximum on span 20.253ft Location of maximum on span 6.000 ft
Span if where maximum occurs Span if 2 Span if where maximum occurs Span if 1
Maximum Deflection
Max Downward Transient Deflection 0.000 in 0
Max Upward Transient Deflection 0.000 in 0
Max Downward Total Deflection 15.322 in 31
[ Max Upward Total Defiedion -6.919 in 20
......„.,......, „ ,
Maximum Fotaiii&Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span# M V Mmax+ Mmax- Ma-Max Mnx Mnx/Omegn Ch Rm Va Max Vnx Vnx/Omega
Overall MAXimum Envelope
Dsgn.L= 6.00 ft 1 -14,58 14.58 16,88
Dsgn.L= 1.52 ft 2 10.13 -14.58 14.58 16.88
Dsgn.L= 8.10 ft 2 108.21 10.13 108.21 15.65
Dsgn.L= 8.1011 2 152.19 108.21 152.19 8.71
Dsgn.L z 810 ft 2 154.93 140.12 154.93 5.17
Dsgn.L= 8.1011 2 140.12 71.65 140.12 11.73
Dsgn.L= 6.08 ft 2 71.65 -14.58 71.65 16.65
Dsgn.L= 1.97 ft 3 -0.00 -14.58 14.58 4.86
Dsgn.L= 4.03 ft 3 -6.56 6.56 3.26
+D+H
Dsgn.L= 6.00 ft 1 -5.47 5.47 6.76
Dsgn.L= 1.52 ft 2 4.45 -5.47 5.47 6.76
Dsgn.L= 8.10 ft 2 43.37 4.45 43.37 6.30
Dsgn.L= 8.10 ft 2 61.41 43.37 61.41 3.46
Dsgn.L= 8.10 ft 2 62.86 56.61 62.86 2.22
. Dsgn.L= 8.10 ft 2 56.61 28.61 56.61 4.69
Dsgn,L= 6.08 ft 2 28.61 -5.47 28.61 6.53
Dsgn.L= 1.97 ft 3 -000 -5.47 5.47 1.82
Dsgn.L= 4.03 ft 3 -2.46 2.46 1.22
+D+S+H
Dsgn.L= 6.00 ft 1 -14.58 14.58 16.88
Dsgn.L= 1.52 ft 2 10.13 -14.58 14.58 16.88
Dsgn.L= 8.10 ft 2 108.21 10.13 108.21 15.65
CONSULTING 503.222.4453 Job Dr. Battig Dental HVA1
. E N G I N E E R S 503.248.9263 Job No. 20140760
vlmk @vlmk.com 3933 SW Kell y Avenue • Portland • Oregon 97239-4393
www.vlmk.com Date 1/2015
v2.04 - Software Copyright 2014 VLMK Consulting Engineers. All Rights Reserved. Sheet NO. C-q
Wind Loads on Rooftop Structures and Equipment
Based on the 2012 International Building Code and ASCE 7-10, 29.5.1
/ TYPICAL SCREEN WALL
,---„/.0.`4,',
' / f i �if � Fh�
i^•
1...1... Ii •:�` '
H
_ -..// TYPICAL MECHANICAL UNIT
H O0\9-
B Exposure Category [Section 26.7.3]
- KZt = 1.00 Topographic Factor [Figure 26.8-1]
VULT = 120 mph Ultimate Wind Speed 3-Second Gust, 1.0W [Figures 26.5-1A, B, & C]
B = 80.00 ft Horizontal Dimension of Building Measured Normal to the Wind Direction
h = 30.00 ft Mean Roof Height of Building (Eave Height if Roof Angle < 101
HEIGHT = 3.10 ft Height of Rooftop Structure or Equipment
WIDTH = 6.90 ft Width of Rooftop Structure or Equipment, Perpendicular to Wind
DEPTH = 3.90 ft ., Depth of Rooftop Structure or Equipment, Parallel to Wind
H = 33.10 ft Height to Top of Structure or Equipment
a = 7.0 3-Second Gust-Speed Power Law Exponent [Table 26.9-1]
zg = 1200 ft Nominal Height of Atmospheric Boundary Layer [Table 26.9-1]
Kh = 0.701 Velocity Pressure Exposure Coefficient [Table 27.3-1]
Kd = ; .0.90 Wind Directionality Factor [Table 26.6-1]
qh = 0.00256KZKZtKdV2 (1.0W ULTIMATE LEVEL) [Equation 27.3-1]
qh = 23.2 psf Velocity Pressure at Ultimate Level [Equation 29.3-1]
GCr = 1.9 Horizontal: Force Increase & Gust Factor [Section 29.5.1]
GCr = 1.5 Vertical-Uplift: Force Increase & Gust Factor [Section 29.5.1]
Ar = 21.4 sf Area of Structure Normal to the Wind Direction (Horizontal face)
Ar = 26.9 sf Area of Structure Perpendicular to the Wind Direction (Vertical face)
Bh = 2400.0 sf Building Area Normal to the Wind Direction
Fh = 9h(GCr)At & F„ = 4h(GCr)Ar [Equation 29.5-2 & 29.5-3]
ph = 44.2 psf Horizontal Design Wind Pressure , (1.0W)
Pv = 34.9 psf Vertical (Uplift) Design Wind Pressure (1.0W)
Fh = 944.7 lb Horizontal Design Wind Force (1.0W)
F„ = 938.2 lb Vertical (Uplift) Design Wind Force t (1.0W)
T �/( CONSULTING 503.222.4453 Job Dr. Battig Dental HVAC
■ . 1� E N G I N E S R s 503.248.9263 Job No. 20140760
3933 SW Kelly Avenue • Portland • Oregon 97239-4393 vimk @vlmk.com Date 1/2015
www.vlmk.com
v2.31-Software Copyright 2014 VLMK Consulting Engineers. All Rights Reserved. Sheet No. C- W2)
Mechanical Unit Anchorage Design
Based on the 2012 International Building Code and ASCE 7-10
DESIGN INPUT I X
Seismic Parameters • 3 4 S -
iG
Site Class = D Design Site Class -i-c.Ft Y
Sos = 0.717,';Ii Design spectral response acceleration Ycg
0 = 1.00,1';'1; Overstrength factor(as required)
Ap = 2.5 IT [ASCE7 13.5-1 or 13.6-1] - 0 1 2 • -
Rp = 6.0 '`,!i [ASCE7 13.5-1 or 13.6-1]
Ip = .1.00 '';: [ASCE7 13.1.3] Xcg
z = 30 (ft) Attachment height from base of structure PLAN VIEW
h = 30 (ft) Average roof height of structure from base
Wind Parameters [ASCE 7-10]
PHOP.tz. = 44.2 (psf) Design wind pressure (psf) 1.0W G
Pururr =;;,' 34L;9! (psf) Design wind pressure (psf) 1.0W
2:cg
Mechanical Unit Parameters
Wp = r''!'7.551:!' (lb) Total weight
X = 83.3 (in) Base Dimension (max) SIDE VIEW
Y = 47.0 (in) Base Dimension (min)
Z = 36.4 (in) Height of Unit
Zcurb = 14.0 (in) Height of Curb, where occurs Load Combinations:
Xcg = 41.7 (in) Center of Gravity DESIGN: (ULTIMATE)
Ycg = 23.5 (in) Center of Gravity (0.9-.2SDS)D+ QE 0.90 + 1.0W
Zcg •: 24.3 (in) Center of Gravity (excluding curb) ALLOWABLE: (ASD)
(0.6-.14SDS)D+ 0.782E 0.60 i 0.6W
• ANALYSIS
Base Shear:
Seismici 0.4a S 11'
F1 = P ns r(I+2L)= 271 lbs 51.6.SDy.IPWP = 866 lbs OK
Rp/Ip l li Controls _>0.3S„/1,W1, = 162 lbs OK
Base Shear, Vu S2E = 271 lbs at SOE = 1.00
Wind: Vuw = 1288.7 lbs at 1.0W Total Base Shear = 1289 lbs. Wind
To(4)Anchors/Comers = 773 (asd) Wind
Anchor Shear:
Seismic:
Anchor: dx dx^2 dy dy^2 Design eccentricity = I r'`''
1 41.65 1734.7 23.5 552.25 ex = 2 ey = 1.175
2 41.65 1734.7 23.5 552.25 Mx-x = 564 in-lbs My-y = 318 in-lbs
3 41.65 1734.7 23.5 552.25 Y Direction X Direction
4 41.65 1734.7 23.5 552.25 V1,3 = 71 lbs V1,2 = 71 lbs
6938.9 2209 V3,4 = 71 lbs V3,4 = 71 lbs
V„max = 322 lbs Wind
Wind: V1,2,3,4 = 233 lbs = 193 (asd) Wind
Each Anchor/Corner
Overturning / Uplift: at DE = 1.00 and 1.0W
Mot = 10358 lb-In Seismic 0 E
Mot = 32474 lb-In Wind 1.0W
• Mres-x = 23791.9 lb-in Seismic 0 E Mres-y = 13423.9755 lb-in Seismic 0 E
28301.2 lb-in Wind 1.0W = 15968.25 lb-in Wind 1.0W
Net Bolt Tension: X Direction Y Direction Tumax* = 413 lbs wind
Tx* = 262 Ty* = 413 lbs = 236 (asd) Wind
*negative(-)values Indicate there Is no net uplift Each Anchor/Corner
- f
• nnox Industries Inc. - Product Submittal
ystem ID:4-TON GAS/ELECTRIC
Package Model:KGA048S4D Description:PKGGEJ4 TON/150KB/460-3
HEATING PERFORMANCE
Unit Type Packaged Gas
Electric Gas Supply Connection 0.50 (in.)
H/E Lowlnput 113000 (Btuh) I-LIE Heat Rise 69.4 (°F)
H/E LowOutput 90000 (13tuh) AFUE/TlretmalEff 80
H/E HighInput 150000 (Btuh) Number of Heating Stages 2
WE HighOutput 120000 (Btuh) Gas Supply Pressure 7 (in.WC)
System HcatOulput 120000 (Btuh)
COOLING PERFORMANCE
Refrigerant R-410A Number Compressors 1
ARI EER 11.0 Number of Cooling Stages 1
ARI SEER 13.0 Condensate Drain Size 1.00 (in.)
ARI Total Power 4400 (W) Cooling OutdoorDB 95.0 (°F)
ARI GrossTotalCool 50000 (Btuh) Cooling CoudeuserDB 95.0 (°F)
ARI NetTotalCool 48000 (Btuh) Cooling MixedWB 80.0 (°F)
Coil GrossTotalCool 50591 (Btuh) Cooling MixedWB 67.0 (°F)
Unit NetTotalCool 50591 (Btuh) Coil DischargeDB 57.9 (°F)
Coil GrossSensCooJ 40243 (Btuh) Coil DischargeWB 57.6 (°F)
Unit NetSensCool 40243 (Btuh) Unit DischargeDB 57.9 (°F)
Tube/Fin Refrigerant Charge 8 LBS. I0 OZ. Unit DischargeWB 57.6 (°F)
Coil MoistnreRemoval 9.8 (!b/hr)
System MoistRemoval 9.8 (1b/hr)
SUPPLY FAN PERFORMANCE
Supply Airflow 1789 (cftn) TotalStaticPress 0.59 (in.WC)
ExtStaticPress Supply 0.50 (in.WC) Wet Coil Static Press 0.05 (in.WC)
SupplyFan NomPower 0.50 (hp) Gas WE Static Press
- Supply Fan Type CAV Direct Drive Air Filter Qty 4( �WC)
SupplyDrive Speed HIGH Air Filter Length 16.0 (in.)
Air Filter Width 20.0 (in.)
Air Filter Thickness 2.0 (in.)
ELECTRICAL
Voltage 460V 3Ph SupplyFan FLA 1.5 (amp)
Frequency 60 (Hz) CondensingUnit FLA 1.] (amp)
System MCA 11.0 (amp) CondenserFan Power 250 (W)
System MOCP 15 (amp)
Compressors RLA 6.2 (amp)
Cooling FLA Total 8.8 (amp)
Unit Oper Range-Nom Voltage +1-.10%
DIMENSIONS
Cabinet Width 47.0 (in.) Downflow Supply Length 18.0 (in.)
Cabinet Length 83.3 (in.) Downflow Supply Width 20.0 (in.)
Cabinet Height 36. (in. Downflow Return Length 11.0 (in.)
Total Weight 590 (1b)_11 Downflow Return Width 29.0 (in.)
SOUND
Outdoor Sound Rating 75 (db)
{
Protect: 3000469017 Battig
Last red On: DAN A.GIVENS
Quote: 4000557656 BatUg
!'age 3 of 8 • Prepared On:2015-01-14
Phone:503-231-7717
N
Pi .../1-774.0„,p-c -1-2._ 6,(47--f-) - r-P-T-1-4 - (
elIaNOEDYO I4LmCm MRM01 TL•.uat
RE+61G tl
Attn: Tag: 20W05
R-a'• De4;R1F7C44 Uti[ APP!Rr.®
Approval: 02 LOWERED CURS KfiG M 170M ar to I2 1130/0'
46 11/16" {
29 M18'
14 NW I•--
• 7RETURNIUR
331 1 15/18' �'
L f
1 4� '. \ SUPPLY AIR
I 1
I 'i ll
\ /
EXISTING CURB LAYOUT `,��� -
50 I vier
30 I/16'
•
2 IN' '" 26 1/16-
1 �X,la L-- 2,M
1
22 Srir REfURN
26 16"
SUPPLY
,(11T
I
79 1W- - 1
■
lam—41 1I1'
or { + 1i s-
I 7012' J -r--I 57' -I-1--3- .
iladdNM.�. 6YSIvUM i*rUm YC.rw 3a5{A. em1
•
Pnsnn Dq•}OC11R,of IGJI Nat ILs.vATCU76 a@O.i 55,541 09
CUM�a UM I is (1109 9672
1 a.aS arms
3 nail a9�
...... A 0115? h08
OASMIaruu •......0 a*" -°u 20W05 i
CURB SHOWN IS CDI STANDARD CONFIGURATION I6• +Nr
Naps. CDi RESERVES THE RIGHT TO CHANGE LAYOUT _
1 1.S ADDED TO OLD CURB O.D WITHOUT NOIIFICATION.IF CURB IS NEEDED IN A �� "` FrmT,F.an,nr as.20011 �w QUOTE#:
2 kAIER1AL 16 GALYANIc'ED STEEL %+°��' tTaaa'TtL,gl>n IIIN J
3 GASKET PROVIDED av►rrxcuRa DIFFERENT CONFIGURATION GDI MUST BE NOTIFIED
VERIFY WRf PoNL-I IRA0 ^��
4 9 SULATIC61:1'1 la LB DENSITY PRIOR TO PLACING AN ORDER. ,1•1.1_ arssnow CDI "'� :e � �1-2oD5.2oso
:FAR UaIL,..�aa owww m ac Al y „•, j R•�15r1.7'+ra
:b*itiN- ' . - ' . • •' '
a7anant •r„s 145 1..., 1 •• 1