Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
FF2 011-0004 5 . Woo f 5w -yard . - Global Project Values: SILENT Project Name:IPacktrust-SIEMENS I _ Standby Hours: 24 le KNIGHT Project ID: Alarm Mins: 5 Prepared By: Gary Tauscher Derating Factor: 1.2 5495 Power Expander Calculations Date: 2/2/2011 Voltage Drop Warning Version 02.18.09 Threshold%• 10 Panel ID: 5495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location:, 12908 SW 68TH PARKWAY I Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name Standby..: Alarm &Type 1000 Ft. One-Way Ohms EOL p 5495 5495 Pwr Module 1 0.075 0.205 NAC#1 ` 5495 Circuit 1 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% NAC#2 ,i 5495 Circuit 2 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% NAC#3 5495 Circuit 3 0.000 1.049 #14 Solid 2.52 230 1.16 19.18 5.96% I NAC#4 5495 Circuit 4 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Aux 5495 Aux Power Out 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Total Standby Current(Amps) 0.075 1.254 Total Alarm Current(Amps) • Standby Time In Hours . 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 1.800 0.105 Total Alarm AH Required Total Combined AH Required 1.90 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.29 Configure Circuits Print Page ) J till I I Circuit Configuration Project Information Project Name: Packtrust-SIEMENS Project ID: 0 Prepared By: Gary Tauscher Date: 2/2/2011 Ckt. Number: NAC#1 Panel ID: 5495 Ckt, Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Unused 0.000 0.000 0.000 • 0.000 Unused 0.000 • 0.000 0.000 0.000 Unused 0.000 0.000 _ 0.000 0.000 ~ Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0 000 Ckt. Number: NAC#2 Panel ID: 5495 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Unused 0.000 • 0.000 0.000 0.000 0 Unused 0.000 • 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0.000 • 0.000 Totals 0 000 0.000 Ckt. Number: NAC#3 Panel ID: 5495 , Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 System Sensor P2/PC2 Horn/Strobe(115cd) 0.000 0.229 0.000 0.687 2 System Sensor S/SC Strobe(95cd) 0.000 0.181 0.000 • 0.362 Unused 0.000 - 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 .._. 0.000 Totals 0.000 1.049 Ckt. Number: NAC#4 Panel ID: 5495 Ckt. Name: 5495 Circuit 4 Max Circuit Current: 3 Amps • Qty Device Current Draw Each Current Draw Total Standby • Alarm Standby Alarm Unused 0.000 • 0.000 0.000 - 0.000 Unused _ 0.000 _ 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: Aux • Panel ID: 5495 Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm ' Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 _Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0_000 t