Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
- 215\c-t —c%GO‘6 �Z ----z-7DD sJ _a.r-t term t!►_. WEsuaacRVwoENCOURABEMCEra RIimal JANUARY 2014 Y FIRESTOP CO. r, F` .. AUTOMATIC FIRE PROTECTION p 3203 NE 65th Street, Space 2 Vancouver, WA 98663 Phone: 360-718-8604 Fax: 360-718-8603 PRODUCT DATA FOR TIGARD OUTLOT RETAIL BUILDINGS A) OVERHEAD PIPE D) SPRINKLERS Allied Pipe Sch 10&Sch 40 TYCO TY-B SR SSU SSP Allied Pipe Dyna-Flow TYCO Spare Sprinkler Cabinet B) FITTINGS ANVIL Cast Iron Threaded Fittings Star Cast Iron Threaded Fittings Flanged Adapter Mech Tees TYCO Grooved Fittings - TYCO Grooved Couplings Welded Outlets C) DEVICES TYCO Butterfly Valve BFV-N TYCO Check Valve 590F TYCO Riser Mainifold 513 Potter OSYSU Tamper Switch Potter Alarm Bell Wilkins Ball Valve Ball Drip Valve Identification Signs Tolco Hangers AFCON Sway Bracing I r Stamp Here Scheduk' 1O/Sthédü•Ie-4O Submittal Data Sheet Fully Listed and FM Approved Sprinkler Pipe 7'7= 'r' Sch-40'Specifications NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR When you specify Schedule-10/Schedule-40 sprinkler pipe from Allied Tube&Conduit,you In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m - get UL listed and FM approved products.Although these products do not require separate 1" 1.049 1.680 2.05 1 approvals,Schedule-10/Schedule-40 gives you the extra quality assurance you demand. 25 26.6 2.5 3.05 - Our Sch-10(1-1/4"-8")pipe and Sch-40(1"-2-1/2")pipe have passed the same 11/4" 1.380 2.270 2.93 1 thorough lab testing as our other listed pipe products,and receive periodic mill inspections 32 35.1 4.36 4.36 - from both UL and FM agents to ensure consistent quality. 11/2" 1.610 2.720 3.61 1 40 40.9 4.0 5.37 - Galvanized Pipe Schedule-10/Schedule-40 product can be"hot-dip"galvanized 2" 2.067 3.650 5.13 1 to meet FM requirements. 50 52.5 5.4 7.63 - 2'/r" 2.469 5.790 7.86 1 Superior Coating Our advanced formula mill coating offers a clean,durable 65 62.7 8.6 11.73 - surface that is also paintready for custom color applications without special preparation. Sch-10'Specificatwns , , American Made Able to meet"Buy American"requirements,and is available NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR through distributors in the USA,Canada,Mexico and Latin America. In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m - 1'/" 1.442 1.810 2.525 7.0955 Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance 32 36.6 2.7 3.75 - with the following:ASTM A135,Type E Grade A,and NFPA 13.Both pipe products have a 11/2" 1.682 2.080 3.04 5.6570 working pressure rating of 300 psi maximum and also meet the stringent requirement for 40 42.7 3.1 4.52 - - the following tests:Welded Outlets,Hydrostatic Pressure,Side Wall Rupture,Vibration Test. 2" 2.157 2.640 4.22 4.5827 50 54.8 3.9 6.28 - 2'/" 2.635 3.530 5.89 3.5196 65 66.9 5.3 8.77 - 3" 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4" 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5" 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6" 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 - ® c® w Project: Sprinkler Contractor: Date: P Engineer: Specification Reference: System Type: Locations: Comments: Pallied Cu stomer Service (800)882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com •16100 S Lathrop Ave. •11350 Noncom Rd. •2525 N 27th Ave. •600 Dean Sievers Place TUBE& CONDUIT° Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 Morrisville,PA 19067 02008-10 Tyco Int.,All Rights Reserved,STP-S5-4-NON-1003 • Dyflä-FIow Submittal Data Sheet • High Strength Steel Pipe « „flAr'n of ..Pea_; ttbnsr�, x r:. Dyna Flow'pipe is the"original"high strength lightwall sprinkler pipe.Dyna Flow has NPs Nominal I.D. Wt. Wt.(H20 Filled) CRR outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 In; - In. gi Lbs/Ft;0.830 Lbs/1.31 Unthreaded pipe.Lightweight,easy to cut and easy to handle for installation.Dyna-Flow is a valuable addition 25 3 .3 01.20 1.95 2.1 to any fire protection system. 25 30.3 1.2 1.95 - 11/4" 1.536 1.059 1.87 1.55 Additional Benefits Lightweight and easy to install,resulting in more efficient use of 32 39.0 1.6 2.78 - your freight and labor dollars.Provides stability needed to comply with standard hanger spacing 11/2" 1.728 1.667 2.71 3.44 - (15 ft O.C.)per NFPA.Available in standard lengths for your convenience,or can be ordered in 40 43.9 2.5 4.03 - custom lengths upon approval.Fast cutting and welding,as well as easy roll grooving and end 2" 2.203 2.104 3.79 2.78 preparation.Available in Factory roll grooved form for quicker shop turnaround.Clean,durable mill 50 56.0 3.1 5.64 - coating provides longer"shelf life"and acts as an excellent primer for custom paint applications. 21/2" 2.703 2.564 5.10 1.60 65 68.7 3.8 7.59 Superior Hydraulics With an inside diameter of up to 11%larger than Schedule 40 3" 3.314 3.387 7.18 1.48 and up to 7%larger than Schedule10,Dyna-Flow pipe hydraulics are exceptional.Larger I.D.s 75 84.2 5.0 10.69 enable Dyna-Flow,and related components,to be clown-sized within the system,thus increasing 4" 4.310 4.473 10.86 1.00 the potential for job cost savings.For complete Hazen-Williams charts,refer to"Dyna-Flow 100 109.5 6.7 16.16 . Hydraulic Data Tables." - Coatings & Fabrication Dyna-Flow products are coated with an environmentally ® c U) approved and specially formulated modified-acrylic or water-based coating.This durable,exterior •••••.E• . black coating is paintable and acts as an excellent primer that is resistant to weathering and U.V.degradation from outdoor storage.Metallurgical properties provide excellent fabrication characteristics for end prep finishes,welding and roll grooving.No special process or equipment is needed for fabrication and installation. • American Made Able to meet"Buy American"requirements,and is available through distributors in the USA,Canada,Mexico and Latin America. Specifications &Approvals Dyna-Flow pipe is manufactured to meet ASTM A 795,Type E Grade A,and are in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow are UL Listed,FM Approved and ULC Listed. Dyna-Flow is UL/ULC Listed for use with roll grooved,plain-end couplings,and welded joints for wet,dry,pre-action and deluge systems.It is FM Approved for roll grooved,plain-ended,and welded joints for wet systems.Refer to appropriate documentation for up-to-date listing and approval information.Dyna-Flow is now available"hot-dip"galvanized*and has been - specifically approved by FM for dry systems uses. *Must be ordered in 10 bundle increments. • Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 9:`l v hied Customer Service (800)882-5543 Fax: (800) 659-7730 www,alliedtube-sprinkler.com `�, • 16100 5 Lathrop Ave. •11350 Norcom Rd. •2525 N 27th Ave. •600 Dean Sievers Place TUBE & CONDUIT° Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 Morrisville,PA 19067 02008-10 Tyco Int.,All Rights Reserved,STP-S2-4-NON-1004 Standards and Specifications 4*)"' INTERNATIONAL, • Dimensions Material Galvanizing Thread Pressure Federal/Other Rating M.I.Fittings Class 150/PN 20 ASME B16.3. • ASTM A-197 ASTM A-153 ASME B1 20.1+ ASME B16.3• ASME B16.3"" Class 300/PN 50 ASME B16.3. ASTM A-197 ASTM A-153 ASME B1 20.1+ ASME B16.3- M.I.Unions Class 150/PN 20 ASME 816.39• ASTM A-197 ASTM A-153 ASME B1 20.1+ ASME 816.39• ASME 816.39"• Class 250 ASME B16.39• ASTM A-197 ASTM A-153 ASME B1 20.1+ ASME B16.39. Class 300/PN 50 ASME B16.39• ASTM A-197 ASTM A-153 ASME B1 20.1+ ASME 816.39• Cast Iron Threaded Fittings Class 125 ASME B16.4• I ASTM A-126 (A) ASTM A-153 ASME B1.20.1+ ASME 816.4• ASME 816.411 Class 250 ASME 816.4• ASTM A-126 (A) ASTM A-153 ASME B1.20.1+ ASME 816.4• ASME 816.411 C.1.Plugs and Bushings ASME 816.14• I ASTM A- 126 (A) ASTM A-153 ASME B1.20.1+ I ASME 816.4• I WW-P-471 C.1.Drainage Threaded Fittings ASME 816.12• ASTM A-126 (A) ASTM A-153 ASME 81.20.1+ ASME B16.12• I C.1.Flanges and Flanged Fittings Class 125(1"-12") ASME B16.1. ASTM A- 126 (A) or (B) ASTM A-153 ASME B1.20.1+ ASME 816.10 ASME 816.1• Class 125(14"-up) ASME 816.1• ASTM A-126 (B) ASTM A-153 ASME B1.20.1+ ASME 816.10 ASME 616.1• Class 250(11'-12") ASME 816.1• i ASTM A- 126 (A) or (B) ASTM A-153 ASME 81.20.1+ ASME B16.10 ASME B16.1. Class 250(14"-up) ASME B16.1• ASTM A-126 (B) 1 ASTM A-153 ASME 81.20.1+ ASME B16.10 ASME B16.1• Forged Steel Threaded Fittings Class 2000,3000, ASTM A105, 6000 ASME 816.11• ASTM A182, ASMEB1.20.1+ ASME 816.11. ASTM A350 Pipe Nipples Steel Pipe ASTM A53 ASME B1.20.1+ -Welded ASTM A733 Type F or Type E WWN 351 Steel Pipe ASME 81.20.1+ -Seamless ASTM A733 I ASTM A106 Gr. B WWN 351 (High Temp.) Brass ASTM 843 WWN 351 •The Standard •an American National Standard (ANSI) +ASME 81.20.1 was ANSI B2.1 •Formerly WW-P-501 *`Formerly WW-P-521 '''Formerly WW-U-531 www.anvilintl.com (12/10/01) _ C.I. THREADED FITTINGS STAR°PIPE PRODUCTS V LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Cast iron threaded fittings are UL,ULC listed and factory mutual approved for 300 psi service.Gray iron per ASTM A126 class B.Dimensions conform to ANSI B16.4 class 125 except plugs conform to ASME B16.14.Threads are NPT per ANSI/ASME B1.20.1. J._. 1 r/// 1 I I• 1 ' ' CAST IRON STRAIGHT TEE CAST IRON 90 DEGREE ELBOW NOMINAL ' ITEM ' MAX. DIMENSIONS' WEIGHT NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE (INCH) # P.S.I. A B PIECE 1 CT333 300 1.50 1.50 1.21 1 CB90033 300 1.50 1.50 0.95 11/4 CT444 300 1.75 1.75 1.87 11/4 CB90044 300 1.75 1.75 1.34 11/2 CT555 300 1.94 1.94 2.51 11/2 CB90055 300 1.94 1.94 1.80 2 CT666 300 2.25 2.25 3.96 2 CB90066 300 2.25 2.25 2.90 21/2 CT777 300 2.70 2.70 6.45 21/2 CB90077 300 2.70 2.70 4.75 - 1 _ :' ) A ; A - CAST IRON RED. COUPLING ' NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH CAST IRON 45 DEGREE ELBOW (INCH) # P.S.I. A PIECE NOMINAL ITEM MAX. DIMENSIONS WEIGHT 1X1/2 CRC031 300 1.70 0.62 SIZE CODE WORKING EACH 1X3/4 CRC032 300 1.70 0.80 (INCH) # P.S.I. A B PIECE �� 1 CB45033 300 1.12 1.12 0.84 1 114 CB45044 300 1.29 _1.29 1.40 1112 CR45055 300 1.43 1.43 1.80 2 C645066 300 1.68 1.68 2.79 • J 1 • --__ CAST IRON RED. 90 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT 1 i r SIZE CODE WORKING EACH .•,.(INCH) # P.S.I. A B PIECE 1 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 CAST IRON PLUGS 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 NOMINAL ITEM MAX. DIMENSION WEIGHT 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 . 1 1/4X1 CB90043 300 1.58 1.67 1.16 SIZE CODE WORKING EACH 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 (INCH) # P.S.I. A PIECE 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1/2 CPL001 300 0.94 0.10 1 1/2X1 CB90053 300 1.65 1.80 1.51 3/4 CPL002 300 1.07 0.17 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 1 CPL003 300 1.25 0.28 2X1/2 CB90061 300 1.49 1.88 2.00 11/4 CPL004 300 1.36 0.44 2X3/4 CB90062 300 1.60 1.97 2.05 11/2 CPL005 300 1.45 0.62 2X1 CB90063 300 1.73 2.02 2.10 2 CPL006 300 1.56 0.91 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CR90065 300 2.02 2.16 2.60 Page 19 C.I. THREADED FITTINGS STAR°PIPE PRODUCTS U L LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS • I NOMINAL ITEM MAX. DIMENSIONS WEIGHT c SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CX033 300 1.50 1.50 1.54 _ _ 11/4 CX044 300 1.75 1.75 2.40 • [ 1 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST IRON REDUCING TEE _----- NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH . [ (INCH) # P.S.I. A B C PIECE 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 . 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X3/4 CT432 300 1.45 1.37 1.62 1.38 1 114X1 X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 114X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 1 112X1 X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 114X1/2 CTS41 300 1.41 1.34 1.66 1.58 1 1/2X1 114X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 - 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 . 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 112X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 114X2 CT646 300 2.25 2.10 2.25 2.80 . 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 _2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 _ 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 2x2x2 1/2 _ CT667 300 2.60 _ 2.60 _ 2.39 5.10 Page 20 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.04 VICTAULIC'IS AN ISO 9031 CER III IED COMPANY Style 744 FireLock® Flange Adapter VAC ' +,.LIB with Vic-Plus TM Gasket System Gasket System PRODUCT DESCRIPTION Style 744 FireLock Flange adapter is designed for directly incorporating flanged components with ANSI y � - - CL. 125 or CL. 150 bolt hole patterns into a grooved pipe system.Sizes 2-8•(50 -200 mm)are hinged•' , foreasy handling with integral end tabs which facilitate assembly. ,! _ ri '' ,�' l'.2 The design incorporates small teeth inside the key shoulder I.D. to prevent rotation. ir g �4 Because of the outside flange dimension,FireLock Flange adapters should not be used on FireLock fittings.When wafer or lug-type valves are used adjoining a Victaulic fitting,check disc dimensions to 4 r�R I assure proper clearance. t,.-� FireLock Flange adapters should not be used as anchor points for lie-rods across nonrestrained joints. Mating rubber faced flanges,valves,etc.,require the use of a FireLock Flange washer. 2-8"Sizes FireLock Flange adapters with Vic-Plus gaskets do not require lubrication.The gasket must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. A Ar 4=1 Style 744 FireLock Flange Adapters with the Vic-Plus TM Gasket System are designed and /M.31t recommended for use ONLY on fire protection systems. _A L"' / An Vic-Plus Gasket System: MENVictaulic"now offers a gasket system which requires no field lubrication on wet pipe systems.The Vic- �_ era Plus1M System(patented)is dry,clean,and non-toxic. It reduces assembly time substantially and 1 I � , eliminates the mess and chance of over-lubrication.Please refer to the latest copy of the Victaulic Field Installation Handbook(I-100)for supplemental lubrication requirements. ow See Victaulic (Exaggerated for clarify) publication 10.01 for details. DIMENSIONS • Style 744 Sealing Sizes 2-8"(50-200 mm) Surface Dimensions ANSI Class 125 and 150 Flange Pipe Size Max. Max. Inches/mat Incheslmillimeters Aprx Actual Work End Wgt. Z h Nominal Outside Press.' Load' No. Boll Each Diameter Diameter PSI Lbs. Bolts t Size t "A" "B" Lbs. • InJmm InJmm kPa N Req'd. Inches Max. Min. W X Y Z kg <-1 2 2.375 175 775 2.38 3.41 6.75 6.00 4.75 0.75 2.7 0040"...a"--.- 50 60.3 1200 3450 4 s/e X 2;h 60 87 172 152 121 19 1.2 1/ Y W 2'/2 2.875 175 1135 4 5/a X 3 2.88 3.91 7.88 7.00 5.50 0.88 4.2 / 1_ 65 73.0 1200 5050 73 99 200 178 140 22 1.9 �� 3 3.500 175 1685 s 3.50 4,53 8.44 7.50 6.00 0.94 4.8 �0 \O 48.580.90 80 88.9 1200 7500 4 /s X 3 gq 115 214 191 152 24 2,2 Q O 4 4.500 175 2780 s 4.50 5.53 9.94 9.00 7.50 0.94 7.1 100 114.3 1200 11045 8 /e X 3 114 141 252 229 191 24 3.2 Note:Gray area of mating face must 5 5.563 175 4250 5.56 6.71 11.00 10.00 8.50 1.00 8.3 be free from gouges,undulations or 125 141,3 1200 18920 8 1/a X 3'/2 141 171 279 254 216 25 3.8 deformities of any type for effective . sealing. 611 6.625 175 6030 1 , 6.63 7.78 12.00 11.00 9.50 1.00 9.3 150 168,3 1200 26840 8 /�X 3/z 168 198 305 279 241 25 4,2 88 8.625 175 10219 1 8.63 9.94 14.63 13.50 11.75 1.13 13.9 200 219.1 1200 45475 8 /,X 3/_ 219 252 372 343 298 29 6.3 'Refer to notes below. 1Total bolls required to be supplied by installer.Boll sizes for conventional flange-lo-flange connection.Larger bolts are required when Vic-Flange adapter is utilized with wafer-type valves. 4'Not available with Vic-Plus gasket system.Lubrication Is required. NOTES •Working Pressure and End Load are total,from all internal and external loads.based on standard weight steel pipe.standard roll or cut grooved In accordance with Victaulic specifications.Contact Vlclaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 limes the figures shown. Style 744 FireLock Flange adapters provide rigid joints when used on pipe with standard roll or cut groove dimensions and consequently allow no linear or angular movement at the joint. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. REGISTERED TRADEMARK OF VICTA111.IC-9 COPYRIGHT 2004 VICTAULIC-PRINTED IN OS A. 1417 REV D Victaulic Company of America•Phone:1-800-PICK-VIC(1.800.742.5842)•Fax:610-250-8817•e-mail:pickvic @victaulic.com Victaulic Company of Canada•Phone:905-884-7444•Fax:905-884-9774•e-mail:vlccanada @vlclaulic.com Vlclaulic Europe•Phone:32-9-381-1500•Fax:32-9-380-4438•e-mail:viceuro@viclaulic.be Victaulic America Latina•Phone:610-559-3300•Fax:610-559-3608•e-mail:vical@viclaulic.com 1 C}4 a u I 1 C`' Victaulic Asia Pacific•Phone:65-6235-3035•Fax:65-6235-0535•e-mail:vicap@victaulic.com 10.04 VIC-FLANGE ADAPTER NOTES i The Style 744 (2-8'150-200 mm)design incorporates small teeth inside the key shoulder I.D.to prevent rotation. 2 FireLock Flange adapter should not be used on FireLock fittings.When wafer or lug-type valves are used adjoining a Victaulic fitting,check disc dimensions to assure proper clearance. 3 FireLock Flange adapters should not be used as anchor points for tie-rods across nonrestrained joints. Mating rubber faced flanges,valves,etc.require the use of a FireLock Flange washer. • 4 Area A-B noted in the above&awing must be free from gouges,undulations or deformities of any type for effective sealing. 5 FireLock Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. 6 Flange Washers:FireLock Flange adapters require a smooth hard surface at the mating flange face for effective sealing.Some applications for which the Vic-Flange adapter is otherwise well suited do not provide an adequate mating surface.In such cases,it is recommended that a metal Flange Washer be inserted between the FireLock Flange adapter and the mating flange to provide the necessary sealing surface. Typical applications where a Flange Washer should be used are: A When mating to a serrated flange:a standard flat flange gasket should be used adjacent to the serrated flange and then the Flange Washer is Inserted between the FireLock Flange adapter and the flange gasket. B When mating to a wafer valve:where typical valves are rubber lined and partially rubber faced(smooth or not),the Flange Washer is placed between the valve and the FireLock Flange adapter. c When mating a rubber faced flange:the Flange Washer is placed between the FireLock Flange adapters and the rubber faced flange. D When mating AWWA cast flanges to IPS flanges:the Flange Washer is placed between two FireLock Flanges.The hinge points must be oriented approximately 90°to each other.If one flange is not a FireLock Flange adapter(e.g.flanged valve),then a standard flat flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the FireLock Flange adapter. E When mating to components(valves,strainers,etc.)where the component flange face has an insert: follow the same arrangement as in Application 1. F When mating to a Series 705-W Butterfly valve,Style 744 may only be used on one side of the connection. When ordering Flange Washers,always specify product style(Style 744)and size to assure proper Flange Washer is supplied. MATERIAL SPECIFICATIONS Flange Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Coating: Black enamel • Optional:Hot dipped galvanized Bolts/Nuts: Supplied by installer Gasket: • Grade"E"EPDM-Type A Vic-Plus Gasket System A (Violet color code).FireLock products have been Listed by Underwriters Laboratories Inc.and Ap- proved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated work- _ ing pressure using the Grade'E"Type A Vic-Plus Gasket System,requiring no field lubrication for most installation conditions. A Standard gasket approved for dry pipe systems to-40'F(-40`C).Based on'typical'pipe surface conditions,supplemental lubricant Is recommended for services Installed below 0•F(-18'C)and for all dry pipe systems or systems to be subjected to air tests prior to being filled with wafer.Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. • This product shall he manufactured by Victaulic Company.All products to be Installed In accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without Incurring obligations. 2 Style 744 FireLock' Flange Adapter �; Worldwide www.tyco-fire.com $ f .': rmtx Contacts GRINNELL G-FIRE Figure 522 • . • Sprinkler Outlets General standards of any other authorities hav- ing jurisdiction. Failure to do so may re- Description suit in serious personal injury or impair —t p the performance of these devices. The GRINNELL G-FIRE Figure 522 - Sprinkler Outlet is an economical alter- The owner is responsible for maintain- native to welded pipe outlets on steel ing their mechanical system and devic- ;' 5'j, -1= pipe.The Figure 522 Sprinkler Outlet es in proper operating condition. The --' ".:`i_• may be used with full lengths of pipe installing contractor or device mane- -. and eliminates threading and welding, facturer should be contacted with any decreasing waste and installation time. questions. _ The Figure 522 Sprinkler Outlet may be -_- . used in wet pipe,dry pipe,and deluge Technical systems. Data 1/2 inch and 3/4 inch nominal out- let sizes are intended for use in fire Approvals ® ® rr protection systems leading to a direct UL, FM, ULC,VdS,and LPCB la, connection to a sprinkler only. The 1 r inch nominal outlet size is intended for Maximum Working Pressure VdS use in fire protection systems leading 300 psi(20,7 Bar) to a direct connection to a sprinkler or For Fire Protection pressure rating,listing a connection to system piping. These Sizes and approval information,contact fittings should be used for hydraulically • R_un Sizes Tyco Fire Suppression&Building Products. calculated systems only. 1 ,1-1/4", 1-1/2",2",2-1/2",76,1 mm (DN25,DN32, DN40,DN50,DN65) Gasket NOTICE • Outlet Sizes Grade"E" EPDM, Green color code Never remove any piping component NPT or ISO 7-1 Pipe Threaded -30°F to 230°F(-34°C to 110°C) yPP g nor correct or modify any piping de- 3/8", 1/2;3/4",1" See Data Sheet TFP1865 for addi- ficiencies without first de-pressurizing (DN10,DN15, DN20,DN25) tional gasket information. and draining the system. Failure to do Housing Materials Friction Loss so may result in serious personal injury, Ductile Iron conforming to Equivalent length of 1 Inch Schedule 40 property damage,and/or impaired de- ASTM A 536, Grade 65-45-12 q g vice performance. pipe is 15 ft(4,6 m). It is the designer's responsibility to se- Finish Hazen Williams coefficient=120 lect products suitable for the intend- • Zinc electroplate conforming to ed service and to ensure that pressure ASTM B 633 Type III ratings and performance data are not . Red(RAL3000)painted finish for - exceeded. Material and gasket selec- ISO Thread only tion should be verified to be compat- ible for the specific application.Always • Orange painted finish for read and understand the installation NPT Thread only • instructions. Bolts The GRINNELL G-FIRE Figure 522 Conforming to DIN 933, Sprinkler Outlet described herein must M8 x 30 mm Class 8.8 be installed and maintained in compli- ance with this document, as well as Flange nuts conforming to DIN 934, - with the applicable standards of the Class 8 Approval agency, in addition to the Page 1 of 4 MARCH 2013 TFP1865 TFP1865 Page 2 of 4 B s — C� r` lip tr -.41 r E 'j ■ Iff 1111 Nominal Pipe Size Outlet Size Max.$ Nominal Dimensions Approx. Nominal NPT or Outlet Inches(mm) Weight Run Size O.D. ISO 7-1 End Load Lbs. ANSI Inches I(m ,s Pipe Threads Lbs.(kN) A B C D E (kg) (DN) 1/2 165.9 1.00 3.40 1.94 0.56 1.00 0.9 (0,738) (25,4) (86,4) (49,3) (14,3) (25,4) (0,4) 1 1.315 259.9 1.64 3.40 1.94 1.14 1.00 1.1 (DN25) (33,7) 3/4 (1,156) (41,7) (86,4) (49,3) (29,0) (25,4) (0,5) 1 259.9 1.83 3.40 2.25 1.26 1.00 1.1 (1,156) (46,5) (86,4) (57,2) (32,0) (25,4) (0,5) 3/8 165.9 1.22 3.78 2.25 0.91 1.06 0.9 (0,738) (31,0) (96,0) (57,2) (23,1) (26,9) (0,4) 165.9 1.22 3.78 2.25 0.78 1.06 0.9 1-1/4 1.660 1/2 (0,738) (31,0) (96,0) (57,2) (19,8) (26,9) (0,4) (DN32) (42,4) 3/4 259.9 1.83 3.78 2.25 1.33 1.06 1.1 (1,156) (46,5) (96,0) (57,2) (33,8) (26,9) (0,5) 1 406.9 2.00 3.78 2.25 1.44 1.06 1.3 (1,81) (50,8) (96,0) (57,2) (36,6) (26,9) (0,6) 1/2 165.9 1.32 4.00 2.25 0.88 1.25 1.1 (0,738) (33,5) (101,6) (57,2) (22,4) (31,8) (0,5) 1-1/2 1.900 259.9 1.93 4.00 2.25 1.43 1.25 3.1 (DN40) (48,3) 3/4 (1,156) (49,0) (101,6) (57,2) (36,3) (31,8) (0,5) 1 406.9 2.11 4.00 2.25 1.55 1.25 1.3 (1,81) (53,6) (101,6) (57,2) (39,4) (31,8) (0,6) . 1/2 165.9 1.56 4.46 2.25 1.12 1.50 1.3 (0,738) (39,6) (113,3) (57,2) (28,4) (38,1) (0,6) 2 2.375 3/4 259.9 2.17 4.46 2.25 1.67 1.50 1.5 (DN50) (60,3) (1,156) (55,1) (113,3) (57,2) (42,4) (38,1) (0,7) 1 406.9 2.35 4.46 2.50 1.79 1.50 1.5 (1,81) (60,0) (113,3) (63,5) (45,5) (38,1) (0,7) 1/2 165.9 2.00 5.12 2.25 1.56 1.69 1.5 (0,738) (50,8) (130,0) (57,2) (39,6) (42,9) (0,7) 2-1/2 2.875 259.9 2.50 5.12 2.25 2.00 1.69 1.8 (DN65) (73,0) 3/4 (1,156) (63,5) (130,0) (57,2) (50,8) (42,9) (0,8) 1 406.9 2.70 5.12 2.50 2.14 1.69 1.8 (1,81) (68,6) (130,0) (63,5) (54,4) (42,9) (0,8) 1/2 165.9 2.00 5.12 2.25 1.56 1.82 1.5 (0,738) (50,8) (130,0) (57,2) (39,6) (46,2) (0,7) 76.1 mm 3.000 259.9 2.50 5.12 2.25 2.00 1.82 1.8 (DN65) (76,1) 3/4 (1,156) (63,5) (130,0) (57,2) (50,8) (46,2) (0,8) 1 406.9 2.75 5.12 2.50 2.19 1.82 1.8 (1,81) (69,9) (130,0) (63,5) (55,6) _ (46,2) (0,8) $Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Always confirm compatibility by contacting TYCO Fire Protection Products for details. FIGURE 1 FIGURE 522 SPRINKLER OUTLET NOMINAL DIMENSIONS TFP1865 Page 3 of 4 Step 1 Hole Diameter* Nominal Run Size Nominal Branch Size Tolerance+ ANSI Inches ANSI Inches(DN) Inches Inches (DN) (mm) (mm) #` - 1/2(DN15) 1 3/4(DN20) (DN25) ' ' 1 (DN25) 3/8(DN10) 1-1/4 1/2(DN15)1`y+'. (DN32) 3/4(DN20) 0.94 ' 1 (DN25) (24'0) 1/2(DN15) 0.02 Ste�,2 1-1/2 3/4(DN20) (0,5) (DN40) i. 1 (DN25) .K•% j 1/2(DN15) 2 3/4(DN20) (DN50) 1 (DN25) 1.38(34,9) •,, 1/2(DN15) •'�:-,,. ,, 76.1 mm 3/4(DN20) 0.94(24,0) (DN65) 1 (DN25) 1.38(34,9) 'Proper hole preparation is required for effective sealing and performance.Check the pipe seal surface within 5/8 inches(15.88 mm)of the hole to be certain it is free from conditions that would affect proper gasket sealing.Remove any sharp Step 3 ,A, or rough edges from the hole or upper housing contact area that might affect as- sembly,proper seating of the locating collar,or flow from the outlet.Check gasket , grade to be certain it is suitable for the service.The use of threaded products other than steel pipe,such as dry pendants,etc.may not be compatible with the 1:,1;i1,3:' female threaded outlet on the Mechanical Tee.Always confirm compatibility by - • contacting GRINNELL Products. TABLE A r , FIGURE 522 SPRINKLER OUTLET•iY∎ PIPE HOLE FABRICATION DIMENSIONS Step 3.With one nut and bolt removed Installation and the other nut threaded out flush The GRINNELL G-FIRE Figure 522 with the end of the screw, swing the Sprinkler Outlets are to be installed in housing over the hole in the pipe. Step 4 OUTLET accordance with this section. Step 4.Verify that the housing outlet _ GASKET Step 1.Select hole size from Table A. locating collar is positioned in the hole. LOCATING _ The hole must be drilled on the pipe Insert the other bolt into the housing COLLAR —''% center-line.Remove any sharp or rough and rotate the nuts clockwise until fin- HOUSING edges from the hole or upper housing ��� � g ger tight.Verify that the bolt heads are contact area.The gasket-seating sur- fully seated in the housing. PIPE face on the pipe should be examined PIPE HOLE to verify all loose debris, dirt, chips, Step 5.Alternate when tightening nuts - (TABLE A) paint and any other foreign material until properly torqued to between 15 such as grease are removed. 20 ft.-Ibs. (20-27 Nm)with even gaps between the bolt pads. Uneven tight- Verify that the gasket grade is correct ening can cause the gasket to pinch Step 5 � for the application intended. Refer to or bind.Over torquing can damage the f is Technical Data Sheet TFP1895 for ad- product or thin wall pipe and will not '-- ditional gasket information. increase sealing efficiency. Step 2.Check for proper gasket posi- tioning in the housing.The alignment t - - i tabs on the gasket should fit into the q 1 recesses of the housing.Check sealing r rj '. ; surface for cuts or imperfections that would affect sealing. For Wet Based ' 1-,.1,',. ' , ' applications, no lubricant is required. f ` f I,-, ,'' ,. When used for Dry Pipe and Freezer applications,use a petroleum-free sili- con based lubricant. TFP1865 Page 4 of 4 Ordering Procedure Grinnell Mechanical Products, valves, accessories and other products are available globally through a network of distribution centers. For the near- est distributor, visit www.grinnell.com. When placing an order,indicate the full product name. Figure 522 Sprinkler Outlet Specify the following: • Quantity • Run Size x Outlet Size • ISO 7/1 or NPT Outlet Threads • Finish GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. Vico - tqco I Fire & Building Products Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 730 Mechanical Tees - Threaded / Grooved General Protective Coatings: Limited •Non-lead orange paint Description •Fire brigade red(optional)non-lead paint Warranty •Hot dipped galvanized conforming to ASTM Products manufactured by Tyco Fire Products are ® co A-153 warranted solely to the original Buyer for ten(10) 1 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile = years against defects in material and workmanship "., when paid for and properly installed and maintained 110,000 psi/758,422 kPa) } � Metric conforming to ASTM F568M under normal use and service. This warranty will Gasket: (specify when ordering) expire ten(10)years from date of shipment by Tyco I �. `'%J" Fire Products. No warranty is given for products or — ,: ' • Grade"E"EPDM,green color code `r �' (See Data Sheet TFP1895 for aid in selecting components manufactured by companies not PCB L 1- -t affiliated by ownership with Tyco FireProductsorfor L.rI,D VdS % Jt proper gasket) products and components which have been subject � : 11 t+ to misuse,improper installation,corrosion,orwhich -' Ordering have not been installed, maintained,modified or See Fire Protection Submittal Sheet for Pressure repaired in accordance with applicable Standards of Rating and Listing/Approval Information Procedure the National Fire Protection Association (NFPA), The Figure 730 Mechanical Tees may be used for When placing an order,indicate the full product and/orthe standards ofanyotherAuthorities Having any tee connection where a threaded or grooved name.Please specify the quantity,figure number, Jurisdiction.Materials found by Tyco Fire Products outlet is needed. They may be converted into a type of gasket,Grade"E"EPDM,and size. to be defective shall be either repaired or replaced,at cross when necessary. Grinnell Grooved Piping Products, valves, Tyco Fire Products'sole option.Tyco Fire Products WARNING accessories and other products are available neither assumes, nor authorizes any person to The Figure 730 Mechanical Tee described herein throughout the U.S.,Canada,and internationally, assumeforit,anyotherobligation in connectionwith must be installed and maintained in compliance through a network of distribution centers. You the sale of products or parts of products. Tyco Fire with this document,as well as with the applicable may write directly or call 215-362-0700 for the Productsshallnotbe responsibleforsprinklersystem standards of the National Fire Protection distributor nearest you. design errors or inaccurateorincompleteinformation Association, in addition to the standards of any supplied by Buyer or Buyer's representatives. other authorities having jurisdiction.Failure to do Care and IN NO EVENT SHALL TYCO FIRE PRODUCTS BE so may impair the performance of this device. LIABLE,IN CONTRACT,TORT,STRICT LIABILITY The owner is responsible for maintaining their Maintenance OR UNDER ANY OTHER LEGAL THEORY, FOR fire protection system and devices in proper INCIDENTAL, INDIRECT, SPECIAL OR operating condition.The installing contractor or The owner is responsible for the inspection, CONSEQUENTIALDAMAGES,INCLUDINGBUTNOT • sprinklermanufacturershouldbe contacted with testing,and maintenance of their fire protection LIMITED TO LABOR CHARGES,REGARDLESS OF any questions. system and devices in accordance with the WHETHERTYCOFIREPRODUCTSWASINFORMED applicable standards of the National Fire Protection ABOUT THE POSSIBILITY OF SUCH DAMAGES, Association (e.g., NFPA 25), in addition to the AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' Technical standards of any authority having jurisdiction. LIABILITY EXCEED AN AMOUNT EQUAL TO THE Data The installing contractor or product manufacturer SALES PRICE. should be contacted relative to any questions. THE FOREGOING WARRANTY IS MADE IN LIEU OF Figure: 730 Any impairment must be immediately corrected. ANY AND ALL OTHER WARRANTIES EXPRESS OR Outlet:Threaded or Grooved It is recommended that automatic sprinkler IMPLIED. INCLUDING WARRANTIES OF Approvals: UL, FM, ULC, VdS, and LPCB; systems be inspected,tested,and maintained by MERCHANTABILITY AND FITNESS FOR A See Fire Protection Submittal Sheet for exact a qualified Inspection Service. PARTICULAR PURPOSE. Listing/Approval information. Housing: Ductile iron conforming to ASTM A-536,Grade 65-45-12 Page 1 of 4 September 2004 TFP1860 Page 2 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Threaded) Jill /ill 1111 _I/ill FAO WA A r 0 .roil .. A TAKEOUT �� �� TAKEOUT �air II, s J 1' 1 , • • *girl E MI t lamiN A,J `�� `+ TAKEOUT .,;;/r A Figure 730 Mechanical Outlet Tee Figure 730 Mechanical Outlet Cross (Threaded) (Threaded) Nom.Size Hole Dia.$ Nominal Dimensions Bolt Tee Cross Hole Max. A B C D E Net Wt. Net Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Size"" Lbs. Lbs. mm mm mm mm mm mm mm Dia.x Lg. Kg. Kg. 2"x'/z",'/,", 1" 1.50 1.63 2.62 4.88 3.07 2.12 1.59 a/a"X 2'/4" 2.2 2.6 38.1 41.3 66.5 124.0 78.0 53.8 40.4 M10 x 57 1.0 1.2 2"x 1'/4" 1.75 1.88 2.78 4.88 3.32 1.93 1.59 3/s"x 2'/4" 2.5 3.3 44.5 47.6 70.6 124.0 84.3 49.0 40.4 M10 x 57 1.1 1.5 2"x 1'/2" 1.75 1.88 2.75 4.88 3.32 1.93 1.59 3/e"x 2'/,° 2.5 3.7 44.5 47.6 69.9 124.0 84.3 49.0 40.4 M10 x 57 1.1 1.7 2'/2"x'/z 3/a", 1" 1.50 1.63 2.88 5.25 3.07 2.38 1.81 3/e"x 2Y," 2.7 3.1 38.1 41.3 73.2 133.4 78.0 60.5 46.0 M10 x 57 1.2 1.4 2'/z"x 1'/." 2.00 2.13 3.00 5.25 3.56 2.19 1.81 3/e"x 2'/," 3.1 3.9 50.8 54.0 76.2 133.4 90.4 55.6 46.0 M10 x 57 1.4 1.8 2'/2°x 1'/2" 2.00 2.13 3.07 5.25 3.59 2.17 1.81 3/s"x 2'/," 3.3 4.3 50.8 54.0 78.0 133.4 91.2 55.1 46.0 M10 x 57 1.5 1.9 2'/2"x 2" 2.00 2.13 3.19 5.25 4.00 2.44 1.81 3/8"x 21/4" 3.5 4.4 50.8 54.0 81.0 133.4 101.6 62.0 46.0 M10 x 57 1.6 2.0 76.1mm x'/z",3/4", 1" 1.50 1.63 2.94 5.62 3.07 2.44 1.87 M10 x 57 2.7 3.1 38.1 41.3 74.5 142.7 78.0 62.0 47.5 1.2 1.4 76.1mm x 1'/," 2.00 2.13 3.06 5.62 3.56 2.25 1.87 M10 x 57 3.1 3.9 50.8 54.0 77.7 142.7 90.4 57.2 47.5 1.4 1.8 76.imm x 1'/2" 2.00 2.13 3.13 5.62 3.56 2.25 1.87 M10 x 57 3.3 5.1 50.8 54.0 79.5 142.7 90.4 57.2 47.5 1.5 2.3 76.imm x 2" 2.50 2.63 3.25 5.62 4.00 2.50 1.87 M10 x 57 4.1 5.9 63.5 66.7 82.6 142.7 101.6 63.5 47.5 1.9 2.7 3"x'/z 3/, 1" 1.50 1.63 3.19 6.13 3.07 2.56 2.21 /z"x 3" 3.7 4.5 38.1 41.3 81.0 155.7 78.0 65.0 56.1 M12 x 76 1.7 2.0 3"x 1'/4" 1.75' 1.88 3.34 6.13 3.32 2.50 2.21 V2"x 3" 3.9 4.9 44.5 47.6 84.8 155.7 84.3 63.5 56.1 M12 x 76 1.8 2.2 3"x 1'/2" 2.00 2.13 3.38 6.13 3.56 2.48 2.21 '/z"x 3" 4.2 5.5 50.8 54.0 85.9 155.7 90.4 63.0 56.1 M12 x 76 1.9 2.5 3"x 2" 2.50 2.63 3.50 6.13 4.09 2.75 2.21 1/2"x 3" 4.7 6.5 63.5 66.7 88.9 155.7 103.9 69.9 56.1 M12 x 76 2.1 2.9 4"x'/i',3/4", 1" 1.50 1.63 3.69 7.13 3.07 3.06 2.78 '/z"x 3" 5.5 7.1 38.1 41.3 93.7 181.1 78.0 77.7 70.6 M12 x 76 2.5 3.2 4"x 1'/4" 1.75" 1.88 3.92 7.13 3.32 3.00 2.78 V2"x 3" 5.5 7.1 44.5 47.6 99.6 181.1 84.3 76.2 70.6 M12 x 76 2.5 3.2 4"x 1'/2" 2.00 2.13 4.00 7.13 3.56 2.98 2.78 '/z"x 3" 5.5 7.1 50.8 54.0 101.6 181.1 90.4 75.7 70.6 M12 x 76 2.5 3.2 4"x 2" 2.50 2.63 4.00 7.13 4.06 3.25 2.78 '/z"x 3" 6.0 8.1 63.5 66.7 101.6 181.1 103.1 82.6 70.6 M12 x 76 2.7 3.7 4"x 2'/2" 2.75 2.88 4.00 7.13 4.38 3.12 2.78 '/z"x 3" 6.0 8.1 69.9 73.0 101.6 181.1 111.3 79.2 70.6 M12 x 76 2.7 3.7 4"X 76.1mm 2.75 2.88 4.00 7.13 4.38 3.12 2.78 M12 x 76 6.0 8.1 69.9 73.0 101.6 181.1 111.3 79.2 70.6 2.7 3.7 4"x 3" 3.50 3.63 4.13 7.13 5.13 3.31 2.78 '/z"x 3" 7.0 13.5 88.9 92.1 104.9 181.1 130.3 84.1 70.6 M12 x 76 3.2 6.1 $ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within`/o of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area,that might affect assembly,proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses,ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe,such as dry pendents,etc.may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. Gold color coded metric bolt sizes are available upon request. Note:Outlet threads conforming to ISO 7.1 are available,contact Tyco Fire Products for details. Page 3 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Threaded) g O 8 1;;1 1111 1;;1 1111 A fir A TAKEOUT TAKEOUT �rhE �I � Ifli d wi TAR TAKEOUT �„� L. ,I1 1I1 Figure 730 Mechanical Outlet Tee Figure 730 Mechanical Outlet Cross (Threaded) (Threaded) Nom. Size Hole Dia.$ Nominal Dimensions Bolt Tee Cross Hole Max. A B C D E Size" Net Wt. Net Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Dia.x Lg. Lbs. Lbs. mm mm mm mm mm mm mm Kg. Kg. 2.00 2.13 4.63 8.13 3.56 4.00 3.37 5/5"X 43/4" 6.5 7.7 5"x 1'/2" 50.8 54.0 117.6 206.5 90.4 101.6 85.6 M16 x 121 2.9 3.5 2.50 2.63 4.63 8.13 4.06 3.88 3.37 5/a"x 43/4" 7.1 8.1 5"x 2" 63.5 66.7 117.6 206.5 103.1 98.6 85.6 M16 x 121 3.2 3.7 2.75 2.88 4.75 8.13 4.38 3.88 3.37 a/e"x 43/4" 7.3 8.7 5"x 2'/2" 69.9 73.0 120.7 206.5 111.3 98.6 85.6 M16 x 121 3.3 3.9 2.75 2.88 4.75 8.13 4.38 3.88 3.37 M 16 x 121 7.3 8.7 5"x 76.1 mm 69.9 73.0 120.7 206.5 111.3 98.6 85.6 3.3 3.9 3.50 3.63 5.00 8.13 5.13 4.06 3.37 5/a"x 43/4" 7.6 14.7 5"x 3" 88.9 92.1 127.0 206.5 130.3 103.1 85.6 M16 x 121 3.4 6.7 2.00 2.13 5.13 9.25 3.56 4.25 3.90 6.9 7.9 165.1 mm x 11/4" M16 x 121 50.8 54.0 130.3 235.0 90.4 108.0 99.1 3.1 3.6 2.00 2.13 5.13 9.25 3.56 4.04 3.90 M 16 x 121 7.4 8.9 165.1mm x 1'/2" 50.8 54.0 130.3 235.0 90.4 102.6 99.1 3.4 4.0 2.50 2.63 5.13 9.25 4.06 4.31 3.90 M16 x 121 7.5 8.9 165.t mm x 2" 63.5 66.7 130.3 235.0 103.1 109.5 99.1 3.4 4.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 11.1 165.1mm x 2'/2° M16 x 121 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 M 16 x 121 7.5 11.1 165.1mm x 76.1mm 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 3.50 3.63 5.50 9.25 5.13 4.37 3.90 M16 x 121 9.5 14.1 165.1 mm x 3" 88.9 92.1 139.7 235.0 130.3 111.0 99.1 4.3 6.4 4.50 4.63 5.38 9.25 6.13 4.56 3.90 M 16 x 121 10.0 20.1 165.1x4" 114.3 117.5 136.7 235.0 155.7 115.8 99.1 4.5 9.1 2.00 2.13 5.13 9.25 3.56 4.25 3.90 s/a"x 43/4" 6.9 7.9 6"x 11/4" 50.8 54.0 130.3 235.0 90.4 108.0 99.1 M16 x 121 3.1 3.6 2.00 2.13 5.13 9.25 3.56 4.04 3.90 5/e"x 43/4" 7.4 8.9 6"x 1'/2" 50.8 54.0 130.3 235.0 90.4 102.6 99.1 M16 x 121 3.4 4.0 2.50 2.63 5.13 9.25 4.06 4.31 3.90 5/9"x 43/4" 7.5 8.9 6"x 2" 63.5 66.7 130.3 235.0 103.1 109.5 99.1 M16 x 121 3.4 4.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 5/8"x 43/4" 7.5 11.1 6"x 2'/2" 69.9 73.0 130.3 235.0 111.3 106.2 99.1 M16 x 121 3.4 .5.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 M16 x 121 7.5 11.1 6"x 76.t""' 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 3.50 3.63 5.50 9.25 5.13 4.37 3.90 5/0"x 43/4" 9.5 14.1 6"x 3" 88.9 92.1 139.7 235.0 130.3 111.0 99.1 M16 x 121 4.3 6.4 4.50 4.63 5.38 9.25 6.13 4.56 3.90 5/a"x 43/4" 10.0 20.1 6"x 4" 114.3 117.5 136.7 235.0 155.7 115.8 99.1 M16 121 4.5 9.1 2.75 2.88 6.25 12.50 4.38 5.12 4.90 3/4"x 43/4" 10.2 12.1 8 x 2'/2" 69.9 73.0 158.8 317.5 111.3 130.0 124.5 M20 121 4.6 5.5 2.75 2.88 6.25 12.50 4.38 5.12 4.90 M20 x 121 10.2 12.1 8"x 76.1, 69.9 73.0 158.8 317.5 111.3 130.0 124.5 4.6 5.5 3.50 3.63 6.50 12.50 5.13 5.37 4.90 3/4' x 43/4" 12.5 15.1 8"x 3" 88.9 92.1 165.1 317.5 130.3 136.4 124.5 M20 x 121 5.7 6.8 4.50 4.63 6.38 12.50 6.13 5.56 4.90 3/4"x 43/4" 12.5 21.1 8"x 4" 114.3 117.5 162.1 317.5 155.7 141.2 124.5 M20 x 121 5.7 9.6 # Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within"I.of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area,that might affect assembly,proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses,ensure double outlet holes are aligned on opposite sides of the pipe.The use of threaded products other than steel pipe,such as dry pendents,etc.may not be compatible with the female threaded outlet on the Mechanical Tee.Always confirm compatibility by contacting Tyco Fire Products. Gold color coded metric boll sizes are available upon request. Note:Outlet threads conforming to ISO 7-1 are available,contact Tyco Fire Products for details. Page 4 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Grooved) B C 8 C MIMI M� -- MIN 40-1114, A iv II•lAia:a A IIVIIIIII 1111111". it ""/AI Mal% 1. %�=M!► II '�w�j. EI Ito�Win E Nil ��.� A /+� Figure 730 Mechanical Outlet Figure 730 Mechanical Outlet Grooved Tee Grooved Cross Nominal Hole Dia.$ Nominal Dimensions Tee Cross Nominal Hole 0ia.$ Nominal Dimensions Tee Cross Size Hole Max A B C E Size' Net Wt. Net Wt. Hole Max. A B C E Ben, Net Wt. Net Wt. Run x Inches Inches Inches Inches Inches Inches Lbs. Lbs. Run x Inches Inches Inches Inches Inches Inches Lbs. Lbs. Branch mm mm mm mm mm mm Dia.x Lg. Kg. Kg. Branch mm mm mm mm mm mm Dia.x Lg. Kg. Kg. 7 x 1'/: 1.75 1.88 2.78 4.88 3.32 1.59 31i x 2Y; 2.5 3.3 5'x 76.1 2.75 2.88 4.75 8.13 4.38 3.37 Mt6 x 121 7.3 8.7 44.5 47.6 70.6 1240 84.3 40.4 M10x57 1.1 1.5 69.9 73.0 120.7 206.5 111.3 85.6 3.3 3.9 2'X 1'/a' 1.75 1.88 2.62 4.88 3.32 1.59 3/i x 2'/i 2.5 3.7 5'X 3' 3.50 3.63 5.00 8.13 5.13 3.37 Vi x 43/1 7.6 14.7 44.5 47.6 66.5 124.0 84.3 404 M10x57 1.1 1.7 88.9 92.1 127.0 206.5 130.3 85.6 M16x 121 3.4 6.7 2'/i x 1'/; 2.00 2.13 3.00 5.25 3.56 1.81 3/i x 2'/i 3.1 3.9 165.1...x 1'/: 2.00 2.13 5.13 9.25 3.56 3.90 M16 x 121 6.9 7.9 50.8 54.0 76.2 133.4 90.4 46.0 M10x57 1.4 1.8 50.8 54.0 130.3 235.0 90.4 99.1 3.1 3.6 2'/z X 1'/i 2.00 2.13 3.07 5.25 3.59 1.81 3/i x 2'/: 3.3 4.3 165.imm X 1'/{ 2.00 2.13 5.13 9.25 3.56 3.90 M16 x121 7.4 8.9 50.8 54.0 78.0 133.4 91.2 46.0 M10x57 1.5 1.9 50.8 54.0 130.3 235.0 90.4 99.1 3.4 4.0 2.00 2.13 3.19 5.25 4.00 1.81 3/i x 2'/; 3.5 4.4 2.50 2.63 5.13 9.25 4.06 3.90 7.5 8.9 2'/i x 7 50.8 54.0 81.0 133.4 101.6 46.0 M10 x 57 1.6 20 165.1 x 7 63.5 66.7 130.3 235.0 103.1 99.1 M16 x 121 14 4.0 76.1x 1'/; 2.00 2.13 3.06 5.62 3.56 1.87 M10 x 57 3.1 3.9 165.1..x 2'/i 2.75 2.88 5.13 9.25 4.38 3.90 M1 fi x 121 7.5 11.1 50.8 54.0 77.7 1427 90.4 475 1.4 1.8 69.9 73.0 130.3 235.0 111.3 99.1 14 5.0 2.00 2.13 3.13 5.62 3.56 1.87 3.3 5.1 2.75 2.88 5.13 9.25 4.38 3.90 7.5 11.1 76.1 x1'/s' 50.8 54.0 79.5 142.7 904 47.5 M10x57 1.5 2.3 165.immx76.tmm 69.9 73.0 130.3 235.0 111.3 99.1 M16x121 3.4 5.0 2.50 2.63 3.25 5.62 4.00 1.87 4.1 5.9r 3.50 3.63 5.50 9.25 5.13 3.90 9.5 14.1 76.1 x 2 63 5 667 82.6 142.7 101.6 47.5 M10 x 57 1.9 2.7 165.1 x 3' 88.9 92.1 139.7 235.0 130.3 99.1 M16 x121 43 6.4 3'x1'/; 1.75' 1.88 3.34 6.13 3.32 2.21 1/2'x3' 3.9 4.9 165.1m.x4' 4.50 4.63 5.38 9.25 6.13 3.90 M16x121 10.0 20.1 44.5 47.6 84.8 1557 84.3 56.1 M12x76 1.8 2.2 114.3 117.5 136.7 235.0 155.7 99.1 45 91 3'x 1'/2" 2.00 2.13 3.38 6.13 3.56 2.21 'h'x 3' 4.2 5.5 6'x 11/4' 2.00 2.13 5.13 9.25 3.56 3.90 W.x 43/i 6.9 7.9 50.8 54.0 85.9 155.7 90.4 56.1 M12x76 1.9 2.5 50.8 54.0 130.3 235.0 90.4 99.1 M16x 121 3.1 3.6 3'x 2' 2.50 2.63 ' 3.50 6.13 4.09 2.21 1/2'X 3' 4.7 6.5 6'X 1'/i 2.00 2.13 5.13 9.25 3.56 3.90 5/5"x 43/1 7.4 8.9 63.5 66.7 88.9 155.7 103.9 56.1 M12x76 21 29 50.8 54.0 130.3 235.0 90.4 99.1 M16x 121 3.4 4.0 4'x 1'/; 1.75" 1.88 3.92 7.13 3.32 2.78 '1i x 3' 5.5 7.1 6 x 2 2.50 2.63 5.13 9.25 4.06 3.90 5/i x 431: 7.5 8.9 44.5 47.6 99.6 181.1 84.3 70.6 M12x76 25 3.2 63.5 66.7 130.3 235.0 103.1 99.1 M16x 121 3.4 4.0 4'x 1'Ji 2.00 2.13 4.00 7.13 3.56 2.78 '/z x 3' 5.5 7.1 6'x 2'/i 2.75 2.88 5.13 9.25 4.38 3.90 5/i x 43/: 7.5 11.1 50.8 54.0 101.6 181.1 90.4 70.6 M12x76 25 3.2 69.9 73.0 130.3 235.0 111.3 99.1 M16x 121 3.4 5.0 2.50 2.63 4.00 7.13 4.06 2.78 '/2'x 3' 6.0 8.1 2.75 2.88 5.13 9.25 4.38 3.90 7.5 11.1 4'x2' 63.5 66.7 101.6 181.1 103.1 70.6 M12x76 2.7 3.7 6'x76.1mn 699 73.0 130.3 2350 111.3 99.1 M16x121 14 5.0 4'X 21/2' 2.75 2.88 4.00 7.13 4.38 2.78 1/2'x 3' 6.0 8.1 6`x 3' 3.50 3.63 5.50 9.25 5.13 3.90 5/5'x 43/1 9.5 14.1 699 73.0 101.6 181.1 111.3 706 M12x76 2.7 3.7 88.9 92.1 1397 235.0 130.3 99.1 M16x 121 4.3 6.4 4'x 76.15m 2.75 2.88 4.00 7.13 4.38 2.78 M12 x 76 6.0 8.1 6'X 4' 4.50 4.63 5.38 9.25 6.13 3.90 5/i x 4'/i 10.0 20.1 69.9 73.0 101.6 181.1 111.3 70.6 27 3.7 114.3 117.5 136.7 235.0 155.7 99.1 M16x 121 4.5 9.1 4'x 3' 3.50 3.63 4.13 7.13 5.13 2.78 '/i x 3' 7.0 13.5 8'x 2'/2' 2.75 2.88 6.25 12.50 4.38 4.90 3/:x 43/: 10.2 12.1 88.9 92.1 104.9 181.1 130.3 70.6 M12x76 3.2 6.1 69.9 73.0 158.8 3175 111.3 124.5 M20x 121 4.6 5.5 5'x 11/2' 2.00' 2.13 4.63 8.13 3.56 3.37 3/4'x 43/1 6.5 7.7 8'x 76.1.. 2.75 2.88 6.25 12.50 4.38 4.90 M20 x 121 10.2 12.1 ° 50.8 54.0 117.6 206.5 90.4 85.6 M16x 121 2.9 3.5 69.9 73.0 158.8 317.5 111.3 124.5 46 5.5 5'x 2 2.50 2.63 4.63 8.13 4.06 3.37 VI x 43/i 7.1 8.1 8.x 3' 3.50 3.63 6.50 12.50 5.13 4.90 3/:x 4311 12.5 15.1 63.5 66.7 117.6 206.5 103.1 85.6 M16x 121 3.2 3.7 88.9 92.1 165.1 317.5 130.3 124.5 M20 121 57 6.8 5'x 21/2' 2.75 2.88 4.75 8.13 4.38 3.37 5/i x 43/1 7.3 8.7 8'x 4' 4.50 4.63 6.38 12.50 6.13 4.90 3/4'x 43/1 12.5 21.1 69.9 73.0 120.7 206.5 111.3 85.6 M16x 121 3.3 3.9 114.3 117.5 1621 3175 155.7 124.5 M20 121 5.7 9.6 $ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within rh"of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area,that might affect assembly,proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses,ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe,such as dry pendents,etc.may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. -' Gold color coded metric bolt sizes are available upon request. 411111N General Notes:It is the Designer's responsibility to select products suitable for the intended service and to ensure / ISO MN that pressure ratings and performance data is not exceeded. Always read and understand the installation .?., 9001 ',.ter instructions(IH-1000). Never remove any piping component or correct or modify any piping deficiencies without ��\It�� first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19946 Printed U.S.A. Vito Fire & Building Products Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Material: Limited Cast:Figures:201,210,219,250,260,501,510, Description 519,510DE,501S,510S and 519S- Warranty See Fire Protection Ductile iron conforming to ASTM A-536, Products manufactured by Tyco Fire Products are LP8 Vd S Submittal Sheet for Grade 65-45-12 warranted solely to the original Buyer for ten(10) Pressure Rating and Fabricated Steel: Figures 391, 392, 393, 312, years against defects in material and workmanship ® Listing/Approval Information 313,321,327,341 and 350-Carbon Steel, (Sizes 1'/4' 6'are Schedule 40); when paid for and properly installed and maintained ® (Sizes 8'-12'are Schedule 30), under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco conforming to ASTM A-53 Grade B The grooved fittings provide an economical Protective Coatings: Fire Products.manufactured warranty is given oor products or and efficient method of changing direction, •Non-lead orange paint components mrshipwthTyco by companies not adding an outlet, reducing, or capping •Fire brigade red(optional)non-lead paint affiliated byowoms on nts hich have been subject g g' pp g g ( p ) p products and components which have been subject grooved piping systems.Grooved fittings •Hot dipped galvanized conforming to ASTM to misuse,improper installation,corrosion,or which are available in durable ductile iron or A-153 have not been installed, maintained, modified or fabricated steel as indicated. repaired in accordance with applicable Standards of Note: Figure 510S and 519S fittings are Ordering the National Fire Protection Association (NFPA), special short radius fittings with smaller and/orthestandards of any otherAuthorities Having center to end dimensions than standard Procedure Jurisdiction. Materials found by Tyco Fire Products grooved fittings. Depending on the size and When placing an order,indicate the full product to be defective shall be either repaired or replaced,at coupling used,there may be interferences at name.Please specifythe quantity,figure number, Tyco Fire Products'sole option.Tyco Fire Products the bolt pads that require repositioning of the wall thickness,and size. neither assumes, nor authorizes any person to coupling orientation. The use of flange Grinnell Grooved Piping Products, valves, assumeforit,anyotherobligationinconnectionwith adapters is not recommended with Figures accessories and other products are available the sale of products or parts of products.Tyco Fire 510S and 519S fittings. Contact Tyco Fire throughout the U.S.,Canada,and internationally, Productsshallnotberesponsibleforsprinklersystem Products for details. through a network of distribution centers.You designerrorsorinaccurateorincompleteinformation WARNING may write directly or call 215-362-0700 for the supplied by Buyer or Buyer's representatives. The Fittings described herein must be installed distributor nearest you. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE and maintained in compliance with this document LIABLE,IN CONTRACT,TORT,STRICT LIABILITY as well as with the applicable standards of the Care and OR UNDER ANY OTHER LEGAL THEORY, FOR National fire Protection Association,in addition • INCIDENTAL, INDIRECT, SPECIAL OR to the standards of any other authorities having IVlalntenance CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT jurisdiction. Failure to do so may impair the The owner is responsible for the inspection, LIMITED TO LABOR CHARGES,REGARDLESS OF performance of this device. testing,and maintenance of their fire protection WHETHERTYCOFIREPROOUCTSWASINFORMED The owner is responsible for maintaining their system and devices in accordance with the ABOUT THE POSSIBILITY OF SUCH DAMAGES, fire protection system and devices in proper applicable standards of the National Fire Protection AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' operating condition.The installing contractor or Association (e.g., NFPA 25), in addition to the LIABILITY EXCEED AN AMOUNT EQUAL TO THE sprinkler manufacturer should be contacted with standards of any authority having jurisdiction. SALES PRICE. any questions. The installing contractor or product manufacturer THE FOREGOING WARRANTY IS MADE IN LIEU OF should be contacted relative to any questions. ANY AND ALL OTHER WARRANTIES EXPRESS OR Technical Any impairment must be immediately corrected. IMPLIED. INCLUDING WARRANTIES OF It is recommended that automatic sprinkler MERCHANTABILITY AND FITNESS FOR A Data systems be inspected,tested,and maintained by PARTICULAR PURPOSE. Approvals: a qualified Inspection Service. UL,FM,ULC,VdS,and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Page 1 of 6 MARCH 2011 TFP1810 Page 2 of 6 TFP1810 Figures 201 , 210, 219, and 260 CtoE Figure 201 Figure 210 Figure 219 Figure 260$ 45°Elbow 90°Elbow Tee End Cap I I Nominal C to E Appx.Wt. C to E Appx.Wt. C to E Appx.Wt. E to E Appx.Wt. Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. c t} E c to Size E mm Kg. mm Kg. mm Kg. mm Kg. -�C to E 1 I /a° 1.75 0.9 2.75 1.0 2.75 1.4 0.88 0.4 L v 1 1 44.5 0.4 69.9 0.5 69.9 0.6 22.4 0.2 1.75 1.1 2.75 1.2 2.75 1.8 0.88 0.6 Figure 201 1'/2 44.5 0.5 69.9 0.5 69.9 0.8 22.4 0.3 Figure 210 2.00 1.8 3.25 • 2.0 3.25 2.7 0.88 0.9 2" 50.8 0.8 82.6 0.9 82.6 1.2 22.4 0.4 2'/2° 2.25 2.2 3.75 3.0 3.75 5.8 0.88 0.9 i--CloE-I EtoE1 57.2 1.0 95.3 1.4 95.3 2.6 22.4 0.4 76.1 mm 2.25 2.2 3.75 3.0 3.75 5.8 0.94 1.1 57.2 1.0 95.3 1.4 95.3 2.6 23.9 0.5 s C 2.50 3.5 4.25 4.5 4.25 7.0 0.88 1.1 3 63.5 1.6 108.0 2.0 108.0 3.2 22.4 0.5 P C to E L 2.88 5.5 4.75 8.5 4.75 11.5 108.0mm 73.0 2.5 120.7 3.9 120.7 5.2 i■ltttttttm-I Figure 260 4„ 3.00 5.2 5.00 8.5 5.00 11.8 1.00 2.6 76.2 2.4 1270 3.9 127.0 5.4 25.4 1.2 Figure 219 133.0mm 3.25 7.7 5.25 11.3 5.25 10.6 82.6 3.5 133.4 5.1 133.4 4.8 139.7mm 3.25 7.7 5.50 11.3 5.50 15.3 0.92 4.7 82.6 3.5 139.7 5.1 139.7 6.9 23.4 2.1 3.25 8.5 5.50 13.5 5.50 17.0 1.00 5.0 Friction Resistance' S 82.6 3.9 139.7 6.1 139.7 77 25.4 2.3 (Expressed as Equivalent Straight Pipe) 3.50 12.0 6.00 14.6 6.00 13.9 Elbow Tee 159.Omm 88.9 5.4 152.4 6.6 152.4 6.3 Size 90° 45° Branch Run 165.1mm 3.50 12.0 6.50 18.5 6.50 26.0 1.00 7.5 Inches Feet Feet Feet Feet 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 mm Meters Meters Meters Meters 3.50 12.0 6.50 18.5 6.50 26.0 1.00 7.5 11/4 1.9 1.0 4.8 1.9 6" 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 42.4 0.6 0.3 1.5 0.6 4.25 23.0 7.75 36.5 7.75 45.0 11/2 2.3 1.2 5.8 2.3 216.3mm 108.0 10.4 196.9 16.6 196.9 20.4 48.3 0.7 0.4 1.8 0.7 4.25 23.0 7.75 36.5 7.75 45.0 1.19 12.8 2 3.2 1.6 8.0 3.2 8 108.0 10.4 196.9 16.6 196.9 20.4 30.2 5.8 60.3 1.0 0.5 2.5 1.0 4.75 31.0 9.00 60.0 9.00 72.1 1.25 20.0 21/2 3.9 2.0 9.8 3.9 10 120.7 14.1 228.6 27.2 228.6 32.7 31.8 9.1 73.0 1.2 0.6 3.0 1.2 5.25 40.0 10.00 67.0 10.00 92.5 1.25 36.0 4.1 2.1 10.3 4.1 12 133.4 18.1 254.0 30.4 254.0 42.0 31.8 16.3 76.1 mm 1.2 0.6 3.1 1.2 - 3 4.9 2.4 12.2 4.9 # -Available with tapped plugs,contact Tyco Fire 8 Building Products. 88.9 1.5 0.7 3.7 1.5 108.0 6.5 3.3 16.3 6.5 2.0 1.0 5.0 2.0 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 133.0 8.0 4.0 20.0 8.0 2.4 1.2 6.1 2.4 139.7mm 8.0 4.1 20.0 8.0 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 2.5 159.0 9.5 4.8 23.8 9.5 . 2.9 1.4 7.2 2.9 165.1 9'5 4.8 23.8 9.5 m m 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 7.6 3.0 216.3,,,,, 4.0 6.6 32.8 13.1 4.0 2.0 10.0 4.0 8 13.1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 10 16.5 8.3 41.3 16.5 _ 273.0 5.0 2.5 12.6 5.0 12 19.9 9.9 49.7 19.9 323.4 6.1 3.0 15.1 6.1 For reducing tees and branches,use the value that is corrosponding to the branch size.Example:for 8'x 8'x 2'tee,the branch value 2'is 8.0 feet. ' Friction resistance for all elbows and tees except Figures 510S and 5198. Page 3 of 6 TFP1810 Figures 501 , 510, 519 and 51 ODE ° CtoE 0111 I-CtoE-I I}III i III ai\\\hi a ., 111 -----;---- Al II �_F I CWE CtoE L� I1 CtoE f3 ! • Figure 501 Figure 510 Figure 519 Figure 510DE • Figure 501 Figure 510 Figure 519 Figure 510DE 45°Elbow 90°Elbow Tee 90°Drain Elbow Nominal C to E Appx.Wt. C to E Appx.Wt. C to E Appx.Wt. C to E A B Appx.Wt. Size Inches Lbs. Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. mm Kg. mm Kg. mm Kg. mm mm mm Kg. 1'/4" 1.75 0.9 2.75 1.0 2.75 1.4 - - - - 44.5 0.4 69.9 0.5 69.9 0.6 1'/i 1.75 1.1 2.75 1.2 2.75 1.8 44.5 0.5 69.9 0.5 69.9 0.8 2« 2.00 1.8 3.25 2.0 3.25 2.7 - - - - 50.8 0.8 82.6 0.9 82.6 1.2 2'/z" 2.25 2.2 3.75 3.0 3.75 5.8 3.75 2.00 ' 2.75 2.7 57.2 1.0 95.3 1.4 95.3 2.6 95.3 50.8 69.9 1.2 3, 2.50 3.5 4.25 4.5 4.25 7.0 4.25 2.34 2.75 3.7 63.5 1.6 108.0 2.0 108.0 3.2 108.0 59.4 69.9 1.7 4, 3.00 5.2 5.00 8.5 5.00 11.8 5.00 2.85 2.75 7.0 76.2 2.4 127.0 3.9 127.0 5.4 127.0 72.4 69.9 3.2 5« 3.25 8.5 5.50 13.5 5.50 17.0 5.50 3.38 2.75 13.0 82.6 3.9 139.7 6.1 139.7 7.7 139.7 85.9 69.9 5.9 6« 3.50 12.0 6.50 18.5 6.50 26.0 6.50 3.92 2.75 13.4 88.9 5.4 165.1 8.4 165.1 11.8 165.1 99.6 69.9 6.1 8« 4.25 23.0 7.75 36.5 7.75 45.0 7.75 4.95 2.75 26.3 108.0 10.4 196.9 16.6 196.9 20.4 196.9 125.7 69.9 11.9 Figures 501S, 510S and 519S CtoE al 1--CtoE--I 1 II I1IIII 1 & CtoE CtoE L. . tea; ! f C to E i-CtoE .r,..___l_ • Figure 501S Figure 510S° Figure 519S* Figure 501S Figure 510S Figure 519S Friction Resistance 501S,510S&519S 45°Elbow 90°Elbow Tee (Expressed as Equivalent Straight Pipe) Nominal C to E Appx Wt. C to E Appx.Wt. C to E Appx.Wt. Elbow Tee Size Inches Lbs. Inches Lbs. Inches Lbs. Size 90° 45° Branch Run mm Kg. mm Kg. mm Kg. Inches Feet Feet Feet Feet 2., 2.00 1.8 2.75 1.5 2.75 2.1 - mm Meters Meters Meters Meters 50.8 0.8 69.9 0.7 69.9 1.0 2 3.2 1.6 8.0 3.2 2'/z" 2.25 2.2 3.00 2.2 3.00 3.0 60.3 1.0 0.5 2.5 1.0 57.2 1.0 76.2 1.0 76.2 1.4 2'/z 3.9 2.0 9.8 3.9 76.1 mm 2.25 2.2 3.00 2.3 3.00 3.1 - 73.0 1.2 0.6 3.0 1.2 57.2 1.0 76.2 1.0 76.2 1.4 4.1 2.1 10.3 4.1 3„ 2.50 3.5 3.38 3.0 3.38 4.1 76.1 1.2 0.6 3.1 1.2 63.5 1.6 85.9 1.3 85.9 1.9 3 4.9 2.4 12.2 4.9 4« 3.00 5.2 4.00 5.6 4.00 7.7 88.9 1.5 0.7 3.7 1.5 76.2 2.4 101.6 2.6 101.6 3.5 4 6.5 3.3 16.3 6.5 139.7 3.25 7.7 4.88 8.6 4.88 12.0 - 114.3 2.0 1.0 5.0 2.0 82.6 3.5 124.0 3.9 124.0 5.4 8.0 4.1 20.0 8.0 5« 3.25 8.5 4.88 8.8 4.88 12.0 139.7.. 2.4 1.3 6.1 2.4 82.6 3.9 124.0 3.9 124.0 5.4 5 8.2 4.1 20.5 8.2 165.1.. 3.50 12.0 5.50 11.00 5.50 15.0 - 141.3 2.5 1.3 6.3 2.5 88.9 5.4 139.7 5.0 139.7 6.8 9.5 4.8 23.8 9.5 6., 3.50 12.0 5.50 11.2 5.50 15.2 165.1.., 2.9 1.4 7.2 2.9 88.9 5.4 139.7 5.1 139.7 6.9 4.25 23.0 6.88 23.4 6.88 31.2 6 9.9 5.0 24.8 9.9 8" 168.3 3.0 1.5 7.6 3.0 108.0 10.4 174.8 10.6 174.8 14.2 8 13.1 6.6 32.8 13.1 'Note:Figure 5105 and 519S fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings.Depending on the site and coupling used,there may he interferences 219.1 4.0 2.0 10.0 4.0 at the holt pads which requires repositioning of the coupling orientation.The use of flange adapters Is not recommended with Figures 510S and 519S fittings.Contact Tyco Fire Products for details. Page 4 of 6 TFP1810 Figures 250 and 350 • Figures 250 and 350 Concentric Reducer-Groove x Groove Nominal E to E Appx.Wt. Nominal E to E Appx.Wt. Nominal E to E Appx.Wt. I-EtoE--1 Size Inches Lbs. Size Inches Lbs. Size Inches Lbs. III Inches mm Kg. Inches mm mm Kg. Inches mm Kg. 2.50 1.0 3.50 4.2 4.00 5.8 '2X11/4'a 63.5 0.5 '139.7x3 88.9 1.9 �6%5 101.6 2.6 '2 x 1'/z 2.50 1.3 "139.7..x 4 3.50 4.4 8 x 2 5.00 12.2 63.5 0.6 88.9 2.0 127.0 5.5 Figure '2'/zx2 2.50 . 1.2 5x1Y� 3.50 4.6 8x2'/z 5.00 12.1 . 9 63.5 0.5 88.9 2.1 127.0 5.5 Cast 2.50 1.5 3.50 4.6 5.00 12.0 '76.1..x11/2 63.5 0.7 5 x 2 88.9 2.1 8 x 3 127.0 5.5 2.50 1.6 3.50 4.5 5.00 11.9 I--Eta E-1 '76.1..x2 63.5 0.8 5x2'1/2 z 88.9 2.0 8x4 127.0 5.4 3x1'1/4 r 2.50 1.3 5 x 3 3.50 4.4 8 x 5 5.00 11.3 63.5 0.6 88.9 2.0 127.0 5.1 1111111 3x1'1/2 z 63.5 0.6 '5x4 88.9 2.0 8 x 6 127.0 14.9 '3X2 2.50 1.3 '165.1..X3 4.00 5.5 10X4 6.00 21.9 Figure 350 63.5 0.6 101.6 2.5 152.4 10.0 Fabricated '3 x 2,/z 3.00 1.5 "165.imm x 4 4.00 6.0 10 x 5 6.00 21.6 Sizes 3"to 6" 76.2 0.7 101.6 2.7 152.4 9.8 '3 x 76.1.. 3.00 2.0 '165.1..x 139.7." 4.00 5.6 10 x 6 6.00 21.1 76.2 0.9 101.6 2.5 152.4 9.6 '----E to E-1 3.00 2.2 4.00 6.0 6.00 19.5 4x1'/. '6x2 10x8 I 76.2 1.0 101.6 2.7 152.4 8.9 �11 3.00 2.3 4.00 6.0 7.00 28.0 4 x 11/2 76.2 1.0 6 x 2'/z 101.6 2.7 12 x 4 177.8 12.7 7.00 30.0 '4x2 3.00 2.3 •6x76.1.. 4.00 6.0 12X6 76.2 1.0 101.6 2.7 177.8 13.6 Figure 350 3.00 2.3 4.00 6.0 7.00 28.0 Fabricated '4 x 21/2 76.2 1.0 6 x 3 101.6 2.7 12 x 8 177.8 12.7 Sizes 8"to 12" 3.00 3.2 4.00 5.9 7.00 33.0 '4x76.1.. 76.2 1.5 "6x4 101.6 2.7 12%10 177.8 15.0 4x3 3.00 2.6 •6x139.7.. 4.00 6.3 76.2 1.2 101.6 _ 2.9 Note:Sizes marked with an asterisk(')are only available in Figure 250 Cast. Sizes without an asterisk are only available in Figure 350 Fabricated. ADA CAP° Pine Nominal Dimensions - Size Outlet OAD. TakBeout Center to EDnd WI.t Inches NPT' Inches Inches Inches Inches Lbs. D •i Inches mm mm mm mm Kg. /z 1.25 1.75 1.89 0.77 31.8 44.5 48.0 0.3 '�� 1'/z 3/4 1.900 1.25 1.75 1.89 0.77 c 48.3 31.8 44.5 48.0 0.3 B 1.37 2.00 2.02 0.88 i 1 1 34.8 50.8 51.3 0.4 A - ----------- ._._._._.J._._. . ,/z 1.25 1.75 1.89 0.92 - I i 31.8 44.5 48.0 0.4 L 2 ,/� 2.375 1.25 1.75 1.89 0.92 60.3 31.8 44.5 48.0 0.4 1 1.37 2.00 2.02 1.06 34.8 50.8 51.3 0.5 1/2 1.47 1.97 1.89 1.28 37.3 50.0 48.0 0.6 2'/2 3/4 2.875 1.47 1.97 1.89 1.28 73.0 37.3 50.0 48.0 0.6 1 1.37 2.00 2.02 1.50 34.8 50.8 51.3 0.7 I30-7 threaded outlets are available upon request. Page 5 of 6 TFP1810 Figures 391 , 392, 393, 312 and 313 E to E--id Figures 391, Figure 312 Figure 313 -. 392 and 393 22'6i Elbow 11'/a°Elbow Adapter Nipples Figure Nominal E to E Appx.Wt. C to E Appx.Wt. C to E Appx.Wt. - `-----`•-. 391 Inches Lbs. Inches Lbs. Inches Lbs. Size mm Kg. mm Kg. mm Kg. - Fo-E to E_ 1'/a„ 101.6 0.8 44.5 0.4 3 .1 0.4 I 101.6 0.4 44.5 0.2 35.1 0.2 1,62 4.00 0.9 1.75 0.5 1.38 05 Figure 101.6 . 0.4 44.5 0.2 35.1 0.2 392 - 2„ 4.00 1.2 1.88 0.6 1.38 0.6 101.6 0.5 47.8 0.3 35.1 0.3 2/z„ 4.00 1.9 2.00 0.7 1.50 1.1 h E to E--. "1 -- -- 101.6 0.9 50.8 0.3 38.1 0.5 3„ 4.00 2.5 2.25 1.4 1.50 1.2 101.6 1.1 57.2 0.6 38.1 0.5 Figure 6.00 5.5 2.63 2.4 1.75 2.2 393 4„ 1524 2.5 66.8 1.1 44.5 1.0 2.00 3.3 5„ 6.00 7.4 2.88 4.1 152.4 3.4 73.2 1.9 50.8 1.5 C to E 6„ 6.00 9.5 3.13 5.6 2.00 4.6 152.4 4.3 79.5 2.5 50.8 2.1 Figure 8„ 6.00 14.2 3.88 11.1 2.00 8.7 312 152.4 6.4 98.6 5.0 50.8 3.9 c to E 8.00 27.0 4.38 14.0 2.13 9.1 1 10" 203.2 12.2 J J.3 6.4 54.1 4.1 C to E . 12" 8.00 33.0 4.88 22.0 2.25 16.7 Figure 203.2 15.0 124.0 10.0 57.2 7.6 C to E 313 Figures 327 and 341 ,.._c to E- Figure 341 Figure 327 150 lbs. Cross Flange Adapter Nominal C to E Appx.Wt. E to E Appx.Wt. Size nches Lbs. Inches Lbs. mm kg. mm kg. _... r 2.75 2.0 4.00 2.8 1'/." Il 69.6 0.9 101.6 1.3 C to E 11/20 2.75 2.2 4.00 3.2 69.9 3.25 2.0 2.7 101.6_ 1.5 4.0 5.2 2, Figure 327 82.6 1.2 101.6 2.4 2'/z° 3.75 5.0 4.00 8.0 95.3 2.3 101.6 3.6 3„ 4.25 7.1 4.00 10.2 108.0 3.2 101.6 4.6 4„ 5.00 11.9 6.00 17.2•I' I ' 127.0 5.4 152.4 7.8 Ijl I II 5 5.50 17.1 6.00 21.4 E to E 139.7 7.8 1524 9.7 I 6.50 27.5 6.00 26.0 t j t l 6" 165.1 12.5 1524 11.8 j 8„ 7.75 47.0 6.00 38.4 Figure 341 196.9 21.3 152.4 17.4 10" 9.00 68.0 8.00 65.0 228.6 30.8 203.2 29.5 12" 10.00 107.0 8.00 91.0 254.0 48.5 203.2 41.3 Page 6 of 6 TFP1810 Figure 321 • _ I--c to E--I Figure 321 Reducing Tee I Nominal C to E Appx.Wt. Nominal C to E Appx.Wt. __�. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. j 1'1/2 zx11x1% 3.25 2.0 6x6x4 6.50 26.6 c to E 82.6 0.9 165.1 12.1 I � 3.25 2.7 6.50 27.0 1 2x2x1/z 82.6 1.2 sx6x5 165.1 12.2 • Figure 321 - 2'1/2 zx2'1/2 zx1'1/4< 3.75 4.2 8 x 8 x 2 7.75 36.2 95.3 1.9 196.9 16.4 2'1/2 zx2'1/2 zx 1'/z 3.75 4.2 8x8x3 7.75 36.5 95.3 1.9 196.9 16.6 2%x2'1/2 zx2 3.75 4.3 8x8x4 7.75 36.6 95.3 2.0 196.9 16.6 3x3x1'1/2 z 4.25 5.3 8x8x5 7.75 36.8 108.0 24 196.9 16.7 4.25 5.5 7.75 37.0 3x3x2 108.0 2.5 8x8x6 196.9 16.8 3x3x2' 4.25 5.8 10x10x2 9.00 57.1 108.0 2.6 228.6 25.9 4x4x1'1/4 a 5.00 9.8 10x10x3 9.00 57.4 127.0 4.4 228.6 26.0 4x4x1'1/2 z 5.00 9.9 10x10x4 9.00 57.6 127.0 4.5 228.6 26.1 4x4x2 5.00 10.1 10x10x5 9.00 57.8 127.0 4.6 228.6 26.2 4x4x2Yz 5.00 10.3 10x10x6 9.00 58.0 127.0 4.7 228.6 26.3 4x4x3 5.00 10.5 10x10x8 9.00 58.4 127.0 4.8 228.6 26.5 5 x 5 x 2 5.50 14.5 12 x 12 x 3 10.00 80.2 139.7 6.6 254.0 36.4 - 5 x 5 x 2% 5.50 14.8 12 x 12 x 4 10.00 80.5 139.7 6.7 254.0 36.5 5x5x3 5.50 15.2 12 x 12 x 5 10.00 80.7 139.7 6.9 254.0 36.6 5 x 5 x 4 5.50 15.8 12 x 12 x 6 10.00 80.9 139.7 7.2 254.0 36.7 6 x 6 x 2 6.50 26.5 12 x 12 x 8 10.00 91.4 165.1 11.9 254.0 41.5 6x6x21/2 6.50 26.5 12 x 12 x 10 10.00 91.8 165.1 12.0 254.0 41.6 6x6x3 6.50 26.5 165.1 12.0 4Ifilig , General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure SO that pressure ratings and performance data is not exceeded.Always read and understand the installation instructions 001 (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first \% depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19946 Printed U.S.A. - Lilco Fire & Building Products Technical Services:Tel: (800) 381-9312/Fax: (800)791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented General Housing: Ductile iron conforming to should be contacted relative to any questions. ASTM A-536,Grade 65-45-12 Any impairment must be immediately corrected. Description Protective Coatings: It is recommended that automatic sprinkler •Non-lead orange paint systems be inspected,tested,and maintained by ' p( --_ •Fire brigade red(optional)non-lead paint a qualified Inspection Service. MB' cB, •Hot dipped galvanized conforming to ASTM A-153 Limited VdS - Bolt/Nuts: Track Head Bolts - conforming to warranty ASTM A-183, Zinc Plated, (Min. Tensile = ® 415 110,000 psi/758,422 kPa) Products manufactured by Tyco Fire Products are Metric conforming to ASTM F568M warranted solely to the original Buyer for ten(10)years See Fire Protection Gasket: (specify when ordering) againstdefectsinmaterialandworkmanshipwhen paid Submittal Sheet for • Grade"A"EPDMA violet color code forand properly installed and maintained under normal Pressure Rating and Listing/Approval Information ambient to+150°F(+66°C)forfire protection useand service.This warrantywill expireten(10)years The Figure 772RigidCouplingprovidesarigidjointby systems. Not recommended for hot water from date of shipment by Tyco Fire Products. No firmly gripping along the circumference of the pipe systems. warranty is given for products or components • Tri-seal(Grade"E"EPDM),green color code manufactured bycompaniesnotaffiliated byownership grooves.Rigid couplings are preferred for dry pipe for use in dry pipe or freezer systems. withTyco FireProducts orfor productsand components and freezer applications.Figure 772 Rigid Couplings . Prelubricated(Grade"A"EPDMA) whichhavebeensubjecttomisuse,improperinstallation, are a proven dependable method of joining pipe and (See Data Sheet TFP1895 for aid in selecting corrosion,orwhichhavenotbeeninstalled,maintained, arean economical alternative to welding,threading or proper gasket) modified or repaired in accordance with applicable using flanges.It is capable of pressures up to 500 psig Standards of the National Fire Protection Association (3447 kPa)depending on pipe size and wall thickness (NFPA),and/or the standards of any other Authorities when used in fire protection services. ordering Having Jurisdiction. Materials found by Tyco Fire Rigid Couplings are recommended for dry pipe and procedure Products to be defective shall be either repaired or freezer applications. replaced,at Tyco Fire Products'sole option.Tyco Fire WARNING When placing an order,indicate the full product Products neither assumes,nor authorizes any person The Figure 772 Rigid Coupling described herein name.Please specify the quantity,figure number, to assume for it,any other obligation in connection with must be installed and maintained in compliance with type of gasket,Grade"A"EPDMA,Prelubricated the sale of products or parts of products. Tyco Fire thisdocument,asw ellaswiththeapplicablestandards (Grade"A"EPDMA)or Grade"E"EPDM Tri-Seal, Products shall not be responsible for sprinkler system of the National Fire Protection Association,inaddition and size. design errors or inaccurate or incomplete information to the standards of any other authorities having GrinnellGroovedPiping Products,valves,accessories supplied by Buyer or Buyer's representatives. jurisdiction. Failure to do so may impair the and other products are available throughout the IN NO EVENT SHALL TYCO FIRE PRODUCTS BE performance of this device. U.S.,Canada,and internationally,through a network LIABLE,IN CONTRACT,TORT,STRICT LIABILITY OR The owner is responsible for maintaining their fire of distribution centers.You may write directly or call UNDERANYOTHERLEGALTHEORY,FORINCIDENTAL protection system and devices in proper operating 215-362-0700 for the distributor nearest you. INDIRECT,SPECIAL OR CONSEOUENTIALDAMAGES, condition. The installing contractor or sprinkler INCLUDING BUT NOTLIMITEDTOLABORCHARGES, manufacturershouldbecontactedwithanyquestions. Care and REGARDLESS OF WHETHER TYCO FIRE PRODUCTS Maintenance INFORMED ABOUT THE POSSIBILITY OF SUCH Technical DAMAGES,AND IN NO EVENT SHALL TYCO FIRE The owner is responsible for the inspection, PRODUCTS'LIABILITYEXCEEDANAMOUNTEOUAL _ Data testing,and maintenance of their fire protection TO THE SALES PRICE. Figure: 772 system and devices in accordance with the THE FOREGOING WARRANTY IS MADE IN LIEU OF Sizes: l''/d' 12" applicable standards of the National Fire Protection ANY AND ALL OTHER WARRANTIES EXPRESS OR Approvals: UL, FM, ULC, VdS, and LPCB; Association (e.g., NFPA 25), in addition to the IMPLIED, INCLUDING WARRANTIES OF See Fire Protection Submittal Sheet for exact standards of any authority having jurisdiction. MERCHANTABILITY AND FITNESS FOR A Listing/Approval information. The installing contractor or product manufacturer PARTICULAR PURPOSE. Page 1 of 2 July 2004 TFP1850 Page 2 of 2 TFP1850 Figure 772 Grooved Coupling . B I c`1 1•��•r A 'I n 'L'J wI'1 emu' 11111 Pipe Max.'$ Max.t Max.t Nominal Dimensions Net Bolt O.D. End Gap Pressure End Load A B C Wt. Size" Size Inches Inches psi Lbs. Inches Inches Inches Lbs. mm mm kPa N mm mm mm Dia.x Lg. Kg 1,1/4�" 1.660 0.06 300 649 2.75 4.38 1.81 '/8"x 2'/a" 1.0 42.4 1.5 2,068 2,887 69.9 111.3 46.0 M10 x 57 0.5 1'/2 1.900 0.08 500 1,417 3.00 4.62 1.81 3/8"x 2'/4" 1.0 48.3 2.0 3,447 6,303 76.2 117.3 46.0 M10 x 57 0.5 2" 2.375 0.13 500 2,214 3.41 5.12 1.88 3/4"x 21/4" 1.5 60.3 3.3 3,447 9,848 86.6 130.0 47.8 M10 x 57 0.7 2W 2.875 0.13 500 3,244 3.91 5.63 1.88 3/8"x 21/4" 2.5 73.0 3.3 3,447 14,430 99.3 143.0 47.8 M10x57 1.1 76.1 mm 3.000 0.13 300 2,120 4.19 5.72 2.00 M10 x 57 2.6 76.1 3.3 2,068 9,430 106.4 145.3 50.8 1.2 3,. 3.500 0.13 500 4,808 4.63 6.25 1.88 %"x 21/4" 2.6 88.9 3.3 3,447 21,387 117.6 158.8 47.8 M10 x 57 1.2 4,. 4.500 0.19 500 7,948 5.81 7.50 1.97 3/s"x 21/4" 3.5 114.3 4.8 3,447 35,353 147.6 190.5 50.0 M10 x 57 1.6 139.7r8. 5,500 0.19 300 7,127 7.02 9.72 2.06 M16 x 83 7.5 139.7 4.8 2,068 31,701 178.3 246.9 52.3 3.4 5,. 5.563 0.19 300 7,288 7.09 9.71 2.04 5/s"x 31/4" 7.5 141.3 4.8 2,068 32,417 180.1 246.6 51.8 M16 x 83 3.4 165.18,8, 6,500 0.19 300 9,950 8.09 10.53 2.13 M16 x 83 7.6 165.1 4.8 2,068 44,258 205.5 267.5 54.1 3.4 6., 6.625 0.19 400 13,782 8.09 10.53 2.13 3/4"x 31" 7.6 168.3 4.8 2,758 61,302 205.5 267.5 54.1 M16 x 83 3.4 8,. 8.625 0.19 450 26,278 10.56 13.56 2.62 3/4"x 4W 18.0 219.1 4.8 3,103 116,885 268.2 344.4 66.5 M20 x 121 8.2 10" 10.750 0.13 250 22,679 12.84 16.41 2.62 1"x 61/2" 24.6 273.0 3.3 1,724 100,876 326.1 416.8 66.5 M24 x 165 11.2 12" 12.750 0.13 250 31,903 15.41 18.84 2.62 1"x 6'/2" 42.0 323.9 3.3 1,724 141,905 391.4 478.5 66.5 M24 x 165 19.1 ' Maximum available gap between pipe ends.Minimum gap=0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe.Pressure ratings and end loads may differ on other pipe materials and/or wall thickness.Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. "Gold color coded metric bolt sizes are available upon request. $ Max End Gap is for cut grooved standard weight pipe.Values for roll grooved pipe will be 1/2 that of cut grooved. _ Figure 772 Rigid Couplings have an Anti-Rotation Feature of"gripping teeth"along the coupling keys in sizes 1'/4"-4",which make the Figure 772 perfectly suited for"arm over"installations where the likelihood of rotation is greatest.This feature may eliminate the need of extra hangers to support the arm over due to increased rigidity and gripping force saving time and cost. General Notes:It is the Designer's responsibility to select products suitable for the intended service and to ensure , ISO = that pressure ratings and performance data is not exceeded. Always read and understand the installation .., 9001 rs. instructions(IH-1000). Never remove any piping component or correct or modify any piping deficiencies without vow first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19946 Printed U.S.A. . tqco `ire & Building Products Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 705 Flexible Coupling General Protective Coatings: It is recommended that automatic sprinkler •Non-lead orange paint systems be inspected,tested,and maintained by Description •Fire brigade red(optional)non-lead paint a qualified Inspection Service. •Hot dipped galvanized conforming to ASTM A-153 Limited LP� �p -, Bolt/Nuts: Track Head Bolts - conforming to CB _ ASTM A-183, Zinc Plated, (Min. Tensile = Warranty 110,000 psi/158,422 kPa) Products manufactured by Tyco Fire Products are VdS E Metric-conforming to ASTM F568M warranted solely to the original Buyer for ten(10) Gasket: (specify when ordering) years against defects in material and workmanship ® V see Fire Protection • Grade"A"EPDMA violet color code when paid for and properly installed and maintained ® submittal sheet for ambientto+150°F(+66°C)forf ire protection under normal use and service. This warranty will Pressure Rating and systems. Not recommended for hot water expire ten(10)years from date of shipment by Tyco Listing/Approval Information systems. Fire Products. No warranty is given for products or The Figure 705 Flexible Coupling is capable of ' Tri seal(Grade"E"EPDM),greencolorcode• components manufactured by companies not pressures up to 300 psig(2068 kPa)depending • Prelubricated(Grade"A"EPDMA) affiliated by ownership with Tyco Fire Productsorfor on pipe size and wall thickness when used in fire (See Data Sheet TFP1895 for aid in selecting products and components which have been subject protection services. It provides a dependable proper gasket) to misuse,improper installation,corrosion,orwhich method of joining pipe and is suitable for use in have not been installed, maintained, modified or a variety of applications. Ordering repaired in accordance with applicable Standards of Rigid Couplings are recommended for dry pipe Procedure the National Fire Protection Association (NFPA), and freezer applications. and/or the standards of any other Authorities Having WARNING When placing an order,indicate the full product Jurisdiction. Materials found by Tyco Fire Products The Figure 705 Flexible Coupling described herein name.Please specify the quantity,figure number, to be defective shall be either repaired or replaced,at must be installed and maintained in compliance type of gasket,Grade"A"EPDMA,Prelubricated Tyco Fire Products'sole option.Tyco Fire Products with this document,as well as with the applicable (Grade"A"EPDMA)or Grade"E"EPDM Tri-Seal, neither assumes, nor authorizes any person to standards of the National Fire Protection and size. assume for it,any other obligation in connection with Association, in addition to the standards of any Grinnell Grooved Piping Products, valves, the sale of products or parts of products. Tyco Fire other authorities having jurisdiction.Failure to do accessories and other products are available Productsshallnotberesponsibleforsprinklersystem so may impair the performance of this device. throughout the U.S.,Canada,and internationally, design errors _ The owner is responsible for maintaining their through a network of distribution centers.You supplied by Buyer or Buyer's representatives. fire protection system and devices in proper may write directly or call 215-362-0700 for the IN NO EVENT SHALL TYCO FIRE PRODUCTS BE operating condition.The installing contractor or distributor nearest you. LIABLE,IN CONTRACT,TORT,STRICT LIABILITY - sprinkler manufacturershould be contacted with OR UNDER ANY OTHER LEGAL THEORY, FOR any questions. Care and INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUTNOT Technical Maintenance LIMITED TO LABOR CHARGES,REGARDLESS OF The owner is responsible for the inspection, WHETHERTYCOFIREPRODUCTSWASINFORMED Data testing,and maintenance of their fire protection ABOUT THE POSSIBILITY OF SUCH DAMAGES, system and devices in accordance with the AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' Figure: 705 LIABILITY EXCEED AN AMOUNT EQUAL TO THE Sizes:VA"-12" applicable standards of the National Fire Protection SALES PRICE. Approvals: UL, FM, ULC, VdS, and LPCB; Association (e.g., NFPA 25), in addition to the THE FOREGOING WARRANTYIS MADE IN LIEU OF See Fire Protection Submittal Sheet for exact standards of any authority having jurisdiction. ANY AND ALL OTHER WARRANTIES EXPRESS OR Listing/Approval information. The installing contractor or product manufacturer Housing: Ductile iron conforming to should be contacted relative to any questions. IMPLIED, INCLUDING WARRANTIES OF ASTM A-536,Grade 65-45-12 Any impairment must be immediately corrected. MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 2 July 2004 TFP1820 Page 2 of 2 TFP1820 Figure 705 Grooved Coupling B lit i■r 'i !,i AM bud mrk ;rim 7/1 11 - ... Orli Pipe Max.'$ Max.t Max.t Nominal Dimensions Deflection$ Bolt Net 0.D. End Gap Pressure End load A B C Inches/ Wt. Size Inches Inches psi Lbs. Inches Inches Inches Per Foot Size` Lbs. Coupling Dia.x Lg. mm mm kPa N mm mm mm mm/m Kg. 1.660 0.13 300 649 2.56 4.19 1.81 0.90 3/5"x 2'/4" 1.5 1/4 42.4 3.3 2,068 2,887 65.0 106.4 46.0 4 19 75.0 M10 x 57 0.7 1.900 0.13 300 850 2.75 4.44 1.81 0.79 3/e"x 2'/4" 1.6 1/z' 48.3 3.3 2,068 3,781 69.9 112.8 46.0 3 -46' 65.8 M10 x 57 0.7 2.375 0.13 300 1,328 3.25 4.88 1.88 0.63 3/8"x 2'/4" 1.7 2' 60.3 3.3 2,068 5,907 82.6 124.0 47.8 3" 1 52.5 M10 x 57 0.8 2.875 0.13 300 1,947 3.69 5.50 1.88 0.52 3/e"x 21/4" 2.0 21/2" 73.0 3.3 2,068 8,660 93.7 139.7 47.8 2 -29' 43.3 M10 x 57 0.9 3.000 0.13 300 2,120 4.00 5.75 1.88 2° 23' 0.50 M12 x 76 3.1 76.1mm 76.1 3.3 2,068 9,430 101.6 146.1 47.8 41.7 1.4 3.500 0.13 300 2,885 4.38 6.50 1.88 0.43 1/2"x 3" 3.0 3 88.9 3.3 2,068 12,832 111.3 165.1 47.8 2" 3' 35.8 M12 x 76 1.4 4.250 0.25 300 4,256 5.50 7.50 2.06 0.70 4.2 108.0mm 108.0 6.4 2,068 18,931 139.7 190.5 52.3 3" 22 58.3 M12 x 76 1.9 . 4.500 0.25 300 4,769 5.69 7.75 2.06 0.67 '/2"x 3" 4.0 4 114.3 6.4 2,068 21,213 144.5 196.9 52.3 3° 11' 55.8 M12 x 76 1.8 133.0mm 5.250 0.25 300 6,494 6.56 9.50 2.06 Zo 44, 0.56 M16 X 83 7.2 133.0 6.4 2,068 28,885 166.6 241.3 52.3 46.7 3.3 5.500 0.25 300 7,127 6.81 9.75 2.06 0.56 7.2 139.7mm 139.7 6.4 2,068 31,701 173.0 247.7 52.3 2" 36 46.7 M16 x 83 3.3 5.563 0.25 300 7,288 6.88 9.75 2.06 0.54 5/e"x 3'/+" 7.0 _5 141.3 6.4 2,068 32,417_174.8 247.7 52.3 2°-35' 45.0 M16 x 83 3.2 6.250 0.25 300 9,204 7.56 10.31 2.06 2° 17' 0.48 M16 x 83 7.4 159.0mm 159.0 6.4 2,068 40,939 192.0 261.9 52.3 40.0 3.4 165.1 mm 6.500 0.25 300 9,950 7.75 10.69 2.06 2° 12' 0.46 M16 x 83 7.1 165.1 6.4 2,068 44,258 196.9 271.5 52.3 38.3 3.2 6.625 0.25 300 10,336 7.94 10.69 2.06 0.45 5/e"x 3'/4" 7.1 6 168.3 6.4 2,068 45,975 201.7 271.5 52.3 2° 10' 37.5 M16 x 83 3.2 216.3mm 8.500 0.25 300 17,024 10.07 13.50 2.31 1 -40' M20X121 216.3 6.4 2,068 75,723 255.8 342.9 58.7 29.2 5.6 8„ 8.625 0.25 300 17,519 10.19 13.56 2.50 1° 40, 0.35 3/4"X 43/4" 14.5 - 219.1 6.4 2,068 77,925 258.8 344.4 63.5 29.2 M20 x 121 6.6 10.750 0.25 250 22,679 12.69 16.38 2.63 0.28 1"x 61/2" 28.0 10" 273.0 6.4 1,724 100,876 322.3 416.1 66.8 1" 20' 23.3 M24 x 165 12.7 - 12" 12.750 0.25 250 31,903 14.94 18.88 2.63 1, 7, 0.23 1"x 6'/2" 36.5 323.9 6.4 1,724 141,905 379.5 479.6 66.8 19.2 M24 x 165 16.6 • Maximum available gap between pipe ends.Minimum gap=0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe.Pressure ratings and end loads may differ on other pipe materials and/or wall thickness.Contact Tyco Fire Products for details.See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. "Gold color coded metric bolt sizes are available upon request. $ Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be'/z that of cut grooved. General Notes:It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO • that pressure ratings and performance data is not exceeded. Always read and understand the installation t 9001 rf, instructions(IH-1000). Never remove any piping component or correct or modify any piping deficiencies without ` 1Wj. first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19946 Printed U.S.A. WELD-MISER' TEE-LETS Welded Outlet Fittings /Xruvii_Star- p. A d,,,,,,,,,,,,,,,-„,., MERIT. I Typo A rr� 7` t; Female Thread y r --a u r -. _ WELD.MISERTM TEE-LET° WELD-MISER"'TEE-LET° DIMENSIONS& PART NUMBERS DIMENSIONS & PART NUMBERS :1 ti:-s.,e ;:r!e• t-,,.s h.'.MI HN••ne! 4v.+ tiA. YurU "iJ Fm t4 i'U l:r.•Gtt Fta%rlu {1s!rf H<a:a 4.^.g'� D,:evra D +' DJW HreCer lr. Dameur 2 + I B ( D ftd NJ-bet A B �` D ld tack • 1 •• . l � . 1 I • .. - taw.oser•t 022:02• roe to to seed c.F.AFp.p.- . Al r.:am-.r.t.•2.:I.•Lon e....Ka Rr AK. ..d . I . 1"-' ,/iN L Mcrt Tao Lot,.S Drop Arpplos WWW.anvilst fGO1 WELD-MISER' TEE-LETS welded Outlet Fittings /Xl i..Star MP•a.. C....a/M.,..'..,m•J _ Tyype Et Typo C MERIT Maio Thread Cut Groovo St.ndard Woighl Standard Weight A ,. £ I C C . r ,- F r - F • ` -- 0 ► , 41 - 0 a. e WELD-MISER"TEE-LET• -DIMENSIONS (NOMINAL SIZES 1"THRU 2"3 4c'.Nu:i Gen ^n^:!C.t'n .:I r.:... le- 1..L: .• C::.e C:.--.r.e •_ i _ I • I I I I I .. I I I I 1 • I I I • L;• • - - I 1 I I I I • _ I I _ ,I - i i 1 I I . .. I I 1 • - I I I . • 1 - - I L Mar:T..Lets ant.....AocM.d leer s.:.Y,-,n..dvad..cant rndshop.on a gaan T.rl..s mod.6444 p.4.o*on the 1W L dad toads Ado r.2bGd on/..s.oud Mod.w•. ....tad ca dr ea.g a sigh,gap a4 opp.ea.no4.FF •...1 app.ar ewg.M k..g ud J...M.t..e!Ito Mad..For..o-p..a 1••2•2 •Tow to..s a 1•..d.4 ia.ng r•.o..bo*. d a a p..4.oy on Ph.2•hod.•um l f.d.—b:te...g a-.•?op o4r2 n.k ghd.ol a.,.Iwo d d..2'.••o.F o p4.4.d 4 n np.+d to!o 2.•food..pp.•••••••0 1••2-.•1• 4• 1.4...td b.ads.d S.ca otdauxa.-.entriayed anerkva ...uy and p.v.de for gnaw M.61.., Monk'Too-Lots&Drop N,pp lo tvvnN.anvilsttlr com (=).Al.MnL i..fStar- WELD-MISER'" TEE-LE7'� /1.ntv Welded Outlet Fittings • - Typo B Typo C Typpo C/B M IT Male Thread Cut Groovo Roll Groovo SI..nd.rd Weight St.lndlydl•/oight Schedule 10 ;11 C C • t•Bl /1 BA s'_.0 B �_.p NELD.MISER—TEE-LET•Y-DIMENSIONS (NOMINAL SIZES 2'/2.'THRU S") fJ K:nrol Pule men- 0::4, 'r'.1 Neon:•F FwM ihnf 041 Goa. lr.+.xl Ca'd 441.. Cv etle h W.Wt. Cr St! k}.10 A C kroduf !c:!�Jr Psmeht S•:rlr:l S�.i!e RI Wek 1: Woyr r r,^r' I . rs I '1?r1'' II i, ltif: I I . • I I I ! • I . • I I r I 1 I 1 I • • New Solna era rramfoeaxof+o f.•a:ran.aa.fMe die caraa,red:hops ca a gaga T..-L..o moth k•fo of peaked?eo fM fan/sad hoods s.:. !•rofol4d m M coon Foods fa.. 'naiad as N FArg a 1.14.sop J opprooR•• -..•..I cocoa okog fM b+gw,drol ca.atro of to Mod.+Fa..a-o s.0 1'a 2•2.!'avW,o o I•c-SS frnn3,norvfao,rd b fa psf.o en*a 2'heads um 1 sof..I,L I.o•+y o- gro obg n..lygr.d.ol<.ASSro of to 2-.•roe 11 o ppMo 1.o..pa.ad Ice•2:•head..pp..flan a l..2..•3• L.-tr o Id M ord..d Ss.cma�Ldaf rre o•o s-plor.d as robs.•,ne...sy oaf pro.a&for son.04.0 pe.,t,lry Mont.'Too-Lots S Or op Nr polo t wv.rw.nnvilstnr.coni \ 1l .. • tqco I Fire & Building Products Technical Services: Tel: (800) 381-9312/Fax: (800)791-5500 Model BFV-N Butterfly Valve Grooved End 21/2 Inch - 10 Inch (DN65 - DN250) General Technical Description Data The Model BFV-N Grooved End But- Model .=, 7' , 4 terfly Valves(Ref. Figure 1)are indicat- BFV-N IN ing type valves designed for use in fire Sizes:ANSI Inches/DN + protection systems where a visual in- 21/2(DN65),3(DN80), " dication is required as to whether the 4(DN100),5( N125), • - valve is open or closed.They are used, 6(DN150), 8(DN200), 10(DN250) for example,as system,sectional,and Approvals pump water control valves.They have The 21 through 10 inch(DN65-DN250) /7 -- \N\ cut groove inlet and outlet connections '�' �. g Model BFV-N Grooved End Butterfly that are suitable for use with grooved Valves are UL and C-UL Listed and FM i end pipe couplings that are listed and Approved. �1 '+ approved for fire protection systems. �%t �; All laboratory listings and approvals are For applications requiring supervision for indoor and outdoor use. .% - of the open position of the valve, the . �" Gear Operators for the Model BFV-N Maximum Working Pressure fr13`'3 Butterfly Valves are provided with •21/2-8 Inch(DN65- DN200): two sets of factory installed internal 300 psi(20,7)bar switches each having SPOT contacts. • 10 Inch (DN250): Friction Loss The supervisory switches transfer their 175 psi(12,0 bar) The approximate friction loss, based on the Hazen Williams formula and ex- electrical contacts when there is move- Materials of Construction: pressed in equivalent length of pipe ment from the valve's normal open po- Body with C= 120, is as follows.The data is sition during the first two revolutions of Ductile iron conforming to ASTM A-395 based on friction loss information col- the handwheel. Body Coating lected at a typical flow rate of 15 feet WARNINGS Polyamide per second. The Model BFV-N Grooved End But- Disc •6.9 feet of 21h inch Sch.40 pipe for terfly Valves described herein must be Ductile iron conforming to ASTM A-395 the 21 inch valve. installed and maintained in compliance Disc Seal •8.7 feet of 3 inch Sch. 40 pipe for with this document, as well as with the Grade EPDM"E"encapsulated rubber the 3 inch valve. _ applicable standards of the National conforming to ASTM D-2000 •4.5 feet of 4 inch Sch. 40 pipe for Fire Protection Association,in addition Upper&Lower Stem the 4 inch valve. to the standards of any other authori- Type 416 Stainless Steel conforming •6.6 feet of 5 inch Sch. 40 pipe for ties having jurisdiction. Failure to do to ASTM 582 the 5 inch valve. so may impair the performance of Lower Plug • 11.1 feet of 6 inch Sch.40 pipe for these devices. PVC the 6 inch valve. The owner is responsible for maintain- Operator • 10.2 feet of 8 inch Sch.30 pipe for ing their fire protection system and de- Gear operator with iron housing the 8 inch valve. vices in proper operating condition. - The installing contractor or sprinkler • 12.1 feet of 10 inch Sch.30 pipe for manufacturer should be contacted the 10 inch valve. with any questions. Page 1 of 4 MARCH, 2006 TFP1510 Page 2 of 4 TFP1510 Nominal Nominal Installation Dimensions in Inches and(mm) Weight Valve Pipe Sizes O.D. A B C D E F G H (kg) 2-1/2" 2.88 3.85 11.71 3.25 5.43 6.00 7.81 2.50 22 DN65 (73;0) (98,0) (297,4) (83,0) (137,9) (152,4) (198,4) (63,5) 0 (10,0) 3" 3.50 3.85 12.25 3.54 •5.68 6.00 7.81 • 2.50 23 DN80 (88,9) (98,0) (311,1) (90,0) (144,2) (152,4) (198,4) (63,5) 0 (10,4) 4" 4.50 4.56 13.95 4.35 6.58 6.00 7.81 2.50 28 DN100 (114,3) (116,0) (354,3) (110,0) (167,1) (152,4) (198,4) (63,5) 0 (12,7) 5" 5.56 5.86 14.93 4.84 7.07 6.00 7.81 2.50 31 DN125 (141,3) (149,0) (379,2) (123,0) (179,6) (152,4) (198,4) (63,5) 0 (14,1) 6" 6.63 5.86 17.31 5.93 8.35 6.00 7.81 2.50 0.67 41 DN150 (168,3) (149,0) (439,7) (151,0) (212,0) (152,4) (198,4) (63,5) (17,0) (18,6) 8" 8.63 5.26 19.20 6.87 9.29 6.00 7.81 2.50 5.86 53 DN200 (219,1) (134,0) (487,7) (174,0) (236,0) (152,4) (198,4) (63,5) (148,8) (24,1) 10" 10.75 6.29 25.11 9.17 11.50 9.00 7.68 3.00 7.41 88 DN250 (273,1) (160,0) (637,8) (233,0) (292,1) (228,6) (195,1) (76,2) (188,2) (40,0) INDICATOR G r F 1 HANDWHEEL FLAG 1/2"NPT CONDUIT GEAR I —— , CONNECTION OPERATOR E 010 ZIV ■3 BODY l 1 J _ / I I \ 1 B ± DISC H ■ � I I/ C �Y 1 A FIGURE 1 MODEL BFV-N GROOVED END BUTTERFLY VALVE -NOMINAL DIMENSIONS- TFP1510 Page3of4 Installation The Model BFV-N Grooved End But- terfly Valves may be installed with flow I I—SUPERVISORY in either direction and can be posi- I I SWITCH tioned either horizontally or vertically. The grooved end pipe couplings used I I SWITCH SHOWN • with the Model BFV-N must be listed L _ _ J VALVE N FUULL LL OPEN or approved for fire protection service 3 and installed in accordance with the o 9 < a manufacturers instructions. > > 0 0 The Model BFV-N Butterfly Valve may be installed with any schedule of pres- sure class of pipe or tubing that is list- END OF LINE PANEL ed or approved for fire protection. RESISTOR As applicable, refer to Figure 2 for the internal switch wiring diagram. Conduit and electrical connections I I— AUXILIARY are to be made in accordance with GND SWITCH the authority having jurisdiction and/ I I or the National Electrical Code. With I I SWITCH SHOWN reference to Figure 2, the "supervi- J WITH VALVE sory switch" is intended for connec- — o FULL OPEN tion to the supervisory circuit of a fire W Li a w alarm control panel in accordance with ii o it m NFPA 72. The "auxiliary switch" is in- c5 > °z tended for the unsupervised connec- tion to auxiliary equipment in accor- - + BELL dance with NFPA 70, National Electric Code. POWER + NOTE For outdoor applications with inter- nal supervisory switches, it is recom- mended that wiring connections be made at a temperature above 15°F CONTACT RATING ' 1/2A' /4A®250 VDC (-9°C),in order to insure sufficient flex- 15.1A/12HP @ 125,250 VAC ibility of the wire lead insulation. 5A®125 VAC•L' Care and FIGURE 2 MODEL BFV-N BUTTERFLY VALVE Maintenance -INTERNAL SWITCH WIRING DIAGRAM- The owner is responsible for the in- spection,testing,and maintenance of their fire protection system and devic- NOTE es in accordance with the applicable Before closing a fire protection system standards of the National Fire Pro- control valve for maintenance or in- - tection Association (e.g., NFPA25), in spection work on either the valve or fire addition to the standards of any au- protection system which it controls, thority having jurisdiction.The install- permission to shut down the affected ing contractor or product manufac- fire protection systems must be ob- . turer should be contacted relative to tained from the proper authorities and any questions. Any impairment must all personnel who may be affected by be immediately corrected. this decision must be notified. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified in- spection service. Page 4 of 4 TFP151O Limited Ordering Warranty Procedure Products manufactured by Tyco Fire Grooved End Butterfly Valves: & Building Products (TFBP) are war- Specify: (specify inch size) Model ranted solely to the original Buyer for BFV-N Grooved End Butterfly Valve ten(10)years against defects in mate- with internal supervisory switches, • rial and workmanship when paid for P/N(specify). and properly installed and maintained Valve Size Valve Part Number under normal use and service. This 21/2 59-300-F-025N warranty will expire ten(10)years from 3 59-300-F-030N date of shipment by TFBP. No warran- 4 59-300-F-040N ty is given for products or components 5 59-300-F-050N manufactured by companies not af- 6 59-300-F-060N filiated by ownership with TFBP or for 8 59-300-F-080N products and components which have 10 59-300-F-010N been subject to misuse, improper in- stallation,corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,special or consequential dam- ages,including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties,ex- press or implied, including warranties of merchantability and fitness for a par- _ ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products,materi- - als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law.The invalidity, in whole or part,of any portion of this warranty will not affect the remainder. TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 - CHECK VALVES FIGURE 590F Grooved End Check Valve . All Figure 590F Check Valves have been designed with a removable cover for ease of tt�` field maintenance. They can be installed either horizontally or vertically in system with flow in either the upward or downward direction. The maximum working ti- pressure is 300 psi(2063 KPa). The standard seal is Grade"E"EPDM. P P Applications:Figure 590F Check Valves are general purpose valves intended for use 116.._ in fire protection systems as follows: , 1. From public water supplies to automatic sprinkler or standpipe systems. 2. From fire department pumper connections to automatic sprinkler or standpipe systems. U 41> ® 3. In fire pump discharge or bypass piping. 4. From gravity,suction,or pressure tanks to automatic sprinkler systems. See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. A B au I_ - D ii 4,1 - CHECK �. / VALVE , I- " •• ~ 1/2"NPT J 1/2"NPT -E� F Figure 590F -Check Valves A B C D E F J Net Wt. Size Inches Inches Inches Inches Inches Inches Inches Lbs. Inches mm mm mm mm mm mm mm Kg. 2,W„ 8.00 5.80 3.41 3.40 3.88 6.00 1.70 10.0 203.2 147.3 86.6 86.4 98.6 152.4 43.2 4.5 - 3„ 8.37 5.76 3.60 3.40 3.88 6.00 1.70 11.0 212.6 146.3 91.4 86.4 98.6 152.4 43.2 5.0 4„ 9.63 6.74 4.61 3.63 4.53 7.13 1.84 25.0 244.6 171.2 117.1 92.2 115.1 181.1 46.7 11.3 5„ 10.50 7.50 5.29 4.20 4.90 7.60 1.90 29.0 2.66.7 190.5 134.4 106.7 124.5 193.0 48.3 13.2 6" 11.50 8.05 5.75 4.50 5.00 7.60 1.48 47.0 292.1 204.5 146.1 114.3 127.0 193.0 37,6 21.3 8„ 14.00 10.25 7.75 5.62 5.45 8.40 2.20 66.0 - 355.6 260.4 196.9 1-12.7 138.4 213.4 55.9 29.9 Refer to General Notes on Page 8. Check Valve FIGURE 590E MAINTENANCE KIT Maintenance Kit for Figure 590F Check Valve The Maintenance Check Valve Kit is designed to allow the maintenance Warning: procedure of backflushing through the fire department connection without The Maintenance Cap is provided with warning labels and tags to removing the Figure 590F Check Valve from the pipe line. This is indicate that the check valve is out of service. accomplished by replacing the cap/clapper assembly with the maintenance • kit(see Installation Section for full procedure). Any system maintenance or inspection that involves placing a valve IMPORTANT: "out-of-service"will eliminate the fire protection normally provided by the fire protection system. Prior to proceeding,be certain to secure All replacement parts must be obtained from permission from all Authorit/es Haring Jurisdiction and notify all the manufacturer to assure proper operation personnel who may be affected during system shutdown. A fire watch of the valve. during maintenance periods is a recommended precaution. Never remove any piping component without verifying that the system is depressurized and drained. The owner is responsible for the proper operating condition of all fire protection devices and accessories. The NFPA Standard 25 entitled, "Care and Maintenance of Sprinkler Systems"contains guidelines and minimum maintenance requirements. Futhennore,theAuthorily Having Jurisdidion may have additional regulations and requirements for maintenance,testing and inspection that must be obeyed. Step 1:Verify that the system is depressurized and drained on both sides of the Step 5:Insert the Maintenance Cap(supplied). Tighten all bolts(supplied) Check Valve. uniformly to bring the cap and gasket firmly together and ensure that the bolts are sufficiently torqued to the proper values. Step 2:Remove the bolts from the cap and remove cap with clapper assembly and cap gasket from the check valve. Inspect the elastomer seal rM NI facing on the spring loaded clapper to verify that there is no damage. " 1.3. If there is damage to the elastomer seal,a clapper repair kit will be OUT OF ^ MAINTENANCE required SERVICE CAP,GASKET (Contact Tyco Fire Products for details). TAG — AND BOLTS II,II• I1111 IN��NI GASKET C `�j p CAP 11111 11111 CAP WITH BOLTS CLAPPER ASSEMBLY Cover Bolt Torque Check 11 ,11 11111I 1 Size Bolt Torque ^ - Inches Lbs.-ft. IIII1 (I I II 2W 3" 30 4",5" 32 6" 'S4 8" 58 Step 3:Inspect the seat surface to verify it is free of all loose debris and dirt which could affect proper sealing. Step 6:Backflush the system. When done backflushing,verify that the system is depressurized and drained. - Step 4:Clean the surface for the cap gasket and place the new gasket (supplied)on the cleaned surface. Step 7:Remove the bolts from the maintenance cap,and remove the cap. Step 8:Replace the cap with clapper assembly(removed in Step 2)into the Check Valve body. Torque all bolts(per torque values in Step 5), uniformly bringing the cap and gasket firmly together. Step 9:Restore system into service. Check Valve - tqco I Fire & Building Products Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 Model 513 (13) Riser Manifold 1-1/2 thru 6 Inch (DN40 thru DN 15O) For NFPA 13 Sprinkler Systems General Technical ----.... Description Data - ..,.-1.: -�' The Figure 513 (13) Riser Manifolds Approvals ,:.1e+ described in this technical data sheet The Figure 513 (13) Riser Manifolds t provide the necessary waterflow with a cover tamper switch for the wa- - alarm, pressure gauge, alarm test ori- terflow alarm switch are UL Listed, Tice, drain, and sight glass equipment ULC Listed, and FM Approved. Ow in a single assembly for use in NFPA The Figure ure 513 13 Riser Manifolds �^ 13 sprinkler systems as follows: g ( ) ' without a cover tamper switch for the f „k• NFPA 13* waterflow alarm switch are UL Listed 1 '" ' and FM Approved. • 1-1/2 Inch (DN40) , Male Thread x Female Thread Maximum Working Pressure ' • 1-1/2 thru 6 Inch(DN40 thru DN150) 175 psi(12,1 bar) k _ Groove x Groove Test Orifice 5.6K(80K) *Although the Riser Manifold described in Assembly nections and/or listed mechanical this data sheet is Intended for NFPA 13 The manifold body of the Figure 513 is sprinkler systems,it may be used for NFPA y ure g grooved connections, as applicable 13D or 13R residential sprinkler systems, ductile iron, whereas the manifold where a test orifice of 5.6K(80K )is accept- body of the Figure 13 is cast iron.The Step 2. Connect the drain line, and able. two assemblies are completely inter- then close the drain valve. changeable in function, application. Step 3. Refer to Figure 3 for wiring The variety of sizes and grooved end and end-to-end laying length. guidance. All wiring must be per- connections allow cost effective and Finish formed in accordance with the Author- easy transition to check valves,control Red painted. ity Having Jurisdiction and/or the Na- valves, and system piping. The Riser tional Electrical Code. Manifolds may be installed in either the horizontal(flow switch on top)or verti- Installation Step 4. Refer to Figure 4 for optional relief valve. cal (flow going up) for both single sprinkler rises and floor control in high The Riser Manifolds may be installed Step 5.Place the system in service by . rises. in either the horizontal (flow switch on filling the system with water.When fill- top) or vertical (flow going up). The ing the system, partially open the con- WARNING inlet of the Riser Manifold may be di- trol valve to slowly fill the system. Fill- The Riser Manifolds described herein rectly connected to a shut-off control ing the system slowly will help avoid - must be installed and maintained in valve. damaging the waterflow alarm switch. compliance with this document, as After the system is fully pressurized, well as with the applicable standards NOTES completely open the control valve. of the National Fire Protection Asso- Where applicable pipe thread sealant ciation, in addition to the standards of is to be applied sparingly. Use of a Step 6. Secure all supply valves any other authorities having jurisdic- non-hardening pipe thread sealant is open. tion.Failure to do so may impair the recommended. performance of these devices. Never remove any piping component The owner is responsible for maintain- nor correct or modify any piping defi- - ing their fire protection system and de- ciencies without first depressurizing vices in proper operating condition. and draining the system. The installing contractor or sprinkler Step 1. Install the manifold body with manufacturer should be contacted the flow arrow pointing in the down- with any questions. stream position using threaded con- Page 1 of 6 APRIL, 2006 TFP962 Page 2 of 6 TFP962 NO. DESCRIPTION QTY. P/N 1 1-1/2"Manifold Body, Male x Female NPT 1 N/A NOTES: Groove x Groove 1 N/A 1. Approximate weight,11.2 lbs.(5,1 kg). 2 Waterflow Alarm Switch: 2. ULC Listed Manifolds are equipped with VSR-SF with Paddle, Cover Tamper Switches Installed internal UL/FM 1 971-096-00 to the WaterflowAlarm Switches. VSR-SF with Paddle and 3. CH:Common Hardware Cover Tamper Switch, • ULC/FM 1 976-519-02 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 3 n lIE I � Ali 10"(254,0 mm) ,—D Q IN 111701 14-1/4" Male x Female NPT, .q P' (362,0 mm) Groove x Groove ]IIi'III Manifolds OD m 11-1/8"(282,6 mm) Inspectors Test Male x Male NPT &Drain Valve ■■ , Drain Valve (Normally set ■:-A (Normally Manifolds to"Drain") � Closed) L] - O 1 / — I 1 2 5-3/16" 3-1/2" 3/4" 1" (131,8 mm) (88,9 mm) (19,1 mm) NPT 6-1/8" (155,6 mm) 12-5/8" (320,7 mm) FIGURE 1 1-1/2 INCH(DN40)RISER MANIFOLD ASSEMBLY AND DIMENSIONS TFP962 Page 3 of 6 • 2 INCH(DN50)MANIFOLD 4 INCH(DN100)MANIFOLD 6 INCH(DN150)MANIFOLD NO. DESCRIPTION QTY. P/N NO. DESCRIPTION QTY. P/N NO. DESCRIPTION QTY. P/N 1 2"Manifold Body, 1 4"Manifold Body, 1 6"Manifold Body, Groove x Groove • 1 N/A Groove x Groove 1 N/A • Groove s Groove • 1 N/A 2 Waterflow Alarm Switch: 2 Waterflow Alarm Switch: 2 Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle, VSC with Paddle, UL/FM 1 976-357-01 UL/FM 1 976-357-04 UL/FM 1 976-357-05 VSC with Paddle and VSC with Paddle and VSC with Paddle and Cover Tamper Switch, Cover Tamper Switch, Cover Tamper Switch, ULC/FM 1 976-520-01 ULC/FM 1 976-520-04 ULC/FM 1 976-520-05 3 300 psi/2000 kPa 3 300 psi/2000 kPa 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 Water Pressure Gauge .. 1 2341 Water Pressure Gauge .. 1 2341 2-112 INCH(DN65)MANIFOLD Manifold Nominal Installation Dimensions in Inches and(mm) Drain Size Weight NO. DESCRIPTION QTY. P/N Size A B C D E F G H lbs.(kg) 2 Inch 16-3/4 13 9/16 5-3/8 6-3/8 13-1/16 3-1/2 1"NPT 13.5 1 2-1/2"Manifold Body, (DN50) (425,5) (330,2) (14,3) (136,5) (161,9) (331,8) (88,9) __(6,1)__ Groove x Groove 1 N/A 2-1/2 Inch 17-3/16 13 1 5-3/4 6-7/8 13-3/4 3-1/2 16,8 2 Waler/low Alarm Switch: 1-1/4"NPT VSC with Paddle, (DN65) (436,6) (330,2) (25,4) (146,1) (174,6) (349,3) (88,9) (7,6) UL/FM 1 976-357-02 3 Inch 17-3/16 13 1 6 7-1/8 14-1/4 3-1/2 1.1/4'NPT 18.7 VSC with Paddle and (DN80) (436,6) (330,2) (25,4) (152,4) (181,0) (362,0) (88,9) (8,5) Cover Tamper Switch, 4 Inch 20-1/2 13 4-5/16 7-9/16 9-1/16 16-5/8 4-1/2 2"NPT 32.7 ULC/FM 1 976-520-02 (DN100) (520,7) (330,2) (109,5) (192,1) (230,2) (422,3) (114,3) (14,8) 3 300 psi/2000 kPa 6 Inch 20-1/2 13 4-5/16 8-1/2 10 18-1/2 6-5/8 2"NPT 41.6 Water Pressure Gauge .. 1 2341 (DN150) (520,7) (330,2) (109,5) (215,9) (254,0) (469,9) (168,3) (18,9) _ 3 INCH(DN80)MANIFOLD NO. DESCRIPTION QTY. P/N 1 3 IL/ 1 3"Manifold Body, Groove x Groove 1 N/A 2 Waterflow Alarm Switch: VSC with Paddle, MIL U ■ L/FM 1 976-357-03 U -,NM VSC with Paddle and ,<It> Ii Cover Tamper Switch, (Normally Drain Valve M I. 7 ULC/FM 1 976-520-03 Closed) 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 NOTES: A - a, 2 1. ULC Listed Manifolds Switches are equipped with Iii A.o Cover Tamper Switches installed internal B _ to the Waterflow Alarm Switches. - .4 1 2. CH:Common Hardware limp V � .. I■ L©,- _ , } I ... _ I . L. Test C D~ _-G& Valve - � (Normally set E to"Drain") H F FIGURE 2 2 thru 6 INCH(DN50 thru DN150)RISER MANIFOLD ASSEMBLY AND DIMENSIONS Page 4 of 6 TFP962 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS `CONDUCTOR single conductor is not � SEPARATE . permitted to be looped around CONDUCTORS CLAMPING the terminal and serve as two `"' PLATE separate connections.The TERMINAL wire must be severed to serve ', INCOMING eN as two separate connections, 0• � thereby providing supervision of� that the connection wirbecomes in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS SPDT(Form C) END OF LINE LOCAL RESISTOR CONTACT RATING .... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE ` NC NO ti NC ro NO• �G NC i// COM COM COM CONTROL POWER PANEL NO FLOW NON-SUPERVISED STYLE B/CLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterfiow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remove signaling unit,while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH(ULC ASSEMBLIES ONLY) CONTACTS SPDT(Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1 mA @ 5 VDC min. NO\ • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 3 WIRING GUIDANCE TFP962 Page 5 of 6 • NO. DESCRIPTION QTY. PIN NO. DESCRIPTION QTY. P/N 1-1/2"(DN40)Manifold Only: To install optional Pressure Relief Trim on 1 3/8'Copper Tubing, 2 Pressure Relief Valve, a 1-1/2"(DN40)Manifold,a 1/2"NPT outlet 2"(DN50)Manifolds .... 1 971-124-01 175 psi,Nonadjustable .. 1 198-066-00 must be provided by the installer on the 2-1/2"(ON65)and 3 90'Compression Fitting system outlet piping,and a connection back 3"(DN80)Manifolds .... 1 971-124-02 Fitting 2 CH to the manifold drain trim must be fabricated 4'(DN100)and 4 1'x 1/2"Reducing Hex with installer supplied 3/8"copper tubing. 6"(DN150)Manifolds ... 1 971-124-03 Bushing 1 CH Discard unused trim components. CH:Common Hardware • .--r—) 3 1/2"NPT Installer Outlet Provided System Outlet 1 3 4 ilia Piping ti il Installer Fabricated rl Q'' 3/8'Copper � tt Tubing __ 0 II (DN65), ll� t> 3"(DN80),4"(DN100),or —D Q Ile ■ 6"(DN150)Manifold il 'q P' Manifold 3 1111311111 Drain Trim I _in _ .. N ..__I U I 1-112"(DN40) ■ _ Manifold , ,0..\,- ,O Mil Mil =MI= FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE Riser Manifold component in the field. Alarm/Flow Test Procedure Care and Only the pressure gauge, waterflow alarm switch, or relief valve can be Step 1.Place the test&drain Valve in Maintenance replaced. if any other problems are the"test"position. encountered the entire riser manifold Step 2. Fully open the drain valve. The following inspection procedure must be replaced. must be performed as indicated,in ad Make certain that drainage water will dition to any specific requirements of The alarm/flow test procedure will re- not cause any damage or injury. the NFPA, and any impairment must suit in operation of the associated Step 3.Verify operation of associated be immediately corrected. alarms. Consequently, notification alarms. must be given to the owner and the fire The owner is responsible for the in- department, central station, or other Step 4. Close the drain valve. spection, testing, and maintenance of signal station to which the alarms are Step 5.Place the test&drain Valve in - their fire protection system and de- connected, and notification must be the"drain"position. vices in compliance with this docu- given to the building occupants. ment, as well as with the applicable Step 6. Verify that the residual (flow- standards of the National Fire Protec- Before closing a fire protection system ing ) pressure indicated by the (flow - standards Association (e.g., NFPA 25), in control valve for inspection or mainte- sure gauge is no less that originally addition to the standards of any nance work on the fire protection sys- recorded for the system when it was authority having jurisdiction. The in- tem that it controls,permission to shut first installed. stalling contractor or product manufac- down the effected fire protection sys Curer should be contacted relative to tem must first be obtained from the Step 7.Close the drain valve. any questions. proper authorities and all personnel Step 8.Verify that the static(not flow- who may be affected by this action ing) pressure indicated by the pres It is recommended that automatic must be notified. sprinkler systems be inspected, sure gauge is no less that originally - tested, and maintained by a qualified After placing a fire protection system recorded for the system when it was Inspection Service in accordance with in service,notify the proper authorities first installed. local requirements and/or national and advise those responsible for moni- codes. toring proprietary and/or central sta- tion alarms. NOTES No attempt is to be made to repair any Page 6 of 6 TFP962 Limited Ordering Warranty Information Products manufactured by Tyco Fire& Riser Manifold: Building Products (TFBP) are war- Specify; Size (specify), Figure 513, ranted solely to the original Buyer for (specify connection type inlet x outlet) ten(10)years against defects in mate- Riser Manifold (specify - without or rial and workmanship when paid for with) a cover tamper switch for the and properly installed and maintained waterflow alarm switch, P/N (specify). under normal use and service. This warranty will expire ten (10) years NOTES from date of shipment by TFBP. No Orders for Figure 513 may be filled warranty is given for products or corn- with a Figure 13. The two assemblies ponents manufactured by companies are completely interchangeable in not affiliated by ownership with TFBP function, application, and end-to-end or for products and components which laying length. have been subject to misuse,improper If a ULC Listing is required, the Riser installation, corrosion, or which have Manifold must be ordered with a cover not been installed, maintained, modi- tamper switch for the waterfiow alarm fled or repaired in accordance with ap- switch. plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities UL/ULC/FM Assemblies Having Jurisdiction. Materials found With Cover Tamper Switch by TFBP to be defective shall be either 1-1/2 Inch(DN40) repaired or replaced, at TFBP's sole MT x FT P/N 4086 option. TFBP neither assumes, nor 1-1/2 Inch(DN40) authorizes any person to assume for it, MT x N5 MT P/N 4087 y P 2 (ON50) any other obligation in connection with G x G P/N 4090 the sale of products or parts of prod- 2-1 2 Inch(DN65) P/N 4091 ucts.TFBP shall not be responsible for 3 Inch(DN80) sprinkler system design errors or inac- G x G PIN 4092 curate or incomplete information sup- 4 Inch(DN100) plied by Buyer or Buyer's repre- G x G P/N 4095 sentatives. 6 Inch(0N150) G x P/N 4096 In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, UL/FM Assemblies indirect,special or consequential dam- Without 2 Cover Tamper switch P q 1-1/2 Inch(DN40) ages, including but not limited to labor MT x FT P/N 4055 charges, regardless of whether TFBP 1-1/2 Inch (DN40) was informed about the possibility of MT x MT P/N 4056 such damages, and in no event shall 2 Inch(DN50) TFBP's liability exceed an amount G x G P/N 4060 y 2-1/2 Inch(DN65) equal to the sales price. G x G P/N 4061 3 Inch(DN80) The foregoing warranty is made in lieu G x G P/N 4062 of any and all other warranties. ex- 4 Inch(DN100) press or implied, including warranties G x G P/N 4065 of merchantability and fitness for a par- - 6 Inch(ON1so) ticular purpose. G x G P/N aoss This limited warranty sets forth the ex- clusive remedy for claims based on Optional Pressure Relief Valve: failure of or defect in products,materi- Specify: Operational Pressure Relief als or components, whether the claim Valve and Trim for use with (specify is made in contract, tort, strict liability size) Figure 513 or 13 Series Riser or any other legal theory. Manifold, P/N (specify). This warranty will apply to the full ex- tent permitted by law.The invalidity,in 1-1;21 "or 2" P/N 4063 whole or part, of any portion of this 4°or 6 r 3- P/N 4073 warranty will not affect the remainder. Replacement Parts: Specify: (description)for use with Fig- ure 513 or 13 Riser Manifold,P/N(Ref. Figure 1 or 2, as applicable). TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 OSYSU-1 , -2 OUTSIDE SCREW AND YOKE VALVE - - SUPERVISORYSWITCH FIG. 1 SMALL VALVE INSTALLATION - 1/2" THRU 2 1/2" SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2"TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2". J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET CLAMP BAR `== ~ BRACKET MINN Mr CARRIAGE BOLT =� S rr / DWG. #979-3 SMALL VALVE INSTALLATION 1. Remove and discard"C"washer and roller from the trip 6. Remove the OSYSU. File a 1/8"deep groove centered on rod. the mark on the valve stem utilizing a 3/16"round,non- 2. With the valve in the FULL OPEN position,locate the tapered file. Round and smooth the edges of the groove to OSYSU across the valve yoke as far as possible from the prevent damage to the valve packing and to allow the trip valve gland,so that the trip rod lays against the non- rod to move easily in and out of the groove as the valve is threaded portion of the valve stem. operated. 3. Loosen the locking screw that holds the trip rod in place Mount the OSYSU with the trip rod centered in groove. and adjust the rod length(see Fig.4). When adjusted 8. Final adjustment is made by loosening 2 screws(see Fig. properly,the rod should extend past the valve screw,but 1)and sliding the OSYSU on the bracket. Adjustment is not so far that it contacts the clamp bar. Tighten the correct when switches are not activated with the trip rod locking screw to hold the trip rod in place. seated in the valve stem groove and that the switches NOTE: If trip rod length is excessive,loosen the locking activate when the trip rod moves out of the groove. screw and remove the trip rod from the trip lever. Using 9. Tighten the adjustment screws and all mounting hardware. pliers,break off the one(1)inch long notched section(see Check to insure that the rod moves out of the groove easily Fig.5). Reinstall trip rod and repeat Step 3 procedure. and that the switches activate within one turn when the 4. Mount the OSYSU loosely with the carriage bolts and valve is operated from the FULL OPEN towards the clamp bar supplied. On valves with limited clearance use CLOSED position. J-hooks supplied instead of the carriage bolts and clamp NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT bar to mount the OSYSU. THE STEM THREADS DO NOT ACTIVATE THE SWITCH. 5. Mark the valve stem at the center of the trip rod. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT.#8820004-REV N PAGE 2 OF 4 9,99 OSYSU-1 , -2 OUTSIDE SCREW AND YOKE VALVE . r-,. POTTER SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION -3"THRU 12" SIZES 3" THRU 12" VALVES USE CARRIAGE BRACKET BOLTS. CARRIAGE BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS O SLOTTED MOUNTING _ (2 REQUIRED) HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT OF SWITCH ON BRACKET. -���i `:r-Atto GYOOOEE jiTt VALVE STEM TRIP ROD DWG. #979-4 AND LARGE VALVE INSTALLATION 1. With the valve in the FULL OPEN position,locate the to prevent damage to the valve packing and to allow the OSYSU across the valve yoke as far as possible from the trip rod to move easily in and out of the groove as the valve gland,so that the trip rod lays against the non- valve is operated. threaded portion of the valve stem. 6. Mount the OSYSU loosely with the trip rod centered in 2. Mount the OSYSU loosely with the carriage bolts and groove. clamp bar supplied. 7. Final adjustment is made by loosening 2 screws(see Fig. 3. Loosen the locking screw that holds the trip rod in place 2)and sliding the OSYSU on the bracket. Adjustment is and adjust the rod length(see Fig.4). When adjusted correct when switches are not activated with the trip rod - properly,the rod should extend past the valve screw,but seated in the valve stem groove and that the switches not so far that it contacts the clamp bar. Tighten the activate within one turn when the valve is operated from the locking screw to hold the trip rod in place. FULL OPEN towards the CLOSED position. - NOTE: If trip rod length is excessive,loosen the locking 8. Tighten the adjustment screws and mounting hardware. screw and remove the trip rod from the trip lever. Using Check to insure that the rod moves out of the groove pliers,break off the one(1)inch long notched section(see easily and that the switches activate within one turn when Fig.5). Reinstall trip rod and repeat Step 3 procedure. the valve is operated from the FULL OPEN towards the CLOSED position. 4. Mark the valve stem at the center of the trip rod. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT 5. Remove the OSYSU. File a 1/8"deep groove centered on THE STEM THREADS DO NOT ACTIVATE THE SWITCH. the mark of the valve stem utilizing a 3/8"round,non- THE SWITCH BEING ACTIVATED BY THE STEM THREADS tapered file. Round and smooth the edges of the groove COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT.#8820004-REV N PAGE 3 OF 4 9/99 OSYSU-1 , -2 fOUTSIDE SCREW AND YOKE VALVE ry SUPERVISORYSWITCH FIG. 3 DIMENSIONS FIG. 4 PARTS e.to - IQ1 KOUTS (OR EtEcn i r/! ,% - 4.76 - 2s5 COMEC710NS 11'' mica 1 1--2.aD a wi' (P� r,�11, , i GROUND SCREW ` i � TPoP ROD i )n- tOCKINO SCREW 3AO �t � c�0 � � L_ I E - . Lam/. ' (�41416:'O t O I iRP ROD 588 I S. I egoj° 'LLII I --. ,.__Io S' - T RGD RETRACTED .ea _= 7b8 SECTION REMOVED i 1,--1.155—' T1 II I I I �� V I I r I I �s Roo EXPENDED 4Tj DWG.X1879-s V DV6 $979-6 BREAKING EXCESSIVE ROD SWITCH TERMINAL TYPICAL ELECTRICAL CONNECTIONS LENGTH CONNECTIONS CLAMPING PLATE LOCAL sawn IT N.O. FIG. 5 TERMINAL co�� .D EN" NC TO 'OWRFDR DEVICE INDICATING ONCE Ap ‘oia.N... 1.. .... .___ TO CONTROL P MUTT LI.N.D. / OF CDNlat7L PANEL 0 E MC N.D. RESISTOR C+.,1 ds` am p¢3 OMK1.1676-1 M►' CAUTION: Contacts shown in normal(valve open)condition. D1rF 1911-1 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections.The wire TYPICAL SWITCH ACTION must be severed,thereby providing supervi- sion of the connection in the event that the wire OPEN VALVE POSITION CLOSED VALVE POSITION becomes dislodged from under the terminal. COM. CON. N.O. SW ORDERING INFORMATION #1 sw #T N.C. I `KC. MODEL DESCRIPTION STOCK NO. I I OSYSU-1 Outside Screw&Yoke-Supervisory Switch(Single switch) 1010106 I � I OSYSU-2 Outside Screw&Yoke-Supervisory Switch(Double switch) 1010206 CON.I ♦ N O COM. 1 N.O. -- Cover Screw 5490344 SW #Z SW #2 J -- Hex Key for Cover Screws and Installation Adjustments 5250062 N.C. -N.C. -- Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits(if required)contact valve manufacturer. DWG. #979-2 PRINTED IN USA MKT.#8820004-REV N PAGE 4 OF 4 9/99 r'',Fde.. BELLS AX 4;f' PBA-AC & PBD-DC ..,:.:-....:..:..«..�......... ....N.,..w..An.aewe.ra•.a.,..vs..,.,....•,.n....i...A.yaw.aw...o..,w.mw,.,..�..,.:...+....�,.v:,,,,.,M...,...0+.ate..-,.d...,..«.�... UL Listed, FM Approved Sizes AvaTble:6"(150mm),8"(200mm)and 10"(250mm) " ! fi`& Voltages Available: 24VAC fI 1j .'` 120VAC f ; '. 12VDC (10.2 to 15.6)Polarized 24VDC (20.4 to 31.2) Polarized ‘.:;.-1.4ffts Service Use Fire Alarm 7) ter" ,; General Signaling <6> ;1 Burglar Alarm _-' Environment: Indoor or outdoor use (See Note 1) L: 40°to 150°F ( 40° to 66°C) `, .r z., t`t ,- (Outdoor use requires weatherproof :. ^' backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general signaling devices. They have low power con- sumption and high decibel ratings.The unit mounts on a standard 4"(101 mm)square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1,Stock No.1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE CURRENT TYPICAL dB MINIMUM dB INCHES VOLTAGE MODEL NO. STOCK NO. AT 10 FT. AT 10 FT. (mm) (MAX.) (3m)(2) )3m)(1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8(200) 12VDC P80128 1708012 .12A 90 76 10(250) 12VDC P801210 1710012 .12A 92 76 6(150) 24VDC P80246 1706024 .06A 87 76 8(200) 24VDC P80248 1708024 .06A 91 79 10(250) 24VDC P802410 1710024 .06A 94 79 6(+S') 24VAC PBA.2.6 '0°6'24 17A 9+ 76 8(200) 24VAC P8A248 1808024 .17A 94 76 10(250) 24VAC P8A2410 1810024 .17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10(250) 120VAC PBA12010 1810120 05A 99 85 Notes: _ 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is-30°to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative - of output levels in an actual installation. Potter Electric Signal Company •2081 Craig Road,St.Louis,MO,63146-4161 • Phone:800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT.#8850001-REV P PAGE 1 OF 2 MFG.#5400776-3/99 t 3Y :.ate:1, BELLS Y. PBA-AC & PBD-DC DIMENSIONS INCHES (mm) FIG. 1 BELLS FIG. 2 WEATHERPROOF BACKBOX • BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE 1 �± o 10" 5 3/4• 3 3/8• g• (250) -l�--) (146) O (86) (127) B 11 .,i, I (2080) 6• (150) � I I LJ�`7 J �1 5/S.I 33/0" (41) IL1` 4 1/4' +72 1116-V►- (108) I (68) I DWG. #778-1 DWG. 1776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED(IN) RED(OUT) WHITE(IN) WHITE(OUT) FROM CONTROL PANEL �/ TO NEXT BELL TRON CONTROL PANEL i OR OR END-Of-ONE OR PRECEMNC BELL '�'' RESO1GR PRECEDING BELL BLACK(IN) -� BLACK OU ELACK (IN) -� BLACK (OUT) CAU DON; SALEM WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.G. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY 2. RED WIRES POSITIVE (+) AFTER LAST BELL 3. BLACK WIRES NEGATIVE (-) 2. END-OF-UNE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. //776-3 - INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2.4m)from the floor or as close to the ceiling as possible. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT.#8850001-REV P PAGE 2 OF 2 MFG.#5400776-3/99 WILKINS Model 850 a ZURN.company Full Port Brass Ball Valve SPECIFICATION SUBMITTAL. SHEET t APPLICATION WILKINS Model 850 Full Port Brass-Ball Valves are recom- t y mended for residential,commercial and industrial applica- tions. Ideal for throttling and balancing installations of low Size 112"-2" pressure steam, air,water and non-corrosive gas or oil. FEATURES MATERIALS Sizes: ❑ 1/4" ❑ 3/8" ❑ 1/2" Main valve body Bronze ASTM B 584 ❑ 1'/." ❑ 1'/" ❑2" Ball Chrome plated brass ASTM B 16 Seats TFE virgin teflon Pressure rating 600 psi WOG Stems Brass ASTM B 16 Temperature rating 33°F to 350°F Stem packing TFE virgin teflon @50 psi Thrust washer TFE virgin teflon Threaded connections(FNPT) ANSI B1.20.1 Handle Electroless nickel plated Handle nut Electroless nickel plated OPTIONS (Suffixes can be combined) ❑ - FNPT x FNPT connections,(1/2"-2") ❑ M - MNPT x FNPT connections, (1/4"-1/2") ❑ - with BSP threads Models 850&850T (3/4"-2") r-C--I ❑ T - tapped(FNPT X FNPT) f _ il _ I MI ❑ C - with copper sweat connections(FC x FC) B❑ U - with single union body(FNPT x FNPT) i111 ' �,,,I _� U❑ SH - with stainless steel handle A� ED �_i F�Y ' A� D '� Size 112"-2" Size 1/4"-318" DIMENSIONS&WEIGHTS(do not include pkg.) DIMENSIONS(approximate) MODEL 850 MODEL 850U 850M . SIZE D E F A A A A A A B C THREAD TAP SIZE THREAD wE1GFfT TAPPED TAPPED PPED FNPT FNPT NWT ED in. rrm in. rrm in. rim in. mm in. rrm lbs. kg. 1/4 N/A N/A N/A NIA N/A N/A 2 1/8 54 2 5/8 1 5/8 41 2 5/8 67 1/4-18 1/8-27 1/4-18 1 0.5 3/8 N/A N/A N/A N/A N/A N/A 2 1/8 54 2 1/4 1 5/8 41 2 5/8 67 3/8-18 1/8-27 3/8-18 1 0.5 1/2 2 1/4 57 2 1/2 N/A N/A N/A 2 5/8 67 2 1/4 1 7/8 48 2 3/4 70 1/2-14 1/8-27 1/2-14 1 0.5 3/4 2 1/2 64 2 3/4 3 5/16 84 3 5/8 N/A N/A N/A 1 3/4 45 1 5/8 41 3/4-14 1/8-27 N/A 1 0.5 1 2 3/4 70 3 3 7/8 94 4 1/4 N/A N/A N/A 2 51 1 5/8 41 1-11 1/2 1/8-27 N/A 2 1 1 1/4 3 5/16 84 3 5/8 4 1/4 108 4 1/2 N/A N/A N/A 2 5/8 67 3 1/2 89 1 1/4-11 1/2 1/4-18 N/A 3 1.4 1 1/2 3 3/4 95 3 7/8 4 7/8 124 5 1/4 N/A N/A N/A 2 7/8 73 4 3/4 121 1 1/2-11 1/2 1/4-18 N/A 3 1.4 - 2 4 1/2 114 4 5/8 5 5/16 135 5 5/8 N/A N/A N/A 3 7/8 98 4 3/4 121 2-11 1/2 1/4-18 N/A 6 2.7 DOCUMENT#: REVISION: BV-850(SM) 1/03 WILKINS OPERATION OF ZURN INDUSTRIES,1747 Commerce Way,Paso Robles,CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga,Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com I, S' } Brass Ball Drip Valve i, 644i 1 ,• F P P I® --)w ` Description , "The solid brass* ball drip is a"ball"type check valve. When properly installed, ., '- the internal ball rests in the lower most area of the valve body allowing for proper # drainage of moisture accumulation. Upon system pressurization,the internal ball j °` is "pushed" into the small end of the ball drip body closing the opening. When Vay_= system pressure is removed,the ball returns to its original position. One of the (' r most common uses is on the dry side of the Fire Department Connection valve. �sx This use helps keep moisture from accumulating inside the Fire Department } / i Connection. Designed for horizontal installation only. jw 1r Installation Specifications Proper installation of the brass ball drip can be accomplished with standard installation tools. Make sure the threads are clean and free from burs and Strai piping Straight Pattern debris. Apply a thread sealant suitable for the materials being joined such as PipeFit, PipeFit AS or PTFE tape.When using a paste type sealant, make sure Material: - to brush the sealant deep into the root of the threads.Thread the ball drip into Body: Brass* Ball: Brass* female threads hand tight. Finish tightening with a pipe wrench up to one full turn. Standard Finishes: Rough Brass* Do not over tighten. Over tightening may damage threads and ball drip. Adjustment Range: Finish piping to allow for proper drainage. Valve opens by force of gravity only. 1/4"x 1/2"MNPT Do not use with more than 1 ft.column of water(water pressure) on the ball 1/2"X' "MNPT check. Use only in the horizontal position. 3/4"x 3/4"MNPT *Contains lead.Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE 0 + TER S11 800 344-1822 a FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. 111111 l' i IT tqca I Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Identification Signs For Sprinkler Systems and Devices NFPA 13 Signing Requirements General WARNINGS Care and The Identification Signs described Description herein must be installed and main Maintenance p tained in compliance with this docu Identification Signs (Ref. Figure 1) are ment, as well as with the applicable The following inspection procedure designed to provide information to the standards of the Naonal Fire Pro- ti must be performed as indicated, in ad- end user about the sprinkler system tection Association, in addition to the dition to any specific requirements of and its components. They are avail- standards of any other authorities hav the NFPA, and any impairments must able with a variety of wording combi- mg jurisdiction. Failure to do so may be immediately corrected. nations to meet the signing require Impair the performance of these in- ments of NFPA 13. devices. The owner is responsible for the in- The owner is responsible for maintain their f fire testing, and maintenance of The five basic types of Identification their fire protection system and devic- Signs are as follows: ing their fire protection system and de es in compliance with this document, vices in proper operating condition. as well as with the applicable stan Type A- Control Valve Sign The installing contractor or sprinkler PP Type B- Multi-Purpose Text Signs manufacturer should be contacted Association of the National Fire in addition YP P 9 Association(e.g., NFPA 25),in addition (See Below) with any questions. to the standards of any authority hay- - Type D-Fire Alarm Sign ing jurisdiction. The installing contrac- Type E- Hydraulic Calculation Si Technical for or product manufacturer should be YP Y Sign contacted relative to any questions. Type B- Identification Signs are avail- Data It is recommended that automatic sprin- able with the following text options: kler systems be inspected, tested, and Material&Finish maintained by a qualified Inspection AIR CONTROL 18 gauge aluminum with mylar facing. AIR LINE Service in accordance with local re- AIR TEST quirements and/or national codes. Width x Height After placing a fire protection system ANTIFREEZE SYSTEM Inches (mm) in service, notify the proper authorities AUXILIARY DRAIN CONTROL VALVE Type A 9 x 7 (229 x 178) and advise those responsible for mon- itoring proprietary and/or central sta- DRAIN Type B 9 6 (152 51) tion alarms. DRAIN VALVE Type C 734 x 1'/A (197 x 32) INSPECTION PROCEDURE INSPECTORS TEST MAIN CONTROL Type D 9 x 7 (229 x 178) Annual visual inspections are recom- MAIN DRAIN Type E 5 x 7 (127 x 178) mended to ensure that Identification Signs are properly located. Installation The Identification Signs are provid- ed with 1/8 Inch (3,2 mm) diameter or larger holes(or slots)in the corners for easy attachment using standard hard- ware chain, wire, plastic lock ties, or light gauge metal strap(not included). Page 1 of 4 AUGUST, 2007 TFP1615 Page 2 of 4 TFP1615 THIS SUPPLY AUTOMATIC SPRINKLERS SPRINKLER TO • FIRE - ALARM • • MBET OPEN TIMES WHEN BELL RINGS TO BE HANDLED ONLY BY AUTHORIZED PERSON OR BY EMPLOYEE CARING FOR SPRINKLER SYSTEM CALL IN CASE OF FIRE DO NOT SHUT VALVE UNTIL FIRE IS ENTIRELY OUT FIRE DEPT OR POLICE WHEN VALVE IS SHUT FOR EMERGENCY-REPAIRS-OR FIRE- NOTIFY: REQUEST DIRECTIONS••RESTORE PROTECTION QUICKLY SIGN- TYPE A, P/N 2300A SIGN- TYPE D RECTANGULAR 6-1/2"X 8-1/2", P/N 2316 OR ROUND 7-1/4"DIAMETER, P/N 2329 • • • HYDRAULIC-SYSTEM • AUXILIARY DRAIN This Building is Protected by a • • Hydraulically Designed Automatic Sprinkler System SIGN- TYPE B, AVAILABLE WITH THE Location FOLLOWING TEXT OPTIONS "AIR CONTROL" P/N 2328 No. of Sprinklers "AIR LINE" P/N 2302 "ALARM TEST" P/N 2304A Basis of Design "ANTIFREEZE SYSTEM" P/N 2306 1. DENSITY GPMISO.FT. "AUXILIARY DRAIN" P/N 2307 "CONTROL VALVE" P/N 2310 2. DESIGNED AREA OF DISCHARGE SO.FT. "DRAIN" P/N 2311 "DRAIN VALVE" P/N 2327 System Demand "INSPECTORS TEST" P/N 2313 "MAIN CONTROL" P/N 2319 1. WATER FLOW RATE GPM "MAIN DRAIN" P/N 2320 2. RESIDUAL PRESSURE AT THE PSI BASE OF THE RISER • • SIGN- TYPE E, P/N 2317 FIGURE 1 IDENTIFICATION SIGNS TFP1615 Page 3 of 4 Limited Ordering Warranty Procedure Products manufactured by Tyco Fire Orders must include the description & Building Products (TFBP) are war- and Part Number (P/N). Contact your ranted solely to the original Buyer for local distributor for availability. ten(10)years against defects in mate Hardware for hanging is not sup rial and workmanship when paid for plied with the Sign. It must be ordered and properly installed and maintained separately. under normal use and service. This warranty will expire ten(10)years from Identification Signs, date of shipment by TFBP. No warran- (Types A,C,D,or E) ty is given for products or components Specify:Type(A,C,D,or E) manufactured by companies not af- Identification Sign,P/N(specify). filiated by ownership with TFBP or for Identification Signs products and components which have (Type B) been subject to misuse, improper in- Specify: Type B Identification Sign in- stallation,corrosion,or which have not scribed(specify,e.g. "AIR CONTROL"), been installed,maintained,modified or P/N(specify). repaired in accordance with applicable Standards of the National Fire Protec- Type A P/N 2300A tion Association,and/or the standards Type D(Round) P/N 2329 of any other Authorities Having Juris- Type D(Rectangle) P/N 2316 diction.Materials found by TFBP to be Type E P/N 2317 defective shall be either repaired or re- placed, at TFBP's sole option. TFBP Type B neither assumes, nor authorizes any "AIR CONTROL" P/N 2328 person to assume for it,any other ob- ligation in connection with the sale of "ALARM TEST" P/N 2304A products or parts of products. TFBP "ANTIFREEZE SYSTEM" P/N 2306 shall not be responsible for sprinkler "AUXILIARY DRAIN" P/N 2307 system design errors or inaccurate or "CONTROL VALVE" P/N 2310 incomplete information supplied by "DRAIN" P/N 2311 Buyer or Buyer's representatives. "DRAIN VALVE" P/N 2327 In no event shall TFBP be liable, in "INSPECTORS TEST" P/N 2313 contract, tort, strict liability or under "MAIN CONTROL" P/N 2319 any other legal theory, for incidental, "MAIN DRAIN" P/N 2320 indirect,special or consequential dam- ages,including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied. including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products,materi- - als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page 4 of 4 TFP1615 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 I,: T ,f'c Tö'1;cO INCORPORATED CORONA,CA (909)737-5599 1 I FM FIg. 200 • ® , III "Trimline"Adjustable Band Hanger Size Range– 1/2 thru 8 inch pipe. Material–Carbon Steel, Mil. Galvanized to G-90 specifications. 40:1:::.: .:. Function–For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. ," Features , •(1/2 thru 2 inch) Flared edges ease installation for all i 1 pipe types and protect CPVC plastic pipe from i B ) Is. B abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed A around pipe. ( / ' i •(2-1/2 thru 8 inch)Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals– Underwriters' Laboratories Listed (1/2" thru 8")in the U.S. (UL) and Canada(cUL)for steel and CPVC plastic pipe and Factory Mutual 1/2 THRU 2 INCH PIPE 2 1/2 THRU 8 INCH PIPE Engineering Approved (3/4"thru 8"). Conforms to Federal Specifications WW-H-171E,Type 10, and ' Manufacturers Standardization Society SP-69,type 10. ilm Maximum Temperature-650°F. ° — Finish–Mil. Galvanized, for Stainless Steel materials order Tolco Fig.200WON. Order By–Figure number and pipe size. --�� ` t \\ ,...„._________J 1\\N--........--) - PIPE ROD SIZE MAX.REC. APPROX. SIZE INCH METRIC* A B LOAD LBS. WT./100 1/2 3/8 8mm or l0mm 3-1/8 2-5/8 400 11 - 3/4 3/8 8mm or 10mm 3-1/8 2-1/2 400 11 1 3/8 8mm or 10mm 3-3/8 2-5/8 400 12 1-1/4 3/8 8mm or 10mm 3-3/4 2-7/8 400 13 1-1/2 3/8 8mm or 10mm 3-7/8 2-7/8 400 14 2 3/8 8mm or 10mm 4-1/2 3 400 15 _ 2-1/2 3/8 10mm 5-5/8 4-1/8 600 27 3 3/8 10mm 5-7/8 4 600 29 3-1/2 3/8 10mm 7-3/8 5-1/4 600 34 _ 4 3/8 10mm 7-3/8 5 1000 35 5 1/2 12mm 9-1/8 6-1/4 1250 66 6 1/2 12mm 10-1/8 6-3/4 1250 73 8 1/2 12mm 13-1/8 8-3/4 1250 136 *Order Fig. 200M 5/24/2001 -89- TOLCO INCORPORATED CORONA,CA (909)737-5599 FM Fig. 65 and Fig. 66 uL c O Reversible C-Type Beam Clamps 3/4 and 1-1/4 Inch Throat Openings Size Range–(Fig. 65 and Fig.66)3/8, 1/2,AND 5/8 inch rod. Material–Carbon Steel with hardened cup point set screw and jam nut. Function–Recommended for hanging from steel beam where flange thickness does not exceed 3/4 inch (Fig. 65)or 1-1/4"(Fig. 66) B Features–All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange 04 where clearance is limited.) May be installed with set screw in up or ,down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open Ars design permits inspection of thread engagement. F Approvals–Underwriters' Laboratories Listed in the USA(UL)and /[` Canada (cUL). Factory Mutual Engineering Approved. Conforms to Federal Specification Society SP-69,type 19 and 23. Exceeds A _ requirements of the National Fire Protection Association (NFPA), , Pamphlet#13, 3/8 inch rod will support 1/2 thru 4 inch pipe, 1/2 inch rod 1� will support 1/2 thru 8 inch pipe. Finish–Plain. Note—Available in Electro-Galvanized and HDG finish. Order By—Figure number, rod size, and finish. Fig. 65 Patent#4,570,885 B D / W, E FIG.65 TABLE A � , ROD MAX.REC. APPROX \ SIZE A B C D E F LOAD LBS.* WT./100 F 3/8 1-3/16 3/4 1 7/16 1 610 28 1/2 1-1/2 3/4 1 9/16 1-1/4 1130 55 � 5/8 1-1/2 3/4 1 9/16 1-1/4 1130 55 *O-VO*Max. loads for clamp with set screw in up or down position. 1= A 1/ FIG.66 TABLE ROD MAX.REC. APPROX - SIZE A B C D E F LOAD LBS.* WT./100 3/8 1-3/16 1-1/4 1 7/16 1 610 28 1/2 1-1/2 1-1/4 1 9/16 1-1/4 1130 55 5/8 1-1/2 1-1/4 1 9/16 1-1/4 1130 55 *Max. loads for clamp with set screw in up or down position. 5/24/2001 -62- TOLCO INCORPORATED CORONA,CA (909)737-5599 0 C u) Fig. 69 Component of State of Beam Clamp Retaining Strap OSHPD Approved g r Seismic Restraints System Size Range—3/8 thru 7/8 inch rod by 4 thru 16 inch length.* Material—Pre-Galvanized Steel. Function—To offer more secure fastening of various types of beam clamps to beam where danger of movement might CD be expected. NFPA#13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13(1999)6-4.7.1. Important Note—Good installation practice of a retaining strap requires that the strap be held tightly and securely to B all component parts of the assembly. Therefore a locking mechanism of some kind such as a hex nut or the beveled locking slot on the Tolco Fig. 69R will provide a more secure and reliable installation. Approvals—Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by State of California Office of Statewide Health Planning and Development(OSHPD). Finish—Pre-Galvanized Order By—Figure number, type, length"B", and rod size being used with beam clamp. Note—Minimum return on Strap: 1 inch. .r so TYPE ROD SIZE A HOLE SIZE B 1 3/8 7/16 Specify 1/2 9/16 Specify 2 5/8 11/16 Specify 3/4 13/16 Specify = �� • 3 3/8—7/8 Specify Specify *Longer Lengths are available,consult factory. '•' 8113/2001 -64- W _._ X000 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING - MODEL E Lotkik.. (I° Part#077 eiti rk4, JI SIZE-Sprinkler systems pipe: 1"thru 8"Steel Schedule 7 thru 40. SIZE- Sway brace assembly pipe: Steel 1"and 1 1/4" Schedule 40. MATERIAL-Carbon Steel or S.S.(Type 304). FINISH-Plain,E.G.,and H.D.G. LISTING/APPROVAL- e0a. 203A-EX 2625 Listed only for use with other AFCON bracing products. i OSHPD OPA-0601 See Website. ; PATENT-No.3,570,794 �; FUNCTION- Per NFPA 13. Sway brace fitting of a lateral sway brace assembly. To form a 4-way brace on vertical piping,arrange adjacent lateral sway braces. S4j, INS TALLATION-Per NFPA 13. Place Model E over pipe to be braced. Insert �® , brace pipe through MODEL"E"under channel bracket,leaving 1"minimum •<;� extension beyond. Tighten hex nuts until gage spring lays flat or torque to 65 in.-lbs. ASSEMBLY- Per NFPA 13. Combine with AFCON 70 series structure sway - brace fitting and pipe brace element forming a complete sway brace. FEATURES *UL Horizontal Load Ratings for all sizes Sch. 10 thru 40= 2015# - *UL Horizontal Load Ratings for 1"thru 4"Sch. 7=655# �`. * UL Horizontal Load Ratings for 6"Sch.7=1500# *Visual inspection,proper installation when gage spring lays flat. r \ ORDERING-Part#,pipe size to be braced,brace pipe size and finish. Specific AFCON produces are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners.resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by.4FCOis AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-.a FCON products have been,or are used. 6/07 „..z."...„."-g/Fe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 • ATTACHMENT FITTING LOCKING (5) SIZE- I and 1 1/4 inch bracing pipe. Use in combination with 1 thru 8 inch AFCON sway brace assemblies. MATERIAL-Carbon Steel,Ductile Iron or S.S.(Type 304). FINISH-Plain,E.G.and H.D.G. LISTING/APPROVAL- COPS 203A-EX2625 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION-Structure attachment fitting of a sway brace assembly,consisting additionally of AFCON 001 thru 040 sway brace fitting and brace element forming a complete sway brace assembly. INSTALLATION- Per NFPA-13 .Listed for use with NFPA fastener tables. For installation on H-beam or steel web joist see AFCON 085 thru 088 sway brace adapters. ASSEMBLY- Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. FEATURES *UL Horizontal Load Rating:2015#,All Sizes * Swivel design allows attachment at any angle. *Visual inspection,proper installation when set bolt head contacts bracket. * 17/32”Fastener hole,larger hole available.-Consult factory. ORDERING-Part#,pipe size and finish. Specific AFCON products arc exclusively designed to be compwttiblc ONLY with other.4 FCON products including parts and thsteners.resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCONwill NOT warrant against the failure of its products when used in combination with other products.pans or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever lime any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 2/07 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING If; Part#077 Q vt- Part#078 Part#410 — SIZE- 1 thru 8 inch pipe. MATERIAL-Carbon Steel or S.S.(Type 304). FINISH-Plain,E.G.,and H.D.G. LISTING/APPROVAL- e"tus 203A-EX 2625,203-EX 2551 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION-Pipe attachment component of a longitudinal or 4-way sway brace, consisting additionally ofAFCON 70 series attachment end, AFCON 80 series adapter as required and brace pipe element forming a complete sway brace assembly. INSTALLATION- Per NFPA-13.Assemble 410 over pipe to be braced, install 70 series attachment end on outside of clamp ears and tighten bolts to minimum required torque of 40 ft.lbs. 078 is the peferred assembly component for use with the 410-see drawing. FEATURES *UL Horizontal Load Rating: 1-3 pipe size=500# 4-8 pipe size=2015# *Made with 1/2"bolts to conform with sway brace fittings. ORDERING-Part#,pipe size and finish. Specific ICON products arc exclusively designed to be compatible ONLY with other.IFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hunger assembly. Re advised the following warranty restriction will apply.DISCLAIMER- FCON will NOT warrant against the failure of its products when used in combination with other products.parts or systems nut manufactured or sold by AFCON.AFCON slwll NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 2/07 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 079 4-WAY SWAY BRACE ATTACHMENT (DO I I I 10))16 1ST SIZE- 1"x 1", 1 1/4"x 1", 1 1/4"x 1 1/4" Use with I thru 8 inch AFCON sway brace assemblies. MATERIAL-Carbon Steel. FINISH-Plain,E.G.and H.D.G. LISTING/APPROVAL- eQ, 203A-EX 2625 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION-4-way sway brace assembly component for use on risers and other vertical piping configurations. INSTALLATION-Locate at 3"MAXIMUM distance from pipe being braced. Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * UL Horizontal Load Rating:2015#,All Sizes. * Visual inspection,proper installation when set bolt head contacts bracket. ORDERING-Part#,size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including pans and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. lie advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products.pans or systems not manufactured or sold by AFCON.AFCOA'shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have bent.or arc used. 2/07 `'—� P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 085 SWAY BRACE ADAPTER Radius-Tapped 1/2"orrice Nil , Part 13 100 \11414Suni-adi SIZE- 1/2"stud. pane • MATERIAL- Carbon Steel. FINISH-Plain or E.G. PATENT-No.6,749,359 LISTING/APPROVAL- c Ous 203A-EX 2625,203-EX 2551 LISTED Listed only for use with other AFCON bracing products. OSHPD OPA-0601-07 See Website. FUNCTION- Sway brace adapter for an AFCON sway brace assembly. Designed to stabilize a 1/2"stud in the chord space of a steel structural member. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Additionally listed as an 8"hanger attachment. INSTALLATION-Per NFPA 13 and these instructions. Load rating-see chart. Combine with proper AFCON components. The structural members design will dictate specific attachment criteria. Horizontal Load Ratings UL ASSEMBLY-See drawing. 9 Insert 1/2"threaded stud thru chord space into tapped part B. Install part A over Parallel 30°thru 90° 2015 stud,engage AFCON sway brace assembly and nut. Engage mounting nut finger Perpendicular 30°thru 90° 2015 tight,then additionally tighten 1 1/2 turns or torque to 40 ft.Lbs. *Stud and nut furnished by customer FEATURES * Radius-Tapped 1/2"orifice facilitates thread engagement. ORDERING- Part#and finish. Specific AFCON products arc exclusively designed to be compatible ONLY with other AFCON products including parks and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind.including but not limited to loss of business or profit,when non-A FCON products have been.or arc used. 6/10 I P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org • .087 • SWAY BRACE ADAPTER 6' Maximum 1n• ,411,,„,„„ � i on ■111111110 Pr ' 410 SIZE- 1/2"bolt. :� Tr. MATERIAL-Carbon Steel or Ductile(Pictured). r FINISH-Plain or E.G. PATENT-No.6,629,678. LISTING/APPROVAL- c Clus 203A-EX 2625,203-EX 2551 USTED FM FM Approved-1950 OSHPD OPA-0601 See Website. FUNCTION-Sway brace adapter for an AFCON sway brace assembly. Designed to attach to the vertical or horizontal flange of a steel structural member. Sway brace assemblies are intended to be installed in accordance with NFPA 13 • i and the manufacturer's installation instructions. Additionally listed as an 6"hanger attachment. . INSTALLATION-Per NFPA 13 and these instructions. Load rating-see chart. Combine with proper AFCON components-see disclaimer below. The structural members design will dictate specific attachment criteria. 087D Horizontal Load Ratings c s FM ASSEMBLY- See drawing. Parallel 30°thru 90° Install set bolts finger tight,then additionally tighten 1/2 turn or torque to125 inch 2765 3250 pounds. Attach AFCON sway brace assembly with 1/2"bolt. Perpendicular 300 thru 90° 2765 4500 FEATURES * Design conforms to angular geometry at panel point. * Fits 1/2" max.flange thickness. 087S Horizontal Load Ratings c Ouu ORDERING-Part#and finish. Parallel 30°thru 90° 2p 5 Perpendicular 30°thru 90° 2015 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners.resulting in a listed sway brace.restrainer or hanger assembly. Re advised the following warranty restriction will apply.DISCI.AIMIER-..I FCON will NOT warrant against the Iitilurc of its products when used in combination with other products,parts or systems not manufactured or sold by.IFCO.Y.:I FCON.shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-..IFCON products have been,or arc used. 9/11 tqcu I Fire & Building Products Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 Series TY-B — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be Description consulted with respect to the suitability _ _ of these coatings for any given corro- - _ The Series TY-B, 2.8, 5.6, and 8.0 sive environment.The effects of ambi- K-factor, Upright and Pendent Sprin- ent temperature, concentration of I i� ' klers described in this data sheet are chemicals, and gas/chemical velocity, - -- 1 standard response - standard cover- should be considered, as a minimum, age,decorative 5 mm glass bulb type along with the corrosive nature of the spray sprinklers designed for use in chemical to which the sprinklers will be `" light, ordinary, or extra hazard, corn- exposed. - mercial occupancies such as banks, _ ?�, hotelhotel chemical shopping malls,factories,refin An intermediate level version of the h chemical plants, etc. Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY B The recessed version of the Series Pendent Sprinkler in combination with �� TY B Pendent Sprinkler, where appli- the Model S2 Shield. cable,is intended for use in areas with _ - a finished ceiling. It uses a two-piece WARNINGS '--- Style 10(1/2 inch NPT)or Style 40(3/4 The Series TY-B Sprinklers described inch NPT)Recessed Escutcheon.The herein must be installed and main- Recessed Escutcheon provides 1/2 tained in compliance with this docu- 1 inch (12,7 mm) of recessed adjust- ment, as well as with the applicable 4 J J ment or up to 3/4 inch (19,1 mm) of standards of the National Fire Protec- 4.- ,#,s//// total adjustment from the flush pen- tion Association, in addition to the :- a` 1::..../ dent position.The adjustment provided standards of any other authorities hav- by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may the accuracy to which the fixed pipe impair the performance of these de- --f..1,, drops to the sprinklers must be cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler tained when exposed to corrosive at- manufacturer should be contacted - mospheres. Although corrosion resis- with any questions. tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies,the testing is Model/Sprinkler IMPORTANT Identification Always refer to Technical Data E Sheet TFP700 for the "INSTALLER °' WARNING" that provides cautions with respect to handling and instal- TY1151 - Upright 2.8K,1/2"NPT H lation of sprinkler systems and corn- TY1251 - Pendent 2.8K,1/2"NPT 2 ponents. Improper handling and in- TY3151 - Upright 5.6K,1/2"NPT 6 - stallation can permanently damage TY3251 - Pendent 5.6K,1/2"NPT a sprinkler system or its compo- TY4151 - Upright 8.0K,3/4"NPT Q nents and cause the sprinkler to fail TY4251 - Pendent 8.0K,3/4"NPT o to operate in a fire situation or cause TY4851 - Upright 8.0K,1/2"NPT a it to operate prematurely. TY4951 - Pendent 8.0K,1/2"NPT 4-- Page 1 of 8 JULY, 2004 TFP151 Page 2 of 8 TFP151 ESCUTCHEON 7/16"(11,1 mm) PLATE SEATING 1/2"** NOMINAL SSU* SURFACE NPT MAKE-IN DEFLECTOR _� f r-Ørpl'e T.--e S ?T!S*y"f"fa� 6 f N 5 ,Z; 2-1/4" 2-3/16" 4 • • (57,2 mm) =,' Il! (55,6 mm)i 2 1-9/16" ' WRENCH •��r Ili; 3(39,7 mm) FLATS 1 I 1 II SSP* 7 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16"(11,1 mm) STYLE 10 PLATE SEATING ** NOMINAL RECESSED - SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR } i//l/ mk /,n1Tn`*f/ [:\ 6* ■ -- uu ( 7/16"mm) 5 2 3/16" 11,1 mm (55,6 mm) 1�1 i NOMINAL I I 4 MAKE-IN 1-1/2" ilk� 2 3/16" r 2 (38,1 mm) � r I j (55,6 mm) 0 I, s i WRENCH __ l ,YY� f� 3���r- ���_ FLATS = 1 ` 7 J 1 SSP DEFLECTOR* 2-7/8'(73,0 mm)DIA. —•--I 1/2"NPT** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT TFP151 Page 3 of S • ESCUTCHEON 1/2"(12,7 mm) STYLE 40 PLATE SEATING ** NOMINAL RECESSED SURFACE NFT MAKE-IN ESCUTCHEON DEFLECTOR 6* Ill 1/2" 12; 5 2-5/16" 1 - (12,7 mm) (58,7 mm) j �j/��l � 7 NOMINAL i I 4 - � MAKE-IN 1-9/16" 1 ��� II 2-1/4" 11, 2 (39,7 mm) I J� (57,2 mm)WRENCH 3 1 ---° °-.. ---.-- FLATS rj ' SSP DEFLECTOR* - 2-7/8"(73,0 mm)DIA. - -I 3/4"NPT** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression 7-Ejection orifice seat on frame. Screw Spring **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT ESCUTCHEON 7/16"(11,1 mm) PLATE SEATING ** NOMINAL SSU* SURFACE NPT MAKE-IN DEFLECTOR * 6 ° ;Pi'r 111 't 1 ;;''7T '*`!TTS, 3 5 2-1/4' 1 2-3/16" , (57,2 mm) dI=U� ' (55,6 mm) ! I 4 l 1-9/16" WRENCH II-IP'' QL�\ ,±0 2 (39,7 mm) 1IusIr FLATS 7 Y I f► I 3 SSP* 1 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw - **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Page 4 of 8 TFP151 SPRINKLER FINISH(See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135°F/57°C Orange PENDENT 155°F/68°C Red 2.8 (TY1251) 1,2,3 N/A 1/2" • and 175°F/79°C Yellow NPT UPRIGHT P00°F/93°C Green (TY1151) 286°F/141°C Blue 360°F/182°C Mauve 1,2 135°F/57°C Orange PENDENT 155°F/68°C Red (TY3251) 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 and 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3151) 286°F/141°C Blue 1",2",3" 5" I 1"' 2",3",5"' 1/2" NPT 360°F/182°C Mauve I N/A 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1,2,3,4,5 1,2,4,5 N/A (TY3251)" 175°F/79°C Yellow Figure 4 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4251) 1,2,5 1,2,3,5 1,2,5 and 175°F/79°C Yellow 1,2,3,4,5,6,7 8 0 UPRIGHT 200°F/93°C Green (TY4151) 286°F/141°C Blue 1",2",3" 5"1 1",2" 5" NPT 360°F/182°C Mauve I N/A 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1,2,3,4,5 N/A (TY4251)" 175°F/79°C Yellow Figure 5 200°F/93°C Green 135°F/57°C Orange PENDENT '155°F/68°C Red 8.0 (TY4951) 1/2" and 175°F/79°C Yellow 1,2,3,5 N/A NPT UPRIGHT 200°F/93°C Green (TY4851) 286°F/141°C Blue 360°F/182°C Mauve NOTES: 1.Listed by Underwriters Laboratories,Inc.(UL). 2.Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3.Approved by Factory Mutual Research Corporation(FM). 4.Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03). 5.Approved by the City of New York under MEA 354-01-E. 6.VdS Approved(For details contact Tyco Fire&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377). 7.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05). 8.Where Polyester Coated,Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "150°F/66°C Maximum Ceiling Temperature. ""Frame and deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 .. 2-7/8"DIA. G, 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) WRENCH RECESS ND`A'uSED FOR FACE OF (57,2 mm) " 1 MOUNTING (E 2"NPT MODELS) SPRINKLER I PLATE '-"1 FITTING 1/8" WRENCH RECESS •�' (3,2 mm) (END"B"USED FOR G1���I 3/4'NPT MODELS) i ?1FIGURE 7 o�� W-TYPE 6 SPRINKLER WRENCH MOUNTING SURFACE WRENCH CLOSURE SERIES 1-1/4"(31,8 mm) RECESS TY-B 3/4"(19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT N.`�, PUSH WRENCH INTO ENSURE 2-7/8"DIA. ENGAGEMENT (73,0 mm) 3/4"(19,1 mm) WITH SPRINKLER 5/8±1/4" WRENCHING AREA (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (57,2 mm) FIGURE 8 FACE OF MOUNTING W-TYPE 7 RECESSED SPRINKLER PLATE SPRINKLER WRENCH FITTING 1/8" �fJ (3,2 mm) 11—..=_-.... / A ■ i MOUNTING �: SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) TY-B 13/16"(20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT Page 6 of 8 TFP151 ing the wax coating. Before wrench Technical Installation tightening the sprinkler,the jaws of the wrench are to be adjusted to just con- Data The Series TY-B Sprinklers must be tact the sprinkler wrench flats. After installed in accordance with the follow- wrench tightening the sprinkler,loosen Approvals ing instructions: the wrench jaws before removing the UL and C-UL Listed. wrench. FM, LPCB,VdS,and NYC Approved. NOTES • (Refer to Table A for complete approval Do not install any bulb type sprinkler if After installation,the sprinkler wrench • information including corrosion resis- the bulb is cracked or there is a loss of flats and frame arms must be in tant status.) liquid from the bulb. With the sprinkler spected and the wax coating re- held horizontally, a small air bubble touched(repaired)whenever the coat- Maximum Working Pressure should be present. The diameter of the ing has been damaged and bare metal 175 psi (12,1 bar) air bubble is approximately 1/16 inch is exposed. The wax coating on the Discharge Coefficient (1,6 mm) for the 135°F/57°C to 3/32 wrench flats can be retouched by gen- K=2.8 GPM/psi1/2(40,3 LPM/barl/2) inch (2,4 mm) for the 360°F/182°C tly applying a heated 1/8 inch diameter K=5.6 GPM/psi1/2(80,6 LPM/barl/2) temperature ratings. steel rod to the areas of wax that have K=8.0 GPM/psi1/2(115,2 LPM/bare/2) been damaged,to smooth it back over A leak tight 1/2 inch NPT sprinkler joint areas where bare metal is exposed. Temperature Ratings should be obtained with a torque of 7 Refer to Table A to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- NOTES Finishes mum of 21 ft. lbs. (28,5 Nm)of torque Only retouching of the waxcoatingap- Sprinkler:Reessed Escutcheon:White may be used to install sprinklers with plied to the wrench flats and frame Coated, Chrome Plated, or Brass 1/2 NPT connections. A leak tight 3/4 arms is permitted, and the retouching Plated inch NPT sprinkler joint should be ob- is to be performed only at the time of tamed with a torque of 10 to 20 ft.lbs. the initial sprinkler installation. Physical Characteristics (13,4 t 0 26,8 Nm). A maximum of 30 The steel rod should be heated only to Frame Bronze ft.lbs. 4 7 Nm)of torque is to be used y Button Brass/Copper to install sprinklers with 3/4 NPT con- the point at which it can begin to melt Sealing Assembly nections. Higher levels of torque may the wax, and appropriate precautions Beryllium Nickel w/Teflont distort the sprinkler inlet and cause need to be taken, when handling the Bulb Glass leakage or impairment of the sprinkler. heated rod, in order to prevent the Compression Screw Bronze installer from being burned. Deflector Co Do not attempt to make-up for insuffi- pp er cient adjustment in the escutcheon If attempts to retouch the wax coating Bushing (K=2.8) Bronze plate by under- or over tightening the with complete coverage are unsuc- sprinkler. Readjust the position of the cessful,additional wax can be ordered sprinkler fitting to suit. in the form of a wax stick(the end of Operation The Series TY-B Pendent and Up- which is color coded). Only the correct color coded wax is to be used, and right Sprinklers must be installed in retouching of wrench flats and frame The glass Bulb contains a fluid which accordance with the following instruc- arms is only permitted at the time of expands when exposed to heat.When tions. initial sprinkler installation. With the the rated temperature is reached, the steel rod heated as installation. With de- fluid expands sufficiently to shatter the Step 1. Pendent sprinklers are to be previously glass Bulb, allowing the sprinkler to installed in the pendent position, and scribed, touch the rod to the area re activate and water to flow. upright sprinklers are to be installed in quiring additional wax with the rod an the upright position. gled downward, and then touch the wax stick to the rod approximately Design Step 2. With pipe thread sealant ap- half inch away from the area re- plied to the pipe threads, hand tighten quiring retouching. The wax will melt Criteria the sprinkler into the sprinkler fitting. and run down onto the sprinkler. Step 3. Tighten the sprinkler into the The Series TY-B Pendent and Upright sprinkler fitting using only the W-Type The Series TY-B Recessed Pendent Sprinklers are intended for fire protec- 6 Sprinkler Wrench (Ref. Figure 7), Sprinklers must be installed in ac- tion systems designed in accordance except that an 8 or 10 inch adjustable cordance with the following instruc- with the standard installation rules rec- Crescent wrench is to be used for wax tions. ognized by the applicable Listing or coated sprinklers. With reference to Step A. After installing the Style 10 or ' Approval agency (e.g., UL Listing is Figures 1, 2, 3, and 4 the W-Type 7 p g y based on the requirements of NFPA Sprinkler Wrench or the adjustable 40 Mounting Plate,as applicable,over 13, and FM Approval is based on the Crescent wrench, as applicable is to the sprinkler threads and with pipe requirements of FM's Loss Prevention be applied to the wrench flats. thread sealant applied to the pipe Data Sheets).Only the Style 10 or 40 threads,hand tighten the sprinkler into Recessed Escutcheon, as applicable, When installing wax coated sprinklers the sprinkler fitting. - is to be used for recessed pendent with the adjustable Crescent wrench, Step B.Tighten the sprinkler into the installations. additional care needs to be exercised sprinkler fitting using only the W-Type to prevent damage to the wax coating 7 Recessed S rinkler Wrench (Ref. on the sprinkler wrench flats or frame P arms and, consequently, exposure of Figure 8).With reference to Figure 3 or bare metal to the corrosive environ 4 the W-Type 7 Recessed Sprinkler merit.The jaws of the wrench should Wrench is to be applied to the sprinkler be opened sufficiently wide to pass wrench flats. over the wrench flats without damag- Step C. After the ceiling has been in- TFP151 Page 7 of 8 stalled or the finish coat has been ap- The owner is responsible for the in- ,/ plied, slide on the Style 10 or 40 Clo- spection, testing, and maintenance of Limited sure over the Series TY-B Sprinkler their fire protection system and de- and push the Closure over the Mount- vices in compliance with this docu- Warranty ing Plate until its flange comes in con- ment, as well as with the applicable tact with the ceiling. standards of the National Fire Protec- Products manufactured by Tyco Fire and tion Association (e.g., NFPA 25), in Products are warranted solely to the • CCare anu addition to the standards of any other original Buyer for ten (10) years are authorities having jurisdiction.The in- against defects in material and work- stalling contractor or sprinkler manu- facturer manship when paid for and properly Maintenance should be contacted relative to installed and maintained under normal The Series TY B Sprinklers must be any questions. use and service.This warranty will ex- The It is recommended that automatic pire ten (10) years from date of ship- maintained and serviced in accord- ment by Tyco Fire Products. No war- ance with the following instructions: sprinkler systems be inspected, ranty is given for products or tested, and maintained by a qualified components manufactured by compa- NOTES Inspection Service in accordance with Hies not affiliated by ownership with Before closing a fire protection system local requirements and/or national Tyco Fire Products or for products and main control valve for maintenance codes. components which have been subject work on the fire protection system that to misuse,improper installation,corro- it controls,permission to shut down the sion,or which have not been installed, affected fire protection system must be maintained,modified or repaired in ac- obtained from the proper authorities cordance with applicable Standards of and all personnel who may be affected the National Fire Protection Associa- by this action must be notified. tion,and/or the standards of any other Absence of an escutcheon, which is Authorities Having Jurisdiction. Mate- used to cover a clearance hole, may vials found by Tyco Fire Products to be delay the time to sprinkler operation in defective shall be either repaired or a fire situation. replaced, at Tyco Fire Products' sole option.Tyco Fire Products neither as- Sprinklers that are found to be leaking sumes, nor authorizes any person to or exhibiting visible signs of corrosion assume for it, any other obligation in must be replaced. connection with the sale of products or Automatic sprinklers must never be parts of products. Tyco Fire Products painted, plated, coated or otherwise shall not be responsible for sprinkler - altered after leaving the factory.Modi- system design errors or inaccurate or fied sprinklers must be replaced. incomplete information supplied by Sprinklers that have been exposed to Buyer or Buyer's representatives. corrosive products of combustion, but IN NO EVENT SHALL TYCO FIRE have not operated,should be replaced PRODUCTS BE LIABLE, IN CON- if they cannot be completely cleaned TRACT,TORT,STRICT LIABILITY OR by wiping the sprinkler with a cloth or UNDER ANY OTHER LEGAL THE- by brushing it with a soft bristle brush. ORY, FOR INCIDENTAL, INDIRECT, Care must be exercised to avoid dam- SPECIAL OR CONSEQUENTIAL age to the sprinklers - before, during, DAMAGES, INCLUDING BUT NOT and after installation. Sprinklers dam- LIMITED TO LABOR CHARGES, RE aged by dropping, striking, wrench GARDLESS OF WHETHER TYCO twist/slippage, or the like, must be re- FIRE PRODUCTS WAS INFORMED placed.Also,replace any sprinkler that ABOUT THE POSSIBILITY OF SUCH has a cracked bulb or that has lost DAMAGES, AND IN NO EVENT liquid from its bulb. (Ref. Installation SHALL TYCO FIRE PRODUCTS' LI- Section). ABILITY EXCEED AN AMOUNT • EQUAL TO THE SALES PRICE. Frequent visual inspections are rec- ommended to be initially performed for MADE IN LIEU OF ANY AND ALL corrosion resistant coated sprinklers, OTHER WARRANTIES EXPRESS OR after the installation has been com IMPLIED.INCLUDING WARRANTIES pleted,to verify the integrity of the cor OF MERCHANTABILITY AND FIT- rosion resistant coating. Thereafter, NESS FOR A PARTICULAR PUR- annual inspections per NFPA 25 POSE. should suffice;however, instead of in- _ specting from the floor level,a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. Page 8 of 8 TFP151 P/N 57 - XXX - X - XXX SPRINKLER TEMPERATURE MODEUSIN RATING 530 2.8K UPRIGHT(1/2'NPT) TY1151 1 NATURAL BRASS 135 135°F/57°C 531 2.8K PENDENT(1/2"NPT) TY1251 4 WHITE POLYESTER 155 155"F/68°C 570 5.6K UPRIGHT(1/2'NPT) TY3151 3 WHITE(RAL9010)' 175 175°F/79°C 571 5.6K PENDENT(1/2"NPT) TY3251 9 CHROME PLATED 200 200°F/93°C 590 8.0K UPRIGHT(3/4'NPT) TY4151 7 LEAD COATED 286 286°F/141°C 591 8.0K PENDENT(3/4"NPT) TY4251 6 WAX COATED 360 360°F/182°C 286°F/141°C MAX. 560 8.0K UPRIGHT(1/2"NPT) TY4851 8 WAX OVER LEAD 561 8.0K PENDENT(1/2"NPT) TY4951 286°F/141°C MAX. 'Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS Recessed Escutcheon: Wax Sticks: Ordering Specify:Style (specify) Recessed Es- (for retouching wrench damaged Procedure (spec fy)n with (specify finish), P/N wax coating) Specify: (Specify color) color coded • When placing an order,indicate the full 1/2' (15 mm) Wax Stick for retouching(specify tern- product name. Refer to the Price List Style 10 perature rating)temperature rated Se- for complete listing of Part Numbers. Chrome Plated P/N 56-701-9-010 ries TY B Sprinklers, P/N(specify). 1/2" (15 mm) Contact your local distributor for avail- style 10 Black for 135°F P/N 56-065-1-135 ability. White Color Red for 155°F P/N 56-065.1-155 Coated P/N 56-701-4-010 Yellow for 175°F P/N 56-065-1-175 1/2' (15 mm) Blue for 200°F and Sprinkler Assemblies with NPT Style 10 Thread Connections: White RAL9010' P/N 56-701-3-010 286°F P/N 56-065-1-286 Specify: (Specify Model/SIN), Stand- 1/2" (15 mm) and Response, (specify K-factor), Style 10 NOTES Brass Plated P/N 56-701-2-010 Each wax stick is suitable for retouch- (specify temperature rating), Series 3/4' (20 mm) ing up to twenty-five sprinklers. TY-B (specify Pendent or Upright) Style 40 Sprinkler with(specify type of finish or Chrome Plated P/N 56-700-9-010 The wax used for 286°F sprinklers is coating), P/N(specify from Table B). 3/4 (20 m ) the same as for200°F sprinklers, and,40 White Color therefore,the 286°F sprinkler is limited Coated P/N 56-700-4-010 to the same maximum ceiling tempera- • 3/4' (20mm) ture as the 200°F sprinkler (i.e., Style 40 150°F). White RAL9010' P/N 56-700-3-010 3/4" (20 mm) Style 40 Brass Plated P/N 56-700-2-010 •Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Vico Fire & Building Products Technical Services:Tel: (800) 381-9312/Fax: (800)791-5500 Sprinkler Cabinets 3, 6, & 12 Sprinklers, 1/2 or 3/4 Inch NPT 6 ESFR Sprinklers, 3/4 or 1 Inch NPT General Description Tyco® Sprinkler Cabinets are con- structed of metal enclosures with hinged covers designed to provide on- site storage of an emergency supply of sprinklers and a sprinkler wrench. _ NFPA 13 requires a representative number of each type of sprinkler used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers {;:_. that may have operated or become damaged. Sprinkler Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate NPT threaded sprin- klers and are painted an attractive red enamel. WARNINGS Technical The Sprinkler Cabinets described here- Data in must be installed and maintained in compliance with this document, as Material well as with the applicable standards Carbon Steel of the National Fire Protection Asso- Weights ciation, in addition to the standards of any other authorities having jurisdic 3 Sprinkler Cabinet tion. Failure to do so may impair the 1 5 Lbs. (0,68 kg) performance of these devices. 6 Sprinkler Cabinet 2 3 Lbs.(1,04 kg) The owner is responsible for maintain- ,` i0 ing their fire protection system and de- 12 Sprinkler Cabinet ys-� vices in proper operating condition. 4 0 Lbs.(1,81 kg) 4 f4 '� The installing contractor or sprinkler 6 ESFR Sprinkler Cabinet should be contacted 3 3 Lbs.(1,36 kg) with any questions. Page 1 of 4 AUGUST, 2007 TFP785 Page 2 of 4 TFP785 • REMOVE KNOCKOUTS HOLES ACCOMMODATE TO ACCOMMODATE 1/2"NPT SPRINKLERS 3/4"NPT SPRINKLERS j 1 HINGES _PIM 1-5/16" 5-1/4"R • • (33,3 mm) (133,4 mm) 7-1/4" 1-1/4" DOOR SWING (184,2 mm) (31,8 mm) _____ 5" " 1-1/8" 'J (127,0 mm) (28,6 mm) iii 3-1/4" - 2" 2-5/8" 1-3/16" / 2-9/16" (98,4 mm) (50,8 mm) (66,7 mm) (30,2 mm) I j I (65,1 mm) I 6"(150 mm) MINIMUM / HOLES FOR . _i_ CLEARANCE 3/16"(5 mm) - I 0 5" SCREWS 1" (254 mm) (127,0 mm) 1-3/4" (44,5 mm) FARM� , 1 1 _ \ SPRINKLER SLOTS FOR WRENCH DOOR 1"(25,4 mm) AND HINGES SHELF STRAP HANGER SHELF NOT SHOWN FIGURE 1 3 SPRINKLER CABINET REMOVE KNOCKOUTS HOLES ACCOMMODATE TO ACCOMMODATE 1/2"NPT SPRINKLERS 3/4"NPT SPRINKLERS 1 HINGES it ,i \�;��) �•: Q 1 1 1 1 -5/16' 5-1/4'R (33,3 mm) (133,4 mm) 14-1/16" _ 1-1/4" DOOR SWING (357,2 mm) (31,8 mm) 10-13/16" 1-5/8" I] (274,6 mm) 1 x(41,3 mm) III 2" 6" I 1-3/16" 6"(150 mm) i 2-9/16" 3-1/4" (50,8 mm) ~ (152,4 mm) (30,2 mm) MINIMUM -r I x(65,1 mm) (98,4 mm) I I CLEARANCE I�I 1 / D I -1- 5,. (25,4 mm) (127,01 mm) y+-..-- 1-3/4' .1.11111111111111- \ (44,5 mm) _ 1i HOLES FOR SPRINKLER SLOTS FOR WRENCH DOOR 3/16"(5 mm) 1"(25,4 mm) AND HINGES SCREWS SHELF STRAP HANGER SHELF NOT SHOWN FIGURE 2 6 SPRINKLER CABINET TFP785 Page 3 of 4 • REMOVE KNOCKOUTS HOLES ACCOMMODATE TO ACCOMMODATE 1/2"NPT SPRINKLERS 3/4"NPT SPRINKLERS 1 1 I�,) r�)) It.y) IC O 'I" '' , 0 O • + L 1 1/2" •HINGES I !I_,.; 1∎,?) ':�?) .∎ Q Q (38,1 mm) ( 4 1-1/2" 5-1/4"R (38,1 mm) (133,4 mm) 14-1/16" 1-1/8" DOOR SWING (357,2 mm) (28,6 mm) ___ 10-13/16" 1-5/8" _ /7 l' (274,6 mm) (41,3 mm) 2" 6" 1-3/16" 6"(150 mm) 4-1/8" I I 3-1/4" (50,8 mm) (152,4 mm) (30,2 mm) MINIMUM // (104,8 mm) (98,4 mi m) j CLEARANCE // O 25,4 1" (127'0 mm) (44,5 mm) 1/.11111111 HOLES FOR SPRINKLER SLOTS FOR WRENCH DOOR 3/16"(5 mm) 1"(25,4 mm) AND HINGES SCREWS SHELF STRAP HANGER SHELF NOT SHOWN - FIGURE 3 12 SPRINKLER CABINET REMOVE KNOCKOUTS HOLES ACCOMMODATE TO ACCOMMODATE 3/4"NPT SPRINKLERS 1"NPT SPRINKLERS 1 1 HINGES -may-�)T��----e)I I, -?1 �\ C L 1-9/16" 6-7/16"R (39,7 mm) 1 (163,5 mm) ( ) DOOR SWING 14-1/16" 1-9/16" ---'--- (357,2 mm) (39,7 mm) I/ 10-13/16" 1-5/8" /� r (274,6 mm) I ~(41,3 mm) 2" 6" 1-3/16" 7"(180 mm) / 3-1/8" (50,8 mm) (152,4 mm) (30,2 mm) MINIMUM -1 L ,'/r (79,4 mm) 1 1 CLEARANCE 3-131 16" 0 I 1 (96,8 mm) 1" 6-3/16" (25,4 mm) (157,2 mm) 2-3/8" im ��_ 1 - (60,3 mm) HOLES FOR SPRINKLER SLOTS FOR WRENCH DOOR 3/16"(5 mm) 1"(25,4 mm) AND HINGES SCREWS SHELF STRAP HANGER SHELF NOT SHOWN FIGURE 4 6 ESFR SPRINKLER CABINET Page 4 of 4 TFP785 Installation Limited Ordering Sprinkler Cabinets are designed with Warranty Procedure two 3/16 Inch (4,7 mm)diameter holes for wall mounting or direct attachment Products manufactured by Tyco Fire When placing an order,indicate the full to the system riser with a strap-type & Building Products (TFBP) are war- product name. Contact your local dis- hanger. The Sprinkler Cabinet should ranted solely to the original Buyer for tributor for availability. be installed at or near the system con- ten(10)years against defects in mate- Sprinkler Cabinet: trol valve and must be stocked with an rial and workmanship when paid for Specify:(Description), P/N(specify). adequate supply of spare sprinklers and properly installed and maintained and a sprinkler wrench. under normal use and service. This 3 Sprinkler Cabinet P/N 1177 warranty will expire ten(10)years from 6 Sprinkler Cabinet P/N 1119 The stock of spare sprinklers should 12 Sprinkler Cabinet P/N 1124 include sprinklers of each type and date of shipment by TFBP. No warran 6 ESFR Sprinkler Cabinet P/N 1111 temperature rating as are installed in ty is given for products or components the sprinkler system, in the following manufactured by companies not of quantities: filiated by ownership with TFBP or for products and components which have Sprinklers In Spare re Sprinklers been subject to misuse, improper in- Sprinklers Required stallation,corrosion,or which have not been installed,maintained,modified or Under 300 6 repaired in accordance with applicable Standards of the National Fire Protec- 300-1000 12 tion Association, and/or the standards Over 1000 24 of any other Authorities Having Juris- diction.Materials found by TFBP to be defective shall be either repaired or re- The 3, 6, and 12 Sprinkler Cabinets placed, at TFBP's sole option. TFBP are designed to accept both 1/2&3/4 neither assumes, nor authorizes any Inch NPT threaded sprinklers, where- person to assume for it, any other ob- as the 6 ESFR Sprinkler Cabinets are ligation in connection with the sale of designed to accept both 3/4 & 1 Inch products or parts of products. TFBP • NPT threaded sprinklers. As neces- shall not be responsible for sprinkler - sary, insert a screwdriver blade from system design errors or inaccurate or - the front top of the shelf and under the incomplete information supplied by • near bottom part of the knockout an- Buyer or Buyer's representatives. nular ring. Press the screwdriver han- In no event shall TFBP be liable, in die down to remove the knockout ring. contract, tort, strict liability or under any other legal theory, for incidental, Care and indirect,special or consequential dam- ages,including but not limited to labor Maintenance charges, regardless of whether TFBP was informed about the possibility of The Sprinkler Cabinet, wrench, and such damages, and in no event shall stock of spare sprinklers should be in- TFBP's liability exceed an amount spected at least quarterly. The follow- equal to the sales price. ing items should be checked: The foregoing warranty is made in lieu •The Sprinkler Cabinet should be of any and all other warranties, ex- readily accessible, and not exposed press or implied, including warranties to a corrosive atmosphere or tem- of merchantability and fitness for a peratures in excess of 100°F(38°C). particular purpose. • •The stock of spare sprinklers should This limited warranty sets forth the ex- include an adequate number of each clusive remedy for claims based on type and temperature rating. failure of or defect in products,materi- - als or components, whether the claim •The stock of sprinklers must be in is made in contract, tort, strict liability good condition. or any other legal theory. •A sprinkler wrench of the appropriate This warranty will apply to the full ex- type must be included in the Sprin- tent permitted by law. The invalidity, kler Cabinet. in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 -- S'201L(— 00015 p 0 5 w r-F r>-'o RECEIVED JAN 3 0 2014 CITY OF TIGARD BUILDING DIVISION WATER SUPPLY INFORMATION TEST STATIC AT SRC: 120.0 PSI TEST RESIDUAL AT SRC: 96.0 PSI AT 2564 GPM INFORMATION DERIVED FROM A WATER REPORT SUPPLIED BY PACLAND DURING A FLOW TEST VISIT ON 12/21/11. THE TEST WAS CONDUCTED AT 11:00 A.M., PST AND WITNESSED BY HERB OHLER, TVWD CONSTRUCTION INSPECTOR. FLOW TEST ELEVATION: 196.0 FT AMSL BUILDING PAD ELEVATION: 180.0 FT AMSL THE WATER SUPPLY IS MODIFIED BY THE FOLLOWING: + 6.9 PSI DUE TO ELEVATION DIFFERENCE BETWEEN TEST AND BUILDING DESIGN STATIC AT SRC: 126.9 PSI DESIGN RESIDUAL AT SRC: 102.9 PSI AT 2564 GPM 3.0 PSI STATIC AND 5.0 PSI RESIDUAL PRESSURE LOSSES DUE TO 8" WILKINS 350ADA BACKFLOW PREVENTER ARE NOT INCLUDED. THE ADDITIONAL 5.0 PSI SAFETY FACTOR REQUIRED IS ALSO NOT INCLUDED. 4 . TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 HYDRAULIC DESIGN INFORMATION SHEET Job Name: TIGARD OUTLOT BULDING Location: SW DARTMOUTH RD & SW 72ND AVE TIGARD, OR 97223 Drawing Date: 1/2014 Remote Area Number: 1 Contractor: FIRESTOP COMPANY Telephone: (360) 718-8604 3203 NE 65th Street, #2 Vancouver, WA 98663 (360) 718-8603 fax Designer: Bob Knight, CET III, #100164 Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: UNOBSTRUCTED Occupancy:MERCANTILE Reviewing Authorities:DEPUTY FIRE MARSHAL SYSTEM DESIGN Code:NFPA 13 Hazard:OH 2 System Type:WET Area of Sprinkler Oper. 1612 sq ftl Sprinkler or Nozzle Density (gpm/sq ft) 0.200 I Make: TYCO Area per Sprinkler 130. 0 sq ftl Model: TY-B Hose Allowance Inside 0 gpm 1 K-Factor: 8. 00 Hose Allowance Outside 250 gpm ( Temperature Rating: 200 CALCULATION SUMMARY 15 Flowing Outlets gpm Required: 666. 6 psi Required: 85.4 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test Rated Capacity 0 gpm Static Pressure 126 . 9 psi Rated Pressure 0.0 psi Residual Pres 102 .9 psi Elevation 0 At a Flow of 2564 gpm Make: Elevation 0" Model: Location: SITE Source of Information: HENDERSON ENGINEERS SYSTEM VOLUME 189 Gallons Notes: GRID PEAKED CURRENT LOCATION REQUIRED 85.388 psi 666.61 gpm SHIFT LEFT(DOWN) REQUIRED 85.279 psi 668.37 gpm SHIFT RIGHT(UP) REQUIRED 85.211 psi 664 .23 gpm • TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref TR Required at Hyd Area 1 417 58.4 psi 1 Pipe 21" DFx21 DYNA FLOW 15 ' 120 2. 703 417 5.2 1 24"Butterfly Valve TYCO "BFV N" 9 ' 120 2. 469 417 5.0 1 24" Grvd Other Valve TYCO "513" 1 ' . 120 2 .469 417. 0. 7 1 Pipe 4" 10x21 Grvd 2 ' 120 4.260 417 0. 1 1 4" Grvd Check Valve CHART LOSS 417 0.0 Elevation Change 22 '5" 9. 7 Hydr Ref BR Required at BASE OF RISER 417 79.1 psi 1 Pipe 8" DI DUCTILE IRON 522 ' 140 8.390 417 0.6 3 8" MJ 90 Ell 54' 120 8.071 417 0. 1 1 8" MJ 45 Ell 9' 120 8.071 417 0.0 1 8" Flngd Gate Valve 4 ' 120 8.071 417 0.0 1 8" MJ Tee 35' 120 8.071 417 0. 1 Fixed Flow Outside Hose Allow. 250 gpm Hydr Ref U4 Required at 8" TO 8" 667 79.9 psi 1 Pipe 8" DI DUCTILE IRON 340' 140 8.390 667 0. 9 1 8" MJ Tee 35' 120 8.071 667 0.2 Hydr Ref U3 Required at 8" TO 8" 667 80.9 psi 1 Pipe 8" DI DUCTILE IRON 425' 140 8.390 667 1 . 1 1 8" MJ 45 Ell 9' 120 8.071 667 0.0 1 8" MJ Tee 35' 120 8.071 667 0.2 Hydr Ref U2 Required at 8" TO 8" 667 82 .2 psi 1 8" MJ 90 Ell 18 ' 120 8 .071 667 0. 1 1 8" Flngd Back Flow Valve WILKIN "35 CHART LOSS 667 2.7 1 8" Flngd Gate Valve 4 ' 120 8.071 667 0.0 1 Pipe 8" MJ DUCTILE IRON 155 ' 140 8.550 667 0. 4 Hydr Ref Ul Required at 8" TO 12" 667 85.3 psi 1 12" MJ 90 Ell 27' 120 11 .938 667 0.0 2 12" MJ 45 Ell 26 ' 120 11 .938 667 0.0 1 Pipe 12" MJ DUCTILE IRON 70 ' 140 12 .460 667 0 .0 Hydr Ref SRC Required at Source 667 85.4 psi Water Source126.9 psi static, 102.9 psi residual @ 2564 gpm 667 gpm 124 .9 psi SAFETY PRESSURE 39.5 psi Available Pressure of 124 . 9 psi Exceeds Required Pressure of 85.4 psi This is a safety margin of 39.5 psi or 32 % of Supply Maximum Water Velocity is 23 .5 fps Job Water Required Hose Allowance Pump Info Flow(gl TIGARD OLJTLQT SULDING Static Pressure: 126.9 psi Pressure: 85.4 psi Inside: 0 gpm Rated Pres: 0 psi SW DARTMOUTH RD &SW 72ND AVE Residual Pressure: 102.9 psi Systerh Flow: ` 417 gpm Outside: 250 gpm Rated Flow: 0 gpm TIGARD, OR 97223 Flow: 2564 gpm System+Hose: 667 gpm Remote Area: 1 Date: Safety Pres: 39.5 psi Loc:SITE Head Elev Pres: 58.4 psi 140 • Supply 120 100 • P 80 250 gpm hose 60 58.4 psi 40 20 150 225 300 375 450 525 600 675 750 Flow (gpm) TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90 ' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) P.t Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C) ^1.85 / ID^4 .87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Pn Normal pressure (psi) , where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0. 1 psi . Addition may vary by 0 . 1 psi due to accumulation of round off. - Calculations conform to NFPA 13 . - Velocity Pressures are not considered in these Calculations TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/ (PSI^') ) (PSI) (GPM) (GPM) (GPM/SQ.FT) 100 21 .37 8. 00 10.8 26.3 26.0 0.20 101 21 .37 8.00 10.6 26 .0 26.0 0.20 102 21 .37 8.00 10.6 26.0 26.0 0.20 103 21 .37 8.00 10. 7 26.1 26'.0 0.20 104 21 .37 8. 00 11 .2 26. 8 26.0 0.21 105 21 .81 8.00 12 .0 27. 7 26.0 0.21 106 21.81 8.00 11 .9 27.6 26.0 0.21 107 21 .81 8.00 11 . 9 27.6 26 .0 0.21 108 21 .81 8.00 12 . 4 28.2 26.0 0.22 109 22.24 8.00 12 . 1 27. 8 26.0 0.21 110 22 .24 8. 00 12 .0 27. 7 26.0 0.21 111 22.24 8.00 12. 0 27. 7 26.0 0.21 112 22 .24 8.00 12.5 28.3 26.0 0.22 113 22 .67 8.00 15 .2 31 .2 26.0 0.24 114 22 .67 8.00 15.5 31.5 26.0 0.24 Al 20. 12 31 . 7 A2 20. 56 31. 7 A3 21 . 00 32.0 -A4 21 . 42 32 . 7 A5 21 .86 34 .2 A6 22 .33 53 . 1 _B1 20. 12 14 . 4 B2 20. 56 14.3 B3 21 .00 14. 4 B4 21 . 42 15 . 7 B5 21 .86 16 . 1 B6 22.30 16 . 1 TR 22.33 58. 4 Max velocity of 23 .52 occurs in the pipe from A6 TO TR TIGARD OUTLOT BOLDING Drawing Date:1/2014 1/28/14 16:53 Tyco Fire Products Page 5 w!.e.w+a+.wr..}..x ..ywvm- >' .^L^s.-•.-r,F, -^_.»,.,..".T�.•e..,.,,.r,,,_. .....••,,.i.,._._ .F".^3^.»^._......-.-..x... v .w,.w,,,,,a,.:,,�,....,__r^.e^.......-..,-.n-•r ..._.....:_:_^.. _..aa.::��.,."3:7s'3�:c.:.A HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn ..:..,._..._.. =-rte._. _-=-rte==_,-.._.- _.._ PATH 1 FROM HYDRAULIC REFERENCE 102 TO TR (PRIMARY PATH) 17.59 1 .728 10.67 10.6 10.6 K. = 5.41 102 C=120 0.00 0. 0 0.0 17.59 0.009 10.67 0. 1 10.6 Vel = 2.43 26. 12 1 .728 12 .00 10.7 10.7 K = 8.00 103 C=120 0.00 0.0 0.0 43 .71 0.049 12.00 0.6 10.7 Vel = 6.04 26 .82 1 . 728 4E 124 .17 11 .2 11 .2 K = 8.00 104 C=120 2T 45. 16 0.5 0.0 70.53 0 .118 169.32 20.0 11 .2 Vel = 9.74 2. 703 10.01 31 . 7 31.7 Al C=120 0.00 -0.2 0.0 70.53 0.013 10.01 0.1 31 .7 Vel = 3 .98 68 . 12 2 .703 10.01 31 . 7 31 . 7 A2 C=120 0 .00 -0.2 0.0 See PATH 4 138.65 0.047 10. 01 0.5 31 .7 Vel = 7. 83 68. 49 2 . 703 9. 76 32 .0 32 .0 A3 C=120 0.00 -0.2 0.0 See PATH 6 207. 14 0 .098 9 . 76 1 .0 32 .0 Vel = 11 .69 63 .95 2.703 10.01 32 . 7 32.7 A4 C=120 0. 00 -0.2 0.0 See PATH 7 271 .09 0. 161 10.01 1 .6 32 . 7 Vel = 15.31 55.27 2 . 703 lE 75. 12 34.2 34.2 A5 C=120 9.33 -0.2 0.0 See PATH 9 326 .35 0.227 84.45 19 .2 34.2 Vel = 18 .43 90.26 2. 703 lE 5.46 53 . 1 53. 1 A6 C=120 9.33 0.0 0. 0 See PATH 2 416 .61 0.357 14. 78 5 . 3 53 . 1 Vel = 23.52 TR 416 .61 58. 4 K = 54 .53 PATH 2 FROM HYDRAULIC REFERENCE 102 TO A6 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 102 TO A6 CONTINUED 8. 41 1 . 728 8.67 10.6 10.6 K = 2 .59 102 C=120 0.00 0.0 0.0 8.41 0.002 8.67 0.0 10.6 Vel = 1 . 16 26.02 1 . 728 7.45 10.6 10.6 K = 8.00 101 C=120 0.00 0.0 0.0 34 .43 0.031 7.45 0.2 10.6 Vel = 4. 76 26 .31 1 . 728 2T 11 .50 10.8 10.8 K = 8.00 100 C=120 22.58 0.5 0.0 60.74 0.089 34.08 3.0 10. 8 Vel = 8.39 2. 703 10.01 14.4 14.4 B1 C=120 0.00 -0.2 0.0 60. 74 0.010 10. 01 0. 1 14.4 Vel = 3.43 42 .99 2 .703 10.01 14.3 14.3 B2 C=120 0.00 -0.2 0.0 See PATH 3 103 . 73 0.027 10.01 0.3 14.3 Vel = 5. 86 43 .01 2. 703 2E 10.96 14. 4 14.4 B3 C=120 18.65 -0.2 0.0 See PATH 5 146 .74 0 .052 29.61 1 .5 14. 4 Vel = 8.28 -1 .21 2. 703 10.01 15.7 15. 7 B4 C=120 0. 00 -0.2 0.0 See PATH 8 145.53 0. 051 10.01 0.5 15. 7 Vel = 8.22 -55.27 2 .703 10.01 16 . 1 16. 1 B5 C=120 0.00 -0.2 0.0 See PATH 9 90.26 0.021 10.01 0.2 16 .1 Vel = 5. 10 1 .728 8E 120. 12 16. 1 16 . 1 B6 C=120 3T 79.03 -0. 0 0.0 90.26 0. 186 199. 15 37 .0 16. 1 Vel = 12 . 47 A6 90.26 53. 1 K = 12.39 PATH 3 FROM HYDRAULIC REFERENCE 106 TO B2 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 106 TO B2 CONTINUED 15.31 1 .728 12 .00 11.9 11 .9 K = 4.44 106 C=120 0.00 0.0 0.0 15.31 0.007 12 .00 0. 1 11.9 Vel = 2 . 12 27.68 1 .728 2T 15 .62 12.0 12 .0 K = 8.00 105 C=120 22 .58 0.5 0.0 42 .99 0.047 38.20 1.8 12 .0 Vel = 5.94 B2 42 .99 14.3 K = 11 .36 PATH 4 FROM HYDRAULIC REFERENCE 106 TO A2 12 .27 1 . 728 10.67 11 . 9 11 .9 K = 3.56 106 C=120 0.00 0.0 0.0 12 .27 0.005 10.67 0.0 11 .9 Vel = 1 . 70 27.64 1 .728 12 .00 11 .9 11 .9 K = 8.00 107 C=120 0.00 0.0 0.0 39. 91 0.041 12.00 0.5 11 .9 Vel = 5.51 28 .21 1 . 728 4E 124. 17 12 . 4 12. 4 K = 8.00 108 C=120 2T 45. 16 0.5 0. 0 68. 12 0. 111 169.32 18. 7 12 . 4 Vel = 9. 41 A2 68. 12 31 .7 K = 12. 10 PATH 5 FROM HYDRAULIC REFERENCE 110 TO B3 15.24 1 . 728 12 .00 12 .0 12 .0 K = 4.40 110 C=120 0.00 0.0 0.0 15.24 0 .007 12 .00 0.1 12 .0 Vel = 2.10 27. 77 1 . 728 2T 15.62 12. 1 12 . 1 K = 8.00 109 C=120 22 .58 0.5 0.0 43 .01 0.047 38.20 1 .8 12 .1 Vel = 5.94 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) • TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 Tyco Fire Products Page 8 ▪ HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn B3 43.01 14. 4 K = 11 .34 PATH 6 FROM HYDRAULIC REFERENCE 110 TO A3 12 . 44 1 .728 10.67 12.0 12.0 K = 3 .60 110 C=120 0.00 0.0 0.0 12.44 0.005 10.67 0. 1 12 .0 Vel = 1. 72 27. 74 1.728 12.00 12.0 12.0 K = 8.00 111 C=120 0.00 0.0 0.0 40. 18 0.042 12.00 0.5 12 .0 Vel = 5.55 28.31 1.728 4E 124 . 17 12.5 12.5 K = 8.00 112 C=120 2T 45.16 0.5 0.0 68.49 0. 112 169.32 18.9 12 .5 Vel = 9.46 A3 68.49 32.0 K = 12.11 PATH 7 FROM HYDRAULIC REFERENCE 113 TO A4 32.41 1 . 728 12 .00 15.2 15.2 K = 8.31 113 C=120 0.00 0.0 0.0 32 . 41 0.028 12.00 0.3 15.2 Vel = 4. 48 31 .54 1 .728 4E 124. 17 15.5 15.5 K = 8.00 114 C=120 2T 45. 16 0.5 0.0 63.95 0.098 169.32 16 .6 15.5 Vel = 8.83 A4 63 .95 32. 7 K = 11 .18 PATH 8 FROM HYDRAULIC REFERENCE B4 TO 113 1 .21 1 .728 2T 37.08 15. 7 15 . 7 B4 C=120 22 .58 -0.5 0.0 See PATH 2 1 .21 0.000 59.66 0.0 15. 7 Vel = 0. 17 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) TIGARD OUTLOT BULDING Drawing Date:1/2014 1/28/14 16:53 Tyco Fire Products Page 9 • HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn _ T 113 1 .21 15.2 K = 0.31 C . �� _ __-__ I_. 22. 2_ _22___m_ _ 1 —_. . __ -• 4,..e,,.. —t _n_,.., _-�---�-- PATH 9 FROM HYDRAULIC REFERENCE B5 TO A5 55.27 1 .728 4E 173 .25 16 . 1 16 .1 B5 C=120 4T 67.74 -0.0 0.0 See PATH 2 55.27 0.075 240.99 18. 1 16 .1 Vel = 7.63 A5 55.27 34.2 K = 9.46 • UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) SEISMIC BRACING CALCULATIONS Sheet 1 of 3 Job Name:TIGARD OUTLOT BUILDINGS Job#:. Address:SW DARTMOUTH RD&SW 72ND AVE Contractor:FIRESTOP COMPANY TIGARD,OR 97223 Address: 3203 NE 65th Street,#2 Vancouver,WA 98663 Phone: (360)718-8604 Sway Brace Structural Fitting Information: Brace Information v Make: Model: Allowable Horz Load E f . Maximum Spacing 22 feet AFCON 77 Per Table 9.3.5.10.3 I Length of Brace 7-0 Rating: Adj per 9.3.5.10.3 Based on Angle(d) I Bracing Material 1"Sch 40 2015 lbs 1425 Divide Rated Load by B i Angle from Verticle 45-59 Sway Brace Pipe Fitting Information: 30-44 d/2.0 ii E is Least Rad.of Gyr. .421 Make: Model: 45-59 d/1.414 A gE P L/R Value 200 AFCON E 60-89 d/1.155 g 5 Max Horizontal Load 1310 Rating: Adj per 9.3.5.10.3 90 d/1 i i i Force Factor(Fp) 0.5042 2015 lbs 1425 r F Assembly Detail z Fastener Information Details Provided on Plan i i NFPA 13 Figure 9.3.5.9.1 & E n Orientation Angle B w I FASTENER s I Type Steel N/A 9 -1~'�BRACE Diameter 3/8 .5. 3 € Length(embedment) N/A • I g f g Max Load(bs)Steel 1200 FIGURE B f 11 I Max Load(bs)Wood N/A LOAD PERPENDICULAR !► 1 FASTEN LOAD TO UNDERSIDE '- 1i OF STRUCTURAL MENIEER rg Max Load(Ibs)Concrctc N/A g x E Pipe Pipe Pipe WEIGHT(Lb/F) Wp Net Brace Brace Identification on Plans g J a Size Type Length 4..,..,..... . Factor Tot.Wgt. Tot.Wgt. A 18 21/2 Sch 7 22 5.1 0.5042 56.57 Orientation of Brace 1 1/2 Sch 7 192 2.71 0.5042 262.35 LATERAL I 1 1 N/A N/A 0 0 0.5042 0.00 LATERAL BRACE INFO 1. P N/A N/A 0 0 0.5042 0.00 Table 9.3.5.3.2(a orb) - s N/A N/A 0 0 0.5042 0.00 Size&Sch i i N/A N/A 0 0 0.5042 0.00 of Pipe Braced s g N/A N/A 0 0 0.5042 0.00 2 1/2 Sch 7 a I 2 N/A N/A 0 0 0.5042 0.00 Max Length of Brace s g N/A N/A 0 0 0.5042 0.00 25 a e 3 N/A N/A 0 0 0.5042 0.00 Max Allowable Load(Ibs) ; 1 N/A N/A 0 0 0.5042 0.00 Table c - 1 N/A N/A 0 0 0.5042 0.00 Load 367 y g 4I Max Load per Table 9.3.5.3.2 367 Total Weight 318.92 TOTAL I. s Max Fastener Load 1200 Adjusted FR,/x 1.15(Ibs) 366.75 HORIZONTAL f t . i f; Max Structural Fitting Load 1425 LOAD A . Max Pipe Fitting Load 1425 p Adj Weight does not exceed MAX Allowable Loads Max Horizntal Brace Load 1310 . s Prepared by Bob Knight,CET III(NICET#100164) SEISMIC BRACING CALCULATIONS Sheet 2 of 3 Job Name: TIGARD OUTLOT BUILDINGS Job#:. Address: SW DARTMOUTH RD&SW 72ND AVE Contractor: FIRESTOP COMPANY TIGARD,OR 97223 Address: 3203 NE 65th Street,#2 Vancouver,WA 98663 Phone: (360)718-8604 Sway Brace Structural Fitting Information: Brace Information ,, Make: Model: Allowable Horz Load I 8 . Maximum Spacing 80 feet AFCON 77 Per Table 9.3.5.10.3 a Length of Brace 7-0 Rating: Adj per 9.3.5.10.3 Based on Angle(d) e Ti IS Bracing Material 1" Sch 40 2015 lbs 1425 Divide Rated Load by I I Angle from Verticle 45-59 Sway Brace Pipe Fitting Information: 30-44 d/2.0 2 s Least Rad.of Gyr. .421 Make: Model: 45-59 d/1.414 ° E L/R Value 200 AFCON 410 60-89 d/1.155 S Max Horizontal Load 1310 Rating: Adj per 9.3.5.10.3 90 d/1 Force Factor(Fp) 0.5042 2015 lbs 1425 >. F Fastener Information Assembly Detail a i Details Provided on Plan NFPA 13 Figure 9.3.5.9.1 3 a Orientation Angle H LL; FASTINER b g Type Steel NIA ? ,lirr..............I GRACE LL = a ? r Diameter 3/8 V may, • 9i Length(embedment) N/A 1 i Max Load(tbs)Steel 1035 FIGURE H 2 LOAD PARALLEL Max Load(Ibs)Wood N/A FASTENER INTO FACE OF STRUCTURAL MEMEER Max Load(Ibs)Concrete N/A 4 Pipe Pipe Pipe WEIGHT(LM/F) Wp Net Brace Brace Identification on Plans 3 a Size Type Length ...,,�,.,,,. Factor Tot.Wgt. Tot.Wg. B ? P 21/2 Sch 7 80 5.1 0.5042 205.71 Orientation of Brace I I N/A N/A o 0 0.5042 0.00 LONGITUDINAL 11 N/A N/A 0 0 0.5042 0.00 LATERAL BRACE INFO 1 ; a N/A N/A 0 0 0.5042 0.00 Table 9.3.5.3.2(a or b) g i N/A N/A 0 0 0.5042 0.00 Size&Sch i 5. F N/A N/A 0 0 0.5042 0.00 of Pipe Braced 1 i N/A N/A 0 0 0.5042 0.00 2 1/2 Sch 7 : a I Ile N/A N/A 0 0 0.5042 0.00 Max Length of Brace s z N/A N/A 0 0 0.5042 0.00 N/A a a a N/A N/A 0 0 0.5042 0.00 Max Allowable Load(lbs) g g N/A N/A 0 0 0.5042 0.00 Table N/A s N/A N/A 0 0 0.5042 0.00 Load N/A • 2 Max Load per Table 9.3.5.3.2 N/A Total Weight 205.71 TOTAL t Max Fastener Load 1035 Adjusted FP,,,)x 1.15(lbs) 236.57 HORIZONTAL a t ` Max Structural Fitting Load 1425 LOAD E P • Max Pipe Fitting Load 1425 Adj Weight does not exceed MAX Allowable Loads g Max Horizntal Brace Load 1310 a I Prepared by Bob Knight, CET III(NICET#100164) SEISMIC BRACING CALCULATIONS Sheet 3 of 3 _ Job Name:TIGARD OUTLOT BUILDINGS Job#:. • Address: SW DARTMOUTH RD&SW 72ND AVE Contractor: FIRESTOP COMPANY TIGARD,OR 97223 Address: 3203 NE 65th Street,#2 Vancouver,WA 98663 Phone: (360)718-8604 Per the available structural drawing information from sheet S0.02 for this project,the following data has been used to obtain the"Short Period Response Factor"for NFPA 13 Table 9.3.5.6.2: Occupancy Category= I • Importance Factor:I = 1.0 Site Class= D SDS= 0.705 SD1 = 0.390 Design Category= D The Following information has been obtained using the"U.S.Seismic"Design Maps"Web Application*." Conterminous 48 States Table 9.3.5.6.2 Seismic Coefficent Table 2005 ASCE 7 Standard Ss Cp Zip Code= 97223 0.33 or less 0.35 Spectral Response Accelerations Ss and S1 0.40 0.38 To interpolate between Cp values Ss and S1 =Mapped Spectral Acceleration Values 0.50 0.40 the following equation can be used: Data are based on a 0.05 deg grid spacing 0.60 0.42 Period Cenb-oid Sa 0.70 0.42 c =c, , • ,, • "` (s5 ss-low) s -s. , (sec) (g) 0.75 0.42 0.2 0.944 (Ss) 0.80 0.44 The Cp value for this project is: 1.0 0.340 (S1) 0.90 0.48 Cp= 0.5042 • Period Maximum Sa 0.95 0.50 (sec) (g) 1.00 0.51 Cp-low= 0.5 0.2 0.971 (Ss) 1.10 0.54 Cp-high= 0.51 1.0 0.347 (S1) 1.20 0.57 Ss= 0.971 Period Minimum Sa 1.25 0.58 Ss-low= 0.95 (sec) (g) 1.30 0.61 Ss-high= 1 0.2 0.907 (Ss) 1.40 0.65 1.0 0.334 (S1) 1.50 0.70 Cp=Seismic coefficient Value 1.60 0.75 Cp-low=next lower from table Conterminous 48 States 1.70 0.79 Cp-high=next higher from table 2005 ASCE 7 Standard 1.75 0.82 Ss=Spectral Response Zip Code= 97223 1.80 0.84 Ss-low=next lower from table Spectral Response Accelerations SDs and SD1 1.90 0.89 Ss-high=next higher from table SDs=2/3 x SMs and SD1 =2/3 x SM1 2.00 0.93 Site Class D 2.10 0.98 Period Centroid Sa 2.20 1.03 (sec) (g) 2.30 1.07 0.2 0.706 (SDs) 2.40 1.12 1.0 0.390 (SD1) 2.50 1.17 Period Maximum Sa 2.60 1.21 (sec) (g) 2.70 1.26 0.2 0.720 (SDs) 2.80 1.31 1.0 0.394 (SD1) 2.90 1.35 Period Minimum Sa 3.00 1.40 (sec) (g) 0.2 0.688 (SDs) 1.0 0.386 (SD1) Footnote: *Seismic design values outputted by this application are from the 200912006/200312000 International Building Code,the 2005/2002/1998 ASCE-7 Standard, and the 2003/2000/1997 NEHRP Recommended Provisions. Prepared by Bob Knight,CET III (NICET#100164)