Loading...
Report ZOi3-D612 FIRE ALARM CONTROL PANEL —7-700 r+rv\O h SILENT RECEIVED Model 5208 KNIGHT Al (1 2 8 2013 Fire Alarm Control Panel CITYOFTIGARD with Digital Communicator by Honeywell BIJILDINGDIVISION The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, Class A(Style D)or Class B (Style y, System 5ensoro, Gentex®, Faraday, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel • Clock source setting options for 50 :: �.•h • Event History Buffer(150 events) Hz, 60 Hz, or internal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2-or 4-wire detectors Specifications Operating Voltage: 24 VDC =� • 8 selectable/programmable output Primary AC: 120 Vrms 60Hz, 2A patterns for notification appliance @ circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: x t Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: �,a♦ relays Height: 24.75" (62.9 cm) • Programmable smoke verification, Width: 14.5"(36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8"protruding that can help minimize false alarms Overall Dimensions: SK-5208 • Programmable from the built-in Height: 26-3/8" (67 cm) control panel touchpad, remote Width: 17-3/16"(43.66 cm) • SKSS Downloading Software annunciator, or Windows®SKSS Total Depth: 4" (10.16 cm) • Plex-2 Door Option downloading software Operating Temp: 32°to 120° F Listings and Approvals • Direct connect port for on-site (0°to 49° C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing . CSFM Listed SKSS downloading software • Built-in walk test feature Optional Accessories • MEA approval 429-92-E Vol.XIII • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) while providing single button • 7181 Fire Zone Converter operation of the reset and silence • 5220 Direct Connect Module functions • 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module FIRE ALARM CONTROL PANEL .:k' .3 Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect -_ - - - For On-Site Programming 2 Class A (Style D) — � � � 1' or Class B (Style B)4— Initiation Circuits Programmable �E rx Form C Relays i .r 8 Class B (Style B) .— °. y` i 4_, Notification Initiation Circuits " " - Appliance Circuits i. t 5235 Remote 17:1• ,` - , Annunciators o L._ _di'�♦ SBUS Devices 5280, 5217, & 5824 To AC This document is not intended to be used for installation purposes.We try MADE IN AMERICA SILENT to keep our product information up-to-date and accurate.We cannot cover NI KNIGHT all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent FORM#350318 Rev C • Knight 12 Clintonville Road,Northford,CT 06472-1610 ©2010 Honeywell International Inc. by Honeywell Phone:(800)328-0103,Fax:(203)484-7118. www.silentknight.com • *Th, SYSTEM SENSORY Indoor Selectable- Output Strobes and Horn Strobes for • � j-g� a Ceiling Applications SpectrAlert®Advance audible visible notification products are rich with features guaranteed to cut installation times SPECTRIert and maximize profits. A N c Alarly Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela Like the entire SpectrAlert Advance product line,ceiling-mount • Field-selectable candela settings on ceiling units:15,15/75.30, strobes and horn strobes include a variety of features that increase 75,95, 110, 115, 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making Installations fast and foolproof while virtually eliminating • Universal mounting plate for ceiling units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING " � MEA LISTED .PPpovet approved stmt 771653'18 Indoor ..)125251165316 5(hmlll trmte., 54011(crimes.horn strobes.horns) 3023572 1.4EM52-05-E clime strobes) 55512(strobes) '1135-1653169(horns..:hors) SpectrAlert Advance Specifications Architect/EngineerSpeci€ications _ �.., _�,,..,_.,. General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- • gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products.when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95. 110,115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PhysicaUElectrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) • input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8-diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS, 6.9-diameter x 0.35-high(175 mm diameter x 9 mm high) TRCW-HS) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOS00501 • UL Current Draw Data ' UL-Mam-Strobe-Current Draw(mA HMS),. _ ' ----m.-- --.-- *-,:,.-... .w, _ ._.,----.-- -- ..,. 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR • Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00501 SpectrAlert Advance Dimensions • 6.8" 7,1- 2.25�{ Dia. Dia. illl s, ��' fro q\) i\ p o Id 7 : :� 2.5" J \\,....__________; 1 � � _ / .„..„.i .,s, Ceiling-mount horn strobes Ceiling back box skirt • SpectrAlert Advance Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R" 2-Wire Horn Strobe,Standard cd,Red SCR Strobe.Standard cd,Red PC2RH 2-Wire Horn Strobe,High cd,Red SCRH Strobe.High cd,Red PC2W"t 2-Wire Horn Strobe,Standard cd,White SCW* Strobe.Standard cd,White PC2WH' 2-Wire Horn Strobe,High cd,White SCWH Strobe.High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red Accessories PC4RH 4-Wire Horn Strobe,High cd,Red BBSC-2 Back Box Skirt,Ceiling,Red PC4W 4-Wire Horn Strobe,Standard cd,White Back Box Skirt,Ceiling,White TRC-HS Trim Ring,Ceiling,Red TRCW- Trim Ring,Ceiling,White HS Notes: •Add"-P"to model number for plain housing(no'FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. #"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings.'High cd"refers to strobes that include 135,150,177,and 185 candela settings. • TSYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 « 02012 syscem Sector. SENSOR` ie`,"� M°,Weal ,a" `. Phone:800-SENSOR2• 630 377-6495 '° E pa° "'°"°'"'inducing Me 3112 a"��nsheet Avosoosoi•3112 0--1 SYSTEM SENSOR Photoelectric Smoke Detectors a• System Sensor i3'"series smoke detectors represent '. i1 3 significant advancement in conventional detection. The i3 family is founded on three principles:installation �. ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire P detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof P detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings T 441; j) MEA MSFM ��� ,� • LISTED APPROVED ICI approved approved 5911 3011446 7272-1653:152 290-01-E 2093 3180932 (t3 Smoke Detector Specifications Ar chitecturallEngineerin gSpetifrcations„°° ”, .._° .A.„v �..... .,,. °_ Smoke detector shall be a System Sensor i3 Series model number ,listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 85 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 53 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 25%/ft nominal Input Terminals 14 to 22 AWG Mounting 31 -inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off ° Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal . Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 Product 50mA:wens anna to chomp 02009 m`"" Of SENSOR' Phone:800-SENSOR2•Fax 630-377-6495 anent pia°""'q'""OA inclining the Wiest O1°nd this daosheet 1105Q318{07.6A9-,7169 ,t • CONVENTIONAL FIRE CONTROL PANEL ACCESSORY PS-DA and PS-SA . �, .a Conventional Pull-stations 1, '�' a '' ` ° '' Easy to Install and Operate x s . w ; The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which q. r .i;" provide a Fire Alarm Control Panel (FACP) with a single alarm initiating - . . input signal. The PS-DAPS-SA pull stations includes both single-action and dual-action models equipped with key lock/ reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and mul- tiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate. Operation !�I■■�■■■■rt■■�......n The single-action pull-station is lb 4 ` activated by a single pull-down of !.•• ' �����t���� the alarm handle. The dual-action ! versions require pushing in the s,ACTIVA rE17o EMPUJEY handle, then pulling the handle PUSH t1.4 down for activation. The PS- :"..:-'• - • HA-E r!•iACIA ABR.K) DA/PS-SA manual pull stations are Pt.JSH IN PULL UL listed and meet the ADA y�� L DtD`''t requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. tt.t r I .w SIIEN.r. Molded terminal numbers can be °It.taT KNIGHT iTi found adjacent to the wiring termi- u ; . ,y .. *' 4 • nals. ill MAO ♦ w If Models: PS-DA PS-DASP PS-SA— Single action with `pigtail' connections and a key lock reset. PS-DASP — Same as PS-DA Specification: Pigtail wires are provided for con- except with both English and Spanish operating instructions. Dimensions: nection to the Fire Alarm Control Height: 5-1/2"(13.97 cm) Panel's (FACP) initiation circuit. Features: Width: a"(10.16 cm) Depth: 1-7/16"(3.65 cm) PS-DA — Dual action model with • UL Listed Operating screw terminal connections and a • CSFM Listed temperature: 32°F to 120°F key lock reset. (0°c to 49°C) • Meets ADA requirements PS-DAH — Same as PS-DA except • Operating instructions are mold- Electrical: with hex lock reset. Switch Contact ed into the handle along with Rating: 0.25 A @ 30 VAC PS-DALOB — Same as PS-DA with Braille text. or VDC "outdoor use" listing. Includes SB- • Made of durable Lexan Accessories: I/O backbox and sealing gasket. • Available in Spanish SB-I/0 Surface Mount ItiSILENT • Key resettable Back-box KNIGHT • Easy to Install and operate BG-TR Trim Ring by Hord Single or dual action • Surface mount box available - CONVENTIONAL FIRE CONTROL PANEL ACCESSORY PS-DA and PS-SA Conventional Pull-Stations + Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back-box SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO" on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. FIRE 3 t [ ... * I -�� :, . - I , ti , izi . . ,,.. . .. . , ;a�.t:ar � u_i�1 , , ti- - ,,, ;,,. W 2 ,ill'a PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA N KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are sub- P/N 350241 Rev. C Wav►+� ject to change without notice.For more information, contact Silent Knight 12 ©2009 Honeywell International Inc. Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.www.silentknight.com