Loading...
Specifications 210P2-0 I 2_-00 1 S S —7 Ie4p 3w SOr,c{ b 5 7650 S. W.Beveland St. TM RIPPEY Tigard,Oregon 97223 CONSULTING ENGINEERS Phone: (503)443-3900 Fax: 15031443-3700 STRUCTURAL CALCULATIONS PROJECT: McCORMACK STAIR INFILL LOCATION: TIGARD,OREGON CLIENT: MILDREN DESIGN GROUP DATE: JULY 19,2012 PROJECT NUMBER: 12286 TABLE OF CONTENTS: ITEM SHEET NUMBER GENERAL NOTES N1 LOWER LEVEL PLAN SK1 PARTIAL FRAMING PLAN SK2 SECTION AT BEARING WALL SK3 SECTION AT CONC.WALL SK4 CALCULATIONS C1-C2 41I0 PRPAN NS e'tro 15 ►4 1'�'isr'► V TU ir'9E3J GENERAL STRUCTURAL NOTES . CODE REQUIREMENTS: CONFORM TO THE 2009 INTERNATIONAL BUILDING CODE AS AMENDED BY THE 2010 OREGON STRUCTURAL SPECIALTY CODE,REFERENCED HEREAFTER AS IBC. DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE IBC. IN ADDITION TO THE DEAD LOADS,THE FOLLOWING LOADS WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER IBC: FLOOR LIVE LOAD: 50 PSF+ 15 PSF PARTITION LOAD EXISTING CONDITIONS: THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS,DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS PRIOR TO THE START OF THE WORK. TEMPORARY CONDITIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY OF THE NEW AND EXISTING STRUCTURES AND WALLS DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL CONFIGURATION ONLY. CARPENTRY: SAWN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION,LATEST EDITION. SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. UNLESS NOTED OTHERWISE ALL LUMBER SHALL HAVE A MAXIMUM MOISTURE CONTENT OF 19%AT TIME OF FABRICATION. ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR CMU SHALL BE PRESSURE TREATED UNLESS AN APPROVED BARRIER IS PROVIDED. GRADES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE • COMPANY(OR ENGINEER APPROVED EQUAL)AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND ATTACHED PER MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS UNLESS NOTED OTHERWISE. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL FRAMING NAILS SHALL BE COMMON NAILS. NO BOX NAILS ALLOWED. ALL FASTENERS IN CONTACT WITH FIRE RETARDENT LUMBER MUST BE HOT-DIPPED GALVANIZED. NAIL CALLOUTS SHALL BE INTERPRETED AS FOLLOWS: NAIL TYPE LENGTH DIAMETER 8d 2-1/2" 0.131" 10d 3" 0.148" I6d 3-1/2" 0.162" ALL SUB-FLOORING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS,EXCEPT AS INDICATED ON THE DRAWINGS. NAILING NOT SPECIFICALLY IDENTIFIED ON THE DRAWINGS SHALL CONFORM TO IBC TABLE 2304.9.1. 1 M K Consulting RIPFEY /�c_ ((•Z.avv„ ..L. 50c112-- By: 1�44ti- Date: 7650 SW Beveland Street Chic By: Date: Suite 100 Tigard,Oregon 97223 Job#: I Z1.9? ( Phone:(503)443-3900 Sheet: N( Of V — OFFICE I OM WORK i I i RO I OFFICE OFFICE = I r 1...... .... ..: �� � _ ` "e' [- III D l RECEPTION r IM CONFERENC WAITING A I u a V BREAK ROOM 1 b c E a ' IOFFICE OPEN OFFICE I L,_-___...,..... ..._, . — 1 ELEC/TELE FrRrh dF Warta.; FX1ST1a.l -1-h\ .S To i/ Fzn 1Ir:1" AND Ntia FL-c cD t2. F1ZN\1 N Ta csrL P,DT .t7 r J Tb MPTc.tt )?t.EV c1 Ot^ Mfr } cc v- L V'Et—. DEr t/sYZ.. Fz, FizhHAvJ c c=1.-h0J. i 1.---O WV-4- lot/ .L F V pt.J J sic( N1'I IL/11t \ TM RIPPEY �(�.�--0 v... l�k-e.,,\'— PCt cZ 5' (�� BY 1�ti1� DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St, Suite 100 JOB NO /ZZ`Y Tigard, Oregon 97223 Phone (503) 443-3900 SHEET l. OF I I I I I ❑ 1 _ ±i. . 1 . 1 2/7 WORK l OFFI'V E ROONT I : 0 til 1 4 x �} J ] `. CG) coNC. al \c;- . 'IC; II lb. 'WA. r (E) Z &Way (E) zxlZE P 24.-v 1 Pg. NEW R.Y vJooP FLQADR Hrac-rltiNi C, To ►■Kk!{ Mxts-i%rJ 6 f Tt► - ,"t p„ ,j }C"7— /ti N= P-T: `r 1MKTM RIPPEY L 5 11:t� BY ^2Vt^ DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St,Suite 100 y JOB LZ°3(<7 Tigard, Oregon 97223 Phone(503)443-3900 SHEET .t- OF Cry w+d.L ' i&co swiek-r 1-4146. (R) AlI i 041. ----\ Irs- NaV •14 7th1J( PV5 — Z1.•P.c•.1 m iris .�'— ��— • I li) F4cc�►Z. ----tp- 1 _ N ttw Tolc-t Pa rt-, 5c. ---( , \\\\ P.-J.0J 1 T -- -ov}.pF% 2 x Q)4c 1�:1 1.s G. 13X-[w a tz J F LcSc,)L. BTU I s--r5 C a) 2 h _gk x-114 L--'''' WkLL.. SI&s \c.a_ •--x\2 ToC,TN-Cc.2. Aer 1--+ P w I1-H- C3ti 'O h N!'c1.1— • l 1 '7- -T----- /61.) 31gk-R tJZ 3LCac.r\N� P- 'I w,-c.c_ TaP •'Lk---".c i- ._.'D , 5 l 3 (.,F0 IM-L s- ;,tip 0 it./....---t‘.0 sJ , 0 1 t(z., ^1,o ee //T� TM RIPPEY /V 1 e z�,r� 1� S Tr�\CZ. ,1 N F't t.1..•.., BY r`;,K DATE 1 x Z CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 IOB NO 12.7- G Tigard, Oregon 97223 SHEE7 \ OF Phone (503)443-3900 (NI\ F1s.)ocz, aizkill! (�) it -[�4\�s �.∎ l r , ,- ,. ' • i N6-w Ftc-oil s PER- PI-K+.1 i not +.1 i LhS210 r -*-- (E_) cflr u_. W 1`�i-_ Cam-) PD.. 2 x 1'1_ Ls.DU rs:12- • • _________Ar.--,--- S[zLT t a�a i� 6..0,,_,,..... , fin/?Kt-L.-. sk'( /'� lEAK TM RIPPEY /V G 652 M aC�5/.... J k\-2_, L/J Ft 1..-L- BY Ir g i< DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St, Suite 100 JOB NO'tI 222 . Tigard, Oregon 97223 SHEET \4 OF Phone(503) 443-3900 ^J�z`.� Fl coo Iz (3-015TS l('-o `` s • Pt" = Go Pew t IF:pcsmccwJ � -L 1c-, �G1�TS *'{ I t J ' INN= b P[_t=x 11• Z g _ I21 - � V Cam., 1 -1"' x ►1' LtO -z_ c, '-# •12 (ZC'c' /6, I 90f) rs� 2�O1 x = 22,5 x et7F k11 IG�Cx7o h v,ss M ' ' e'l� F6' = ciao Y s\ x 1,cD n 1.0 h 1,i S — IO3S Ps\ 4-f- Cr TM RIPPEY (.v(4,\)-- .-)":1/4-117... J-►-1 `I-L BY Cr2. — DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 SOB NO 122iM Tigard, Oregon 97223 SHEET Cl OF Phone (503)443-3900 Ntiw , e_) Scx�'c P V 7 go -.F x 4-115' - 3 Z '-1-1 HO 4 S D = 8 4jr- x x,3"5 '/-r c = 110(.,*- 11° / '� = (5-c) Ps3 x 110 I,IS x p, sr; - SS Ps■ �s s PSI 7 21\ wkL_ a - 4P f d �'IZ,r { I`I+ 4-6" n 1 = I t�1 3o /F1 / & zC I 1 G" 1M TM RIPPEY G C..«(4-Nn/CC-�- �k{- F'l�- BY k E k DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB NO /7-^S-VP Tigard, Oregon 97223 SHEET i - of Phone(503)443-3900