Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
INCITY OF TIGARD MASTER PERMIT g •• COMMUNITY DEVELOPMENT Permit#: MST2015 00056 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/15/2015 Parcel: 2S110BA11000 Jurisdiction: TIGARD Site address: 14092 SW 118TH CT Subdivision: MEDALLION MEADOWS Lot: 3 Project: Medallion Meadows, Lot 3 Project Description: New SF. Demo credits from BUP2014-00190 to be applied to this permit. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1761 st Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 22 Bathrooms: 4 Second: 1181 sf Garage: 585 sf Front: 20 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2942 sf Value: $364,760.58 Rear: 15 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 5 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 6 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add"500 sf: 6 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2942 Owner: Contractor: JT ROTH CONSTRUCTION INC J TROTH CONSTRUCTION Required Items and Reports(Conditions) FOUR D CONSTRUCTION CO 12600 SW 72ND AVE#200 1 Ersn Cntrl 503-639-4175 12600 SW 72ND AVE#200 TIGARD,OR 97223 TIGARD,OR 97223 PHONE: PHONE: 503-639-2639 FAX: 503-624-0239 Total Fees: $9,481.32 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. AT • • Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001 6010 through•'R• +1- 090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issue. By: Permittee Signature: //dr/it /et-- Call 503.639.4175 by 7:00 a.m.for the next available inspection dat . This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE 1_SE ON IA City of Tigard Received ,1 Date/By: `i Permit No. ]l S_ ■ 13125 SW Hall Blvd.,Tigard,OR 972296 `C I V E D Plan Aevte i Phone: 503.718.2439 Fax: 503.598.1 DateB . `. t Other Permit: 1.y -_ - -y 1 i I G A R D Inspection Line: 503.639.4175 Date Ready," r�rs luris Fd See Page 2 for Internet: www.tigard-or.gov APR 2 2 2015 Notified/Meth d: '1 7C Supplemental Information fly r !� TYPE OF WOI�c�TY OF TIGARDs, REQUIRED DATA:I-AND 2-FAMILY DWELLING A ®New construction UILDING DIV}SiON�t Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicateed on this application,./ Valuation. 1�! $5IS;f100 '3c4)7� t ® I-and 2-family dwelling ❑Commercial/industrial 4�� ❑Accessory building ❑Multi-family Number of bedrooms: 4 ❑Master builder ❑Other: Number of bathrooms: 3.5 NOV 9 r JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Job site address:11.40irr<r118th Court New dwelling area: 2,492 4square feetr -- City/State/ZIP:Tigard,OR 97224 Garage/carport area: 585 square feet Suite/bldg./apt.no.: Project name:Medallion Meadows Covered porch area: 150 square feet l(6,! Cross street/directions to job site:Gaarde Road to 118th Court Deck area: 219 square feet t74 Other structure area: 3,527 square feet 21:2_ REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Medallion Meadows Lot no.:03 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead.and the profit for the DESCRIPTION OF WORK work indicated on this application. Construction of new single family residence Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:J.T.Roth Construction Inc. Type of construction: Address: 12600 SW 72°d Ave. Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:(503)639-2639 Fax:(503)624-0239 New: ❑ APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* Business name:J.T.Roth Construction Inc. (Please rejerro fee schedule Structural plan review fee(or deposit): Contact name:David Jensen FLS plan review fee(if applicable): Address: 12600 SW 72e1 Ave. Total fees due upon application: City/State/ZIP:Tigard,OR 97223 Phone:(503)806-0602 Fax: :(503)624-0239 Amount received: E-mail:davidj(a jtrothinc.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:J.T.Roth Construction Inc. Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 12600 SW 7201 Ave. Solar Installation Specialty Code checklist. City/State/ZIP:Tigard,OR 97223 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)639-2639 Fax:(503)624-0239 State surcharge(12%of permit fee): $21.60 CCB lie.:31700 Total fee due upon application: I $201.60 Authorized signature: This permit application expires if a permit is not obtained / .-� within 180 days after it has been accepted as complete. Print name:David Jensen Date:04-14-2015 *Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits\BUP-RESPermitAI,.ioc 02/24/2011 440-4613T(I1/02/COM/WEB) • s Building Permit Application Checklist One- and Two-Family Dwelling tl►K (1f1 1( 1 1 .i ()NI 1 Received City of Tigard Re eive Permit No.: IIIII • 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits: ■ Phone: 503.718.2439 Fax: 503.598.1960 1 lc, \r l) 24-Hour Inspection Line: 503.639.4175 El Electrical ❑ Plumbing ❑ Mechanical Internet: www.tigard-or.gov ❑ Other: i 1IF: FOLLO\\ I\(. I"I F:\IS ARV REQ1 IRF,I) FOR I'L. \ RF:VIF:AN \I., \i, ` \ I Land use actions completed. See jurisdiction criteria for concurrent reviews. • • • 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. • 0 3 Verification of approved plat/lot. ❑ 0 4 Fire district approval required. Name of district: . ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ , ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. • I I Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑ ❑ ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator,lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑ furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑ floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ 0 ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 ❑ ❑ systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ ❑ A 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ 0 architect licensed in Ore on and shall be shown to be a licable to the ro'ect under review. 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x I I"or 11"x I7". 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑ 25 Buildingplans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ ❑ ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. 1:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) I , • ■ e Electrical Permit Application •nit()FIR I I til ()NI 1 City of Tigard Received RECEIVED �te� : Permit No.: !1'1 57;A...i S-4 _,. Illq 13125 SW Hall Blvd.,Tigard,OR Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Other Permit: 1 Inspection Line: 503.639.4175 APR 2 2 2015 Date Ready/By: 3uris: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF�CilHd' iI err© DTs PLAN REVIEW ®New construction ❑Addition/a4tlarZtloPmplacefllent Please check all that apply(submit a sets of plans w/items checked below): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF exceeds 10,000 amps at 150 volts or ❑Floating buildings. ® I-and 2-family dwelling less to ground,or exceeds 14,000 ❑Commercial-use agricultural y g ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or ,�SITE LOCATION ❑Emergency system. larger separately derived system. ❑Addition of new motor load of ❑"A","E","1-2","1-3", Job no.: Job site address:1 SW 1189[0 Court 1001TP or more. occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP:Tigard,OR 97224 lyo q 9- ❑Health-care facilities. 0 Supply voltage for more than ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: Project name:Medallion Meadows ❑Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site:Gaarde Road to 118th Ct. Description 1 tom. i Fee. ) Total I New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision:Medallion Meadows Lot no.:3 1.000 sq.ft.or less 1 1 168.54 4 Ea.add'l 500 sq.ft.or portion — 6 33.92 1 Tax map/parcel no.: Limited energy,residential 1 75.00 2 DESCRIPTION OF WORK (with above sq.ft.) Limited energy,multi-family 75.00 2 Wiring of new single family residence residential(with above sq.ft.) Renewable Energy ❑ See Page 2 Services or feeders installation,alteration,and/or relocation IS PROPERTY OWNER I ❑ TENANT 200 amps or less 100.70 2 201 amps to 400 amps 133.56 _ 2 Name:J.T.Roth Construction Inc. 401 amps to 600 amps 200.34 2 Address: 12600 SW 72ad Ave 601 amps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP:Tigard,OR 97223 Temporary services or feeders installation,alteration,and/or Phone:(503)639-2639 Fax:(503)624-0239 relocation 200 amps or less 59.36 1 Owner installation: This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration,or extension,per panel ci ArrucArrr I 0 CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, 7.42 2 Business name:J.T.Roth Construcion Inc. each branch circuit B.Fee for branch circuits without Contact name:David Jensen service or feeder fee,first 56.18 2 branch circuit Address: 12600 SW 72nd Ave. Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) City/State/ZIP:Tigard,OR 97223 Each manufactured or modular dwelling,service and/or feeder 67.84 2 Phone:(503)806-0602 Fax::(503)624-0239 Reconnect only 67.84 2 E-mail:davidj @jtrothinc.com Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:Dreamhouse Electric Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 2 Address: 13075 SW Canyon Road Each additional inspection over allowable in any of the above City/State/ZIP:Beaverton,OR 97005 Additional inspection(I hr min) 66.25/hr Investigation(1 hr min) 66.25/hr Phone:(503)648-5144 Fax:(503)648-9723 Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lie.: 196726 Electrical Lic.: C-848 Suprv.Lic.: specifically listed( :hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name: Chris Mahoney Date: 04/14/2015 Plan review(25%of permit fee): i � State surcharge(12%of permit fee): Authorized signature: r .09,7 --- TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Date: days after it has been accepted as complete. • Number of inspections allowed per permit. r\Building\Permits iELC_PcsmitApp_E1R_ERE.doc Rev 05/21/2013 440-4615T(11/05/COM/WEB r Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FILE SCHEDULE Fee for all residential systems combined $75.00 Description l Qty. I Fee I Total l • Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ® Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 ❑ Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 ® Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with 552.26 2 OAR 918-309-0040) ® Heating, Ventilation and Air Conditioning System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ® Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: Z Other: Landscaping Each additional inspection is charged at an hourly(I hr min) 6625!hr 1 Inspections for which no fee is 9000/hr specifically listed(%1 hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fee): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 ❑ Audio and Stereo Systems days after it has been accepted as compkte. ' Number of inspections allowed per permit. ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation n HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical n Nurse Calls n Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:1 Building\Permits&ELC_PermitApp_ELR_ERE.doe Rev 05/21/2013 1 P 1 Mechanical Permit Application lOR 01 1 1( I 1 ON1.1 Received City of Tigard e/B Permit No.: 3 -,• 1,5 13125 SW Hall Blvd.,Tigard,OR 9722 `I Plan Review I Phone: 503.718.2439 Fax: 503.598.19 EI.J Y ED Date/By: Other Permit: 1 [G R n Inspection Line: 503.639.4175 Date Read/B brie Page 2 for Internet: www.tigard-or.gov APR 2 2 2015 Notified/Method: SSupppllemenal Information TYPE OF WOI1'TY ot TIGAS DOS RCIAL FEE* SCHEDULE-USE C1 1ST ®New construction �NQ D{V Mechanical permit fees*are based on the value of the work ❑Addition/alter acement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:S CATEGORY OF CONSTRUCTKIN RESIDENTIAL EQUIPMENT/SYSTEMS FEES' ® I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For speda!Information use checklist. ❑Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total 6 qy JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address' I I8`s Ct. Furnace 100,000 BTU(ducts/vents) I 46.75 City/State/ZIP:Tigard,OR 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Heat plump 61.06 Suite/bldg./apt.no.: Project name:Medallion Meadows Duct work 23.32 Cross street/directions to job site:Gaarde Road to 188th Court Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision:Medallion Meadows Lot no.:03 Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater t 23.32 DESCRIPTION OF WORK Gas fireplace/insert k 33.39 Flue vent for water heater or gas HVAC installation at new single family residence fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER I ❑ TENANT Other: 23.32 Environmental exhaust and ventilation: Name:J.T.Roth Construction Inc. Range hood/other kitchen equipment t 33.39 Address:12600 SW 72thl Ave. Clothes dryer exhaust I 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, / toilet compartments,utility rooms) fr, 23.32 Phone:(503)639-2639 Fax:(503)624-0239 Attic/crawlspace fans 23.32 ❑ APPLICANT ® CONTACF PERSON Other: 23.32 Fuel piping: Business name:J.T.Roth Construction Inc. $14.15 for first four;$4.03 for each additional Contact name:David Jensen Furnace,etc. I Address: 12600 SW 72'd Ave. Gas heat pump Wall/suspended/unit heater City/State/ZIP:Tigard,OR 97223 Water heater Phone:(503)806-0602 Fax::(503)624-0239 Fireplace I Range E-mail:davidj @jtrothinc.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:All Time Heating LLC Other: MECHANICAL PERMIT FEES Address:PO Box 1341 Subtotal City/State/ZIP:Lake Oswego,OR 97035 Minimum permit fee($90.00) Plan ceview(25%of permit fee) Phone:(503)208-2276 Fax:(503)208-2276 State surcharge(12%of permit fee) CCB lic.: 184575 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 ht.----rf, days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-County Building Industry Service Board ' Print name:Aaron Svobova ' Date:04/14/2015 1:1Building\Permits\MEC_PermitApp_040113.doc 440-4617T(1 I/02/COM/WEB) a Plumbing Permit Application Building Fixtures I OR (II 11( 1 1 ■I O\I 1 City of Tigard RECEIVED Received Date/By: v�Perm 1 rye it No.: , 5 i 5 C ■ 13125 SW Hall Blvd.,Tigard,OR 97223 ? `APR 2 2 2015 Plan Review Phone: 503.718.2439 Fax: 503.598.1 Date/By: Other Permit No.: l i `1\l� Inspection Line: 503.639.4175 Date Ready/By: Juris: la See Page 2 for Internet: www.tigard-or.gov CITY (IF TIGABD Notified/Method: _ Supplemental Information i TYPE OF winILDING DIVISION FEE* SCHEDULE ®New construction ❑Demolition For special information use checklist Description I Qty. I Ea. I Total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® 1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78 SFR(3)bath # 500.32 ❑Accessory building ❑Multi-family Each additional bath/kitchen 1 25.02 ❑Master builder ❑Other: Fire sprinkler(2942 sq.ft.) Page 2 We,e,q r JOB SiTB INFORMATION AND LOCATION Site utilities: Job site address:,19Nlrr1W 11e Court Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76 City/State/ZIP:Tigard,OR 97224 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: I Project name:Medallion Meadows Manufactured home utilities 50.03 Cross street/directions to job site:Gaarde Roade to 118*Couert Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision:Medallion Meadows I Lot no.:03 Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 Clothes washer 25.02 Plumbing installation of new single family residence Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER I ❑ TENANT Expansion tank 12.51 Name:J.T.Roth Construction Inc. Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address: 12600 SW 72nd.Ave Garbage disposal 25.02 City/State/ZIP:Tigard,OR 97223 Hose bib 25.02 Phone:(503)639-2639 Fax:(503)624-0239 Ice maker 12.51 ❑ APPLICANT ® CONTACT PERSON Interceptor/grease trap 25.02 Business name:J.T.Roth Construction Inc. Medical gas(value:$ ) Page 2 Primer 12.51 Contact name:David Jensen Roof drain(commercial) 12.51 Address:12600 SW 72"Ave. Sink/basin/lavatory 25.02 City/State/ZIP:Tigard,OR 97223 Solar units(potable water) 62.54 Phone:(503)806-0602 Fax::(503)624-0239 Tub/shower/shower pan 12.51 E-mail:davidj @jtrothinc.com Urinal 25.02 Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:Delta Plumbing Inc. Water piping/DWV 56.29 Address: 12205 SE 108"Ave. Other: 25.02 City/State/ZIP:Happy Valley,OR 97086 Subtotal Phone:(503)998-0683 Fax:(503)698-2354 Minimum permit fee: $72.50 CCB Lic.:182846 Plumbing Lic.no.:P13562 Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature � TOTAL PERMIT FEE Print name:Gabriel Boggd� Date:04/14/2015 This Pert application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tn-County Building Industry Service Board. 1:1Building\Pennits\PLMU-PermitApp.doc 10/01/09 440-4616T(10/02/COMIWEB) City of Tigard / I" COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Review — Residential I I( \ I:I) Building Permit #: ft-5r CS—cxx3 s-Co Site Address: 1l4eq9" 4-4-eforN S w 11 Q) d't- C -. Project Name: M e d cat■o r MRcA ck,c)1/4-Ar S Lot #: 2 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: N QA,,,) S F(v Verify site address/suite#exists and active in permit system. $River Terrace Plan District: ❑ Yes ❑ No Site Plan Elements: ,'Three(3)copies of site plan —9-Existing structures on site 1'JSite plan must h€on 8-1/2"x 11"or 11 x 17"paper AFootprint of new structure(including decks)with finished %Drawn to scale(standard architect or engineer scale) floor elevations North arrow ,'Utility locations(required for new,may apply for additions) l Site address,project or subdivision name and lot number I Location of wells/septic systems Applicant information(name and phone number) ,Erosion control(including drainage-way protection,silt fence , Lot dimensions and building setback dimensions design,location of catch basin,etc.) J2Lot area,building coverage area,percentage of coverage and p Street names impervious area(applicable if R-7,R-12,R-25&R-40) ,Street tree size,type and location ¢Property corner elevations(2 foot contour lines if more than 'Existing trees to be retained with drip line,and tree 4 foot differential) protection measures AClean Water Services-Service Provider Letter(lot platted prior to 9/10/1995): Required: ❑ Yes,applicant was notified /Pi No Received: ❑ Yes ❑ No rst Public Facilities Improvement(PFI)Permit: Required: N. Yes,applicant was notified ❑ No Applied For: El Yes El No,stop intake Land Use Case#: EU r3 20 1 3 -- 0000 Co t ((c, ;i-C oL cid4 i 11,y13.-.•}- gr Zoning: V Setbacks: Front 20 Rear (5 Side 5 Street Side 1 C Garage Z v Landscape Requirement: w/A % Zi Lot Coverage Maximum: Zr Building Height: Maximum Height 3 0 Actual Height 2.2 j2r Visual Clearance VI Easements Er Sensitive Lands: ❑ Yes El No Type 1' Urban Forestry Plan Sk-r-eer �T_.e s rte;rem. ._Sh, el O Conditions "Met"prior to issuance of building permit Notes: Approved By Planning: /1'1 o i c a.- I i i 0 ke-CA-A-A- Date: q/ 2-/-/ (.S Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved I:13uilding\Forms\BldgPermitRvw_RES_031015.docx Building Permit Submittal Original Submittal Date: 0-2-l/5- Site Plans: # 3 Building Plans: # 3 Building Permit#: Pinter building permit#above. Workflow Routing: ® anning engineering Chi e t Coordinator ceding Workflow Sign-off: sign-off for Planning(include notes from planning review) Route Application Documents: gineering (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. PU' a lding: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: 4 Date: /!X. / s Engineering Review Cilope at building pad: / > El Conditions "Met"prior to issuance of building permit 'asements (encroachments)per engineering conditions of approval and plat Water Quality/Quantity Facility: �/ Assess Water Quality Fee in-lieu: CI Yes [ o Assess Water Quantity Fee in-lieu: ❑ Yes ,�, No IDA Facility on lot: ❑ Yes o 2 NOT Approved n ineerin g Date: k�— '� Notes: �J �'s 7 1� '47 ' 5—/9--L L Approved by Engineering: iVG J7 ,� Date: —i Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) /YD �n v / ��✓�s o 'v Revision Notice 1: Date Sent to Applicant: 4 2 3 1 S Revision Notice 2: Date Sent to Applicant: _ Revision Notice 3: Date Sent to Applicant: rdiOK to Issue Permit Approved by Permit Coordinator: Ari(----5- ,,,,-(, -- Date: Jv/btrA I:\Bull dingForms\BIdgPermitRvw_RES_031015.docx Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14092 SW 118TH CT, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final PASS MST2015-00056 Jeff Grove Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14092 SW 118TH CT, TIGARD, OR, 97224 Residential - Master Permit 699 Mechanical final FAIL MST2015-00056 David Young Provide duct seal test report for ductwork in crawl space, or blower door test report. AF103.4.8 Seal penetrations in garage. R302.5 Note: no AC installed at time of final inspection, permit and inspection required at time of installation. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14092 SW 118TH CT, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection FAIL MST2015-00056 David Young Provide approved mechanical final inspection. Provide permit, approved back flow test results and approved final inspection for lawn irrigation back flow devise. Seal AC line set penetration in garage wall. R302.5 Fix garage at back corner with standing water in vent well. R401.3 Provide approved plans on site for final inspection. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14092 SW 118TH CT, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection Scheduled MST2015-00056 Jeff Grove Blower door test report received Lighting received Street tree received Moisture content received Insulation underfloor approval recieved Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14092 SW 118TH CT, TIGARD, OR, 97224 Residential - Master Permit 699 Mechanical final PASS MST2015-00056 Jeff Grove Corrections complete Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14092 SW 118TH CT, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection PASS - C of O MST2015-00056 Jeff Grove Blower door test report received Lighting received Street tree received Moisture content received Insulation underfloor approval recieved Violation Summary: Inspector Contractor