Report RECEIVED PAUL J. FORD AND COMPANY • S T R U C T U R A L E N G I N E E R S MAY 182015 250 East Broad Street • Suite 600 • Columbus, Ohio 43215-3708 CITY OFTIGAU Date: March 13, 2015 BUILDING 1itvi jON Saleem Dooh Paul J Ford and Company Crown Castle 250 E. Broad Street Suite 600 5350 North 48th Street Suite 305 Columbus, OH 43215 Chandler, AZ 85226 614.221.6679 Subject: Structural Modification Report Carrier Designation: Sprint PCS Co-Locate Carrier Site Number: P029XC053 Carrier Site Name: N/A Crown Castle Designation: Crown Castle BU Number: 879570 Crown Castle Site Name: WASHINGTON SQUARE MALL Crown Castle JDE Job Number: 306180 Crown Castle Work Order Number: 1017843 Crown Castle Application Number: 255835 Rev. 2 Engineering Firm Designation: Paul J Ford and Company Project Number: 37515-0086.002.7700 Site Data: 9585 SW Washington Sq Rd, TIGARD, Washington County, OR Latitude 45°27'10.7", Longitude -122°46'41.6" 87.25 Foot- Monopole Tower Dear Saleem Dooh, Paul J Ford and Company is pleased to submit this "Structural Modification Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work'and the terms of Crown Castle Purchase Order Number 761311, in accordance with application 255835, revision 2. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC4.5: Modified Structure w/Existing + Proposed Equipment Sufficient Capacity Note:See Table I and Table II for the proposed and existing loading,respectively. This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception#5 of Section 1609.1.1. Exposure Category C with a topographic category 1 and crest height of 0 feet, and Risk Category II were used in this analysis. All modifications and equipment proposed in this report shall be installed in accordance with the atta •:: drawings for the determined available structural capacity to be effective. EU PRO,eS S f�,N3%NE s'i We at Paul J Ford and Company appreciate the opportunity of providing our continuing prof-.4i r.1 services toy Oy you and Crown Castle. If you have any questions or need further assistance on this or any •;.- projdat241 PE f pleas- .ive us a call. ,J', /;�, •-ctfully submitted �1 i50/js ` OREGON ✓/i Y 11 .2°C co �mas J. Dehnke, �`1` Structural Designer lRTJ. SWP* tnxTower Report-version 6.1.4.1 EXPIRES: gbf1J • March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2- Existing Antenna and Cable Information Table 3- Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4- Documents Provided 3.1)Analysis Method 3.2)Assumptions 4) ANALYSIS RESULTS Table 5- Section Capacity (Summary) Table 6—Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 3 1) INTRODUCTION This tower is a 87.25 ft Monopole tower designed by ROHN in July of 2000. The tower was originally designed for a wind speed of 85 mph per TIA/EIA-222-F. 2)ANALYSIS CRITERIA This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception#5 of Section 1609.1.1. Exposure Category C with a topographic category 1 and crest height of 0 feet, and Risk Category II were used in this analysis. Table 1 -Proposed Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Level (ft) Elevation of Manufacturer Antenna Model of Feed Line Note (ft) Antennas Lines Size (in) 3 commscope i DHHTT65B-3XR w/Pipe — -_ _ _--- - ----------------- OPTIC FIBER JUNCTION 84.0 84.0 3 samsung CYLINDER 3 17/16 — 3 samsung POWER JUNCTION CYLINDER 78.0 79.0 I 3 r samsung 2.5G 8T8R RADAR FILTER -- N 76.0 1 3 ! samsung TME-RRH-P4 Table 2- Existing Antenna and C able Inform_ation Center Number Number Feed Mounting Line Antenna Antenna Model of Feed Line Note Level (ft) Elevation Antennas Manufacturer Lines Size (in) (ft) I 84.0 84.0 3 ems wireless RR65-18-04DP w/Pipe I 6 j 1 5/8 ( 2 10 alcatel lucent 9442 RRH 700 W/SOLAR 3 kathrein , 800 10766 w/Mount Pipe 71.0 1 raycap TME-DC6-48-60-18-8F 1 tower mounts Side Arm Mount[SO 101-3] 1 1/4 64.0 QBXLH-6565A-VTM w/ 1 3/8 1 3 andrew 2 5/8 Mount Pipe _ 12 7/8 62.0 2 alcatel lucent 9442 RRH 700 W/SOLAR 12 powerwave ! LGP214nn 1 tower mounts TSide Arm Mount[SO 101-3] Notes: 1) Existing Equipment 2) Equipment To Be Removed Table 3 - Design Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size (in) (ft) tnxTower Report-version 6.1.4.1 1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 4 3)ANALYSIS PROCEDURE Table 4-Documents Provided Document Remarks Reference Source 4-GEOTECHNICAL REPORTS Adapt, OR99-2522, 8/11/1999 1574694 I CCISITES 4-TOWER FOUNDATION Rohn,44583AE, 7/14/2000 1625445 l CCISITES DRAWINGS/DESIGN/SPECS 4-TOWER MANUFACTURER Rohn,44583AE, 7/17/2000 1626447 CCISITES DRAWINGS 4-AUDIT INSPECTION ( FDH, 146E111500, 12/9/2014 I 5486942 1 CCISITES I 3.1) Analysis Method tnxTower(version 6.1.4.1), a commercially available analysis software package,was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas,transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) Monopole will be reinforced in conformance with the attached proposed modification drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Paul J Ford and Company should be notified to determine the effect on the structural integrity of the tower. tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCl BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 5 4)ANALYSIS RESULTS Table 5-Section Capacity(Summary) Section Critical SF*Pallow ti Elevation(ft) Component Type Size P(K) _ Pass I Fail No. Element ( ) Capacity Li I 87.25-75 Pole Pipe 4.5"x 0.337"(4 XS) 1 ( -1.08 166.60 81.0 Pass L2 75-73.25 Pole P30x0.375 2 -1.65 1520.46 1.8 Pass L3 73.25-56.25 Pole P30x0.375 3 -6.72 1520.46 8.4 Pass L4 56.25-40 1 Pole P30x0.375 4 -9.53 1520.46 17.3 Pass I L5 I 40-0 Pole P30x0.375 5 -15.63 1520.46 44.5 I Pass I I I ' ISummaryT I I I Pole(L1) I 81.0 I Pass I I 1 I I I Rating= I 81.0 I Pass Table 6-Tower Component Stresses vs. Capacity Notes Component Elevation (ft) %Capacity Pass I Fail 1 Anchor Rods 0 36.5 I Pass 1 I Base Plate I 0 I 32.3 Pass 1 Base Foundation 0 26.4 Pass Steel 1 2 Base Foundation 0 25.4 Pass Soil Interaction 1 Concealment Flange 75 [ 72.0 Pass I 1 I Flange Connection j 40 I 35.0 Pass Structure Rating (max from all components)= 81.0% Notes: 1) See additional documentation in"Appendix C-Additional Calculations"for calculations supporting the%capacity consumed. 2) According to the procedures prescribed and agreed to by the Crown Castle Engineering Foundation Committee,held in January 2010,the existing caisson foundation was analyzed using the methodology in the software'PLS-Caisson' (Version 8.10,or newer,by Power Line Systems,Inc.). Per the methods in PLS-Caisson,the soil reactions of cohesive soils are calculated using 8CD independent of the depth of the soil layer. The depth of soil to be ignored at the top of the caisson is the greater of the geotechnical report's recommendation,the frost depth of the site or half of the caisson diameter. 4.1) Recommendations •See attached proposed modification drawings l tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CC!BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 6 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCl BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 7 Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: 1) Tower is located in Washington County, Oregon. 2) ASCE 7-10 Wind Data is used (wind speeds converted to nominal values). 3) Basic wind speed of 93 mph. 4) Structure Class II. 5) Exposure Category C. 6) Topographic Category 1. 7) Crest Height 0.00 ft. 8) Nominal ice thickness of 1.2500 in. 9) Ice thickness is considered to increase with height. 10) Ice density of 56 pcf. 11) A wind speed of 30 mph is used in combination with ice. 12) Temperature drop of 50 °F. 13) Deflections calculated using a wind speed of 60 mph. 14) A non-linear(P-delta) analysis was used. 15) Pressures are calculated at each section. 16) Stress ratio used in pole design is 1. 17) Local bending stresses due to climbing loads,feed line supports, and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments-Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules Consider Moments-Diagonals 'J Assume Rigid Index Plate Calculate Redundant Bracing Forces Use Moment Magnification '1 Use Clear Spans For Wind Area Ignore Redundant Members in FEA -NI Use Code Stress Ratios -4 Use Clear Spans For KUr SR Leg Bolts Resist Compression Use Code Safety Factors-Guys Retension Guys To Initial Tension All Leg Panels Have Same Allowable Escalate Ice 4 Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz 4 Use Azimuth Dish Coefficients v Consider Feedline Torque Use Special Wind Profile Project Wind Area of Appurt. Include Angle Block Shear Check Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section SR Members Have Cut Ends ' Include Shear-Torsion Interaction Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC.6D+W Combination Use TIA-222-G Tension Splice Capacity Exemption Pole Section Geometry Section Elevation Section Pole Pole Socket Length Length Size Grade ft ft ft L1 87.25-75.00 12.25 Pipe 4.5"x A500-42 0.337"(4 XS) (42 ksi) L2 75.00-73.25 1.75 P30x0.375 A139-52 (52 ksi) L3 73.25-56.25 17.00 P30x0.375 A139-52 (52 ksi) L4 56.25-40.00 16.25 P30x0.375 A139-52 (52 ksi) L5 40.00-0.00 40.00 P30x0.375 A139-52 (52 ksi) Feed Line/Linear Appurtenances - Entered As Area { tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 8 Description Face Allow Component Placement Total CAAA Weight ., or Shield Type Number Leg ft ft2/R plf TYPE 2(1-7/16) C No Inside Pole 84.00-0.00 3 No Ice 0.00 0.60 1/2"Ice 0.00 0.60 1"Ice 0.00 0.60 2"Ice 0.00 0.60 CR 50 1070(7/8") C No Inside Pole 64.00-0.00 12 No Ice 0.00 0.28 1/2"Ice 0.00 0.28 1"Ice 0.00 0.28 2"Ice 0.00 0.28 FB-L98-002-XXX(3/8) C No Inside Pole 64.00-0.00 1 No Ice 0.00 0.06 1/2"Ice 0.00 0.06 1"Ice 0.00 0.06 2"Ice 0.00 0.06 FB-L98B-035- C No Inside Pole 64.00-0.00 1 No Ice 0.00 0.03 XXX(1/4") 1/2"Ice 0.00 0.03 1"Ice 0.00 0.03 2"Ice 0.00 0.03 WR-VG82ST-BRDA( C No Inside Pole 64.00-0.00 2 No Ice 0.00 0.31 5/8") 1/2"Ice 0.00 0.31 1"Ice 0.00 0.31 2"Ice 0.00 0.31 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side " Leg Lateral t Vert R ft ftz ft2 K ft ° ft Canister Load1 C None 0.0000 87.25 No Ice 25.88 25.88 0.25 1/2" 48.39 48.39 0.54 Ice 70.90 70.90 0.84 1"Ice 115.92 115.92 1.43 2"Ice Canister Load2 C None 0.0000 75.00 No Ice 29.57 29.57 0.29 1/2" 55.30 55.30 0.62 Ice 81.03 81.03 0.96 1"Ice 132.47 132.47 1.63 2"Ice Canister Load3 C None 0.0000 73.25 No Ice 36.85 36.85 0.38 1/2" 74.06 74.06 0.83 Ice 111.28 111.28 1.28 1"Ice 185.71 185.71 2.18 2"Ice Canister Load4 C None 0.0000 56.25 No Ice 33.15 33.15 0.35 1/2" 67.15 67.15 0.76 Ice 101.15 101.15 1.16 1"Ice 169.15 169.15 1.98 2"Ice DHHTT65B-3XR w/Mount A None 0.0000 84.00 No Ice 0.00 0.00 0.07 Pipe 1/2" 0.00 0.00 0.14 Ice 0.00 0.00 0.22 1"Ice 0.00 0.00 0.40 2"Ice DHHTT65B-3XR w/Mount B None 0.0000 84.00 No Ice 0.00 0.00 0.07 Pipe 1/2" 0.00 0.00 0.14 Ice 0.00 0.00 0.22 1"Ice 0.00 0.00 0.40 2"Ice DHHTT65B-3XR w/Mount C None 0.0000 84.00 No Ice 0.00 0.00 0.07 Pipe 1/2" 0.00 0.00 0.14 Ice 0.00 0.00 0.22 - 1"Ice 0.00 0.00 0.40 2"Ice C tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 9 Description Face Offset Offsets: Azimuth Placement C,,AA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft OPTIC FIBER JUNCTION A None 0.0000 84.00 No Ice 0.00 0.00 0.00 CYLINDER 1/2" 0.00 0.00 0.01 Ice 0.00 0.00 0.01 1"Ice 0.00 0.00 0.03 2"Ice OPTIC FIBER JUNCTION B None 0.0000 84.00 No Ice 0.00 0.00 0.00 CYLINDER 1/2" 0.00 0.00 0.01 Ice 0.00 0.00 0.01 1"Ice 0.00 0.00 0.03 2"Ice OPTIC FIBER JUNCTION C None 0.0000 84.00 No Ice 0.00 0.00 0.00 CYLINDER 1/2" 0.00 0.00 0.01 Ice 0.00 0.00 0.01 1"Ice 0.00 0.00 0.03 2"Ice POWER JUNCTION A None 0.0000 84.00 No Ice 0.00 0.00 0.00 CYLINDER 1/2" 0.00 0.00 0.01 Ice 0.00 0.00 0.01 1"Ice 0.00 0.00 0.03 2"Ice POWER JUNCTION B None 0.0000 84.00 No Ice 0.00 0.00 0.00 CYLINDER 1/2" 0.00 0.00 0.01 Ice 0.00 0.00 0.01 • 1"Ice 0.00 0.00 0.03 2"Ice POWER JUNCTION C None 0.0000 84.00 No Ice 0.00 0.00 0.00 CYLINDER 1/2" 0.00 0.00 0.01 Ice 0.00 0.00 0.01 1"Ice 0.00 0.00 0.03 • 2"Ice 2.5G 8T8R RADAR A From Leg 0.00 0.0000 78.00 No Ice 0.00 0.00 0.02 FILTER 0.00 1/2" 0.00 0.00 0.03 1.00 Ice 0.00 0.00 0.04 1"Ice 0.00 0.00 0.06 2"Ice 2.5G 8T8R RADAR B From Leg 0.00 0.0000 78.00 No Ice 0.00 0.00 0.02 FILTER 0.00 1/2" 0.00 0.00 0.03 1.00 Ice 0.00 0.00 0.04 1"Ice 0.00 0.00 0.06 2"Ice 2.5G 8T8R RADAR C From Leg 0.00 0.0000 78.00 No Ice 0.00 0.00 0.02 FILTER 0.00 1/2" 0.00 0.00 0.03 1.00 Ice 0.00 0.00 0.04 1"Ice 0.00 0.00 0.06 2"Ice TME-RRH-P4 A From Leg 0.00 0.0000 78.00 No Ice 0.00 0.00 0.06 0.00 1/2" 0.00 0.00 0.08 -2.00 Ice 0.00 0.00 0.11 1"Ice 0.00 0.00 0.17 2"Ice TME-RRH-P4 B From Leg 0.00 0.0000 78.00 No Ice 0.00 0.00 0.06 0.00 1/2" 0.00 0.00 0.08 -2.00 Ice 0.00 0.00 0.11 1"Ice 0.00 0.00 0.17 2"Ice TME-RRH-P4 C From Leg 0.00 0.0000 78.00 No Ice 0.00 0.00 0.06 0.00 1/2" 0.00 0.00 0.08 -2.00 Ice 0.00 0.00 0.11 1"Ice 0.00 0.00 0.17 2"Ice 800 10766 w/Mount Pipe A From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.09 0.00 1/2" 0.00 0.00 0.17 tnxTower Report-version 6.1.4.1 r March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCl BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 10 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ftz fiz K ft ° ft 7.00 Ice 0.00 0.00 0.27 1"Ice 0.00 0.00 0.49 2"Ice 800 10766 w/Mount Pipe B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.09 0.00 1/2" 0.00 0.00 0.17 7.00 Ice 0.00 0.00 0.27 1"Ice 0.00 0.00 0.49 2"Ice 800 10766 w/Mount Pipe C From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.09 0.00 1/2" 0.00 0.00 0.17 7.00 Ice 0.00 0.00 0.27 1"Ice 0.00 0.00 0.49 2"Ice (4)9442 RRH 700 A From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.05 W/SOLAR 0.00 1/2" 0.00 0.00 0.07 7.00 Ice 0.00 0.00 0.10 1"Ice 0.00 0.00 0.16 2"Ice (2)9442 RRH 700 B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.05 W/SOLAR 0.00 1/2" 0.00 0.00 0.07 7.00 Ice 0.00 0.00 0.10 1"Ice 0.00 0.00 0.16 2"Ice (4)9442 RRH 700 B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.05 W/SOLAR 0.00 1/2" 0.00 0.00 0.07 7.00 Ice 0.00 0.00 0.10 1"Ice 0.00 0.00 0.16 2"Ice TME-DC6-48-60-18-8F A From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.02 0.00 1/2" 0.00 0.00 0.04 7.00 Ice 0.00 0.00 0.06 1"Ice 0.00 0.00 0.11 2"Ice Side Arm Mount[SO 101- C From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.25 3] 0.00 1/2" 0.00 0.00 0.33 7.00 Ice 0.00 0.00 0.41 1"Ice 0.00 0.00 0.58 2"Ice Irk QBXLH-6565A-VTM w/ A From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.09 Mount Pipe 0.00 1/2" 0.00 0.00 0.18 -2.00 Ice 0.00 0.00 0.26 1"Ice 0.00 0.00 0.47 2"Ice QBXLH-6565A-VTM w/ B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.09 Mount Pipe 0.00 1/2" 0.00 0.00 0.18 -2.00 Ice 0.00 0.00 0.26 1"Ice 0.00 0.00 0.47 2"Ice QBXLH-6565A-VTM w/ C From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.09 Mount Pipe 0.00 1/2" 0.00 0.00 0.18 -2.00 Ice 0.00 0.00 0.26 1"Ice 0.00 0.00 0.47 2"Ice (4)LGP214nn A From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.01 0.00 1/2" 0.00 0.00 0.02 -2.00 Ice 0.00 0.00 0.03 1"Ice 0.00 0.00 0.05 2"Ice ' (4)LGP214nn B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.01 0.00 1/2" 0.00 0.00 0.02 -2.00 Ice 0.00 0.00 0.03 1"Ice 0.00 0.00 0.05 2"Ice C. (4)LGP214nn B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.01 tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CC!BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 11 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight . or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft 0.00 1/2" 0.00 0.00 0.02 -2.00 Ice 0.00 0.00 0.03 1"Ice 0.00 0.00 0.05 2"Ice (2)9442 RRH 700 B From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.05 W/SOLAR 0.00 1/2" 0.00 0.00 0.07 -2.00 Ice 0.00 0.00 0.10 1"Ice 0.00 0.00 0.16 2"Ice Side Arm Mount[SO 101- C From Leg 0.00 0.0000 64.00 No Ice 0.00 0.00 0.25 3] 0.00 1/2" 0.00 0.00 0.33 -2.00 Ice 0.00 0.00 0.41 1"Ice 0.00 0.00 0.58 2"Ice Tower Pressures - No Ice GH=1.100 Section z KZ q= AG F AF AR A,.9 Leg CAAA CAAA Elevation a % In Out . c Face Face ft ft psf ft2 e ft2 ft2 ft2 ft2 ft2 L1 87.25- 81.13 1.211 25 4.594 A 0.000 0.000 0.000 0.00 0.000 0.000 75.00 B 0.000 0.000 0.00 0.000 0.000 - C 0.000 0.000 0.00 0.000 0.000 L2 75.00- 74.13 1.188 25 4.375 A 0.000 0.000 0.000 0.00 0.000 0.000 73.25 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L3 73.25- 64.75 1.155 24 42.500 A 0.000 0.000 0.000 0.00 0.000 0.000 56.25 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L4 56.25- 48.13 1.085 23 40.625 A 0.000 40.625 40.625 100.00 0.000 0.000 40.00 B 0.000 40.625 100.00 0.000 0.000 C 0.000 40.625 100.00 0.000 0.000 L5 40.00-0.00 20.72 0.909 19 100.00 A 0.000 100.000 100.000 100.00 0.000 0.000 0 B 0.000 100.000 100.00 0.000 0.000 C _ 0.000 100.000 _ 100.00 0.000 0.000 Tower Pressure - With Ice GH=1.100 Section z K2 q., tz AG F AF AR Amy Leg CAAA CAAA Elevation a % In Out c Face Face ft ft _ psf in ft e ft2 ft2 ft2 ft2 ft2 L1 87.25-75.00 81.13 1.211 3 2.7353 10.178 A 0.000 0.000 0.000 0.00 0.000 0.000 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L2 75.00-73.25 74.13 1.188 3 2.7107 5.166 A 0.000 0.000 0.000 0.00 0.000 0.000 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L3 73.25-56.25 64.75 1.155 3 2.6743 50.077 A 0.000 0.000 0.000 0.00 0.000 0.000 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L4 56.25-40.00 48.13 1.085 2 2.5961 47.656 A 0.000 47.656 47.656 100.00 0.000 0.000 B 0.000 47.656 100.00 0.000 0.000 . C 0.000 47.656 100.00 0.000 0.000 L5 40.00-0.00 20.72 0.909 2 2.3863 115.909 A 0.000 115.909 115.909 100.00 0.000 0.000 L. B 0.000 115.909 100.00 0.000 0.000 tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCl BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 12 Section z Kz q, tz AG F AF AR A,a9 Leg CAAA CAAA Elevation a % In Out c Face Face ft ft psf in ft2 e ft2 ft2 ft2 _ ft2 ft2 C 0.000 115.909 100.00 0.000 0.000 Tower Pressure - Service GH= 1.100 Section z Kz q, AG F , AF AR A,e9 Leg CAAA CAAA Elevation a % In Out c Face Face ft ft psf ft2 e ft2 ft2 ft2 ft2 L1 87.25- 81.13 1.211 9 4.594 A 0.000 0.000 0.000 0.00 0.000 0.000 75.00 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L2 75.00- 74.13 1.188 9 4.375 A 0.000 0.000 0.000 0.00 0.000 0.000 73.25 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L3 73.25- 64.75 1.155 9 42.500 A 0.000 0.000 0.000 0.00 0.000 0.000 56.25 B 0.000 0.000 0.00 0.000 0.000 C 0.000 0.000 0.00 0.000 0.000 L4 56.25- 48.13 1.085 8 40.625 A 0.000 40.625 40.625 100,00 0.000 0.000 40.00 B 0.000 40.625 100.00 0.000 0.000 C 0.000 40.625 100.00 0.000 0.000 L5 40.00-0.00 20.72 0.909 7 100.00 A 0.000 100.000 100.000 100.00 0.000 0.000 0 B 0.000 100.000 100.00 0.000 0.000 C 0.000 100.000 100.00 0.000 0.000 Load Combinations Comb. Description No. _ 1 Dead Only . 2 1.2 Dead+1.6 Wind 0 deg-No Ice 3 0.9 Dead+1.6 Wind 0 deg-No Ice 4 1.2 Dead+1.6 Wind 30 deg-No Ice 5 0.9 Dead+1.6 Wind 30 deg-No Ice 6 1.2 Dead+1.6 Wind 60 deg-No Ice 7 0.9 Dead+1.6 Wind 60 deg-No Ice 8 1.2 Dead+1.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+1.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+1.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+1.6 Wind 240 deg-No Ice 20 1.2 Dead+1.6 Wind 270 deg-No Ice 21 0.9 Dead+1.6 Wind 270 deg-No Ice 22 1.2 Dead+1.6 Wind 300 deg-No Ice 23 0.9 Dead+1.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+1.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp tnxTower Report-version 6.1.4.1 March 13,2015 87.25 Ft Monopole Tower Structural Analysis CC!BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 13 Comb. Description . No. 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Maximum Member Forces I Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft L1 87.25-75 Pole Max Tension 45 0.00 0.00 0.00 Max.Compression 26 -5.57 -0.00 -0.00 Max.Mx 20 -1.08 14.82 -0.00 Max.My 14 -1.08 0.00 -14.82 Max.Vy 20 -1.22 12.35 -0.00 Max.Vx 14 1.22 0.00 -12.35 Max.Torque 20 -0.00 L2 75-73.25 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -8.18 -0.00 -0.00 Max.Mx 20 -1.65 19.22 -0.00 Max.My 14 -1.65 0.00 -19.22 Max.Vy 20 -2.52 19.22 -0.00 Max.Vx 14 2.52 0.00 -19.22 Max.Torque 20 %M alt L3 73.25- Pole Max Tension 1 0.00 0.00 0.00 56.25 Max.Compression 26 -24.79 -1.06 -0.74 Max.Mx 20 -6.72 90.48 -0.35 Max.My 14 -6.72 0.03 -90.80 Max.Vy 20 -4.24 90.48 -0.35 Max.Vx 14 4.24 0.03 -90.80 Max.Torque 34 -0.00 L4 56.25-40 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -31.47 -1.06 -0.74 Max.Mx 20 -9.53 189.99 -0.35 Max.My 14 -9.53 0.03 -190.31 Max.Vy 20 -6.62 189.99 -0.35 Max.Vx 14 6.62 0.03 -190.31 Max.Torque 34 -0.00 L5 40-0 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -41.23 -1.05 -0.73 Max.Mx 20 -15.63 495.02 -0.36 Max.My 14 -15.63 0.03 -495.35 Max.Vy 20 -8.50 495.02 -0.36 Max.Vx 14 8.50 0.03 -495.35 . Max.Torque 34 -0.00 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 87.25-75 4.902 45 0.9110 0.0000 r L2 75-73.25 3.096 45 0.2885 0.0000 tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 14 Section Elevation Horz. Gov. Tilt Twist _ No. Deflection Load ft in Comb. • L3 73.25-56.25 2.991 45 0.2880 0.0000 L4 56.25-40 1.988 45 0.2718 0.0000 L5 40-0 1.121 45 0.2326 0.0000 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 87.25 Canister Load1 45 4.902 0.9110 0.0000 1573 84.00 DHHTT65B-3XR w/Mount Pipe 45 4.307 0.6788 0.0000 1573 78.00 2.5G 8T8R RADAR FILTER 45 3.387 0.3527 0.0000 893 75.00 Canister Load2 45 3.096 0.2885 0.0000 1122 73.25 Canister Load3 45 2.991 0.2880 0.0000 2135 64.00 800 10766 w/Mount Pipe 45 2.452 0.2890 0.0000 74089 56.25 Canister Load4 45 1.988 0.2718 0.0000 30246 Maximum Tower Deflections - Design Wind I Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. • L1 87.25-75 21.080 14 3.9216 0.0001 L2 75-73.25 13.312 14 1.2398 0.0000 L3 73.25-56.25 12.858 14 1.2376 0.0000 L4 56.25-40 8.548 14 1.1684 0.0000 L5 40-0 4.824 14 1.0003 0.0000 Critical Deflections and Radius of Curvature - Design Wind , Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 87.25 Canister Load1 14 21.080 3.9216 0.0001 367 84.00 DHHTT65B-3XR w/Mount Pipe 14 18.522 2.9214 0.0001 367 78.00 2.5G 8T8R RADAR FILTER 14 14.561 1.5166 0.0000 208 75.00 Canister Load2 14 13.312 1.2398 0.0000 261 73.25 Canister Load3 14 12.858 1.2376 0.0000 496 64.00 800 10766 w/Mount Pipe 14 10.543 1.2420 0.0000 17384 56.25 Canister Load4 14 8.548 1.1684 0.0000 7081 Compression Checks Pole Design Data Section Elevation Size L L„ Kl/r A P„ +P" Ratio No. P" ft ft ft in2 K K +P" . L1 87.25-75(1) Pipe 4.5"x 0.337"(4 XS) 12.25 0.00 0.0 4.4074 -1.08 166.60 0.006 L2 75-73.25(2) P30x0.375 1.75 0.00 0.0 34.901 -1.65 1520.46 0.001 1 L3 73.25-56.25 P30x0.375 17.00 0.00 0.0 34.901 -6.72 1520.46 0.004 (3) 1 L4 56.25-40(4) P30x0.375 16.25 0.00 0.0 34.901 -9.53 1520.46 0.006 1 L5 40-0(5) P30x0.375 40.00 0.00 0.0 34.901 -15.63 1520.46 0.010 1 C- tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835,Revision 2 Page 15 Pole Bending Design Data Section Elevation Size M„, 0M„, Ratio M„ 0M ro Ratio No. Mme, M,,y ft kip-ft kip-ft jg; kip-ft kip-ft 4,M„y L1 87.25-75(1) Pipe 4.5"x 0.337"(4 XS) 14.82 18.44 0.804 0.00 18.44 0.000 L2 75-73.25(2) P30x0.375 19.22 1139.33 0.017 0.00 1139.33 0.000 L3 73.25-56.25 P30x0.375 90.80 1139.33 0.080 0.00 1139.33 0.000 (3) L4 56.25-40(4) P30x0.375 190.31 1139.33 0.167 0.00 1139.33 0.000 L5 40-0(5) P30x0.375 495.36 1139.33 0.435 0.00 1139.33 0.000 Pole Shear Design Data Section Elevation Size Actual 4iV„ Ratio Actual ip T Ratio No. V„ V„ T„ T„ ft K K 011„ kip-ft kip-ft y4T„ L1 87.25-75(1) Pipe 4.5"x 0.337"(4 XS) 1.21 83.30 0.014 0.00 26.91 0.000 L2 75-73.25(2) P30x0.375 2.52 760.23 0.003 0.00 1853.66 0.000 L3 73.25-56.25 P30x0.375 4.24 760.23 0.006 0.00 1853.66 0.000 (3) L4 56.25-40(4) P30x0.375 6.62 760.23 0.009 0.00 1853.66 0.000 L5 40-0(5) P30x0.375 8.50 760.23 0.011 0.00 1853.66 0.000 • Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. Pu M„, M„,. V„ T„ Stress Stress - ft $P„ dM„, 4M„y OV„ mT Ratio Ratio s L1 87.25-75(1) 0.006 0.804 0.000 0.014 0.000 0.810 1.000 4.8.2 y V L2 75-73.25(2) 0.001 0.017 0.000 0.003 0.000 0.018 1.000 4.8.2 V V L3 73.25-56.25 0.004 0.080 0.000 0.006 0.000 0.084 1.000 4.8.2 V (3) ✓ L4 56.25-40(4) 0.006 0.167 0.000 0.009 0.000 0.173 1.000 4.8.2 V L5 40-0(5) 0.010 0.435 0.000 0.011 0.000 0.445 1.000 4.8.2✓ V Section Capacity Table Section Elevation Component Size Critical P eP,e„,. % Pass No. ft Type Element K K Capacity Fail L1 87.25-75 Pole Pipe 4.5"x 0.337"(4 XS) 1 -1.08 166.60 81.0 Pass L2 75-73.25 Pole P30x0.375 2 -1.65 1520.46 1.8 Pass L3 73.25-56.25 Pole P30x0.375 3 -6.72 1520.46 8.4 Pass L4 56.25-40 Pole P30x0.375 4 -9.53 1520.46 17.3 Pass L5 40-0 Pole P30x0.375 5 -15.63 1520.46 44.5 Pass _ Summary Pole(L1) 81.0 Pass RATING= 81.0 Pass e tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CCI BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 16 APPENDIX B BASE LEVEL DRAWING (PROPOSED) (3) 1-7/16" TO 84 FT LEVEL (INSTALLED-TO BE REMOVED) (6) 1-5/8" TO 84 FT LEVEL .OR 0q 03 Or. 02 (INSTALLED) S (1) 1/4" TO 64 FT LEVEL • (1) 3/8" TO 64 FT LEVEL (2) 5/8" TO 64 FT LEVEL 12) 7/8" TO LEVEL 7/8" TO 64 FT LEVEL • tnxTower Report-version 6.1.4.1 March 13, 2015 87.25 Ft Monopole Tower Structural Analysis CC/BU No 879570 Project Number 37515-0086.002.7700,Application 255835, Revision 2 Page 17 APPENDIX C ADDITIONAL CALCULATIONS Program Version 6.1.4.1 -12/17/2013 FiIe:T:/375_Crown_Castle/201 5/37 51 5-00 86_879570_WASHINGTON SQUARE MALL/37515- 0086.002.7700 SDD 1 01 7 843/37 5 1 5-0086.002.7700 With Concealments.eri tnxTower Report-version 6.1.4.1 87.3 ft N X DESIGNED APPURTENANCE LOADING q 11 I N TYPE ELEVATION TYPE ELEVATION ' x ° Canister Load1 87.25 800 10766 w/Mourn Pipe 64 e DHHTT65B-3xR w/Mount Pipe 84 80010766 wl Mount Pipe 64 .Ir DI -3XR w/Mount Pipe 64 800 10766 wl Mown Rpe 64 a DHHTT65B-3xR wl Mount Pipe 84 (4)9442 RRH 700 W ISOLAR 64 ' OPTIC FIBER JUNCTION CYLINDER 84 (2)9442 RRH 700 W/SOLAR 64 75.0 8 OPTIC FIBER JUNCTION CYLINDER 84 w + n (4)9442 RRH 700 W ISOLAR 64° 73.3 R OPTIC FIBER JUNCTION CYLINDER 84 TIME-DCS-48-60.18.8F 64 POWER JUNCTION CYLINDER 54 -Side Arm Mount[SO 101-3] 64 POWER JUNCTION CYLINDER 84 OBXLH-6565A-VTM w/Mount Pipe 64 POWER JUNCTION CYLINDER 84 OBXLH-6565A-1/11A w/Mount Pipe 64 2.5G 8T8R RADAR FILTER 78 OBXLH-6565A-VTM w/Mount Pip. 64 2.5G 8T8R RADAR FILTER 78 (4)LGP214nn 64 2.5G 8T8R RADAR FILTER 78 (4)LGP214nn 64 rm • TME-RRH-P4 78 (4)LGP214nn 64 "' i g n TME-RRH-P4 73 (2)9442 RRH 700 WBOLAR 64 TI14E-RRH-P4 78 Side Mn Moue[SO 101.31 64 Canister Laed2 75 Canister Load4 56.25 Canister Losd3 73.25 MATERIAL STRENGTH GRADE Fy I Fu GRADE Fy Fu s mn A500.42 42 kW 158 kat A139.52 52 ka1 66 kal TOWER DESIGN NOTES 1. Tower is located in Washington County,Oregon. 2. Tower designed for Exposure C to the TIA-222-G Standard. is 3. Tower designed for a 93 mph basic wind in accordance with the TIA-222-G Standard. Pv w 4. Tower is also designed for a 30 mph basic wind with 1.25 in ice.Ice is considered to . m increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. O 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING:81% 40.0 ft $ At ALL REACTIONS O 2 ARE FACTORED AXIAL 41K SHEAR MOMENT 3 K I J 1 185 kip-ft TORQUE 0 kip-ft 30 mph WIND-1.2500 in ICE AXIAL 16K SHEAR\ MOMENT 8 K )1 J 1 495 kip-ft 0.011 ;; TORQUE 0 kip-ft REACTIONS-93 mph WIND E Y S 0 3 it Paul J.Ford and Company d° 87'Monopole 250 East Broad St, Suite 600 Proiect PJF A37515-0086.001.7805/BU 879570 Columbus, OH 43215 c"a"L'Crown Castle DrawnbTDehnke 'pp'd: Phone:614.221.6679 Coda: TIA-222-G Date 03116/15 S`al8: NTS FAX: Path:__._..— ____.__..,..__�e. No.E_1 0 PAUL J. FORD AND COMPANY Job Number: 37515-0086.002.7700 Page: 1 of 1 S T R U C T U R A L E N G I N E E R S Engineer: TJD Date: 3/16/2015 _ nil 230 East Broad5treet • State 600 • Columbus, Ohio 43215-3708 Site Name: WASHINGTON SQUARE MALL Version: v0.5. Site Number: 879570 Effective: 1/20/2015 (c)Copyright 2014 by Paul J.Ford and Company,all rights reserved. CODE: TIA-222-G ASIF: 1.00 75 FT CONCEALMENT FLANGE CONNECTION CALCULATIONS BOLT INFORMATION FLANGE REACTIONS Qty: 6.00 ea. Moment(Mu): 14.82 kip*ft Diameter: 0.625 in. Axial (Pu): 1.08 kips Specification: A325 Shear(Vu): 1.21 kips Bolt Fy 90 ksi Elevation: 75.00 ft Bolt Fu 120 ksi Max Ratio: _ 1.05 Bolt Circle: 8.0 in. CONCEALMENT FLANGE INFORMATION /rl1T Spoke Thickness (t): 2.75 in. Spoke Width (w): 4.00 in. Steel Grade (Fy): 36 ksi CONCEALMENT SPINE INFORMATION Diameter: 4.50 in. dtryta;,, Thickness: 0.337 in. ii,� �''► Steel Grade (Fy): 42 ksi ° � °/ STIFFENER INFORMATION `■ Configuration: No Stiffeners \IN.._ 1 —= �/� Weld Size: in. Width: in. Height: in. FLANGE CONNECTION RESULTS Thickness: in. Notch: in. Flange Bolts: 71.6% Passing Steel Grade: ksi Weld Strength: ksi BASE POLE INFORMATION Pole Diameter: 30.00 in. Pole Thickness: 0.375 in. BASE POLE FLANGE INFORMATION Concealment Flange Plate: 18.2% Passing Connected to: Monopole Weld Type: Fillet Base Pole Flange Plate: 65.0% Passing Weld Size: 0.375 in. Base Pole Flange Weld: 11.7% Passing Weld Strength: 70 ksi Spoke Thickness (t): 2.75 in. in. (Override) Spoke Width (w): 4 in. in. (Override) Steel Grade (Fy): 36 ksi ksi(Override) - Stiffened or Unstiffened, Exterior Flange Plate - Any Bolt Material TIA Rev G Reactions Bolt Threads: Site Data Mu 14.82 ft-kips X-Excluded BU#: 879570 Axial, Pu: 1.08 kips cpVn=cp(0.55*Ab*Fu) Site Name: Washington Square Mall Shear,Vu: 1.21 kips cp=0.75, cp*Vn(kips): App#: Elevation: 75 feet 15.19 Pole Manufacturer:1 Other If No stiffeners,Criteria: TIA G <-Only Applcable to Unstiffened Cases _ Flange Bolt Results Rigid Bolt Data Bolt Tension Capacity,W*Tn,B1: 20.34 kips c'-In Qty: 6 Adjusted cp*Tn(due to Vu=Vu/Qty), B: 20.34 kips cpTn[(1-(Vu/wVn)^21^0.5 Diameter(in.): 0.625 _ Bolt Fu: 120 Max Bolt directly applied Tu: 14.64 Kips Bolt Material: A325 _ Bolt Fy: 92 Min. PL"tc"for B cap.w/o Pry: 0.975 in N/A: 75 <--Disregard Min PL"treq"for actual T wl Pry: 0.633 in N/A: __ 55 <--Disregard Min PL"t1"for actual T w/o Pry: 0.827 in Circle (in.): 8 T allowable w/o Prying: 20.34 kips a'<0 case Prying Force, q: 0.00 kips Plate Data Total Bolt Tension=Tu+q: 14.64 kips Diam: 11 in Non-Prying Bolt Stress Ratio,Tu/B: 72.0% Pass Thick,t: 2 in Grade(Fy): 36 ksi Exterior Flange Plate Results Flexural Check Rigid Strength, Fu: 58 ksi Compression Side Plate Stress: 4.8 ksi TIA G Single-Rod B-eff: 2.36 in Allowable Plate Stress: 32.4 ksi w*Fy Compression Plate Stress Ratio: 14.7% Pass Comp.Y.L.Length: Stiffener Data (Welding at Both Sides) No Prying 6.61 Config: 0 * Tension Side Stress Ratio, (treq/t)^2: 10.0% Pass Weld Type: Groove Depth: in** n/a Groove Angle: degrees Stiffener Results Fillet H.Weld: <--Disregard Horizontal Weld : n/a Fillet V.Weld: in Vertical Weld: n/a Width: in Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a Height: in Plate Tension+Shear,ft/Ft+(fv/Fv)^2: n/a Thick: in Plate Comp. (AISC Bracket): n/a Notch: in Pole Results Grade: ksi Pole Punching Shear Check: n/a Weld str.: ksi Pole Data r \ v Diam: 4.5 in *., _ Thick: 0.337 in i i '' Grade: 42 ksi )'p" i o)! #of Sides: 0 "0"IF Round Fu, 60 ksi 0 Reinf.Fillet Weld 0 "0"if None a. o '0=none,1=every bolt,2=every 2 bolts,3=2 per bolt **Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate 1.5- Ext Flange G 1.3, Effective March 19, 2012 Analysis Date:3/16/2015 - Stiffened or Unstiffened, Interior Flange Plate - Any Bolt Material TIA Rev G Site Data Reactions Bolt Threads: BU#: 879570 Moment: 190.31 ft-kips X-Excluded Site Name: Axial: 9.53 kips rpVn=cp(0.55*Ab*Fu) App#: Shear: 6.62 kips p=0.75,rp'Vn(kips): Exterior Flange Run,T+q; kips 38.88 Manufacturer:1 Other Elevation: 40 feet Bolt Data Qty: 23 Diam: 1 Bolt Fu: 120 Bolt Material: A325 Bolt Fy: 92 _Interior Flange Bolt Results N/A: 100 <--Disregard Maximum Bolt Tension,Tu: 14.9 Kips,Ext.Tu=Interior Tu N/A: 75 <--Disregard Adjusted rp*Tn(due to Vu=Vu/Qty), I 54.5 Kips Circle: 26 in Bolt Stress Ratio: 27.2% Pass Plate Data Plate Outer Diam: 29.25 in Interior Flange Plate Results Flexural Check Plate Inner Diam: 22 in(Hole @ Ctr) Controlling Bolt Axial Force: 15.7 Kips,Ext.Cu=Interior Cu Thick: 1.5 in Plate Stress: 11.3 ksi Grade: 36 ksi Allowable Plate Stress, rp`Fy: 32.4 ksi Effective Width: 4.00 in Plate Stress Ratio: 35.0% Pass Stiffener Data (Welding at Both Sides) n/a Config: 0 Stiffener Results Weld Type: Horizontal Weld : n/a Groove Depth: in** Vertical Weld: n/a Groove Angle: degrees Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a Fillet H.Weld: <--Disregard Plate Tension+Shear,ft/Ft+(fv/Fv)^2: n/a Fillet V.Weld: in Plate Comp. (AISC Bracket): n/a Width: in Height: in Pole Results Thick: _ in Pole Punching Shear Check: n/a Notch: in Grade: ksi Weld str.: ksi x Pole Data ,r' .-^ -.;p Pole OuterDiam: 30 in 70 o\,. Thick: 0.375 in r Pole Inner Diam: 29.25 in ' . o Grade: 52 ksi } j 1 #of Sides: 0 °0•IF Round r\0``t ''01 Fu 60 ksi ` o r1'o{., -'-•;,. �, 0=none,1 =every bolt,2=every 2 bolts,3=2 per bolt "Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes r CClplate 1.5-Int Flange G 1.2, Effective March 19,2012 Analysis Date: 3/16/2015 - Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material TIA Rev G Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding (1)*(Rod Diameter) Site Data Reactions BU#: 879570 Mu: 495 ft-kips Site Name: Washington Square Mall Axial,Pu: 16 kips App#: Shear,Vu: 8 kips Pole Manufacturer.1 Other Eta Factor, rj 0.5 TIA G(Fig.4-4) Anchor Rod Data If No stiffeners,Criteria: AISC LRFD <-Only Applcable to Unstiffened Cases Qty: 14 Diam: 1.5 in Rod Material: Other Anchor Rod Results Rigid Strength (Fu): 125 ksi Max Rod (Cu+Vu/rj): 51.5 Kips AISC LRFD Yield(Fy): 150 ksi Allowable Axial, CO*Fu*Anet: 141.0 Kips ip*Tn Bolt Circle: 34.5 in Anchor Rod Stress Ratio: 36.5% Pass Plate Data Diam: 40.5 in Base Plate Results Flexural Check Rigid Thick: 2 in Base Plate Stress: 10.5 ksi AISC LRFD Grade: 36 ksi Allowable Plate Stress: 32.4 ksi ip*Fy _ Single-Rod B-eff: 6.73 in Base Plate Stress Ratio: 32.3% Pass Y.L.Length: 17.04 _ Stiffener Data (Welding at both sides) n/a Config: 0 * Stiffener Results Weld Type: Horizontal Weld : n/a Groove Depth: in** Vertical Weld: n/a Groove Angle: degrees Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a Fillet H.Weld: <--Disregard Plate Tension+Shear,fUFt+(fv/Fv)^2 n/a Fillet V.Weld: in Plate Comp. (AISC Bracket): n/a Width: in Height: in Pole Results Thick: in Pole Punching Shear Check: n/a Notch: in Grade: ksi Weld str.: ksi Pole Data Diam: 30 in r'is a -.-•, Thick: 0.375 in / .....----•x., ,, Grade: 52 ksi /0 './. y #of Sides: 0 "0"IF Round (0.,/ ' i '1 Fu 60 ksi [j 0;` :) i Reinf.Fillet Weld 0 "0"if None 1 a woo *0=none,1=every bolt,2=every 2 bolts,3=2 per bolt **Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate 1.5- Circular Base G 1.3, Effective March 19, 2012 Analysis Date: 3/16/2015 CCI Flagpole Tool ! C O S EN AT�� . Site Data BU#: 879570-Top Canisters Site Name: App#: Code Code: TIA-222-G Ice Thickness: 1.25 in Windspeed(V): 120 mph — Pill SPINE Ice Wind Speed(V): 30 mph FLANGE BOLT HOLES , Exposure Category: C Q /i , ) Topographic Feature: N/A Structure Class: II '�,'.„/�` )ENER Ili Tower Information I I -`/ FLANGE ATE ' Total Tower Height: 87.25 ft 1. Base Tower Height: 56.25 ft FLANGE PLATE Total Canister Length: 31 ft (TYPE 3:SOLIDITY RATIO 0.5) Number of Canister Assembly, Sections: 3 Mating Mating 1 Canister Canister Flange Flange Plate Canister Canister Section Number of Sides Plate Solidity Assembly Assembly Plate Plate Weight Weight Number': Canister Section Type: Ratio Length(ft): Diameter(in): Thickness Diameter (Kip): (Kip) (inl": (inl: 1 12.25 78 18 3 0.00 78 0.5 0.000 0.500 2 1.75 78 18 3 0.00 78 0.5 0.000 0.071 3 17 78 Round 3 0.00 78 0.5 _ 0.000 0.694 Sections are numbered from the top of the tower down ..Mating Flange Plate Thickness at the bottom of canister section Flag on Tower: No Truck Ball on Tower: No Geometry:Base Tower +Spine A37515-0086.001.7805.eri (last saved 03/10 1:26 pm) Top Bottom Wall Pole Height Above Section Lap Splice Diameter Diameter Thickness Bend Pole Base(ft) Length(ft) Length(ft) Number of Sides (in) (in) (in) Radius(in) Material Delete 87.25 12.25 0 4.5 4.5 0.337 n/a A53-B-42 [x] 75 1.75 0 30 30 0.375 n/a A139-52 [x] 73.25 17 0 30 30 0.375 n/a A139-52 [x] 56.25 16.25 0 30 30 0.375 n/a A139-52 [x] . 40 40 0 30 30 0.375 n/a A139-52 [x] . Discrete Loads:CFAF for Canister Assembly Page 1 of 2 CCIFlagpole Tool v1.0 Canister Apply CFAF at Canister Assembly Canister Loading Elevation(z) CFAF CFAF CFAF CFAF CFAF Assembly Weight (ft) No Ice(ft2) 1/2"Ice(ft) 1"Ice(ft) 2"Ice(ft2) 4"Ice(ft2) Weight No 1/2"Ice Ice(Kip) (Kip) Canister Load 1 87.25 25.878 48.388 49.000 _ 50.225 52.675 0.250 0.544 Canister Load 2 75 29.575 55.300 56.000 57.400 60.200 0.286 0.622 Canister Load 3 73.25 36.847 74.063 75.000 76.875 80.625 0.383 0.832 Canister Load 4 56.25 33.150 67.150 68.000 69.700 73.100 0.347 0.755 Deflection Check Required: I Yes I Import Deflection Results 3%Spine Deflection Check Allowable(3%)Horizontal Spine Actual Sufficient/Insufficient Deflection(inches) Deflection , ***finches) 11.160 2.913 Sufficient •••Relative deflection under service level wind speed Page 2 of 2 CCIFlagpole Tool v1.0 PAUL I. FORD AND COMPANY Job Number: 37515-0086.002.7700 Page: 1 S T R U C T U R A L E N G I N E E R S Site Number: 879570 By: TJD zi(x Last Benad Sore • SOW•ou • Columbus,Ohio 432i5ttos Site Name: WASHINGTON SQUARE MALL Date: 3/16/2015 DRILLED PIER SOIL AND STEEL ANALYSIS-TIA-222-G Factored Base Reactions from RISA Safety Factors/Load Factors/ Factors_ Comp.(+) Tension(-) Tower Type= Monopole DP • Moment,Mu= 495.0- - - -ft ACI Code= ACI 318-08 Shear,Vu= 8.0": ®' �' ' ips Seismic Design Category= D Axial Load,Pu1= 16.0 OM t r 4 vae!!. . ips(from 1.2D+1.6W)* Reference Standard= TIA-222-G Axial Load,Pu2= 12,0 , s , i 4„0 ips(from 0.9D+1.6W)•* Use 1.3 Load Factor? ■o,, ,, - OTMu= 499.0-'' - '0 -ft @ Ground Load Factor= 1.00 'Axial Load,Put will be used for Soil Compression Analysis. **Axial Load,Pu2 will be used for Steel Analysis. Drilled Pier Parameters Safety Factor m Factor Diameter= 5 Soil Lateral Resistance= 11 - ' 0001 0.75 Height Above Grade= 0.5 ft Skin Friction= ,r;iiy;, i :iaDQY 0.75 Depth Below Grade= 15 End Bearing= 2.00_ 0.75 fc'= 3 ksi Concrete Wt.Resist Uplift= -T.2s '- - - ec= 0.003 in/in Load Combinations Checked per TIA-222-G Mat Ftdn.Cap Width= It 1.(0.75)Ult.Skin Friction+(0.75)Ult.End Bearing Mat Ftdn.Cap Length= ft +(1.2)Effective Soil Wt.-(1.2)Buoyant Conc.Wt.2 Comp. Depth Below Grade= ft 2.(0.75)Ult.Skin Friction+(0.9)Buoyant Conc.Wt.2 Uplift Steel Parameters Soil Parameters Number of Bars= 18 Water Table Depth= 99.00 t Rebar Size= #9 Depth to Ignore Soil= 2.50 1 Rebar Fy= 60 ksi Depth to Full Cohesion= 0 `t Rebar MOE= 29000 ksi Full Cohesion Starts at? Ground Tie Size= #5 Above Full Cohesion Lateral Resistance=4(Cohesion)(Dia)(H) Side Clear Cover to Ties= 3.311 in Below Full Cohesion Lateral Resistance=8(Cohesion)(Die)(H) Direct Embed Pole Shaft Parameters Maximum Capacity Ratios Dia @ Grade= in Maximum Soil Ratio= 110.0% Dia @ Depth Below Grade= in Maximum Steel Ratio= 105.0% Number of Sides= Thickness= in Fy= ksi Backfill Condition= Define Soil Layers Note:Cohesion=Undrained Shear Strenyh=Unconfined Compressive Strength/2 Friction Ultimate Comp.Ult. Tension Ult. Thickness Unit Weight Cohesion Angle End Bearing Skin Friction Skin Friction Depth Layer ft pcf psf degrees Soil Type psf psf psf ft 1 21 125 1000 25 Silt 5400 21 2 3 4 5 6 7 8 9 10 11 12 Soil Results: Overturn, inq Depth to COR= 10.08 ft,from Grade Shear,Vu= 8.00 sips Bending Moment,Mu= 579.66 k-ft,from COR Resisting Shear,mVn= 31.54 kips Resisting Moment,IMn= 2285.64 k-ft,from COR MOMENT RATIO= 25.4% OK SHEAR RATIO= 25.4% OK Soil Results: Uplift Soil Results: Compression Uplift,Tu= 0.00 kips Compression,Cu= 16.00 sips Uplift Capacity,mTn= 41.09 kips Comp.Capacity,Ei3Cn= 68.92 kips UPLIFT RATIO= 0.0% OK COMPRESSION RATIO= 23.2% OK Steel Results (ACI 318-08): Minimum Steel Area= 9.42 sq in Axial Load,Pu= 21.94 sips @ 3.25 ft Below Grade Actual Steel Area= 18.00 sq in Moment,Mu= 522.18 s-ft @ 3.25 ft Below Grade - Moment,cbMn= .. 1978.32 k-ft Axial,iPn(min)= -972.00 kips,Where(12Mn=0 k-ft n !axial,tiPn(max)= 4286.91,kips,Where mMn=0 k-ft MOMENT RATIO= 26.4/o OK v4.0-Effective:10-18-13 lc)Copyright 2013 by Pauli.Ford and Company,all rights reserved. Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral,transverse reinforcing Site Data Maximum Shaft Superimposed Forces BU#: 879570 TIA Revision: G Site Name: WASHINGTON SQUARE MALL Max. Factored Shaft Mu: 522.18 ft-kips(*Note) App#: Max. Factored Shaft Pu: 21.94 kips Max Axial Force Type: Comp. (*) Note: Max Shaft Superimposed Moment does not necessarily Loads Already Factored equal to the shaft top reaction moment For M(WL) 1 <----Disregard For P(DL) 1 <----Disregard Load Factor Shaft Factored Loads 1.00 Mu: 522.18 ft-kips Pier Properties 1.00 Pu: 21.94 kips Concrete: Pier Diameter= 5.0 ,ft Material Properties Concrete Area = 2827.4 in2 Concrete Comp.strength,fc= 3000 psi Reinforcement yield strength, Fy= 60 ksi Reinforcement: Reinforcing Modulus of Elasticity, E= 29000 ksi Clear Cover to Tie= 3.31 in Reinforcement yield strain = 0.00207 Horiz. Tie Bar Size= 5 Limiting compressive strain =I 0.003 Vert. Cage Diameter= 4.25 ft ACI 318 Code Vert. Cage Diameter= 51.00 in Select Analysis ACI Code=l 2008 Vertical Bar Size = 9 Seismic Properties Bar Diameter= 1.13 in Seismic Design Category= D Bar Area = 1 in2 Seismic Risk= High Number of Bars = 18 As Total= 18 in 2 Solve <--Press Upon Completing All Input A s/Aconc, Rho: 0.0064 0.64% (Run) ACI 10.5 , ACI 21.10.4, and IBC 1810. Results: Min As for Flexural, Tension Controlled, Shafts: Governing Orientation Case: 2 (3)*(Sgrt(f c)/Fy: 0.0027 200/Fy: 0.0033 �� Mu /7�•`�11 rAr ■e. - - - Case 1 Case 2 Dist. From Edge to Neutral Axis: 10.50 in Extreme Steel Strain, et: 0.0127 Minimum Rho Check: et> 0.0050, Tension Controlled Actual Req'd Min. Rho: 0.33% Flexural Reduction Factor,cp: 0.900 Provided Rho: 0.64% OK Ref. Shaft Max Axial Capacities, 4 Max(Pn or Tn): Max Pu = (c)=0.65) Pn. Output Note: Negative Pu=Tension Pn per ACI 318(10-2) 4286.91 kips For Axial Compression, cp Pn = Pu: 21.94 kips at Mu=(4=0.65)Mn= 1841.69 _ft-kips Drilled Shaft Moment Capacity, cpMn: 1978.32 ft-kips Drilled Shaft Superimposed Mu: 522.18 ft-kips Max Tu, (cp=0.9)Tn = 972 kips at Mu=4=(0.90)Mn= 0.00 ft-kips (MuhpMn, Drilled Shaft Flexure CSR: I 26.4% Drilled_Shaft Moment_Capacity, DSMC, Version 1.1 - Effective 04/01/2010 Analysis Date: 3/16/2015