Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
n CITY OF TIGARD REROOF PERMIT lig I • COMMUNITY DEVELOPMENT Permit#: RER2015 00023 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/03/2015 T c;A R D g Parcel: 2S 102 BD02600 Jurisdiction: Tigard Site address: 12977 SW PACIFIC HWY Project: Kim Subdivision: NORTH TIGARDVILLE ADDITION Lot: 37 Project Description: Reroof-Clean existing 1 layer of BUR roofing,install FR-10 fire sheet over existing BUR,install 60 mil TPO roof assembly over fire sheet. Some rigid insulation will be installed in areas of ponding water to eliminate the ponding. Contractor: J VAUGHAN INC Owner: KIM, PENNEY 2123 NW ALOCLECK DR#1203 395 NW SILVERADO DR HILLSBORO, OR 97124 BEAVERTON, OR 97006 PHONE: 503-690-1807 PHONE: FAX: 503-690-9905 FEES Description Date Amount Permit Fee 06/03/2015 $553.13 Specifics: 12%State Surcharge-Building 06/03/2015 $66.38 Info Process/Archiving-Sm$0.50(up to 06/03/2015 $1.50 Type of Use: COM 11x17) Class of Work: OTR Type of Const: Occupancy Load: Stories: Height: 0 ft Project Valuation: $33,245.00 General Information Building Area: 0 Re-Roof Area: 0 Roof Class: Tear Off: No Overlay: Existing Roof Layers: 1 Parapets: Total $621.01 Required Items and Reports(Conditions) This permit .c i%%, -• subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be do in accordance ith approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 day ATTENTION: Oreg•n la • ires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 95 -001-0010 through OAR •• -001-00" ou may obtain a copy of the rules or direct questions to OUNC by calling 503.23 987 or 1.:00.332.2344. I ued By: I A / I ` Permittee Signature: Ali Call 503.639.4175 by 7:00 a.m.for the next available inspectio date This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Re-Roof �LCEIVEP FOR OFFICE USE ONLI Received Ey" City of Tigard 94 — 3 201 a PennitNo.: A ,A.a _tO • 13125 SW Hall Blvd.,Tigard,OR 5 Plan Review Phone: 503.718.2439 Fax: 503.1598.1960 Date/B : Other Permit: T I GA RD Inspection Line: 503.639.4175 (ATV OF I l BAR'` Date Ready/By: mris ® See Page 2 for Internet: www.tigard-or.gov DTI U „a/ Notified/Method: Supplemental Information ►n l ,ilv: nt rIclo, TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ®Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑ Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 12977 SW Pacific Hwy New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:David Kim Covered porch area: square feet Cross street/directions to job site:Just west of Walnut Street Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. New Roof Installation Valuation: S$33,245.00 Existing building area: 4,699 square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) l a\:I ) New: 0 APPLICANT ❑ CONTACT PERSON NOTICE Business name:J.Vaughan,Inc. All contractors and subcontractors are required to be Contact name:Pedro Cruz licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:2123 NW Aloclek Dr.#1203 jurisdiction in which work is being performed.If the City/State/ZIP:Hillsboro,OR 97124 applicant is exempt from licensing,the following reasons apply: Phone:(503)690-1807 Fax::(503)690-9905 E-mail:info @orion-ow.com CONTRACTOR Business name:J.Vaughan,Inc., BUILDING PERMIT FEES* Address:2123 NW Aloclek Dr.#1203 (Please refer ro1ee schedule) Structural plan review fee(or deposit): City/State/ZIP:Hillsboro,OR 97124 FLS plan review fee(if applicable): Phone:(503)690-1807 Fax:(503)690-9905 CCB lic.:88412 2// i 7 Total fees due upon application: f Amount received: 470V,47/ Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Pedro Cruz Date:6-03-15 * Fee methodology set by Tri-County Building Industry Service Board. I\Building\Permits\ROOF-PermitApp.doc 10/01/09 440-4613T(11/02/COM/WEB) City of Tigard: Re-Roofing Permit Checklist Page 2-Supplemental Information RESIDENTIAL (One- & Two-Family Dwelling) ❑ REPAIR(major)plan review required by plans examiner: building permit is required when structural changes are made or the space sheathing is removed or replaced. SUBMIT TWO(2) SETS OF PLANS SPECIFYING: A. Roof area and nearest street. B. Attic vents: Provide 1 sq. ft. for each 150 sq. ft. of attic space. Vents shall be located in the upper 1/3 of the roof. Provide 1 sq. ft. for each 300 sq. ft. when eave and attic venting is provided. Note: No permit is required for residential re-roof if not more than two (2) layers of roofing will exist upon completion of the re-roofing. COMMERCIAL (includes multi-family and condominiums) ❑ RE-ROOF: Pre-inspection is required for all roofs sloped 2:12 and less. Please make an appointment by calling the Building Division at 503.718.2439. ❑ PLAN REVIEW: Note: Depending on the conditions noted at the pre-inspection, plans may be required to address any non-conforming items. VALUATION OF PROJECT: $ sq.ft. of roof area Permit Fee based on valuation: $ (see Building Permit Fees chart) 12% State Surcharge: $ 65% Plan Review Fee: $ (Required for major repairs of residential and special purpose roofing of commercial projects.) TOTAL: $ C:\Users\Jason\Desktop\David Kim\ROOF_PermitApp.doc 2 RECEIVEP Site Map JUN - 3 2015 CITY Of I HJAKD BUILDING DIVISION / / i '\.. 1.6'. - -111, la'N// f \ y '�, - t ncke Wi 's I,, /� • a/ `may \ f .7 .0 / N� 11%4 4..._. .---- -- ‘ :d/ / C€case pre .� , '. ,o,„,,"� ■ / 441/.0 ::. k. '.....: Project Location: 12977 SW Pacific Hwy. Tigard, OR 97223 Roof Contractor: J. Vaughan, Inc. (Orion Roofing and Sheet Metal, DBA) Project Name/Owner: David Kim Roof Area Included: 37' x 127' = 4,699 sq.ft Project Valuation: $33,245.00 Scope of Work: Clean existing 1 layer of BUR roofing, install FR-10 Fire Sheet over existing BUR, install 60 mil. TPO roof assembly over Fire Sheet. Some rigid insulation will be installed in areas of ponding water to help eliminate the ponding. Roof Material to be installed: GAF 60 mil TPO Roof Membrane. UL List and Rating: TGFU-R1306, maintains existing class A fire rating with use of Atlas FR-10 Fire Sheet over existing BUR • • NON-INSULATED TPO MECHANICALLY ATTACHED SYSTEMS SPECIFICATION PLATE Membrane Type Construction type Insulation —EvERGUARDMEMBiwIE T= TPO N=New I=Insulated P= PVC R=Recover N=Non-Insilated E= EPDM T=Tear-Off(Complete) — MILL TEC FASIENENS � 1 1 3 oz co 6oz POLYMAT Woo*mowed) AAA . T MA R N 60FB 1 i I Membrane (thickness and type) Membrane Attachment 45= 45 mil Smooth MA=Mecharically Attached 60= 60 mil Smooth DEC1VEXISTING MEMBRANE FA= Fully Adhered 60= 80 mil Smooth BA=Ballast Applied 45FB= 45 mil Fleece Bad<ed 60FB= 60 mil Fleece Bad<ed BOFB= 80 mil Fleece Bad<ed Specification Attachment Construction Insulation TPO Guarantee Number Type Type Thickness Length Up To (Years) T-MA-N-N-45 .045 12 T-MA-N-N-60 Mechanically New No .060 15 T-MA-N-N-80 Attached .080 20 T-MA-T-N-45 .045 12 T-MA-T-N-60 Mechanically Tear Off No .060 15 T-MA-T-N-80 Attached .080 20 T MA R N 45 Mechanically Recover No* _ 045 12 T-MA-R-N-60 Attached .060 15 — T-MA-R-N-80 .080 20 T-MA-N-N-45FB .045 FB 12 Mechanically New No T-MA-N-N-60FB Attached .060 FB 15 T-MA-N-N-80FB .080FB 20 T-MA-T-N-45FB .045 FB 12 Mechanically Tear Off No T-MA-T-N-60FB Attached .060 FB 15 T-MA-T-N-80FB .080FB 20 T-MA-R-N-45FB .045 FB 12 T MA R N 60FB Mechanically Recover No Attached 060 FB 15 T-MA-R-N-80FB .080FB 20 Separator Sheet required;3/6 oz polymat or StormSafe'". Refer to Insulation Attachment and Membrane Attachment Tables for attachment requirements. Mechanically attached systems require the use of half sheets. 77 EverGuard® TPO 60 mil Membrane Applicable Standards UL Listed, FM Approved, Miami-Dade County Approved, Florida Building Code Approved, CRRC Listed, Title 24 Compliant', ENERGY STAR®Qualified",ASTM D6878. Physical Properties ASTM Test Method ASTM D6878 Minimum EverGuard' Typical Test Data 1.Certain data is provided in MD(machine direction)x CMD(cross machine direction)format. 2. Data is based upon typical product performance,and is subject to normal manufacturing tolerance and variance. Nominal Thickness ASTM D751 0.039"(min.)(0.99 mm) 0.060"(1.52 mm) Breaking Strength ASTM D751 Grob Method 220 lbf/in.(38.5 kn/m) 305 lbf x 290 lbf(454 x 432 kg/m) Factory Seam Strength ASTM D751 66 lbf(98.34 kg/m) 135 lbf(membrane failure)(201.1 kg/m) Elongation at Bra.' ASTM D751 15% 30% Heat Aging ASTM D573 90%Retention of Breaking Strength 100% and Elongation at Break Tear Strength ASTM D751 8"x 8"(203 x 203 mm)Sample 55 lbf(81.95 kg/m) 75 lbf x 130 lbf(1 1 1.8 x 193.7 kg/m) Puncture Resistance FTM 101C Method 2031 Not Established 380 lbs. (172 kg) Cold Brittleness ASTM D2137 -40 C -40C Permeance ASTM E96 Not Established 0.08 Perms Dimensional Change ASTM D1204 0158 F(70 C),6 hrs. +/-1% 0.4% Water Absorption ASTM D471 1158 F(70C), 1 week +/-3.0%(top coating only) 0.7% Hydrostatic Resistance ASTM D751 Method D Not Established 430 psi Ozone Resistance ASTM D 1 149 No visible deterioration @ 7 x No visible deterioration 0 7 x magnification magnification Reflectivity(white)Initial/Aged ASTM C 1549 N/A 0.76/0.68 Emissivity(white)Initial/Aged ASTM C 1371 N/A 0.90/0.83 Weather Resistance ASTM G155/D6878 10,080 IW(m2-nm)at 340 nm >25,000 Ig/(m2.nm)at 340 nm Heat Aging ASTM D573 240 F(1 15 C)for 32 weeks 60 weeks Thickness Above Scrim ASTM D7635 Min 30%of Total Thickness 22.1"(561 mm)(Nominal) Guarantee Up to 25 years *White, Energy Gray, and Energy Tan Membranes Only **ENERGY STAR only valid in the USA Product Data Roll Size Note: Product sizes, dimensions, and widths are nominal values and are subject to normal manufacturing/packaging tolerance and variation. Colors Full Size Roll Full Roll Weight Half Roll Size Half Roll Weight White, Tan, Gray, 10'x 100' 322 lbs. (146 kg) 5' x 100' 162 lbs (73.5 kg) Energy Tan, 13.05 x 30.5 m) (1.52 x 30.5 m) Energy Gray (1,000 sq. ft. (500 sq. ft. [92.9 sq.m]) [46.5 sq.m]) 8'x 100' 257 lbs. (1 17 kg) 4'x 100' 128.8 lbs. (58 4 H (2.44 x 30.5 m) (1.21 x 30.5 m) (800 sq.ft. (400 sq. ft. [74.3 sq.m]) [37.1 sq.m]) Note: Membrane rolls shipped horizontally on pallets, stacked pyramid-style and banded. Storage Store rolls on their sides on pallets or shelving in a dry area. Safety Warning Membrane rolls are heavy. Position and install by at least two people. GAFQuality You Can Trust... From North America's C�m f" Largest Roofing Manufacturer!'" 9 a ©2014 GAF 1I/14 • Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12977 SW PACIFIC HWY, TIGARD, OR, 97223 Commericial - Reroof 299 Final inspection PASS - No C of O RER2015-00023 Chip Barnett Violation Summary: Inspector Contractor