Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
�x r,� , �,: - 7 NJ 6C 2010 OuS2 3 DIMENSIONS — SFHA 21/2-4 RECEIVED LL i ! yy_______ .i �� fL___, - W C T 2 2 2010 ' �= LvEnGARD I �;DIN c�... � . I 13% i 114 A I FIGURE 18-2 1�3ti I �/ FIGURE 16-1! 333 / FIGURE 16-3 H".--...'--1 67/11.1 .„ „.,,, , .,....„ - - I-.... .„./ 34 N.P.T. ' DRAIN CONN. --/ f PIPES PORTS FURNISHED BY OTHERS I 2 III /IF.-- 6%; 1 /,6/ 301x MOUNTING HOLES . irmig I ,' �' .� SIDE VIEW END VIEW ›\ v 1 2 x 2 NAILING STRIP 4 FIGURE 18-4 L FIGURE 16-1 Page 15 A SFHA 25-30,35-40 Unit Dimensions ......,....1,,,..../ SFHA 25-30 3540 9 L 58% 7014 W W 3234 38Y4 4�► A 2314 27 B 16 2334 C 1414 1414 . 2'iv Net Wt. - 445 550 I FIGURE 16-2 Page 16—SFHA 25-40 Supply- Return Casing Dimensions `� SFHA 25-30 35-40 L 4314 57 4 W 361 42'14 A 34 2734 FIGURE 18-5 FIGURE Net 18 Wt. 3 Page 18180 225 ' I` Outside Air&Economizer Intake Hood i��+:�0 0'�� aIU Aq SFHA 25-30 3540 .LL�.�.II [►�1►��►�r L 34 4734 OA Net Wt. 56 76 / Econ.Net Wt. 92 100 FIGURE 18-4 Pa a 18—Real Curb 60 SFHA 2530 35.40 L 41% 551 �, W 3634 4234 A 49'K 83K Pt B 2834 3436 Net Wt. 56 74 1 FIGURE 18-5 Pave 16—Concentric Duct I SFHA 25-30 35-40 L . 211 271 I CONCENTRIC W 21 27 DIFFUSER A 15 18 8 15 18 Net Wt. 60 75 16 i A V' U Z rn O 10 OU' ' Cl -.. n m I ig CP i rn 1 az PI ci)g a- g- i PROJECT: w R£ITMEIER MECHANICAL 19570 SW 9679 Cr IALO 1 IAL TWUnR,OR 97062 atarra•r.•eampswirew PN.(503)603-0205, FAX(503)603-0150 r M111Irew•mLLilI CCB.153770-WA.Cog R.1..IO..REITM1•97291 SIDE DISCHARGE DETAIL RECEIVED TRANE' Proposal OCT 2 2 2010 CITY OF TIGARD • PROPRIETARY AND CONFIDENTIAL PROPERTY OF Trane U.S. l $UIU ING DIVISION DISTRIBUTION TO OTHER THAN THE NAMED RECIPIENT IS PROHIBITED (�2010 Trane All rights reserved Prepared For: Date:October 19, 2010 Matt Rogers Reitmeier Proposal Number:Y2-44775-1 Job Name: Engineer: Willowbrook Design-build Delivery Terms: Payment Terms: Freight Allowed and Prepaid- F.O.B. Factory Net 30 Days Trane U.S. Inc. is pleased to provide the enclosed proposal for your review and approval. Tag Data- 1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A(Qty: 2) Item Tag(s) Qty Description Model Number Al D-7 1 3 ton Pkgd. Gas/Elec. Rooftop Conver 4YCC3036A3075 Product Data-1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A All Units Standard ship cycle Gas Electric, R-410A Refrigerant 208-230/3/60 Filter frame (Fld) 0 -100% Mod. economizer-horizontal (Fld) Item: Al Qty: 1 Tag(s): D-7 3 Tons 13 SEER 75,000 Btuh LESS(or by others): Installation, Start-up, Labor warranty, Disconnect, Smoke detector, Thermostat, Curbs, Seismic. Total Net Price (Excluding Sales Tax) • See attached unit cutsheets Sincerely, Daniel Driver-Trane U.S. Inc. Phone: (503) 620-8031 Fax: (503) 639-1454 This proposal is subject to your acceptance of the attached Trane terms and conditions. J:I JOBS 1 124144775111 prop ver 1.doc Willowbrook October 19,2010 Unit Dimensions- 1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A Item: Al Qty: 1 Tag(s): D-7 INLET FAN GRILLE • b 7 7/8 FLUE HOOD :j :: �\' ( ��/, ."-=�Av.>.1v , INLET I i)))1)I IlI,) -. INLET 41 5/16" � ////j • r- -I r / Y� 1Y / I SUPPLY _ L RETURN r.T 12" Abille&BS L____J L____J 4 INLET (DUCT FLANGE) 3 3/16"-- 16" ■ •5/8" 3 3/16" 16" 7" 3 7/8"-1 48 13/16" UNIT-TOP VIEW UNIT-BOTTOM PENETRATION VIEW tIUDi ]J_WilI 11/16" ` 11 7720 11/16• 18 -- 9/16" 11 11/16' SUPPLY RETURNX SECTION X-X ���-`�■- TYPICAL(6)SIDES OF SECTION Y-Y I SIDEFLOW DUCT OPENINGS TYPICAL(8)SIDES OF 2 5/16" DOWNFLOW DUCT OPENINGS 35/16" 1511/16--615/16".-15 11/16' 73/16"-•- UNIT-BACK AND PENETRATION VIEW AIR FLOW I- -_i_t_rr - 24V ENTRY _- IITlI 1 llIU.O 359/16 HORIZONTAL 14 316'11 9/16" - AIR FLOW i !Jl4 i ' . _ POWER ENTRY 25.4011 1 DIA.HOLE 1" ONDENSATE RAIN FOR 3 3/8" II AS LINE ENTRY FOR 12.70[1/21 N.P.T. 18 11/16'--1 199(3/41 FEMALE NPT I GAS CONNECTION • 3 7/8" 5" UNIT-RIGHT SIDE VIEW UNIT-LEFT SIDE VIEW FLD=Furnished by Trane U.S.Inc./Installed by Equipment Proposal Page 2 of 12 Others Willowbrook October 19,2010 Unit Dimensions - 1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A Item: Al Qty: 1 Tag(s): D-7 ELECTRICAL/GENERAL DATA POWER CONNECTION COMPRESSOR Model: '4YCC3036A3075 Voltage Range: 208-230/3/60 Min.Circuit Ampacity: 18.5 Number: '1 Max.Circuit Breaker: 30.0 Phase: 3 Prot.Rtg.Recmd: 30.0 Rated Load Amps: 11.5 ERR/SEER 11.0/13.0 Locked Rotor Amps: 77.0 Noise Rating#: 75.0 GAS HEAT 'Type of Gas:NATURAL OUTDOOR MOTOR Capacity BTUH: 75000 Number: '1 Temp.Rise F(Min./Mix): 30-60 Horsepower: 020 Gas Size Pipe: 1/2" Phase 1 Full Load Amps: 1.1 Locked Rotor Amps: 1.9 REFRIGERANT INDOOR MOTOR .R-410A Number: 1 Type. Horsepower: 0.50 Factory Charge 1075 Circuit#t: 7.8 lb Motor Speed(RPM): Phase 1 Full Load Amps: 2.98 Locked Rotor Amps: 6.7 NOTES: 1. Capacity rated in accordance with A.R.I.Standard 210/240. Noise rated in accordance with A.R.I.standard 270. A.R.I.standard rating conditions are: 80 D.B.67 W.B.entering air to indoor coil 95 D.B.entering air to outdoor coil. 2. All models are U.L.listed. Ratings shown are for elevations up to 2000 feet. For higher elevations reduce ratings at the rate o14 percent per 1000 feet elevation. 3. Based on U.S.Government Standard Tests. 4. Unit ships on high input and is convertible to low input with a low fire accessory kit. 5. Convertible to LPG with orifice change. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Proposal Page 3 of 12 Others Willowbrook October 19,2010 Weight, Clearance & Rigging Diagram- 1.5-5 ton Pkgd.Gas/Elec. Rooftop Convert. R-410A Item: Al Qty: 1 Tag(s): D-7 B W3 W6 • Wt Itl((eit W2, il)71.. i= - .II. �� • FLUE HOOD W4 W5 CENTER OF GRAVITY UNIT WEIGHT CORNER WEIGHT CENTER OF GRAVITY SHIPPING NET WI W2 W3 W4 W5 W6 A B '488.0 lb '392.0 lb 214.0 lb '178.0 lb '80.0 lb '133.0 lb '111.0 lb '67.0 lb '22" 25' CLEARANCE TO COMBUSTIBLE MATERIAL RECOMMENDED SERVICE CLEARANCE BOTTOM 0 UNIT WITH O.A.DAMPER/ECON. WITH 2 POS.DAMPER BACK SIDE 1" BACK SIDE 12" 24" LEFT SIDE 6" LEFT SIDE 36' 42" RIGHT SIDE 6" RIGHT SIDE 42" FRONT SIDE 12' FRONT SIDE 42" . TOP 36" LIFTING LUG KITS FOUR REUSABLE LUGS IN EACH KIT ALLOW UNITS TO BE EASILY LIFTED TO ROOFTOP INSTALLATIONS. THESE LUGS SNAP(NO SCREWS REQUIRED)INTO SLOTS IN THE UNIT DRIP LIP CHANNEL FLD=Furnished by Trane U.S. Inc./Installed by Equipment Proposal Page 6 of 12 Others Willowbrook October 19,2010 Accessory- 1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A Item: Al Qty: 1 Tag(s): D-7 T 20" 22' 16 7/6" 1[1k 15" HORIZONTAL ECONOMIZER AND RAIN HOOD FLD=Furnished by Trane U.S. Inc./Installed by Equipment Proposal Page 8 of 12 Others General Data MODEL 4YCC3036A3075A 4YCC3036A3096A 4YCC3036A4064A 4YCC3036A4075A 4YCC3036A4096A RATED Volts/PH/Hz 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 Performance Cooling BTUH D 35000 35000 35000 35000 35000 Indoor Airflow(CFM) 1200 1200 1200 1200 1200 Power Input(KW) 3.284 3.284 3.284 3.284 3.284 EER/SEER (BTU/Watt-Hr.) 11.0/110 11.0/110 1t0/110 1t0/110 11.0/110 Sound Power Rating [dB(A)1O 75 75 75 75 75 Performance Heating® . Input BTUH(Natural Gas)O 75000 96000 64000 75000 96000 AFUE 80.0 80.0 80.0 80.0 80.0 Temp. Rise-Min/Max(`F) 30/60 40/70 25/55 30/60 40/70 Orifice Qty/Drill Size(Natural Gas) 2/#33 3/#37 2/#37 2/#33 3/#37 POWER CONN.-V/PH/HZ 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 Min.Brch. Cir.Ampacity 18.5 18.5 8.7 8.7 8.7 Fuse Size-Max.(amps) 30 30 15 15 15 Fuse Size-Recmd. (amps) 30 30 15 15 15 COMPRESSOR SCROLL SCROLL SCROLL SCROLL SCROLL Volts/Ph/Hz 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 R.L.Amps-L.R.Amps 11.5/77 11.5/77 5.13/35 5.13/35 5.13/35 OUTDOOR COIL-TYPE SPINE-FIN SPINE-FIN SPINE-FIN SPINE-FIN SPINE-FIN Rows/F.P.I. 2/24 2/24 2/24 2/24 2/24 Face Area(sq.ft.) 13.32 13.32 13.32 13.32 13.32 Tube Size (in.) 3/8 3/8 3/8 3/8 3/8 INDOOR COIL-TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows/F.P.I. 4/15 4/15 4/15 4/15 4/15 Face Area(sq.ft.) 3.54 3.54 3.54 3.54 3.54 Tube Size(in.) 3/8 3/8 3/8 3/8 3/8 Refrigerant Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE Drain Conn.Sizelin 1 3/4 FEMALE NPT 3/4 FEMALE NPT_ 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN-TYPE PROPELLER PROPELLER PROPELLER PROPELLER PROPELLER Dia. (in.) 23 23 23 23 23 Drive/No. Speeds DIRECT/1 DIRECT/1 DIRECT/1 DIRECT/1 DIRECT/1 CFM®0.0 in.w.g.® 3240 3240 3240 3240 3240 Motor-HP/R.P.M. 1/5/830 1/5/830 1/5/830 1/5/830 1/5/830 Volts/Ph/Hz 208-230/1/60 208-230/1/60 460/1/60 460/1/60 460/1/60 F.L.Amps/L.R. Amps 1.1 /1.9 1.1 /1.9 0.6/1.3 0.6/1.3 0.6/1.3 INDOOR FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL DiaxWidth(in.) 10X10 10X10 10X10 10X10 10X10 Drive/No. Speeds DIRECT/2 DIRECT/2 DIRECT/2 DIRECT/2 DIRECT/2 CFM©0.0 in.w.g.® SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor-HP/R.P.M. 1/2/1075 1/2/1075 1/2/1075 1/2/1075 1/2/1075 Volts/Ph/Hz 200-230/1/60 200-230/1/60 460/1/60 460/1/60 460/1/60 • F.L.Amps/L.R.Amps 2.98/6.7 2.98/6.7 1.7/3.12 1.7/3.12 1.7/3.12 COMBUSTION FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive/No. Speeds DIRECT/1 DIRECT/1 DIRECT/1 DIRECT/1 DIRECT/1 Motor-HP/R.P.M. 1/35/3480 1/35/3480 1/35/3480 1/35/3480 1/35/3480 Volts/Ph/Hz 208-230/1/60 208-230/1/60 460/1/60 460/1/60 460/1/60 FLA 0.53 0.53 0.25 0.25 0.25 FILTER/FURNISHED NO NO NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY THROWAWAY Recmd. Face Area(sq.ft.)© 4.0 4.0 4.0 4.0 4.0 REFRIGERANT R410A R410A R410A R410A R410A Charge (Ibs.)O 7.75 7.75 7.75 7.75 7.75 GAS PIPE SIZE(in.) 1/2 1/2 1/2 1/2 1/2 DIMENSIONS HXWXL HXWXL HXWXL HXWXL HXWXL Crated (in.) 45.86/44.5/52.03 45.86/44.5/52.03 45.86/44.5/52.03 45.86/44.5/52.03 45.86/44.5/52.03 WEIGHT Shipping(lbs.)/Net(lbs.) 488/392 493/397 488/392 488/392 493/397 ()Rated in accordance with A.R.I.Standard 210/240.A.R.I.standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. 0 All models are certified to UL 1995.Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation. . 0 Convertible to LPG. 0 This value is approximate.For more precise value,see Unit Nameplate. 0 Based on U.S.Government Standard Tests. 0 Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05'.W.C.0.05"W.C. 0 Sound Power values are not adjusted for ARI270-95 tonal corrections. OO Standard Air-Dry Coil-Outdoor. 8