Loading...
Report 2ols- o 0 / PHASE1 - CELLULAR SIGNALS TRANSMISSION (EXISTING FIRE ALARM SYSTEM) SUBMITTAL GUIDE AECEIVEP DEC 312014 CITY OF l( AKV BUILDING DIVISION THE RESERVE AT ASHBROOK 9346 SW MANDAMUS CT TIGARD, OR 97223 Prepared By: PERFORMANCE SYSTEMS INTEGRATION 7324 SW Durham Road Portland, Oregon 97224 info@psintegrated.com (503) 641-2222 Phone (503) 641-1464 Fax 12/30/2014 0:1 ''' . 71111.11=111 ■ A 4:5 0 a 'r Search dmpatarms Powerful addressable fire system /-II I �' in WI IIIII IM �EP 00 • Proven reliability suitable for commercial and industrial installations ' • On-Board 10/100 Network Communication • Full range of zone expansion.communication,and • relay output capability • Flash Updateable:No more firmware chips to replace • Adaptive TechnologyTA"—Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XR150FC/XR550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES • Up to 562 two-wire smoke detector or fire initiating zones on • Multiple on-board status LEDs XR550FC • Up to 100 output schedules to control relays and panel outputs • Up to 142 two-wire smoke detector or fire initiating zones on • 32 individual reporting areas,with common areas XR150FC • Output Groups:Maximum functionality—Minimum programming • Up to.5 Amps 12 VDC smoke and auxiliary output with OVC protection XR15 "'NFC/Xr trusi n ire I Access 'Net work tel uter XR150FC & XR550FC FIRE PANELS The XR150DFC and XR550DFC provide basic fire monitoring for any single site application.The XR150DNFC and XR550DNFC panels provide all the same basic fire monitoring as the XR150DFC and XR550DFC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM.Both panels come fully assembled from the factory with the following components: CONTROL PANE. The XR150FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACT. NET.or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion. conventional and addressable smoke detectors,pull stations,and heat detectors. The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation.For added security,the enclosure comes with a lock and key. KFYPAI) ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC,56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. XR150FC/XR550FC TYPICAL NOTIFICATION/ANNUNCIATION 12 or 24 VDC F'RE NAC 1 12 or 24 VDC NAC 1 Sync Module Strobe Mini-Horn 12or24VDC I NAC 2 1 12 or 24 VDC Power Supply Sync Module Horn Strobe NAC 2 505-12 or other 12/24VDC UL Motor Bell Commercial Fire Approved Digital "= Digital SLC Power Supplies Annunciator Bus .; soun_- Loop 2 " Digital SLC i:O: Additional 630F sem Any expansion device Loop 1 is. Fire Command can operate on SLC Loop Centers 1 or 2 630F Fire Command Center FLEXIBLE COMMUNICATION NETWORK OR CELLULAR The XR150DNFC and XR550DNFC COMMUNICATION has transitioned from dialer-focused Built-in 10/100 auto-sensing Ethernet The check-in and fail time settings are communications to a true network and connection enhances both standard and programmed for five minutes.As the backup cellular communications approach by encrypted line security options.Both UDP and path,the 263C or 263H provides the security providing stronger. multi-layered panel TCP are supported.The network option can of a communication link that continues to communications that ensure a constant be used as the primary or backup path to the function, even when land lines are cut or link between the panel and Central Station. digital dialer or cellular option. compromised. The communicators can be Installers have the ability to create,configure The XR150FC and XR550FC Series Panels used as a stand-alone communicator without and manage up to eight communication may be used with the 263C or 263H Digital the need for a backup.This interface works on paths. Cellular Communicator as the primary path digital Cellular data networks over a variety of The unique DMP Serial 3 format supports 16 (no backup required) for commercial fire carriers in the USA and Canada. or 32-character user, zone and area names installations. to decrease the central station response time and limit dependence on automation literal tables for message conversion. EIGHT COMMUNICATION PATHS NOTIFICATION CIRCUIT ')UTPUTS Create, configure, and manage up to eight EXPANSION The XR150FC and XR550FC allow the use communication paths between the panel and Easily add NAC outputs to the XR150FC/ of two SPOT relay outputs and four open Central Station.Each path has its own panel XR550FC system.Up to three Class B modules collector outputs, that may be activated by communication programming parameters, can be mounted within the FACP.Model865 or zone or system events,by schedule,through and can be identified as either primary or 866 Class B NAC Modules may be combined the User Menu or when a card is presented. backup.This enables installers to configure a with a power supply to provide additional 4 Output Groups allow multiple outputs to reliable communication link,offering greater Amp NAC outputs. Use an 867 on the SLC activate with a single event and/or can be confidence that the panel will always be Loop to further expand NAC circuits. assigned to a particular user profile. connected to the Central Station. OUTPUT SCHEDULES FIRE DRILL AND ONE-MAN COMMUNICATION FUNCTION WALK TEST Achieve maximum system flexibility with DIAGNOSTICS Users can test fire notification bells using 100 programmable schedules that simplify The enhanced diagnostic menu enables the Fire Drill feature. A special code is also planning and operations. Control any technicians to check network and cellular available for installers to test the system.The contact activated device with schedules that communication status, cell signal strength, one-man walk test feature allows a single automatically regulate relays and switched and email status from the keypad. technician to check the panel response to ground outputs. fire,burglary.panic and supervisory zones. MULTI-LINGUAL DISPLAYS FIRE ZONE PROGRAMMING For additional flexibility,keypads attached to Program zones for fire,fire verify,fire retard, 3UILT IN PROGRAMMER ry' yP presignal,cross zoning, or fire supervisory. AND DIAGNOSTICS the XR150FC and XR550FC panels can display This flexibility allows the ability to match No programming device is required.enabling keypad Status List and User Menu text using individual zone characteristics to the needs installers and service technicians to fully multiple languages.The user has the option of any area in the fire installation. program the system and run diagnostics from to select the language to use. any DMP LCD keypad. Check the electrical STATUS LIST ZONE EXPANSOOl' state of zones,find individual zone numbers. To provide maximum system flexibility, fire The XR150FC and XR550FC provide up to 570 check the LX-Bus for Missing, Overlapping zones may be programmed to display at a zones, programmable for a variety of fire and/or Extra zones,and much more.all from applications. The system provides Class B any DMP LCD keypad. specific keypad.In this manner,all fire zones can be monitored in one location and other 12 VDC powered zones, two on-board and four on the 715 Module, plus eight panel RASH UPDATEARI.% zones can be programmed to display and be burglary zones.Up to 60 zones are available The XR150FC and XR550FC panels accept monitored at different keypad locations. on 15 keypad addresses and up to 100 zones software updates from a remote location 2,000 EVENT MEMORY are available on each built-in LX-Bus TM using using Remote LinkTM software. When new Allows the user to view the last 10.000 Expansion Modules. XR150FC/XR550FC feature updates release. door accesses or 2.000 system events that perform the flash update remotely. occurred over the past 45 days. FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. The Remote Link programming software When a Fire Verify zone initiates an alarm, takes advantage of the easy-to-use simplicity the panel performs a Sensor Reset. If any of Microsoft®Windowsmi.The XR150FC and Fire Verify zone initiates an alarm within 120 XR550FC include an interface connection for seconds after the reset,an alarm is indicated. installers to use to connect a laptop computer. If an alarm is initiated after another 120 seconds.the cycle is repeated. • • POWER SUPPLIES KEYPADS 505-12/LX 5 Amps©12 VDC DMP WI1 - ._SS 630F LCD Remote Fire Command 505-12L 5 Amps 4 12 VDC 1100X Receiver - 505-12A 5 Amps @ 12 VDC 1100XH High Power Receiver EXPANSION MODULES 1100R Repeater 710 Bus Splitter/Repeater PULL STATIONS 1103 Universal Transmitter, 711 Single Zone Expansion 850 Series Pull Stations External Contact 714 4-zone Class-B Expansion SMOKE/HEAT DETECTORS 1165 Commercial Smoke 714-8 8-zone Class-B Expansion 521 B/BXT Conventional Smoke.CleanMe Detector 714-16 16-zone Class-B Expansion 521LX/LXT Addressable Smoke/Heat. 1165H Commercial Smoke/Heat 715 4-zone 2-wire smoke Expansion CleanMe Detector 715-8 8-zone 2-wire smoke Expansion 1165HS Commercial Smoke/Heat 715-16 16-zone 2-wire smoke Expansion ACCESSORIES Detector with Sounder 716 Output Expansion, 270 Network Transient Suppressor 1181 Post Indicator Valve(UL) 4 Form C relays. 277 Commercial Fire Buzzer Module 1182 Outside Screw and Yoke Valve 4 open collector outputs 300 Four-wire Harness Supervisory Switch(UL) 717 Graphic Annunciator:20 open 303 Silence/Reset Push-Button 1183-135F Heat Detector collector outputs 305 Plug-in Output Relay 1183-135R Heat Detector CELLULAR COMMUNICATORS 306 Tamper Harness 1184 Carbon Monoxide Detector 307-S Screw-On Tamper Switch 263C CDMA Cellular Communicator 3012 Clip-On Tamper Switch 263H HSPA+Cellular Communicator 335 Intrusion Siren COMPUTER SOFTWARE 263HCAN HSPA+Cellular Communicator 370 Lightning Suppressor Remote Link Upload/Download (All require a 381 cable) 374 Surge Voltage Suppressor Programming Software AUXILIARY NV'1ULES 381-2 18"Coax Extension System Link End-User Management 860 Relay Output Module 431 Output Harness Software 865 Style W/X Notification Circuit Alarm Monitoring Module ty 861 Power Distribution Module Module Command Center Module 866 Style W Notification Circuit CENTRAL STATION RECEIVERS Advanced Reporting Module Module SCS-1R Network Enabled Receiver Account Groups Module 867 LX-Bus Notification Circuit Compatable with Central Station Link Server Application Module Receivers that accept Standard CID. 869 Style 0 Class A Initiating Circuit DD.or DMP Serial 3 messaging Module SCS-VR(Virtual Receiver) Software only 893A Dual Phone Line Module solution that runs on a server for network IP and cellular communications SYSTEM SPECIFICATIONS LISTINGS AND APPROVALS Primary Power(included) 16 VAC 56 VA transformer Refer to the XR150FC/XR550FC Installation Guide ILT-1297), XR150FC/ Secondary Power 12 VDC Battery XR550FC Programming Guide (LT-1232) and specific compliance listings Models 365,366.368 or 369 for installation and programming requirements necessary to meet a Output Rating particular approval. Bell Up to.7 Amps at 12 VDC FCC Part 68 Smoke and Auxiliary Up to.5 Amps at 12 VDC FCC Part 15 For UL installations,total bell,smoke,and auxiliary cannot Underwriters Laboratories(UL)Listed exceed 1.2 Amps using a 56 VA transformer. ANSI/UL 864 Fire Protective Signaling Current Draw 180mA IL— Enclosure: For approval information.access www.dmp.com and select Compliance. Material Cold-rolled steel(Red) —vy a ORDERI!■10 INrORM.ATION a XR150DFC-R XR150 Fire Control Panel XR150DNFC-R XR150 Fire Control Panel with o o - = Network s XR550DFC-R XR550 Fire Control Panel m = a XR550DNFC-R XR550 Fire Control Panel with w. Network o -am■ I 2500 North Partnership Boulevard 800.641.4282 dmp.com Springfield,Missouri 65803-8877 Designed.Engineered&Assembled • in Springfield.Missouri . Vr i ; o 011%131 i . vii s l - GN Yar . rIll A lift BATTERIES Werker SLA technology offers high-density power that out-performs traditional lead acid batteries. The Absorbed Glass Mat(AGM)construction is designed for efficient gas recombination and allows for maintenance-free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: Charger Features: • Werker SLA AGM batteries contain a proprietary grid alloy New! SLA Chargers formula.This formula combined with the advanced plate curing techniques offer improved performance. • Regulated trickle charge for"float"mode charging • Werker batteries contain a unique electrolyte formula with a • Short circuit protected special sub-colloid additive for higher reliability and longer life. • Reverse polarity protected • More than 1,000 discharge/recharge cycles. • Thermal protection in case of overload • The unique construction and sealing techniques of the Werker • Alligator clips battery guarantee leak-proof operation. • Color LED to indicate state of charger • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications,even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire production process. We r k e r.• ,9 oi, SkY SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Hams Capacity Dimensions Height Over Weight Item* Yoke Retada t AI) L x W x H Dal Taaia&lia.) (ws.) Mat t Volts Retardant AY L x W x H(in.) Teneisal tin.) (is.) WKAl2-0.8WL 12 - 0.8 3.78 x 0.98 x 2.40 2.4 0.8 WKAl2-7.5F2 12 - 7.5 5.94 x 2.56 x 3.74 3.98 6.0 WKAl2-1.3F 12 - 1.3 3.82 x 1.69 x 2.05 2.28 1.4 WKA1 2-1 2F2 12 - 12 5.94 x 3.90 x 3.74 3.98 9.3 WKAl2-2ST 12 - 2 5.91 x 0.79 x 3.54 3.54 1.7 WKAl2-18N8L 12 - 18 7 13 x 3.03 x 6.57 6.57 13.9 WKA1 2-2.3F 12 - 2.3 6.97 x 1.38 x 2.40 2.64 2.0 WKAl2-26NB 12 - 26 6.50 x 6.93 x 4.92 4.92 20.3 WKAl2-3.3F 12 - 3.2 5.28 x 2.64 x 2.40 2.64 3.2 WKAl2-33C 12 - 35 772 x 5.16x 6.10 6.57 25.4 WKAl2-5.1A 12 - 4.5 5.51 x1.89 x3.98 4.21 4.4 WKAl2-33J 12 - 35 7.72x5.16 x6.10 709 25.4 WKAl2-5F 12 - 5 3.54 x 2.76 x 3.98 4.21 4.0 WKAl2-44C/FR 12 Y 45 7.80 x 6.54 x 6.85 6.85 35.7 WKA1 2-7.5F 12 - 75 5.94 x256 x374 3.98 6 0 WKAl2-55C/FR 12 Y 60 902x 543x 8.19 835 10 3 Continued on Next Page For more information please contact: Re IacementUF2 os©eye www.ReplacementUPSbattery.com Phone: 952-217-6611 • Email: info @replacementupsbattery.com Continued from Previous Page Page 2 SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Reese Capacity Dimensions Height Over Weight • Item• Volb Retardant Al L x W x H(in.) Terminal(ln.) (lbs.) Maw it Vohs Retardant Al L x W x H(In.I Terminal(in.) (lbs.) WKAl2-55P/FR 12 Y 60 9.02 x 5.43 x 8.19 9.06 40.3 WKA6-14A 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 WKAl2.80C/FR 12 Y 80 10.24 x 6.65 x 8.31 8.46 55.1 WKAS-14T1 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 WKAl2-80J/FR 12 Y 80 10.24 x 6.65 x 8.31 9.06 55.1 WKA6-14T2 6 - 14 4.25 x 2.80 x 5.51 5.51 62 WKAl2-100C/FR 12 Y 100 12.09 x 6.65 x 8.31 8.46 72.8 WKA6-14T3 6 - 14 4.25 x 280 x 5.51 5.51 6.2 WKAl2-100J/FR 12 Y 100 12.09 x 6.65 it 8.31 9.06 72.8 WKA6-42F2 6 - 42 6.38 x 3.46 x 6.42 6.69 15.9 WKAl2-125C/FR 12 Y 140 13.43 x 6.81 x 11.06 11.3 104.7 WKA6-42N8 6 - 42 6.38 x 3.46 x 6.42 6.85 15.9 WKA6-1.3F 6 - 1.3 3.82 x 0.94 x 2.05 2.28 0.7 WKA4-4.5F2 4 - 4.5 1.85 x 1.85 x 3.98 4.21 1.3 WKA6-3.3F 6 - 3.2 5.28 x 1.34 x 2.40 2.64 1.6 WKA6-5F 6 - 5 2.76 x 1.85 x 3.98 4.21 2.1 WERKER SLA CHARGERS WKA6-5SP 6 - 5 2.64 x 264 x 3.82 4.53 2.0 Disunion Weight WKA6-7.2F 6 - 7.2 5.94 x 1.34 x 3.74 3.98 3.0 hem* Volts art L x W x H(ins.) (lbs.) WKA6-8.2F 6 - 8.2 3.90 x 2.24 x 4.53 4.53 3.8 WK6V500 6V 500mA 2.36 x 2.04 x.73 0.58 WKA6.10F 6 - 10 5.94 x 1.97 x 3.74 3.98 4.4 WK12V500 12V 500mA 2.36 x 2.04 x.73 0.66 WKA6-12F 6 - 12 5.94 x 1.97 x 3.74 3.98 4.6 WK6V1000 6V 1000mA 2.54 x 2.32 x 1.95 0.86 WKA6-12F2 6 - 12 5.94 x 1.97 x 3.74 3.98 4.6 WK12V1000 12V 1000mA 2.54 x 2.32 x 1.95 1.00 • v V •