Report -PS2019-- 0013a, 103-06 51'v RECEIVED •'•' '�'� A"" 6 2014 . . •, .•" W YAT . rvoF WARD ,If•�s ♦v M A�1 F.♦ hZ � -�- -�- -� FIRE PROTECTION , I 111 I)111N�;DIVISIDP 9095 S.W. Burnham Tigard, OR 97223 DXL 10206 SW WASHINGTON SQUARE ROAD TIGARD, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL tL,C1I 'J Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers . Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described `4."- Ti - Description herein must be installed and maintained -_— in compliance with this document, as - The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa Sprinklers described in this data sheet any I p lion,in addition to the standards of an `P° I are standard response,standard cover- other authorities having jurisdiction. 1111-1! , . age,decorative 5 mm glass bulb type Failure to do so may impair the perfor- a: : spray sprinklers designed for use in mance of these devices. 7- -y- light, ordinary, or extra hazard, corn- mercial occupancies such as banks, The owner is responsible for maintain- __ hotels, shopping malls, factories, ing their fire protection system and refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with .- TY-B Pendent Sprinkler, where appli- any questions. cable,is intended for use in areas with a finished ceiling.This recessed pendent Sprinkler sprinkler uses one of the following: p 4 r--� �s • A two-piece Style 15 Recessed Identification °X µ . Escutcheon with recessed adjust- �■ g' ment up to 5/8 inch (15,9 mm)from Numbers (SINs) . the flush pendent position. - • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT / Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT - .. ment up to 1/2 inch (12,7 mm)from Technical `' - the flush pendent position. ■echnical The adjustment provided by the Temperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM,LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Finishes Resistant Sprinklers. Sprinkler:Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)' 'The maximum working pressure of 250 psi Physical Characteristics • (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sealing Assembly Stainless Sheet TFP700 for the `INSTALLER Discharge Coefficient Steel w/TEFLON WARNING" that provides cau K=5.6 GPM/psi1/2(80,6 LPM/bar1/2) Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- - nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 • 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* _�....., — 1-- 5 •�I 7/16' —= (11,1 mm) �= IMF M- . 4 NOMINAL 2° 0 1 ' MAKE-IN in (50,8 mm) - 2 �I 2" 1-3/8" 3 4 i (50,8 mm) (34,9 mm) TAII, WRENCH 1 I I FLATS f 1/2"NPT** DEFLECTOR* I— 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE �, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. • 1 glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of . SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubbler the 135°F (57°C)) to inch (1,6 mm)for the 135 F (57 C) to 3/32 Upright(TY315)and Pendent(TY325) inch (2,4 mm) for the 360°F (182°C) ��yr Sprinklers are intended for fire protec- temperature ratings. i tion systems designed in accordance with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 OP-1 is based on the requirements of NFPA ft:lbs. (9,5 to 19,0 Nm). Higher levels �.. 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the Lion Data Sheets). Only the Style 15 sprinkler. IN TO ENSURE or Style 20 Recessed Escutcheon,as Do not attempt to compensate for ENGAGEMENT applicable, is to be used for recessed insufficient adjustment in to escutch- WITH SPRINKLER pendent installations. eon plate by under-or over-tightening WRENCHING AREA P Y 9 g FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent • Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3.Tighten the sprinkler into the sprinkler fitting using only the W-Type 2-7/8"DIA. • 6 Sprinkler Wrench (Figure 2). With (73,0 mm) reference to Figure 1,apply the W-Type 2-1/4"DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) — Torque sprinklers 7 to 14 ft:lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i \ _ - FLUSH The Series TY-B Recessed Pendent 3/8±5/16" i 1 I I Sprinklers must be installed in actor- (9,5±7,9 mm) '� dance with the following instructions. t I �� Step A.After installing the Style 15 or t-' 1/8" ] I Style 20 Mounting Plate,as applicable, MOUNTING - y g pp SURFACE (3,2 mm) over the sprinkler threads and with -- ----— I pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into TY-B PLATE the sprinkler fitting. 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) sprinkler fitting 7 Recessed Wrench (-Type WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 Sprinkler 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER 2-1/4"DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" 1/2" 12,7 mm)TY-B Sprinkler and push the (7,9±6,4 mm) ( ) Closure over the Mounting Plate until 1 No FLUSH its flange contacts the ceiling. 7,, 1 1 . ,. i Care and t 1 — 1/8"Maintenance SOURFAC - (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, _�_ __ I Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav- ing to the sprinklers -before, during, ing jurisdiction. Contact the installing owner must assure that the contractor or sprinkler manufacturer sprinklers are not used for hanging and after installation.Sprinklers dam- p g g aged by dropping, striking, wrench regarding any questions. any objects and that the sprinklers are twist/slippage, or the like, must be Automatic sprinklers are recommended only cleaned by means of gently dust- replaced. Also, replace any sprinkler to be inspected,tested,and maintained ing with a feather duster; otherwise, that has a cracked bulb or that has lost by a qualified Inspection Service in non operation in the event of a fire or liquid from its bulb. (Ref. Installation accordance with local requirements inadvertent operation may result. Section.) and/or national codes. - Sprinklers which are found to be leak Thereafter, annual inspections per ing or exhibiting visible signs of corro- sion must be replaced. NFPA 25 are required;however,instead of inspecting from the floor level, a . Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page4of4 P/N* 77 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2-NPT) TY325 3 PURE WHITE(RAL9010)" 155 155°F(68°C) POLYESTER Use suffix"i'for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-I 4 POLYESTER 175 175°F(79°C) 9 CHROME PLATED 200 200°F(93°C) Eastern Hemisphere sales only PB6 286°F(141°C) 360 360°F(182°C) 000 OPEN'*' "'OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish,P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify")finish,P/N(specify*) •Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. NCO TEFLON Is trademark of The DuPont Corporation. Fire Protection Products • tiio Worldwide Contacts www.tyco-fire.com Series RFII — 5.6 K-factor "Royal Flush iI" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General stallation or finish. The tip of the Pro- tective Cap can be used to mark the :.. Description center of the ceiling hole into plaster M board or ceiling tiles by gently push- The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- �"� .I "Royal Flush II" Concealed Pendent tective Cap. When ceiling installation ir- Sprinklers Quick Response (3-mm is complete, the Protective Cap is re- bulb) and Standard Response (5-mm moved and the Cover Plate/Retainer . bulb), are decorative sprinklers featur- Assembly is installed. „` ing a flat cover plate designed to con- As an option,the Series RFII Standard ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal. TY3531 (3-mm Bulb) is UL Listed, ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust C-UL Listed, VdS Approved Listed, Each sprinkler includes a Cover Plate/ Seal is intended for sensitive areas icate No. G4090007), and NYC Ap- Retainer Assembly and a Sprinkler/ where it is desirable to prevent air and proved (MEA 353-01-E as Quick Support Cu Assembly. The separa- dust from the area above the ceiling to p ( ) pp Cup y p pass through the cover plate. Response. ble, two-piece assembly design pro- p g p vides the following benefits: • TY3531 (3-mm Bulb) is FM and NOTICE LPCB Approved (Ref. No. 094a/10) • Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response. and pressure testing of the fire pro- Sprinklers described herein must be Factory Mutual and LPCB do not tection system prior to installation installed and maintained in compli- approve any concealed sprinklers of a suspended ceiling or applica- ance with this document and with the for quick response. tion of the finish coating to a fixed applicable standards of the National ceiling. pp TY3551 (5-mm Bulb) is UL Listed, Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and ceiling panels for access to building ties having jurisdiction.Failure to do so NYC Approved (MEA 353-01-E) as service equipment without having may impair the performance of these Standard Response. to first shut down the fire protection devices. system and remove sprinklers. Approvals for Air and Dust Seal The owner is responsible for maintain- UL and C-UL Listed for use with the • Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de- RFII Standard Response Concealed vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard lord R. sure of flexibility in determining the The installing contractor or sprinkler length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure sprinkler drops. with any questions. The Series RFII Sprinklers are shipped Maximum 250 psi (17,3 bar) by UL, C-UL,and NYC with a Disposable Protective Cap.The Sprinkler Maximum 175 psi (12,1 bar Protective Cap is temporarily removed p ( bar) by FM, during installation and replaced to help Identification VdS,and LPCB protect the sprinkler during ceiling in- Temperature Rating Number (SIN) 155°F(68°C)Sprinkler with IMPORTANT TY3531 — 3 mm bulb 139°F(59°C)Plate Always refer to Technical Data Sheet TFP700 for the `INSTALLER TY3551 — 5 mm bulb 200°F(93°C)Sprinkler with WARNING" that provides cautions 165°F(74°C)Plate with respect to handling and instal- Technical Discharge Coefficient lation of sprinkler systems and com- ponents. Improper handling and in- Data - stallation can permanently damage Adjustment a sprinkler system or its components Sprinkler Approvals 1/2 inch(12,7 mm) and cause the sprinkler to fail to Approvals apply only to the service • operate in a fire situation or cause it conditions indicated in the Design Cri- to Finishes operate prematurely. teria section. See the Ordering Procedure section. Page 1 of 4 MARCH 2013 TFP181 TFP181 Page 2 of 4 Physical Characteristics 1/2°NPT J / SEALING • , Frame Bronze , ASSEMBLY Support Cup Chrome Plated Steel 1 ,■, Guide Pins Stainless Steel FRAME Jai L� 0,..........................Deflector Bronze , - CAP •Compression Screw Brass , t 4 Bulb Glass ;ii -- Cap Bronze or Copper 1 $ Sealing Assembly Beryllium SUPPORT . Nickel w/TEFLON CUP WITH I BULB Cover Plate Brass ROLL FORMED Retainer Brass THREADS Ejection Spring Stainless Steel — 7 COMPRESSION Design ( SCREW GUIDE � i Criteria PINS(2) ' I roar z 1/The TYCO Series RFII 5.6 K-factor, ,_ __ DEFLECTOR "Royal Flush II" Concealed Pendent (DROPPED Sprinklers are intended for fire protec- DEFLECTOR L ,,_ POSITION) tion systems designed in accordance -s -r with the standard installation rules rec- ognized by the applicable Listing or SPRINKLER/SUPPORT CUP Approval agency;for example,UL List- ASSEMBLY ing is based on NFPA 13 and VdS Ap- I I proval is based on the CEA 4001. THREAD INTO ) I RETAINER For more information on LPCB and SUPPORT 0 i WITH THREAD CUP UNTIL Q DIMPLES VdS Approvals,contact Tyco Fire Pro- MOUNTING tection Products at the following office: SURFACE IS EJECTION Enschede, Netherlands FLUSH WITH SPRING Telephone:31-53-428-4444 CEILING Fax:31-53-428-3377 The Series RFII Concealed Pendent J ' Sprinklers are only listed and approved rr with the Series RFII Concealed Cover / Plates having a factory applied finish. SOLDER / COVER TABS(3) COVER PLATE/RETAINER PLATE NOTICE ASSEMBLY Do not use the Series RFII in applica- FIGURE 1 Lions where the air pressure above MODEL RFII CONCEALED SPRINKLER the ceiling is greater than that be- ASSEMBLY low. Down drafts through the Sprin- kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in- sprinkler operation in a fire situation. sufficient adjustment in the Sprinkler The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- Operation "Royal Flush II" Concealed Pendent kler/Support Cup Assembly.Re-adjust Sprinklers must be installed in accor- the position of the sprinkler fitting to When exposed to heat from a fire, the dance with this section. suit. Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the . Retainer at three points, falls away to Do not install any bulb-type sprinkler if pendent position with the center-line expose the Sprinkler/Support Cup y yp p of the sprinkler perpendicular to the Assembly. the bulb is cracked or there is a loss mounting surface. of liquid from the bulb.With the sprin- Step 2.Remove the Protective Cap. - The Deflector — supported by the kler held horizontally, a small air bub- Guide Pins — then drops down to its ble should be present. The diameter Step 3. With pipe thread sealant ap- operational position. of the air bubble is approximately 1/16 plied to the pipe threads, hand-tighten The glass bulb contains a fluid that ex- inch (1,6 mm)for the 155°F(68°C)and the sprinkler into the sprinkler fitting. pands when exposed to heat. When 3/32 inch(2,4 mm)for the 200`F(93°C) Step 4. Wrench-tighten the sprinkler the rated temperature is reached, the temperature ratings. using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as glass bulb,activating the sprinkler and should be obtained by applying a min- shown in Figure 3. allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap ft:lbs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms of torque can distort the sprinkler In- out against the Support Cup. (Refer let with consequent leakage or impair- to Figure 4.)The Protective Cap helps ment of the sprinkler, prevent damage to the Deflector and TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER - DIAMETER 4— HOLE --► FITTING DIMENSION C SPRINKLER 1 J b�t■ SUPPORT CUP ASSEMBLY I I r- 1/2" ' (12,7 mm) 1 THREADED l Al „_" D ADJUSTMENT )I I■I • FACE �� OF CEILING, �� RETAINING RING 1 '""'• �"' MOUNTING /l �� -7-SURFACE // ;� FIGURE 4 -rJ _ DISPOSABLE PROTECTIVE CAP --N\ -------- -. , i Arms during ceiling installation and/or _ I finish.You can also use the Protective I T -`-� Cap to locate the center of the clear- 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE ance hole by gently pushing the ceiling (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY the Protective Cap. COVER PLATE COVER PLATE NOTICE -PROFILE DEPTH DIAMETER - As long as the Protective Cap remains DIMENSION B DIMENSION A in place, the system is considered A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service". Step 6.After the ceiling has been com- B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) pleted with the 2-1/2 inch(63,5 mm)di- ameter clearance hole and in prepa- FIGURE 2 ration for installing the Cover Plate/ SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis- card the Protective Cap.Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the f=i' FRAME �� _.__,'j�l' „ Deflector does not move up and down freely, replace the entire Sprinkler. II ARM 7 I� r■ Do not attempt to modify or repair a - if ,) damaged sprinkler. SUPPORT Step 7. When installing an Air and CUP I i Dust Seal, refer to Figure 5; otherwise, 11 _ i proceed to Step 8. To attach the Air i i and Dust Seal, verify the angle of the ■" i�,�-"�� outside edge of the seal is oriented ac- cording cording to Figure 5. Start the edge of --------- the Retainer in the grooved slot of the 0 7/8"(23 mm) Air and Dust Seal and continue around SQUARE the retainer until the entire Air and Dust Seal is engaged. /��-` Step 8. Screw on the Cover Plate/ ALIGN Retainer Assembly until the Retainer ARROWS WITH ///', I I (shown in Figure 2)or the Air and Dust FRAME ARMS /I t Seal (shown in Figure 5) contacts the rl ceiling. Do not continue to screw on l i 1 the Cover Plate/Retainer Assembly ACCEPTS `�,_r�' so that it lifts a ceiling panel out of its 0 1/2"SOCKET \\ normal position. If you cannot engage DRIVE the Cover Plate/Retainer Assembly FIGURE 3 with the Support Cup or you cannot RFII SPRINKLER WRENCH engage the Cover Plate/Retainer As- . sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Care and SUPPORT SPRINKLER FACE OF _ORIENT • Maintenance CUP _ CEILING BEVEL AS j=t. �� „) The TYCO Series RFII 5.6 K-fac- COVER tor, "Royal Flush II” Concealed Pen- NI. PLATE dent Sprinklers must be maintained , i RETAINER —and serviced in accordance with this )i �, ASSEMBLY section.• Before closing a fire protection system `� -_ ' i / AIR main control valve for maintenance .'■�, )rl �� ��/ AND DUST work on the fire protection system that it controls, obtain permission to shut :— -----• LIP OF COVER SEAL down the affected fire protection sys- RETAINER PLATE tern from the proper authorities and FIGURE 5 notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) ed by this action. Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Ordering Assembly can delay sprinkler opera- reinstall it or a replacement without re- tion in a fire situation. installing the Cover Plate/Retainer As- Procedure When properly installed, there is a sembly. If a Cover Plate/Retainer As- nominal 3/32 inch(2,4 mm)air gap be sembly becomes dislodged during Contact your local distributor for tween the lip of the Cover Plate and the service,replace it immediately. availability. When placing an order, ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the full product name. This air gap is necessary for proper their ire testing, and maintenance of Sprinkler/Support Cup Assembly operation of the sprinkler. If the cell- their fire protection system and devic- op requires a ion of the sprinkler. after If sprinkler es in compliance with this document, Specify: Series RFII (specify SIN), installation, ensure that the new paint as well as with the applicable stan- K=5.6, "Royal Flush II" Pendent Sprin- installation, not n, ensure off any that the air gap. dards of the National Fire Protection klers (specify) temperature rating and Association(e.g.,NFPA 25),in addition (specify)finish, P/N(specify). Do not pull the Cover Plate relative to to the standards of any other authori- the Enclosure.Separation may result. ties having jurisdiction.Contact the in- 155°F(68°C). 200°F 193°CI stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200 • Sprinklers which are found to be leak- TY3551 regarding any questions. 51-790-1-155 51-790-1-200 ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/ Automatic sprinklers must never be inspected,tested,and maintained by a Retainer Assembly: P qualified Inspection Service in accor- painted, plated, coated, or other- dance with local requirements and/or Specify: (temperature rating from be- wise altered after leaving the factory. national code. low) Series RFII Concealed Cover Modified sprinklers must be replaced. Plate with(finish),P/N(specify). Sprinklers that have been exposed to 139°F(59°C)(a) 165°F(74°C)(b) corrosive products of combustion,but Grey White have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165 if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165 by wiping the sprinkler with a cloth or Pure White(c) by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165 Signal White Care must be exercised to avoid dam- (RAL9003) 56-792-4-135 56-792-4-165 age to the sprinklers - before, during, Jet Black and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165 aged by dropping, striking, wrench Brushed twist/slippage, or the like, must be re- Chrome 56-792-8-135 56-792-8-165 placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165 has a cracked bulb or that has lost Custom 56-792-X-135 56-792-X-165 liquid from its bulb. (Ref. Installation (a) For use with 155°F(68°C)sprinklers. Section.) (b) For use with 200°F(93°C)sprinklers. Exercise care to avoid damage to (c) Eastern Hemisphere sales only. sprinklers before, during, and after in- Sprinkler Wrench stallation.Replace sprinklers damaged Specify:RFII Sprinkler Wrench, by dropping, striking, wrench twisting, P/N 56-000-1-075. wrench slipping, or the like. Also, re- place any sprinkler that has a cracked Air and Dust Seal • bulb or that has lost liquid from its Specify:Air and Dust Seal, bulb.(Refer to the Installation section.) P/N 56-908-1-001. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 j Telephone+1-215-362-0700 Copyright m 2013 Tyco Fire Products,LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Dyna-Thread® - M-COAT® Submittal Data Sheet o Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread'---M-Coat' sprinkler pipe represents an engineering NPs Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR • advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft;kglm Lbs/Ft kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — - 11/4" 1.408 1.870 2.54 9.50 1.00 O Comparison to Schedule 40 32 35.8 2.8 3.78 — — 11/2" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread='-M-Coat"'inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — - giving it superior hydraulics.Also,when used in combination with Dyna- 2- 2.104 3.050 4.57 8.41 1.00 Flow-M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — - approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread-M-Coat and Sch-40 are equal based on the calculated wall 0 c 0 40)10. thicknesses per UL.The consistent quality of steel used to make Dyna-Thread- .,,,,,E, M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread-M-Coat is protected by a clean,durable mill coating for OO American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available • and lighter weight, Dyna-Thread-M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed O Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread- M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread-M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread-M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread-M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread-M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread- use in wet systems.Dyna Thread-M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.0.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread-M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread-M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 9Iallied Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&/CONDUIT• Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 "'""`°`- 02013 Atkore International,Inc.All Rights Reserved.STP-53-4M-1301 Ductile Iron Threaded Fittings • • N�- •_ • • • 71� { 1 n. ;44 . . ' 44401038,I I I; C - r�.( )AI.)1 I4� „ . . � • ,F.xwatxfib4L AA'• �i�{ir� S+r� �' 11vb�7 N\ •• MYLndl .h.+w' A+WArAS fi' t1f '. .rii .n. > 1^P6!1 .•fFY^..,y' r c'Y+s. {.y. u.4 fi + V. - Y Ductile Iron Threaded Fittings feelf 'at1O11S • © branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 c U` us LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 411> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fillings -20 to 100 500 15cS 500 200 480 256 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Ci. Ductile Iron Fittings-Class 300 UL/FM • Lr I'M Cla us APPROVED • Fig. 35E 3-90°Elbow LISTED A Size A Packing _ Weight ��� Part Number o�� in in Inner Master lb 111 ___}�i_ 1/2 35E 3004 1.13 100 200 0.2 1 �� 3/4 35E 3006 1.31 70 140 0.3 jA 1 35E 3010 1.50 40 80 0.5 "% ; 1 1-1/4 35E 3012 1.75 25 50 0.8 ' 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 • Fig. 35RE3-90°Reducing Elbow (-B , Size Part Number A B Packing Weight d,.... in in in Inner Master lb ti.� 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 s•. 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 A.• i 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 ,0,5..,-.. 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 351;1E3012010 1.58 1.67 30 60 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 _ 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 - 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 -- 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 _' 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 U 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 U .;•.1L2:x 1;1/2., ,_35RE3024014 2.16 2.51 6 ;;,412 2.2 0 2-1/2 x 2 . 35RE3024020 2.39 2.60 6 12 2.5 I i Fig. 35F 3-45°Elbow ESize Part Number A Packing Weight ' A in in Inner Master lb / �, 1/2 35F 3004 0.88 150 300 0.2 *•' 3/4 35F 3006 0.98 80 160 0.3 '. 1 35F 3010 1.13 40 80 0.5 ,• 1-1/ 4 35F 3012 1.29 25 50 0.7 Af IA 1-1/2 35F 3014 1.44 20 40 1.0 W - • 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee • Size A Packing Weight Part Number in in Inner Master lb "` �_` A 1/2 35T 3004 1.13 80 160 0.3 I�111 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 �..` 1-1/4 35T 3012 1.75 10 20 1.1 • A A 1-1/2 351 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL!' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com i Ductile Iron Fittings- Class 300 UL/FM • QUALITY?WS C ® US • Fig. 35RT3-Reducing Tee LISTED CEO • 1111111 Size A B C Packing Weight �;p Part Number in in in in Inner Master lb � h►� C 3/4 x 1/2 35813006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 �_-- -- li 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 r-����=" 1 x 3/4 35R13010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 314 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A 1x 3/4 x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-114 x 1 x 1/2 35RT3012010004 ,1.34_ .1,.26 1.53 25 50 0.7 1-114 x 1 x 34 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x 1 x 1 35RT3012010010 5 '9'�5O 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x 1/2x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 314 35RT3014006 1.52 1.52 1.75 16 32 1.1 -1-172x 314 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1'2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 • 1-1/2x 1 x 1-1/4 35RT3014610012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 D 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 1).9 U 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 C 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 T 1-1/2 x 1-1/4 x 1-1/4 359T3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 L 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 E 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.0 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 _ 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 . 2 x 1-112 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size Part Number A B C Packing Weight in in in in Inner Master lb . I C 3/4/ ,.N x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 ' , 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 ,"___-_1---�� 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A B 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX .323)890-4456 • www.smithcooper.com 112 �` 1 1 ucti e ron ><ttings- ass 1 I / . (_Quay.! jws_ c ® us APPROVED • A Fig. 35CP3 -Straight Coupling with Ribs LISTED -•�• Size A Packing Weight �` Part Number in in Inner Master lb 111111-- 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size A Packing Weight =i - in Part Number in Inner Master lb / A 1 x 1/2 35RC3010004 1.69 80 160 0.3 • 1 x 3/4 35RC3010006 1.69 60 120 0.4 e_1!, 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1(not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Pan Number A Packing Weight B in in Inner Master Ib 1 x 12 35HB3010004 1.06 180 360 0.2 V I .IA 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1!2 5HB3014010 1.25 75 _; .0.4 1-1!2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 U 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 C 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 T 1 Fig. 35SP3 -Square Head Plug ESize Part Number A Packing Weight in in Inner Master lb • _ ��`���, A 3/4 35SP3006 0.12 350 1700) 0.1 l` �; 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3-Union with Brass Seat A Size Part Number A Packing Weight �� in in Inner Master lb " ` ' ��� y����� 1 35U 3010 2.19 20 40 1.0 ttii 1-1/4 35U 3012 2.50 15 30 1.2 `0 1-1/2 35U 3014 2.62 10 20 1.7 l ir,., / 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com ! � Ductile Iron Fittings- Class 300 UL/FM • ( warn,,?Lys c 0 us <V. APPROVED Fig. 35X 3-Cross LISTED A A „ Size A Packing Weight 'd�i� in in Inner Master lb t.• i .,,,A- e iPart Number A 1 35X 3010 1.50 20 40 0.9 i___ I 1-1/4 35X 3012 1.75 12 24 1.4 I� ___! =I 1-1/2 35X 3014 1.94 8 16 1.8 •. or., ��� A 2 35X 3020 2.25 6 12 2.8 A ism • B B Fig. 35RX3-Reducing Cross Size Part Number A B Packing Weight ow t��� IA in in in Inner Master lb 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 C JA 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 . Fig. 35C 3-Cap Size A Packing Weight Part Number o f in in Inner Master ib . A 1/2 35C 3004 0.87 300 600 0.1 i 1 i 1 35C 3010 1.16 110 220 0.2 D . 1-1/4 35C 3012 1.28 70 140 0.4 U 1-1/2 35C 3014 1.33 50 100 0.5 C 2 35C 3020 1.45 25 50 0.8 T 2-1/2 35C 3024 1.70 18 36 1.6 L E Fig. 35BC3-Beam Clamp _ y��9 Size Part Number A Packing Weight n in Inner Master lb A �� 3 5 35BC3003 0.75 100 200 0.3 MINIM 1/2 35BC3004 0.75 80 160 0.5 -- a SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(3231 890-4456 • www.smithcooper.com 114 Pipe Hangers • Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO Fig.200F- "Trim line" Adjustable Band Hanger with Felt Lining (B-Line Fig.B3170NFF) c C)us • Fig.200C- "Trim line" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) USTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications v Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. .9l Features: - • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe _ �'.j. ' ' r types and protect CPVC plastic pipe from abrasion.Captured design keeps adjusting nut from separating with hanger. Hanger is easily n B installed around pipe. A For hanger with non-captured nut order Fig.200S. f • (21/2" (65mm)thru 8" (20omm))Spring tension on nut holds it securely in r' s; �\ hanger before installation.Adjusting nut is easily removed. rs Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) Fig.200-1/200.3/a in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fg 200-21/2 to 200-8 Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (2oomm)). Conforms to Federal Specifications 1NW-H-1 71 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, _ Type 10. Maximum Temperature: 650°F(343°C) oaf `5' • Finish: Pre-Galvanized. Stainless Steel _ ?" materials will be supplied with (2)hex nuts (,/,.- - i ,-4 in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. = Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt,/100 -41....-, Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-'/2 I/2" (15) 3/8"-16 3Va' (79.4) 25/8" (66.7) 11 (5.0) ',� 200-3/4 3/4" (20) 3/8%16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1" (25) 3/e"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) ‘ 200-11/4 11/4' (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) t 200-11/2 11/2' (40) 3/8-16 37/0' (98.4) 27/8" (73.0) 14 (6.4) 1 . 200-2 2" (50) 3/8'-16 41/2° (114.3} 3" (76.3) 15 (6.9) f 200-21/2 21/2" (65) 3/8'-16 55/9" (142.9) 41/8' )104.7) 27 (12.3) , ...r 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8' (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/a"-16 73/8" (187.3) 5" (127.0) 35 (16.0) . 200-5 5" (125) 1/2"-13 91/8 (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4' (171.4) 73 (33.4) 200-8 8' (200) 1/2'-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E:T•N Threaded Accessories B3205 -Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) ' B3205L - Threaded Rod (right& left hand threads) / TL Size Range: 3/8"-16 thru 3"-4 rodm 111���1111 Material: Steel / Rod is threaded on both eends with right ht hand threads of the length Also n���1�\\li 9 9 ,:� A available with left and right hand threads-specify Fig.B3205L when ordering. 1' Thread Size Maximum Temperature: 750°F(399°C) • Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number,rod size,length and finish Standard Design Load Thread Size Thread Length TI. 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 63205-7Is x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) ' B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-2112 x'1' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'1' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.loo) Fig.99- All Threaded Rod Cut To Length �,,,- ' Size Range: 3/a"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length Ff41� , Material: Steel 1),C N vd Maximum Temperature: 750°F(399°C) ` �.o Finish: Plain.Contact B-Line for alternative finishes and materials. / v d ' Order By: Part number,rod diameter and finish ~a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/s"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) • ATR 7/s"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised 428/2014 B-Line by EA•N VERTICAL MOUNT SAME`" SAMMYSR' for Wood ii. , . Not less than Wood Flooring 2•nominal width Product Features (1 � •No pre drilling required, Not less than •Quick to install using the Sammy 3•nominal Nut Driver with an 18V cordless th cimeas(2-117) • .depth ors'tle Wood Joist drill;driver. I f vertical^.ember) _ ti�'�, "J� '• f •Saves time from traditional Double Sheetrod methods. For vet cal use- Ceiling install in center of lower face. •Reduces installation cost. Miemum 2'embedment into base �• material torWFPA 13 . „ Composite!Truss •Made in the U.S.A. Consulttmssmanfiacturerfcr recommended installation point. _---- = "Pre-dofeng maybe required for GST .L 25.350.7001 availabre on page f0. II l) Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(lbs) Qty Qty 114' 8002957 GST 100 1/4 x 1' 210 (7116'OSB) 25 125 670 (314"Ply) , 1/4" 8003957 GST 200 114 x 2" 1760 (Fir) 25 125 `- 1/4' 8004957 GST 300 1/4 x 3' 2060(Fir)glialffiffinatiMilt 25 125 3 318" 8006957 GST.75 114 x 3/4" 564 (314"Ply) 25 125 ill 'g' 3/8' 8007957 GST 10 114 x 1' 210 (7116'OSB) 300 25 125 — Q.<;>. 3/8' 8008957 GST 20 114 x 2" 670 (3/4'Ply)1760 (Fir) 850 1475 25 125 T. 3/8' 8068925 GST 20-SS 1/4 x 2" 1760(Fir) 850 W. 25 125 Q. 3/8" 8009925 GST 25-380 3/8 x 2-1/2' 2113 (Fir) 1500 25 125 4-4 318' 8010957 GST 30 114x 3' 2060(Fir) 1500 _1475 25 125 #14 Black Nut Dryer 3/8" 8069925 GST 30-SS 1/4 x 3" 2060(Fir) 25 125 Par,#8113910 2111 3/8' 8011925 GST 40 114 x 4' 2180(Fir) 25 125 3/8" 8012925 GST 60 114 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 114x2" 1760(Fir) i ; 25 125 0 112" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 — 112' 8015925 GST 3 114 x 3" 2275(Fir)` 25 125 112' 8016925 GST 4 114 x 4" 2180(Fir) 25 125 1/2" 8017925 CST 114x6" 2230 ( r} '(Fir) " '" , 25 125 — 014 SW Red xrsr�earsu w u 0 Nut Driver Part 6 8114910 I SAMMY Swivel Head' for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. illX" ... . __i_ •Accommodates up to 3''/z'x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. ' 0 _:,. .x� ' I. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout Otis) Load(Ibs) Load(Ibs) Thickness Qty Qty 4i•C• 3/8' 8139957 SH-GST 20 114x2' 1257(Fir) 1050 1475 25 125 125 Q^< 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 4 F�oliS V r wus. ;,/ / -