Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MECHANICAL PERMIT 8 COMMUNITY DEVELOPMENT Permit#: MEC2015-00230 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/21/2015 Parcel: 2S112DA01000 Jurisdiction: Tigard Site address: 6610 SW CARDINAL LN Project: Umpqua Bank Subdivision: 1995-098 PARTITION PLAT Lot: 1 Project Description: Remove and replace(3)gas pack units,installing new structural support frames. Contractor: OREGON AIRE INC Owner: PACIFIC REALTY ASSOCIATES 7715 NE 33RD DR STE A ATTN: N PIVEN PORTLAND, OR 97211 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-335-2222 PHONE: 503-624-6300 FAX: 360-423-1978 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 05/21/2015 $4,886.31 Class of Work: ALT Type of Const: VB Plan Review 05/21/2015 $1,221.58 Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 05/21/2015 $586.36 Stories: Info Process/Archiving-Lg$2.00(over 05/21/2015 $2.00 11x17) Project Valuation: $178,000.00 Info Process/Archiving-Sm$0.50(up to 05/21/2015 $20.00 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $6,716.25 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: 1 Structural Welding Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: 3 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a c•py of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332. • Issued By: Q -ermi = i.nature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit ApplicaaFCEIVED FOR OFFICE USE ONLY City of Tigard Received Date/By: �3 l / Permit No.:ff e 9 ,j5 )91 13125 SW Hall Blvd.,Tigard,OR 97223 APR 2 3 2015 A... ..../0 w O� • Plan Review ' . Phone: 503.718.2439 Fax: 503.598.1960 Date/By: s/v�/ 4$ (or Other Permit: I I c r n Inspection Line: 503.639.4175 CITY OF TIGARD Date ReadyBy: {/ luris• See page 2 for Internet: www.tigard-or.gov BUILDING DIVISION Not Readethoo.di Ls .CL/t7 Supplemental Information s - E OF WORK Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑ Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$$178,000.00 CATEGORY OF CO STRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use check list. ❑ Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total tJOB SITE INFORMATION AND LOCAT I N Heating/cooling: Air conditioning 46.75 Job site address:6610 SW Cardinal Lane Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard Oregon 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: I Project name:Umpqua Bank Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: I Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas HVAC upgrades,Remove and replace(3)rooftop Gaspack AC units including new fireplace 23.32 Structural support frames. Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 0 PROPERTY OWNER , ❑ TENANT Other: 23.32 --- -. Environmental exhaust and ventilation: Name: Umpqua holding Corp. Range hood/other kitchen equipment 33.39 Address:12550 SE 93rd Suite 100 Clothes dryer exhaust 33.39 City/State/ZIP:Clackamas Oregon 97015 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)349-7523 Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT ❑ CONTACT PERSON Other: _ 23.32 Fuel piping: Business name:Steve Larson $14.15 for first four;$4.03 for each additional Contact name:Oregon Aire Inc. Furnace,etc. Address:7715 NE 33rd Drive Suite A Gas heat pump Wall/suspended/unit heater City/State/ZIP:Portland Oregon 97211 Water heater Phone:(503)989-6421 I Fax::(503)3354977 Fireplace Range E-mail:Slarson @oregon-aire.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:Same Other: MECHANICAL PE Address: Subtotal City/State/ZIP: Minimum permit fee($90.00) Phone:( ) Fax:( ) Plan review(25%of permit fee) State surcharge(12%of permit fee) CCB lic.:64235 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature • Fee methodology set by Tri-County Building Industry Service Board Print name:Steve Larson Date:04-23-15 I:\Building\Permits\MEC_PermitApp_040113.doe 440-4617T(11/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Family Fee Schedule: Total Valuation• ` I'ermt Fee: " $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 rIW- - FOR OFFICE USE ONLY-SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT III _ Transmittal Letter , I( ,\F. i) 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: ( _ ___,,i1--A,■ , DAT E ff> D DEPT: BUILDING DIVISION i-{t APR 3 0 2015 � CITY OF TIGARD FROM: �� _ 4 ��� � BUILDING DIVISION COMPANY: iiii �� _ .4 PHONE: — i � 613- Y' RE: C0 LP( L� ��l vr, C C�l ()A (Site Address 0- (Permit Number) LL_A ry 0 f Q'E' er (Project n e i r s bdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: I Description: I Copies: ' Description: Additional set(s)of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(e. •lain : REMARKS: 1g , , e.-(C c ' i p & (�. AL, FOR FFIcE USE ONLY Routed to Permit Technician: Date: -7(2( (,---5" `�• Initials: 1 Fees Due: ❑ Yes ©< Fee Description: Amount I ue: $ Special Instructions: Reprint Permit(per PE): El Yes ❑No El Done Applicant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 6610 SW CARDINAL LN, TIGARD, OR, 97224 Commercial - Mechanical 699 Mechanical final FAIL MEC2015-00230 George Heimos 1. Provide smoke detector shutdown test for air distribution system. 606.4 2. Recall inspection when ready. service@oregon-aire.com Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 6610 SW CARDINAL LN, TIGARD, OR, 97224 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2015-00230 George Heimos Alarm company activated both smoke dampers, test ok Violation Summary: Inspector Contractor