Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT S • COMMUNITY DEVELOPMENT Permit#: FPS2015-00083 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 05/13/2015 Parcel: 2S101BCO2401 Jurisdiction: Tigard Site address: 12650 SW HALL BLVD Project: Snyder Roofing Subdivision: TIGARDIA TERRACE Lot: 3 Project Description: Fire sprinklers-Add(2)new heads for new suspended ceiling. Contractor: SOUND FIRE PROTECTION INC Owner: JFK PROPERTIES OREGON LLC 10756 SE HWY 212 12650 SW HALL BLVD CLACKAMAS, OR 97015 TIGARD, OR 97223 PHONE: 503-655-3775 PHONE: FAX: 503-655-2990 FEES Description Date Amount Specifics: Permit Fee-COM 05/13/2015 $53.78 12%State Surcharge-Building 05/13/2015 $6.45 Type of Use: COM Plan Review-Fire Life Safety-COM 05/13/2015 $21.51 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 05/13/2015 $1.00 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $82.74 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $550.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or dir ues io to_OU • • calling 503.232.1987 or 1.800.332.2344. I sued By: ,t Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System City of Tigard NOISIAIO owing Received 2 Permit No.: " 13125 SW Hall Blvd.,Tigard,OR 9� dJIl dO Jl1.IO Date/By: r �3 a26l4` $3 2 . Plan Review Phone: 503.718.2439 Fax: 503.598.1Qb0.� T A�tw Date/By: Other Permit: TIGARD Inspection Line: 503.639.4175 `�4UU ` Date Ready/By: tuns: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method Supplemental Informati 03,< 0 3 3 TYPE OF WORK REQUIRED DATA:I-AND 2-FAMILY DW LING ❑ N. ••construction Permit fees*are based on the value of the wor. performed. ❑Demolition p Indicate the value(rounded to the nearest do ar)of all Addition/alteration/replacement El Other: equipment,materials,labor,overhead,ant e profit for the CATEGORY OF CONS 1CT1ON work indicated on this application. ❑ 1-and 2-family dwelling Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: El Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors. Job site address: 1'2„, -' au irk AA,l 3 t OD New dwelling area: square feet City/State/ZIP: —7-1" G r""'-t ! 40Re 9-72•2-3 Garage/carport. ea: square feet Suite/bldg./apt.no.: - "� Project name:C i t yelef2 /2 (3i 7) Covered poi-, area: square feet Cross street/directions to job site: Deck ar• . square feet Othe tructure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work pertormed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. PkiND 2 her w. k..\€✓t S ED-r' (/UQ._00 Valuation: $ 6p 4) SL I' ec p e,,L a ct CL . ;,tvG ('rvrv•- C YCa`S hi()G] Existing building area: square feet 2'�t 0 J C New building area: square feet PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fa..:( ) New: APPLICANT ❑ CONTACT PERSON NOTICE Business name: sc v,,.cA F-Ltc- pia a-G.(- (-0'I All contractors and subcontractors are required to he Contact name: ,E ,(•V• c���L licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: l0"Sfo E& 41A 21'� jurisdiction in which work is being performed.If the City/State/ZIP: at* - � Oa Q7ol 5— applicant is exempt from licensing,the following reasons apply: Phone:( ' 'I655--3-7-75 r Fax::($b3) 6,5-5--- 2 G E-mail: \C-N�iL SD Fire. `rte , C-Ort-"N CONTRACTOR BUILDING PERMIT FEES* Business name: (Please refer to fee schedule) Permit fee: Address: City/State/ZIP: State surcharge(12%of permit fee): FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application.) CCB lie.: 7a 3 1(116 Total permit fees: Authorized signature: Amount received: #ga •74/M ,/ �` ` This permit application expires if a permit is not obtained Print name: I r a 6 M.e406-11.._ Date: 5/� i within 180 days after it has been accepted as complete. ((( * Fee methodology set by Tri-County Building Industry Service Board. I\Building\Permits\FPS-PermitApp.dot Rev 01/05/2012 440-4613T(11/O2ICOM/WEB) City of Tigard Permit No.: A c96/s—ADOg 13125 SW Hall Blvd.,Tigard,OR 97223 ET114 Phone: 503.718.2439 Fax: 503.598.1960 Date Received: 5f/3//s Inspection Line: 503.639.4175 TIGARD Internet: www.tigard-or.gov By: FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: SNYDER ROOFING - NEW CEILING Occupancy: OFFICE Job Address: 12650 SW HALL BVLD Type of Construction: Suite: Contractor: SOUND FIRE PROTECTION Phone: 503-655-3775 Number of Proposed or Altered Heads: 2 Type: TY FRB 5.6K SSP Ha,ard: LIGHT HAZARD Density: .10/1500 I, SOUNDFIRE PROTECTION Oregon Construction Contractors Board No. 70003 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams,partitions,walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition,I understand the following is required: • Submit(3)copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: Date: e_7 /"� /�— Print Name: 41 �E /7/e/14/ L I 1:\Building\Fonns\FiresprinklcrAffidavit_071514.docx Page 1 of 1 Sound Fire Protection, Inc. Letter of Transmittal 10756 S.E. HWY 212 Clackamas, OR 97015 Date: Job#: Fax#(503)655-2990 5-7-15 2840-15 Phone#(503 655-3775 Attention: OVER THE COUNTER AFFIDAVIT To: Re: SNYDER ROOFING—NEW OFFICE CITY OF TIGARD • Drawings r Plans r Copy of Letter r Change Order I— Attached I— Other Copies Date Number Description 3 PLANS 3 SPRINKLER HEADS 1 BLD PERMIT APPLICATION 1 AFFIDAVIT PERMIT APPLICATION These are Transmitted as Checked Remarks: ✓ For Approval ✓ For Your Use r° As Requested ✓ Returned for Corrections ✓ For Review and Comment ✓ Prints Returned After Loan to Us 1- Other Sincerely, CCB#70003 Metro#3483 Mike McNeil WA#SOUNDFP0055QL E-MAIL: mcneil @soundfirepro.com t qca Worldwide www.tyco-fire.com Fire Protection Contacts Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers - _z Description described herein must be installed and maintained in compliance with this doc- - The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable a °L" _... Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- �' ! Sprinklers described in this data sheet tion Association,in addition to the stan- ` "'" � ' 1 are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair sprinklers designed for use in light or the performance of these devices. ° ordinary hazard,commercial occupan- cies such as banks, hotels,and shop- The owner is responsible for maintain- ; - in ping malls. g their fire protection system and devices in proper operating conditio- The recessed version of the Series TY- The installing contractor or sprin FRB Pendent Sprinkler,where applica- manufacturer should be contacted. h ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: S rinkler _ • A two-piece Style 15 Recessed p ;' Escutcheon with recessed adjust- Identification . ment up to 5/8 inch (15,9 mm)from the flush pendent position. Number (SIN) - ,,,, • A two-piece Style 20 Recessed � ,- Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2- PT ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2" 'T the flush pendent position. .' The adjustment provided by the Technical - Recessed Escutcheon reduces the iempuature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Approvals 175°F(79°C) Intermediate level versions of Series 200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)° Button Brass/Copper 'The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the `INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi112(80,6 LPM/barl'2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 7 I - NEW SPRINKLERS SCOPE IN SUSPENDED - CEILING ----- r- -1 r IL •44 s OFFICE+ 8-0 i' IIP NEW SUSPENDED GRID CEILING eLtr_--t----- Qtr !4 I I y KEY PLAN '_` EXISTING UPRIGHT i . N.T.- S- 0 It --- n 0 • .it»! •- IC i /GENERAL NOTES: i— ALL MATERIAL IS NEW 4 UL LISTED. NEW PIPING IS BLACK SC14D 40 IMPORT PIPE. n 1 FITTINGS ARE BLACK CAST IRON. ■ ■PARTIAL REFLECTED CEILING JOB NAME: SCALE 1/25 11-0 A% ROOFINGS G 126)50 SW HALL BLvD T IGARD,OR NORTH DESCRIPTION: TENANT IMPROVMENT- SYSTEM DESIGN DATA: SOUND FIRE DRAW BY: .McNEIL LIGHT HAZARD - .10/1500 F RO T E C T I ON INC I�t FILE: 2840-15 TYCO S PRINKLERS 10156 SE HWY 212 DRAWING # TYPE ORIF TEMP FINISH CANOPY SYM QUAN CLACKAMAS, OR 91015 -TY-FRB I� " 155' CHROME CHROME N 2 VOICE (503) 655-3-115 � FAX (503) 655 2990 OR GCB • 10003 1 OF 1 TOTAL THIS SHEET 2 WA REGISTRATION a SOUNDFPO55QL I