Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
RECEIVED MAY 4 2015 carrier CITY OF TIGARD BUILDING DIVISION SUBMITTAL Project Tigard Christian March 11 , 2015 Airefco, Inc. 18755 SW Teton Tualatin, OR 97062 503-692-3210 Table Of Contents Project:Tigard Christian 03/11/2015 Prepared By: 11:47AN 7.5T 3 Unit Report 4 Certified Drawing 5 Performance Summary 8 Unit Feature Sheet 11 10T 12 Unit Report 13 Certified Drawing 14 Performance Summary 17 Unit Feature Sheet 20 Packaged Rooftop Builder 1.39p Page 2 of 20 7.5T Project:Tigard Christian 03/11/2015 Prepared By: 11:47AM 7.5T Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.39p Page 3 of 20 Unit Report For 7.5T Project:Tigard Christian 03/11/201E. Prepared By: 11:47AN Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model- 48TCDDO8A2A5-0A0G0 Unit Length. 7'4.125" Unit Size' 08(7.5 Tons) Unit Width. 4'11.5" Volts-Phase-Hertz. 208-3-60 Unit Height: 3'5.25" Heating Type. Gas ••• Total Operating Weight: 870 lb Duct Cfg:...Horizontal Supply/Horizontal Return Low Heat "' Weights and Dimensions are approximate. Weight Round Tube Plate Fin Coils does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 16 x 20 x 2 Unit Configuration Medium Static Option Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) • 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDDO8A2A5-0A0G0 Rooftop Unit 1 Base Unit Medium Static Option None 2 Speed Fan Controller (VFD) Packaged Rooftop Builder 1.39p Page 4 of 20 • Certified Drawing for 7.5T . • Project:Tigard Christian 03/11/201: Prepared By: 11:47AN NOTES: - - OUTDOOR UCHO OG ES 10¢w N wN¢u FMw w N M Q S wI[I 1 u TNw NNw aI nn1 rt[Nn NWa[N Mr s UNIT K II TYPE J CARRIER tort C01101111011.5 811111(1 COMM.1. DX MENS1 ONE AR INN LLNC15DIMf NSI ONS 41 t// 33 15 7/8 2. CENTER OF GRAVITY 487C-A08 RTPF [10481 [658] 14031 48TC-A09 RTPF [923 /8 3[7916/1 2!77081 CONNECTION SIZES 3.y DIRECTION Of AIR FLOW 49 3/B 37 1/4 15 7/0 A 1 1!0' [35] DIA FIELD POWER SUPPLY HOLE 48TC-012 RTPF PI�--110261 _112511 [916] [1031 1 [10281 B 2 11i'161]DIA POWER SUPPLY KNOCKOUT 11 1/4 33 '15 7/8 IBTC-D08 RTPF C 1 3111 151]DIA GAUGE ACCESS PLUG 110461 [658] 14811 487E-009 RTPF 49 3/8 37 114 15 7/0 ' C 7/6' 1221 DIA FIELD CONTROL WIRING XOLE 11253] 19161 14031 187E-012 RTPF 49 3/8-37 114 15 7/8 ECONOMIZER N000 20-3/4 C 3M'-11 NIT GAS CONNECTION GRAIN•[1257] 1916] 1403] [OPTIONAL/ T tf 2'•14 ITT GAS CONNECTION 11 114 33 2J 3/4'-14 NTT GAS CONNECTION 187E-Doe NCN7 (1018) 1658] [504.21 J G 2' [511 DIA POWER SUPPLE KNOCK-OUT 18TC•D12 MC" /9 3/0 37 111' 19 - .. . •112131 (9161 [n9.4) - _� THRU-THE-BASE CHART (FIELD INST) RTPf -ROUND TUBE, PLATO FIN ICOPPEI/ALUNI �� - NCNX-NOVATION[ALUM/ALUM) \�� I THESE HOLES REQUIRED FOR USE RUN ACCT ZITS: • I/I A-1\ �,I I 192510 1325ja CRBINPNROO 4A01:GAS TARS BASEPAX • II \1 II I'�I RETURN AIR A I RETURN THREADED WIRE REO'D /010 1\`J/�� • CONOW SIZE USE SIZES 1MA1.1 ,� `= W 1/2' ACC. 7/6' 122.21•FILTER ACCESS PANEL I TOOL-LE551 E ALT. t }I % 1/2' 241 7/8' 122.21 CONDENSATE I Y 1 1/4'1002,0041 POIICR 1 3/4'(41.41 GRAIN OPENING CONDENSER /�� �N A IN BASEPAN 21311 COIL \, p 1731] 1055/8 I8•316 2 1 10041 311"FPT GAS 1 3/4"[11,1] SUPPLY 1955] !1027] SEE TNRU AIR [0021 PROVIDES 3/4'FPT TRH CURB INDOOR COIL • 1 Y INE BASF SUPPLY ' FLANGE%FITTING. HOLE SIlO: 2' (50.81 ACCESS PANEL r ��\ �%�-�I CHART AIR BACK u19I(1121 1° 11 THRU-THE-BASE CHART (FIOP) [7551 (2111 FOR'TNRU-TNE-BASEPAN'FACIORY OPTION, :,•• 1 I 1� — - — - — - - FITTINGS FOR ONLY A. T, 6 I ARE PROVIDED. rr 'FOR BELOW LISTED MODELS, A FIELD t-6-1/4 SUPPLIED 1/2'ADAPTER IS REWIRED -4 �-195518 11001 HOOD 3.1/4 1159] ss 48HCD.Sr085f PAN MUM AND GAS VALVE: -- 14 1831 TOP 03561 • .- -2s-vt Alt N [6471 -1-1/4 /-5/6 1321 11-718 1116] 13021 , , e f „-'Y LECTA ICNL F ! • ILTER • 1 DISCONNECT CONTROL BOX A. .�II LOCATION ACCESS PANEL • • E STS. •CONDENSER B, r COXDENSAT[ COIL G II Ili.' ORA1M OPTIONAL ACCESS MO BLOWER ••RETURN y OPTIONAL , J FACTORY _ FACTORY 21-i/b INSTALLED i AIR INSTALLED t DISCONNECT 21-371 OUTSIDE CONVENIENCE C� I� 11091 //----HHANDLE 13-118[� 1706] AIR OUTLET i-- F f3f I ` SUPPLY AIR f6�9] 5 HANDLE-----1=M 9 6-5/8 _ B�=1I�=lii8 11461 X00 'I' •i 00� iilsi° t 3-311 2-126-- 1 6-5/8 �'1 L �-4-318 1951 [15101 1111 19101 92111 [167] 1962/6 [177] IISS) 11131 LEFT WIDTH t- 88-1/8 110121 (22381 SUPPLY 11075] RELIEF IC FRONT AIR RIGHT AIR FLOW FLOW SKIT WE SNCICU[S 48TC 08-12 SINGLE ZONE ELECTRICAL K. 1OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TM500985 F Packaged Rooftop Builder 1.39p Page 5 of 20 • Certified Drawing for 7.5T _ • Project:Tigard Christian 03/11/2015 Prepared By: 11:47AN UN1TE0 ;4-.5.171 xis [11 x r[ [ 0 Or 100x(0*c01rox0nox seex(ssia o'txu[0'411[65 a 10aM(ns TARRIERDGIES AYO(5 OQIY(0(0 0101 1N([[19(03(01010101 10(1 1(1 pFS Irol 100 10000 A 100$ON alc[a OUTDOOR STD. UNIT LOANER CORNEA LOANER CORNER C.G. CARRIER 00090 iMTMiA0 lS11:71,16%1M!'—00—'0 A1A([A o srr.xc[Or io01 UNIT COIL TYPE WEIGHT 1O0 WEIGHT IA) WEIGHT(B) WEIGHT ICI WEIGHT(D) LBS. KG. LBS. KG. LBS. KG. LBS. NG. LBS. KG. I 1 1 181C-A06 RIFF 780 354 116' 61 156 12 209 95 _236 107 41 I/2 110541 33 7/6 18601 20 1/2 15211 4.STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. 461C-A09 RIFF 920 418 212' 96 163 83 243 110 282 128 40 1/8 110301 34 16641 23 1/8 15611 108 OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 930 422 216 98 196 69 241 112 272 123.5 42 110611 33 1/6 16411 24 1/4 16161 481C-008 RTAF 635 319 164 74.5 110 11.0 255 115.8 216 111.7 44 1/8 111401 35 5/8 19051 19 3/8[162] 1 F 930 482 228 103.5 181 05 232 105.3 283 128.5 39 3/4 110101 32 1/6 10351 18 5/6 14131 48TC-012 RIFF 940 421 231 104.9 169 65.6 234 106.2 286 129.8 39 3/4 110101 33 10301 18 I/2 14101 46TC-006 NCH 805 365.5 160 72.6 153 68.8 240 109 260 110 43 110921 36 3/6(9241 20 3/6 1511.11 48TC-012 MCNS 695 406.3 165 04 176 19.9 260 118 274 124.4 42 1/8 110691 35 1/2 19021 22 7/8 15611 RTPF -ROUND TUBE. PLATE FIN ICOPPER/ALUM) CORNER A MCNR-NOVATION(ALUM/ALUM) CORNER 8 (44g11 ,, u, 1 CORNER D ____e CORNER C TOP R V 1 . • Z • Ino : = : 00• FRONT MI WE 15100(0001 48TC 08-12 SINGLE ZONE ELECTRICAL IC, 20F2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TH500985 F Packaged Rooftop Builder 1.39p Page 6 of 20 • Certified Drawing for 7.5T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN Service Clearance • Cam. C11247 LOCATION DIMENSION CONDITION 48-In(1219 mm) •Unit disconnect Is mounted on panel grin(914 rmn) •If dimension-Bs 12-in(305 mm) A 18-In(457 mm) •No disconnect,convenience outlet option •Recommended serv€ceclearance(use electric screwdriver) 12-In(305 mm) •Minimum clearance(use manual ratchetscrewdrlver) 36-In(914 mm) •Unit has economizer B 12-In(305 mm) •If dimension-A is 36-In(914 mm) Special •Check for sources of flue products.within 10-ft of unit fresh a Ir Intake hood 35-In(914 mm) •Side condensate drain Is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessory Installed,surface Is combustible material 42-In(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry waif,another unit) D 36-In(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air Intakes within 10-ft of thls unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. china u-av Packaged Rooftop Builder • 1.39p Page 7 of 20 • Performance Summary For 7.5T Project:Tigard Christian 03/11/201E Prepared By: 11:47A11) Part Number:48TCDD08A2A5-0A0G0 ARI EER: 11.00 IEER- 12.8 Base Unit Dimensions Unit Length 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Operating Weight Base Unit Weight: 835 lb Medium Static Option 15 lb 2 Speed Fan Controller (VFD): 20 lb Total Operating Weight: 870 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge' Horizontal Fan Drive Type' Belt Actual Airflow: 3000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB. 58.7 F Evaporator Leaving Air WB' 57.6 F Evaporator Leaving Air Enthalpy' 24.76 BTU/Ib Gross Cooling Capacity: 90.10 MBH Gross Sensible Capacity' 68.90 MBH Compressor Power Input: 6.40 kW Coil Bypass Factor 0.092 Heating Performance Heating Airflow' 3000 CFM Entering Air Temp: 70.0 F Leaving Air Temp. 101.8 F Gas Heating Input Capacity: 125.0 MBH Gas Heating Output Capacity: 103.0 MBH Temperature Rise: 31.8 F Supply Fan External Static Pressure' 0.75 in wg Fan RPM' 792 Fan Power 1.79 BHP NOTE: Selected IFM RPM Range:733-949 Electrical Data Voltage Range: 187-253 Compressor#1 RLA. 13.6 Compressor#1 LRA' 83 Compressor#2 RLA. 13.6 Compressor#2 LRA• 83 Indoor Fan Motor Type' MED Indoor Fan Motor FLA' 8.6 Combustion Fan Motor FLA(ea)• 0.48 Power Supply MCA: 43 Packaged Rooftop Builder 1.39p Page 8 of 20 • • Performance Summary For 7.5T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN Power Supply MOCP(Fuse or HACK)• 50 Disconnect Size FLA. 45 Disconnect Size LRA: 227 Electrical Convenience Outlet. None Outdoor Fan[Qty/FLA(ea)]: 2/1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 99.3 95.8 85.8 125 Hz 93.5 83.9 84.3 250 Hz 77.6 75.0 80.5 500 Hz 70.0 62.7 78.7 1000 Hz 67.3 60.0 76.4 2000 Hz 67.0 58.2 72.7 4000 Hz 70.6 59.4 68.3 8000 Hz 72.7 62.1 65.1 A-Weighted 81.1 73.9 82.0 Advanced Acoustics i �3 \ iVVVJJJ� kit \� Advanced Accoustics Parameters 1.Unit height above ground. 30.0 ft 2.Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B 59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA C 53.4 51.9 48.1 46.3 44.0 40.3 35.9 32.7 57.2 Lp D 27.2 35.8 39.5.43.1 44.0 41.5 36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center,Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA Packaged Rooftop Builder 1.39p Page 9 of 20 Performance Summary For 7.5T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN C Sound Pressure Levels at Specific Distance from Unit,Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program,it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this,no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 000...., ` . ■ 1100RP 'E 1.8 �_ ,� , ,. 1.6 1.4 RPM _■` ■I��` �''�.lik eoo =. "s_f_m 5.00 BH-c 1.21.0 _ ■' ,� � co N 700 RPM a. "iii, `�_\,��` �. X0.6 ` I, ` 2.00 ki `500 RPM `,_' I�7:P.Ia- ,,, 0.4 _400 RPM _ 50 B 0.2 PPP.-- ` 0.0 III III iii III iii III iii I1 1 1111 III 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Airflow(CFM-thousands) RPM=792 BHP=1.79 Maximum RPM=1084 Maximum BHP=4.70 Note:Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.39p Page 10 of 20 •/J Unit Feature Sheet for 7.5T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN Carrie 0 WeatherMaker — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3,4,5,6,7.5,8.5,10,12.5,15 TONS STANDARD FEATURES INCLUDE: • Pu run(R-410A)HFC refrigerant • ASHRAE90.1 energy compiant • Scroll co mpmssor with internal fine break and overload protection 11,74771—i7 • • Sing le-stage cooling capsay control on 04-12 models • Tree stage cooling caps city control on 08-16 models r 4a.•.yf . 1, • SEER's up to 13.0,EER s up to 11.1 and IEER's up to 11.8 • Acutrolr'r refrigerant metering system rot '-'' ,a • Exclusive non-corrosive composite condensate pan in accordance with ASHRAE Standard 62,sipping design,side or cienterd re in t • Standard cooling operation up to i a h y�.,t t.. -down to 25`F(-4'C)with winter start kit. Rs, i • Pre-painfedexterrrpanels andprm=rcoated interiorpaneLS tested to vi; f I r ryy 500 hours salt spray protection 11 • Fully insulated cabinet -rte a� • Exclusive lGC solid-state control fpron,board diegncstir.with LED error code desgnationbumercontrollogic and energy saving indoor fan motordelay • Low f4Ox models that meet Califom is Air Quality Management Optional Louvered Hail Guard Shown • Induced draft gasheetcombustiondesign • Redundantgasvales with up to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: • Access panels with easy grip handles ���y'�n • Innovative easystsrting.no-strip screwe on u it access panels i �/,�l/11• • Two-inch disposable return air filters and Tool-less filter access door C MP • Belt drive evaporator-fan motor and pulley combin strons • New term'n al board feoiltatog simple safetycircu it troubleshooting and simplified control b ox a rre nge me nt WEATHERMAKER SERIES • Exclusive IGC solid-state control for on-board diegnostcs with LED WeatherMaker(48TC)units are one-piece gas heating.electric a rorcpde d=_sgnat con,bumercont al logic and energy saving indoor cooling units that are pre-wired and charged with Puron fan motordelsy. (R-410)refrigerant. They are factory tested in both heating INSTALLATION FEATURES: and cooling modes, and rated in accordance with AHRI • Thru-the-bottom powerentry ceps batty Standards 210/240(04-06 sizes)and 3401360(07-16 sizes). • Single pointg as and electric connections WeatherMaker units are designed in accordance with UL • Full perimeter base rail wth built-in r$7ging ad eater and fork slots Standard 1995,and listed by the Underwriters'Laboratories. • Field convertible from verticsl to horizontal airfloa for stab mounting. (16 size models require field installed supply duct cover). Approvedand certified by: STANDARD WARRANTY: • 10-yea rhest exchanger—15-yearstelnless steel option • 5-yearcornpressor AVP—li mr;.cp, • 1-yearparts • 3-yearpartson Idovation Condensercoils—where available C u.rw Mraewr • Msny optional upgrades also available Y �� ir•r••r11�a 00111101111011110 OPTION S INCLUDE BUT ARE NOT LIMITED TO: r r, y • Pr ride rL-xrkTM and RTU Open Multi Protocol DDC Controls wrs,pr • Supply and Return Air Smoke Detector.high static motor w.WMrr•rnw • Louvered condensermi guards + Economizer,daconnect and convenience outlet options • Stainless Steel he atexchangeroptnn • Corrosion resistant coil costing. • Humid i-1,12e c adaptive dehurrnd;Scation system available on all Certified to ISO 9001 • models withRTPFcondenserepil—MotorMasterIcontro•lerincluded Hinged access panels Fora co motets list of options and accessories refer to the Product Date Catalog fortis unit. Packaged Rooftop Builder 1.39p Page 11 of 20 • 10T Project:Tigard Christian 03/11/201E Prepared By: 11:47A AL J lOT Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.39p Page 12 of 20 Unit Report For 1OT Project:Tigard Christian 03/11/201E Prepared By: 11:47AN4 Unit Parameters Dimensions(ft.in.)&Weight(lb.)""' Unit Model. 48TCED12A2A5-0A0G0 Unit Length. 7'4.125" Unit Size. 12(10 Tons) Unit Width• 4'11.5" Volts-Phase-Hertz• 208-3-60 Unit Height: 4'1.375" Heating Type• Gas — Total Operating Weight: 993 lb Duct Cfg:...Horizontal Supply/Horizontal Return Medium Heat "' Weights and Dimensions are approximate. Weight Round Tube Plate Fin Coils does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size• 3/4 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 20 x 20 x 2 Unit Configuration Medium Static Option Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCED12A2A5-0A0G0 Rooftop Unit 1 Base Unit Medium Static Option None 2 Speed Fan Controller (VFD) Packaged Rooftop Builder 1.39p Page 13 of 20 Certified Drawing for 10T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN MOTES• UNITED P.O.801 MI DOS DONY(xl IS TIC 1101(247 Of GUM CDIIOI 1101 OMIT OUTDOOR K N TECHNOLOGIES 818001.II 1x0 IS D[lIY(IEN!ION Tx((01Kf3 comm.tAll 180 SIDx1ffot ol Txn[/IA.IRf q 1o(YM[0I 1. DIMENSIONS ARE IN INCHES,DIMENSIONS COIL TYPE r(Nn I NUT 1(nCOZON 0R Nsn m.o1T Glen KKs NUl camrvr(tan 11011INUC(u CARRIER 13121 (0101*T(lI E/IITI(N 00.5(11. KCE ITAYC[Or 40111.(7. IN I ]ARC IN MILLIMETES. 11 111 33 15 7/0 487E-088 RTPF 110181 16591 . 11031 2.s CENTER OF GRAVITY 19 3/0 31 104 27 7/8 CONNECTION SIZES 401C-09 RTPF 112531 19461 01081 3. DIRECTION OF AIR FLOW /9 3/8 3179416/11 15 Jl0 A 1 3y'133] DIA FIELD POWER SUPPLY NWE /8TC-Al2 RIPE 10-3/B 1125!] 1p6] (1031 � [10261 0 2 1/2.1611 DIA POWER SUPPLY KNOCKOUT 11 1N (6587 / 1 33 I 15 037/t 187E-008 RTPF 210181 - C 7 3/4•[51]DIA GAUGE ACCESS PLUG 40 908 19 3/8 NEW 15 il8 i 9 718•0227 DIA FIELD CONTROL TIRING HOLE 1125)1 1916] 11031 20.3/1 [ 3/1'•11 MPT CONDENSATE GRAIN /9 3/D 37 151'75 7/0 ECONOMIZER AL N000 F 112•-11 NET GAS CONNECTION 187E-012 RTPF (5271 _ 212531 19161 11031 (OPTIONAL) - 3//•-1/NET GAS CONNECTION 40C-008 NCXI 1101811 16581 4584321 6 2• 2511 DIA POWER SUPPLY KNOCK-OUT I8TC-012 MCHT /B 318 !T 1/1 .",--77-.7-.- _ _ - .. Q 224531 19161 121191.41 1 ^` THRU-THE-BASE CHART (FIELD INST) RTPF-ROUND TUBE,PLATE FIN(COPPER/ALUMI ' NCHY-90001ION(ALUM/ALUMI • /� '� F • 3 THESE POLES REQUIRED FOR USE WITH ACCY KITS: '� 36-318 12.5/0 CRBTNPWR002A01:GAS THRU CURB • ®,(�„, 19251 I 13217 CRBTNPNROO IA01:GAS THRU BASEIAN ' U'`"`�'� ��j RETURN AIR •I 1 RETURN THREADED NIA[ ROOD HOLE a `� �\\, �J� AIR CONDUIT SIIE USE SIZES IMA1.0 e ` 9 1/2• ACC. 7/8'122.21 FILTER ACCESS PANEL �_i I I 1/2' 24V 2/8.122.21 (TOOL.LESS) / � E ALT. • CONDENSATE Y 1 1/1' (002,0011 POKER 1 3/4'111.17• DRAIN OPENING . CONDENSER IN BASCPAN 11317 31-5/8 40-3/0 �, 20-3N COIL \ 1�7�. y I N 1001)3/1•FIT 6A5 1 3//•111.11 SUPPLY 1955] 118271 111DAVL mR1,144/11' N SEE THRU AIR 10021 PROVIDES 3N'FPi TNRU CURB INDOOR COIL \C\\\\\\\ .!///////.;YI-• r THE BASE SUPPLY Y FLANGE 8 FITTING. HOLE SI1E: 2' 150.01 ACCESS PANEL i BACK 16� �\\\` �,1• CHART AIR .i 19]1112) 11 11 — I THRU-THE-BASE CHART (FIDE) I [7551 12791 ' -- 1 i + ,- - 1 .. , FOR'THRU-THE-BASEPAN'FACTORY OPTION. 'AQ�1���� �IN: - - b FITTINGS FOR ONLY K. T. 1 1 ARE PROVIDED. IN T( FOR BELOW LISTED MODELS, A FIELD `9 1/4 SUPPLIED 1/2•ADAPTER IS REWIRED "'—11-5/8 11057 FLUE --.• )111 11591 1. BEPNEEN BASE PAN FITTING AND GAS NAIVE: -- 14 1031 IBIICD,5.00 TOP 13561 •---25-1/2—+- H [647] -1-1/4 1-5/0 1321 — 11-7/8 +— 1110] (3021 • . �r I • LECTAICAL CONTROL BOY A. •I II DISCONNECT - f1LTER AONTRO PANEL E STD. CONDENSER G. ' f t CONDENSATE II f ®: _ ORAIY LIP\ I OPTIONAL ACCCESS BLOWER REA IRS y OPTIONAL , 3 (RETORT FAC70RI INSTALLED 23-T/B OU75I DC 21 INSTALLED 0l5[ONNECT 27.311 CONVENIENCE !7091 ///--- ANDLF 73-1/0 1706] AIR WTLET C F / 13}I SUPPLY AIR ' 16597 4' Y HANDLE-�� de'- II 6-510 , J. •' .I 6-118 L —1 E =ZIj 11981 ;100 1 f "1 : : OOpt nsn1 ” }1 11 Ifs/ 59-v2 2-5/0— - ' Mil-��1 E t 7 1-318 6T] 11131 115101 TIP 37 221/1 (1171 37.7/0 11777 11557 CURB !9101 29621 42.3/0 LEFT WIDTH - 88-110 022381 SUPPLY 170757 RARONETRIC AIR RETURN REIM FRONT '` RIGHT AIR FLOW MOT OAT1 00PC1010(1 48TC 08-12 SINGLE ZONE ELECTRICAL 1(Y _ TOF2 03-08-10 11-24-08 COOLING WITH GAS HEAT 481.000985 F Packaged Rooftop Builder 1.39p Page 14 of 20 • 0. li Certified Drawing for 10T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN UNTEO OGIES P1O10.1610s[1.O]7 Oe 191 i nRE u Ie n n n1 M ss c m[ OIT41 1d Nh 6 0 n 6 n1.1 u W n 6 STD. UNIT CORNER CORNER CORNER CORNER CARRIER TOO] tMa1?■06 s q i cUr6e d S[0•111717 Cunt] 4tu1Unt a n enawC1 a OUTDOOR C.G.WEIGHT•. WEIG IA] WEIGHT 181 WEIGHT(C) WEIGHT ID/ CDIL TYPE LBS. KG. LBS. KG. LBS. KG, LBS.] KG. LBS. KG. R T I 1810.808 RIPE 180 354 178 61 158 12 209 95 236 107 41 1/2 110541 33 1/8[8601 20 1/2 15111 • 6 STANDARD UNIT WEIGHT IS WITH 10W GAS HEAT AND WITHOUT PACKAGING. 481C-809 RTPF 920 418 212 96 183 83 243 110 282 128 40 1/8 110381 34 18641 23 1/8 15871 FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 4811-812 RIPE 930 422 216 98 196 89 _247 112 272 123.5 42[10671 33 1/8 18411 24 1/4[6161 481C-008 RIPE 835 379 164 11.5 110 71.2 255 115.8 246 111.7 44 7/8[11101 35 5/8 19051 19 3/8[4921 930 422 228 103.5 187 85 232 105.3 283 128.5 39 3/4 [10101 32 1/8 18351 18 5/8 1473] 401C-I12 RTPF 940 421 231 104.9 189 85.8 274 106.2 286 129.8 39 3/4 [10101 33 1838] 18 1/2 14701 4 C°wo HO 805 365.5 168 12.6 153 69.5 240 109 260 118 43 110921 36 3/8 19241 20 3/6 1511.11 481C-012 NCH8 895 101.3 185 81 176 19.9 260 118 271 124.4 42 7/8 110891 35 1/2 19021 22 1/8 15811 RIPE -NCNB-NOVA 14C/01 IALULATE FIN ICOPPERIALUN7 CORNER A CORNER B 1 T \` Jj 1.!1,,1111 //.1/aU ii/ CORNER D e CORNER C TOP - K { } • • 1 2 - © P 100 rr='7 — 'C= : : 00 FRONT hill WI SPUMES 48TC 08-12 SINGLE ZONE ELECTRICAL IKI 2OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TM500985 F Packaged Rooftop Builder 1.39p Page 15 of 20 • Certified Drawing for 10T Project:Tigard Christian Prepared By: 0311 1/201E 11:47AN Service Clearance 0 • • • • i\\ C11247 LOCATION DIMENSION CONDITION 48-II(1219 mm) •Unit disconnect Is mounted on panel 36-In(914 mm) •If dimension-8 Is 12-In(305 mm) A 1844r(457 mm) •No disconnect,convenience outlet option •Recommended service clearance(use electrIcscrewdriver) 12-In(305 mm) •Minimum clearance(use manual ratchetscrewdriver) 36-In(914 mm) •Unit has economizer B 12-in(305 mm) •If dimension-A a 36-in(914 mm) Special •Check for sources of flue products within 10-ft of unit fresh air intake hood 364n(914 mm) •Side condensate drain is used 18-In(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessoryinstalled,surface Is combustible material 42-In(1067 mm) •Surface behind servkxris grounded(e.g.,metal,masonry wall,another unit) 0 36-In(914 mm) •Surface behind serviceris electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air Intakes within 10-ft of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. asst saa Packaged Rooftop Builder 1 .39p Page 16 of 20 • Performance Summary For 1OT Project:Tigard Christian 03/11/201E. Prepared By: 11:47AN Part Number:48TCED12A2A5-0A0G0 ARI EER: 11.10 IEER• 12.8 Base Unit Dimensions Unit Length. 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Operating Weight Base Unit Weight: 940 lb Medium Heat. 18 lb Medium Static Option• 15 lb 2 Speed Fan Controller (VFD): 20 lb Total Operating Weight: 993 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge' Horizontal Fan Drive Type' Belt Actual Airflow: 4000 CFM Site Altitude' 0 ft Cooling Performance Condenser Entering Air DB' 95.0 F Evaporator Entering Air DB• 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB• 57.7 F Evaporator Leaving Air WB' 57.2 F Evaporator Leaving Air Enthalpy. 24.54 BTU/lb Gross Cooling Capacity: 124.10 MBH Gross Sensible Capacity: 96.20 MBH Compressor Power Input: 8.90 kW Coil Bypass Factor: 0.046 Heating Performance Heating Airflow: 4000 CFM Entering Air Temp: 70.0 F Leaving Air Temp' 112.6 F Gas Heating Input Capacity: 180.0/224.0 MBH Gas Heating Output Capacity: 147.0/184.0 MBH Temperature Rise: 42.6 F Supply Fan External Static Pressure' 0.75 in wg Fan RPM' 891 Fan Power 2.17 BHP NOTE: Selected IFM RPM Range:838-1084 Electrical Data Voltage Range: 187-253 Compressor#1 RLA' 15.6 Compressor#1 LRA• 110 Compressor#2 FLA. 15.9 Compressor#2 LRA• 110 Indoor Fan Motor Type' MED Indoor Fan Motor FLA' 10.8 Combustion Fan Motor FLA(ea)* 0.48 Packaged Rooftop Builder 1.39p Page 17 of 20 • • M •a Performance Summary For 10T Project:Tigard Christian 03/11/201E Prepared By: 11:47AN Power Supply MCA: 50 Power Supply MOCP(Fuse or HACR)• 60 Disconnect Size FLA. 52 Disconnect Size LRA: 305 Electrical Convenience Outlet: None Outdoor Fan[Qty/FLA(ea)]: 2/1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 99.2 95.1 89.0 125 Hz 94.8 83.3 83.1 250 Hz 81.1 72.9 80.5 500 Hz 73.2 64.2 78.5 1000 Hz 70.2 62.4 75.5 2000 Hz 68.4 61.4 71.6 4000 Hz 73.1 62.7 69.6 8000 Hz 74.5 64.5 69.3 A-Weighted 82.8 74.0 82.0 Advanced Acoustics SI Q ._ L, .. _1:-id : sal Itt tlit Et 0 `0 0 Advanced Accoustics Parameters 1. Unit height above ground 30.0 ft 2.Horizontal distance from unit to receiver* 50.0 ft 3. Receiver height above ground: 5.7 ft 4.Height of obstruction: 0.0 ft 5.Horizontal distance from obstruction to receiver: 0.0 ft 6.Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 89.0 83.1 80.5 78.5 75.5 71.6 69.6 69.3 91.0 Lw B 62.8 67.0 71.9 75.3 75.5 72.8 70.6 68.2 81.1 LwA C 56.6 50.7 48.1 46.1 43.1 39.2 37.2.36.9 58.6 Lp D 30.4 34.6 39.5 42.9 43.1 40.4 38.2 35.8 48.7 LpA Legend A Sound Power Levels at Unit's Acoustic Center,Lw Packaged Rooftop Builder 1.39p Page 18 of 20 . � , Performance Summary For 10T Project:Tigard Christian 03/11/201: Prepared By: 11:47AN B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program,it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this,no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 =kIIIIIIIMIII6111 Mr RPM lairl 200 RPM OE 11■mm■........ ■ 11. ■ i 1.4 E-■,-F1'mil 800 RPM d 1.2 �- `-®-11 to co 0.6 i�M`► ► � `I.vilsk co Eillift7011112- Mk ■Pr- 500 RPM _h ,� 1 2.0 F,,, • 0.4 400 RPM Milli _-� 0 BHP 02 liwildw--. -.14Nimir 0.0 _____-•=11.1 ■ 16 A 0.0 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 Airflow(CFM-thousands) RPM=891 BHP=2.17 Maximum RPM=1084 Maximum BHP=4.70 Note:Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.39p Page 19 of 20 • • • • M Unit Feature Sheet for 10T Project:Tigard Christian 03/11/2015 Prepared By: 11:47AN Carrier (.1://1 WeatherMaker — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3,4,5,6,7.5,8.5,10,12,5,15 TONS STANDARD FEATURES INCLUDE: • Puron(R-410A)HFC refrigerant r� • ASHRAE90.1 energycomp Gant (� s` - "c.--"a • Scroll co mpressor with internal line Weekend overload protection•I t • Single-stage cooling cap Body contro l on 04-12 models D tt_ F • Two-stage cooling cepscty control on 08-16 models ••:',„'•f • SEER's up to 13.0,EER's up to 11.1 and IEER's up to 11.8• Air ". 1 • i • Acutrotr"refrigerant metering system • Exclusive non-corrosive composite condensate pen in aom rd snce with AS NRAE Sts nds rd 62,sloping deign,side or Dame r d ra in it • • Standard poling operation up to115'F(45'C)end down te40'F(4'C) • -down to 25'F(-4'C)with winter start kit. +': • Pr-printed exterior peneis end pnmer-oosted interior panels tested to 500 hours salt spray protection -'°`..- -'.. • Fully insulated cabinet • Exclusive[GC solid-state control for on-board diagnostics with LED errorcode designation bumercontrol logic and energy ssving indoor • '.R. fan motordetay Optional Louvered Hail Guard Shorn • Low NOx models that meet California Air Quality Management • Induced draft gas hestconuustion design • Redundant asve Ives with up to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: Ft • Accesspe nets with easy grko handles • Innovative easy stading,no-strip screws on unitecoess panels Puron • Two-inch disposable return a vf,!rs and Tool-less filter access door C NP..__ 1-f '" • field rive evaporator-fan motor and pulley combinatons • Newterm'::nel board facilleting simple safetycircuit troubleshooting and simplified control box a rra nge rnent WEATHERMAKER SERIES • ExclusweIGCsolid-state control for on-bosrddisgnosticswdhLED enorc dedesignetion,burnercontrollogicandenergyssvingindoor WeatherMaker(48TC)unitsareonepiecegasheating,electric cooling units that are pre-wired and charged with Puron fan motordeley. (R-410)refrigerant. They are factory tested in both heating INSTALLATION FEATURES: and cooling modes, and rated in accordance with AHRI • Thru-the-bottompoaerentrycapebdiity Standards210/240(04-06 sizes)and 340/360(07-16 sizes). • Single point gas and electric connections WeatherMaker units are designed in accordance with UL • Full pe rirreter base rail with bust---are rigging ado ptec-,s rid fork slots Standard 1995,and listed by the Underwriters'Laboratories. • Field convertible from vertical tohoreontolerfe,vforslabmounting. (16 size models requas field installed supply uct cover). Approved and certified by: STANDARD WARRANTY: • 10-year heat exchanger-15-ye ersteinlesssteel option ■� • 5-year compressor 11.• SCE RFIFIED_ • 1-yesrperts -- - • 3-ye orperts on Iteration Condensercogs-where available yApM WOW Me ny opt upgrades also available 'V s—v—a C US nr OPTIONS INCLUDE BUTARE NOT LIMITED TO: ar.Mn�aa,•..s�ar • Preme rLinkT"and RTU Open Multi Protocol DOC Controls rn>dr.a^e • Supply and Return Ai Srnolos Detectors,high static motors y `RYA° • Louvered condensercoll guards • Economer,disconnect and convenience outlet options • Sts finless Steel he at exchangeroption • Corrosion resistant cot coating. • Hu midiMiZer`adaptive dehumidification system evadable on at Certified to ISO 9001 • modes with RTPF condensercofa-Motor Master I controller included • Hinged access panels Fora complete list of options a nd accessories refer to the Product Data Catalog forthis unit. Packaged Rooftop Builder 1.39p Page 20 of 20 a f S °iY ,4,1 ,,. . . P 1. • PTA e • L•71 I .Y • fl rt� 4 r f Al . fir..!"';,4 . 1. ,t _. Yr•L _ �i• y .. , I tit • r M •• . .0 .yli . • _ Google earth i GooQ1e earth feet 100 meters 50 A \-2 Li a 5- 5 cAi (AA\ \-3(uck,. 7 \ 5c‘(-c 6 RECEIVED • MAY 4 2015 CITY OF TIGARD BUILDING DIVISION I i 1 1 ♦�'3 �-1xyAV , , t t X4y ` ,,f' b; .•9 5 ' f 3 c r., * e • y. ,z zr� zy, °�► 4r:'. y _ ati �a�Ay ,r (0 R•' *fir fi >: —`y 1•/ t•.4''..4,),-;_i y: ,i,•t Ee� 4 4 ,; •. •'. . � i . ,. _ ��- < :#21) ' - ' Y- ° r'''''' :. , s i 9 i "xt' } F r s .ti • '' + 4 a � ., . it ii Ile milf,11441I0•61$11 II. . gal moor : a 3 ,• hi 0 << { v:,,,..: aiLk• .1;1'. ir, v. .-. . +Swr.,3w..r:4rdi�'r.>ch+'"°, ` ... :. - ..':..Y.+..,1cct �•.ti, —-+o • • F.',7.,,:-,''' - ".,,,...,' ro,,.r...."; `.. • • • ' '• "1- 'jilillilliti4 ,.•1: '4;;;:.-' ..' "V.. '.. ' - alillil, . ,,,,.,A•`,..-4-713.''6.{. -.{ t- Tr - • et r ialt d ! �s14 a. + , • # ' - - ',.47. • , .•. . . •': l'I' • ''' t L_. ille11111 ril...1.1. . „, . -xt. , r X111_ ''•:"'.....-`.i.'*,./P"'-.:".'''''•'•.'‘ ''. ?, --:-.1110, V-N.0% RECEIVFD Certified Drawing for 7.5T Project:Tigard Christian MAY 4 P 2015 03/11/201 Prepared By: CITY OF TIGARD 11:47001 BUILDING (`DIVISION �N77[I P,O.RDr 1101 fKf aC1eEYt{S 101[PKIr[ri M r�p)rl r0lfarlb Ilifla C7 NI{I g1.11{,}a OO(u(�rt 10111 Otl70001 3�ie fl�i (OIY(R (HOER COORER tpI1ER 002110L061(3 601,,111.1r 10 If 11lntm rta 111 111 r 1X41 I M( f 11[7614 IAI 021601 f61 1E 06017 ICI tr[(6*i 181 C.G. Utt[(R 17!71 cariles.slx lsrk 041Ca rir.ew tulrtA IIf6 Npr Mf11 4y rt a 1011 Tiff . salaaua3 w1rx4IaI41{' K«rlutt a<ai3u IBS. 46. L68. ti. IBS. KG. 1.85. 06. L85. 46. 1 1 2 481C•418 4107 781 354 178 81 158 72 209 15 230 107 61 Ill 110541 33 148 18401 20 112 15211 446 STANDARD 0811 021601 15 011*L011 643 NEAT 4240 811■311 PACK461146. . 687(•409 0121 120 410 212' 10 183 33 .243 III 282 128 40 713 110381 14(4441 23 118 15871 70*010110 M770t5 400 4CC[95031[S.111[1 10 133 10043(7 0420(6143 6. 481,1+ Nr 134 422 216 18 116 81 241 (2 212 123 5 42 110611 33 Ill 18411 24 1/4 16161 e`grC-800 0227 835 311 164 14.5 (10 77.2 755 115.8 266 III.1 44 148 121401 35 5011 11051 11 313 14121 • 48ft`001 r 130 422 228 1•3.5 187 03 232 105.3 2113 128.5 31 314 110107 22 718(8351 18 511 14731 4843•072 1 3227 •140 423 231 114.1 18$ 03.1 034 106.2 286 171.031 311 170104 33 18381 18 112(4241 187(•100 KU 805 343.5 161 73.4 153 69.5 240 101 2p 110 43 110121 36 340 49763 24 370(511.11 481(•012 11(00 815 406,3 015 84 176 11.1 260 118 274 124 4 42 748(10891.35 112%(1021 20 718 13811 t2Pr-30808 TIRE. PLATE TIM 1(gP(1/AL0M7 CORNER A 1(017-7310110/711,18441011 CORNER 8 • .rt _._ —. — .,.. _ 1 1 1; 1 I \\_ - - 1, 1; 38AmX01`'1G S� S 41 l ff .,, s I a Its"Die. . C3)PtSe1Q-SVO ► � - �/ 4�.Ccia. • - • . . 4r __ ° — — . CORNS' • ' • I TOP --"'CORNER C 5)(05-[1 4X '' 7 W OCA CJU24E, 1. ,.., O h.•0 �� • • p.,, um 4116 siPmNt 48TC 08-12 SINGLE ZONE ELECTRICAL 417 - tort 03-08.10 ( 11-24.08 COOLING WITH GAS HEAT 48701500985 F it Packaged Rooftop Builder 1.39p Page 6 of 20 • Certified Drawing for 10T Project:Tigard Christian Prepared By: 03117/201 11:47A 00(163 q3.w¢WI 1 II 0/1w[n 1G I1(MK(11111 6101 Aww1i tl 1,— STD,tlllT LOMER CDROLR CORMR CORRCR �y/7,G Mgt C.6137 0r4(1I1.Pr +9 is XLIY7X0110P t1 [1x331 f110t1Itl n.s{[ 771w a TAKt wsP131 a 1XwA;.r1 ow W100D1 1FIGA7 rn NEVI%) 11£16XT 16h 0(IGxT(<1 •(1GxT sDl C_G. '�i/CMti[t 1>u1 ian.rs nu w11�1 /a rx/.ltrew cw710 s'°'tavrnrt rx1 rpw.0 w COIL 7TP( <WOU1ttlg4111 K<PLK(01 ttl1uR,. LBS. 114.IOIC-008 NW 760 3(1 '161 6G 156 12 209 13 236 (7 At 112K[40SI) 33 1/1(6601 20 772 15211 114 5(44446*Wilt 11(637 I5 NMI LOC GAS OEAT Apo 0(TOOOT PACKAGING. 4413-409 RIPE 130 418 212 96 163 63 243 110 262 126 4I 7/6[[0361 34 15617 73 1/6 15871 10$070(2 007[001 AND 0336510117(5.REFER TO 106 MOCK DATA CATALOG 1073.412 6111 120 472 216 94 106 36 247 112 I72 123 5 12 140611 33(10 16411 21 Ill(6161 4016-000 0711 635 371 164 74.5 176 17.2 255 115.6 216 111 7 14 7/6 0140135 5/8 11031 is 378 74021 130 122 220 1115 107 IS 231 103.3 283 126.5 3)3110 111101 32 176(633) 10 378 1473) 1673.312 R1PI 140 177 231 101.1 111 65.0 233 106.2 206 129 6 31 311 110111 33 16303 16 112[4701° 1 • I 605 3)5.3 160 72.6: 111 61.5 240 III 240' 106 10(70921 36 318(1211 20 310 1317.77. 1113.012 Ku NS 406.3 165_ 64 - 776 71.0 264 114— 37A)171.1 12 716 11403) 55 172 1902) 27 711(5011 11P7•106N0 TUBA.PLAT(771 ICCPPCI 14(31 NCO•*004T(90 1413/43X!1 CORNER A CORNER 8 1 . T 3/ Y 8 di . m X4 b' 5 aV'°re,r Uat1J.0,3 C `1k3,Q-c.lce C.' ER D • r ORDER C TOP <:::: 5_- ,— L!_ ;r4 kt x WQCo C..0 I. p 1. 63(1 u14 IPlKIX1 481C 08-12 SINGLE ZONE ELECTRICAL 1, 2 OF 2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48714500985 F , Packaged Rooftop Builder 1.39p Page 15 of 20 1 • r 1..