Report Gmail ,Finalpection Report- 13862 SW 90th Ave https://mail.google.com/mail/u/0/?ui=2&ik=b02b236125&view=pt&se...
Griai Brad Rule<bradirule@gmail.com>
aCdxxtk
Final Inspection Report - 13862 SW 90th Ave
2 messages
Sara Walker<swalker @earthadvantage.org> Wed,Apr 16,2014 at 2:16 PM
To: "bradirule @gmail.com"<bradirule @gmail.com>,"cwiegel @pcez.com"<cwiegel @pcez.com>, "pbrown@earthadvantage.org"
<pbrown @earthadvantage.org>, "vcrosby @earthadvantage.org"<vcrosby @earthadvantage.org>
earthadvantage INSPECTED FOR QUALITY Ef
■1111111111■ RESIDEN tL Portland Oregon I earthadvantage.org
Final Inspection Report
Inspection Date: 4/16/2014
Builder: Gertz Fine Homes
Subdivision: Edgewood
Lot#: 14
Address: 13862 SW 90th Ave
City: Tigard
Certifications: Earth Advantage
Solar Elements: No
Re-inspection Required:
Required Action: None
Notes:
This project had a target of Earth Advantage Silver. When I tallied up the points on the Point
Sheet,it reached Earth Advantage Gold.
Three things I saw on the point sheet that this project did not appear to have were extended
eaves,concrete patio(the deck in the back is wood),and a central vacuum. I added in points
for the Toto Water Sense toilets and the tree that was planted in the front yard.
Final Inspection Results
Insulation Inspection: Pass
Thermal Enclosure Checklist: Pass
Earth Advantage Measures: Pass
Blower Door Test Results
Maximum Allowed ACH @ 50 Pa:5.0(for Earth Advantage)
Tested Fan Flow(CFM @ 50 Pa):1
Blower Door Score(ACH @ a):3.09
To better serve you,we measure and report the actual airflow rote of bathroom exhaust fans and
the ventilation system(when feasible). These flows serve as an indicator of the quality of duct
installation and to ensure that all equipment is capable of meeting ASHRAE 62.2.
Bath Fan Test Results
1st floor bath(CFM):55 continuous/75 boost
2nd floor hall bath(CFM):79
Master bath(CFM):78
1 of 2 4/17/2014 8:45 PM
Gma Finahlnspection Report- 13862 SW 90th Ave https://maiLgoogle.com/mail/u/0/?ui=2&ik=b02b236125&view=pt&se...
Laundry(CFM):30 continuous/80 boost
To meet ASHRAE 62.2,all bathroom fans must be capable of exhausting at least 50 CFM.This
requirement only pertains to bathrooms with showers,tubs,spas,or similar sources of
moisture(not half baths or rooms with toilets only).
Ventilation Test Results
Required ventilation(continuous CFM):79
Tested ventilation flow rate(CFM): 55+30=85
Controller/Fan Setting:Laundry fan set at 30 cfm/60 min,bath fan set at 50 cfm/60 min
http://www.earthadvantage.org/
http://www.ductsinside.org/
Please take this brief survey to tell us how we're doing: http://www.surveymonkey.com/s/RVLY2T7
Valerie Crosby <vcrosby @earthadvantage.org> Wed,Apr 16, 2014 at 2:44 PM
To: Sara Walker<swalker @earthadvantage.org>
Cc: "bradirule @gmail.corn"<bradirule @gmail.corn>, "cwiegel @pcez.com"<cwiegel @pcez.com>, "pbrown @earthadvantage.org"
<pbrown @ea rthadvantage.org>
Thank you for being so thorough, Sara.
I also wanted to let everyone know that we have already submitted the final energy model for this home to Energy Trust of Oregon so that
you can, hopefully, have a final EPS for the Ultimate Open House tour.
Best,
Valerie Crosby
Technical Department Manager
E vcrosby @earthadvantage org
C 503.701.1199
Earth Advantage II Better Buildings Now
earthadvantage orq /po