Report w Page 1 of 7 ® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION The Viking Micromatie Standard Response Pendent VK102 Sprinkler is a small, thermosen- sitive, glass-bulb spray sprinkler available in several different finishes and temperature rat- 7, ; ings to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where • colors are desired. In addition, these coatings have been investigated for installation in cor- rosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS RECEIVEI ' ' �l us cULus Listed: Category VNIV Z015 FM Approved: Class Series 2000 APR 3 0 vds] VdS Approved: Certificate G414006 & G414004 CITY OF TIGARD LPCB Approved BUILDING DIVISION CC CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and UL Design Criteria on pages cULus Listing requirements, and refer to Approval Chart 2 and FM Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar)wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-1/4" (57 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi(0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Viking Technical Data may be found on Material Standards: The Viking Corporation's Web site at Frame Casting: Brass UNS-C84400 or QM Brass http:/lwww.vikinggroupinc.com. Deflector: Phosphor Bronze UNS-C51000tt or Copper UNS-C19500 The Web site may include a more recent Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with edition of this Technical Data Page. PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap- ENT plated. ttNot for FM Approval. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® Standard Response Pendent VK102 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, Black PTFE = N, Wax Coated = C, Wax Over Polyester= V-AN, ENT= JN Form No. F_031414 Rev 14.1 (New Page for VK102) F Page 2 of 7 ® MICROMATIC° STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Temperature Suffix: 135 °F (57 °C) =A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 212 °F (100 °C) = M, 286 °F (141 °C) = G, 360 °F (182 °C)= H, 500 °F (260 °C) = L, OPEN =Z (PTFE only). For example, sprinkler VK102 with a 1/2" thread, Brass finish and a 155 °F (68 °C)temperature rating = Part No. 12987AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B* (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) D. Wrench for Wax Coated Sprinklers: Part No. 13577W/B* (available since 2006) *A'A"ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromati&Standard Response Pendent Sprinkler VK102 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_031414 Rev 14.1 Page 3 of 7 NiluNG 8 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Ultra High' 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings`: White Polyester, Black Polyester,and Black PTFE in all temperature ratings. ENT in all tempurature ratings except 135 °F (57 °C). Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: 135 °F (57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Dk. Brown Wax' 286 °F (141 °C) Dk. Brown Waxy Footnotes 1 The sprinkler temperature rating is stamped on the deflector_ 2 Based on NFPA-13. Other limits may apply,depending on fire loading,sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300 °F(149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149 °C), response time may be severely retarded. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester,ENT,and PTFE coatings. For PTFE coated open sprinklers only,the waterway is coated. For ENT coated automatic sprinklers, the waterway is coated. `-Wax melting point is 170°F(76°C)for 212 °F(100°C)and 286°F(141 0C)temperature rated sprinklers. Protective Sprinkler Wrench Flat Clip JAL. Ott. _ • Protective Sprinkler Cap 10896 • Form No F_03141,ti 14-Itandard Sprinkler Wrench 10896W/B • Page 4 of 7 N1K1NG. MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Temperature KEY Micromatic5 Standard Response Pendent Sprinkler VK102 + Finish i Maximum 175 PSI(12 bar) A ~-Escutcheon pi appen>e� WWP Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' Base Part SIN (Refer also to UL Design Criteria.) Number' NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB (E Standard Orifice 12987 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al, B4, B1Y, C5, D3, E6,G6Z A2 A2, B4, B2Y F2, G2Y 12989 VK102 -- 15 mm 5.6 80.6 2-1/4" 57 Al, 84, B1Y, C5, D3, E6,G6Z A2 A2, B4, B2Y F2, G2Y Approved Temperature Ratings A- 135°F(57°C), 155°F(68°C), 175°F(79°C), 200 °F(93 °C), 286 °F (141 °C), and 360 °F (182 Approved Finishes °C) Approved Escutcheons 1 - Brass, Chrome, White Polyester , Black Polyester se, and B- 135°F(57°C), 155°F(68°C), 175°F(79°C), Black PTFE5 Y-Standard surface-mounted es- and 200°F(93 °C) cutcheon or the Viking Microfast® 2-Brass,Chrome,White Polyester",and Black Polyester`' Model C-286°F(141 °C) F-1 Adjustable Escutcheon 3- Brass and Chrome or recessed with the Viking D-500°F(260°C)' Micromatic® Model E-1, E-2, or 4-Wax-Coated Brass and Wax Over Polyester` E - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 E-3 Recessed Escutcheon °C), 286 °F(141 °C), 360°F(182 °C), and 500°F 5- High Temperature 200°F (93 °C) Wax Coating (corrosion (260°C' resistant); maximum ambient temperature allowed at ceiling= Z - Standard surface-mounted 150°F(65°C) escutcheon or recessed with the F- 155°F(68°C), 175°F(79°C),200°F(93°C), Viking Micromatic®Model E-1 286°F(141 °C), and 360°F(182°C) 6-ENT' G - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93°C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals 'Listed by Underwriters Laboratories Inc. for use in the U.S.and Canada. cULus Listed as corrosion resistant. E Other colors are available on request with the same Listings and Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149°C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. ((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. • PESIGN CRITERIA- UL . . 11 � (Also refer to Approval Chart 1.) s i cULus Listing Rirements: I The Viking Micromatic°F'Standard Response Pendent Sprinkler VK102 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light, Ordinary. and Extra Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, FSr� Ibl,v 14 1 Page 5 of 7 ® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) •• —' --Temperature • Micromatic�'Standard Response Pendent Sprinkler VK102 w ---Finish KEY Maximum 175 PSI(12 bar)WWP ,AIX 4-Escutcheon tit applicable) Sprinkler Base SIN Thread Size Nominal K-Factor Overall Length FM Approvals' Part Number' NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) Standard Orifice 12987 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al, B2, C3, D1, E4, F1Y, G4Z 12989 VK102 -- 15 mm 5.6 80.6 2-1/4" 57 Al, B2, C3, D1, E4, F1Y, G4Z Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C). 212 °F (100 °C), 286°F(141 °C), and 360°F(182 °C) Approved Finishes Approved Escutcheons B- 135°F(57°C), 155°F(68°C), 175°F(79°C),200°F 1 - Brass, Chrome, White Polyester', and Y - Standard surface-mounted escutch- (93°C),and 212 °F(100°C) Black Polyester' eon or the Viking Microfast® Model F-1 C-286 °F(141 °C) 2-Wax-Coated Brass(corrosion resistant) Adjustable Escutcheon or recessed with the D-500°F(260°C)5 3 - High Temperature 200 °F (93 °C) Wax Viking Micromatic®Model E-1, E-2, or E-3 E- 155°F(68°C), 175°F(79°C),200°F(93°C),286°F Coating (corrosion resistant); maximum am- Recessed Escutcheon (141 °C), 360°F(182°C), and 500 °F(260°C)5 bient temperature allowed at the ceiling = Z - Standard surface-mounted escutcheon 150°F(65°C) or re- cessed with the Viking Micromatic® F - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 4-ENT6 Model E-1 200°F(93°C) G- 155°F(68°C), 175°F(79°C), and 200°F(93°C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. °Other colors are available on request with the same Approvals as the standard colors. 5 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149°C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. FM approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart 2.) FM Approval Reauirements: The Viking Micromaticc Standard Response Pendent Sprinkler VK102 is is FM Approved as standard response Non-Storage pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements. reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to minimum water supply requirements, hydraulic design, ceiling slope and obstructions,minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to page SR1-3 for gen- eral care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031414 Rev 14.1 Page 6 of 7 ® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com ► 1. +• 4•4 il,. �0. • Sprinkler wrench 16036W/B** for recessed pendent sprinklers **A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around �_ the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers ,71" ; 11, Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- 114 ment with the sprinklger wrench flats. -41111111 � Wax Coated Pendent Sprinkler Sprinkler wrench 13577W/B** must be used for installing wax coated sprinklers. **A 1/2" ratchet is required Step 2: Carefully press the wrench upward and (not available from Viking) ensure engagement with the sprinkler wrench flats. Figure 3: Wrench 13577W/B for Wax Coated Sprinklers Form No. F_031414 Rev 14.1 Page 7 of 7 NIKING. MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com • Ceiling Opening Size: 1/2" t lit 2-5/16" (58.7 mm) minimum (15 mm) ,6' 2-1/2" (63.5 mm) maximum NPT �� M, :, 2-1/8 (54 mm) . •italliP . til 2-3/16" f 1-1/2" (56 mm) 4' " 1-3/4" 2" (38 mm) d (51 mm) Min. (44.5 mm) Max. $ Installed with a standard Installed with a Microfast Note:At maximum,adapter is 1/8" surface-mounted Model F-1 Adjustable exposed 1/2"(12.7 mm)from escutcheon Escutcheon face of ceiling Figure 4: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Ceiling Opening Size: '1-}tom , +•''f ' 2-5/16" (58.7 mm) minimum .r 2-1/2" (63.5 mm) maximum tf .'ft. t 2-1/8" 2-1/8" ,i; (54 mm) , (54 mm) # w T i 1-3/4" 2,,,, 1-118" r 1-1/8" (28.6 mm) (28.6 mm) (44.5 mm) ,.. Min. (51 mm) t: Min. Max. Max. '-z:Z.ia.t. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 5: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F031414 Rev 14.1 RECEIVED APR 3 0 2015 CITY OF TIGARD BUILDING DIVISION Egad/5--'S40 7 "P 1116 , k1A-) 63- miti/ E,s£x iI•xy A= MoD '.. #� •A A • 4-0 v Eo ♦a I I - I THIS DRAWING IS THE PROPERTY OF VIKING AUTOMATIC SPRINKLER COMPANY. IT IS SUBMITTED IN CONFIDENCE AND IS NOT TO BE DISCLOSED OR UTILIZED WITHOUT THE WRITTEN PERMISSION OF VIKING AUTOMATIC SPRINKLER CO. KING' SEATTLE RFE p 'Jy MEDFORD PORTLAND LONGVIEW SPRINKLER SPRINKLER SYMBOL DESCRIPTION BOISE VIKING A3245MNWI FRONT AVENUE LODI PORTLAND,OREGON 97210•24 hrs.(503)227-1171 SYM STYLE MFG RESPONSE THD i 'K' TEMP SIN# FINISH ESCUTCH. WRENCH QTY OREGON CCB•64337 METRO UC s T316•WASHINGTON UC I VIKI-NA-5373NT STATE OF OREGON 0 S3 Q I ktl. STb titz is,to XS" Vic taZ CM S-1 Z LICENSE 11 III III�I Pe1zs 1.0 2' 4' 6' 8' i , 11Li I O 5�_1 [os Ft�eti s Tc>��Q caz °1Trz III 1111 - - - TOTAL SPRINKLERS SHOWN ON THIS SHEET . o�p v:a T1 3 al) Woe_Woe_Drawn By: Date Drawn: Scale: Job No: Drawing No: SCALE: 1/8"=l'-0" TOTAL SPRINKLERS REQUIRED ON THIS CONTRACT - Z gicreio«+J X130!15 i8 Tiler W Olt SL 41 1