Report 58STA/STX 4—WAY MULTIPOISE INDUCED—COMBUSTION GAS FURNACE Carrie Input Capacities: 45,000 thru 155,000 Btuh Series 160 turn to the experts 0 Product Data APR 2015 �Ci�IiTnYiOFF TIGARD THE CARRIER 58STA/ST �GP�S"I?UR'Pa Q _ The 58STA/STX 4-way Multipoise Gas Furnaces feature Carrier's • QuieTech noise reduction system for incredibly quiet induced draft operation. Applications are easy with 4-way multipoise /• ■ design, through-the-furnace downflow venting, 13 different y venting options, and designed for easy service access. An inner blower door is provided for tighter sealing in sensitive applications. The 58STA/STX furnaces are approved for use with natural or propane gas,and the 58STX is approved for use in Low NOx Air O ® f t Management Districts. STANDARD FEATURES 1 "Th _ ® ,===zs • QuieTech'" noise reduction system • Microprocessor based control center Enhanced diagnostics with LED and reflective sight glass. Stores fault codes during power outages. e ® Adjustable heating air temperature rise Adjustable cooling airflow • 4-way Multipoise furnace,13 vent applications • Compact design-only 33-1/3 in.(847 mm)tall • Power Heat"' Igniter • Draft safeguard switch to ensure proper furnace venting • Inner door for tighter sealing • Certified to leak 2 percent or less of its nominal air conditioning CFM delivered when pressurized to 1-In. Water Gauge with all present air inlets and air outlets sealed. • HYBRID HEAT.Dual Fuel System compatible CITY OF TIGARD • All models are chimney friendly when used with :;�:ir,��ti��i����%i=1��1 r�v�•,•�1�= accessory vent kit • Twinning in Upflow,Downflow and Horizontal Approved: ��/�� A10247 • Residential installations eligible for consumer OTC: I I financing through the Retail Credit Program Pcrrnit#: J C 24(G-- o «© Address: ( S5 '9'2!")t) Suite .•_ n By: la Date: 41 [4 c. OFFICE COPY MODEL NUMBER NOMENCLATURE 58STA 045 100 08 58STA 4—Way Multipoise Nominal Cooling Size 58STX Low NOx version (Airflow at.5 e.s.p.) (400 CFM per 12,000 Btuh) 08-800 CFM • 12-1200 CFM 14-1400 CFM 16-1600 CFM Input Capacity 20-2000 CFM 045-44,000 Btuh 110-110,000 Btuh 22-2200 CFM 070-66,000 Btuh 135-132,000 Btuh 090-88,000 Btuh 155-154,000 Btuh Series Number FURNACE COMPONENTS to Q INDUCER MOTOR VENT F— ASSEMBLY ELBOW V) co Li) MAIN LIMIT SWITCH ::z: j II (BEHIND GAS VALVE) BLOCKED VENT FLUE 7� NNW �`�^• ` v 1I� 417::� 49- 0 FLAME GAS VALVE �.��, f�=J� SENSOR i �1 :4 r AEI r „ //I'�Ilia MANUAL RESET ��9• _ " .1 i I GAS MANIFOLD LIMIT SWITCHES ���I . ,'�'�1,i F �, HOT SURFACE �� iiiF____ ®�.�DOOFETY I -1 m `' '�4LOWER"AND =3rtag ■ rvmoi:.:0",. �•=1 I M O� :b3VOV A. I I ' � Ch'AC3OR/ POWER CHO iltk tlftf-1 1' • A10308 I NOTE: The 58STA/STX Furnaces are factory shipped for use with natural gas.These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. • 2 DIMENSIONS LI PAW lv" MA m. VP 1 EL 1 s 114,1 0 r2. $rw OnA .�. 4 I.MAnll' du MPU M'I W3 A f7M M -�� MAOW �'� II1Lf11MMa 1 OMI 0r OVCwal6 10P OF 1 I w .p nA 111 l i'l . ' „a .a� ° M a .-.12.-s- „ \ n 71117/111 if PL4M agnnoaE V VI Ill Q nwoMawaMla nm 211N6 l-- vMm wzmm — iawe I 1 I II I I — Jaoa CO LIM. IoM, nA paerC�/ JI `I /�D- 1 W yIOCICC0 R. IM gIUYM12r a� ~ 1�-moos MI MI MAI nvi' 1 o A fC[pMpJir W s� ann Al 0270 NOTES: 1.Two additional 7/8—in.(22 mm)diameter holes are located in the top plate. 2.Minimum return—air openings at furnace,based on metal duct.If flex duct is used,see flex duct manufacturer's recommendations for equivalent diameters. a. For 800 CFM-16—in.(406 mm)round or 14 1/2 x 12—in.(368 x 305 mm)rectangle. b. For 1200 CFM-20—in.(508 mm)round or 14 1/2 x 19 1/2—in.(368 x 495 mm)rectangle. c. For 1600 CFM-22—in.(559 mm)round or 14 1/2 x 22 1/16—in.(368 x 560mm)rectangle. d. For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets.The use of both side inlets, a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A B C D •VENT SHIP FURNACE SIZE CABINET WIDTH OUTLET TOP AND BOTTOM CONNECTION WEIGHT IN(mm) WIDTH BOTTOM FLUE INLET WIDTH SIZE LB(KG) IN(mm) COLLAR 045-08 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 104 (47) 045-12 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 107 (49) 070-08 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 111 (50) 070-12 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 115 (52) 070-16 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 126 (57) 090-14 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 127 (58) 090-16 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 140 (64) 090-20 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66) 110-12 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 135 (61) 110-16 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66) 110-22 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 152 (69) 135-16 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102)* 149 (68) 135-22 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 163 (74) 155-20 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 170 (77) *135 and 155 size furnaces require a 5 or 6-in. (127 or 152 mm)vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements. 3 SPECIFICATIONS 1111Rf�L{e 045-011, 04$-12" ` 070.1': . 070,22 7. 070'1$ '090x14 , 191D-16 RATINGS AND PERFORMANCE Input Btuh* 58STX Upflow;all 44,000 44,000 66,000 66,000 66,000 88,000 88,000 58STA Nonweatherized ICS 58STX Downflow/ 42,000 42,000 63,000 63,000 63,000 84,000 84,000 Horizontal Output Capacity 58STX Upflow;all 35,000 36,000 53,000 54,000 53,000 71,000 71.000 (Btuh)t 58STA Nonweatherized ICS 58STX Down(low/ 34,000 34,000 51,000 51,000 51,000 68,000 68,000 Horizontal AFUEt 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range-°F(°C) 30-60 20-50 40-70 30-60 25-55 40-70 30-60 (17-33) (11-28) (22-39) (17-33) (14-30) (22-39) (17-33) Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 X Heating 865 1250 ' 720 1195 A 1350 1300 1505 Airflow CFM# v) Cooling 835 1160 870 1200 1505 1385 1635 Q I- CD 00 Unit Volts-Hertz-Phase 115-60-1 rn Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.2 7.2 5.1 7.2 9.5 8.6 10.0 Maximum Wire Length(Measure 1 Way in Ft(M) 49(14.9) 37(11.2) 51 (15.5) 38(11.5) 29(8.8) 32(9.7) 28(8.5) Minimum Wire Size 14 Maximum Fuse or Ckt Bkr Size(Amps)** 15 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 2 . I 2 I 3 I 3 1 3 I 4 1 4 Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure 4.5(Natural Gas) (In.W.C.) Max.inlet pressure . 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWER DATA Direct-Drive Motor HP(PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2 Motor Full Load Amps 2.8 5.2 2.8 5.2 7.1 52 7.1 RPM(Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 - Blower Wheel Diameter x Width - In.(mm) 10 x 6 10 x 6 10 x 6 10 x 6 11 x 8 10 x 8 10 x 10 (254 x 152) (254 x 152) (254 x 152) (254 x 152) (279 x 203) (254 x 203) (254 x 254) * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI 2223.1-2012 Table F.4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. t Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4 SPECIFICATIONS (continued) UNITSIZE 090-20 -' 110=12 110-Is • 110-52 '10.10 176-22 • 156-20 RATINGS AND PERFORMANCE Input Btuh* 58STX Upflow;all 88,000 110,000 110,000 110,000 132,000 132,000 154,000 58STA Nonweatherized ICS 58STX Downflow/ 84,000 105,000 105,000 105,000 126,000 126,000 147,000 Horizontal Output Capacity 58STX Upflow;all 71,000 89,000 89,000 89,000 107,000 107,000 125,000 (Btuh)t 58STA Nonweatherized ICS 58STX Downflow/ 68,000 85,000 85,000 85,000 102,000 102,000 119,000 Horizontal AFUEt 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range°F(°C) 25-55 50-80 40-70 30-60 50-80 40-70 45-75 (14-30) (28-44) (22-39) (17-33) (28-44) (22-39) (25-41) Certified External Static Pressure Heat/Cool 0.15/0.50 0.20/0.50 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 0.20/0.50 Heating 1900 1295 1515 1840 1480 1830 1790 X Airflow CFM# Cooling 2025 1355 1655 2160 1710 2085 2215 N ELECTRICAL H U) Unit Volts-Hertz-Phase 115-60-1 c0 u7 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 14.1 8.6 10.2 15.1 10.5 14.5 15.4 Maximum Wire Length(Measure 1 Way in Ft(M)) 31 (9.4) 32(9.7) 27(8.2) 29(8.8) 27(8.2) 30(9.1) 29(8.8) Minimum Wire Size 12 14 12 14 11 Maximum Fuse or Ckt Bkr Size(Amps)** 20 15 20 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 4 I 5 I 5 I 5 I 6 I 6 l Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure 4.5(Natural Gas) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWER DATA Direct-Drive Motor HP(PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4 Motor Full Load Amps 11.8 5.2 7.1 11.8 7.1 11.8 11.8 RPM(Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075.3 1075-3 1075-3 Blower Wheel Diameter x Width-In.(mm) 11 x 11 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11 (279 x 279) (254 x 203) (254 x 254) (279 x 279) (254 x 254) (279 x 279) (279 x 279) * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft. (305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI 2223.1-2012 Table F.4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. t Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide, high efficiency media fitter. ** Time-delay type is recommended. CS Isolated Combustion System 5 CARRIER ACCESSORIES OE1!<ORW7iON• RART140. 046 046 070 070 I070090 060. 080 110 110,-110 -186 136 166 68STAISTX 06 12 06 12 116 14 16 20 12 116 22 16 22 20 FILCABXL0016 X X X X X X X Media Fitter Cabinet FILCABXL0020 X X X X X FILCABXL0024 X X FILCCCAR0016 X X X X X X X Cartridge Media Filler FILCCCAR0020 X X X X X FILCCCAR0024 X X EXPXXUNV0016 X X X X X X X EZ Flex Media Fitter with End Caps EXPXXUNV0020 X X X X X EXPXXUNV0024 X X EXPXXFIL0016 X X k X X X X X Replacement EZ Flex Filter Media EXPXXFIL0020 X X X X X ]C EXPXXFIL0024 X X CO KGBFRO401B14 X X X X KGBFR0501 B17 X - X X External Bottom Return Filter Rack KGBFR0601 B21 X X X X X CO KGBFRO701 B24 X X External Side Return Filler Rack KGAFRO201ALL X X - X X X X X X X X X X X X KGAWF1306UFRt X X - X X X X X Unframed Fitter 3/4-in.(19 mm) KGAWF1406UFR X X X X X KGAWF1506UFR X X Flue Extension KGAFE0112UPH X X X X X X X X X X X X X X Twinning Kit KGATWO601HSI X X X X X X X X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGBVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X KGACA02014FC X X X X X X X X X X X Chimney Adapter Kit KGACA02015FC X X X Natural-to-Propane Conversion Kit* KGBNP50011SP X X X X X X X X X X X X X X Propane-to-Natural Conversion Kit KGBPN42011 SP X X X X X X X X X X X X X X Label Kit KGALB0301 KIT X X X X X X X X X X X X X X LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DB076 See Installation Instructions for model, Gas Orifice LH32DB076 altitude,and heat value usages. LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210 •Factory-authorized and field installed.Fuel conversion kits are CSA(formerly AGNCGA)recognized. t Suitable for Side Return Filter Rack X=Accessory S=Standard 6 CARRIER ACCESSORIES Accessories ELECTRONIC AIR CLEANER(EAC) Model EACB MECHANICAL AIR CLEANER Models EZXCAB,FILCAB HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL For use with 1-speed Air Conditioner-deg.F/C,Auto Changeover-TP-NAC,TC-NAC For use with 1-speed Heat Pump-deg.F/C,Auto Changeover-TP-NHP,TC-NHP' THERMOSTAT - NON-PROGRAMMABLE For use with 2-speed Air Conditioner-deg.F/C,Auto Changeover-TP-NRH* For use with multi-use/stage configurations-deg.F/C,Auto Changeover/Temperature and Humidity Control-TP-PRHt For use with 1-speed Air Conditioner-deg.F/C,Auto Changeover,7-Day Programmable- TP-PAC For use with 1-speed Heat Pump-deg.F/C,Auto Changeover,7-Day Programmable- 1-- TP-PHP" THERMOSTAT - For use with 2-speed Air Conditioner-deg.F/C,Auto Changeover,7-Day Programmable- 1-- PROGRAMMABLE TP-PRH' co For use with 1-speed Air Conditioner-deg.F/C,5-2 Day Programmable-TP-PAC For use with multi-stage applications-deg.F/C,Auto Changeover,7-Day Programmable-TC-PHP$ For multi-use/stage configurations-deg.F/C,Auto Changeover,7-Day Programmable/Temperature and Humidity Control-TP-PRHt Comfort'"Series 3-Zone Kit-ZONECC3ZAC01,ZONECC3ZHP01 2 Performance-Series ComfortZone'"II Zoning/Temperature and Humidity Control-ZONECC2KIT01-B ZONING CONTROL 4 Performance'"Series ComfortZone'"II Zoning/Temperature and Humidity Control-ZONECC4KIT01-B 8 Performancee'Series ComfortZone'"II Zoning/Temperature and Humidity Control-ZONECC8KIT01-B Model HP and 2S thermostat must be field converted to air conditioner operation. t Thermidistat Control can be configured for multiple use and staging,it must be configured for each specific application. $ Dual Fuel thermostat is used with furnace and heat pump application. TYPICAL WIRING SCHEMATIC - FIELD 24-V WIRING ---- FIELD 115-,208/230-,460-V WIRING — FACTORY 24-V WIRING — FACTORY 115-V WIRING NOTE 2 (� FIVE Q HERMOSTAT Cr) Y q Q TERMINALS FIELD-SUPPLIED WIRE I DISCONNECT I I - BLOWER THREE-WIRE __ E4 DOOR HEATING- I i T—"}e 208/230-OR SWITCH ONLY + __ �--' 460-V THREE O__i i ref PHASE 8L • �.1 0—_ I — WH HT� O --- +--' __ _ __ • , 1 208/230-V —FGND r7-r GND _ r_ __ __=l SINGLE 115-V AUXILIARY ___ i i I PHASE FIELD-SUPPLIED J-BOX O• I I GND DISCONNECT CONTROL NOTE 1 1 i CONDENSING BOX Q" UNIT 24-V TWO TERMINAL WIRE BLOCK FURNACE NOTES: 1. Connect Y-terminal as shown for proper operation. 2. Some thermostats require a"C"terminal connection as shown. 3. If any of the original wire,as supplied,must be replaced,use same type or equivalent wire. A02186 .1i Ili IN ;I7J : l '. nill; '. °S . �� - - ---.Ar i O _._ ._� ire � O 1 O lip 1111.M.! o• ri!L1 I H SEE NOTES: 1,2,4,7,8,9 SEE NOTES:1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW Q A02056 A02059 A02061 I- CI) CO in i 1, I. ' Fi ij , � rill 1 0 0 1 i- I. I glerV-fr 1 i SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,85,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material:United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in. (127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in.(102 mm)single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180° apart. 9. Secure all other single wall vent connector joints with(3)corrosion-resistant screws spaced approximately 120° apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 8 I '1 • O ,—,,, .,:') . rit 7......._,...it • Ai 1!r Its ' \I Miles 1__ ■IIW SEE NOTES 1,2,4,5,7,8,9 HORIZONTAL RIGHT SEE NOTES 1,2,4,5,7,8,9 A02068 HORIZONTAL RIGHT A02070 O X I ._co in SEE NOTES 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 a • � ; o Fa SEE NOTES 1,2,4,7,8,9 SEE NOTES 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT • A02064 A02065 kki_ii) 41-01. tj� o ' j o SEE NOTES 1,2,4,5,7,8,9 SEE NOTES 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 9 • AIR DELIVERY - CFM (With Filter) FURNACE RETURN-AIR EXTERNAL STATIC PRESSURE(In.W.C.) SIZE INLET SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Bottom or High 1035 995 945 895 835 770 675 565 390 195 045-08 Sides) Med-High 865 830 790 745 690 625 545 440 250 195 Med-Low 760 720 680 635 580 520 445 345 220 195 Bottom or High 1440 1375 1305 1240 1160 1070 975 870 730 560 • 045-12 Side(s) Med-High 1360 1300 1240 1175 1115 1040 950 850 725 575 Med-Low 1250 1210 1160 1100 1040 965 885 790 670 520 Bottom or High 1030 1005 965 925 870 810 740 645 465 280 070-08 Side(s) Med-High 835 815 790 755 710 660 590 480 325 205 Med-Low 725 700 675 635 595 545 460 350 250 Bottom or High 1425 1375 1320 1265 1200 1125 1035 940 830 655 070-12 Sides) Med-High 1320 1280 1240 1205 1140 1075 995 905 790 620 Med-Low 1200 1175 1145 1105 1050 990 920 840 725 555 Bottom or High 1755 1700 1635 1570 1505 1435 1350 1260 1160 1055 070-16 Side(s) Med-High 1550 1520 1475 1430 1375 1310 1240 1155 1070 970 Med-Low 1355 1340 1310 1280 1240 1190 1125 1060 975 890 X Bottom or High 1605 1570 1535 1465 1385 1285 1175 1055 895 645 0 090-14 Med-High 1470 1445 1410 1380 1300 1220 1115 990 830 600 Q Side(s) Med-Low 1310 1295 1265 1230 1195 1120 1025 915 710 565 I- w High 1940 1880 1805 1720 1635 1540 1425 1290 1090 830 co Bottom or 090-16 Bottom Med-High 1740 1700 1650 1590 1525 1440 1335 1195 1010 820 Med-Low 1505 1505 1480 1440 1375 1300 1190 1045 890 740 High 2405 2310 2220 2130 2025 1920 1790 1660 1530 1350 Bottom Only Med-High 2170 2110 2040 1970 1895 1785 1675 1565 1420 1260 Med-Low 1920 1875 1835 1780 1715 1630 1535 1420 1275 1135 Both Sides or 1 High 2530 2450 2365 2270 2165 2065 1940 1805 1670 1505 090-20 Side&Bottom Med-High 2230 2170 2110 2050 1985 1890 1780 1660 1525 1360 Med-Low 1895 1890 1845 1815 1755 1685 1600 1480 1350 1180 High 2475 2395 2300 2200 2090 1985 1865 1 730 1585 1425 1Side Only Med-High 2105 2145 2070 2010 1940 1845 1735 1620 1475 1325 Med-Low 1850 1860 1810 i 1770 1715 1650 1555 1445 1310 1150 Bottom or High 1600 1550 1490 1425 1355 1260 1135 990 785 530 110-12 Side(s) Med-High 1475 1435 1395 1335 1285 1185 1070 890 725 450 Med-Low 1315 1295 1265 1220 1155 1080 985 810 675 440 High 1980 1915 1835 1750 1655 1495 1365 1185 965 700 110-16 BS d(s)or Med-High 1745 1710 1650 1560 1450 1340 1205 1090 865 605 Med-Low 1530 1515 1470 1400 1310 1215 1095 990 830 670 High 2485 2415 2340 2255 2160 2080 1950 1840 1720 1565 Bottom Only Med-High 2135 2100 2060 2000 1930 1860 1765 1670 1555 • 1425 • Med-Low 1855 1840 1815 1775 1725 1675 1600 1510 1405 1290 Bottom Sides High -- -- 2355 2285 2190 2090 1965 1850 1705 1535 110-22 or 1 Side&Bot- Med-High 2140 2100 2050 1990 1935 1865 1760 1670 1545 1410 torn Med-Low 1855 1840 1815 1775 1725 1675 1600 1510 1405 1290 High 2495 2440 2370 2290 2205 2120 2015 1910 1775 1625 1Side Only Med-High 2030 2025 2000 1950 1905 1850 1750 1660 1555 1425 Med-Low -- 1735 1725 1695 1650 1595 1535 1455 1335 1230 A filter is required for each return—air inlet.Airflow performance included 3/4—in.(19 mm)washable filter media such as contained in factory—authorized ac- cessory filter rack.To determine airflow performance without this filter,assume an additional 0.1 In.W.C.available external static pressure. ——Indicates unstable operating conditions. 10 • AIR DELIVERY - CFM (With Filter) (Continued) FURNACE RETURN-AIR EXTERNAL STATIC PRESSURE(In.W.C.) • SIZE INLET SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Bottom or High 2065 2000 1930 1835 1710 1590 1420 1235 1025 835 135-16 Side(s) Med-High 1790 1755 1705 1640 1550 1465 1295 1145 945 775 Med-Low 1480 1480 1480 1450 1380 1295 1160 1005 855 670 • High 2445 2365 2280 2190 2085 1980 1850 1705 1520 1355 Bottom Only Med-High 2130 2080 2025 1960 1880 1795 1690 1550 1405 1255 Med-Low 1860 1830 1800 1755 1705 1630 1530 1415 1280 1140 135-22 Bottom,Sides High -- -- 2355 2280 2160 2065 1930 1805 1655 1465 or 1 Side&Bot- Med-High 2120 2075 1995 1970 1905 1835 1735 1645 1515 1325 torn Med-Low 1860 1830 1800 1755 1725 1630 1530 1415 1280 1140 High -- -- 2215 2130 2030 1920 1795 1675 1540 1385 1 Side Only Med-High 2070 2015 1970 1935 1855 1765 1655 1550 1445 1265 Med-Low 1860 1830 1800 1755 1725 1630 1530 1415 1280 1140 High 2465 2430 2375 2305 2215 2110 2000 1865 1715 1530 Bottom Only Med-High 2115 2095 2055 2005 1940 1845 1820 1675 1525 1390 Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 High -- -- 2375 2285 2185 2105 1995 1870 1720 1555 155-20 Both Sides Or 1 Med-High 2155 2125 2075 2015 1935 1830 1780 1635 1485 1365 (1) Side&Bottom Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 High -- -- 2260 2180 2070 1975 1865 1740 1595 1440 1Side Only Med-High 2140 2085 2020 1950 1850 1745 1695 1545 1415 1290 co Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 A filter is required for each return—air inlet.Airflow performance included 3/4—in.(19 mm)washable filter media such as contained in factory—authorized ac- cessory filter rack.To determine airflow performance without this filter,assume an additional 0.1 In.W.C.available external static pressure. ——Indicates unstable operating conditions. 11 A WARNING -, INSTALLATION FIRE,EXPLOSION, MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ASPHYXIATION HAZARD This forced air furnace is This furnace is approved for • equipped for use with natural UPFLOW, DOWNFLOW, and Improper adjustment,alteration,service, gas at altitudes 0- 10,000 ft HORIZONTAL installations. maintenance,or installation can cause 0- 3,050m . t• Clearance arrows serious injury or death. { ) �„,,, do not change with J ►Y An accessory kit, supplied by ? furnace orientation. the manufacturer, shall be used W Read and follow instructions and to convert to propane gas use ' precautions in User's Information Manual or may be required for some BACK sy°f *t7 and ervicetmust be performed by a on n This If 9 furnace is for indoor 09- tic qualified service agency or the gas installation in a building Flo SERVI supplier. constructed on site. °E Fa `E This furnace may be installed 5 °"T tcae A CAUTION on combustible flooring in alcove *O" 01 Mk or closet at minimum clearance i; X Check entire gas assembly for leaks after as indicated by the diagram H lighting this appliance. p" cn from combustible material. t Clearance in inches Q This furnace may be used with INSTALLATION a Type B-1 Vent and may be Vent Clearance to combustibles: co vented in common with other to For Si Wall vents 6 inches(6 1.This furnace must be installed in gas fired appliances. ( Po) accordance with the manufacturer's For Type B-1 vent type 1 inch(1 po). instructions se absence of aca local codes. the the MINIMUM INCHES CLEARANCE TO absence of local codes,follow the National Fuel Gas Code ANSI Z223.1 /NFPA54 COMBUSTIBLE CONSTRUCTION or CSA B-149. 1 Gas Installation Code. 2.This furnace must be installed so there are DOWNFLOW POSITIONS: provisions for combustion and ventilation air. See manufacturer's installation t Installation on non-combustible floors only. information provided with this appliance. For Installation on combustible flooring only when installed on special base, Part No.KGASB0201ALL or NAHA01101 SB, Coil Assembly, MitOPERATION Part No.CAR,CAP,CNPV,CNRV,END4X,ENW4X,WENC,WTNC, This furnace is equipped with manual reset WENW OR WTNW. limit switch(es)in burner compartment to 0 18 inches front clearance required for alcove. protect against overheat conditions that • can result from inadequate combustion air 1k Indicates supply or return sides when furnace is in the horizontal supply or blocked vent conditions. position. Line contact only permissible between lines formed by 1. Do not bypass limit switches. intersections of the Top and two Sides of the furnace jacket, 2. If a limit opens,call a quallified and building joists,studs or framing. 111111111111111111111111111111■®III�I�� serviceman to correct the condition and reset limit switch. ` 336996-101 REV.C J A10269 ETM a> v snail' ...1 CERTIFIED,.. ` � ' Always Ask For IKI cn C ,.wv..abritllreclory.org a_ CU OI� u11 "— Use of the AHRI Certified T.Mark indicates a a i manufacturer's participation in the program. For ® Al � rr • �j verification of certification for individual products, go to www.ahridirectory.org. ISO 9001 QMI-SAI Global i 12 PIMP. mximaps 'Irma* ampolum• r m '! ""m ■ ,,emir r Pie '.,""-11! 11.° —"—mi• 1110"00110 1111111111111 aromilli SII4'".. i - IF111101" "91.111 1111111Pin 11111"iii 3144c, �. f t •••■•■10_ imeas 1111 aft. MIMMOMIli Ilii` se