RECEIVED APR 13 2015 OF TIGARD STRUCTURAL CALCULATIO CITY N&G DIVISION FOR Replacement Mechanical Unit at 7155 SW Vannes St. Tigard, OR V 4,* F • y 7,738 9 � w A CITY OP TIGARD 'on Y r� REVIEWED FOR CODE COMPLIANCE 'EXPIRES: 6130//t0 7c;:vcd: [ [ ] Permit#: J4AE C 25- 2o2 Address: 7(- k/l i Suite#: l By: Date: �.12( 1(Jr OFFICE COPY ■IN • Project: Vannes Corner Bldg xvAC I STRUCTURAL Client: Bamess Controls Proj.No.: 15-155 Lim Date: 04/2015 By: MLV Sheet No.: 2700 SS HAR MSON ST.STS.B.MOLWAUXIE OR.97222,603-607-0481.FAX 603-607-0186.arttetkaasissara.com DESIGN SUMMARY THIS PROJECT CONSISTS OF REPLACING TWO EXISTING ROOF TOP MECHANICAL UNITS WITH TWO NEW UNITS. THE NEW UNITS WILL BE PLACE IN THE SAME LOCATION AS THE EXISTING UNITS. THE DIMENSIONS OF THE NEW UNITS ARE COMPERABLE TO THE EXISTING UNITS. THE EXISTING UNITS WEIGH 490 LBS,THE NEW UNITS WEITH 497 LBS. THE LOAD ON THE STRUCTURE DOES NOT CHANGE BECAUSE OF THE NEW UNITS. DESIGN LOAD CRITERIA SDS=0.722 SDI =0.444 ap= 1.0 Rp=2.5 SNOW LOAD=25 PSF DEAD LOAD= 15 PSF WIND— 120 MPH(ULTIMATE) EXPOSURE=B N ► '■ ■■�1, Project: Varnes Corner Bldg HVAC C■ III STRUCTURAL Client Bamess Controls Proj.No.: 15-155 ���,��ENGINEERS Date: 04/2015 By: MLV Sheet No.: SOMMNary 2700 SE HARRISON Sr.STE.RI.90LWAUROE ORI,97222,503-107-0451.PAR 503-607-0456 67M " RE PLAcr ENT UNITS ° NEw UNIrs ,iR : (oMPPRABa .3"Af e2A . AS fxz$ TJ^Y4 04.771f r2 ADD kl=cc ,8E PC ce O 42(Y .0 YTS TINS r wt _ 9 # ViAbk‘l������ E UNIT �/ d N OAP r Wf = 1497 ,,,66 drrt� fZ5 (20 3600 frt. lb zAv<REASe-= X90 = gm = , ,q, I`r'lb • t= = 99 300 Q 0 - 3.31 >/, !l .v►c ei/11Ic 10,9z __ NO kit Rte? Sas= ©1722 Op = /.0 OrA../0 g9 = 2.5 _ Fp - /25* ap 5 s Kip 1 5 Ecu z---- N. Co1N�S {p-- /zp /t 21-4 fp -_..Y 3/` 25 A/6) 67Z4 wp 0}2(4 : ,4r-,,4d Tv 4xq ■ /(i) ?8 '‘cRE W Co/NF .e a; 35Wp . S� f� TTAci4 qx(f re 7R')ss 13eZ04/ �--- /(f) s D we t s boo e, cower F ;,gyp _ ,d,i5 Wp 4?� Fp - , 25 (Y197)- IZ54k ■ ��INC. Project: Vames Corner Bldg HVAC ISTRUCTURAL Client: Harness Controls Proj.No.: 15-155 �� ENGINEERS Date: 04/2015 By: MLV Sheet No.: I 2700 SE HARRISON Sr.STE,H,MILWAUKIE OR.97222,503-507-0481,FAX 503-807-0488. m tteken ieeen.eom 42/2015 Design Maps Summary Report 7S Design Maps Summary Report User-Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 45.42509°N, 122.7513°W Site Soil Classification Site Class D - "Stiff Soil" I AIL Risk Category I/II/III t lYWA1 ✓ ws�'•vn Qr i I 1� Farmington 4 p o- Milwauki• o o Lake, swego 46 O o .. ••_ SGhoit6 a;- Q oKing City - 0 ham ; N 0 R TH r-cr,ks& T.: I tin A M E R I C A 0 mapq 205 SherwooR2•15 ; est Se m lttia 20 .:{ 0 Mapaeest USGS-Provided Output Ss = 0.976 g SM$ = 1.083 g Sew = 0.722 g S1 = 0.422 g Smi = 0.666 g Sun = 0.444 g For information on how the SS and Si values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions In the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP" building code reference document. MCER Response Spectrum Design Response Spectrum 0.99 1.10 0.90 o.» 0.72 0.99 0.64 0.77 0.56 S 0.66 1. 0.49 to 0.55 , 0.40 0.44 0.32 0.33 0.24 0.22 0.15 0.11 0.09 0.00 0.00 0.00 120 0.40 0.60 0.90 1.00 1.20 1.40 1.50 1.90 2.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.90 2.00 Period,T(sec) Period,T(sec) Although this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or implied,as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. Z httpl/ehp2 earthquake.wr.usgs.govhdesign mapatus/summary.php7ternplateaminimal ddatituden45.425088ddorgittxfri-122.7513048isitedass-3&iskcategorya0... 1/1 g 5 7" e7 UltA r PG/PGX - DATA AND SPECIFICATIONS PGOao1 _ 1 PG048150-18 PG04815O-3B PG048160J8 PGX060100-1A PGX060100-3A TotalCooling-BTUH 45000 45000 45000 ' 45000 57000 57000 Sens.Cooling-BTUH 36000 36000 35000 - 36000 43000 43000 Cooling CFM Nominal 1600 1600 1600 1600 2000 2000 SEER (2) 10.0 10.0 10.0 10.0 10 0 10.0 EER. (3) - - 9.3 9.3 93 Sound Rating(2) 8.4 8.4 8.4 8.4 B.4 8.4 Heating Input 115000 140000 140000 140000 92000 92000 Heating Capacity(1) 92000 112000 - - 73600 - Output Capacity - - 112000 112000 - 73600 AFUE(1) 78.0 78.0 - - 78.0 - Outdoor S.S.Eff. 80.0 80.0 - 80.0 Calif.SEER 72.8 72.0 72,0 72.0 71.3 71.3 Temp.Rise Ran ge 35-65 50-80 _50-80 50-80 Indoor Blower 25 55 25 55 Type DD DD I DD DD DD DD Size-DxW 10x10 10x10 10x10 10x10 11x10 11x10 MotorH:P. 12 . 12 1/2 1/2 3/4 y4 -E vaporator Coil Face Area (ft2) 4.43 4.43 4.43 4.43 4A3 4.43 Fin/In. i 13 13 * 13 13 13 13 No.of Rows 4 4 4 4 4 .. 4 Outdoor Fan Fan Dia.(In.) 22 22 22 22 22 22 Motor H.P. 1/4 1/4 1/4 1/4 1t3 1/3 Condenser Coil Face Area (ft=) 14.95 14.95 14.95 14.95 14.95 14.95 Fin/In. 19 19 19 19 19 19 No.of Rows 1 1 1 1 2 2 Electrical -' Ph 1 1 3 3 1 3 Volts 208/230 208/230 208230 460 208/230 208/230 Compr.RLA 21.8 21.8 11.9 5.9 26.9 16 0 Compr.LRA 105.0 105.0 130.0 65.0 135.0 137.0 indoor BlwFLA 4.2 4.2 4.2 1.4 6.0 8.0 OutdoorBlwFLA 1.6 1.6 1.6 0.8 . 2.4 2.4 Min.CircuitAmp. 33.1 33.1 20.7 9.6 42.0 28.4 I Max.Fuse Size 1 _ 50 -30 15 _ 60 40 1 NetWeight ` 490 500 500 . 500 525 525 Shipping Weight --- 500 540 ; _-510 510 535 I 535 J PGX Models meet California NOx Requirements (1)In accordance with D.Q E.Test Procedures (2)Certified per ARI 210 and 270 (3)BTU/Watt 4 80/67 F inside-95 F outside air 7 3 Al-51A-( vAILr hone SPI(IFKATIO*S SPEUIIWIONS-GPG1348-60 GPG1348 GPG1348 GPG1348 GPG334)GPG1343 1 PG1348 6PG1360 GPG1360 GP61360 070M411' 090M41D" D9041 • 115M410•l 115M41E• 090M41D• 115M410• 140M41D• r COouNG CAPACITY Total 8TU/h 46,000 46,000 46,000 46,000 46,000 46,000 57,000 57,000 57,000 Sensible 8TU/h 36,700 36,700 36,700 36,700 36,700 36,700 43,800 43,800 43,800 SEER/EER 13.0/11.0 13.0/11.0 13.0/11.0 13.0/11.0 13.0/11.0 13.0/11.0 13.0/10.75 13.0/10.75 13.0/1075 Decibels 80 80 80 80 80 8O 80 Bo 80 AHRI Reference as 5677931 6531560 5677932 6531560 -. 5677932 6531560 5677892 5677892 5677892 HEATING CAPACITY Input 8TU/h 69,000 69,000 92,000 92,000 115,000 115,000 92,000 115.000 138,000 Output 811)/h 55.000 55,000 73,600 73,600 92.000 92,000 73,600 92,000 110.400 AFUE 80 80 80 BO BO BO 80 80 80 Temperature Rise Range 35-65 35-65 45-75 45•75 45-75 45-75 45-75 45-75 45.75 No.of Burners 3 3 4 4 5 5 4 5 6 Orifice Size(Natural/Propane) 43/55 .43/55 43/55 43/55 43/55 43/55 43/55 43/55 43/55 EVAPORATOR MOTOR Type EEM EEM EGM- EEM EEM EEM EEM EEM EEM Wheel(DxW) 11'x10" 11"x10" 11"x10" 11"x10" 11'x10' 11"x10' 11"x10" 11"x10' 11"x10" Indoor Nominal CFM 1,550 1,550 1,550 1,550 1,550 1,550 1,750 1,750 1,750 Motor Speed Tap(Cooling) T4 14 14 14 , 14 74 T4 T4 T4 RPM/Amps(Cooling), 1.050/5.8 1,050/5.8 1,050/5.8 1,050/5.8 1,050/5.8 1,050/5.8 1,050/7.6 1,050/7.6 1,050/7.6 Horsepower 3/4 3/4 3/4 3/4 3/4 3/4 1.0 1.0 1 0 EVAPORATOR Colt Face Area MI) 5.67 5.67 5.67 5.67 5 6/ 5.67 5.67 5.67 5.67 Rows Deep/Fins per Inch 4/14 4/14 4/14 4/14 4/14 4/14 4/14 4/14 4/14 Piston Size/Cooling/ 0.076 0.076 0.076 0.076 0.076 0.076 0,086 0-086 0.086 Fitter Size(H') 5.1 5.1 5.1 5.1 5.1 5.1 6.3 6.3 6.3 Drain Six OPT) X" X" %' X' X" yl" y," X, X.. Refrigerant Charge(oz.) 87 99 87 99 87 99 91 91 91 CONOEatsra FAN/Cat Horsepower RPM 1/4-1100 1/4.1100 1/4.1100 1/4-1100 1/4-1100 1/4•1100 1/4-1100 1/4-1100 1/4•1100 Diameter/a of Blades 22'/3 22"/3 22"/3 22"/3 22"/-3 22"/3 22"/3 22"/3 22"/3 Outdoor Nominal CFM 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 Face Area(tt') 8.8 15.4 8.8 15.4 8.8 15.4 11.32 12.32 13 32 Rows Deep/Fins per Inch • 2/27 1/24 2/27 1/24 2/27 1/24 2/27 2/28 2/29 COMPRESSOR 1 Quantity/Type 3/Scrofl 1/Scroll 1/Scroll I/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll Stage Single Single Single Single Single Single Single Single Single Compressor R A/IRA 19.9/109 19.9/109 i 19.9/109 19.9/109 19.9/109 19.9/109 26.4/134 26A/134 26.4/134 ELECTRICAL DATA r Voltage•Phase(60 Hl) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Indoor Blower FLA./I.RA 5.8 5.8 5.8 5.8 5.8 5.8 7.6 7.6 7.6 Outdoor Fan FIA/LRA 1.4/2.9 1.4/2.9 1.4/2 9 1.4/2 9 1.4/2.9 1.4/2.9 1 4/2.9 1 4/2.9 1.4/2.9 Total Unit Amps 27.1 27.1 27.1 27.1 27.1 27.1 35.4 35.4 35.4 Min.Circuit Ampacity 32.1 32.1 32.1 321 32.1 32.1 42 42 42 Max.Overcurrent Protection 50 amps 50 amps 50 amps 50 amps 50 amps 50 amps 60 amps 60 amps 60 amps Entrance Six Power Supply 1Si" 134" 134' 1)4" 1%" 1X" 1%" 1%" 1%" Entrance Size Control Voltage X' ti" X' %' - %" 31" %. %. Operating/Ship Weights(Ibs) 1 464/487 518/540 464/492 523/545 ,464 497 '528/550 466/495 _ 466/500 466/505 ' Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sites. • ' Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Note:Always check the 5&R plate for electrical data on the unit being installed. 55•GPG13M www.goodmanmfg-com 5 "l NEW PRODUCT DIMENSIONS UNIT DIMENSIONS /t7/. ^11````1 31 �� FLUE EXHAUST 1ST B �`_ - FLUE EXHAUST 16//, I A..:........„! 40..., ' �~`/� 1 31B 6 M'/ \� 16� SUCTION/LOOM PRESSURE PORTS 1 16!16 ! i B SEMND COMPRESSOR ACCESS PANEL \ ✓ • :.\ I /i may' 5 yt �: COMBUSTION AIR INTAKE \ `�- B RETURN HEAT EXCHANGE ACCESS PANEL ` .` �/ OAS SUPPLY ENTRANCE ‘:::ilk 1 ./' CONDENSATE ORNNCONNECTION ` SUPPLY 311'NPT FEMALE 6 to EYAPORATOIUCONTROL PANEL ACCESS PANEL 191/6 0* s*"....... Lr , ,tul1• i 'k!'i,J DIMENSION � • /� 1 (INCHES) MEDIUM{ LARGE A 32 ID ` S 16 /6 y / C 9112 14 POWER WIRE ENTRANCE '' '■,e' ''' l , -41. CONTROL WIVE ENTRANCE 11, EXHAUST FLUE HOOD td. l� �/ BLOWER ACCESS PANEL AR INTAKE MEDIUM CHASSIS '='' \. O '''''N.:\.,.,.�LARGE CHASSIS ,/ J SUPPLY RETURN 7 me-04 4UuXT y CE) o°P ' o 5�5Tt�1 SDW�15b60 Eft To -muss ist-tow TYa ////NN:\k Z./ • R F TR O S 5@.2i4'o/G ��R�O PR(hcF`�o la 707 • OP.EGO: 'VC o9. 2-(fr �� tEON VAltiat !EXPIRES: 8/30/ /6 J INC• Project: Vames Corner Bldg BVAC STRUCTURAL Client: Harness Controls Proj.No.: 15-155 ���� ENGINEERS Date: 04/2015 By: MLV Sheet No.: 2700 S6 HARRISON ST.SM.B,1®.WAUKIE OR.97222,503-607-0481.PAX 503-607-0486. > blom�neers eom r PRODUCT DIMENSIONS UNIT DIMENSIONS 13AZ (oits'r �•,� FLUE EXHAUST I NOS i1S7 S \� FLUE EXHAUST / 16 �'I A 1 SIB S 1/2 SUCTIONA.b1X0 PRESSURE PORTS B BEHIND COMPRESSOR ACCESS PANEL r• \ 1.�� 2 y/ 16'..- ..-,I . „.„:„...„...„ � .1,4 . / COMBUBTWNAIRIMAKE -1 \ � B / RETURN NEAT EXCHANGE ACCESS PANEL � I 44.GAS SUPPLY ENTRANCE �b,�' CONDENSATE DRAIN CONNECTION- SUPPLY 3l4 NPT FEMALE \' BIA EVAPORATORICONTROL PANEL ACCESS PANEL 191A \ Dpp 7 16 \ ��I ,1y�,,/• ••; , 6};� DIMENSION 1 / i 7 A pNCNESI MEDIUM LARGE I, 1 A 32 40 B 1E 1 ••Is C 9v2 u I' -POWER WIRE ENTRANCE - - • �� I CONTROL WIPE ENTRANCE IS ) EXHAUST FLUE HOOD s• y`\ q • \ SLOWER ACCESS PANEL �� COMBUSTION -I AR BRAKE / ! I 3/H \:� ! , MEDIUM CHASSIS \ *P G1324, ` /-'-- -i V LARGE CHASSIS \\ -• . *PG1342, 48, 60 1 'p -\ J 8UPPLY RETURN � "1 J7 N v 6c,ob,.1N L. 791,1 '' vGG-/ 74 / 16.ctf/2S- 189 . / '>. f / / ,/''./ 1 Tr 2_ , / / . j Bno,..rN4 LUr / ,, C/ vf STAGE AAEA 1/42N5 CoAA.-.1,1 /r6/7w4/. Oft) 7'Z22 3