Loading...
Report 59SC5A • Comfort'' Series Single—Stage 4—Way Multipoise Carrier Condensing Gas Furnace Series 100 iurn tO 111c cxpur1 Product Data RECEIVE' \_* ��- enough for taller coils,but still allows enough room for service. • Silicon Nitride Power Heat" Hot Surface IgnitAPR 1 3 2015 • Aluminized-steel primary heat exchanger. ,�T t' • Stainless-steel condensing secondary heat eietlall F TIGARb O • High-quality corrosion-resistant prepaintSM >N'DMS1G� hemmed edges for safety. ' • Factory-configured ready for upflow applications. • Direct-vent/sealed combustion,single-pipe venting or ventilated o cil combustion air. V • PSC blower motor,single-speed inducer motor,and single-stage 91' gas valve. I • Self-diagnostics with SuperBrite LED • Approved for Twinning applications(60-14 through 120-60 sizes,only). • Propane convertible(See accessory list). • Approved for Manufactured Housing/Mobile Home applications (except 140,000 Btuh input)with MH accessory kit. Al 1263 • Convenient Air Purifier and Humidifier connections. The 59SC5 Multipoise Comfort Series Condensing Gas Furnace • Residential installations may be eligible for consumer financing features energy efficiency of 95.5% AFUE gas efficiency and workhorse PSC blower motor. This gas furnace also features through the Retail Credit Program. 4-way multipoise installation flexibility, and is available in nine • Certified to leak 2%or less of nominal air conditioning CFM model sizes. The 59SC5 can be vented for direct vent/two-pipe, delivered when pressurized to 1-in.water column with all ventilated combustion air, or single-pipe applications. All units present air inlets,air outlets,and condensate drain port(s)sealed. meet California Air Quality Management District emission requirements, are design certified in Canada, and are certified for mobile/manufactured home use. LIMITED WARRANTY* • 10 year parts and lifetime heat exchanger limited warranty to the STANDARD FEATURES original purchaser upon timely registration. • 4-way multipoise design for upflow,downflow or horizontal • Limited warranty period is five years for parts and twenty years installation. for the heat exchanger if not registered within 90 days of • Installation flexibility with a 360-degree rotating elbow. installation.t • More than twelve different venting options,including optional *For owner occupied,residential applications. through-the-cabinet downflow and horizontal venting. tJurisdictions where warranty benefits cannot be conditioned on registra- tion will receive registered limited warranty benefits. • Ideal condensing furnace height 35"(889 mm)cabinet:short • OE51 GiV CER REU.Comfort I A . SERIES 160 �FRTIo'<D® <eanrieD U 1 SPECIFICATIONS Heating Capacity and Efficiency 040-10 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20 Input High p Heat (BTUH) 40,000 60.000 60.000 80.000 80.000 100,000 100,000 120,000 140,000 Output High (BTUH) 39,000 58,000 58,000 78,000 78.000 97,000 97,000 117,000 135.000 Efficiency AFUE%(ICS) 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5 Certified Temperature High Heat 40-70 40-70 40-70 40-70 40-70 40-70 40-70 40-70 45-75 Rise Range °F(°C) (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) (25-42) Airflow Capacity and Blower Data 040-10 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20 Certified External Static Heating 0.10 0.12 0.12 0.15 0.15 0.20 0.20 0.20 0.20 Pressure(in.w.c.) Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Airflow Delivery @ Rated ESP(CFM) High Heat 820 840 980 1040 1500 1565 1520 2210 2190 Cooling 905 1130 1420 1600 2025 1565 2145 2065 2100 Cooling Capacity(tons) CFM/ton 2 2.5 3.5 4 5 4 5 5 5 @ 400,350 CFM/ton CFM/ton 2.5 3 4 4.5 5.5 4.5 6 6 6 Q - - In Direct-Drive Motor Type Permanent Split Capacitor(PSC) Direct-Drive Motor HP 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 CI) Qt Motor Full Load Amps 6.2 6.2 6.8 7.9 13.8 6.5 13.8 14.1 14.1 Li) RPM Range 500-1150 Speed Selections 4 4 5 5 5 5 5 5 5 Blower WheelDiaxWidth -I in. 11x7 11x7 + 11x8 11x8 11x10 11x10 11x101 11x11 11x11 Air Filtration System Field Supplied Filter Used for Certified Watt Data KGAWF1606UFR I KGAWF1306UFR I KGAWF1406UFR I KGAWF1506UFR Electrical Data 040-10 1 060-10 1 060-14 1 080-16 1 080-20 1 100-14 1 100-20 1 120-20 1 140-20 Input Voltage I Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Input Amps Amps 6.8 7.0 8.4 9.6 14.5 7.6 14.6 14.9 14.9 Unit Ampacity Amps 9.5 9.7 11.5 13.0 19.1 10.4 19.2 19.6 19.6 Minimum Wire Size AWG 14 14 14 14 12 14 12 12 12 - Maximum Wire Length Feet 39 38 32 28 30 35 29 29 29 @ Minimum Wire Size (M) (11.9) (11.6) (9.8) (8.5) (9.1) (10.7) (8.8) (8.8) (8.8) - Maximum Fuse/Ckt Bkr Amps 15 15 15 15 20 15 20 20 20 (Time-Delay Type Recommended) Transformer Capacity(24vac output) 40 VA External Control Power Available Heating 27.9 VA Cooling 34.6 VA Controls - 040-10 1 060-10 I 060-14 1 080-16 1 080-20 I 100-14 1 100-20 I 120-20 I 140-20 Gas Connection Size 1/2"-NPT Burners(Monoport) 2 I 3 I 3 I 4 I 4 1 5 I 5 I 6 I 7 Gas Valve(Redundant) I Manufacturer White Rogers - Minimum Inlet Gas pressure(in.wc) 4.5 Maximum Inlet Gas pressure(in.wc) 13.6 Gas Conversion Kit-Natural to Propane KGANP50011 SP Gas Conversion Kit-Propane to Natural KGAPN42011 SP Manufactured(Mobile)Home Kit KGAMH0601KIT I N/A Ignition Device Silicon Nitride Limit Control 165 I 165 I 180 I 170 _I 200 I 180 I 180 I 160 I 155 Heating Blower Control(Heating Off-Delay) Adjustable:90,120,150.180 seconds Cooling Blower Control(Time Delay Relay) 90 seconds Communication System none Thermostat Connections Corn 24V,R,W.G,Y Accessory Connections EAC(115vac);HUM(24vac) 3 MODEL NUMBER NOMENCLATURE 1-2 3 4 5 6 7-9 10 11-12 13 14 15-18 Family Htg.Stages Tier Eft; Major Se-,es ■-0g Cap Motor Width Voltage Minor Series Airflow 59 5 C s A 040 S 14 -- – 10 08-800 CFM Family) 10-1000 CFM S-Single Stage 12-1200 CFM T-Two Stage 14-1400 CFM M-Modulating 16-1600 CFM C-Comfort 16-1800 CFM P-Performance 20-2000 CFM N-Infinity 14-14.2" 22-2200 CFM 0–90 AFUE 17-17.5" Minor Series 3–93 AFUE 21-21.0" 5–95 AFUE 040>=40,000 BTU 24-24.5" 6-96 AFUE 060=60.000 BTU S-Standard 7-97 AFUE 0880=60,000 BTU E-Energy Efficient 100=100,000 BTU V-Variable Speed 120=120,000 BTU. Major Series 140=140.000 BTU Not all familes have these models. A12037 in FURNACE COMPONENTS HOT SURFACE CT) IGNITER II) BURNER MANUAL RESET \ ROLLOUT SWITCH FLAME It �w� w� :/.f:_ SENSOR—_._. li I I, /III �RESET li, Il. 1 ri ' % • ■ ROLLOUT SWITCH iv 1 J GAS VALVE - � ��. 4 I ���� MAIN LIMIT SWITCH .1 IIIII .,11111 , (BEHIND GAS VALVE) OPERATING INSTRUCTIONS l [1! r NOT SHOWN(LOCATED ON / MAIN FURNACE DOOR,SEE OPERATING INSTRUCTIONS 1 ' — •mi/l' lici • ���I�'INSIDE DOOR FIGURE). ---- �/////jj�_ INDUCER MOTOR ,I 1 l� �,/ f-� /IC ASSEMBLY ELECTRICAL JUNCTION % G� \\�_///�„—; ,�• . , BOX(IF REQUIRED, 14�r.DWI I YY� LOCATION MAY VARY) ll� tt.i�-t. `�i%� BLOWER DOOR__ �J7 /!' .• SAFETY SWITCH ✓ IV gi f---MEDIA CABINET Ij i. ■ FURNACE , -- BLOWER AND CONTROL — ' Mil ' _ MOTOR BOARD -®0 IIWA _ CAPACITOR/ )11 POWER CHOKE { (IF USED) RATING PLATE NOT SHOWN \ (LOCATED ON BLOWER DOOR) t - ----- ---- _ REPRESENTATIVE DRAWING ONLY,SOME MODELS MAY VARY IN APPEARANCE. A11408 4 • 59SCSA FURNACE SIZE A B C D SHIPPING (MODELS) (CABINET WIDTH) (OUTLET WIDTH) (BOTTOM INLET WIDTH) WEIGHT (59SC5) inches mm Inches mm Inches mm Inches mm LBS KG 040-10 123.0 55.4 ' 14 3/16 361 121/2 319 12 9/16 322 71/8 181 060-10 127.0 57.2 060-14 e isii 171/2 445 15 7/8 403 18 406 8 3/4 222 144.0 64.8 nano _ 080-16 154.0 69.3 4144 ISSN I I 181 8 72 7 100-14 21 889 19818 482 19112 I 496 101/2 287 188.6 75.8 ma Pan ., MIT 100-20 1 168 5 75.8 �� 120,20 186.0 83.7 24112 622 22 718 581 23 584 12114 311 03 ° 140 20 190.0 86.5 NR r7•21 NURE . 29 1/2- a 11/18 17{9.31 1170.11 2934 -- 167a.11 17ao.s1 d 2611n8 ••• 28 381 �. `• 28 76.11 - - -+ 7 ]170.0] 1979.1 j a n 6... 1 � � so 5n6 22 7/18 IKEA .. 56.0] CA 121 191 O 20 681 1...----A 535.81 152271 1565.81 1{86 eJ I OUTLET YAM 20 577 p ? 0/63. �..I UAIN IIfTAKE 0 0 81,/81 AIR 130W 01 al{ /r pp44..pp 115.811_ MI RDW ":3- AIR FLOW I't/� 4 i }� 11.08OONN r`' __ AIR INTO 111' 131{ V AIi1 i I �! CONDENSATE ORAtN TRAP 7!I 09 I I , GAS 1 LOCATION ' 001.61 VENT 1 0a -- ��1 4, IIPi r P221 I .. (078 71& n� 2181 ' THERMOSTAT ENTRY THERMOSTAT ENTRY 12151 I I 1 I I i� Ip'6I I �• Qi781-�� I 1 WA POWER CONN I as aHa as se D ® 0 i6 y I • Il�� 07/1 122.2] ! f�M 186361 122.21 POWER CONN -------- ` I f I 2/148 ® I I .z Ne6•M ao 7/78 a�SIDE INLET � 1,111 VA 237na g7aeq R>a'� I7II0'{1 -0781SIOEINLET �`'13221 I t leans 161a•q l •N as 2e 5A 24 07R '21 i 1,106] m81n 160e.7J + 12.21 141WNe 176118 s216n6 ?D 1M P76•al 118es1 Nee?•e1 • 1613.9]161/19 /Sane 1{64.6] 142114 1 l 1 I_ _ HiL L_ _ ___41 117.61 BOTTOM RETURN 117.81 {] WI 1664.31 WIDTHS 23316 1592.01 21 288ne /534.01 NOTE ALL DIMENSIONS IN INCH NMI [666.6] a' .. 285/16 leee.el .„ 505024-a 510 °`" C ral I - w 24ABB3 Comfort' 13 Air Conditioner with Purono Refrigerant Carrier 1 -1/2 to 5 Nominal Tons turn to the expert Product Data INDUSTRY LEADING FEATURES/ BENEFITS Efficiency • 13.0 - 13.2 SEER/10.8- 11.0 EER (based on tested combinations) '11' i j i II f' • Microtuhe Technology"e refrigeration system �.��'���1 II', 1 r �I I II',", • Indoor air quality accessories available Sound!---. ' • Sound level as low as 75 dBA _`r • Sound level as low as 74 dBA with accessory sound III''., blanket �' r1 Comfort a�11 Al u System supports Edge© Thermidistat"' or standard yn��i thermostat controls A 11iigli Reliability PI • Puron® refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime servce cost. Comfort • Scroll compressor Nixon. SERIES • Internal pressure relief valve Me enwwcoment.11y sound reIngemn, • Internal thermal overload • Filter drier Carrier's Air Conditioners with Puron© refrigerant provide a collection of features unmatched by any other family of • Balanced refrigeration system for maximum reliability equipment. The 24ABB has been designed utilizing Carrier's Durability Puron refrigerant. The environmentally sound refrigerant allows WeatherArmor" protection package: you to make a responsible decision in the protection of the earth's ozone layer. • Solid,durable sheet metal construction This product has been designed and manufactured to meet • Dense wire coil guard available Energy Star® criteria for energy efficiency when matched with (3-phase units come standard with dense wire coil appropriate coil components. Refer to the combination ratings in guard) the Product Data for system combinations that meet Energy Star® • Baked-on,complete outer coverage, powder paint guidelines. Applications NOTE: Ratings contained in this document are subject to • Long-line - up to 250 feet (76.20 m) total equivalent change at any time. Always refer to the AHRI directory length, up to 200 feet (60.96 m) condenser above (www.ahridirectory.org) for the most up-to-date ratings evaporator,or up to 80 ft. (24.38 m)evaporator above information. condenser(See Longline Guide for more information.) • Low ambient (down to -20°F/-28.9°C)) with accessory kit MODEL NUMBER NOMENCLATURE • 1 2 3 4 5 6 7 8 9 10 11 12 13 N N A A A/N N N N A/N A/N A/N N N 2 4 A B 8 3 3 6 A 0 0 3 0 Product Product Tier Major SEER Cooling Variations Open Open Voltage Series Series Family Series Capacity 3=208/230-1 1.000 Btuh A=Dense Grille 0=Not 0=Not 5=208/230-3 0= 24=AC A=RES AC B=Comfort B=Puron 3=13 SEER (nominal) W—Wide Grille Defined Defined 6=480(3 Original 1 =575/3 Series (c) E IM PF7AMEN CERTIFIED.. �, Puron ....ar,a,r.rr.,r.r. c us the environmentally sound refrigerant Use of the AHRI Certified CD TM Mark indicates a el ENERGY STAR m manufacturer's ..+ CO participation in the ■ This product has been designed and manufactured to rQ program For verification V Al meet Energy Star®criteria for energy efficiency when 7 of certification for individual matched with appropriate coil components. However. C ISO 9Q01 proper refrigerant charge and proper air Sow are criecal products,go t0 to achieve rated capacity and efficiency.Installation of www.ahrldlrectory.org. this product should follow all manufacturing refrigerant QMI-SAI Global charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES • Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X Maximum SEER 14.50 14.25 15.0 14.0 14.0 14.0 13.5 Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Dense Grille(standard on 3—Phase only) X X X X X X=Standard • 2 , PHYSICAL DATA UNIT SIZE SERIES 18-32 24-31 30-31,51 36-31,51, 42-30,50,6 48-91,61,61,1 60-32 60-52,82,1 • 61,11 0 1 2 Operating Weight lb(kg) 107 110 111 141 190 186 190 215 (48.5) (50.0) (50.3) (84.0) (88.2) (84.4) (88.2) (97.5) Shipping Weight lb(kg) 130 134 138 170 218 224 228 250 (80.0) (60.8) (61.7) (77.1) (98.9) (101.6) (102.5) (113.4) Compressor Type Scroll REFRIGERANT Puronp(R-410A) Control TXV(Puronfl Hard Shutoff) Charge lb(kg) 3.50 3.80 4.10 5.34 5.84 7.00 8.19 8.00 (1.6) (1.7) (1.9) (2.4) (2.7) (3.2) (3.7) (3.8) COND FAN Propeller Type,Direct Drive Air Discharge Vertical Air Qty(CFM) 1792 2218 2218 2954 3187 3385 3385 3385 Motor HP 1/12 1/10 1/10 1/4 1/5 I 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1100 1100 800 - 1100 COND COIL Face Area(Sq ft) 8.40 8,40 9.80 13.13 17.25 19.40 12.93 15.09 Fins per In. 20 25 25 25 25 25 20 20 r7 Rows 1 1 I 1 1 1 1 2 2 m Circuits 3 3 3 3 4 5 5 6 m Q VALVE CONNECT.(In.ID) •t Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 N Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 REFRIGERANT TUBES*(In. OD) Rated Vapor* 3/4 7/8 1-1/8 Max Liquid Unet 3/8 *Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. 1 See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 3 24ABB3 DIMENSIONS - ENGLISH INT SERES ELECTRICAL A B C 0 E F G K L M N P OPERATNG SFlP ' SIPPING CHARACTERISTIC5 WEIGHT (Ws) WEIGHT Ilbs) DGIENSIONS IL x IN x H) 24988318 2 X 0 0 0 23 1/8' 25 5/16" 3 3/4" 3/4' 4 7/16' 18 1116' 7 13/16' 2 13/16' 1/2' 16 1/2" 15' 12' 107 130 24 1/4" X 27 3/8' X 33 1/2' 24488324 1 X 0 0 0 23 1/8' 25 5/16• 3 314• 3/4" 4 7/16" 18 1/16' 7 13/16• 2 13/16' 1/2' 16 Ill" 15" 12' 110 131 24 1/4" X 27 3/8' X 33 1/2' 24988330 1 X 0 I 0 23 1/8' 28 11/16' 3 3/4" 3/4' 4 7/16' 18 1/16" 7 13/16" 2 13/16' 112' 16 1/2" 15" 14' 111 136 24 1/4" X 21 3/8' X 33 1/2' 24688336 1 X X X X 25 3/4" 32 5/16' 3 7/8' 7/8" 4 7116" 21 I/4' 9 1/8' 2 15/16• 5/8" 14 1/4' 10 1/2" 16" 141 170 26 7/8' X 30 I/16" X 35 15/16' 24668342 0 X 0 X X 31 3/16' 32 5/16' 3 7/8" 7/8' 6 9/16' 24 II/16' 9 I/8' 2 15/16' 5/8" 15 3/4" 16 1/4" 13 3/4' 190 218 32 3/8' X 35 1/0" X 35 15/16' 24688348 1 X X X X 31 3/16• 35 3/4" 3 7/8' 7/8' 6 1/16' 24 11/16' 9 1/8' 2 15/16' 5/8' 16 3/8" 15 3/8" 15 1/4• ^ 186 - 224 32 3/8' X 35 1/2" X 39 3/8" 24606360 2 X 0 0 0 31 3/16• 25 1/2" 3 718• 718" 6 9/16' 21 11/16' 9 1/8" 2 15/16' 5/8• 14 1/8' 15 3/8' 11 318• 190 226 32 3/8' X 35 1/2" X 32 9/16" 24988360 2 0 X X X 31 3/16' 28 15/16' 3 7/8' 7/8' 6 9/16' 24 11/16' 9 1/8' 2 15/16• 518' 16" 15 1/2" 12 3/4' 198 230 32 3/8" X 35 1/2" X 32 9/16' o a NOTES 44 4Q o X = YES 1. ALLOW 24"CLEARANCE TO SERVICE END OF UNIT o ID • 4-,'X 0 - NO 48"ABOVE UNIT. 6"ON ONE SIDE, 12"ON REMAINING SIDE ry Li 4 AND 18"BETWEEN UNITS FOR PROPER AIRFLOW. p o el- 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING EN N MODE IS 55°F.MAX.125`F 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY el A 5. ALL DIMENSIONS ARE IN INCHES'UNLESS NOTED. SO M AIR IN AIR DISCHARGE AIR DISCHARGE G im.imovii\______, \ 1 / o B FIELD CONTROL I Isr \t1 SUPPLY CONK.01/8" HOLE 0 FIELD POWER SUPPLY CONN. " tqL 7/8' NOLE MYTH F - R IN /8' KNKOUT 03/8' ,, N LIQUID LINE CONN. • P • A 1• 4J' I __ 1 718" + 1_ _ 1 1 I 0)VAPOR LINE CONN. L 5/16' K 1,1, 03/8" TIEDOWN KNOCKOUT UNIT SIZE MOUNTING PAD 121 PLACES DIMENSIONS 18,24,30 23 1/2' X 23 1/2" 36 26" X 26' 48,60 31 1/2" X 31 1/2" 35" X 35"