Report APPLICABLE CODES: CITY OF PORTLAND, OREGON FIRE RESISTIVE REQUIREMENTS (CHAPTER 6, TABLE 601) MEANS OF EGRESS (CHAPTER 10) BUILDING CODE 2010 OREGON STRUCTURAL SPECIALTY CODE (OSSC) STRUCTURAL FRAME 1 HR OCCUPANT LOAD: 240 CALCULATED <20 ACTUAL v MECHANICAL CODE 2010 OREGON MECHANICAL SPECIALTY CODE (OMSC) EXTERIOR BEARING WALLS 1 HR MIN. REQUIRED EXITS: 2 EXISTING: 2 FROM PROJECT AREA >5 FOR WHOLE BLDG RECEIVED FIRE CODE 2010 OREGON FIRE CODE (OFC) INTERIOR BEARING WALLS 1 HR TRAVEL DISTANCE 250 FT ALLOWED; 155 FT IN PROJECT AREA PLUMBING CODE 2011 OREGON PWMBING SPECIALTY CODE (OPSC) EXTERIOR NONBEARING 0 HR(DISTANCE > 30' PER TABLE 602) COMMON PATH OF TRAVEL 100 FT (OSSC 1014.3.1) i,\:v 2 1 2012 ELECTRICAL CODE 2011 OREGON ELECTRICAL SPECIALTY CODE (OESC) INTERIOR NONBEARING 0 HR 2 WALLS OF TIGARD ACCESSIBILITY 2010 OREGON STRUCTURAL SPECIALTY CODE, CHAPTER 11 FLOOR CONSTRUCTION 0 HR SLAB ON GRADE �•'[+'�� ENERGY CODE 2010 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC) ROOF CONSTRUCTION 1 HR BUILDING NOTES: L�1 FIRE PROTECTION (CHAPTER 9) CONSTRUCTION (CHAPTER 6, TABLE 601) FIRE SPRINKLERS BUILDING IS FULLY SPRINKLERED AT 0.2 GPM/1500 TYPE: II-A ENERGY CODE OCCUPANCY (CHAPTER 3) NOT APPLICABLE B OFFICE AND ADMINISTRATION AREA F-1 MIXED WASTE PLASTICS, OIL RECLAMATION AREA ACCESSIBILITY PER CHAPTER 11-NO CHANGE TO EXISTING ALLOWABLE HEIGHTS AND AREAS (CHAPTER 5, TABLE 503) ALLOWED HEIGHT/AREA EXISTING HEIGHT/AREA OCCUPANCY B 5 STORIES/37,500 SQ FT 2 STORIES/1,890 SQ FT OCCUPANCY Fl 4 STORIES/25,000 SO FT 2 STORIES/24,030 SQ FT 'R. 6 t 3 in Engineering Design Narrative a J u Agilyx Corp is requesting permits for retooling their current process at the 7904 Hunziker Street, Tigord OR facility. The change is to install more efficient mechanical equipment. I There are two primary pieces of the new equipment both will require approved anchorage. The CSS Generation 5 foundation design and structural calculations are included here. The PRU Generation 6 foundations and calculations a will be covered under a deferred submittal. Building envelope does not change, no changes to type of construction. N For purposes of the permit process a Life Safety plan is provided showing reconfigured exit routes. A brief code N analysis is provided showing minimal change from the previous permit of Sept. 2009. o There will be use of city water in the process requiring a backflow preventer. Na other plumbing changes will be made. -c Electrical work will be required for the changes and will be submitted for city approval under a separate application. i No site work will be performed as part of this project. All permit work is taking place inside the building. The building or building mechanical systems ore not altered with this project. e601 Z_ 00'133 The existing fire sprinkler system will not be altered. The current sprinkler drawings can be found on file with the �^( 012,_ r9_64905 r9_64905 city. - a No system will be modified that is covered by the energy code. N y J 0 * C C J E E N 1 ISSUED FOR PERMIT,ADDED NARRATIVE BIP 11/20/201 0 ISSUED FOR PERMIT ISK 11/15/11 -1 I - 1 • EVERGREEN ENGINEERING »aw. THIS DRAWING IS CONSIDERED i I EnBInRnp and Can.hueNOn S.Men 2326.7 CONFIDENTIAL AND PROPRIETARY, u]SEERS IS N EMIL w COMMUNICATION TO OTHERS IS 0•0 u.-.m Oft A'I " PROHIBITED WITHOUT THE WRITTEN o `-. -_.--� PM CONSENT WITHOUT THE N awe arc 10000-02 �r o a[:1000G-02.dwg ^a• I ISSUED FOR a ligH D 11/6/12 AGIHZ-1000G02 y N o ' I CODE REVIEW 1 PERMIT AGILV%PRO ECTNUMBEi AGIF� CUSTOMER: AGILYX LOCATION: HUNIIKER I CUSTOMER PROJECT D. EVEREST ISK 1 Of 1 „••