Specifications
8n8 a ,0 I FIRE EQUIPMENT SYMBOL LIST SCOPE OF WORK mse L'S SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT E," ADD TENANT NOTIFICATION TO AN ADDRESSABLE x o FACP FIRE ALARM CONTROL PANEL SILENT KNIGHT EXISTING EXISTING CENTRAL STATION FIRE ALARM SYSTEM g 5820XL WHICH INCLUDES CENTRAL STATION OFF-SITE REPORTING, HORN/STROBES, AND STROBES. N — 2 PHOTOELECTRIC DETECTOR IN BASE SILENT KNIGHT EXISTING CEILING MOUNT SD505-APS E rl HORN STROBE - CEILING MOUNT, WHITE GENTEX SINGLE-GANG, 2-GANG, OR Og C GENERAL NOTES *or 1 (NAC, AND CANDELA NOTED AT DEVICE) GCC24CW DOUBLE WORKBOX CEILING MOUNT HORN STROBE - WALL MOUNT, WHITE GENTEX SINGLE-GANG, 2-GANG, OR 80" MIN TO LENS BOTTOM AFF MI (NAC, AND CANDELA NOTED AT DEVICE) CEC3-24WW DOUBLE WORKBOX 96" MAX TO TOP OF LENS AVE 6 ft�` " MIN TOP OF LENS TO CEILING 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA � STROBE - WALL MOUNT, WHITE GENTEX SINGLE-GANG, 2-GANG, OR 80' MIN TO LENS BOTTOM AFF 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 1=hr (NAC AND CANDELA NOTED AT DEVICE) GES3-24WW DOUBLE WORKBOX 96" MAX TO TOP OF LENS AFF 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE 1 -it lit 6" MIN TOP OF LENS TO CEILING THAN ONE FLOOR SHALL BE RISER RATED. 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTNING PROTECTION DEVICES. 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED. NOTIFICATION CIRCUIT SCHEDULE/ VOLTAGE D R 0 P CA LC U LA T I 0 N S 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS i T 'FIRE ALARM CIRCUIT". 1— CKT # DEVICE LOCATION / AREA O FY RCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT t 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP X (NFPA 72). 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION N-1 HORN/STROBES, STROBES EXISTING FACP EXIST EXIST 14 EXIST EXIST YES EXIST p:94E<fr61*--\°4 THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). CL N-2 HORN/STROBES, STROBES EXISTING FACP EXIST EXIST 14 EXIST EXIST _ YES EXIST , F 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR w T THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH N-3 HORN/STROBES, STROBES 1ST FLOOR NW TI AND HALL FACP 0.651 515 14 2.06 18.34 YES 10.09 �( I— • N-4 HORN/STROBES, STROBES SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00 � SECTION 14.6.2.4 (NFPA 72).1114 -- 2). Z • N-5 HORN/STROBES, STROBES EXISTING FACP EXIST EXIST 14 EXIST EXIST YES EXIST (ljf:" LLJ N-6 HORN/STROBES, STROBES EXISTING FACP EXIST EXIST 14 EXIST EXIST YES EXIST CITY OF TIGARD U REVIEWED FOR CODE COMPLIANCE wN) FIRE ALARM OPERATIONAL MATRIX Approved: [ L]— � np. cL NO CHANGES OTC: [ ] < ° z < S I T Eperm3t th F% 10 t6-11.0." ¢ ° w .` . W'. . e CL w0 DETECTOR SCHEDULE suite #. zO '>• t s.t, _., I ,t7G � � NO CHANGES B�. ht... \ Date: 2 t;j 0 o MONITOR SCHEDULE co N. NO CHANGES } OFFICE COPY z 3 Q Q FIRE ALARM RISER DIAGRAM w CC NO CHANGES / i L> BATTERY CALCULATIONS SILENT KNIGHT 5820XL / /IL/L:2575 CURRENT DRAW TO BE MEASURED AND / DWG REV. / BATTERY CALCULATION DOCUMENTED ON SW BEVELAND STREET obi, AS—BUILT DRAWINGS .f, ‘//,/""" DRAWN DRAWN BY: �,. SMB GiECKED BY:(1 [2>"�—.1 MGH FlLE NAME: FA.dwg DRAWING t FA-1 /OF DWGS IN SET: SHEET 1 OF 2 z.N 3 ® O I mm C W 8 51 1 2 0 5 ® 7 0 "1/.'''' e, Po I I I I / �F \ / 1 O u '1` ��. A — I -- ---�-- -- - -- �� I I I 1 ICF a 1l:F OFFICF co; ```�� \ 1 r.9,". ,aa Encl coal t� e,w� ins; lA+oz �.1 ``, - � \ $le 111.1 SUITE 13Q 1 15 CD l'irl -75 CD 4* EOL O© N-3 OFFICE ```I�', r CD N-3• SUITE 160 SUITE 150 SUITE 140 f.ONFF ENCE 75 CD �. OPEN OFFICE OFFICE OFFICE A,06 I p A..• /0/1 �I Y ,a:. 75 CD ��®©. �J n CL Po V%-cD 7,4r.' ��I ILe�I _ A10 \• z 1.111111111111111111111.11 5 1 1 I N-3 • ��si RArEO coaelooR �® �N-3 � �. U F- O _15 CD„o _ _ ririr_ 15 CD_ __ - 1 / � / w mi. C J '', J r ' '�' cr 9�� .st, 1 a�'� W Air ___J—ir r J- - ' 4 - IIJ _<, I �, f, 1f 'fr, Ii' .F I r..r,irfif! ,r._►ir!!ilml.ilm - �� ���It/� > O J � % I• il�f fffilf:��f1�Ifl�fl �`if � ��l I' I / 1�� q!ffffl�lbj ffff j1i��1 �'_ �� , p01. N�N m LLI�I r . I' o!. 1!G I!I i f!f'f f,•`f l.�'i 11 i-"--- , 1__L w O_I / •f1>Liffffflrl; ■ lr i ' f�, r . {�� �%.i �1 �� / ��� ��l U E --_-- ---- I - � Il III ►A 1,41 A co VA Id .MPIII = FAT . •...°A_II .4..1 IF , . . rr, 1 , ,,01 /lc \1 7/ 0141111111r. Ell it ,•'\ /•!,.111‘ Alit lip Aiiii21 i / 141 ii, 40 A lir LI IL A A AI A . A0 Al 14 /Clio WiTt.1 ■ 4 ■., A SJII v.--Lft-sadi Ili LAM MMJ 1;44111014 A A I , #,:-.•' M H FLOOR PLAN 0 8' 16' 32' ■ NORTH „ DWG REV. / DATE SCALE: 1/1 6” = 1 '-0" „ 0 03/25/15 SCALE: 1/16"=1'-0" DRAWN BY: SMB CHECKED BY: MGH FILE NAME: FA.dwg DRAWING j FA-2 OF DWGS IN SET: SHEET 2 OF 2 GENTEX CORPORATION Commander4 Series Selectable GCS/GCC Candela Evacuation Signals 24VDC Applications S E R I E S The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The GCS/GCC offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz and u► `; mechanical tone. All tones are easy for the professional to change in the field °� ',13- by using switches. The models are shipped from the factory in the temporal three alarm mode. fY -----_. r The GC Series has a very minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. �4 The Commander4 Series comes standard with the 4" mounting plate which the popular Super-Slide®feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander4 also features the patented Checkmate®- Instant Voltage Product Listings Verification feature which allows the installer to check the voltage drop draw SIGNALING _.rte, without removing the signal. ��°�`"'r The GC Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use APPROVED ? with fire protective systems and are warranted for three years from the date of LISTED I_I purchase. •ANSWL464 and ANSWL1971 Listed •FM Approved •CSFM: 7135-0569:122(GCC) Standard Features 7125-0569:123(GCS) • Nominal voltage 24VDC •MEA: 285-91-E • Tamperproof field selectable candela options of 15, 30, 75, 95,115& 150 Patents • Super-Slide®Bracket- Ease of Supervision Testing •7375,617 May 20,2008 • Checkmate®- Instant Voltage Verification • Unit Dimensions:6"(15.24 cm)x 2.6"(6.604 cm) Product Compliance • Synchronize strobe and/or horn with Gentex AVSM Control Module •NFPA72 'Americans with Disabilities Act(ADA) • Prewire entire system, install mounting bracket,then install signals •IBC/WC/RC • Documented lower installation and operating costs •City&State ordinances/Laws/Regulations • Input Terminals 12 to 18 AWG •Quality Management System is certified to: • Switch Selection for High or Low dBA IS09001.2006 • Switch Selection for 2400Hz or Mechanical Tone • Switch Selection for Continuous or Temporal 3 MEMBER • Tamperproof re-entrant grill ASSEMBLED IN • Surface mount with the GCSB(Gentex Ceiling Surface Mount Box) THE USA • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white GCS Series 24 Volt Ceiling Mount Selectable Strobe Model Part Nominal Candela Number Number Voltage GCS24CR 904-1213-002 24VDC 15, 30, 75, 95, 115, 150 GCS24CW 904-1215-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCR 904-1214-002 24VDC 15,30, 75, 95, 115, 150 GCS24PCW 904-1216-002 24VDC 15, 30, 75, 95, 115, 150 GCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Part Nominal Candela Reverberant dBA @ In Anechoic Room Number Number Voltage 10ft.perANSI/UL 464 dBA © 10ft. GCC24CR 904-1209-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCR 904-1210-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24CW 904-1211-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCW 904-1212-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 Model Designations: C =Ceiling Mount R = Red Faceplate W=White Faceplate All units are available in plain (no lettering). Plain units are non-returnable. GC24 Product Strobe Current Ratings (mA) Candela 15cd 30cd 75cd 95cd 115cd 150cd 24VDC 72mA 101 mA 167mA 200mA 214mA 286mA 24VDC (16-33 Volts) • UL Max' 120mA 120mA 200mA 220mA 290mA 321 mA GCC24 Product Horn Decibel and Current Ratings (mA) Minimum dBA @ 10ft. Minimum dBA @ 10ft. Regulated 24VDC Horn Mode per ANSI/UL 464 per ANSI/UL 464 Max.Operating (HIGH) (LOW) @ High Setting (mA) Temp 3 2400Hz 83 75 23 Temp 3 Mechanical 81 73" 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 NOTES: • Operating temperature:32°to 120°F(0°to 49°C). The GC Series is not listed for outdoor use. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. . • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). ' Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Mounting Super-Slide® 1, 3.SNAP COVER OVER ASSEMBLY VAN2.INSERT LOCKING SCREW \4�W� r � 1 ,i ,.........A, 'I all► ` - • nrh l Ey la JD- 1.SLIDE ONTO BRACKET Checkmate® Instant Voltage Verification Switch Locations DO NOT NWT -41\ 6'6:?Pr.., 1 ) Cf3 \-6\) • 0 n F F ac,21 B. b - II 0 i+ p • ��,I .- Ir., I ,5 010 MItkz, I I b O 0 IE-- , 0 , Z dd VI .■ f (calmness) LEIPII L'J I The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the Switch positions 1 and 2 in the down position to select device.Typically this would be done at the end of the line to isolated horn and strobe power inputs. Switch 3 selects confirm design criteria.Most measurements will be taken using between temporal or non temporal tone. Up is temporal. the S+and S-locations although access is provided to other Switch 4 selects between mechanical or high frequency locations. NOTICE:CARE SHOULD BE TAKEN TO NOT tone. Up is mechanical. Switch 5 selects between high - SHORT THE TEST PROBES. or low dBA. Up is high dBA. Conventional GC Series Wiring Diagrams UL Listed UL Listed Control Control Panel Signal Signal Panel Signal Signal s+ S+ S- Ho H- S+ S+ S- H+ H. s+ S+ S- H+ H- S+ S+ s- He H- Supervised O ised r „ G `►�, Supervised _SS SS , O. ® Signal Circuit £111111 11111 Signal Circuit „ \ O I"' 11111 ERESISTOORE END OF LINE \ �' II RESISTOR • ENet>f LINE RESISTOR • NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC.The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 29 pounds per carton Important Notice 551-0051-06 GENTEX necee matesumhave been re prepared by Genies Corporation as leg l advice and for should not be used purposes s only,are necessarily summary,and are not purported ie to serve or legal advice antl should not informational used as such. CORPORATION Genies makes no representations and warranties,relevant loo or implied.that fe ehese m.reguls are card rule and accurate,up-to-date.or incompliance with all relevant local,state and letleral laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding Fire Protection Products Group•www.gentex.com interpretation of laws,regulations antl rules and the application ot such laws.regulations and rules to p 9 parroular lad patterns.Each person s actruit�as can dleerently aeect the obligations that exist under 10985 Chicago Drive •Zeeland, Michigan 49464 applicable laws,regulations or rules.Therefore,these materials should be used only for intorntationa purposes and should not be used as a substitute lot seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure toad in reliance upon the information contained in this material. Genres Corporation reserves the right to make changes to the product data sheet at their discretion. GENTEX CORPORATION Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications The Commander3 Series is a low profile strobe and horn/strobe combination S E R I E S that offers dependable audible and visual alarms and the absolute lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of - — — 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30, 60, and 75 candela. • The Commander3 Series horn offers a continuous or synchable temporal three ( in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy E "11119' for the professional to change in the field by the use of switches. The GE3 Series has a minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. Product Listings The Commander3 Series is shipped with a standard 4" metal mounting plate SIGNALING which incorporates the popular Super-Slide®feature that allows the installer to test for supervision.The product also features a locking mechanism which secures the product to the bracket without any screws showing. ° .1 The Commander3 also features the patented Checkmate'- Instant Voltage LISTED 1-1 Verification feature which allows the installer to check the voltage drop draw • ANSI/UL 464&ANSI/UL 1971 Listed and match it to the blueprint. • CSFM: 7135-0569:122(GEC3-24& The GE3 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use GEH-24) with fire protective systems and are warranted for three years from date of 7125-0569:123(GES3-24) purchase. 7125-0569:129(GES3-12) 7135-0569:130(GEC3-12& Standard Features GEH-12) • Nominal voltage 12VDC and 24VDC • MEA: 285-91-E(GEC3-24&GES3-24) • 24VDC units have field selectable candela options of 15, 30, 60, 75& 110 580-06-E(GEC3-12&GES3-12) • 12VDC units have field selectable candela options of 15, 30, 60 & 75 Patents • GEH horn is available in 12VDC or 24VDC 7,375,617 May 20,2008 •• Unit Dimensions:5" (12.7 cm) high x 4.5"(11.43 cm) wide x 2.5"(6.35 cm) deep Product Compliance • Super-Slide®Bracket - Ease of Supervision Testing • NFPA 72 • Checkmate®- Instant Voltage Verification • Americans with Disabilities Act(ADA) • Synchronize strobe and/or horn with Gentex AVSM Control Module • IBC/IFC/IRC • Prewire entire system, install mounting bracket, then install signals • Quality Management System is certified • Documented lower installation and operating costs to:ISO 9001:2008 • Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime, whoop, mechanical and 2400Hz tone MEMBER • Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) ASSEMBLED IN • Surface mount with the GSB (Gentex Surface Mount Box) THE USA • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white • GEH 12VDC or 24VDC Low Profile Evacuation Horn - Model Number Part Number Nominal Voltage Reverberant dBA at In Anechoic Room 10ft., per ANSI/UL 464 dBA at 10ft. GEH12-R 904-1239-002 12VDC 62-82 100 GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 GEH24-W 904-1207-002 24VDC 62-82 100 GES3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Strobe Model Number Part Number Nominal Voltage Candela (ANSI/UL 1971) GES3-12WR 904-1235-002 12 VDC 15, 30, 60, 75 GES3-12WW 904-1237-002 12 VDC 15, 30, 60, 75 GES3-24WR 904-1321-002 24 VDC . 15,30, 60, 75, 110 ' GES3-24WW r 904-1319-002 24 VDC : 15,30, 60, 75, 110 GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA at In Anechoic Room (ANSI/UL 1971) 10ft., per ANSI/UL 464 dBA at 10ft. GEC3-12WR 904-1231-002 12 VDC 15, 30,60, 75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15, 30,60, 75 62-82 100 GEC3-24WR 904-1317-002 ' 24 VDC 15, 30, 60, 75, 110 62-82 100 GEC3-24WW 904-1315-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GE3 Product Strobe Current Ratings (mA) Model Designations: 12 VDC (8-17.5 Volts) 24 VDC (16-33 Volts) W =Wall mount Candela 12VDC UL Max' 24VDC UL Max' R = Red Faceplate W = White Faceplate 15cd 106mA 92mA 30mA 42mA All units are available in plain (no lettering). 30cd 131 mA 141 mA 35mA 58mA Plain units are non-returnable. 60cd 186mA 260mA 66mA 97mA 75cd 237mA 312mA 80mA 116mA ALERT bezel available for order 110cd 103mA 161mA AGENT bezel available for order GE3-12 Product Horn Current Ratings GE3-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 12VDC Minimum SPL Minimum SPL Regulated 24VDC Horn Mode at 10ft.,per at 10ft.,per Max.Operating a Horn Mode at 10ft.,per at 10ft.,per Max.Operating ANSVUL 464 ANSVUL 464 ANSVUL 464 ANSI/UL 464 (HIGH) (LOW) High Setting(mA) (HIGH) (LOW) High Setting(mA) Temp 3 2400Hz 76 dBA 69'dBA 29mA Temp 3 2400Hz 78 dBA 71'dBA 28mA Temp 3 Mechanical 75 dBA 68'dBA 26mA Temp 3 Mechanical 76 dBA 70'dBA 25mA Temp 3 Chime 62'dBA 60'dBA 13mA Temp 3 Chime 70'dBA 66'dBA 15mA Continuous 2400Hz 79 dBA 74'dBA 29mA Continuous 2400Hz 81 dBA 74'dBA 28mA Continuous Mechanical 78 dBA 72'dBA 26mA Continuous Mechanical 80 dBA 72*dBA 25mA Continuous Chime 63'dBA 61*dBA 13mA Continuous Chime 70'dBA 66'dBA 15mA Whoop 78 dBA 71'dBA 55mA Whoop 82 dBA 69'dBA 56mA NOTES: • Operating temperature:32°to 120°F(0°to 49 0C). The GEC3 and GES3 Series is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. 12VDC models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not • applicable when using the chime tone.The chime tone is always private mode). 1 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 7 Mechanical Temporal 3 ON ON ON ��■ /110]=1 Mechanical-Continuous OFF ON ON I=EN■ ■N I 2400Hz-Temporal 3 ON OFF ON 2400Hz- Continuous OFF OFF ON =[w■ El Chime-Temporal 3 ON ON OFF CE-I'■ ■. A- ]=) Chime-Continuous OFF ON OFF jAdi' Whoop ON OFF OFF [oi■ in CIF Whoop OFF OFF OFF - �1 NOTE: ® , �, • Switch Positions 1 and 2 in the OFF position to mt select isolated horn and strobe power inputs • Switch Position 6 ON =HIGH dBA 1*— • Switch Position 6 OFF=LOW dBA VI if::: ---Ar- Gentex Super-Slide® �-li -1 1 Gentex Checkmate® Instant Mounting Bracket L, Voltage Verification if Allows the installer to pre-wire It is often necessary to confirm the the system, test for system voltage drop along a line of devices.The supervision, remove the signal access holes are provided in the back of head until occupancy, switch !Mr the terminal block to allow the voltage to out Gentex signals without I, be measured directly without removing the changing mounting brackets device.Typically this would be done at the - and has locking edge connector 1111D l !i end of the line to confirm design criteria. for snap-in-place installation. Most measurements will be taken using if the S+and S- locations although access � ",,, is provided to other locations. �imiLalI! NOTE:Care should be taken to not short r • the test probes. / Candela selection slider -., switch. Depress center and slide switch to desire l- '� 1•1 brightness level. ! � l� II It. .� Break off pin and insert into hole at the bottom of ll II t ® r i IIthe selector to lock MODEI J ���'candela setting. Signal ,.AMEROM II 1 I! jJ, E�;. �, !,I' ;) must be removed from ' bracket and pin pushed -•� III : f ,I��. �4,/ forward from backside out Ip '< j r _:. of hole to change 1 00" ��� ' candela. �� To remove bezel, grip both sides of bezel and pull in a downward and outward motion. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control - Panel Signal Signal Panel Signal Signal S+ So S- Ha H- s+ s+ S- H+ H- S+ S+ S- H+ H- S+ s+ S- H+ H- Supervised ► ►r ra L. " r Signal Circuit Rim "I,"Supervised 9 S 0 0 . . ;, B B 9 J r , „ \ O I"' I"'1 END OF LINE Signal Circuit RESISTOR END OF LINE \ 0 RESISTOR END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT httpJ/www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. • When synchronizing the GE3 12VDC Series,the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GEH, GES3, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service (FM)and the California State Fire Marshal (CSFM). The notification appliance (combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton Important Notice 551-0050-06 G E N T E X These materials have been prepared by Gentex Corporation('Gentee'l for informational purposes only.are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local.state and federal laws,regulations and rules. The materials do not address all legal consderations as there is inevitable uncertainty regarding interpretation of laws.regulations and rules and the application of such laws.regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will rot be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion.