Plans RECEIVED UMPQUA PACIFIC CORPORATE CENTER Q• APR 14 2.015 TIGARD, OREGON ` / —'�+ CITY pF TIGARD • ,,,,,� BUILDING DtvlS{ON GENERAL NOTES DRAWING INDEX SYMBOLS LEGEND ^ i I. THESE DRAWINGS WERE PREPARED FROM BASE A0.0 COvER SHEET AND LIFE SAFETY PLAN r'�--+ ^1 DRAWINGS PROVIDED BY BUILDING OWNER AI.O DEMO PLAN DETAIL KEY '^ N e EVERY ATTEMPT HAS BEEN MADE TO ASSURE A2PJ CONST/ELECTRICAL/FINISH PLAN x «g s c THEIR ACCURACY.BAINBRIDGE DOES NOT TAKE A3.0 REFLECTED CEILING PLAN e ELEVATION KEY .E a RESPONSIBILITY FOR THE ACCURACY OF • N c e'" EXISTING BUILDING SHELL AND CORE ELEMENTS O'•$ SHOWN. © KEY NOTE 17:11 n 2. DO NOT SCALE DRAWINGS.CONTRACTOR SHALL //��\ a FIELD VERIFY ALL DIMENSIONS,CLEARANCES W m Y Le,5 AND CONDITIONS.NOTIFY DESIGNER OF ANT ;+If.I. a DISCREPANCIES PRIOR TO ORDERING CODE INFORMATION PROJECT DIRECTORY MATERIALS OR COMMENCING CONSTRUCTION. 3. CONTRACTOR TO PROVIDE DESIGN BUILD CONSTRUCTION TYPE I-A OWNER: UMPQUA BANK SERVICES FOR ALL MODIFICATIONS TO FIRE SUSPENSION SPRINKLED PACIFIC CORPORATE CENTER BUILDING MECHANICAL,ELECTRICAL AND FIRE OCCUPANGT TYPE B PROTECTION STSTEMS,IT IS 11-1E CONTRACTORS TOTAL 50.FOOTAGE 6.318 6610 SW CARDNAL LANE RESPONSIBILITY TO PREPARE AND SUBMIT OCCUPANT LOAD 63 DESIGN-BUILD DOCUMENTS FOR APPROVAL NUMBER OF EXITS 2 TIGARD,OR 91224 Ce SHOWING EXISTING AND NEW LOCATIONS OF CONTACT: CHRIS JOHNS W LIGHTING,INVAC,FIRE SPRINKLERS,SMOKE DETECTORS,EXIT SIGNS AND EMERGENCY PHONE: 503-268-6853 Z LIGHTING AND FIRE ExTINGUISHERS.ALL WORK W TO BE IN ACCORDANCE WITH THE LATEST DEFERRED SUBMITTALS DESIGNER: BAINBRIDGE. U EDITION OF BUILDING CODES AND STANDARDS. 4. CONTRACTOR TO COORDINATE WITH BUILDING I.2. MECHANICAL DESIGN 319 SRICAL DESIGN F" SW WASHINGTON,STE.914 1.1.1 OWNER ANY INTERRUPTIONS TO ELECTRICAL, 3. FIRE SPRINKLER PORTLAND,OR 51204 Q MECHANICAL,PLUMBING OR FIRE PROTECTION 4. LOW VOLTAGE PHONE:503-224-6681 SERVICES WHICH AFFECT THE OPERATION OF Ce 114E REMAINING PORTIONS OF THE BUILDING. 5. EGRESS ILLUMINATION CONTACT:RACHEL SCHUBERT O 0 ANT INTERRUPTION OF THE SERVICES ARE TO , BE SCHEDULED IN ADVANCE AND THEIR Ce KEPT TO A MINIMUM. 5. ALL CTONSTRUCTION SHOULD COMPLY WITH THE CITY' /��QI O O 2001 OREGON STRUCTURAL SPECIALTY CODE, OF'ITGARD V L- AND ALL LOCAL GOVERNING BUILDING CODES •• AND ORDINANCES. REVIEWED FOR CODE COMPLIANCE u 0 LL ce Approved: [ .-r ¢ 1 z OTC: It.-1---- J 6 Permit#: I�o�ol5 OO//O o o Address _40 flr _ , - •••�s •C , d O 3 d Suite#: t D Lciej 17- a B -la&me Data ���S Sheet Title: • �• CODE SHEET OFFICE COPY AND LIFE SAFETY PLAN Sweet-Tomatoes 11 ! il ' ! O IPJPPPPP e Xfoce��� �� -- -- Project Team: J °7;, � ' _ I 41114477,:,;151,1%,,!!i://///,i ;/a. --I�—fin "F;'; v //o r— /ii�� AB, RS 5 „ % ih • O Project Number: 5':,, 1., 11111—— - Ill 7,,' 1.."4 Date: 4/6/15 BSlICS r_ �:• Revisions: • "IIIIII III 11;.. 11111• I N EzIT PLAN DIAGONAL DISTANCE• VICINITY MAP LIFE SAFETY PLAN T''°' SCOPE OF WORK Ell carlr�PATH a'EGRESS TRAVEL• E feNORTEST roeSI eLE 3E Scale: PO • rAT•auao+.sr••n•i Sheet Number: A A0•0 L . P -- .- �-- Ull L____Ifir_ir ■ r■ (----- r (-----_---) .,,,,. zig ft! III jam% P m v vi r�._ I II /� / /.v,;, / �d�a j �,/,., /„/ jII I I I %/;/j , . /..„,. ///,? rL�' %%'� i ,i//.,,///,1:'? /, ,// / �/ •ii-i,viii I I , /,/i i,,i vi, .: Y74 v,Y/,f I I �,,V ,%////. I- Z II /,/��% „ w vii/•,i vi5, ,,, ,,, V�% i, : /iii, / I, LW i..%5, .; ; II ji / I- ce °C O I `\ O 2 ■ _� r t I I I u_ ° s • Q 1- z N • 1 ■ 06 o� 1 Q _1 De D00 U0 a00 3° �U � : � � ca Sheet Title: DEMO PLAN N DEMO ED PLAN 411 SCALE:I/V = I'O' DEMO PLAN/RCP NOTES KEY NOTES Project Team: I. DEMOLITION 15 NOT NECESSARILY LIMITED TO WHAT IS SHIOU.N ON THE DEMOLITION PLAN.THE INTENT IS TO INDICATE THE GENERAL SCOPE OF REMOVE CEILING ELEMENTS AS REQUIRED BY CONSTRUCTION, AB, RS DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE ❑ INCLUDING PROJECTION SCREEN.SALVAGE FOR REUSE. CONTRACT DOCUMENTS. 2. PERFORM AND COORDINATE ALL DEMOLITION AND RUBBISH REMOVAL IN Project Number: ACCORDANCE WITH BUILDING STANDARDS.SALVAGE ALL DEMOLISHED [] REMOVE SCREEN MURAL AND ARTWORK SALVAGE FOR REUSE. MATERIALS FOR RECYCLING WHENEVER POSSIBLE. 3. CONTRACTOR TO COORDINATE WITH OU.NER REGARDING ANY INTERRUPTIONS OF PRIOR TO DEMO MOVE POWER STRIP FROM WALL TO BE REMOVED TO El COMMUNICATIONS,ELECTRICAL,MECHANICAL,PLUMBING,OR FIRE PROTECTION RECEPTACLE ON ADJACENT WALL. Date: 4/6/15 SERVICES WHICH AFFECT THE OPERATION OF THE REMAINING PORTIONS OF THE FACILITY.ANY INTERRUPTIONS TO THESE SERVICES ARE TO BE SCHEDULED IN ADVANCE AND THE DURATION IS TO BE HELD TO THE ABSOLUTE MINIMUM. Revisions: 4. PROTECT SURROUNDING AREA DURING DEMOLITION.PATCH AND REPAIR ALL 0 DEMO EXISTING VCT IN STORAGE ROOM TO THIS POINT ONLY.PREP FOR CARPET. EXISTING WORK TO BE LEFT IN PLACE THAT IS DAMAGED DURING DEMOLITION. 5. AT WALLS TO BE REMOVED,ALL ELECTRICAL DEVICES,SWITCHES AND WIRING SHALL BE REMOVED AS REQUIRED BY CODE.RELOCATE SECURITY EQUIPMENT 0 RELOCATE LENEL PANELS PER OU.NER'S DIRECTION PER OWNER 6. EXISTING ELECTRICAL OUTLETS IN EXISTING WALLS TO REMAIN UNLESS NOTED OTHERWISE. T. PATCH AND REPAIR EXISTING ITEMS TO REMAIN WITH A WORKMAN LIKE TRANSITION TO NEW CONSTRUCTION. Scale: J/$' a J'-0' 8. SALVAGE ALL DOORS AND FRAMES FOR REUSE. DEMO PLAN LEGEND Sheet Number: EXISTING WALL OR PARTITION TO . REMAIN A ------' WALL TO BE DEMOLISHED /�1•O L / ` a 4 P Ask/__fe ..........: . �—I—ICI—I—I—'�',•,>iil�li:✓♦I�I�I� / • • • OFFICE •OFFICE I t 1 ■ ® ® OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE L ]V0 MU EME OFFICE algl O OFD I a FICE ICONE RM . 1 con( I 4_4 ..J I 0 17--- -1 .---r- 17--,,,z(i____(-- (-- .. y HALL ` j 2.4%.7 o$ ® .� // • E 1•F ►-1 11 ► �/ %i p e 11�I OPEN OFFI /� / j//•/ /w%,%'/%, ,a = :,7 —J-- ® /�///�� �i<:%/ %%�%i i j rte= !�i i 1 OFFICE , , /ice; r /,/ , -- --. _ /./..//��, , /;,ii, ,,,,,•• ,,. �'j , D j // �i%//ii�� / ii ii'iii•/L/h,/////4 LOBBY �� 7,'///// //,%, /i//' OFFICE /%" �% '/ ce 7// ,%%/,, * OFFICE / f% /!�. , Y///i, /, /,,,,,,/4 IN © �% •/i:�/ / U LW ■ ' �i��r h, II WELLNESS RCLOSET e / / j W • Vow 7L///, �r� / j IP lI © OFFICE I- /�/// <. IMII 9, — ce_ ELEC® 1 ® cc o � _ I 0� I'i U D z CZ _ - •III OFFICE • • <—' — n �__ P� n- — Q as _I �� a� 0 30 - - A C. 00 o N V) '0DCe 1- O CONSTRUCTION PLAN Sheet Title: SCALE:I/8' = 1'0' El) KEY NOTES CONSTR PLAN LEGEND 0 RELOCATED DOOR TOUCH-UP AS REQUIRED PLAN EXISTING WALL OR PARTITION TO REMAIN ■ NEW PARTITION TO UNDERSIDE CEILING,MATCH © PATCH VCT AS REQUIRED BY DEMO EXISTING WALL TYPE • NEW BASE FEED TO SYSTEMS FURNITURE.VERIFY © PROVIDE AND INSTALL FIRE RATED PAINTED PLYWOOD ON 5OUTI4 WALL LOCATION WITH DESIGNER PRIOR TO WO Project Team: WOW 15 DUPLEX OUTLET Q CUT FULL GLASS LIGHT INTO EXISTING DOOR TO BE RELOCATED AB, RS 41 VOICE/DATA QUADRAPLEX OUTLET MOUNTED- Protect Number: PROVIDE FULL STRING TO ABOVE © COORDINATE ELECTRICAL REQUIREMENTS WITH COINER D DEDICATED CIRCUIT El FLOOR BOX TO BE CAPPED IF EXISTS UNDER TABLE BASE Date: 4/6/15 CONSTRUCTION NOTES iii HOLD NEW WALL 4'FROM DOOR TRIM I. ALL DIMENSIONS FROM FACE OF FINISH LINO.WALL THICKNESS ARE NOMINAL UNO. Revisions: 2. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK.NOTIFY RELOCATE PROJECTION SCREEN PER OWNER OWNER OF ANY DISCREPANCIES PRIOR TO START OF WORK 3. ALL NEW PARTITION CONSTRUCTION AND BRACING TO MATCH EXISTING BUILDING STANDARD AND COMPLY WITH CODES(IBC/.MATCH EXISTING TO FORM SMOOTH TRANSITIONS.PATCH AND FINISH NOTES REPAIR EXISTING PARTITIONS AS REQUIRED FOR'AS NEW CONDITION.PREPARE FOR PAINT. 4. NOTIFY OlLNER'S REPRESENTATIVE OF FIRE STROBE,THERMOSTAT AND ALARM LOCATIONS) I. ALL WALLS,COLUMNS,AND SOFFITS TO RECEIVE NEW PAINT,COLOR TBD.CONFIRM WITH PRIOR TO INSTALLATION. OWNER IF DOOR TRIM TO BE PAINTED. 5. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION OF ALL FURNISHINGS,FINISHES, 2. THE SECOND FLOOR WILL ALSO RECEIVE NEW PAINT THROUGHOUT,COLOR TBD. BUILDING STRUCTURE,EQUIPMENT,AND SYSTEMS TO REMAIN AS REQUIRED.THE CONTRACTOR IS 3. AREA AT DEMOLISHED STORAGE ROOM TO RECEIVE NEW CPT-I.PLACE NEW CARPET Scete: 1/8' o II-0' ■ RESPONSIBLE FOR ANY DAMAGED DEEMED TO BE THE RESULT OF THEIR WORK THE TILES TO ALLOW SMOOTH TRANSITION FROM OLD TO NEW.PROVIDE NEW RUBBER BASE AS CONTRACTOR WILL COORDINATE CLEAN UP OF ALL AREAS AFFECTED BY DUST OR ANY NECESSARY.MATCH EXISTING.PROVIDE SUBMITTAL FOR APPROVAL. MATERIALS,BOTH DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT SO THAT 4. TOUCH UP WOOD BASE ON SECOND FLOOR ELEVATOR LOBBY. Sheet Number. WOOD THE SPACE 15 READY FOR OCCUPANCY. 5. PROVIDE el-FOLD DOORS AT CORRIDOR ALCOVE ON SECOND FLOOR CONFIRM S. ALL TELE/DATA AND A/V EQUIPMENT TO BE PROVIDED AND COORDINATED BY OWNER LOCATION WITH OU.NER. 1. THESE PLANS 5140W DESIRED ELECTRICAL AND DATA ONLY.CONTRACTOR TO USE EXISTING WHERE POSSIBLE.PROVIDE DESIGN BUILD SERVICES. 8. CONFIRM NUMBER OF CIRCUITS NEEDED AT NEW BASEFEEDS WITH MINER. FINISH LEGEND _ A2.O 5. MOUNTING HEIGHT FOR RECEPTACLES SHOULD BE 18'AFF UNO. 10. MATCH EXISTING COVER PLATES. CODE PRODUCT MANUFACTURER STYLE COLOR INSTALL CPT-I CARPET PATCRAFT MODERN GEOMETRY/24X24 TILE PRESTIGE 0015 QUARTER TURN 0 4 4 0 0 0 • /7/ P . = 1 10, ,...,,,,,,,,..., • ....., a is Lh I I I W.I 114, !bl AO 1 / %/%• /j % .t I �/ ir•%/.%•%% j//fizz fs///• / %j �// /i i. /i�•./i,. //////i N I %1// vv.'''.ii; iii• / ,.... ce =jik ,,,..,,,, ,..,,...„. ................./ / ! iii; 1� % /// I O/ // :. El oc J j I OJ Al mi �I II � � 1! I I I Q ~ a I II w I J o C6 lQ Q —. _� ao 0 o3O V W�_ ,---- t Sheet Title: REFLECTED N CEILING REFLECTED CEILING PLAN PLAN 0 SCALE:I/8' o I'0' CEN) RCP LEGEND PLAN NOTES Project Team: Q CAN LICsHT TO BE REMOVED I. THESE DRAWINGS REPRESENT GENERAL LIGHTING PLACEMENT AB, RS ONLY AND ARE NOT INTENDED TO DICTATE NUMBERS OF n EXISTING 2X4 TO REMAIN FIXTURES ON A CIRCUIT.COORDINATE ON SITE AS NECESSARY. j Pro ect Number: CONTACT DESIGNER OF ANY ISSUES. 2. RE-USE EXISTING CIRCUITING AS NECESSARY. RE-USE EXISTING r__ EXISTING 2X4 TO BE RELOCATED JUNCTION BOXES WHERE POSSIBLE. L_—J 3. REMOVE OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED TO MEET CODES. Date: 4/6/I5 RELOCATED 2X4 FIXTURE 4. MOUNT WALL SWITCHES AT 42'APP.OR MATCH EXISTING, COORDINATE LOCATION WITH OWNER 5. ANY WALL OR CEILING MOUNTED DEVICES OR CONTROLS Revisions: REQUIRED BUT NOT SHOWN ON THIS DRAWING ARE TO BE REVIEWED WITH OWNER/DESIGNER PRIOR TO INSTALLATION. 6. RELOCATE MECHANICAL AS NECESSARY.PROVIDE BALANCE TESTING IF REQUIRED. T. REPLACE ANY BROKEN/STAINED CEILING TILE IN AREA OF WORK,MATCH EXISTING. 8. CONTRACTOR TO VERIFY ALL BULBS AND FIXTURES ON THE SECOND AND THIRD FLOOR ARE IN WORKING CONDITION Scale: I/8' a 1'-0' s Sheet Number: A3.0 L • ■ WALL TYPE AS SGFIEDULED. ■ ALUTIM➢'T TRIM PIECE'GEE'Ill/I-I/1• N RETURNS.FINISH TO MATC1.WNJOL FRAMES. LINE OF BILL AO OCCURS. .L J 1.% d `TEOPRENE hi! 070EM mna ØWALL TO MUWON SCALE:Y . I'0• pe E--'LU 0 Z w J U LL L.1.1 O 1— ct 0 1- 3 6EOJR 1•AFRRION TO UNDERSIDE CF Z N • CUILDNG STRUCTURE WITH DIAGONAL n FRAMING MEMCERS•e'-0'OC.MIN ,�I EXISTING- - ••D CEILING ( W U O In REVEAL WITH CAULKING AT r+ Z .W1.4. DEFLECTION TRACK SOUND ATTETLATION AT NEW ALL,Tee. u O 0 V1 d V °¢C -�o U-CEAD Q L`LI W O U ►'r O. to GC 1= 1516'ce•cuT CD.ON COTH SIDES -. I- Sheet Title: l'4 3-Or'METAL STUDS•l.'OC. s►1 CONT�ACOUSTIC SEALANT DETAILS 1 ail FINISHED FLOOR QWALL TO CEILING SCALE:6' • l'0• Project Team: RS, AB Project Number: Date: 4/(o/IS Revisions: Scale: I/2 r I,_m• Sheet Number: A4•0 _ L__