Plans
SCOPE OF WORK SITE FIRE EQUIPMENT SYMBOL LIST i,O 0, I 6 r MODIFY EXISTING ADDRESSABLE FIRE ALARM SYSTEM TO INCLUDE ADDITIONAL SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT m HORN STROBES, AND STROBES. d n I FACP I FIRE ALARM CONTROL PANEL (EXISTING) FCI SELF-CONTAINED SURFACE MOUNT EXISTING w S 7100-2D 20.1'4 X 14.09'W X 4.55-D Y o Sip J aJ� ��RygM FCPS FIRE ALARM REMOTE POWER SUPPLY (EXISTING) SILENT 4 KNIGHT 16.0'HCON12 25.1Y XR3.0'D MOUNT EXISTING a co GENERAL NOTES p _J O.1,0 E-jtzi (NAC AND OCANDELA NOTED AT DEVICE) WHEELOCK 80' MIN TO LENS BOTTOM AFT SINGLE GANG VERTICAL 96" MAX TO TOP OF LENS AFF 19 6' MIN TOP OF LENS TO CEILING 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA yl STROBE - WHITE 80' MIN TO LENS BOTTOM MT WHEELOCK 72 AND NFPA 70, ARTICLE 760, POWER UNITED SYSTEMS. 5 SINGLE GANG VERTICAL 96' MAX TO TOP OF LENS AFT 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE (NAC AND CANDELA NOTED AT DEVICE) STW 6' MIN TOP OF LENS TO CEILING THAN ONE FLOOR SHALL BE RISER RATED. �C 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. •••• WP REPRESENTS WATER PROOF DEVICES m 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. C DENOTES CEILING MOUNT CITY OF TIGARD I '∎ 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTNING PROTECTION DEVICES. S 4„, 6. DEDICATED BRANCH CIRCUfT(S) AND CONNECTIONS SHALL BE MECHANICALLY J \� REVIEWED FOR CODE COMPLIANCE PROTECTED. 7. CIRCUIT "FIRE DALARM SCONCE CU MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS Approved: [ 4 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE OTC: (NFPA 72). 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION N y� -Cr %'� OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). Permit . '� 10. A RECORD OF COMPLETION SHALL BE PROVIDED D THE FIELD INSPECTOR Address: `1 r;�2 9):► ���� AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH SECTION 14.6.2.4 (NFPA 72). Suite #.;_. ` _ _ Bin Date: A.2 n • OFFICE COPY L,-, Li I- BATTERY CALCULATIONS SILENT KNIGHT 5495 _ w (1) STANDBY (HRS): 24 3RD FLOOR � 5 -4- > FIRE ALARM OPERATIONAL MATRIX ALARM TIME (MIN): 5 0 N Cr) PART / DESCRIPTION CITY STANDBY EA. STANDBY TOTAL ALARM EA. ALARM TOTAL T E NO CHANGES SK 5495 FIELD CHARGING POWER SUPPLY 1 0.0750 0.0750 0.2050 0.2050 N-9 HI TECH TI 1 0.0000 0.0000 0.8190 0.8190 U Q O CL N-10 NAC 10 1 0.0000 0.0000 1.5000 1.5000 W = N-11 NAC 11 1 0.0000 0.0000 1.5000 1.5000 1- = O TX N-12 NAC 12 1 0.0000 0.0000 1.5000 1.5000 _ O STANDBY AMPS = 0.0750 ALARM AMPS - 5.5240 2 N E Q STANDBY A-HR = 1.8000 ALARM A-HR - 0.4640 AMPERE HOURS REQUIRED = 2.2640 M W 20%DERATE = 2.7168 CO BATTERIES TO BE INSTALLED = 7 AMPERE HOURS _ Li- ADDRESS SCHEDULE - � ----)NO CHANGES ±f ONG REV. / DATE 0 03/26/15 FIRE ALARM RISER DIAGRAM NO CHANGES NOTIFICATION CIRCUIT SCHEDULE DRACBY: VOLTAGE DROP CALCULATIONS (NECKED 13Y: MGH CKT DEVICE LOCATION AREA FILE NAME: / pRCUIT TOTAL HIRE MIRE VOLT YOU ACCEPTED VOLT FANAME: ORIGIN AMPS DIST 9ZE DROP AT EOL DROP DROP x 9 N-9 HORN/STROBES, STROBES HI TECH FCPS/2 .819 415 14 2.087 18.31 YES 10.23 ORAYANG# N-10 HORN/STROBES, STROBES EXISTING FCPS/2 EXIST EXIST 14 EXIST EXIST YES EXIST N-11 HORN/STROBES, STROBES EXISTING FCPS#2 EXIST EXIST 14 EXIST EXIST YES EXIST FA-1 N-12 HORN/STROBES, STROBES _EXISTING FCPS/2 EXIST EXIST 14 EXIST EXIST YES EXIST ...END OF UNE METHOD - VOLTAGE DROP CALCULATIONS... iOFDWGSINSET: SHEET 1 OF 2 , I �� ow.w —Al r„...- ..rAi 0. z,,,,e v. ir Ir (� L����� ��is� SSG w o 0 COT NCE -i��© -F a a = COFFEE , /� I ,i--'<'' 00, - 13111 N-9.7 `, ' N-9.5 C ~ v -_ f I�' a ooM 1:itil 1 f OFFICE /�� T • i _ � 7 `� '�� (n : v J N OPEN OFFICE r � ��,� Z m r1-7412P IPM , 1,47.1r 1 1 )- 10 of., Advit clOP2 01 4, J A 1$ lige•A f I. ,n Lu .... , J 1 _ _ il,_ Id Lu U) �301� I I'' U LLI ¢ o oQ N-9.3 w ct 4 ®-- 115 CD Al �_ I -ice—� C LL 1, 7 7,7 WAI - Ar' CONFERENCE ® �I / I I •v_I. 5 CD i HS 1'15 9CD C \\) I MC REV. / DAM 0 03/26/15 01 OFFICE OFFICE 1302 DRAMN BY: -_� - FGC R CHECKED 8Y: MGH __ - rte -- FIE NAME:I ,F FA-1.dwg 7' '\) al FLOOR 3 _ 1 1 BRAYING ® SCALE: 3/32" = 1'-0" SCALE: 3/2"=1'-0" NOTE: PLENUM WIRE TO BE USED IN FA-2 PLENUM SPACES /OFDNCSINSET: SHEET 2 OF 2 00 COOPER Notification ED Strobe, Horn Strobe, and Horn Notification Appliances FIRE /111\ Ceiling - Wall Description: The Wheelock®ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. up 14% installation** - Save u to cost of installation The Wheelock®ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single O Sleek Modern Aesthetics appliance. Models with an audible feature 3 sound settings(90,95.. 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting ADC Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 10 8 Candela Settings ** it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed. The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra kij Universal Mounting Base '* secure installation, while the ceiling models provide a captivated Ceiling and Wall Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. Compliance Environmentally Friendly - UL 1971, UL 464, ULC, CSFM, FM Low Current Draw -ADA/NFPA/ANSI/OSHA - RoHS Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock®Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the"Regulated Voltage"range Compared to competitive models "'Patented "Compared to previous models NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their'Regulated Voltage Range'. -All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. •Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32•F to 120•F(0°C to 49•C)and maximum humidity of 93%(t 2%)UL 484(85%UL 1971). •Series Exceder horns are under UL Standard 464 for audble signal appliances(Indoor use only). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current* 24VDC/24FWR 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current' at Anechoic 99 dBA 24 VDC 12 VDC • Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Current' at Anechoic 95 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max Current' at Anechoic 90 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic ° -Model Regulated Voltage 99 dB 95 dB 90 dB '" Range VDC j HN 16-33.0 0.064 0.044 0.022 1 • • -N2.-..HNC 16-33.0 0.084 0.044 0.022 4r \� HN 8.0-17.5 0.047 0.026 0.017 ^� % / ''41(r\ , \ i .,. HNC 8.0-17.5 0.047 0.026 0.017, `.. \\ / UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Specification & Ordering Information Sync wl Model Strobe DSM or 12124 VDC* Mounting Candela Wheelock Power (4 Options Supplies K 0 y Horn Strobes w ra •0 HSR 15/1575/30/75/95/110/135/185 X X v UMB** o o HSW 15/1575/30/75/95/110/135/185 X X UMB** d HSRC 15/30/60/75/95/115/150/177 X X e8 UMB** 0 HSWC 0 15/30/60/75/95/115/150/177 X X v UMB** E Strobes o d STR 0 1511575/30175195/110/135/185 X X M UMB** ESTW r 15/1575130175195/110/135/185 X X c UMB** w STRC C 15/30/60/75195/1151150/177 X X kr UMB** E STWC N 15/30/60/75/95/115/150/177 X X to UMB** d) CO c i' Horn R 4-,• HNR V X X w UMB** C a • HNW V X X c UMB** W HNRC CO X X UMB** HNWC X X UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend ; �. 'Pill HN = Horn A =Agent Lettering ST =Strobe (Strobes only) '� J �+ = AL=Alert Lettering `� w f �. HS Horn Strobe C = Ceiling Mount (Strobes only) a P • W =White N =No Lettering +"%& R =Red (Strobes only) • / ) . Example 1: STRC=Strobe,Red,Ceiling Mount Example 2: HSR=Horn Strobe,Red,Wall Mount Example 3: HSW=Horn Strobe,White,Wall Mount IV 4 Example.Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering " ' '' le. .HSWC �j �-, 11 ='"tom ,:4,,::,,`- • • a P` Ai I kk 11; 0 0 \ . L' •1 ;,`� ., ;'•1i .. .I ` *UMB Contact Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 • troubleshooting and easy spot mounting options checking (wall models only) NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock® ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock®'s DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS NOWA WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 5/13 NJ Location 273 Branchport Ave. • Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com Cooper Notification is Wheelock" SAFEPATH' WAVES COOPER Notification